1. Connect G3 to the 2 ml mixer chamber outlet and to V1 Injection Valve INV 907 Mount the sample loop 500 ul 18 1113 99 on V1 Connect W1 and W2 to V1 and put the open ends of W1 and W2 in a waste bottle Instruction 56 3136 00 Edition AC 9 Connect G4 to V1 and to the inlet of the UV flow cell top connection 10 Connect the union 18 1120 93 between the outlet of the UV flow cell bottom connection and the flow restrictor FR 904 marked IN The flow restrictor should be housed in the hole in the pH flow cell holder 11 Connect the other end of the flow restrictor to W3 Put the open end of W3 ina waste bottle Checking the installation When all of the installation is carried out check that all the connections and mountings are performed according to the diagram 56 3063 99 AKTAbasic 100 installation test Perform an installation test as described in the AKTAbasic User Manual When the test is finished disconnect G4 from the UV flow cell and connect the union 18 1120 93 to the cell instead AKTAbasic 100 test record Make a photocopy of the test record included in the AKTAbasic User Manual and store the test record in the AKTAdesign System Logbook Store also the packing lists in the System Logbook Accessories The accessories included in the upgrade kit is to complement the upgraded system to original delivery status Store the accessories in Box 900 or wherever convenient for the customer Sas Th
2. GE Healthcare Bio Sciences AB Required tools and documents Tools included in Tool kit 56 3008 20 included in existing system Fiber detachment tool 18 1111 16 included in existing system Connection diagram capillaries 56 3063 99 included in upgrade kit AKTAbasic User Manual Box 18 1140 99 included in existing system or in the UNICORN CD AKTAbasic 10 to AKTAbasic 100 Upgrade kit Instruction 56 3136 00 Edition AC Removing AKTAbasic 10 capillaries WARNING When using hazardous chemicals make sure that the entire system has been flushed thoroughly with bacteriostatic solution e g NaOH and distilled water before removing any capillaries WARNING Ensure that the mains supply is disconnected before starting the installation Remove all capillaries and connectors from the separation unit and the Pump P 903 The following items will be reused W1 W3 56 3047 57 Piston seal rinsing system 18 1113 32 Flow restrictor FR 904 18 1112 42 Inlet filters 18 1113 15 Removing KTAbasic 10 components Remove the 10 mm UV flow cell Use the fiber detachment tool 18 1111 16 Remove the four 10 ml pump heads including pistons and return springs Use the 3 mm Allen key included in Tool kit 56 3008 20 and save the attachment screws They will be re used AKTAbasic 10 to AKTAbasic 100 Upgrade kit 3 Instruction 56 3136 00 Edition AC Installing AKTAbasic 100 components 1 Assemble the 100 ml pump heads according to
3. Bio Sciences Corp 800 Centennial Avenue P O Box 1327 Piscataway NJ 08855 1327 USA GE Healthcare Bio Sciences KK Sanken Bldg 3 25 1 Hyakunincho Shinjuku ku Tokyo 169 0073 Japan imagination at work Instruction 56 3136 00 AC
4. GE Healthcare AKTAbasic 10 to AKTAbasic 100 Upgrade kit Instruction Conversion kit code number 18 1148 55 IMPORTANT Read through this instruction in whole before commencing with the installation Contents CONTENTS hurgnmnuneouni anaa a aaa anen a aaa aa ER 1 GENERAU onaanuni unuo aaa aA R N aE 1 UNPACKING panttina ann nene eanan a a a a a a a a a a an 2 SOFTWARE PRE REQUISITES inunasumiunnoniannsanoininen eiaa ona a aada a ana aia aiana 2 REQUIRED TOOLS ANO DOCUMENTS ovanti Aan AAAA AAAA RANA AEA 2 REMOVING AKTABASIC 10 CAPILLARIES ssscsssosssssscsssssssssssscssecssesscssssssessesssnsesssssssssssseessssessesseseustissuesaseessssssssssssseseseceseceecseeeeseeseceescessseeniesseese 3 REMOVING AKTABASIC 10 COMPONENTS veesecesesssesssssssssssvsssssscssescesscsssessesevesessssssssssssssssesseseceseceesscceuettuesesesssesssesssssrseseeeeseesecseesessceeeseessceninseese 3 INSTALLING AKTABASIC 100 COMPONENTS veesecesescsssssssssvssssscsssesscssessssssesscsesssesssssssssssssssesecaseceessecesettuesesensessssssssstssessesecesesececaseceeseeessesseeseese 4 INSTALLING AKTABASIC 100 CAPILLARIES ccesccscsssssssssssssscssccssesscssesssessesesssessssssssssssssesssceseceecesssuesuiusasesnsesssssssssssssscesseseesscesasesseceseseessesseeseese 4 CHECKING THEIN STALLA MON area Rasa eset sec doce peat cee E S N tess dese tees Rte tale E es sessed 5 AKTABASIC 100 INSTALLATION TEST csecessssssssssssssssssssscsscsscssssssesssecusesssssssssssssssssssssecaseecesses
