Home
- Centurion Systems
Contents
1. any place where items may fall on it When transporting ensure that it is placed in a secure area unlikely to move around and away from your animals The generator may be cleaned with a damp cloth and a mild detergent as necessary The applicators can be cleaned with isopropyl alcohol and cotton swabs and treatment heads should be cleaned after each treatment When treating open wounds hold the applicator approximately 1 4 1 cm away from the skin surface Disposal Considerations Statutory regulations may apply to disposal of this product Please contact your distributor or the manufacturer for disposal instructions Back to top 12 Service Note There is no user serviceable parts in the Centurion Laser Shower system Any attempt to open any of the parts contained in this system will void the warranties and could possibly result in hazardous radiation exposure If a problem is encountered return the system to the nearest service centre for repair Centurion Laser Shower Regulatory ISO 13485 2003 Compliance 93 42 EEC Class IIb NB 0366 CE Mark Health Canada Class II Medical Device License 14434 FDA CDRH compliance 21CFR 1040 10 and 1040 11 Dimensions Generator Only 178mm x 171mm x 76mm 7 x 6 3 4 x3 Carrying bag 381mm x 229mm x 216mm 15 x9 x 8 1 2 Boxed 460mm x 394mm x 320mm 18 x 15 1 2 x 12 1 2 Weight System in Bag 4 0Kg 9Ib Boxed 5 5Kg 12Ib Power Supply 9 6V R
2. indicating that the laser is operating and the time on the Logic Generator digital display see Diagram 1 Feature 2 will begin to count down Pressing the ON OFF button on the applicator will pause the treatment the timer will stop counting but will retain the treatment time remaining Pressing the ON OFF button again will resume the treatment When the treatment time is completed the head will automatically shut off and the timer will reset to the default 15 minutes for the next treatment Superfine Treatment Applicator Diagram 3 Superfine Treatment Applicator Ei R 1 On Off Switch 4 Laser Information Label 2 Emission Indicator 5 Visible Laser Radiation Warning Label 3 Service Indicator 6 Aperture Please ensure the laser aperture is pointed away from your eyes and the eyes of the animals under treatment Referring to Diagram 3 press the ON OFF button 1 A yellow light will illuminate 2 indicating that the laser is operating and the time on the Logic Generator digital display see Diagram 1 Feature 2 will begin to count down Pressing the ON OFF button on the applicator will pause the treatment the timer will stop counting but will retain the treatment time remaining Pressing the ON OFF button again will resume the treatment When the treatment time is completed the head will automatically shut off and the timer will reset to the default 15 minutes for the next treatment Back to top 8 Superfine Tr
3. is required by older style units is not required in the operation of the Centurion Laser Shower Effects of Laser Light on Tissue Understanding the five primary actions of laser light on tissue is helpful for proper use of the Centurion Laser Shower 1 Accelerated Tissue Repair The action of laser light is quite similar to photosynthesis where plants manufacture food from carbon dioxide and water using light energy to achieve chemical energy Photons of light from a laser penetrate deeply into tissue and power the synthesis of adenosine triphosphate ATP In other words photons of light energy are converted to chemical energy at the cell membrane ATP acts as a major carrier of energy from one reaction site to another in all living cells Increases in ATP resulting from laser light stimulation increases the energy available to the cell so that the cell can metabolize more quickly Nutrients can be taken in and waste products eliminated at a higher rate The result is an acceleration of repair to the cells comprising tendons and ligaments connective tissue with exposure to laser light 2 Rapid Formation of Collagen Approximately 80 of a horse s body is comprised of collagen This essential fibrous protein is required to replace old tissue or repair tissue injuries The most common example of collagen is Back to top 2 the clear sticky substance found around open wounds The fibroblast cells found in connective tissue
4. Front View amp CENTURION LASER SHOWER oE L SUPER FINE SUPER ULTRA aa FINE WIDE Os VETERINARY USE ONLY 1 Treatment Selection Switch 7 Low Battery Indicator 2 Timer with Digital Display 8 Recharge Indicator 3 Superfine Head Socket 9 Insulated Charger Jack 4 Ultra Wide Head Socket 10 Laser Information Label 5 Test Area 11 Visible Laser Radiation Warning Symbol 6 Laser Test Indicator Lamp 12 Usage Restriction Label Generator Operator Instructions Reference Diagram 1 1 Place the long strap of the logic generator around your neck so that the unit hangs in front of you or place over your shoulder to maximize movement when treatments are in progress For the protection of your eyes please ensure that you are wearing the supplied safety glasses 2 Select the desired treatment applicator Locate the appropriate socket for the treatment applicator Superfine and Superfine with Acupuncture Point Finder must connect to the socket Back to top 6 marked Superfine 3 Ultra Wide must connect to the socket marked Ultra Wide 4 Lining up the pin arrangement between applicator head connector and socket push the connector fully on to the socket Turn the sleeve of the connector clockwise until it is firmly into place 3 Turn the key on the Treatment Selection Switch 1 to the position matching the chosen treatment applicator The LED light will illuminate over the selected output socket A 15 minute timin
