Home
        Air-O-Swiss 7135 Ultrasonic Humidifier User Manual
         Contents
1.    fan 4                   Water tank   S  Demineralization cartridge   ASI   Water tank cap  Brush  Water base       Control panel       Main body       Water level sensor       Membrane  lonic Silver Stick    ISS        Power plug       Air inlet    AAA    www sylvane com 1 800 934 9194  Setting up    Finding the ideal location for your unit    e Do not place the humidifier directly next to a heating  vent or on a floor with floor heating  The moisture of  the mist can damage the floor surface  6   see Safety  Instructions     e The unit should be placed in an elevated position  7    e g  on a table  chest  etc  at least 3 ft off the floor    e The mist outlet must not be pointed directly at plants   furniture  or other objects  13   Keep distance of at  least 20 inches  50cm     e Soak the demineralization cartridge in a water bath  24 hours before using it  14   The resin has to absorb  water to reach high performance  If it is soaked in the  tank  make sure to exchange the water and empty the  water from the base before using the humidifier    e On average the demineralization cartridge should be  replaced every 2     3 months depending on your water  hardness  Some areas may need to replace the cart   ridge sooner  some may last longer  The cartridge must  be exchanged at the latest after 6 months or the unit  does not reach its full performance anymore    See   Replacement of the demineralization cartridge      e Read the instructions under   Filling the Tank   for  ad
2.  a door  win   dow or air vent  This increases the air circulation     Q   A           Tank is leaking   Check if there are any hairline cracks  Dropped units or  water tanks that are cracked will not be covered under  the warranty  Please contact the retailer the unit was  purchased from in case your unit arrives damaged     Placing the face in the mist      It is not recommended that anybody places their face    in the mist  It is an electrical product and should not be  played with     No mist   unit is not working   empty indicator  keeps flashing      Fill up the water tank  Check if water is flowing through    the demineralization cartridge  attached to the water  tank cap   If the water tank is full but there is only little  water in the base it indicates that the water is now  flowing through the demineralization cartridge    Wait for 15 minutes to allow the mist to come out of  the unit    If the unit is not working and the empty light is not  flashing you might have set the desired humidity too  low and the current humidity level in the room is hig   her  That is why the unit switches off automatically    If the empty indicator keeps flashing and the tank is  full  the water is not flowing through the cartridge   Exchange the cartridge or the granules in the cartridge  after 2 3 months  in areas with hard water exchange  the cartridge after 1  2 months  However  the demi   neralization cartridge and or the granules must be  exchanged at the latest after 6 months or 
3.  of respiratory  system    Causes weariness  tiredness and poor concentration   Stresses household pets and house plants   Encourages the formation of dust and the electrostatic  charging of textiles made of synthetic fibers  carpets  and plastic flooring    Damages furnishings made of wood and parquet   Detunes musical instruments     General information   A comfortable atmosphere indoors is reached with a re   lative humidity level between 40 and 60   Your humidi   fier automatically controls the humidity level according  to desired setting  If the air is too dry  the humidifier will  automatically switch on  As soon as the desired humidity  level is reached  it will switch off        www sylvane com 1 800 934 9194  Unpacking    e Carefully remove the humidifier from the box  Place  your hands underneath the product to pull it out of the  box  10     e Warning  Do not take the unit out of the box by pulling  up on the tank handle   base may fall and will be da   maged  11        Warning  The mist outlet is packed in a red bag inside  the box insert  Make sure that you remove the mist  outlet from the packaging  12     e Remove the plastic bag from the humidifier    e Observe the information given on the rating plate about  the voltage    e Use the original packaging for storing the appliance if  you do not use the humidifier all year round                                         Description of the appliance       Mist outlet  rotating                     Evaporation chamber
