Home

Dyna View Manual - Dyna Pro Dynamometers Ltd

image

Contents

1. Ta Graph Separation ME pos d lx I I xu Air Correction SAE J1349 Corrected P FR 4 c a Cc a Left Hand Axis Label Graph box 2 A I A F R io Left Hand Axis Label Graph box 3 Speed mph 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 pine Speed rpm Bottom Axis Label Dyna View Screen Icons Open Dyno Run from File Show three graphing boxes Selected Dyno Run Properties Graph box 3 Common Left Right axis Clear all Dyno Runs from Graph Graph box 3 Auto Scale both axis Exit Dyna View and returns to the Make Run Screen mh n Gul Quick Print Show single graphing box Turn On Off Multi graph Separations 3k Graph box 1 Common Left Right axis Graph box 1 Auto Scale both axis Open Graph identifier 1 Show two graphing boxes Open Graph identifier 2 Graph box 2 Common Left Right axis Open Graph identifier 3 Graph box 2 Auto Scale both axis Open Graph identifier 4 SRY BFXOL Displays Run Data at the cursor position Graph Identifier raph box 1 Right Hand Axis Label Graph box 1 Correction Factors Graph box 2 Right Hand Axis Label Graph box 2 Graph box 3 Right Hand Axis Label Graph box 3 If you place your Mouse Cursor over any of the screen Icons or Dyna View controls a windows help message box will be displayed d
2. Auto detect Display Save s Manual Open Default Save As Manual Open Default If you select this function you will be prompted by Jess If you click Yes then all graph settings Axis Labels correction factors scales etc will be saved as the graph default values Are WOU sure vou want to save these settings as Default Any time that you open a Dyno Run for viewing it will always open with your default graph settings 10 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Drop Down Menus Engineering Units i Dyna Pro Run Viewer File Properties Special Functions Hep Left mouse click on Engineering Units Set up to show the Engineering Units zl a x Engineering Units Set up Custom k Set up drop down menu 4 mn File Title The In brackets part tells you what units have been selected i e Metric SAE Japanese or Custom settings Engineering Units Set up Engineering Units Set up International Standards You may wish to choose a Standard Unit set up Metric SAE or Japanese If this is the case then just left mouse click one of Engineering Unit Selection the options and then all the Unit Fields will be updated t Metric f SAE f Japanese Power bhp Distance Fons jkm If you prefer to work in the Units that su
3. poop be i iy Corredion SAE DUMP Conectad Power pesest Move the mouse cursor up or down d oimeue ra E the list then left mouse click on the E p Data Channel that you wish to aem display Ex Temp 4 C 5000 6000 T000 8000 9000 10000 11000 12000 13000 14000 Engine Speed rpm All Graph Axis Labels can be changed to any available Data Channel This includes Left Hand Right Hand and Bottom Axis Labels See Below Gees Spec He Paste Egneeneunes Downie He x 5 e jf kW msi mj 5e5 j Cem EDAM ue Cent 7 X L 2 DUMP Destin x i mw m E wt Joe Date Type Leonean Moe Pree Pose db Cie Nowe Jine Deilige 1 No Poen 1 hti San Mor te De ree Xn ie C wgefas Mise Diim Am i c 393 he Cen Ty Sete CawetioeFaho SEN m oe 1 Dra tet Peleo SP Pos 15 m Pvt Fela gt wi Mre bus Ste 108024 t WSEM Capen fieri 1 Ne CH 306 HAB HUM motes Tun N SC idis MU CH HAB MC Aw Perseus Wier Suman LES CHAI RAS Dyna Pro Ltd Graph Box Control Buttons The Graph Box Control Buttons are arranged as groups of 3 buttons the first group of 3 all relate to Graph Box 1 the second
4. Auto Scale Axis Graph Box 3 Auto Scale Axis A Dyna Pro Run Viewer DEAR File Properties Engineering Units Special Functions Help l 4 21 Be E rel Smoothing Correction Factor SAE 31349 DJHP Correction P Date File Name Title Time DataType File Location Max Power Power Max Torque Torque No 1 RGV500 Single Gear Base Run 4th Ger 02 12 20 14 18 47 FSF M C Program Files Dy 128 98bhp 10606 9 64 27 1047811pm 1 Notes fne re Temperature 18 4 C Air Pressure 1011 7mBar Humidity 42 2 0 972 97 85 N otice t h at t h e L ef t an d R gh Ax S S a re n OW bot h mee scaled from 0 to 130 i www dynapro co uk Dyna Pro Ltd GM ee we LES This Icon appears to be pressed 2 E a o 91354 enbioL 9000 Engine Speed rpm 20 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk 3 Dyna Pro Run Viewer DEAR File Properties Engineering Units Special Functions Help l x 4 csi HE Tei Smoothing Correction Factor SAE 31349 DJHP Correction V File Name Title Time DataType File Location Max Power n Max Torque Torque No 1 RGV500 Single Gear Base Run m ENGI sp 2 2 14 18 47 FSF M C Program Filesi Dy 128 98 bhp 64 27 Ft lb 10478 1 pm 1 neuen anga Giu I M Temperature 18 4 C Air P
5. Dyna View as just a viewer package then you will be returned to your windows desktop but if you are using Dyna View from within Dyna Run you will be returned to the Make Run hl This Icon has the same effect www dynapro co uk Drop Down Menus Properties i Dyna Pro Run Viewer File Properties Engineering Units Special Fu w Show Motes Info Show Maximise Left mouse click on Properties to show the properties drop down menu Auto detect Display Save 4s Manual Open Default Shown Notes Info If this function has a tick to the left of it then the Notes list box will be shown else the Notes list box will be invisible File Properties Engieering Lins Specs Functions Help Sex sa wfuibe lae EEE bp moj pron gt 3 wu Ela eux eem FETA T concn Title Data Type Fie Location MaxFowes Pom MakTeque Tore No Title Tme Data Type File MaxFowe Power Tore amp mem ae 153211 MSFM C Program Fles Dy 11474 bhp 13439 AG AT Fi 110521 1 E TN 153211 a 114 74bhp 121237 pm 4642 110521 mpm 1 Notes 44 86 Repeataboty Dpr Av Temperature 25 C Air Pressure 1694 2mBar Humidity 45 8 CF 0 996 RAD 94 86 Area Power 2099 69 Area Torque 1322 63 i Dyna Pro Ltd E www dynapro co uk Dyna Pro Ltd 113 ondio E A
6. exe Head Only data media i e CD DVD ehicle Type Mileage Vehicle Make Registration No though you can modity the Gr aph VehideModel 7 Vehicle Year Properties Dialog data you will not be able to Save this data back to the data nope media that is was Read from Peak Power bhp 109 26 14004 2 rpm Air Temperature 16 1 C Peak Torque Ft lb 42 38 11898 6 rpm Air Pressure 998 8mBar To Save the edited data fields either DJHP Corrected Power Humidity 58 9 96 Log Started at 1932 4 rpm 18 22 mph Relative Air Density 97 19 Log Finished at 154028 rpm 141 04 mph CF Standard SAE 1348 Log Run Time 34 169 Seconds Correction Factor 0 985 left mouse click on the Save Icon or drop down the file menu and select Save or Save amp Exit Area Under Graph Power 2755 39 Area Under Graph Torque 1248 81 When you select Save a warning message will be displayed showing Are you sure you want to save this edited Dyno Run File Select Yes to Eddy Brake PAU Data Parameters Step amp Hold PAU Mode Save Step Hold Start Speed 3000 rpm Step Hold Finish Speed 15000 rpm StepiHold Step Value 1000 StepiHold Tolerance 50 rpm Step Hold Hold Time 0 5 Seconds Start Point 7500 RPM Finish Point 12000 RPM Base Point 10 Rear Wheel Diameter 620 min Rear Wheel Inertia 0 2914 Run Notes 23 Dyna Pro Dynamometers Ltd Dyna View V2 User Ma