5. Laser Shower Operating Manual The Therapy Specialists 0366 Section 1 Section 2 Section 3 Section 4 Section 5 Introduction Effects of Laser Light on Tissue Equipment and Basic Safety General Safety Notes Information amp Warning Labels Found on Product Laser Shower Operation Logic Generator Unit Generator Operator Instructions Ultra Wide Treatment Applicator Superfine Treatment Applicator Superfine Treatment Applicator with Point Finder Point Location with the Point Finder Care amp Maintenance Testing Charging Care amp Cleaning Disposal Considerations Technical Data 10 11 11 11 12 12 12 13 13 14 Section 1 You have just purchased the most user friendly and up to date veterinary laser therapy technology available the Centurion Laser Shower Congratulations on your selection The Centurion Laser Shower operates by emitting laser light in a continuous shower at multiple frequencies A 785 NM wavelength has been incorporated into the Laser Shower in response to research showing the most effective penetration of laser light The effective average power directed toward an injured area is increased through multiple frequency targeting and the use of aluminum Galion Arsonite continuous wave laser diodes The shower effect allows for the treatment of many diverse indications ranging from surface injuries to deep seated soft tissue injuries Correct frequency selection as
6. an acupuncture point You may have to carry out several measurements before you find the point Extremely moist skin or an extremely high atmospheric humidity may lead to faulty results Acupuncture points that lie very deep may be challenging to find While the measurement is very accurate if the acupuncture points are located relatively close together the point finder indicator light may illuminate on the periphery of either point A second conductance measurement may be necessary NOTE The illumination of the red Indicator light Feature 3 on Diagrams 2 3 and 4 on any of the applicator heads indicates that not enough energy is getting from the battery to the diodes In this case it should be gradually warmed up before attempted use If the light does not dim after running the unit 2 3 minutes it should be returned to the nearest service centre Back to top 10 Testing for Output For Safety reasons you are cautioned not to test laser output by pointing the aperture at your eyes Superfine When the Superfine applicator head is operational the output of the laser head may be directed to the TEST see Diagram 1 Feature 5 area of the control unit If the laser applicator is emitting visible laser radiation the Laser Test Indicator Lamp 6 will illuminate Wide Angle When using the Wide Angle Head hold the applicator at arms length and at an angle away from direct viewing The 7 diodes will be visible indic
7. ating laser output Charging The Centurion Laser Shower contains either Ni Cad or Ni MH rechargeable batteries The system is fully charged when it leaves the factory and is received by you Under normal conditions you should be able to run the unit for 40 hours if only the Fine Point applicator is used and up to 10 hours if only the Wide Head Applicator is used A combination use of both heads will typically give you about 25 to 30 hours of use between charging The unit should not be charged until the BATT LOW light Diagram 1 Feature 7 is illuminated Frequent charging of the battery before full discharge may reduce the life of the battery pack or damage its ability to receive a full charge The battery pack has been custom designed for this unit and if these directions are followed is capable of being charged up to 1 000 times during its life Back to top 11 The following procedure should be used to charge the battery referring to Diagram 1 1 Charge only when BATT LOW light 7 illuminates on the generator faceplate 2 Charge with the key removed from the unit Do not use the unit while charging Using the unit while charging does not allow the battery to charge This may cause premature failure of the battery by causing the battery to discharge below a recoverable level 3 Plug the charger unit into the Insulated Charger Jack 9 on the generator faceplate and then plug the charger unit into the wall
