        iShutter Manual - Pepper-One Certification of Z
         Contents
1. 1  size 1 byte     One push button  One button is used  chose any   press while moving up and down stops  while stopped  moves to opposite direction to previous    Two buttons with neutral position  Up click moves up if stopped and stops if moving down  Down click moves  down if stopped and stops if moving up  Hold Up Down moves in up down  Release stops     Two toggle switch  Switch to Up Down moves up down     Two paddles with Power and Direction  Hold Up button to move blinds up  If Down button is pressed  blinds  will move down  Release Up button to stop     Two paddles with Power and Direction toggle  Hold Up button to move blinds up  Down button toggle  between up and down motion     Values    0 One push button  default    1 Two paddles with Power and Direction   2 Two toggle switch   3 Two buttons with neutral position   4 Two paddles with Power and Direction toggle    Automatically close after  parameter No 2  size 2 bytes     If not zero  automatically switch off   close blind after a user defined time    Values     0 Disabled  default     1     65535 Close after this time  in s     What to do on RF off command  parameter No 3  size 1 byte     Defines how to interpret RF Off command  Can be used in conjunction with Auto Close function  Ignore   to  open the door by motion detectors and close it back after some amount of time  in case of multiple motion  detectors each would try to open that would break logics  Open   to open on both On and Off paddle press  on the re
2. Time to go from closed to opened state  Used to estimate the current level  Note that in permanent motion  mode the reported value would be closed or opened  while all Basic and Multilevel Set values  1   99  255   would open except 0 value that would close     Values     0 keep in permanent motion    1     255 in s  default is 60 s     Node Id of the blocking device  parameter No 12  size 1 byte     Id of the blocking device  Commands from this device would be interpreted not as Open Close  but as  block unblock  Useful with door opening detector  if the door is open  block the blind not to break shades  while they move     Values   0 disabled  default     1     232 Node ld of the blocking device    On which command from blocking node to enable the protection  parameter No 13  size 1 byte     Defines which command from blocking device to interpret as closed door and hence  unprotected     Values   0 on    On     default   1 on    Off       Invert Open and Close relays  parameter No 14  size 1 byte     Allow exchanging open and close relays if blind control is wired to the motor incorrectly    Values   0 No  default   1 Yes    Reset to factory Default  parameter No 254  size 1 byte     Attention  This will delete all your configuration  but the device will remain in the network  Handle with care     Values     254 Execute reset    4 5 Child Protection    The device can be turn into a child protection mode  This means that the local operation of the device is not  possible  Th
3. e child protection mode MUST be turned on wirelessly  However it is possible to unlock the  device for local operation with a triple click  The unlock state will last for 5 seconds     4 6 Z Wave Specific Device Information    4 6 1 Z Wave Device Types    e Generic  Multilevel Switch  e Specific  Motor Control Class C    4 6 2 Supported Command Classes     e All Switch  V1    e Association  V2    e Basic  V1    e Binary Switch  V1    e Configuration  V1    e Indicator  V1    e Manufacturer Specific  V1    e Multi Channel Association  V2   e Multilevel Switch  V3    e Node Naming and Location  V1   e Protection  V1    e Version  V1    e Scene Activation  V1    e SceneActuatorConf  V1     4 6 3 Controlled Command Classes    e Multi Channel  e Multilevel Switch    e Scene Activation    5 Electrical circuit     6 LED Modes    e OK   2 seconds  e Failed   8 blinks  e Notin Network   Permanent blinks    7 Technical data    e Receiving frequency  868 42 MHz   e Switching capacity  resistive 1 800 W    e Operating voltage  230 V  50 Hz   e Dimensions  H x W x D   51 x 46 x 31 mm    e Operating temperature  0  C to  40  C    
4. groups  A PC gateway controller gives you the most comfortable and powerful way to  configure your device     Association groups     1  Click or hold down up button controls devices in Association group No 1    2  Reports on Shutter state change will reported to devices in group No 2    All groups support up to 10 nodes and 10  node  channel  pairs     If the device is associated to a static controller it can be used to activate scenes in this controller  If the  configuration parameter  6 is set to the value 2 the following scene activation commands are sent to the    target nodes of the association group   A Scene 1  On moving Up  A Scene 2  On stopping    A Scene 3  On moving Down    4 4 Z Wave Configuration    Z Wave products are supposed to work out of the box after inclusion  however certain configuration can  adapt the function better to user needs or unlock further enhanced features     IMPORTANT  Controllers may only allow configuring signed values  In order to set values in the  range 128   255 for parameters 4  10  11 and 12 the value sent in the application shall be the desired  value minus 256  For example  to set parameter 4 in Window Blind to 200 s it may be needed to set a  value of 200 256  56  Similar rule applies to parameter 2  to set values in range 32768   65535 use  value equal to desired value minus 65536  For example  to set auto switch off period to 10 hours    36000 s it may be needed to set a value 36000 65536  29536     Buttons Mode  parameter No 