7. o qi33 enbioL Air Chreeetion SAE J1349 DJHP PERI Power 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 Engine Speed rpm 19 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk 3 Dyna Pro Run Viewer DER File Properties Engineering Units Special Functions Help l x 4 al IE At AE ARIE ILI Smoothing Correction Factor SAE J1349 DJHP Correction IV Date T File Name Title ime DataType File Location Max Power Power Max Torque Torque No 14 RB Repeatability 15 10 20 15 37 11 MSF M C Program Files Dy 114 95 bhp 13406 rpm 46 54 Ft lb 10982 4 1 Notes 14 R6 Repeatability Dpr Air Temperature 25 C Air Pressure 1008 2mBar Humidity 45 8 0 996 94 86 3101 05 1462 91 Notice that the Left and Right Axis s are NOT wwwdynapro couk Dyna Pro Ltd scaled the same The left hand side is scaled 0 to 130 and the right hand side is scaled 0 to 65 2 This Icon Appears to be raised Power bhp 91354 enbioL Air Correction SAE J1349 Corrected Power 10000 11000 12000 13000 14000 Engine Speed rpm Auto Scale Graph Axis If one of the Auto Scale Axis buttons is selected shown below this will Auto Scale the Graph Box data You can control the Auto Scale Axis on each individual Graph Box LES Graph Box 1 Auto Scale Axis 2 Graph Box 2
8. www dynapro co uk The Show Graph mode Show Graph button This dialog box is a standard Microsoft Windows dialog box you can change folders create folders rename files and change directories etc Left mouse click on any of the Dyno Run Files the File Run Properties window will update with the file selected and a graph preview will be shown If you try to preview an invalid Dyno Run File it will display a message informing you that the file is not a valid Dyno Run File Double left mouse click or pressing the Open button will then open the file in Dyna View Recent Files 3 Dyna Pro Run Viewer Properties Engineering Units Special Functions Help Open Graph r2 tefl stl sbin e rintaa The Recent Files option will show you a list of the last 15 Recent Files C Program Files Dyna Pro Dynamometers Logged Data Example Datal13 R6 Repeatability Dpr L 7 C Program Files Dyna Pro DynamometersiLogged DataYExample DataM 1 GSXR1100 Nitrous Ing Dpr B Dyn O H u n f 1 I es t h at h ave b ee n O pe n ed a n d V ewed C Program FilesiDyna Pro Dynamometers Logged Data Example 10 Busa Dpr C Program FilesiDyna Pro Dynamometers Logged Data Example Data 9 RG5S00 Map Change Dpr Run Data Properties FS Remove this Dyno run F4 Remove AL Runs id C Program FilesiDyna Pro Dynamometers Logged Data Example Datal8 RG500 Map Change Dpr L 7 Print Set
9. Dyno Run Files Please be aware that this is a general software manual covering all aspects of the Dyna View V2 software some of the features functions menus and system configurations may not be available to the user as a result of those features being specific to a particular model of Dynamometer Keep this reference manual in a convenient place as it is a valuable reference source in the use of the Dyna View V2 Conventions Used In This Manual To make reading and understanding this manual more convenient certain naming conventions have been used throughout this publication Convention Used NOTE The Note icon indicates a special point of notice for the operator The Caution icon indicates a potential hazard to the dynamometer equipment or to the vehicle being tested Follow all procedures exactly as they are described and use care when performing all procedures The Warning icon indicates potential harm to the person performing a procedure and or the dynamometer equipment Italic Italic hyphened items are names processes and menu names Bold Bold Highlighted items that you can select on within the software including buttons menus check boxes and radio buttons Technical Support For technical support and assistance please contact Dyna Pro Dynamometers Ltd at 44 0 1256 363063 or an appointed agent Dyna Pro Dynamometers Ltd can also be contacted by mail at Unit 18 Sherrington Way Lister Road Industrial Es
10. 8000 9000 10000 11000 12000 13000 14000 Engine Speed rpm 12 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Air Fuel Limits Properties Air Fuel Graph Display Limits 8 The Air Fuel Limits Properties dialog box allows the user to set an upper and Air Fuel Graph Limit Properties ower Air Fuel Annotation Line to the graph 13 5 Air Fuel Upper Limit 12 5 Air Fuel Lower Limit Cancel Save amp Exit If Show Air Fuel Annotations has a tick to the left of it Dyna View will show the Upper and Lower Air Fuel annotation Lines euoN Upper and Lower Air Fuel Annotation lines 4000 5000 6000 T000 8000 9000 10000 11000 12000 13000 14000 Engine Speed rpm Atmospheric Condition Warning The Atmospheric Condition Warnings dialog box allows the user to set atmospheric parameters which will then warn the user if these limits have been exceeded when opening and displaying Dyno Runs Enable Channel Description Limit Units Air Temperature B Each of the 5 parameters can be enabled disabled and there warning limits changed A Atmospheric Condition Warnings X Air Pressure lt If the Always show the above Atmospheric differences when opening Relative Air Density 1 BADZ Dyno Runs is selected then every time that you Open a Dyno Run it
11. PRNL PERS EIAS gosse p PRAE Ee USE ioc e Correction SAE JINS hap Co aud Pour Dyna View with Notes List Box Dyna View without Notes List Box Show Maximize If this function is selected a tick to the left of it the displayed graph will be maximized over the full screen it will not show the Data List Box or the Notes Box File Properties Engineering Lins Special Functons 5 Bla Ij SITE ii eeh contre EDS 3 once Dyna Pro Ltd 91723 enbiet Display Maximized Multi Gear Auto Select If Multi Gear Auto Select has a tick to the left of it then the system will read the Dyno Run data and then determine if it was a Multi Gear run or a Single Gear run if it determines that the Dyno Run was a Multi Gear run then it will automatically change the Bottom Axis label of the graph to either Road Speed Time or Distance depending on what you have selected in Auto Detect Display options Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Auto Detect Display ie Dyna Pro Run Viewer File Engineering Units Special Functions Help Select the Bottom Axis label you require when a Multi Gear Run has been el v Show Notes Info detected Show Maximise You can select between Road Speed Time or Distance