8. consume extra energy provided by laser light to increase collagen production Wounds are repaired or closed over rapidly and less scar tissue is formed with the correct application of laser light 3 Beneficial Effect On Nerve Cells and the Production of B Endorphins Laser light increases the activity of the ATP dependent NA K pump thereby increasing the difference between resting potential and firing threshold across the cellular membrane This action decreases nerve ending sensitivity encouraging the blocking of pain sensation transmission to the brain Additionally painkilling chemicals naturally produced by the body such as endorphins and enkphelins respond positively to laser light exposure 4 Formation of New Capillaries and Increased Blood Flow Laser light increases blood flow in the treatment area and will significantly increase the formation of new capillaries in damaged tissue The formation of new capillaries speeds up the healing process closing wounds quickly and reducing scar tissue 5 Lymphatic System Activity and Reduction in Edema While increasing blood flow will help to remove water from swollen tissue the dirty protein waste requires additional support to drain from the damaged site Laser light is capable of doubling the size of the lymphatic ducts in the area of exposure and rapidly removing the protein waste contributing to swelling Laser light is further capable of reducing duct leakage in the l
9. eatment Applicator with Acupuncture Point Finder Diagram 4 Superfine Treatment Applicator with Acupuncture Point Finder 8 amp H 3 F O7 ft 1 On Off Switch 5 Auto Manual Switch 2 Emission Indicator 6 Laser Information Label 3 Service Indicator 7 Visible Laser Radiation Warning Label 4 Conductance Setting Switch 8 Aperture Diagram 5 Dispersive Strap 1 Acupuncture Applicator Head Connector 2 To Applicator 3 To Dispersive Strap 4 Male Connector 5 Female Connector Restraint Assembly The Acupuncture Point Finder operates in manual mode the same as the Superfine head applicator see previous section In automatic mode this unit will find acupuncture points and automatically turn itself on to deliver the treatment to the point This section specifically discusses the use of the system in automatic mode In either mode please ensure that the laser aperture is pointed away from your eyes and the eyes of the animal under treatment Referring to Diagram 5 connect the Dispersive Strap to an area where it can contact skin such as around the base of your horse s tail and secured with leading edge through the Restraint Assembly 5 as shown Ensure that the Male Connector 4 is completely secured in the Female Connector 5 When working with the Acupuncture Point Finder allow the applicator to touch and maintain contact with the skin with slight pressure applied Back to top 9 Point Locati
10. echargeable battery pack with 15V 600 mA charger unit Note check local mains supply is equivalent to charge rated input requirement 120V or 230V Swept frequency range 20 Hz 20 000 Hz Laser Class HIB Classification Laser Diode 785nm Wavelength Back to top 13 Maximum Peak Superfine Applicator 9 6mW Radiant Power Ultra Wide Applicator 25mW Treatment Default setting 15 minutes Duration User selectable 1 60 minutes Optimum Indoors room temperature 10C to 30C 30 75 relative Operating humidity Conditions Warranty 1 year parts and labour for electronics systems including the battery pack Optional warranty extension available The warranty is unconditional and will cover any and all problems Contact Information Sales and Service Canada Elec Western Medical Devices Ltd 1015 Matheson Blvd E 8 Mississauga Ontario Canada L4W 3A4 PH 905 238 4860 FAX 905 238 9140 Toll Free 1 800 387 8326 United States Centurion Systems USA Inc 105 Campus Plaza Drive Edison New Jersey 08837 PH 732 417 0050 FAX 905 238 9140 Toll Free 1 800 387 8326 Worldwide Email info centurionsystems com Website www centurionsystems com Elec Western Medical Devices Ltd Bay 2 Calgary Alberta Canada T1Y 527 PH FAX Toll Free 1 800 387 8326 Back to top 14
11. g period will automatically be selected on the digital display screen 2 You may choose more or less time from 1 to 60 minutes by pressing the or buttons below the display 4 To start the treatment proceed to the Operating Instructions for the chosen applicator Ultra Wide Superfine or Superfine with Acupuncture Point Finder NOTE To operate effectively the applicator should touch the skin unless treating an open wound or cut in which case the applicator should be held approximately 0 5 cm 1 4 away from the surface of the skin When operating the Acupuncture Point Finder the applicator should touch and maintain contact with the skin with slight pressure applied 0434 WARNING Avoid direct exposure of the beam to the eyes Ensure that the operator is wearing the safety glasses supplied with the system prior to energizing the system Failure to avoid direct exposure of the beam to the eyes could result in serious irreparable damage to the eyes including permanent blindness Ultra Wide Treatment Applicator Diagram 2 Ultra Wide Treatment Applicator 1 On Off Switch 4 Laser Information Label 2 Emission Indicator 5 Visible Laser Radiation Warning Label 3 Service Indicator 6 Aperture Back to top Please ensure that the laser aperture is pointed away from your eyes and the eyes of the animals under treatment Referring to Diagram 2 press the ON OFF button 1 A yellow light will illuminate 2
