Home
        turbotwist-instructions
         Contents
1.          together when screwing the threaded         TANK back into place   PLACE ON BRACKET    4  Attaching the hose lock nuts         Snap the main body into the bracket indicated                         by a    click     Snap the other bracket with the    Position the hose lock nuts on the   Use flexible tubing to connect the sterilizer to the water  suction cup in the same way  hose barb inlet and outlet  supply  Turn the hose lock nut counter clockwise to tighten  flexible tubing onto the hose barb  Hose lock nuts require  HOSE LOCK NUT only hand tightening       Note  Do not use  O ring when larger  SNAP IN   D      hose barbs                   being used    FLEXIBLE  TUBING       Hose barb adapter installation     al                       Place the O ring on   Hand tighten the hose    Use flexible tubing to connect the sterilizer  hose barb inlet outlet  barb adapter onto the to the water supply  Turn the hose lock nut  Turbo Twist  counter clockwise to tighten flexible tubing  onto the hose barb   SAATIN een O RING HOSE BARB ADAPTER O RING     For horizontal positioning  take the suction         out and snap the main body into the  brackets until it locks with a    click       gt      gt  D     FLEXIBLE  TUBING  Note  Water will leak if the O ring is not in place  AMARE HOSE  LOCK NUT  2  UVC Lamp installation 5  Installing the Turbo Twist  THREADED CAP UVC LAMP            Remove threaded         install UVC    Hang the unit using the o Horizontal Positioning  lamp in
2.    TURBO TWIST     UV STERILIZER    12 Month Limited Warranty    WHAT THE WARRANTY COVERS     Central Aquatics  Company  warrants this product  see Exclusions below  to the original purchaser  against defective material and workmanship that occurs during normal use for 12 months from the  date of original purchase  Company will  at Company   s option  either repair or replace product or part  without charge  but no cash refunds will be made      EXCLUSIONS     1  Damage resulting from accident  misuse  abuse  lack of reasonable care  subjecting the product to  any but the specified electrical service  other than normal and ordinary use of the product  subjecting  the product to abnormal working conditions or any other failure not resulting from defects in materials  or workmanship     2  Damage resulting from modification  tampering with or attempted repair by anyone other than  the Company     3  Transfer of product to someone other than the original consumer purchaser     4  UVC lamp is not covered under warranty     WHAT YOU MUST DO TO ENFORCE WARRANTY     1  Contact the Company by mail or telephone to obtain support under warranty   Central Aquatics  5401 West Oakwood Park Drive  Franklin  WI 53132   E mail  info central aquatics com  Tel  800 255 4527  Fax  414 421 3530    2  Deliver  mail or ship the product  together with a copy of the original bill of sale  to   Central Aquatics  5401 West Oakwood Park Drive  Franklin  WI 53132  Attn  Tech Dept     You must pay any po
3. BALLAST    TURBO TWIST  BRACKET    y    TANK  BRACKET    SUCTION  CUP  HOSE LOCK NUT    HOSE BARB  ADAPTER    A  OSE     H  BARB INLET     The Coralife Turbo Twist Ultraviolet Sterilizers are easy to set up and operate   Please read all instructions in their entirety before installation     To accommodate your new sterilizer  you will need a power head  pump  or canister filter  with an appropriate flow rate for the size of your UV Sterilizer to ensure adequate ultraviolet  exposure while treating the entire volume of aquarium water with appropriate frequency     INSTRUCTIONS    SAFELOCK    QUARTZ  HOUSING    1  Set up and positioning    Adjusting the hose barb inlet and outlet    The hose barbs can be positioned in four different  locations to facilitate connections to other applications     QUARTZ SLEEVE      Lift the red safelock and unlock        the quartz housing   Picture 1     SAFELOCK   PICTURE 1     QUARTZ HOUSING          O RING GASKET MAIN BODY                Carefully twist the quartz housing    and the main body opposite of each  other   Picture 2      PICTURE 2   MAIN BODY    QUARTZ HOUSING          The quartz housing can now be  rotated 360     Picture 3     s i       SPECIFICATIONS    Article    Turbo Twist 3x    Turbo Twist 6x    Turbo Twist 12x       UVC Lamp    9 watt    18 watt    56 watt       Rated Voltage        120         120         120        Rated Cycle    Rated Power          2  10 2 watt          2  19 watt          2  58 watt       Irradiation 