4.  only one way  If the  plug does not fit fully in the outlet  reverse the plug  If it  still does not fit  contact a qualified electrician  DO NOT   attempt to defeat this safety feature    e A loose fit between the plug  receptacle  and the  AC outlet may cause overheating and a distortion  of the plug  Contact a qualified electrician to replace  loose or worn receptacles    e Do not sit  stand or place any heavy objects on the  appliance    e Do not submerge the main body in water or other  liquids    e Disconnect power supply before servicing    e Persons who are not familiar with the instructions  for use  as well as children and persons under the  influence of medication  alcohol  or drugs are not  permitted to operate the appliance  or are only per   mitted to operate it under supervision        e The use of water additives  such as ethereal essential  oils  fragrances  eucalyptus  water conditioners etc    damages the tank material and as a consequence  the whole unit  Any use of such additives will void the  manufacturer   s warranty    e Remark  Neither humans nor animals can hear the high  frequency vibrations     AAA          www sylvane com 1 800 934 9194                                                             Foreword  Congratulations on choosing the Ultrasonic AIR O SWISS  7135  Did you know that dry room air     Causes the membranes in your respiratory system to  dry out  and also causes chapped lips and stinging  eyes    Encourages infections and illnesses
5.  red bars are displayed  you have  selected the highest level of mist output  symbol H      E  Operation with water pre heating    warm mist   Button E is used for switching the pre heating on and off   symbol I lights up   As a result  the water is pre heated  to a temperature of 176   F  80   C  before entering the  nebulizer space  It takes approx  10 to 15 minutes for the  water in the base to warm up  The mist now leaves the  humidifier at a pleasant temperature of 104   F  40   C   The  advantage of this is that the room temperature does not  drop and  in addition  it significantly improves the water  quality maintenance     F  Automatic mode and Sleep mode   The automatic and sleep modes can be activated by pres   sing button F  By pressing the button once  the automatic  function is switched on  symbol J appears on the display    maintaining the optimum humidity subject to the tempera   ture  Control takes place by means of output quantity and  pre set target value  If the sleep function is switched on   the symbol K appears on the display   the target humidity  is 60   the operation time is automatically set at 8 hours   the heating is switched on  In addition  the output quantity is  also controlled subject to the difference between the target  value and the actual value    The Timer cannot be changed in either mode  If other but   tons are pressed  the unit will no longer be in auto or sleep  mode        L  Empty indicator   The water level is easy to see  thanks t
6. ailer or check our website www airoswiss net  for reorder information    The lonic Silver Stick   comes with a metallic clip which can  be removed for the placement in this product type     Lifecycle Indicator   Your appliance comes with a lifecycle indicator for changing  the lonic Silver Stick    To remind yourself of when you put  the ISS into operation  please cross the current month on  the stamp and write the current year on the line provided   28                        IONIC SILVER STICK  LIFECYCLE INDICATOR  AIR O SWISS    rf                   Replacement of the demineralization  cartridge    Always unplug the unit before removing the  AN water tank  Do not touch the water in the base    during operation     The water tank is equipped with a demineralization cart   ridge  This cartridge has to be replaced every 2     3 months   If the water is very hard  it may be necessary to replace the  cartridge earlier  White dust around the device is a sure sign  that the cartridge needs replacing  Please note white dust  is not harmful  If white residue still forms around the device  after a new cartridge has been inserted  please make sure  that the water you are using is untreated  If the water flows  through a decalcification system     such as an ion exchanger       sodium is added to remove calcium  in the building before    it    is used in the humidifier  salt can precipitate as white dust    around the device  The demineralization cartridge and or the  granules must be 
7. city  out of tune    musical instruments  increased levels of dust  dry air  causes dust to rise   damage to wooden objects  dry  out and eventually cracks appear   discomfort  sick   ness  and dries out nasal membranes   Over humidifying the air can cause mold and wallpaper  to peel     www sylvane com 1 800 934 9194    Q  Why do   need a humidifier when   can just open  my window    A  The moisture level within the outside air is not high  enough to humidify a room  The colder the air the less  moisture it is capable to hold  and the more the air is  heated up the percentage of relative humidity is lower   Relative humidity means the amount of water vapor in  the air  compared to the amount the air could hold if it  was totally saturated  The difference is higher between  outside and inside temperatures  more humidification  is needed because of the dry air in the room     Q  Where should   place my humidifier    A  The unit should be free standing and not close to a  wall  window  door  or thermal bridge so that air may  circulate around the unit     Ultrasonic Frequent Questions    Q  Why does it say open close on the demineralization  cartridge cap    A  Those directions are there in case you decide to use  the refill option to replace the granules  the purpose is  for how to open and close the cap  If you did open the  cap before placing it in the water tank  you will most  likely notice that there are granules in the water tank  and the base of the unit  Immediately tu
