Home

2 - scalenet.com

image

Contents

1. 0 0 LB or 0 0 KG appears on the display 4 Ask the patient to step on the scale The scale will begin to display weight information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale to lock onto the weight 5 Once a weight has been displayed while the patient is still on the scale Health o meter recommends performing a second weighing by pressing the REWEIGH button 6 The weight may be held on the display by pressing the HOLD RELEASE button To release press the HOLD RELEASE button again 7 After the weight measurement has been taken and is recorded have the patient step off the scale 8 Press the ON OFF button to power the scale off Weight Recall The last weight reading on the scale can be recalled by pressing the RECALL button To clear the display of the recalled weight press the ENTER button Note Clearing the recalled weight from the display will not clear the recalled weight from memory The recalled weight will remain in memory until another weight is obtained 16 QUICK START OPERATING INSTRUCTIONS CONT BMI Function Body Mass Index is another name for Quetelet Index a formula that is a convenient indicator of BMI with various exemptions such as athletes children the elderly and the infirm Note The scale will not calculate BMI for a patient that is 24
2. shield above the wheel Plug the connector into the load cell port located on the side of the platform see Figure 7 Pull the excess cable through the top of the center handrail see Figure 2 9 Thread the 4 feet into the underside of the platform Each foot should be completely hand tightened Once tighten back feet out 1 full turns This allows for proper load cell operation for accuracy of the scale see Figures 2 amp 7 10 Carefully tilt the scale back to an upright position on the floor Warning Do not drop scale as this can permanently damage the load cells 11 Adjust the feet to level the scale Be certain that the feet are not completely tightened into the platform refer to the scale platform feet assembly instruction above 12 Position the display assembly close to the display support Plug the load cell cable connector into the load cell port on the rear of the display assembly see Figures 2 amp 6 Note Do not attach the power cord at this point 13 Align the four mounting holes on the back of the display assembly with the four mounting holes in the display support Fasten the display assembly onto the metal display support by using 4 Phillips pan head M4 screws D Use Phillips head screwdriver to tighten the screws see Figures 1 amp 5 1100KL ASSEMBLY INSTRUCTIONS CONTINUED 14 Place the pivot bracket screw covers over the pivot screws Fasten the covers to the back of the display using
3. 4 Phillips pan head M4 screws D Use Phillips head screwdriver to tighten the screws see Figures 1 amp 5 15 Attach the adapter holder to the center rail using 2 8 x Y sheet metal screws C Use Phillips head screwdriver to tighten the screws see Figures 1 amp 2 16 Connect the AC adapter to the power port in the display Do not plug the scale into a power source until the scale is fully assembled see Figure 6 17 Attach the front and rear display support covers applying light pressure to snap these covers into place see Figure 2 18 The scale is now assembled Plug the AC adapter into a power source and or insert batteries 1100KL ASSEMBLY INSTRUCTIONS CONTINUED 8 Figure 1 DISPLAY ASSEMBLY RIGHT PIVOT BRACKET MURENE GOVER LEFT PIVOT BRACKET SCREW COVER BACK DISPLAY SUPPORT COVER FRONT DISPLAY SUPPORT COVER RIGHT HANDRAIL AC ADAPTER BRACKET AC ADAPTER CENTER HANDRAIL SCALE PLATFORM FEEL 1100KL ASSEMBLY INSTRUCTIONS CONTINUED A Faremos es da a Health o meter CO a s q v A FA Es A TE yl O q a o ie eh arm x 4 e is Dm a 4 E as ar gt 227 UN pe y A f OO E Load cell cabl i 1100KL ASSEMBLY INSTRUCTIONS CONTINUED Figure 6 Protective metal shield Cable connector Figure 7 11 SETUPIBATTERIES 0707575353500 Preparing the 1100KL Scale for Use 1 Remove the protective plastic film covering the display the
4. Health o meter Pr o re 3 ee 60 na i Model 1100KL Digital Handrail Scale User Instructions P N UM1100KL Rev 3 080613 Health o meter Model 1100KL Thank you for your purchase of this Health o meter Professional product Please read this manual carefully and keep it for easy reference or training TABLE OF CONTENTS _ _ _ _ _ _ caution ana VVAMNMG sicczcccxcxeecsexesenaveterssanctercnocetercaerateressnederesseanenssetasessneuatessseuadeeencs e 3 Speciicatlons TOF ENS Cal surrena n a a ee aE aa 4 Certifications Connectivity Disposal errar 5 Assembly Instructions 1100KL Scale 2 022202200200000002n0 nenn Bene anne nnne anne nnnnnnnn 6 SON A BANCOS rrer Re o OE A 12 Quick Start IMS WICH ONS nenne 14 Wues lla llar q e APRA PO uo ne o PU Ia 18 05 110 a RR DR O en ne ere 19 ITOUDIESNOOING PURE STR ER 20 DN PAD oss oc o ana dan 21 Note This scale has been factory calibrated and does not require calibration prior to use Please register your scale for warranty coverage at http www homscales com customer registration aspx For User Instructions updates and revisions please go to http www homscales com CAUTION AND WARNING e To prevent injury and damage to your scale please follow these instructions very carefully e Assemble and operate the scale per the enclosed user instructions e Operate this scale exclusively with the AC adapter pro