12. RGV500 Single Gear Dpr 5 RGVSDO Muli Gear Dpr Select the file you wish to view then click on the Open button 6 RGV500 Multi Gear Dpr This dialog box is a standard Microsoft Windows dialog box you can change folders create folders rename files and change 11 G5xR1100 Nitrous Ing Dpr directories etc 12 step test 13 Repeatability Dpr 14 R6 Repeatability D pr There is also two other Open File Dialog Modes which are lS activated by the Show Notes button and the Show Graph Show Graph Files of Type Dyno Run File dpr aad butto n Open Dyno Run File File Run Properties The Show Notes mode Show Notes button pressed File Name Run Date Log Type deg This dialog box is a standard Microsoft Windows dialog box you can change folders create folders rename files and change directories etc Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Open Dyno Run File 1 RGV500 Single Gear Dpr 2 RGV500 Single Gear Dpr 3 RGV500 Single Gear Dpr 4 RGV500 Single Gear Dpr 5 RGV500 Multi Gear Dpr 6 AGY 500 Multi Gear Dpr 7 RG500 New CDI Dpr 8 RG500 Map Change Dpr 3 RG500 Map Change Dpr 10 Turbo Busa Dpr 11 GSXR1100 Nitrous Ing Dpr 12 step test Dpr 13 R6 Repeatability Dpr File Run Properties Title File Name Run Date Log Type PAU Mode Max Power Max Torque Run Time Wheel Inertia Max rpm Air Temp Air Pressure Humidity Air
13. group of 3 all relate to Graph Box 2 and the third group of 3 all relate to Graph Box 3 These buttons allow the user to control how many Graph Boxes are displayed there scaling functions and there Axis Locking functions Graph Box Control Buttons File Properties Engineering Units Special Functions Help Fe Graph 1 Graph Box 2 Graph Box 3 Controls Controls Controls 18 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Display Multiple Graph Boxes You can display up to three Graph Boxes with Dyna View You can change the Left and Right Graph Axis Labels on each displayed Graph Box The Bottom Graph Axis Label is relative to all the Graph Boxes displayed You can add these additional Graph Boxes by left mouse click on the appropriate Icon buttons as follows Show single graphing box Show two graphing boxes Show three graphing boxes la Locus 90 T dem gj es nd m pis jo banten BAL 11388 IHP ie de ae rn ine ER Ji trate dueehmhaen ALT Y iP Corin des Sie x sua JR tradu A mew z s eR Dats ype 1 essen mS 1 Mes I S Jean n ar I aM urere P x econ Fandy bre en poni 2 3 1 5 I 7 7 Noks Repenasirripr Ar Terperserc 23 27 Ar Pressure WOtleter Curmekysdi
14. option must be selected before you can use the Quick Print button Icon Print Ctrl P Print Options 3 Dyna Pro Run Viewer IM Properties Engineering Units Special Functions Help Open Graph F2 Recent Files b pape elie Select this function to open the Printing Options menu shown below From this menu you can select or deselect items that will be shown on the printed graph Run Data Properties FS Remove this Dyno run F4 Remove All Runs F3 Print Set up Print Options Print Preview Print This option is also available from within the Print Preview screen Ctrl P Printing Options Printing Options Select or Deselect the required Check Boxes for the print options that you require Print max Power Torque and Engine Speeds v Print with Company Logo S dak SURES When you have finished click on the Save amp Exit button Cancel Save amp Exit Print Preview 7 Dyna Pro Run Viewer WIE Properties Engineering Units Special Functions Help Open Graph F2 Recent Files Ee Run Data Properties FS Remove this Dyno run F4 Select this function to show printing preview of what you are about to Print Remove All Runs F3 Print Set up Print Options Print Ctrl P Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Print i Dyna Pro Run Viewer EM Properties Engineering U
15. 6 Area Properties Menu F7 Area Annotations Enable Disable F8 Air Fuel Display Menu F9 Air Fuel Annotations Enable Disable F11 Climate Warning Menu F12 Exit Product Brochure EEE sse Left mouse click on Product Brochure to show Dyna Pro products parts l AE Dyna view Manual Smoothing and news Title Kev Stoke Function Keys ie prece eroe i NOTE That Adobe Reader must be installed on the user s computer a to be able to view this file About Units Special Functions BE Dyna View Manual Fi Kev Stoke Function keys Left mouse click on About to show the Software and Hardware Version Information Produce Brochure Dyna Pro Dynamometers Taking the guesswork out of the performance equation 5 15 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Screen Functions Data List Box The Data List Box shows information from each of the displayed Dyno Runs please note that a maximum of 4 Dyno Runs can be shown at any one time The Data List Box shows you a Graph Identifier Dyno Run name time and date that when it was done file location and its peak power and torque File Hame Date DataType File Location Power Powerat Torque Torque at No 14 R6 Rep
16. Correction SAE J1349 Run Notes Hide Notes File Name f 4 RB Repeatability D pr Show Graph Files of Type Open Dyno Run File Lookin 10 Example Data m Load Cell Data 4 1 RGV500 Single Gear Dpr 2 RGV500 Single Gear Dpr 3 RGV500 Single Gear Dpr 4 RGV500 Single Gear Dpr 5 RGV500 Multi Gear Dpr 5 RGV500 Multi Gear Dpr 7 RG500 New CDI Dpr 8 RG500 Map Change Dpr 3 RG500 Map Change Dpr 10 Turbo Busa Dpr Dyno Run File dpr None Entered 14 R6 Repeatability Dpr 15 10 2005 15 37 11 Manual Start Finish Multi Gear MSF M No Load Mode Active 115 2 bhp amp 13417 74 rpm 46 62 Ft Ib 10982 46 rpm 7 935 Seconds Not Used 14249 8 rpm 25 C 1008 2 mBar 45 8 RAD 94 86 Correction Factor 0 996 DJHP Corrected Power File Run Properties Title File Name Run Date Log Type PAU Mode Max Power M ax Torque Run Time Wheel Inertia 11 GSXR1100 Nitrous Ing D pr 12 step test Dpr 13 R6 Repeatability D pr 14 R6 Repeatability Dpr e Note File Name Hide Graph Files of Type Power bhp Open Dyno Run File 1 RGV500 Single Gear Dpr 2 RGV500 Single Gear Dpr 3 RGV500 Single Gear Dpr 4 RGV500 Single Gear Dpr 5 RGV500 Multi Gear Dpr 5 RGV500 Multi Gear Dpr 7 RG500 New CDI Dpr 8 RG500 Map Change Dpr 3 RG500 Map Change Dpr 10 Turbo Busa Dpr Dyno Run File dpr Air Pressure Max RPM RAD Correction Factor Air Temp Humi
17. Delete File From Computer WARNING to permanently delete the blue Highlighted Dyno Run from the Graph and from your Hard Drive this will also clear its data entries from the Data List Box The message box shown below will be displayed to confirm that you want to permanently delete this file Use this function with care as once deleted it is gone forever Data Deletion WARNING e Are you sure that you want to completely DELETE this file From your computer Notes List Box J The Notes List Box gives you extra data about the Dyno Run that has been highlighted in blue from the Data List Box Notes 4 RGV4500 Single Gear Dpr Air Temperature 19 C Air Pressure 1011 6mBar Humidity 4 4 CF 0 973 RAD 97 65 Base Run Sth Gear x EF s F LE This data includes any notes that you or the dyno operator entered before or after commencing with the Dyno Run and also includes Dyno Run Name The Air Temperature from when the engine was run on the dyno The Air Pressure from when the engine was run on the dyno The Humidity from when the engine was run on the dyno C F Air correction factor this is dependent on what air correction factor was selected RAD Relative Air Density Area Under Graph for Power Area Under Graph for Torque Front amp Rear Sprocket sizes EBK Range Dyno s only Rear Wheel Diameter EBK Range Dyno s only 17 Dyna Pro Dynamometers Ltd