8. ding water in the humidifier  15 and 16     e Place the water tank onto the base    e Insert the plug into the socket and switch on the  appliance using the on off dial  19     e About 10 to 15 minutes after it is switched on the de   vice will reach its full output level    e Make sure that the cable is not pinched anywhere  9    Do not operate the humidifier if the cable is damaged                                  Filling the tank  Always unplug the unit before removing the  N water tank  Do not touch the water in the base  during operation     Do not operate the humidifier when the water tank is  empty  When the water reaches the minimum level  the unit  switches off the nebulizer function automatically  The red  light comes on indicating tank is empty     e Remove the water tank from the base and unscrew the  water tank cap  15   Caution  the mist outlet is loose   Make sure that no foreign objects are in the water  tank    Fill the tank with clean  cold water from the tap  16    Close the cap of the water tank securely  place the wa   ter tank onto the base  17   The water is now running  from the tank into the base    Do not pour water into the mist outlet of the appliance   18     Insert the plug into the socket and switch on the  appliance using the on off dial  19   The red empty  indicator light may stay illuminated for some seconds  until the base is filled with water  Then the green light  comes on     Use of additives   Water additives  ethereal essential oils  f
9. exchanged at the latest after 6 months or  the unit does not reach its full performance anymore     Option A  replace the resin    e Remove the water tank from the base and unscrew the  water tank cap  29   Caution  the mist outlet is loose   The demineralization cartridge is attached to the tank  cap  Unscrew the cartridge from the cap by turning it  counter clockwise  30   Important  do NOT dispose of  the water tank cap     e Open the cartridge  31    e Throw the content into the waste  Attention  Disposed    resin can make the floor slippery    32     Place the enclosed pink styrofoam piece in the center  of the cartridge  Do not push it to the bottom as it will  be difficult to remove afterwards  33     Pour the contents of one refill resin bag into the plastic  cup that is included with the refill resin packaging  34    Place the empty cartridge with the plug in the center  onto the plastic cup  35     Turn the plastic cup and cartridge over and shake until  all resin is in the cartridge  36      2    www sylvane com 1 800 934 9194    Remove the plastic cup and the pink styrofoam piece  from the cartridge  37  and retain for future use  the  refill resin consists of 3 refill bags   38     Close the cartridge  39     Soak the demineralization cartridge in a water bath  24 hours before using it  42   The resin has to absorb  water to reach high performance  If it is soaked in the  tank  make sure to exchange the water and empty the  water from the base before using the hu
10. l than external hygrometer    A  Not all hygrometers are calibrated the same  and most  are off by     5   Plus the humidity level is not the  same in the whole room  The air circulation is different  in every corner of the room  The unit should not be  placed near a heating vent or a radiator as the heat will  absorb all of the moisture     Q  Humidity level is not changing or does not reach  the desired humidity level    A  If the water tank needs refilling more than once per  day  the unit is working properly and the climatic con   dition in the room has an influence on the humidity   Reasons for low humidity level    e air circulation is very high  air is fully exchanged se   veral times per day     the humidifier needs to starts its  work from scratch    e insulation of home  see air circulation       open space with high ceilings  not only the footage of  the room counts but also the height      high rise buil   dings require more humidification       open windows     works similar to air circulation  if it is  very cold outside don   t open the window more than 2  times per day for 3 minutes    e big difference between outside temperature and inside  temperature     the colder the air the less moisture it  is capable to hold and the more the air is heated up  the lower is the percentage of relative humidity   the  amount of water vapor in the air  compared to the  amount the air could hold if it was totally saturated    e position of the unit   if it is placed close to