4. er water flow has been established  tilt the unit and let    the air bubbles inside the tubing and the main body escape  Examine the unit and check for any leaks        Slide the quartz sleeve out of the                                                                ee main body   Picture 3   8  Power up Turbo Twist  PICTURE 3   QUARTZ SLEEVE   Connect the Turbo Twist to the power supply  Verify that the UVC  lamp is working properly  indicated by the light blue glow emitted    Wipe the quartz sleeve using a soft     Once clean  reinstall the quartz sleeve  through the lamp on indicator  The light from the lamp on   damp cloth  Do not use household into the main body and push the red  indicator will not affect the skin or the eye  LAMP ON cleaners or abrasive scrubbers to safelock into the lock position    INDICATOR clean the quartz housing     CAUTION CAUTION    Never look directly at the unshielded lamp as ultraviolet Never look directly at the unshielded lamp as ultraviolet  radiation is harmful  radiation is harmful     Disconnect the UV Sterilizer from the power supply when Disconnect the UV Sterilizer from the power supply when  installing or performing maintenance  installing or performing maintenance     Never submerse the UV Sterilizer in water  Never submerse the UV Sterilizer in water              WARNING    Troubleshooting        The plug is not connected to   e Connect the plug to the  the power supply  power supply     UVC Lamp     UVC lamp base is loose      Pu
5. of UVC Radiation     9 580 uW cm     11 400 W cm     11 400 W cm        Wavelength of Radiation    255 7    253  MM    253  MM       Life of UVC Lamp    Aquarium Volume    Approx  8 000 hrs  Up to 125 gals    Approx  8 000 hrs  Up to 250 gals    Approx  8 000 hrs  Up to 500 gals       Flow Rate  gallons per hour     100 200 gph    200 400 gph    400 1200 gph       Size of O ring  mm     12 16  16 22    16 22  22 28    16 22  16 28       Cord Length       Approx  9 ft       Approx  9 ft          Approx  9 ft     cvalue   20mm distance from the UVC lamp     Adjust the orientation of the hose  barb and set the main body into  the quartz housing       Combine the main body with the  quartz housing and rotate  according to the arrowhead     close      Picture 4        Press in the red safelock and the  UV Sterilizer is now ready to install    Picture 5     MAIN                               BODY   PICTURE 3    PICTURE 4                                  J l  Jii SAME AS PICTURE   PICTURE 5              Bracket Installation    3  Reassembly             Adjust the tank bracket so that it hangs    Slide the Turbo Twist bracket onto the tank  on the outside of the aquarium  bracket  Make sure the Turbo Twist bracket is      securely fastened onto the tank bracket  Make sure that the flat O ring gasket is  RANGE OF THE CLAMP properly positioned inside the threaded  TURBO TWIST          i i it   O RING GASKET                              ai        Note  The plug and cord should be turned
6. sh the UVC lamp onto the  is not working socket until a    click    is heard         The lamp has expired  e Replace the UVC lamp     Please read instructions in their entirety  before using the UV Sterilizer              Cut off the power immediately  if water enters into the quartz  housing     Cut off the power and stop using  if the UV Sterilizer was submersed  or dampened by water               The hose lock nut is loose      Tighten the hose barb or the    Water leak hose lock nut   between the A   main body and   hose lock nuts           The O ring is not in place      Install the O ring        Cut off the power if there is a  burning or smoking smell        UVC LAMP REPLACEMENT    The UVC lamp has a useful life of about 12 months  To ensure  effective performance  replace the UVC lamp once per year     Never connect the sterilizer to the   power outlet while hands are wet   A        SEEN    Do not pull cord to disconnect  power supply                    Never look directly at the  unshielded lamp as the ultraviolet  radiation emitted from the lamp  can be harmful        How to replace the UVC lamp       Disconnect the sterilizer from the power supply   It is also necessary  to disconnect the power to the water pump         Though the Turbo Twist is water  resistant  it should never be  intentionally submersed in water   Always install the sterilizer          location where there is little likelihood  of flooding or water dripping onto the  UV Sterilizer     Always lea