18. Designed amp Manufactured In The UK Dyna View V2 Software User Manual Advanced Dyno Data Viewing Software www dynapro co uk Dyna Pro Dynamometers Ltd United Kingdom Tel UK 44 0 8000 4321 68 Tel Int 44 0 1256 363063 E mail support dynapro co uk Table of Contents INTRODUCTION CONVENTIONS USED IN THIS MANUAL TECHNICAL SUPPORT DYNA VIEW DISPLAY SUMMARY DYNA VIEW SCREEN ICONS DYNA VIEW CONTROLS AIR CORRECTION FACTORS DATA SMOOTHING DJHP CORRECTION DROP DOWN MENUS FILE DROP DOWN MENUS PROPERTIES DROP DOWN MENUS ENGINEERING UNITS DROP DOWN MENUS SPECIAL FUNCTIONS DROP DOWN MENUS HELP SCREEN FUNCTIONS DATA LisT Box NOTES LisT Box CHANGING THE GRAPH AXIS LABELS GRAPH Box CONTROL BUTTONS DISPLAY MULTIPLE GRAPH BOXES COMMON LEFT amp RIGHT GRAPH AXIS AUTO SCALE GRAPH AXIS GRAPH BOX SEPARATION CHANGE THE GRAPH Box SIZES CURSOR READ OUT DISPLAY ZOOM IN UNDO THE ZOOM DATA PROPERTIES DIALOG IMPORTANT NOTICE ERROR MESSAGES DYNA PRO END USER LICENSE AGREEMENT INDEX BW C9 C9 25 26 28 Introduction Welcome to the Dyna Pro Dynamometers Software manual for Dyna View V2 Please carefully read the installation instructions for this software before commencing with the actual software install This software manual gives the user detailed information on program features functions menus and system configurations required for viewing
19. Dyna View V2 User Manual www dynapro co uk Changing the Graph Axis Labels e Dyna Pro Run Viewer File Properties Engineering Units Special Functions Help ENS You can change all the Grap h Axis e ex w e dak Eae EEE f Smoothing Conection Factor SAE J1349 DuHP Conecton I Labels to any standard Data ENT Tie sims Hi File Date Time DataType File Location Max Power Power Max Torque Torque No 14 RB Repeatability 15 10 20 15 37 11 MSF M C Program Files Dy 114 95 bhp 13406 rpm 46 54 Fb 10982 4 1 Ch an n el i Or if any addition Sensors were install on the system they will also be made available For Example TPS Thermocouple Sensors Pressure 14 R6 Repeatability Dpr Air Temperature 25 C Air Pressure 1008 2mBar Humidity 45 8 C F 0 996 94 86 3101 05 1462 91 M www dynapro co uk Dyna Pro Ltd a den mcn es rc idu m a an If you put your mouse cursor over any o hum beds of the Graph Axis Labels you will _ a NERONE NUN ee ee AMEN MINE NNNM RE NAR Ju notice that it changes from an Arrow HE 05 0 UI Pointer to a Hand pointer dede bed e 9 ki e LESE ne oe eee f When this occurs you can then left DU peter mouse click and this will display a qu DUM con id Pop Up Menu with a list of all Distance Meters available Data Channels
20. a E A E 2 Important 25 1 rO UCO AEE E 1 s m 3 o 3 K Wido oc 14 M ulti Gear Auto Select 9 M ulti graph Separation eennen 21 N Note ISU oo MR 17 Open 4 8 PE ODDS 7 mala POM CW RT PE 7 PROC oS UD 1 R Recent al cc RE 6 REMOVE All Runs eeeenmmeen 6 16 Remove This Dyno 6 16 Return e T 14 Run Data Properties eene 6 16 S sid 3 Save As Manual Open Default 10 Seen FUNCIONS osse uou Ud RS qp 16 Show 9 Shown Notes ATO 9 3 T Iiic 14 Table ago 3 TCH Cal SUD OTE Flat 1 Z Zoom In Undo the Zoom eemmme 23 28 www dynapro co uk Compiled Date 1 January 2011 Dyna Pro Dynamometers Ltd reserves the right to change specifications without notice 2011 Dyna Pro Dynamometers Ltd All rights reserved www dynapro co uk Dyna Pro Dynamometers Ltd United Kingdom Tel UK 44 0 8000 4321 68 Tel Int 44 0 1256 363063 E mail support dynapro co uk
21. ata Properties Dialog Drop Down M enus 24 Data Properties Dialog 1 24 Delete File From 17 ON 7002 OO 3 Display ultiple Graph 19 UE COP GE CUO 3 Drop Down M CRAUS RC EV CV QU 4 Drop Down Menus Engineering Units 11 Drop Down M enus Help sseenne 14 Drop Down M enus lt 9 Drop Down Menus Special Functions 12 Dyna Pro Dynamometers 1 Dyna VIEW 3 Dyna View Display 5 2 Dyna View Key Stroke Function List 15 E E a 3 End User License 26 Engineering Units Set up eesee 11 Error M essaggs ssseeeeeeeeneeennnnennnn nnne nnn nns 25 ESCAPE KEV 14 zi 8 F uite nA co 14 15 G Graph Box Control Buttons eene 18 Graph Box Separation eene 21 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual
22. d RARIUS 1001 14087 Noka Shh Aepemtastrpige Ar 23 27 Ar Pressure Wetlmfer 4545 1 00 1 1 I oue nrama Dyna Pro Lid Single Graph Box Double Graph Box Triple Graph Box Common Left amp Right Graph Axis If one of the Common Left Right Axis buttons is selected shown below this will lock the Left and Right Axis to be the same on both sides of the Graph Box You can control the Common Left Right Axis on each individual Graph Box 4 Graph Box 1 Common Left Right Axis 2 Graph Box 2 Common Left Right Axis 3 Graph Box 3 Common Left Right Axis 29 Pro Run Viewer BEE File Properties Engineering Units Special Functions Help l x amp 8 Smoothing Correction Factor SAE J1349 DJHP Correction V File Name Title Date Time Data Type File Location Max Power Power Max Torque Torque No My 14 95 Repeatability 15 10 20 15 37 11 MSF M C Program Files Dy 114 95 bhp 13406 rpm 46 54 109824rpm 1 Notice that the Left and Right Axis s are both scaled the same 0 to 130 Notes 44 R6 Repeatability Dpr Air Temperature 25 C Air Pressure 1008 2mBar Humidity 45 8 C F 0 996 RAD 94 86 3101 05 1462 91 www dynapro co uk Dyna Pro Ltd 4 This Icon appears to be pressed 2 a gt
23. dity Run Notes omn Cancel 5000 Engine Speed rpm File Run Properties PAU Mode Max Power Max Torque Wheel Inertia 11 GSXR1100 Nitrous Ing Dpr 12 step test Dpr 4 13 R6 Repeatability Dpr 2 EXC epeatability Dpr e Note File Name Hide Graph Files of Type Power bhp 5000 4000 14 R6 Repeatability Dpr Dyno Run File dpr IU EET Air Pressure Air Correction SAE J1349 Title None Entered 14 R6 Repeatability Dpr 15 10 2005 15 37 11 Manual Start Finish Multi Gear No Load Mode Active 115 2 bhp amp 13417 74 rpm 46 62 Ft Ib 10982 46 rpm 7 935 Seconds Not Used 14249 8 rpm 25 C 1008 2 mBar 45 8 File Name Run Date Log Type Run Time Max rpm RAD 94 86 Correction Factor 0 996 Air Temp Humidity DJHP Corrected Power Run Notes pen Cancel 8000 9000 10000 Engine Speed rpm 6000 7000 Air Correction SAE 41349 11000 ee ee ee D 1 1 D DJHP Corrected Power 12000 13000 14000 L This Icon has the same effect as File Open Dyna Pro Dynamometers Ltd Dyna View V2 User Manual By Left Mouse Click on any of the Dyno Run Files the File Run Properties window will update with the file selected Double Left Mouse Click or pressing the Open button will then open the file in Dyna View pressed 9134 L qi34
24. eatability 10 15 2005 15 37 11 M5SF M C Program FilessDuy 114 07 bhp 13226 7 rpm 46 62 1 817 3rpm 1 13 A6 Repeatability 10 15 2005 15 36 47 MSF M C Program Files Dy 114 38 bhp 1339 2 rpm 46 55 Ft lb 108426 2 The Data List Box can do much more though if you Left Mouse Click on one of the Dyno Runs listed it will Highlight that Dyno Run on the graphs and Highlight the data in blue in the Data List Box 3 Dyna Pro Run Viewer File Properties Engineering Units Special Functions Help el Lu 8 ra Ela Ej E Smoothing Correction Factor SAE J1349 DJHP Correction IV FileName Date Time DataType File Location Max Power Power MaxTorque Torque No 1 RGV500 Single Gear Base Run 4th Gear 02 12 20 14 18 47 FSF M C Program Files Dy 128 88bhp 10606 S8 rpm 64 27 10478 1 rpm 4 RGV500 Single Gear Base Run 5th Gear 02 12 20 14 50 18 FSF M C Program Files Dy 12338bhp 105152 pm X 55165Ft lb 10434 3 pm 2 4 RGV500 Single Gear Dpr Air Temperature 19 C Air Pressure 1011 6mBar Humidity 40 4 C F 0 973 RAD 97 65 Base Run 5th Gear www dynapro co uk Dyna Pro Ltd Double left mouse click in the Graph Area to undo the Highlighting 2 z 2 5 s 7 o id lt 9 H 4 1 9000 Engine Speed rpm Dyna Pro Run Viewer You can also right mouse click on the Dyno Run in t
