1. 14 Power Inverter 400 MW 1204 Owner s Manual For safe and optimum performance the Power Inverter must be used properly Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Disclaimer While every precaution has been taken to ensure the accuracy of the contents of this guide KISAE Technology assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your KISAE Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers Modified Sinewave series MW 1204 Power Inverter 400W Document Part Number MU MW1204 Rev 1 Service Contact Information Email info kisaetechnology com Phone 1 604 320 7857 Web www kisaetechnology com Page 2 xo Hr d YP YS Table of Contents INTRODUCTION u u u PRODUCT DESCRIPTION eo innne Aaa FED INSTACCATION u e sans TROUBLESHOOTING u uu u ul u allo rtr tires SPECIFICATIONS mtt ERE LE WARRANTY Page 3 INTRODUCTION Thank you f
2. Tighten the nut on each DC terminal e Insert the light plug of this cable to the fused 12V lighter plug socket e Unitis ready for use Using the Battery clips cable CAUTION Please be sure all the connections are tight before the use of the unit e X Attach the red ring type connector to the positive DC terminal red on the power inverter and connect the black ring type connector to the negative DC terminal black on the Power inverter e Attach the negative black clip to the negative battery terminal e Attach the positive red clip to the fuse or circuitry breaker of the 12V battery bank as indicated on Typical Wiring block diagram of the Power Inverter on page 5 e Unit is ready for use Test the Power Inverter e Turn unit on by using the On Off button on the unit The Power light turns on indicating the KISAE Power Inverter is ON AC output is now available e Plug in a small AC load like a 25W table lamp or small appliance to the AC socket to verify AC is available e The unit is successfully installed and functioning properly UNIT OPERATION WARNING RISK OF EQUIPMENT DAMAGE e Do not plug surge protected power bars into the unit s 120 VAC outlets The surge protected components on the surge protected power bar may not like the modified sine wave output generate by the inverter e Do not connect an AC power source like utility power or generator to the unit 120 VAC outlets Turn ON and OFF
3. Page 9 purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year from the purchase date manufacturer will repair the unit or at its option replace it free of charge If the unit is repaired new or reconditioned replacement parts may be used at manufacturer s option A unit may be replaced with a new or reconditioned unit of the same or comparable design The repaired or replaced unit will then be warranted under these terms for the remainder of the warranty period The customer is responsible for the shipping charges on all returned items LIMITATIONS This warranty does not cover accessories such as adapters and batteries damage or defects result from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire and flood If your problem is not covered by his warranty call our Customer Service Department at info kisaetechnology com or 1 604 320 7857 for general information if applicable Page 10
4. connection is not covered by the warranty e Connect one end of the negative DC input cable to the Power Inverter DC negative terminal black Connect the other end of the negative DC input cable to the battery negative terminal e sure the Disconnect Switch is in the OFF position e Connect one end of the positive DC input cable to the Power Inverter DC positive terminal red Connect the other end of the positive DC input cable to one of the terminal of the Disconnect Switch e Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder e Connect a DC input cable between the other terminal of the fuse holder and the battery positive terminal Install the selected fuse to the fuse holder e Turn Disconnect Switch to ON position Connect unit with optional accessories Battery clips cable or Lighter plug cable Using the Lighter plug cable CAUTION Due to the limitations of the 12V lighter plug socket in vehicles the unit should be used with the DC cable with lighter plug only to supply AC power to products that require 150W 120VAC 1 3 A or less If the appliance requires more than 150W use the optional DC cable clips for battery connection Attach the red ring type connector to the positive DC terminal red on the power inverter and connect the black ring type connector to the negative DC terminal black Page 6 on the Power inverter e
5. that applies to this unit and it sets forth all the responsibilities of KISAE There is no other warranty other than those described herein Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the duration of this warranty This unit is warranted to the original purchaser only to be free of defects in materials and workmanship for one year from the date of purchase without additional charge The warranty does not extend to subsequent purchasers or users Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price of the unit under any circumstances Incidental and consequential damages are specifically excluded from coverage under this warranty This unit is not intended for commercial use This warranty does not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power sources RETURN REPAIR POLICY If you are experiencing any problems with your unit please contact our customer service department at info kisaetechnology com or Phone 1 604 320 7857 before returning product to retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of
6. connected along the DC positive line is required e Select a fuse or circuit breaker with a minimum of 60 ADC e Based on the size of the battery bank chosen on the 12V Battery Bank above determine the overall short circuit current rating of the battery bank from the battery manufacturer The fuse or circuit breaker chosen has to be able to withstand the short circuit current that may be generated by the battery bank Disconnect Switch e Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit breaker from the above e he Disconnect Switch is used to disconnect the DC power between the power inverter and the battery bank during service maintenance or trouble shooting DC Input Cable Use of low resistance wire is required for all the DC connections between the inverter and the battery bank e Uses minimum 10 AWG wire with maximum cable length of 5 feet Installing the Power Inverter System WARNING Electrical Shock Hazard The unit On Off switch does not disconnect the DC power from the battery Use the DC Disconnect Switch or disconnect the DC input cables connection to disconnect the DC power from the battery before working on any circuits connected to the unit Failure to follow these instructions can result in death or serious injury Power Inverter DC Input Connection CAUTION Reverse the DC Input terminal will damage the unit and cannot be repaired Damage caused by reverse polarity