11. midifier   Screw the cartridge on the water tank cap  43    Screw the cartridge on the bottom side of the water  tank  put the tank on the main body  44      Placing granules in the center of the cartridge  allows them to escape in the unit or to clog the    unit  The unit will no longer operate properly and  the granules need to be cleaned out thoroughly     Option B  replace the whole cartridge    e Remove the water tank from the base and unscrew the  water tank cap  29   Caution  the mist outlet is loose   The demineralization cartridge is attached to the tank  cap  Unscrew the cartridge from the cap by turning it  counter clockwise  30   Important  do NOT dispose of  the water tank cap    Throw the whole cartridge into the waste  40    Unpack the new cartridge  41     Soak the demineralization cartridge in a water bath  24 hours before using it  42   The resin has to absorb  water to reach high performance  If it is soaked in   the tank  make sure to exchange the water and empty  the water from the base before using the humidifier   Screw the cartridge on the water tank cap  43   Close  tank cap well and place the tank on the main body   44                                                         www sylvane com 1 800 934 9194                                                                                  Storing the appliance for extended periods  Clean the appliance as described earlier and allow to dry  thoroughly  Preferably store the appliance in its original box   i
12. n a dry place away from high temperatures     Legal notice   The humidifier is CUL listed    Subject to technical change  The instructions for use are  protected by copyright O PLASTON AG     Accessories  Contact your local retailer or check our website www   airoswiss net for re order information     Customer Service    Customer Service  USA  1 800 336 0326  www airoswiss net    Trouble shooting    Problem Possible cause       www sylvane com 1 800 934 9194  Technical data                         Electrical voltage 120V   60 Hz  Power consumption up to 45 W    140W    Humidity output up to 3 5 gallons   24 h   Suitable for rooms up to 650 sq ft 60 m   Dimensions  LxWxH  15 x 8 7 x 13 8 in   38 x 22 x 35 cm  Weight  empty  7 7 lbs   3 5 kg  Accessories Demineralization cartridge    lonic Silver Stick           when used with pre heating to 176   F  80   C     What to do       Unit does not operate Power cable not plugged in    Plug in power cable       No water in the tank  Empty light red     Fill tank with water and wait 10 min        No mist output Unit needs cleaning    Descale the water base using EZCal       DMC exhausted    Replace cartridge or granules       DMC overfilled with granules    Take out 2 tablespoons of granules and throw  them away       Weak mist output    Water temperature too low    Set mist output to maximum  after 15 min   the humidifier will work properly again       Mineral deposits on membrane    Clean membrane using EZCal and brush       Unit run
13. ning intermittently  White dust around the humidifier       Demineralization cartridge exhausted    Replace demineralization cartridge or resin             General Humidifier Questions    Q   A     Why isn   t there enough moisture in my room    How often do you run the unit  If the unit is only run at  night  then during the day the moisture level will drop if  moisture is not constantly added to the air     Do you leave your door open or closed when the  unit is running       a  By leaving the door open  this allows moisture to    leave the room and go into other areas of the house   If you would like the moisture to stay within one  specific room you should consider closing the door  while the unit is running    b  Wood  leather  carpet  curtains  and other types of  fabric soak up a lot of moisture  thus not leaving en   ough moisture for the air  If the window is left open   then this allows moisture to escape the room  Ano   ther factor is a lot of times the unit is placed next to  a heating device  The idea is that the air blowing  into the room will quickly place moisture around the  room  Unfortunately  this concept does not work  because the hot air coming out of a vent will soak  up most of the moisture  and none of the air within  the room will receive any       How much moisture do   need in my room     Suggested humidity levels are between 40     60        What are the effects of too little or too much    humidity       Dry air can cause dry skin  static electri
14. o be replaced before using the unit    Exchange the demineralization cartridge after 1 2  months when you use very hard water  for softer water  after 2 3 months   No matter how hard your water   is  exchange the cartridge at the very latest after 6  months    Don   t use water from a pre installed water softener    or sodium instead of calcium will be emitted from the  unit  Use distilled water instead and remove the demi   neralization cartridge    For very hard water areas use only distilled water and  remove the demineralization cartridge    Use Reverse Osmosis water  R O water  instead of dis   tilled water and remove the demineralization cartridge     Cleaning light is flashing  model 7135 7142 7144   Switch off the unit and unplug it  Empty the water in  the base  Rinse the base with hot clean water  Do not  submerge the base  Visually inspect the base for dirt or  mineral build up  If soft water is used decalcifying the  unit every 4 weeks with EZ Cal is suggested  If hard  water is used the unit should be decalcified every 2  weeks  Do not forget to reset the clean light after reset   ting the unit     www sylvane com 1 800 934 9194    Q  Reset cleaning light  model 7135 7142 7144    A  The cleaning light does not automatically reset  Hold  down the power button  button A in instruction manual   until the light stops flashing  The light automatically  comes on approx  after 14 days of plugging in the unit     Q  The hygrometer on unit reads a different humidity  leve
