Home

water line - Crem International

image

Contents

1. Connect the hose from the carbon dioxide tube to the cooling unit s elbow connection See 1 Carbonated water Mount the water filter with regulator C and connect the hose from the water filter to the chiller unit s elbow connection See 2 cold water Connect the 1 2 hose to the water filter and then to the mains water supply D The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection Water IN 9 Insert the power plug in an earthed wall socket Water filter 10 Flush out approximately 2 5 litres chilled water and then approximately 2 5 litres carbonated water with regulator Wie ae f g before the machine is taken into use When installing hoses that go straight down two holes need to be drilled for the incoming hoses See fig A 5 Replacing water cleaning filter WATER LINE To make sure a high quality on drinks replace water cleaning filter every 6 months Replacing water cleaning filter Can changes under water pressure 1 Loosen filter by turn it 1 4 lap See fig 1 OPEN 2 Assemble the new filter by turn it 1 4 lap See fig 1 CLOSE water filter Filter from below Only use Coffee Queen original water cleaning filter Article no 1505344 IMPORTANT Now push the button for cold water Push until water is coming out in a regularly flow 6 Cleani
2. E WORKING WITH THE CONNECTIONS Hold the connection and press the hose into the connection s body as far as possible Disconnecting the John Guest connection Push the grey ring towards the connection and pull out the hose gt _ pP N If the water hoses need to be cut make a straight cut to prevent leakage 4 Installation Queen Aqua WATER LINE The installation shall be performed by an authorised installer Queen Aqua installation Install the machine using the water hoses and gas dome supplied 4 Undo the service hatch A 5 Mount the gas dome B on the carbon dioxide bottle and then fit the nipple supplied on the gas dome Connect the carbon dioxide bottle C to the chiller unit See 1 Carbonated water 6 Connect the hose from the water filter D to the chiller unit See 2 Cold water 7 Connect the 2 hose supplied to the machine E and then to the mains water supply The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection 12 water filter with regulator Connected to the carbon lt dioxide bottle Water IN 8 Insertthe plug in an earthed 230 V 10 A wall socket Flush out approximately 2 5 litres chilled water and then approximately 2 5 litres carbonated water before the machine is taken into use 4 Installation Queen A
3. User manual COFFEE QUEEN QUEEN AQUA Table Top QUEEN AQUA Floor model Serves chilled water and chilled carbonated water p 1m p E EZ m i _ 7 Your retailer U_EN Rev 090914 1 Contents WATER LINE Contents Notes for the user Using the machine Queen Aqua Installation Installation Queen Aqua table top Care replacing a water filter Cleaning the machine 1 2 3 4 4 5 6 7 Important 2 Notes for the user WATER LINE Thank you for choosing a Queen Aqua water dispenser we hope you will enjoy the benefits of using it Read through the manual carefully before you use the automatic water dispenser for the first time This manual contains important instructions for correct and safe usage of the water dispenser Always keep the manual in a place that is accessible for the user All you need to do is connect Queen Aqua to the water supply There is a free standing floor model as well as one that is integral on a work surface The water is chilled to the perfect temperature You can choose whether you want chilled water or carbonated water You can also choose whether you want water in a glass jug or bottle Product identification Queen Aqua Queen Aqua table top Height 1355 470 Width 310 210 Depth 330 330 Electrical connection 230 V 10 A 230 V 10 A Cold water connection 1 2 1 2 Refrigerant HFC 134A HFC 134A Cooling capacity 17 litres per h
4. ce or be subjected to direct sunlight The system is designed for use in an ambient temperature of no lower than 6 C and no higher than 28 C The system must not be used or placed in an ambient temperature that is lower than 0 C ELECTRICAL CONNECTION Connect the system to 220 240 V 50 Hz and 10 A The contact for electrical installation shall comply with the current CSN regulations EN and ISO standards If the cable is damaged it must be replaced by a qualified person This is to prevent an accident CONNECTION AND SERVICE The condenser shall be cleaned every 6 months in connection with water filter replacement Use compressed air when cleaning Carry out cleaning only once the power supply is disconnected from the chiller All installation work must be done by a qualified person WATER LINE COFFEE QUEEN ORIGINAL FOR SERVICE please contact Your retailer CREM International AB Box 960 671 29 ARVIKA Sweden Tel 46 0 570 477 00 Fax 46 0 570 47719 E mail info se creminternational com www creminternational com Art nr Art no 1730009