25. escribing to you what this Icon or Control will do Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Dyna View Controls Air Correction Factors Air Correction Factors can be selected from the drop down menu box you can choose between five internationally accepted climate correction Correction Factor 2338 factors Maz Power These corrections adjust the power figures according to the current SAE J1349 climatic condition i e Air Temperature Air Pressure and Humidity They DIN 700200 will compensate the power readings for engine performance from day to 120 1585 day irrespective of the climatic conditions when the engine was tested 50 1269 5A It is strongly recommended that None should not be used as this could lead to inconsistent results as climatic changes occur during the day The correction settings for this function will always be displayed and printed in the bottom right of the primary graph None No Air Correction Factor Standard SAE J1349 American Standard but used the world over DIN 700200 German Standards ISO International Organization for Standardization EEC European Standards ISA Standards for Automation Air Correction Factors in most cases should only be applied to Normally Aspirated Engines and not to Turbo Charged or Super Charged engines In these cases please select the None option Data Smoothing The data Smoothing control allows the dis
26. he Data List File Properties Engineering Units Special Functions Help aj elx amp File Name Title Date Mi 1 RGY500 Single Gear Base Run 4th Gear 02 12 20 4 RG v500 Single Gear Base Run 9 Box and this will show a Cursor drop down Menu d 29 Left mouse click on Remove This Dyno Run to delete the blue 3 Highlighted Dyno Run from the Graph this will also clear its data entries from the Data List Box 14 18 47 Remove this Dyno run Remove all Dyno runs Run Data Properties Notes 4 RGV500 Single Gear Dpr Air Base Run 5th Gear Make this Dyno Run system Reference Delete File from Computer WARNING fl www dynapro co u Left mouse click on Remove all Dyno Runs to delete and clear all Dyno Runs from the graphs this will also clear all data entries from the Data List Box This Icon has the same effect as above Left mouse click on Run Data Properties to show the blue Highlighted Dyno Run properties window Please see later for use of Data Properties Dialog 16 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk eD Once a Dyno Run has been Highlighted in blue in the Data List Box this Icon has the same effect as above Make this Dyno Run system Reference this function only works for Dyna Run please refer to Dyna Run Manual for more details on this function Left mouse click on
27. it you then from each of Torque Fu Atmospheric Pressure mBar the headings pull down the drop down menu and select the Rotational Speed pm Temperature jc Units you require speed mph Presse oy xd The Options at the top will now automatically select Custom Time Seconds Angular Rotation degree v Distance Short Meters Gear Ratio m mph When you have finished click on the Save amp Exit button Cancel Save amp Exit 11 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Drop Down Menus Special Functions 7 Dyna Pro Run Viewer Fie Properties Engineering Units zl S ie 2 Area Under Graph Properties F5 Show Area Line Annotations FF File Mame T 14 Eispestabilo Left mouse click on Special Functions to show the Special Functions drop down menu Special Functions include calculating the Area Under Graph upper and lower Air Fuel line annotations Atmospheric Condition Warnings and a Calculator Air Fuel Limits Properties F w Show Air Fuel Annotations Atmospheric Condition Warnings Fil Calculator Notes 14 R6 Repeatability Dpr Area Under Graph Properties ru Men Under Graph Properties The Area Under Graph Properties dialog box allows the user to set a ower xX Area Under Graph Properties Data axis point an upper p di axis
28. ke Function Keys to open a PDF File that es allows you to print out the Key Legend Strips for placing above the function view enel Ft Smoothing keys on your keyboard Title Key Stoke Function Keys Praduce Brochure That Adobe Reader must be installed on the user s computer About to be able to view this file Function Key Key Stroke Mask Key Legend Strips for 4x3 and 3x4 function key arrangements Print out these Function Key masks and place on keyboard above the Function Keys Copyright 2007 Dyna Pro Ltd 301 Key strokes are a convenient way to navigate around the software without the need for using the mouse The Dyna Run and Dyna View software both accept the use of key strokes for all common tasks Dialog windows Message Boxes Menu s etc have also got further controls Tab Key Pressing the Tab Key will move the Data Cursor position to the next logical input box Return Key Pressing the Return Key will has the same effect as press the OK button Save and Exit Button Escape Key Pressing the Escape Key within any dialog window will close the window without saving any data that you have entered 14 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Dyna View Key Stroke Function List F1 Help F2 Open Graph F3 Clear All Graph Data F4 Remove Selected Graph Data F5 Selected Graph Properties F
29. move the cursor data along by 10 steps at a time ie Dyna Pro Run Viewer Seles File Properties Engineering Units Special Functions Help eu amp 2 amp Mes pe kellale Ez E te Smoothing Correction Factor SAE J1349 DJHP Correction IV File Name Title Dae Time Data Type File Location MaxPower Power MaxTorque Torque No 14 Repeatability 15 10 20 153711 MSF M C Program Files sDy 114 95 bhp 13406 rpm 46 54 Ft lb 10982 4 1 13 RE Repeatability 15 10 20 15 36 47 MSF M C Program Files Dy 114 79 bhp 13448 2 rpm 46 4 Ft lb 10965 9 rpm 2 13 R6 Repeatability Dpr Air Temperature 25 2 C Air Pressure 1008 3mBar Humidity 45 4 C 0 996 94 79 3102 1 1463 87 tl www dynapro co uk Pro Ltd 120 110 Power 83 i i e gt 4133 enbsoL TWO Engins Speed rpm 3 EISE ES OREL AF 42 25 feecees esses pee ie AN A F Ratio 12 31 RM D A 2 AUF Lower er he 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 Engine Speed rpm 22 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Data Cursor Read Out Zoom In Undo the Zoom Zooming is the process of using the mouse to select new extents of the graphs grid Any individual Graph Box ca
