1. This warranty covers all defects in workmanship or materials for 1 The mechanical and electrical parts including labor costs contained in this Haier product for a period of 12 months from the date of purchase commercial or rental application the warranty is 90 days 2 The sealed system and compressor contained in this Haier product is for a period of 5 years from the date of purchase excluding labor costs after the initial 12 month period In commercial or rental use the additional limit ed compressor warranty is for 1 year and 9 months excluding labor costs after the initial 90 days period You must keep and be able to provide your original sales receipt as proof of the date of purchase Who is covered The original retail purchaser of this Haier prod uct What will be done Haier will repair or replace in your home any mechanical electrical part or the compressor which proves defective in normal household use for a period of 12 months Haier will repair or replace excluding labor costs the sealed system and compressor parts only for an additional 4 year period How can you get service 1 Contact your nearest Haier authorized Service Depot For the name of the Service Depot nearest you contact Haier at 877 337 3639 2 All service must be performed by an authorized Haier Service Depot 11 THIS WARRANTY COVERS UNITS WITHIN THE CONTINENTAL UNITED STATES CANADA AND PUERTO RIC
2. O AND DOES NOT COVER e Damages from improper installation e Damages in shipping e Damages from misuse abuse accident alter ation lack of proper care and maintenance e Damages from service by other than an authorized dealer or service center e Labor service transportation and shipping charges for the removal of defective parts and installation of a replacement part beyond the initial 12 month period THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequen tial damages Some states do not allow the exclu sion of incidental or consequential damages so this limitation may not apply to you Some states do not allow limitations on how long an implied warranty lasts so this limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state IMPORTANT Do Not Return This Product To The Store If you have a problem with this product please contact the Haier Customer Satisfaction Center at 1 877 337 3639 DATED PROOF OF PURCHASE MODEL AND SERIAL REQUIRED FOR WARRANTY SERVICE IMPORTANT Ne pas retourner cet article au magasin En cas de probleme avec cet article veuillez contac
3. PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL User Manual Model HPE07XC6 Guide de I Utilisateur Modele HPEO7XC6 Manual del Usuario Para Modelo de HPEO7XC6 Before operating this Air Conditioner please read these instructions completely H ie Quality Innovation Style English A Word From Haier Thank You for buying a dependable energy saving and easy to operate HAIER air conditioner This manual contains useful information for you to maintain operate install and safely use your air condi tioner Your air conditioner cleans cools and dehumidifies the air in your room to provide you with the ultimate level of comfort Please read instructions carefully before using the product Also do not forget to fill out and mail the Product Registration Card Product Registration Record Your Model and Serial Number Attach the sales receipt to this guide and keep for future reference Model and serial number can be obtained from the serial label which is on your air conditioner For all your service calls during the warranty period the following information will be needed Serial Number nm Date Of Purchase cc ns Dealers Address Lc nn Dealers Phone Number nas TABLE RECEPTACLE AND FUSE TYPES RATED VOLTS 125 60 250 60 AMP x o A D ES or ES o La A TIME DELAY FUSE Plua Plua Plua or circuit braker English SAFETY PRECAUTIONS WARNING Follo
4. Speed Control has 3 settings High Timer Control Medium Low Auto turn off With machine in fan mode press timer button to select number of hours you would like the unit to run in air conditioning mode until it automatically shuts off Auto turn on With machine powered off press timer button to select number of hours until you would like the unit to automatically start running in air conditioning mode Timer Timer set Controls Used for adjusting the timer and thermostat The default display is room temperature In cooling mode When 4 or y button is pressed the set temperature is displayed and may be adjusted After 15 seconds the display will revert back to room temperature Temperature is only adjustable in Cool and Heat mode The time is adjustable between 1 and 12 hours Note By pressing both Temp Timer Set buttons at the same time the display will toggle between Celsius and Fahrenheit NOTE Wait for 24 hours to turn on air conditioner if the unit has been tilted for any reason This is for the oils and the coolants to settle and level off 1 After a normal shut down wait for 3 minutes before restarting the unit so as to complete the compressor cycle 2 Use an 115v 15 amp outlet for the air conditioner Do not use any other electrical appliances on this line or you may trip the fuse Use a dedicated line for this air conditioner Do not place the air conditioner in direct sunlight or close to any heating appli