5. To prevent patient injury the patient must be attended throughout the entire weighing event e Ifthe scale is being connected to another medical device the power adapter must not be used Disconnect the power adapter from the scale and use only the battery power SPECIFICATIONS FOR THIS SCALE General The Model 1100KL digital handrail scale uses highly sophisticated microprocessor technology Each precision scale is designed to provide accurate reliable and repeatable weight measurements In addition each scale is designed to provide the user with features that make the weighing process simple fast and convenient This scale is set up to use motion sensing weighing technology in order to determine the actual weight of a moving patient Weight can be displayed in pounds or in kilograms The scale features built in handrails for patient comfort and safety It also has a 180 swivel display head for privacy and easy operator reading from either side of the scale This scale has 2 wheels built in for easy mobility This scale can be powered using an AC adapter included or by 6 AA batteries not included 1100KL Scale Specifications Capacity and Resolution 1000 Ib x 0 2 Ib 454 kg x 0 1 kg Power Requirements 110 240VAC 50 60Hz 9V DC adapter or 6 AA batteries Environmental Operating temperatures 50 F to 95 F 10 C to 35 C Storage temperatures 30 F to 125 F 0 C to 50 C Maximum Humidity 85 RH Physical D
6. ers such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 377 0600 to receive a return authorization RA number which must be included on the return label Attach your proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Return Department 9500 West 55 Street McCook IL 60525 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing PELSTAR LLC 9500 West 55 Street McCook IL 60525 USA 1 800 638 3722 or 1 708 377 0600 PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT http www homscales com customers registration aspx Health o meter is a registered trademark of Sunbeam Products Inc used under license Health o meter Professional products are manufactured designed and owned by Pelstar LLC We reserve the right to improve enhance or modify Health o meter Professional product features or specification
7. film says FACTORY CALIBRATED 2 Place batteries into the battery holder see Replacing Inserting Batteries information below 3 Connect the AC adapter into the adapter jack on the display assembly Warning To avoid a safety hazard use AC adapter model ADPT30 4 Plug the scale s AC adapter into the power source 5 Ensure all objects are removed from the scale s platform and then press the ON OFF button to power the scale on The display will show Start then 0 0 LB or 0 0 KG Press the UNIT button to select the weight mode LB or KG Note This scale will always default to the settings and units last used LB or KG 6 When the AC adapter is disconnected from the scale the scale will switch to battery power if batteries are installed Note If the set up procedure failed refer to the troubleshooting instructions If the problem is not corrected refer to qualified service personnel Replacing Inserting Batteries 1 Unplug the AC adapter from the power source 2 Remove the battery cover on the side of the display assembly by unscrewing the 2 battery cover screws see Figure 7 3 Replace or install the batteries with new units Health o meter recommends using an alkaline or lithium battery rated for 130 F 54 C operation Do not use Zinc Carbon batteries 4 Re attach the battery cover to the display assembly Warning If the scale will not be used for some time remove the ba
8. imensions Platform Assembled Size and Weight Length 18 46 cm Length 29 1 4 74 cm Width 22 56 cm Width 31 78 7 cm Height 2 1 2 6 cm Height 49 1 2 126 cm Weight 53 Ib 24 kg Certification Descriptions of Health o meter Professional medical devices The Pelstar CERTIFIED LLC quality assurance system covers the development production sales and service of medical scales and measuring systems Pelstar LLC has been officially certified as the manufacturer This product is tested to and meets the requirements of 1 UL60601 1 First Edition Safety for Medical Electrical Equipment 2 CSA C22 2 No 601 1 M90 Medical Electrical Equipment 1100KL Scale Connectivity Information To enable reliable transmission of weight height and Body Mass Index BMI data this scale is designed to connect to a computer monitor or other electronic device via a built in USB port This connectivity helps minimize a source of potential medical errors caused by incorrectly copying and then recording patient data This scale is EMR EHR compatible For more information regarding how to connect this scale to other electronic devices please contact Health o meter Professional Scales Technical Support available during normal business hours at 1 800 638 3722 1100KL Scale Disposal This Health o meter Professional scale must be disposed of properly as electronic waste Follow the national regional o