7. less Phone 150 hrs Clock Radio Ww _ 100 hrs Table Lamp 40W 60W 27 hrs 18 hrs Freezer 8 8 cu ft 15 hrs 20 LCD TV 100W 11 5 hrs Sump Pump 1 2 hp 350W Not applicable surge too high 5 TROUBLESHOOTING To trouble shoot the unit please note the error code display on the main unit and review the Understanding the Error Codes in section 4 Problem Solution No AC output and Power indicator is No power to inverter Check fuse or the Disconnect switch if off installed is either blown or turn OFF indicator is ON shutdown correction and reset unit Products connected Products connected to unit Products are not compatible with the to unit malfunction or do not accept modified modified sine wave output generated by overheat sine wave output the KISAE Power Inverter See AC Load on Power Inverter in Section 4 Page 8 6 SPECIFICATIONS Note Specifications are subject to change without notices AC Output Power AC Output Current AC Surge Power Peak AC Output Voltage AC Output Waveform Nominal DC Input Voltage No Load battery draw Under Voltage Recovery 11 8 VDC Over Voltage Shutdown 15 5 VDC Safety and Environmental Certified to CSA C22 2 no 107 1 Agency Markings Operating Temperature Storage Temperature Relative Humidity Operating Altitude Up to 9 843ft 3000 meters above sea level 7 WARRANTY One Year Limited Warranty The limited warranty program is the only one
8. n contact with eyes If this occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention e Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system e Keep unit away from moist or damp areas e Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery or another electrical tool that may create an explosion WARNING Shock Hazard Keep away from children e Avoid moisture Never expose unit to snow water etc e Unit provides 120 VAC treat the GFCI output socket the same as regular wall AC sockets at home WARNING Explosion hazard e DO NOT use the KISAE Power Inverter in the vicinity of flammable fumes or gases such as propane tanks or large engines e AVOID covering the ventilation openings Always operate unit in an open area e Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit LIMITATIONS ON USE Do not use in connection with life support systems or other medical equipment or devices Page 4 PRODUCT DESCRIPTION The KISAE Power Inverter package includes the items list below e Power Inverter base unit MW1204 e Owner s manual P N MU MW1204 INSTALLATION WARNING KISAE Technology recommends that all wiring be done by a certified technician or electrician to ensure adherence to the applicable electrical safety wiring
9. or purchasing the KISAE Power Inverter With our state of the art easy to use design this product will offer you reliable service for providing AC power for your home cabin RV or Trailer The KISAE Power Inverter can run many AC powered appliances when you need AC power anywhere This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully IMPORTANT SAFETY INFORMATION This section contains important safety information for the KISAE Power Inverter Each time before using the KISAE Power Inverter READ ALL instructions and cautionary markings on or provided with the inverter and all appropriate sections of this guide The KISAE Power Inverter contains no user serviceable parts See Warranty section for how to handle product issues WARNING FIRE AND OR CHEMICAL BURN HAZARD e Do not cover or obstruct any air vent openings and or install in a zero clearance compartment WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY When working with electrical equipment or lead acid batteries have someone nearby in case of an emergency e Study and follow all the battery manufacturer s specific precautions when installing using and servicing the battery connected to the inverter e Wear eye protection and gloves e Avoid touching your eyes while using this unit e Keep fresh water and soap on hand in the event battery acid comes i
10. regulations and installation codes Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning your KISAE Power Inverter Installation please consider the following e he KISAE Power Inverter base unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants e When placing the unit allow a minimum of three inches of space around the unit for optimal ventilation Understanding the unit features AC Output Front Panel OUTPUT 120 VAC 60 HZ E gt Power indicator TD wu WP Y Fault indicator On Off Switch j DC Input Terminals opening ys Amere damage Material Prepare for Installation Typical Wiring block diagram of the Power Inverter 12 V Battery Bank Pos Disconnect Fuse or Circuit Power Inverter Switch Breaker Charger system MW 1204 sold separately is required to charge the battery bank when battery is discharaed Page 5 12V Battery Bank e The use of deep cycle battery is highly recommended for power inverter application e For battery size you need to identify how much you will be using them between charges KISAE do recommends you purchase as much battery capacity as possible See more on Battery Run time and Load in Section 4 Fuse or Circuit Breaker e DC rated fuse or DC rated circuit breaker
11. the unit e Toggle the On Off switch to ON position to turn unit ON e Power indicator will turn green 120 VAC is available e Toggle the On Off switch to Off position to turn unit off Power indicator will turn off Understanding the LED indicators Power indicator Indicator turn on indicate unit is ON Fault indicator Indicator turns on indicate fault was detected Unit has shutdown To reset unit remove the fault condition and reset unit by using the toggle switch and turn unit off and on again Understanding the fan operation The fan on the unit will automatically turns on when it sense the internal temperature of the unit reach to its preset level AC Load on Power Inverter Although the Power Inverter can provide high surge power up to two times the rated output power some appliances may still trigger on the inverter protection system A higher power inverter is required for those appliances Some appliances like speed controllers found in some fans power tools and some power tools AC charger may not like the modified sine wave generate by the inverter those appliances may not work or may be damaged if they are connected to the inverter If you are unsure about powering any device with the inverter contact the manufacturer of the device Estimate Run time on Load Page 7 Following run time is an estimate based on using 12V 120AH battery bank for reference Actual run time may vary Cord

Download Pdf Manuals

image

Related Search

Related Contents

Informe final D03I1039    piece6_e-1386_re_gle.. - Ville de Gonfreville l`Orcher  à 8 - La Caravane  User manual - Russell Hobbs  Manual Del Propietario  Lanzar Car Audio OPTIX3B User's Manual  UNICORN start 1.0 User Manual  Centre de langue française de langue française pour étrangers pour  Soundmaster PDB1800  