5. an Speed Power i Control Mode Control Fan Speed Control Room Temp Set Temp e e El O Timer Timer Temp Adjust Timer Temp Power Control The power control turns the unit on and off Warning Light Condensed water may accumulate in the unit If the internal tank becomes full the Warring Light will shine and the unit will not operate until the unit has been drained Mode Control The Mode Control has three settings Cool The settings are adjusted with Mode Control but ton A light will indicate which setting is currently being used Cool Mode When cool mode is selected the indicator light will shine green During the cooling mode the air is cooled and hod air is exhausted to the outside air through the exhaust tube Adjust fan speed air through the temperature to suit your desired com fort level Dehumidify Fan Note The air exchange hoses must vent outside the room when using cool Mode Dehumidify Mode When Dehumidify mode is selected the indicator light will shine orange Air is dehumidified as it passes through the unit without being in full cooling mode The fan will operate in Medium speed Fan speed is not adjustable in Dehumidity mode Set Controls Fan Mode When Fan mode is selected the indicator light will shine yellow Air is circulated throughout the room with no cooling Note unit does not need to de vented in Fan mode Fan Speed Control The Fan
6. ances eg baseboard heaters stoves etc Operate on a flat surface only Keep the unit free of any obstructions such as drapes curtains blinds etc Keep unit at least 1 foot away from the wall Check and clean the filter once every week for highest efficiency NOTE Do not use unit without filter If the unit is not being used for a long period of time remove the plug from the water drain pipe and drain out any condensed water N UN A 0 00 When turning on the unit for the first time after plugging it into an electrical outlet the unit will start in a low fan cool mode The temperature reading out on the LED will be the current room temperature When turning on the unit during regular usage it will remember the last shut off set ting If you want to operate the air conditioner as a dehumidifier then adjust to dry mode Setting The Temperature To set the temperature press the or the key to raise or lower the temperature The tempera ture can be raised or lowered in the cool or dry mode The temperature cannot be adjusted in the fan mode Fan Speeds There are 3 adjustable speeds in the cool and fan mode Low Medium amp High In the dry or dehumidification mode the fan will only operate at low speed On Off Time Set The air conditioner has a 1 12 hour on off built in timer To delay the start time for 1 12 hours at 1 hour intervals simply press the time set key and then press the or key to adjust the sta
7. nd or discolor your air conditioner e Always use a soft cloth dampened with water or a mild soap and water solution to wipe the front of the cabinet Wipe dry with a soft cloth Storage e To store your air conditioner when not being used for a long period of time drain con densed water using the drain pipe Remove exhaust hose clean the filters cover with plastic bag and store away English Trouble Shooting If air conditioner does not operate e Check if unit is plugged in The plug may have come loose e Check if the electrical wall receptacle is of proper voltage e Check if the circuit breaker needs to be reset or if the fuse needs to be replaced e Check if the unit is in Off mode e l the warning light is on drain the water drain pipe by removing the plug Air conditioner working but room not cooling e Room may have appliances that produce heat Use an exhaust fan to remove excess heat e Check exhaust hose for proper installation e Redirect the airflow Remove any obstacles e All doors and windows need to be closed so that cool air does not escape the room e Air filter may be blocked or may need cleaning e Unit BTU may be too low for the required cooling area e On extremely hot amp humid days air conditioners may take a little longer to cool e Drain the water drain pipe by removing the plug e Unit may be in fan or dry mode Put air conditioner in cool mode 10 English Limited Warranty
8. r or wash basin SAVE THESE INSTRUCTIONS English Table Of A Word From Haier Product Registration Safety Precautions Advantages coococccconcccon o Parts and Features Assembly and Installation Operation ooccococconco Product Specification Care and Cleaning SIMAO radianes Trouble Shooting Warranty Information Contents Advantages of this Model 1 This model is easy to operate The electronic control panel has a timer thermostat three cooling speeds three fan speeds and one speed dehumidification function dry 2 The unit has a unique design which evaporates the water Therefore no condensation tank is necessary thus avoiding you to have to wake up in the middle of the night to empty the bucket and turn on the unit 3 Easy to install window kit is included which consists of the exhaust hose 2 hose adapters the window panel kit and window panel adapter 4 Full directional casters are included to help the unit to be moved in almost any area 5 The filter screen is designed for easy accessibility of the filter 6 Portable air conditioners are easy to store when not in use Parts and Features CON OORA Y N Control Panel Air Deflector Left Right Front Panel Handle Hole Castor Screen Filter Air Intake Evaporator Air Outlet Heat Exchange 9 Air Intake Condenser 10 Power S