5. ng Daily cleaning WATER LINE Daily cleaning or when needed Outside cleaning use asoft rag and liquid cleaning agent to prevent scratches 3NI MSIVAA Empty and clean drip tray and drip tray insert daily 7 Important WATER LINE Important Do not do anything to the water dispenser Inappropriate action can lead to personal injury and faults The water dispenser should stand on a level surface to work satisfactorily The water dispenser must be placed on a waterproof surface so that any water leakage is visible Make sure that kinks are not formed in the connection hose during installation or when the water dispenser is pushed into place The machine s supply and drain connection shall be checked regularly Check that no leakage has occurred in connection with installation The water connection always presents a risk of leakage irrespective of safety equipment The water dispenser must be completely drained of water if it is going to be stored for a long time Turn off the water tap if the machine is not going to be used for a long time Disconnect the machine from the electricity supply before doing any work on it This can be done by pulling out the plug from the wall socket CHILLER SYSTEM INSTALLATION AND LOCATION The system is designed for use in standard environments according to CCN standard 33 2000 3 and is included in climate class N It must not be located close to a heat sour
6. our 17 litres per hour Power Single phase 293 W Single phase 293 W Automatic water replenishment Yes Yes Chilled water Yes Yes Carbonated water Yes Yes Gas dome nipple supplied supplied Water filter regulator Integral supplied Carbon dioxide bottle No You can purchase a height 580 x width 185 height 580 x width 185 carbon dioxide bottle from you local gas distributor 3 Using the machine WATER LINE ai Outlet carbonated water Outlet cold water Outlet for chilled drinks Queen Aqua has two outlets for chilled drinks Hold a glass below the outlet for the required drink Press one of the buttons Water will continue to run as long as you keep the button pressed 4 Installation Queen Aqua WATER LINE The installation shall be performed by an authorised installer Queen Aqua Installation 1 Place the machine on a level and waterproof surface 2 Mountthe machine on the floor cabinet and screw in place using the screws supplied Use a spirit level where necessary and adjust with the adjustable feet Make sure that there is free movement of air behind the machine Min 10 cm IMPORTANT The machine must be disconnected from the mains when work is done on it Pull the power supply cable out of the wall socket It is the end customer s user s responsibility to arrange the water connection to the machine according to the manufacturer s instructions NOT
7. qua Table Top WATER LINE The installation shall be performed by an authorised installer Queen Aqua Table Top Installation 1 2 Place the machine on a level and waterproof surface Install the machine using the water filter regulator elbow connections water hoses and gas dome supplied Use a spirit level where necessary and adjust with the adjustable feet Make sure that there is free movement of air behind the machine Min 10 cm IMPORTANT The machine must be disconnected from the mains when work is done on it Pull the power supply cable out of the wall socket It is the end customer s user s responsibility to arrange the water connection to the machine according to the manufacturer s instructions NOTE WORKING WITH THE CONNECTIONS Hold the connection and press the hose into the connection s body as far as possible Disconnecting the John Guest connection Push the grey ring towards the connection and pull out the gt n E If the water hoses need to be cut make a straight cut to hose prevent leakage 4 Installation Queen Aqua Table Top WATER LINE The installation shall be performed by an authorised installer Queen Aqua Table Top Installation 4 Mount the gas dome A on the carbon dioxide bottle B and then fit the nipple supplied for the water hose on the gas dome Mount using the elbow connections supplied under the chiller unit 1 and 2