9. n using this scale the weight of an object such as a chair can be subtracted from the total weight in order to determine the weight of the patient alone The Tare Function automatically performs this subtraction The 1100KL scales allow tare weight to be entered manually by using the keypad or automatically as outlined in this section Tare 1 With all weight off the scale press the ON OFF button to power on the scale 2 Wait until the 0 0 LB or 0 0 KG appears on the display 3 Place the object to be tarred on the scale The display will show a value for the object s weight 4 Press the TARE button The scale will zero out and the word TARE will appear at the bottom center of the display indicating that there is a tare value for the object 5 Remove the object from the scale Once the object is removed from the scale the display will show a negative weight equal to the weight of the object 6 Place the patient and the object back on the scale The scale will automatically deduct the tare weight of the object from the gross weight of the patient and object together 7 The weight of the patient will appear on the scale 8 With no weight on the scale the tare value will remain on the display until changed cleared or until the scale is powered off 9 To remove the Tare press the TARE button The word TARE will disappear from the bottom of the display and the tare value will be cleared from the dis
10. on and troubleshooting for the 1100KL scale Maintenance operations other than those described in this manual should be performed by qualified service personnel Caution Before first use or after long periods of non use check the scale for proper operation and function If the scale does not operate correctly refer to qualified service personnel 1 Check overall appearance of the total scale for any obvious damage wear and tear 2 Inspect the AC adapter for cord cracking or fraying or for broken bent prongs Note This scale is an extremely sensitive weighing device If the auto off function is disabled battery power will be consumed Cleaning Proper care and cleaning is essential to ensure a long life of accurate and effective operation Caution Disconnect the scale from the AC adapter power source prior to cleaning the unit 1 Clean all external surfaces with a clean damp cloth or tissue Mild antimicrobial or antibacterial soap and water solution may be used Dry with a clean soft cloth 2 Do not immerse the scale into cleaning or other liquid solutions 3 Do not use Isopropyl Alcohol or other solutions to clean the display surface 4 Do not use abrasive cleaners 18 CALIBRATION Calibration This scale has been factory calibrated and does not require calibration prior to use For maintenance the scale can be calibrated Calibration of your 1100KL scale is performed using kilograms KG or pounds LB acco
11. play The scale will resume normal operation Pre Tare Limit 200 Ib 1 Make sure that there is no object on the scale 2 Press the ON OFF button to power on the scale 3 Wait until the 0 0 LB or 0 0 KG and ZERO appear on the display 4 Hold down the TARE button for 3 to 5 seconds The word TARE will appear at the bottom center of the display and the user will be prompted to enter the tare value 5 Use the keypad P and A buttons to enter the weight of the object Press the ENTER button 6 The value entered will show as a negative value on the display 7 Place the patient and the object onto the scale The scale will automatically deduct the tare weight as entered from the gross weight of the patient and the object 8 The weight of the patient will appear on the scale 15 QUICK START OPERATING INSTRUCTIONS CONT 9 With no weight on the scale the tare value will remain on the display until changed cleared or until the scale is powered off 10 To remove the Tare press the TARE button again The word TARE will disappear from the display and the tare value will be cleared from the display The scale will resume normal operation Weighing a Patient Note When this scale is powered on it will always default to the settings and units last used LB or KG 1 Make sure there is no object on the weighing platform 2 Press the ON OFF button to power the scale on 3 Wait until the