12. ld allow full laser penetration The Acupuncture Point Finder is an optional purchase This applicator may be purchased to compliment your system and is discussed in this manual Back to top 4 0434 Laser Information Visible Laser Radiation Warning Symbol FOR VETERINARY USE ONLY Usage Restriction VISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM VISIBLE LASER DIODE 9 4mW max 785nm CLASS IIIB LASER PRODUCT Laser Radiation Danger I iil AVOID EXPOSURE Visible Laser Radiation is emitted from this Aperture Visible Laser Radiation Warning Label Visible Laser Radiation Visible Laser Radiation Warning Label Centurion 1 800 387 8326 Sales amp Service WARNING Avoid direct exposure of the beams to the eyes Ensure that the operator is wearing the safety glasses supplied with the system prior to energizing the system Failure to avoid direct exposure of the beam to the eyes could result in serious irreparable damage to the eyes including permanent blindness Information amp Warning Labels Found on Product lt AVOID EXPOSURE a Sales amp Service Compliance Certification This Laser Product Complies with Federal Standards 21 CFR 1040 10 and 1040 11 of the National Center for Devices and Radiological Health at the Date of Manufacture CDRH Laser Compliance Back to top 5 Logic Generator Unit Diagram 1 Logic Generator
13. on with the Point Finder Acupuncture points are located with the point finder as zones having an increased skin conductivity a reduced electric resistance of the skin when compared to immediately adjacent areas of skin Procedure 1 Referring to Diagram 4 select AUTO with the Auto Manual Switch 5 A first reading is taken by placing the tip of the probe Aperture 8 to an area of the skin away from known acupuncture points and depressing the Conductance Setting Switch 4 for 3 seconds 2 Move the point finder probe towards the area where the point is assumed to be When you hit an area where there is less electrical resistance the yellow light 2 will illuminate and the probe will emit a buzzing sound indicating that treatment has begun Take a second reading of the electronic response of the new skin area by depressing the Conductance Setting Switch for 3 seconds 3 Move the point finder towards or within the region of the second reading When the electrical skin resistance lowers again you will get a signal If the skin resistance does not fall again you have found the center of the acupuncture point It is not always necessary to recalibrate the probe by following the steps 1 3 as above when moving from one treatment area to another Please Note A signal or switching on of the laser will occur when the current conductivity value is higher than the stored value This does not necessarily mean that you have found
14. outlet The Recharge light 8 will illuminate to indicate the correct connection has been made 4 Recharge for up to 10 hours The Recharge light will turn off automatically to indicate that the battery is fully charged Built in safety circuits preventing overcharging allow the charger to be left on overnight Unplug the charger before using 5 The battery may develop a memory effect from frequent charging prior to full discharge You will notice a drop in the capacity of the battery power causing fewer hours available from recharge In this case cycle the battery through 3 full charge and discharge cycles charge until the Recharge light turns off and discharge through use until the BATT LOW light illuminates X3 This will normally restore full storage capacity to the battery Care amp Cleaning Taking care of your Centurion Laser Shower system will help prolong its useful life When not in use store the unit in its supplied carrying bag The carrying bag is divided into two sections the control unit and charger should be stored in one section and the treatment applicators should be stored in the other section to avoid damaging the treatment heads Do not store with key inserted or applicators plugged into the unit Do not leave the unit out where it can be exposed to excessive dust or moisture Ensure that the storage area is between the temperature range of OC 32F and 45C 115F Do not store the unit in
15. ymphatic system thereby decreasing the likelihood of the same problem reoccurring in the same area Back to top 3 Centurion Laser Shower Equipment Your Centurion Laser Shower system consists of 1 Carrying Bag 1 Logic Generator Unit 1 Ultra Wide Head 1 Superfine Head or Superfine Head with Acupuncture Point Finder 1 Recharging Unit 1 User Manual 1 Pair of Safety Glasses General Safety Notes While operating the laser applicators care should be taken not to directly expose your eyes or the eyes of the animal under treatment to the laser radiation The sole source of laser radiation comes from the aperture at the treatment point of the applicators and should always be pointed away from the eyes at all times To avoid stray exposure ensure that the laser is off when treatment ends by visually confirming that the emission indicator lamps located by the ON OFF switch are off before you lift the applicator away from the treatment area Avoid the use of the laser system in the presence of mirrors or other highly reflective surfaces that are within 1 meter of the laser aperture Do not expose the laser system to direct solar radiation This product is not suitable for use in potential explosive areas The laser will not be effective when used over areas that have recently been treated with photosensitive chemicals such as cortisone furacin or iodine Scrubbing the treated area over a period of 5 10 days shou
Download Pdf Manuals