Home
        Alarms Notification Module
         Contents
1.   3   Advanced operation       m Silencing the keys    It is possible to enable disable the keys    sound         Press key 1 for 5 seconds  to enable disable  the sound        m LED suppression    It is possible to suppress the display of the LEDs status when the  system is armed         When the system is disarmed  press key 2 for  5 seconds        4  Maintenance and troubleshooting       v A false alarm is received by a system sensor    The sensor is probably faulty  choke the zone and contact the  installer     Y   have forgotten the user code  Retrieve the factory set code  see page 11      v Ihave lost a transponder key    Cancel all transponders and re register the ones to be used   see page 12      14    EI legrand       World Headquarters and  International Department  87045 LIMOGES CEDEX FRANCE  1 335 55 06 87 87   Fax  33 5 55 06 74 55  www legrandelectric com    Installer stamp          5      E     5  E  E  g  2         5     EI  E  E  5  2           E     y  3  3  E  2      EI  z  E     2  5  5  E    and modality  the changes brought to the same        
2.  Basic operation       v Anti tamper alarm v Alarm stop      Ifthe Alarms Notification Module is tampered      stop an alarm before this is sent to the Handset and to the Switch   with  a notification issenttotheHandsetand board  within the time limit specified by the configuration   to the Switchboard  At the same time the    P     LED will turn red and start flashing slowly      Press the C    key      To remove the notification  reset the tamper           Enter the user code  default 12345    ing contact and arm the system          Run an enabled transponder key by the  reader        10    3   Advanced operation       m The code and the transponders    The Alarm Notification Module can accept only one user code  5 nu   meric digits  and 10 transponder keys    The code  factory set to 12345  can be changed at any time  To replace a  transponder key after the maximum number of keys has been reached   all keys need to be deleted and then re registered     v Customizing the user code    Press the needle key    P        Enter the code     First activation  12345    Subsequent activations  personal code    Enter the new code  eg   99999   The device will emit a sound     Re enter the new code  eg   99999     If the code has been re entered correctly   2 beep will be heard and the LED will go off       If the code has been re entered incorrectly  1  1 long beep will be heard and the procedure  will need to be repeated        11    v  Retrieving the factory set code    Reinstating
3.  be generated     v With the user code      Press the C    key      Enter the user code  default 12345    to  change the mode of operation  Once the  code has been entered  a confirmation beep  will be heard      short beep  correct code entered    long beet  wrong code entered      In both cases  the device shows the active in   puts with their assigned LEDs on  red        The information of the system status  Armed   Disarmed  is provided by the  P  LED   Off  system armed  ON green  system disarmed          v With the transponder key    Press the C    key      Runan enabled transponder key by the read   er  within 4 seconds         n both cases  the device shows the active in   puts with their assigned LEDs on  red        The information of the system status  Armed   Disarmed  is provided by the  P  LED   Off  system armed  ON green  system disarmed    2   Basic operation       m Inputs choking    The enabling disabling status of the inputs  choking  can only be  changed when the system is disarmed    The Alarms Notification Module is capable of distinguishing between a  connected and a non connected  not detected   LED off  input  Anon  connected input cannot be enabled     V Inputs Enabling Disabling      Press the key of a disabled input  green LED   to enable it  red LED        Press the key of an enabled input  red LED  to  disable it  green LED        Pressthe 0 key to enable disable all inputs      Press a 1  time to Enable      Press a 2  time to Disable    m Alarm
4.  of the factory set user code  if the current code has been  forgotten  can be done following the procedure below  provided  that a registered transponder key is available  otherwise contact the  installer          5    Press the needle key  P      Run an enabled transponder key by the reader   The  P  LED turns red      Press the C    for 5 seconds     The LEDs of keys 1 and 2 start flashing       Press key 2        The  P  LED turns orange and starts flashing     The factory set code 12345 has now been  activated     3   Advanced operation       v Enabling the transponder key        Press the needle key    P                    Enter the code     First activation  12345      Subsequent activations  Run an enabled  transponder key by the reader     The  P  LED turns red     Run a transponder key to be enabled by the   reader     Ifthe transponder key is recognised  it means  that it can still be registered  the maximum  number of keys is 10   In this case the device  will beep twice and the LED will go off       Otherwise the device will emit 1 long beep        The procedure will then need to be repeated     12    v Deleting Transponder keys             Press the needle key              Enter the code or run an enabled transponder  key by the reader       The    P    LED turns red     Press the C    key for 5 seconds     The LEDs of keys 1 and 2 start flashing     Press key 1        The    P    LED turns orange and starts flashing   All transponder keys have been cancelled   
5. User manual                   5739 54  5739 55          Part  U3628A   11 08 01 PC LI legrand    Contents    1  Introduction  m The Alarms Notification Module  v User interface  v LEDs light signals  v    P  LED light signals  v Configuration table    Anup    2  Basic operation  m Arming Disarming   v With the user code   v With the transponder key  m Inputs choking   v Inputs Enabling Disabling  m Alarms handling   v Burglar alarm   v Technical Fault Alarm   v PANIC Alarm   v  Anti tamper alarm   v Alarm stop    O Ove   00 AA NNN    3  Advanced operation   m The code and the transponders  v Customizing the user code  v Retrieving the factory set code  v  Enabling the transponder key  v Deleting Transponder keys   m Silencing the keys   m LED suppression       W W NN        4  Maintenance and troubleshooting    1   Introduction       m The Alarms Notification Module    The Alarms Notification Module is a safety device  capable of notifying  burglary  technical faults and panic alarms locally and send them to the  Video Handset and to the Switchboard  where they will be displayed   The Alarms Notification Module is capable of handling 8 independ   ent inputs and one additional input dedicated to panic alarm signals   PANIC     Each input can be enabled or disabled  Its state is indicated by the  corresponding LED    The system can be armed disarmed by entering the 5 digit numeric  code or by using a transponder key                             v User interface        P  key  wi