5. iesuuaseessessssssssessesessseeeseseecsececaeeceeesesiesiuetieseeseesneesess 5 AKTABASIC 1100 TEST RECORD ssssssasesessscecssnsscoscsctcascesasozscassujeselvacaseustustsencanonssceducbccedbaovssaviusaasectaveusedusbocedbonivsesbcoteonsanacecsbbecedsvustdutiddeessansaded 5 ACCESSORIES asec scc avec eta eect A tact tech cca E A T E EAE 5 General The AKTAbasic 10 to AKTAbasic 100 upgrade kit converts the flow rate from 10 ml to 100 ml and maximum pressure range from 25 MPa to 10 MPa P903 is converted to P 901 The kit also includes capillaries and other components in the flowpath Unpacking Unpack the AKTAbasic 10 to AKTAbasic 100 conversion kit and check the items against the supplied packing list Inspect the items for obvious damage which may have occurred during transportation Please note that some of the included packages have their own packing lists included Check these as you go along It is recommended to reuse the packing material to pack the surplus AKTAbasic 10 equipment for possible future use Software pre requisites Before you start disassembling the AKTAbasic 10 system install UNICORN version 3 21 or later Then install the AKTAbasic 100 strategy from the same CD General installation instructions for UNICORN software are given in the UNICORN User Manual IMPORTANT Make sure that the existing AKTAbasic 10 system is equipped with purge valves on the pump heads If not contact the Technical Support Department of
6. instructions in the Pump P 900 User Manual Changing piston sealings Mount the 100 ml pump heads Please observe the UP marking Fit in position and fasten using the old attachment screws Mount the piston seal rinsing system capillaries Please observe the flow direction of the check valve arrow should point towards the front of P 900 Mount the pump head capillaries The capillaries from the A pump heads should be connected to the inner part of the outlet manifold Mount the inlet manifolds on each pump module and fix with the screwed end pieces do not overtighten Mount the 2 mm UV flow cell 18 1111 10 Use the fiber detachment tool 18 1111 16 Slide the rubber sleeves on the two optical fibers onto the connectors Make sure that the sleeves are pushed tight to the housing to prevent dust or fluid from entering the connections Note Fit all the protective caps on the old 10 mm flow cell Installing AKTAbasic 100 capillaries 1 KTAbasic 10 to KTAbasic 100 Upgrade kit If not already done unpack and check the KTAbasic 100 tubing kit cpl 18 1121 58 Change the inlet filter inserts 18 1114 42 if required Attach the inlet filters to capillaries A1 and B1 Connect the inlet capillaries A1 and B1 in that order according to diagram 56 3063 99 Connect G1 and G2 to the 2 ml mixer chamber inlets G1 is connected to the inner part of the outlet manifold A pump heads and G2 to the outer part B pump heads
7. is symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment AKTAbasic 10 to AKTAbasic 100 Upgrade kit 5 Instruction 56 3136 00 Edition AC www gehealthca re com AKTAbasic AKTAdesign and UNICORN are trademarks of GE Healthcare Ltd a General Electric company GE imagination at work and GE monogram are trademarks of General Electric Company GE Healthcare Bio Sciences AB All goods and services are sold subject to the terms and conditions of Bjorkgata n 30 sale of the company within GE Healthcare which supplies them GE Healthcare reserves the right subject to any regulatory and 75184 U ppsala contractual approval if required to make changes in specifications Sweden and features shown herein or discontinue the product described at any time without notice or obligation Contact your local GE Healthcare representative for the most current information 2005 General Electric Company All rights reserved GE Healthcare Bio Sciences AB a General Electric company GE Healthcare Bio Sciences AB Bjorkgatan 30 SE 751 84 Uppsala Sweden GE Healthcare Europe GmbH Munzinger Strasse 5 D 79111 Freiburg Germany GE Healthcare UK Ltd Amersham Place Little Chalfont Buckinghamshire HP7 9NA UK GE Healthcare