Home

Instruction Cum User Manual For EUROVAC

image

Contents

1. float valve sticking kinked tubing and rectify If the vacuum gauge still indicates a vacuum Pump does not suck however the cause is internal Vacuum gauge indicates a vacuum www anandind com Page 5 DOC ID NO 6101 F REV 01 www suction india com DATE 09 10 2010 Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high quality and workmanship of each Anand s HI VAC for a period of one year subsequent to the date of delivery by the company During this period faulty material will be replaced free of charge This warranty does not extend to components that are subject to wear and tear in the course of normal operation or due to improper treatment maintenance as per instructions Further conditions in accordance with international standard IEC 601 1 item 6 8 2b The manufacturer is only responsible for effects on the safety the reliability and the performance of the appliance if e Installation additions adjustments modifications or repairs are carried out by personnel authorized by the manufacturer e The electrical installations within the room concerned satisfy the requirements laid down by IEC e The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training The safe and effective use of this product largely depends on the skill of the operator
2. An ISO 9001 2008 13485 2012 Certified Company Anand NEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC CE 2195 Vacuum control knob Vacuum Gauge w Connector for Patient use Push in Nozzle k A __y Float for Nylon Lid ACU gt 9 Ler PC Jar MainLead Connector On Off switch lt n L O ABS Enclosure Bacterial Filter Safety Jar Back Side Dear Customer Congratulations on your purchase of this versatile and need oriented suction unit It will serve you well for years if properly looked after The medical professions have long felt the need for a lightweight easy to move safe dependable and easy to regulate suction unit EUROVAC fills this healthcare need to a degree unmatched by any other unit It is designed for use in hospitals nursing homes doctor s offices pediatric care ICU s and home care Non corrosive and shockproof enclosure is pressure moulded in engineering plastic ABS giving smooth and easy to clean surface ASSEMBLY The pump is housed in the enclosure To fasten it well with the base two black head screws used as holdfast for transportation at the bottom of the unit MUST be removed by rotating with the aid of a simple hand tool The bacterial filter is slipped into the safety jar at the back and the other end is connected to the nozzle marked Vacuum on the jar lid The second nozzle is marked patient and the tubing from this goes to the pat
3. ORIZED PUMP WwWwW anandind com Page 4 DOC ID NO 6101 REV 01 DATE 09 10 2010 www suction india com i Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC TROUBLE SHOOTING Possible source of trouble Check Action to be taken Power Supply Voltage power socket Main switch Set at ON Electrical cord Plug type plug connections damaged cord Check if the safety jar is activated Open the safety jar clean amp dry the jar and replace the cap for re use Not Run Ta 09 O O O O E The blood has entered the pump The remedy is given above under pump cleaning Leak within the pump or in the external Isolate the source of trouble by carrying out suction circuit the checks outlined External cause Push in connector O rings Lid gasket Condition Push in angular connectors No Leaks at tube ends Push in as far as stop Bacteria filter housing on Safety jar top Filter paper Condition position of housing Blockage or kink in tubing within the Isolate source of trouble as follows Inadequate Suction Performance pump or in the external suction circuit Remove the safety jar leave the suction connection open If the vacuum gauge now indicates zero vacuum the cause is external External cause Bacteria filter safety jar overflow valve in the Investigate the whole external suction circuit lid float valve push in connectors tubing etc for blockage s
4. S FOR USE Safety Jar Safety jar with electronic overflow monitoring sensor and bacterial filter is at the back Negative Pressure Before the unit is put to use required vacuum must be set by occluding the safety jar nozzle and controlling the release valve Fully tightened clockwise vacuum control knob means full vacuum Jars Tubings The material of the jars polycarbonate PC is superior to glass It is less fragile when subjected to impact and less sensitive to temperature shock PC is resistant up to 120 c provided it is not subjected y to any physical loading As the flow rate is high 3 4th filling of the jar is recommended The lid has a ae built in antifrothing device The jar is easier to clean if a little water or disinfectant is put into it prior to suction operation The safety jar must however remain dry Tubing after use can be brittle and must be changed 2 Ltr PC Jar Cleaning and Disinfecting After each use jars lids overflow cut off valve catheters etc should be cleaned thoroughly When cleaning is necessary after infective fluid has been evacuated the jars lids cut off valve and tubing can be sterilized by autoclaving upto 120 C for 20 minutes Alkaline cleaning agents and disinfectants based on phenyel may not be used Adherence to hospital directives on hygiene is of prime importance The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization and or disi