5. iShutter Manual    1 General Information about Z Wave    Reliable    Generally radio systems build a direct link between the transmitter and the receiver  The radio signal is  attenuated by every obstacle along its path  in the household e g  wall  furniture etc   In the worst case the  radio system ceases to function  The advantage of the intelligent Z Wave system is the so called routing  function  All mains powered devices of Z Wave not only act as transmitter or receiver but also simultaneously  as    repeater     Should a direct radio link between the transmitter and the receiver not be possible   communication will be established with the assistance of other devices     Communicative    Z Wave is a bidirectional radio system  This means that a signal is not just sent but also a feedback  confirming the reception of the signal occurs automatically  The safety of transmission of the Z Wave radio   bus technology is comparable with that of a wire linked bus system     Trouble free     Z Wave transmits at a regulated frequency band with a frequency of 908 MHz  US    868 MHz  EU   Every Z   Wave network has its own unique network identification  Therefore  it is possible to operate two or more  independently operating networks in a room or home without any interference  Troubles that can be caused  by other devices  as is the case in open  non regulated frequencies  e g  433 MHz  are excluded     Interoperable     Z Wave is an international standard that ensures that product
6. ly in built in sockets is possible  As a result of  the compact design  the iShutter is supposed to we either installed as a separate product in a wall box or  behind a traditional wall switch     4 Wireless Functions     Z Wave    4 1 Z Wave Network Inclusion    In order to use the device by a controller the device needs to be included into a Z Wave network  Only  device that are part of the same network can send commands to the device     1  Follow the instructions on your Z Wave Primary or Inclusion Controller to include  add  a Z Wave  device    2  Triple press Up or Down button   3  The LED going on for 2 secs indicates success  Failure is indicated by 8 blinks     4  Your device is ready to work     4 2 Z Wave Network Exclusion    In order to remove the device from a Z Wave network the following steps have to be performed     1  Follow the instructions on your Z Wave Primary or Inclusion Controller to exclude  remove  a Z   Wave device    2  Triple press Up or Down button   3  The LED going on for 2 secs indicates success  Failure is indicated by 8 blinks   4  Note  All configurations and associations stored in the device are deleted during Exclusion process    5  Your device can now be removed physically     Attention  Removing the device from the network means that it is turned back into factory default  status     4 3 Z Wave Associations    The iShutter supports two association groups  Refer to your Z Wave Controller instructions to add devices in  these association 
7. mote and close after some amount of time  Button close click will still work  if button operations are  not disabled   Note that Dim Down command will still begin close motion     Values    0 Switch off  default    1 Ignore   2 Switch on   3 Open if close  otherwise close    Typical click timeout  parameter No 4  size 1 byte     Typical time used to differentiate click  hold  double and triple clicks    Values     1     100 in 10 ms units  default is 50  that is equivalent to 500 ms     Invert buttons  parameter No 5  size 1 byte     Values   0 No  default   1 Yes    Action on button press or hold  parameter No 6  size 1 byte     Defines which command should be sent to Association group on button press or hold  Scene mode will send  1 for Up event  2 for Stop  3 for Down     Values   1 Switch On  Off and dim using Multilevel start stop  default   2 Send Scene    LED mode  parameter No 7  size 1 byte     Set LED indication mode    Values    0 Disabled   1 Show working state  default   2 always on   3 show opened state   4 Indicator Command Class    Full close time  parameter No 10  size 1 byte     Time to go from opened to closed state  Used to estimate the current level  Note that in permanent motion  mode the reported value would be closed or opened  while all Basic and Multilevel Set values  1   99  255   would open except 0 value that would close     Values   0 keep in permanent motion    1     255 in s  default is 60 s     Full open time  parameter No 11  size 1 byte     
8. s from different vendors work together  seamlessly  The iShutter was certified by the Z Wave Alliance to guarantee this interoperability     2 Before Installation Setup    Please read carefully the enclosed user manual before installation of the radio actuator  in order to ensure an  error free functioning     ATTENTION  only authorized technicians under consideration of the country specific installation  guidelines norms may do works with 230 Volt networks  Prior to the assembly of the product  the  voltage network has to be switched off and ensured against re switching     The product is permitted only for proper use as specified in the user manual  Any kind of guarantee claim  has to be forfeited if changes  modifications or painting are undertaken  The product must be checked for  1    damages immediately after unpacking  In the case of damages  the product must not be operated in any  case     If a danger free operation of the equipment cannot be assured  the voltage supply has to be immediately  interrupted and the equipment has to be protected from unintended operation     3 Installation    The iShutter can be controlled both by using external analog switches  as well as wireless wall switch or  remote control  The assembly must take place in a voltage free state by an authorized electrical technician   Turn off the power supply prior to the mounting and confirm the absence of voltage with a 2 pin voltage  checker  Protect your installation from re switching  An assemb
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
T-SKY (K690M)  Homelite UT15550B Tiller User Manual  Tokina BH-725  User Manual Coach Watch W226  PARI ネブライザー  QSS_Fiscal_Year_Transition_Training_2011  1.3-1 CHRYSO Tard CE  Whirlpool RCS3004RS01 User's Manual  brat user manual 1 2 1  ISDN-10 - HUIT Services Dashboard    Copyright © All rights reserved. 