30. n w numbers that relate to other self proclaimed Industry Standard dynamometers These numbers are related to an estimation of Engine Crank Power fay T arque Torque at Ma Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk lf DJHP Correction option box is NOT Ticked the Power and Torque data displayed is the True Rear Wheel power being transferred to the dynamometer True Wheel Power will always read lower than crank estimated power The correction settings for this function will always be displayed and printed in the bottom right of the primary graph Drop Down Menus File E Dyna Pro Run Viewer le Properties Engineering Units Special Functions Help Open Graph F2 Recent Files Run Data Properties F5 Remove this Dyno run F4 Left Mouse Click on File to show the file drop down menu Remove All Runs F3 Print Set up Print Options Print Preview Print Ctrl F Exil Open Graph ie Dyna Pro Run Viewer iE Properties Engineering Units Special Functions Help Open Graph Recent Files Run Data Properties F5 Remove this F4 Left Mouse Click on Open Graph to show the Open File dialog window Remove All Runs F3 Print Set up Print Options Print Preview Print Ctrl F Standard Open File Dialog Window 1 RGV500 Single Gear Dpr 2 AGY500 Single Gear Dpr 3 AGY500 Single Gear Dpr 4
31. n be zoomed in on and then zoomed in on again Zooming can also be done over multiple Graph Boxes if required To Zoom 1 Press the Left Mouse Button and hold down whilst dragging the cursor to select the new extents 2 Release the Mouse Button To Undo the Zoom Press the Z key or use the popup menu Right Mouse Click to select the Undo Zoom menu item When you have Zoomed in on a graph you can use the bottom and side Scroll Bars to adjust the position of the zoom Data Properties Dialog If you have selected to open a Graph Properties dialog window see above for how to do this you can now view additional Dyno Run information and even add delete or modify certain parts of the data If you change any of the data fields you will need to save the changes before leaving the Data Properties Dialog 1 Selected Graph Properties File Engineering Data Fields that are coloured Light m amp Blue can all be modified or edited File Properties File Name 34 Step 1000 3000 to 15000 hold 0 5 Sec Title Step 1000 3000 to 15000 hold 0 5000 All other data fields are for reference Date 08 01 2007 Time 12 38 19 Run Type MSF M Gear Ratio Multi Gear and cannot be changed by the user File Location CAProgram FilesiDyna Pro DynamometersiLogged Data Example DataiLoad Cell Data NOTE If you have opened any Dyno Customer Notes R hi h h b d f Customer Name User Code uns wnic ave een opene rom
32. namometer Model and Accessories used to produce the Dyno Run File Error Messages If when opening a Dyno Run File you get a message box displayed showing an error message GOR 3 this is caused normally by an invalid or corrupted Dyno Run File 20 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Dyna Pro End User License Agreement YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING THIS PRODUCT IT CONTAINS SOFTWARE THE USE OF WHICH IS LICENSED BY DYNA PRO DYNAMOMETERS LTD TO ITS CUSTOMERS FOR THEIR USE ONLY AS SET FORTH BELOW IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS OF THIS AGREEMENT DO NOT USE THE SOFTWARE USING ANY PART OF THE SOFTWARE INDICATES THAT YOU ACCEPT THESE TERMS GRANT OF LICENSE Dyna Pro Dynamometers Ltd the Licensor grants to you this personal limited non exclusive non transferable non assignable license solely to use in a single copy of the Licensed Works on a single computer for use by a single concurrent user only and solely provided that you adhere to all of the terms and conditions of this Agreement The foregoing is an express limited use license and not an assignment sale or other transfer of the Licensed Works or any Intellectual Property Rights of Licensor ASSENT By opening the file package containing this software you agree that this Agreement is a legally binding and valid contract agree to abide by the intellectual propert
33. nits Special Functions Help Open Graph F2 at e Recent Files Run Data Properties FS Remove this Dyno run F4 Remove All Runs F3 Options menus Print Set up Print Options Print Preview Print Exit 7 Dyna Pro Run Viewer i Properties Engineering Units Special Functions Help Open Graph F2 Recent Files Run Data Properties FS Remove this Dyno run F4 Remove All Runs F3 Screen Print Set up Print Options Print Preview Print Ctrl P Dyna Pro Dynamometers Ltd Dyna View V2 User Manual The Print Preview will display a representation of what you are about to print if you want to change any print setting then go to the File drop down menu and select Print Set up Select the Print option to print the displayed document Select Exit to leave Print Preview without printing You can also Zoom in on the displayed graph by holding the Left Mouse button and dragging a window over the area that you wish to enlarge release the mouse button when done You can also use the bottom and side scroll bars to adjust the zoomed position If you wish to Un Zoom then right mouse click and Select Undo Zoom from the cursor drop down menu This will print the document according to how you have set up the Print Set up amp Print This Icon has the same effect Wiltz Efi This function will end your session with Dyna View if you are using
34. nual www dynapro co uk Data Properties Dialog Drop Down Menus There are only two drop down menus in the properties dialog window These are File and Engineering Under the File Menu you will see Save This will save your edited Dyno Run file Save amp Exit This will save and then exit from the Properties Dialog Exit This exits the Properties Dialog Under the Engineering Menu you will see Aux Channel Name Editor E Channel Name Editor Aux Channel Name Editor File Name This dialog box allows you to change the name of the Auxiliary Data Channels Active Channel Name Units Active Exhaust AR Active Exhaust2 A amp R Active Oil Presure Pressure Active Fuel Presure Pressure Click Save amp Exit when you have completed your changes Active ExTemp1 Temperature Active ETemp2 Temperature Active ExTemp3 Temperature Active ExTemp4 Temperature Cancel Save amp Exit Data Properties Dialog Icons Ej Save This will save your edited Dyno Run file hl Exit This exits the Properties Dialog Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk 24 Important Notice Please be aware that some Functions and Menu Options described above may or may not be available on the Dyno Run File that has been opened Some Functions and Menu Options are dependent on the Dy
35. ons Help Open Graph F2 Recent Files b Right mouse click on Remove this Dyno Run to delete the blue Highlighted Dyno Run from the Graph this will also clear its data entries from the Data List Box Run Data Properties F5 Remove this Dyno run ila La NEL Please see later for use of Remove this Dyno Run function in the Data List Box Print Set up Print Options C h apte Print Preview Print Ctrl P Remove All Runs 7A Dyna Pro Run Viewer mie Properties Engineering Units Special Functions Help Open Graph F2 Recent Files gt E Select this option to clear all currently opened Dyno Run File data from the Graphs Run Data Properties FS Remove this Dyno run F4 Remove All Runs This will also clear all of the data entries from the Data List Box Print Set up Print Options Print Preview Print ra This Icon has the same effect Ctrl P Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Print Set up i Dyna Pro Run Viewer IM Properties Engineering Units Special Functions Help Open Graph F2 Recent Files Run Data Properties FS Remove this Dyno run F4 Select this function to set up your printer defaults Paper size Orientation Quality etc EXE Em The Printer dialog box options will vary depending on what printer you have installed Print Options Pri Previow This