12. pounds 12 kg or less If a height is not entered for the patient within 30 seconds of pressing the BMI button the scale will return to the normal weighing mode 1 Make sure there is no object on the weighing platform 2 Press the ON OFF button to power the scale on 3 Wait until the 0 0 LB or 0 0 KG appears on the display 4 Ask the patient to step on the scale The scale will begin to display weight information and will lock on the patient s weight when the stable weight of the patient is determined Depending on the movement of the patient on the scale it may take several seconds for the scale to lock onto the weight 5 Once a weight has been displayed while the patient is still on the scale Health o meter recommends performing a second weighing by pressing the REWEIGH button 6 After obtaining the patient s weight on the scale press the BMI button while the scale is on 7 The scale will prompt you to enter the patient s height Use the keypad A and P buttons to enter the patient s height Note When weighing in pounds the height is displayed in inches When weighing in kilograms the height is displayed in centimeter 8 Once height is keyed in press the ENTER button 9 The display will show the patients BMI 10 Press the ENTER button to return to the normal weighing mode of the scale 17 MAINTENANCE AA Maintenance The following pages provide instructions for maintenance cleaning calibrati
13. quired Phillips head screwdriver not included Allen wrenches included 1100KL ASSEMBLY INSTRUCTIONS CONTINUED Assembling the 1100KL Scale Refer to Fiqures 1 7 Caution It is recommended that the assembly be performed by two persons 1 Remove the scale platform from the carton and place scale platform on a flat level and dry surface 2 Locate and pick up the center handrail Find the load cell cable connector located at the bottom of the center handrail Untie it and pull it out the bottom see Figures 2 amp 3 3 Position the center handrail over the handrail supports on the platform and feed the cable through the handrail support hole located on the right handrail support in the platform Be sure not to pinch the cable see Figures 2 3 amp 7 4 Position the center handrail over the left and right handrail supports on the platform Fasten the handrail to the platform using 4 M8 1 25 x 3 8 screws B and 4 M8 washers E Use the 5mm Allen wrench to tighten the screws Do not over tighten see Figures 1 2 amp 4 5 Loosely attach the left and right side handrails to the center handrail using 4 M10 1 5 x 1 Y screws A Use the 8mm Allen wrench to fasten the screws see Figures 1 amp 2 Pull forward on the side handrails to tip the scale and gently place it face down on the floor Grasp the load cell cable protruding from the bottom of the base of the scale and feed it through the protective metal
14. r local regulations which apply to you for disposal of electronic waste or batteries Do not dispose of this device in the domestic waste stream 1100KL ASSEMBLY INSTRUCTIONS 7 Before Assembly Each 1100KL digital handrail scale is shipped disassembled in a single carton Carefully inspect the carton for shipping damage before unpacking If damage is found contact your shipper or a Health o meter Professional representative immediately at 1 800 815 6615 Claims must be filed with the shipper as soon as possible after receipt of the package The following information details what you will find inside the main carton as you unpack the parts for assembly To prevent scratching any components carefully remove each assembly from the carton and unwrap the packing materials Set the carton aside for storage To avoid damaging the scale parts when unpacking do not use a box cutter knife scissors or any sharp object to open the protective inner packaging Parts List 1 Scale platform 1 Center handrail 2 Side handrails 1 Small brown carton The small brown box contains e 1 Box containing the AC adapter e 1 Long white box e 1 User Information e 1 Display assembly The long white box contains 4 Feet 1 10mm Allen wrench 1 5mm Allen wrench 1 AC adapter holder 2 Pivot bracket screw covers 2 Plastic bag containing 2 Covers for Display Support Front amp Back o Hardware for assembly see Figure 1 Tools Re
15. rding to the units of measure used upon entering into the calibration path The following calibration assumes the scale is set to pounds and 400 Ib the default weight is employed as the calibration weight Scale Calibration Operator Action Display 1 Make sure the display is powered off then press and hold the U 01 followed by a 5 digit HOLD RELEASE button while pressing the ON OFF button idle scale count number 2 Press the ENTER button 3 Make sure there is nothing on the scale then press the ENTER Clear followed by button 0400 0LB 4 Use the gt and A buttons to set the calibration weight to a Shows 400 0 or entered value other than the default weight The calibration weight should calibration weight be as high as possible with 400 lb as a minimum calibration weight 5 Press the ENTER button Alternating Load followed by 400 0LB 6 Load the scale with the required weight Display increments showing raw weight data 7 Without touching or shaking the scale allow the display to SUCC or Err1 stabilize then press the ENTER button 8 If the calibration is successful the display will show SUCC and power off If the calibration is not successful the display will show Err1 and power off Contact customer service for an Err1 display 1 800 638 3722 19 TROUBLESHOOTING Troubleshooting Before contacting service personnel refer to the following instruc