5. We are not liable for any damages due to mishandling or improper and unauthorised use e The company reserve the right to change technical specifications designations and catalogue numbers without prior notice Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 240V 50 Hz Ensure that the suction unit should not be lifted above human body level Dispose of used product packaging in safe manner so as not to harm stray cattle children and environment WARRANTY CARD Model No ____LL eee Lee LLL LLL INN eee eee Date of Purchase Dealer Name taal ANAND MEDICAIDS PRIVATE LIMITED Regd Office 33 16 Punjabi Bagh Extn New Delhi 110026 India Tel 91 11 25225225 25229206 42464264 Fax 91 11 25225062 E mail sales anandind com Works 1460 M I E Bahadurgarh Haryana 124507 India EC REP KALEIDOS SH VIA PONTIOA 4 2012 MILANO ITALY WwWww anandind e com Page 6 DOC ID NO 6101 REV 01 DATE 09 10 2010 www suction india com
6. ghtly placed on the jars To avoid leakage the push in and angular connectors must be inserted as far as the stop While unplugging twist and pull 5 The main power supply is well earthed In case of fluctuation use voltage stabilizer corrector 6 The vacuum control knob is not loose It must be fully tightened clockwise TECHNICAL Housing Engineering plastic moulded shock resistant ABS with 2 size hooks to hold tube Capacity 575mm Hg 10 at 25 Itrs min Pump type Single Oil free diaphragm pump mechanism provides reduced maintenance cost Jar Wide mouthed autoclavable 2 Itr collection jar Polycarbonate Tubing 8 mm ID x 2 mtr Silicon Vacuum Gauge 6 25 cms 2 5 inch 0 760mm Hg calibration Power 220V AC 50 Hz 125 watts 110V on request Dimension amp Weight 20 x 42 x 36 cms 7 5 kg Wwww anandind ecom Page 2 DOC ID NO 6101 REV 01 DATE 09 10 2010 www suction india com i Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC VACUUM AT ALTITUDES The specified maximum vacuum refers to sea level According to local conditions and barometric pressure slight deviations in vacuum reading may be noted The table below shows several factors by which the indicated maximum vacuum value must be multiplied according to the altitude of location where the measurement is carried out Location Maximum Vacuum Location Sea level 1000m 2000m 4000m Factor 1 00 0 88 0 78 0 60 GUIDELINE
7. ient The release valve for adjusting the negative pressure and the vacuum gauge are on the panel An on off switch cum pilot lamp fuse and the removable main lead connector are on the side www anandind com Page 1 DOC ID NO 6101 REV 01 DATE 09 10 2010 www suction india com l Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC The EUROVAC is a versatile suction unit with minimal installation efforts This section contains information on installing the unit 1 Connect the short silicone tube marked as A to the two litre Lra e A plastic jar lid marked as B in the figure above mi h f oim e 2 Safety jar with filter on the top are fitted at the back Fig on l Lai Ti T page 1 Connect the other end of the tube A to the filter at the ena back of the unit ee Fe La 3 Connect the long silicone tube to the nozzle marked Patient on the two litre plastic jar lid 4 Attach the power cord to the socket on the side and connect the plug to the electrical mains supply 5 Switch the unit on and it is ready for use Before you turn on the unit please ensure that 1 O ring on push in connector and safety jar are not worn out 2 Jars are checked for possible crack or flawed spots Any defect can result in implosion under vacuum 3 Check the bacterial filter and change the filter element if necessary The housing must be flip tightened 4 The lids and tube are ti
8. nfection units must also be Bacterial Filter followed where application temperature process duration and airing etc are concerned www anandind com Page 3 DOC ID NO 6101 REV 01 DATE 09 10 2010 Www suction indtia com l Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC PUMP The unit fitted with Diaphragm type oil free pump provides reduced maintenance cost A Open the back plate of the unit with the aid of an allen key provided and disconnect the tube from the inlet and outlet points on the pump housing Fig A B Unscrew the 2 hexa bolts from the bottom of the unit and take out the motorized pump fitted on and together with the platform C The fly valves are fitted Fig C in the top which can be opened The valve and sieve are alternately fitted one upon the other in the two nozals making one for vacuum and the other for outlet The diaphragm is fitted below the top plate Fig B and over the eccentrically rotated came Just wipe clean these parts and set the unit again D Please run the unit and see its satisfactory functioning before the back plate is screwed up Unlike the rotary design NO LUBRICATION IS REQUIRED IN THIS PUMP The unit has not to be tampered with by any mechanic other than our factory engineer or the person authorized Fig B Filter Gauge Sensor Safety Jar Release i Valve 9 0 Jee Outlet 220 V AC PC CARD Inlet MOTOR MOT

Download Pdf Manuals

image

Related Search

Related Contents

Foxit PhantomPDF_User Manual    -32 ….1200°C  Lab Source Manual - Newport Corporation  ZXR400 Motorcycle Service Manual Supplement  Kensington Triple Trek™ Ultrabook™ Optimised Carry Bag  premières pages - R    SBC35-CC405 User Manual  Instrucciones de usuario  

Copyright © All rights reserved.
Failed to retrieve file