36. ore ENTIRE AGREEMENT This License Agreement sets forth the entire understanding and agreement between you and Dyna Pro Dynamometers Ltd supersedes all prior agreements whether written or oral with respect to the Software and may be amended only in a writing signed by both parties Dyna Pro Dynamometers Ltd Unit 18 Sherrington Way Lister Road Industrial Estate Basingstoke Hampshire United Kingdom RG22 4DQ 27 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk A POUT 14 15 Air Correction Factors vr PE nh c Rei 3 Air Fuel Limits lt 13 Area Under Graph 12 Atmospheric Condition 1 13 Auto Detect Display eem 10 Auto Scale Graph 1 20 Aux Channel Name 24 C eer 13 Change the Graph Box 512 5 22 Changing the Graph Axis 18 Common Left amp Right Graph 19 Conventions SCO m 1 Cursor Read out Display eeeeeee 22 D BN BOK T 16 Data Properties 23 D
37. played graph data to be mathematically averaged Smoothing 1 between the highs and lows to produce a smoother data output Jata Type File Locations The Slider Bar can be moved from 0 No smoothing to 10 for maximum smoothing File Properties Engreering Lins Special Funcnons Help Fie Properties Engmeering ints Special Funcions wie GEF cak EB PRL Comont BERITE OHP Conector gal EF caw EaR tlg PERIE T oun Conocen Fis Name Title Dae Data File Localon MaxFows Power Max Tague Tore No Fie Name Title Dae B 06e 157 0 20 153211 13130 2 ipm 16 55 Ft 1 Time Data Type File Localon MaxFowes c Max Taique Tore No 115 06 bhp 1098 mpm 1 ELIDLTM TT 16 4 0 20 152211 1li453bhp 13372m 4645FU b 11650809 me 1 qa p Repeatabsity Dpr Air Temperature 25 C Air Pressure 1008 Humidity 5 8 CF 0 096 RAD 94 86 Area Power 2097 24 Area Torque 1322 1 Nolet Repeatabuty Dpr Ae Temperature 25 C Pressure 1998 20wBar Humidity 45 8 0 996 RAD 94 86 Area Power 2098 37 Area Torque 1322 24 Dyna Pro Ltd Dyna Pro Ltd 13200 400 Engine Speed rpm No Data Smoothing Slider Bar set at 0 Full Data Smoothing Slider Bar set at 10 DJHP Correction The DJHP Correction option box when ticked will display the Power and Torque data in DJHP Carrectio
38. point and a base line point 5000 Start Point rpm Finish Point rpm 10000 Base line Point p The Area Under the Graph will be calculated between these three points Area under the graph will only be calculated if Power or Torque are plotted against Engine Speed Area Under the Graph will only be calculated if Power and Torque are plotted against Engine Speed B S x 2 a Area Under Graph is calculated in this area only The results will be shown in the Notes Box 7000 8000 9000 10000 Engine Speed rpm Cancel Save amp Exit FA Dyna Pro Run Viewer If Show Area Line Annotations has a tick to the left File Properties Engineering Units Special Functions Help a ex we EEr Eje EEE meli emm o ceinte Eee wecem _ Ofit then Dyna View will show the calculation limits on File Name Dat Time Data Type File Location Max Power Power amp Max Torque Torque 14 R6 Repeatability 15 1 oe 15 37 11 MSF M C Program Files Dy 114 74 bhp 13439 7 46 47 11057 1rpm 1 t h e g rap h Notes 44 Re Repeatability Dpr Air Temperature 25 C Air Pressure 1008 2mBar Humidity 45 8 C F 0 996 RAD 94 86 Area Power 2099 09 9nre Iorque 1322 63 wntwdynapro co uk Dyna Pro Ltd Area Under Graph Data 2 a T o a Area Under Graph is calculated in this area only 9134 enbioL Air Cheisction SAE J134 DJHP Correct d Power 6000 7000
39. ressure 1011 7mBar Humidity 42 2 0 972 RAD 97 85 N ot th at th e f L e ft a n d R g h t A X S o r e n OW b ot h Warm up Lu Dyna Pro Ltd scaled from 40 to 130 m bb dl Il RE Mq This Icon Appears to be raised Power bhp 153 enbsoL Air Correction SAE J1349 DUHP Corrected Power 9000 Engine Speed rpm Graph Box Separation Turn On Off Multi graph Separations by left mouse clicking z 2 E PEE Axis Separation 0 e Air Correctipn SAE J1349 0 C T aed 100 m 80 60 1 0 1 1 1 eee S me 40 20 0 0 11000 12000 13000 14000 15000 11000 12000 13000 14000 15000 With Axis Separation No Axis Separation 21 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Change the Graph Box Sizes If you have more than one Graph Box displayed it is also possible to change their size ratio If you move the Mouse Cursor over the Bottom Axis of one of the upper Graph Boxes you will notice that the Cursor Arrow will change from a Single Arrow Pointer to a Double Arrow Pointer When this occurs you can Click and Hold the Left Mouse button down whilst dragging the bottom of the Graph Box to its new position All Graph Boxes have a minimum size set a
40. roy all copies of the Licensed Works any accompanying documentation and all other associated materials GOVERNING LAW This License Agreement shall be governed by the laws of the United Kingdom WARRANTIES AND DISCLAIMER EXCEPT AS EXPRESSLY PROVIDED OTHERWISE IN A WRITTEN AGREEMENT BETWEEN LICENSOR AND YOU THE LICENSED WORKS ARE NOW PROVIDED OAS ISO WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR THE WARRANTY OF NON INFRINGEMENT WITHOUT LIMITING THE FOREGOING LICENSOR MAKES NO WARRANTY THAT i THE LICENSED WORKS WILL MEET YOUR REQUIREMENTS ii THE USE OF THE LICENSED WORKS WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE iii THE RESULTS THAT MAY BE OBTAINED FROM THE USE OF THE LICENSED WORKS WILL BE ACCURATE OR RELIABLE iv THE QUALITY OF THE LICENSED WORKS WILL MEET YOUR EXPECTATIONS v ANY ERRORS IN THE LICENSED WORKS WILL BE CORRECTED AND OR vi YOU MAY USE PRACTICE EXECUTE OR ACCESS THE LICENSED WORKS WITHOUT VIOLATING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS SEVERABILITY In the event any provision of this License Agreement is found to be invalid illegal or unenforceable the validity legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired and a valid legal and enforceable provision of similar intent and economic impact shall be substituted theref
41. s Air Correction Factor 0 02 atmospheric differences will be shown regardless of what limit parameters were set 4 Always show the above Atmospheric differences when opening Dyno Runs Cancel Save amp Exit When you have finished click on the Save amp Exit button Calculator Dyna Pro Run Viewer File Properties Engineering Units Special Functions Help 1 p Fi Bc Calculator Ja File Edit View Help CAF Hes Dec Bin Degrees Radians Grads OH idity 4 This function will display the Microsoft system calculator E JEJE bee Li JL J Ln J D D JES LS JL Joe JL EJ C a 13 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Drop Down Menus Help eE Left mouse click on Help to show the Help drop down menu Dyna View Manual Fi elites see Key Stoke Function Keys Produce Brochure Smoothing About Dyna View Manual Left mouse click on Dyna View Manual to show this manual Units Special Functions Ele Dyna View Manual mil Smoothing Title Key Stoke Function Keys P ieee a NOTE That Adobe Reader must be installed on the user s computer ar to be able to view this file Key Strokes Function Keys Left mouse click on Key Stro
