Home

Oblica Pax Focus - Pivot Stove & Heating

image

Contents

1. 013 1999 to determine if appliance is excluded from full testing to this standard 09 06 2010 The maximum carbon dioxide output by the appliance during the high burn rate prescribed in AS NZS 4013 1999 was 3 79 This appliance meets the requirements of AS NZS 4013 1999 section 1 2 3 0 and is classified as an excluded appliance PAGE 13
2. 20 4 2 Do not burn Trash e Painted plastic Coated or preservative treated wood e Waste or black coal Inflammable liquids Fire gels e Moist wood with a residual humidity content of more than 20 this may cause soothing of the chimney IMPORTANT e Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee The maximum load capacity for the PaxFocus 15 20kg of wood Burning only seasoned hardwood helps to protect the environment and lower emissions For details of a wood supplier in your area please call our office on 03 9416 0400 or email info doblica com au e Do not use flammable liquids or aerosols to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of some types of preservative treated woods as a fuel can be hazardous OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 12 9 TESTING TEST REPORT ATL17 10 TESTING LABORATORY MANUFACTURER MODEL WORK REQUESTED TEST DATES RESULTS CONCLUSION OBLICA PAXFOCUS INSTALLATION AND USER MANUAL AHHA Testing Laboratory 6 26 Stirling st Thebarton SA 9031 08 8351 8056 Focus Atelier Dominique Imbert PaxFocus open style fireplace Extended to PaxFocus by Vipac Laboratory Measure C02 levels as outlined in AS NZS 4
3. PAXFOCUS INSTALLATION AND USER MANUAL 1 TECHNICAL DATA 2 PRE INSTALLATION 3 INSTALLATION 4 OPERATION 0 TESTING Keep for future use OBLICA 200 Argyle St Fitzroy VIC 3065 03 9416 0400 e 1 TECHNICAL DATA WEIGHT AND DIMENSIONS Firebox diameter W950mm x 650 Firebox weight 66Kg Flue diameter 219mm Flue weight 16Kg meter External flue kit Triple skin 200 250 300mm Nominal thermal output kW Efficiency 46 1 o PAXFOCUS ATTACHED TO NON COMBUSTABLE WALL 0950 mm OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 2 2 PRE INSTALLATION Congratulations on your purchase of the PaxFocus This appliance should be installed and checked by a qualified professional Ensure you have read the operation guidelines thoroughly prior to first use For any questions or concerns please contact Oblica on 03 9416 0400 The installation process is outlined below Determine position of firebox and flue carefully observing the clearances described within this section Install the suspension bracket Install the external flue Install the internal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation If such action is necessary consult the manufacturer in the f
4. ameters 2 Ensure the triple skin flue is installed as per Australian standards see diagrams below PITCHED ROOF INSTALLATION The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 8 meters from any higher section of roof oe ra FLAT ROOF INSTALLATION LESS THAN 5 PITCH The top of the flue must be 1200mm above the roofline Alternatively there must be a minimum distance of 8 meters from any higher section of roof vil v OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 7 a 3 INSTALLATION mastic r fractaire refractory mastic mastice refrattario 185mm lt X lt 195mm feuerfester Dichtungskitt OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 8 3 INSTALLATION mastic r fractaire refractory mastic mastice refrattario feuerfester Dichtungskitt air ambiant ambiant air aria ambiante Raumluft Needs more ventilation at rear of heater OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 9 3 INSTALLATION 3 4 Protecting the floor Floor protector MUST EXTEND 300mm in front of fire and 200mm on sides f installed directly on combustible material the floor protector must be made of a minimum 6mm thick cement sheet Non combustible finishes can be applied to the floor protector tiles steel sheet light concrete etc f the combustible floor is installed o
5. ding Code For information on heat shielding please contact our office on 03 9416 0400 or email infodoblica com au EM 935 9009 3 INSTALLATION 3 1 Installing the suspension bracket You must leave 25mm clearance gap between the flue and the ceiling This gap will be covered by the ceiling Flange 25mm minimum clearance from the triple skin flue to any combustible material within the roof space 40mm minimum overlap of the stainless steel 8 flue into the connector TYPICAL FLAT ROOF INSTALLATION CHINAMAN HAT Anti Down Draft device TRIPLE SKIN FLUE 200 X 250 X 300 8 x 10 x 12 PLASTER CEILING MINIMUM GAP 25mm lt CEILING FLANGE 150mm CONNECTOR LOWER FLUE 219mm OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 5 3 INSTALLATION PITCHED ROOF INSTALLATION CUSTOM MADE FLANGE CHINAMAN HAT Anti Down Draft device 4 SKIN FLUE 200 X 250 X 300 8 x 10 x 12 RUBBER FLASHING PLASTER CEILING MINIMUM GAP 25mm CEILING FLANGE CONNECTOR LOWER FLUE 219mm OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 6 3 INSTALLATION 3 2 Installing the external flue 1 Place the connection piece inside the suspension bracket This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different di
6. irst instance The appliance and flue system must be installed in accordance with AS NZS 2918 and the relevant building code or codes Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS NZS 4013 Once the flue has been installed and approved by a professional installer the flue must not be modified in any way OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 3 2 PRE INSTALLATION MINIMUM CLEARANCE INTERNAL 2 1 Clearance from non combustible surfaces eg masonry There is no minimum clearance required from fully non combustible surfaces Non Combustible Masonry Wall 2 2 Clearance from glass 390mm minimum clearance is required from normal non combustible glass 150mm minimum clearance is required from toughened glass Non Combustible sse O IMPORTANT Frames must also be considered Timber window frames must be treated as combustible surfaces see 2 3 Aluminium frames can be treated as non combustible surfaces see 2 2 OBLICA PAXFOCUS INSTALLATION AND USER MANUAL 2 3 Clearance from combustible surfaces eg timber joist amp plasterboard 700mm minimum clearance 15 required on the sides Non Combustible Masonry Wall Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Buil
7. n concrete you can replace the combustible material with non combustible material laid directly onto the concrete FLOOR PROTECTOR LAID ON TIMBER FLOOR lt i Combustible 200mm Insulative board 6mm floor eg timber combustible finish FLOOR PROTECTOR LAID ON JOIST Insulative board 6mm combustible finish Combustible 200mm floor eg timber sech OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 10 3 INSTALLATION FLOOR PROTECTOR LAID ON CONCRETE C_D nbustible 200mm ir eg timber 2 Non combustible finish eg tiles HHH R WHERE B HHHH EAE CR R Q eee DEE ae eae E FE Concrete TOP VIEW Ge IMPORTANT IREB0X A Cement sheet section must be ventilated Opening on both sides Floor protector non combustible finish Combustible floor eg timber OBLICA PAXFOCUS INSTALLATION AND USER MANUAL PAGE 11 4 OPERATION 4 1 What you should burn e Untreated air dried hardwood Split logs with a humidity content of less than