7. stage  shipping charges  insurance costs and other expenses to return the product  to Central Aquatics  Franklin  WI  However  if the necessary repairs are covered by the warranty  Company  will pay the return shipping charges to any destination within the United States or Canada     LIMITATION OF IMPLIED WARRANTIES AND EXCLUSION OF CERTAIN DAMAGES     THE COMPANY DISCLAIMS LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES FOR  BREACH OF ANY EXPRESS OR IMPLIED WARRANTY  INCLUDING ANY IMPLIED WARRANTY OF  MERCHANTABILITY  WITH RESPECT TO THIS PRODUCT  THIS WRITING CONSTITUTES THE ENTIRE  AGREEMENT OF THE PARTIES WITH RESPECT TO THE SUBJECT MATTER HEREOF  NO WAIVER  OR AMENDMENT SHALL BE VALID UNLESS IN WRITING SIGNED BY THE COMPANY  Some states  do not allow the exclusion or limitation of consequential damages  so the above limitation or exclusion  may not apply to you        TURBO TWIST     UV STERILIZER    Instructions       Please read these instructions in their entirety  before attempting to use this product     EPA Estab  No  073048 CA 00    Coralife     A product of Central Aquatics    Division of Central Garden  amp  Pet    Franklin  WI 53132 800 255 4527   Coralife   is a registered trademark of Central Garden  amp  Pet     2009 Central Garden  amp  Pet       PARTS DIAGRAM    THREADED CAP    HOSE BARB  ADAPTER    FLAT O RING    UVC LAMP    QUARTZ HOUSING    OUTLET     HOSE LOCK NUT    x Water pump  not included     LAMP ON INDICATOR    O RING GASKET        E PLUG    
8. to socket until lamp    clicks    Turbo Twist bracket and    Attach Turbo Twist bracket with screws on  into place  suction cup on the outside aed             of the aquarium  Adjust the   tank bracket to secure the   Turbo Twist UV Sterilizer    AQUARIUM          MAINTENANCE    To ensure superior performance  the quartz sleeve  should be cleaned periodically     6  Water flow outlet connection          Connect the tubing  between the water flow    CANISTER  outlet and the hose barb FILTER        Cleaning the quartz sleeve  t is recommended that a          prefilter be used with the 1    Disconnect UV Sterilizer from    Turbo Twist to limit the  amount of debris entering HOSE BARB   a INLET  the sterilizer     outlet  turn off the pump and let  water drain from Turbo Twist        Warning     WATER FLOW  Never install a      2                 lt    Lift the        safelock and unlock  the quartz housing   Picture 1     SAFELOCK                            between the  main body and  the aquarium              HOSE BARB INLET  QUARTZ HOUSING                                                           Note  Make sure that the tubing is not carrying the weight WATER FLOW          f   of the Turbo Twist UV Sterilizer  Use the Turbo Twist brackets 2    Carefully twist the quartz housing H   d        to support the unit  and the main body opposite of   a each other   Picture 2      PICTURE 2    7  Start water flow MAIN BODY    SAFELOCK  Turn on water supply to the Turbo Twist  Once prop
9. ve a drip loop in the  power cord to prevent water from  running down the length   of the cord and  reaching the  power outlet       Remove the threaded cap to    Unplug the UVC lamp out of the main body  uncover the lamp socket  and allow to cool          Make sure that appropriately sized  hose lock nuts are positioned on  hose barbs before attempting to  connect tubing     The water temperature flowing  through the UV Sterilizer should  be below 105  F  40  C      UVC LAMP    e          Once cool  pull the UVC lamp out  of the socket  Be careful not to  touch the lamp as it may be hot            Make sure that the pins of the lamp plugs  into the socket indicated with a  click         Only a 120V  60 Hz  electrical  source should be used with the  Turbo Twist     Always disconnect the UV Sterilizer  from the power supply before  shutting down the flow of water   to prevent overheating        Reassemble the Turbo Twist     7             Coralife Turbo Twist    UV Sterilizer Flow Rates    Suggested Tubing Connections    UVC ae      uw sec cm   55 gp _   TM     Parasites Turbo Twist    3x                         gallon hour        UVC             uw sec cm   gp    a  Parasites Turbo Twist    6x                                           PUMP           gallon hour     UVC mat 295 i   uw sec cm   gp            Parasites Turbo Twist    12x    1060 1200 1340 1480 1620   gallon hour           
    
Download Pdf Manuals
 
 
    
Related Search
 turbotwist instructions 
    
Related Contents
digiXMAS Universal Submitter .NET Version 2.0.0  TRAV`LER® WINEGARD®  User Manual  Instalando o Scan Cool LAN  Blaupunkt KLN RCM RCM 126 User's Manual  GSEOS V5.2 User Manual  Samsung HW-J8500 Lietotāja rokasgrāmata  S8 Escape™ II  HP 10 Gigabit Ethernet Cards Installation Manual  DinoSpin Service Manual    Copyright © All rights reserved. 
   Failed to retrieve file