42. s default if you try to make a Graph Box to small it will automatically resize itself to its smallest default size AP Las PaaS OAT SON aaa END Re SED aL Ted a CU UNDC SEES 1 5 URP er mM Drag this section ane JA ET Sa teeter eee E nemen moe em i p ME Baas Penis ve team OE J Ai Gavicahion SRE GES TDIP Cosreciad Bhan of the Graph Box Resized Bottom Notes pem Ak Temperature 20 C Presoure 198 Hom 4 8 CFL RAR SLIS Graph Box www dynapro co uk Dyna Pro Ltd eec m M o 2 222222 2 2 2 2 2 2 2 2 2 2 2 2 24 2 2 2 a4 41 Coirediies SAE JENS DJHP Corrected Power e S peeds euiBu Ein dn cu uo a iu cn o5 Selb Ra dn am los Ba du di lan a jn an eo d de au aj in o au ad n du ons t in aad Ra du do ad ad Cursor Read out Display 123 This Icon if selected will turn on the Cursor Data Read out If you left mouse click over a Dyno Run graph it will display data at the point at which the mouse button was pressed In addition to the mouse click you can also use the Keyboard Arrow Keys to move the cursor data along the graph The Left and Right Arrow Keys move the cursor data along by one step at a time whereas the Up and Down Arrow Keys will
43. tate Basingstoke Hampshire United Kingdom RG22 4DQ or visit us on the world wide web at www dynapro co uk for the latest product release and updates Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Dyna View Display Summary zz Data Controls Drop Down Menus 3 Dyna Pro Run Viewer aag Control Icons T properties Engineering Units Special Functions Help x amp amp ET 2 3 BE Smoothing orection Factor SAE J1349 g DJHP Correction 2 File Name EX Tile Dae Time DataType File Location Max Power Power Torque Torque No Data List Bo 14 RB Repeatability 15 10 20 15 37 11 MSF M 114 74 bhp 13439 7 rpm 46 47 Ft lb 11057 1 pm 1 Notes Box Notes 14 R6 Repeatability Dpr Air Temperature 25 C Air Pressure 1008 2mBar Humidity 45 8 CF 0 996 RAD 94 86 Area Power 2099 69 Area Torque 1322 63 Graph Identifier www dynapro co uk Dyna Pro Ltd 120 i 100 SES SSeS Se SO SA SS SOS Sg SSS eee e Se ESSERI ACER DERE TI SO SOS TIS ICE LATTE TC ATTE EO SES ee Et IC SS SOD DOSS E Eee rn RR Left Hand Axis Label Graph box 1 MEIN Swnobwno beste iy relate ldbw dye s UEM ses A A coo N NAAN O
44. up C Program Files Dyna Pro Dynamometers Logged Data Example Data 7 RG500 New CDI Dpr Yo U Ca n L ef S e C l I ck O n a n y of th es e fi es a n d It WI e Print Options C Program Files Dyna Pro Dynamometers Logged Data Example Data 6 RGY500 Multi Gear Dpr L J Print Preview C Program FilesiDyna Pro Dynamometers Logged Data Example Data 5 RGY500 Multi Gear Dpr O pe n ed fo V ewl n 9 Dyn a Vi e W Print Ctrl P C Program Files Dyna Pro Dynamometers Logged Data Example Datal4 RGV500 Single Gear Dpr C Program FilesiDyna Pro Dynamometers Logged Data Example Datal3 RGV500 Single Gear Dpr C Program FilesiDyna Pro Dynamometers Logged Data Example Data 2 RGV500 Single Gear Dpr Exit F12 C Program FilesiDyna Pro Dynamometers Logged Data Example Datali RGV500 Single Gear Dpr Run Data Properties 28 Dyna Pro Run Viewer EE Properties Engineering Units Special Functions Help Open Graph F2 Recent Files gt Right mouse click on Run Data Properties to show the blue Highlighted Dyno Run properties window Please see later for use of Data Properties Dialog in the Data List Run Data Properties Remove this Dyno run Remove All Runs F3 B O XxX ch apt er Print Set up Print Options Print Preview This Icon has the same effect as Run Data Properties Print Ctrl P Remove This Dyno Run 28 Dyna Pro Run Viewer WM Properties Engineering Units Special Functi
45. y laws and all of the terms and conditions of this Agreement and further agree to take all necessary steps to ensure that the terms and conditions of this Agreement are not violated by any person or entity under your control or in your service OWNERSHIP OF SOFTWARE The Licensor and or its affiliates or subsidiaries own certain rights that may exist from time to time in this or any other jurisdiction whether foreign or domestic under patent law copyright law publicity rights law moral rights law trade secret law trademark law unfair competition law or other similar protections regardless of whether or not such rights or protections are registered or perfected the Intellectual Property Rights in the computer software and hardware together with any related documentation including design systems and user and other materials for use in connection with such computer software in this package collectively the Licensed Works ALL INTELLECTUAL PROPERTY RIGHTS IN AND TO THE LICENSED WORKS ARE AND SHALL REMAIN IN LICENSOR PRODUCT ACTIVATION Your use of the Software is governed by product activation technology that limits the number of installations and total number of computers on which the Software This product activation technology may not be circumvented or otherwise disabled in any way RESTRICTIONS a You are expressly prohibited from copying modifying merging selling leasing redistributing assigning or transferring in an
46. y matter Licensed Works or any portion thereof b You may take a single copy of materials within the package or otherwise related to Licensed Works only as required for backup purposes c You are also expressly prohibited from reverse engineering decompiling translating disassembling deciphering decrypting or otherwise attempting to discover the source code of the Licensed Works as the Licensed Works contain proprietary material of Licensor You may not otherwise modify alter adapt port or merge the Licensed Works d You may not remove alter deface overprint or otherwise obscure Licensor patent trademark service mark or copyright notices e You agree that the Licensed Works will not be shipped transferred or exported into any other country or used in any manner prohibited by any government agency or any export laws restrictions or regulations f You may not publish or distribute in any form of electronic or printed communication the materials within or otherwise related to Licensed Works including but not limited to the object code documentation help files examples and benchmarks TERM This Agreement is effective until terminated You may terminate this Agreement at any time by uninstalling the Licensed Works and destroying all copies of the Licensed Works Upon any termination you agree to uninstall the 26 Dyna Pro Dynamometers Ltd Dyna View V2 User Manual www dynapro co uk Licensed Works and return or dest

Download Pdf Manuals

image

Related Search

Related Contents

第3章 試験設備および試験手法  ministerio de trabajo ministerio de agricultura  Manuale  Swingline V110E paper perforator  User manual M2  Service Manual Alex  USER`S MANUAL  取扱説明書 [F-02A]  取扱説明書はこちらをクリックしてください。  Planon System Solutions PrintStik DPEN-PS900 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file