16. rranty Cover Health o meter Professional scales are warranted from date of purchase against defects of materials or in workmanship for a period of two 2 years If product fails to function properly return the product freight prepaid and properly packed to Pelstar LLC see To Get Warranty Service below for instructions If the manufacturer determines that a defect of material or in workmanship exists the customer s sole remedy will be repair or replacement of the scale at no charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Please save your invoice or receipt Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover natural disast
17. s without notice O Pelstar LLC 2013 I5013485 2003 CERTIFIED P N UM1100KL Rev 3 080613 21
18. tions to check and to correct any failures Symptom Possible Cause Corrective Action Scale does not power on 1 Dead Battery 1 Replace batteries 2 Faulty electrical outlet 2 Use a different outlet 3 Bad power supply 3 Replace AC adapter Questionable weight or 1 External object interfering 1 Remove interfering object the scale does not zero with the scale from the scale 2 The display did not show 2 Ask the patient to get off the 0 0 before weighing scale zero the scale and begin weighing process again 3 Scale is not placed on a 3 Place the scale on a level level floor floor and begin weighing process again 4 Scale is out of calibration 4 Check weight with known weight value 5 Improper Tare 5 Place the item to be tared on the scale Press REWEIGH Once the weight of the item is displayed press TARE Place the patient and the tared item back on the scale Press REWEIGH again Weighing is performed but The patient is not sitting or Ask the patient to stand or sit the weighing process takes standing still still too long and the weight does not lock on the displayed The display shows Over The load on the scale Remove the excess weight and message exceeds the capacity use the scale according to its 1000 Ib 454 kg limits The display shows The batteries are discharged Replace batteries according to Lo bAtt message instructions 20 WARRANTY S Limited Warranty What does the Wa
19. tteries to avoid a safety hazard Disposal of batteries must be performed in accordance with the prevailing national regional or local regulations which apply to you 12 SETUP BATTERIES CONTINUED SCREW BATTERY COVER BATTERIES DISPLAY ASSEMBLY Fiqure 8 13 QUICK START OPERATING INSTRUCTIONS Keypad Capacity 1000 bX 2Ib 454kgX 1kg et ZERO PELEA gt ON OFF TARE PRETARE REWEIGH DEPRESS AND HOLD FOR PRETARE Figure 9 Description ON OFF Power scale on and off ZERO Zeros the scale prior to a weighing RE ZERO eros the weight value of the patient on the display until the button is pressed again to clear the value Also moves the cursor from left to right on the display for entering height and pretare value MIT a entry of height data to calculate patients Body Mass Index MIT a RECALL Recalls the previous weight TARE Tares out weight of an object on the platform TARE PRETARE PRETARE Prompts entry of a tare value that will be deducted from the weight on the platform Also releases tare weight returns display to zero Also used to increment height value and pretare value REWEIGH Allows repeated weighing of the patient without stepping off the scale Used to accept height value in BMI mode and tare value in PRETARE ENTER mode Also releases the recall value and BMI value 14 QUICK START OPERATING INSTRUCTIONS CONT Tare Function Whe
20. vided by Health o meter Professional Use of an unspecified adapter will void the warranty and can pose a serious safety hazard e Prior to using this scale inspect the AC adapter cord for cracking fraying or for broken bent plug prongs e Prior to using this scale ensure that the AC adapter is plugged into an outlet with the rated voltage appropriate for operation e Ensure that the AC adapter outlet is wired to a circuit breaker or other protected power source e Unplug the AC adapter and carefully store both the adapter and adapter cord before moving the scale e Ensure that the AC adapter and scale do not come in contact with liquids excessive temperature or excessive humidity e Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty e Do not transport the scale with any weight on the platform e Do not exceed recommended weight limit of 1000 Ib 454 kg for this scale e For accurate weighing this scale must be placed on a flat stable surface e For accurate weighing verify before each use the proper operation according to the procedure described in this manual e Do not use in the presence of flammable or explosive materials e For accurate weighing if the Lo bAtt indicator activates replace the batteries or switch to the AC adapter as soon as possible e When replacing inserting batteries be sure to use all new batteries e