9. rt time Note that the unit has to be plugged in to an electrical outlet for the timer to operate To automatically shut off the unit press the time set key while the unit is running and then press the or key to adjust the shut off time The auto shut off switch operates in all 3 modes Cool Dry amp Fan NOTE The temperature can be set between 60 F to 89 F English Product Specification Voltage and Frequency Input Power Cooling Capacity Moisture Removal pints day Coolant Timer Operating Temperature Range Unit Dimensions WxDxH inches Net Weight lbs approximate Exhaust Hose 115V 60Hz 850 W 7000 BTU 60 R 22 12 Hours 64 F 100 F 17 3 32 X 15 3 4 x 30 5 16 435 mm x 400 mm x 770 mm 66 lbs 5 Feet Care and Cleaning Guide e Always unplug your air conditioner before cleaning e Air filter needs to be cleaned at least once a week for your unit to operate at optimum efficiency Slide out the filter from the back by pulling on the tab The filter may be washed or vacuumed Remove the excess water from the filter by gently shaking the filter This will remove dust and particles trapped in the filter After cleaning reinstall the filter DO NOT use your air conditioner without the air filter in place e To clean the cabinet DO NOT use harsh chemicals abrasives ammonia chlorine bleach concentrated detergents solvents or metal scouring pads Some of these chemicals may dissolve damage a
10. ter le Centre satisfaction client de Haier au 1 877 337 3639 UNE PREUVE D ACHAT DATEE LE NUMERO DU MODELE ET LE NUMERO DE SERIE SONT OBLIGATOIRES POUR BENEFICIER DE LA COUVERTURE OFFERTE PAR LA GARANTIE IMPORTANTE No Devuelva Este Producto al Establecimiento Compra Si tiene problemas con este producto por favor p ngase en contacto con el Centro Haier de Atencion al Cliente en el 1 877 337 3639 PARA EL SERVICIO DE GARANTIA SE REQUIERE PRUEBA DE COMPRA FECHADA No DE MODELO Y No DE SERIE Made in China Haier America New York NY 10018 Printed in China Issue December 2005 Part AC 9999 47
11. upply Cord 11 Water Drain Front Rear 11 English Assembly and Installation Accessories Include O Plastic panel 2 pieces Window Panel adapter 1 piece Screws 4 pieces Heat Exhaust hose connector 2 pieces o Heat Exhaust hose 1 piece O AUN O1 1 Push the round Window Panel Adapter through the rear of the Plastic Panel Line up the holes and tighten the Adapter with 4 screws that are included in the kit Tighten screws from the front 2 Adjust the Plastic Panel to the width or height of your window and tighten the 2 screws that are attached to the panel 3 Install the Window Plastic Panel into the window If necessary use duct tape to better secure the panel 4 Connect exhaust hose to the unit by inserting the hose connector that is attached to the hose into the exhaust See Illustration A 5 Move the unit to the window extend the hose and attach the other end of the hose to the window Align the tabs on the hose and window panel adapters and fasten them together 6 Plug into wall outlet to get ready for operation NOTE Use on Single Outlet Circuit Only Hose Connector Exhaust Hose Hose Connector Operation Control Panel English Display Mode Indicators Display Warning Light High Med L wO Power Mode F
12. wing these basic precautions will reduce the risk of fire electrical shock injury or A 1 A 2 death when using your air conditioner Air conditioner must be connected to proper electrical outlet with the correct electrical supply see table previous page Proper grounding must be ensured to reduce the risk of shock and fire DO NOT CUT OR REMOVE THE GROUNDING PRONG If you do not have a three prong electric receptacle outlet in the wall have a certified electrician install the proper receptacle The wall receptacle MUST be properly grounded Do not operate air conditioner if power cord is frayed or otherwise damaged Also avoid using it if there are cracks or abrasion damage along the length plug connector or if the unit malfunctions or is damaged in any manner Contact an authorized service for examination repairs or adjustments DO NOT USE AN ADAPTER OR AN EXTENSION CORD Do not block airflow around the air conditioner Also the exhaust hose should be free of any obstructions Always unplug the air conditioner before servicing it or moving it Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is oily or sulphurous Avoid any chemicals coming in contact with your air conditioner Do not place any object on the top of the unit Never operate the air conditioner without the filters in place Do not use the air conditioners near a bathtub showe