6. hat generated the  alarm  with the system disarmed         The Alarms Notification Module carries outthe  following operations       If the cause that generated the alarm is not re   Ed   solved  the visual notification is not removed       If the cause that generated the alarm has been   resolved  the visual notification is removed         The device will also send a technical fault  alarm reset notification to the Handset and to  the Switchboard        v PANIC Alarm  a         The LED 9  assigned to the alarmed input  flashes guickly and the device emits an acous       tic signal that will last 10 seconds        After the waiting time delay has expired  10 seconds   the alarm  notification is sent to the Handset and to the Switchboard  The alarm  response handling procedure is then referred to the Caretaker s Lodge  Switchboard         After the alarm notification has been sent   the acoustic signal stop and the LED s flash   ing will become slow         Toremovethe visual notification of the alarm   press the key of the input that generated the  alarm  with the system disarmed      The Alarms Notification Module carries outthe  following operations       If the cause that generated the alarm is not re   solved  the visual notification is not removed         Ifthe cause that generated the alarm has been  resolved  the visual notification is removed         The device will also send a technical fault  alarm reset notification to the Handset and to  the Switchboard        2  
7. ls for the needle key LED         System armed  the state of the module when technical fault and  burglary alarms can be generated         System disarmed  state of the Module when technical fault and bur   glary alarms are not generated  panic and tamper alarms remain  active   The state of the inputs  enabled disabled  can be changed  when the module is in this mode       Arming phase  it shows the passing of the output timing        Anti tamper alarm  notification that the Module has been tam   pered with        Code transponder management  the set up procedure for the user  code or the transponder keys have been activated         Installation  the start up procedure for the Module operation has  been activated              System System Arming Anti tamper Codes  Installation  armed disarmed phase alarm transponders  management        VX Se       x 2   O     IA  Off Green Red Red Deep Orange  flashing flashing Red  quickly slowly                         1   Introduction       v Configuration table    CONFIGURATION OF THE ALARMS NOTIFICATION MODULE                      TO BE COMPLETED BY THE INSTALLER    2   Basic operation       m Arming Disarming  The Alarms Notification Module can operate in 2 main modes         Disarmed  when in this mode  technical fault and burglary alarms  are not generated  panic and tamper alarms remain active   The  state of the inputs  enabled disabled  can be changed when the  module is in this mode       Armed  when in this mode  all alarms can
8. s handling    The Alarms Notification Module notifies the following types of  alarms       Burglar  when an enabled burglary input is activated     Technical fault  when an enabled technical fault input is activated       Panic  when input no  9 is activated or the PANIC key on the keypad  is pressed       Tampering  when the anti tamper protection is open     v Burglar alarm    E    After the waiting time delay has expired  see configuration table  on page 6  the alarm notification is sent to the Handset and to the  Switchboard             ES        The LED assigned to this input flashes quickly  and the device emits a short acoustic signal  that repeats every second       After the alarm notification has been sent   the acoustic signal stop and the LED s flash   ing will become slow         Toremove the visual notification of the alarm   press the key of the input that generated the  alarm  with the system disarmed         2   Basic operation       V Technical Fault Alarm           After the waiting time delay has expired  see configuration table    on page 5  the alarm notification is sent to the Handset and to the  Switchboard         The LED assigned to the technical fault input  flashes quickly and the device emits a short  acoustic signal that repeats every second         After the alarm notification has been sent   the acoustic signal stop and the LED s flash   ing will become slow     E      Toremove the visual notification of the alarm   press the key of the input t
9. th LED         Transponder    reader PANIC key           LED  Leds 1 8 provide alarm notification from the burglary and tech   nical faults inputs  LED 9 is dedicated to the panic alarm notification       Needle key with LED  this key gives access to the starting up proce   dure  Code Transponder set up and Resetting of the Module         PANIC key  it generates an emergency call  even with the system  disarmed       Transponder reader  Transponder keys reader       Keypad  numeric keys for entering the user code  The C    key gives  access to the arming disarming procedure     1   Introduction       v LEDs light signals    The following tables describe the LEDs light notifications of the states  of the corresponding inputs       Input not detected  input not connected   An input not connected cannot be enabled       Input enabled  input connected and enabled for alarm transmis   sion       Input disabled  input connected but alarm transmission disabled     Input alarmed  input connected  enabled and alarmed       Input alarmed after transmission of signal  the input is still  alarmed after sending the alarm notification to the Handset and to  the Switchboard        Input not Input Input Input Input alarmed  detected enabled disabled alarmed after alarm  notification    transmission    S       O       AN                Off Red Green Red flashing Red flashing  quickly   slowly  Buzzer on                      v    P    LED light signals  The following table show the light signa
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Bauer Bedienungsanleitung_Rainstar_E11_E51_dtsch  平成24年 第669号    Copyright © All rights reserved. 
   Failed to retrieve file