15. o the transparent  water tank  The appliance also alerts you when the water  tank is empty  The empty indicator is illuminated  symbol L    Please read the chapter   Filling the tank   for more informa   tion  The symbol L may stay illuminated for some seconds  with a refilled tank until the base is filled with water     M  Cleaning indicator   If symbol M and   CLEAN   appear on the display  the appli   ance should be cleaned as recommended by the manufac   turer  This symbol comes on automatically every 2 weeks   depending on the level of use  The display can be reset by  holding down button A until the light disappears     AAA             www sylvane com 1 800 934 9194    Cleaning Maintenance EN  Always unplug the unit before removing the  water tank  Do not touch the water in the base    during operation               O      Caution   risk of electric shock and  damage of the product     e Switch off the appliance and unplug it from the socket  before cleaning it  20     e Clean the water tank and the base regularly  Use water  only  no detergents  21     e Use AIR O SWISS EZCal custom cleaning and desca   ling agent only to remove deposits from the membrane  regularly  22 and 23   There is a sample of EZCal in   cluded in the packaging of your humidifier  Instructions  for using are on the packet  Only use 1 packet for 32 oz  of water  Do not change the ratio  Do NOT run the unit  when using EZCal  This can cause damage to the pro   duct and voids the warranty  Thoroughl
16. r tank        lonic Silver Stick    water treatment  replacement  reminder     In each lonic Silver Stick    ISS  box and on all the new  products there is an ISS lifecycle indicator  Check the  box of the month when starting to use the ISS and  write the year on the line indicated  Exchange it after  12 months       What is EZ Cal      There is a sample packet of EZCal included in the  packaging of your humidifier  EZCal is used for cleaning  and descaling any of the AIR O SWISS products  and  Cleans mineral build up  EZCal is the only recommen        www sylvane com 1 800 934 9194    ded cleaning and descaling solution  Do NOT use any  other cleaning solutions since it can damage the pro   duct  Any use of cleaning solutions apart from EZCal  will void the warranty  Instructions for using are on the  packet  Only use 1 packet for 320z of water  Do not  change the ratio  It can also be used for any other hu   midifier brand  Do NOT run the unit when using EZCal   This can cause damage to the product and voids the  warranty  Thorougly rinse the base with potable water  and make sure no EZCal residues remain in the base   EZCal is available at selected retail stores     z          www sylvane com 1 800 934 9194    Please check our website www airoswiss net    for further information        CPLASTON    AIR 0 SWISS is a brand name  of PLASTON AG  Switzerland        
17. ragrances   eucalyptus  water conditioners  etc   must not be used   Even a small amount can cause cracks in the material  The  material isn   t made for the use of such additives  One drop  is enough to damage the tank and as a consequence the  unit  Any use of such additives will void the manufacturer   s  warranty        www sylvane com 1 800 934 9194                                                 Operation 7135       A  On   off dial   You can switch the unit on or off by pressing button A  This  button is also used to reset the cleaning indicator light  by  holding down      B  Hygrostat  setting the humidity level    By pressing button B you can set the desired humidity  level in    A relative humidity between 40  and 60   is recommended  The accuracy of measurement is     5    The unit will switch off when the moisture level exceeds the  desired setting  The device does not switch off if the dis   play is set to   Co    continuous operation   During selection  the target value is displayed  The display will automatically  show the current value after a few seconds     www sylvane com 1 800 934 9194  C  Timer    Using button C  the operation time can be set adjustable  between 1 and 9 hours  Symbol G shows the operating  period that has been set  1h 2h 3h 4h 5h 6h 7h 8h 9h    The display will automatically show the current value after  a few seconds     D  Mist output  regulating mist output   The mist output can be regulated by pressing button  D several times  If the
18. rn off the unit   and empty the water out of the base and the water  tank  Begin removing all granules from base and water  tank  Use brush to clean around membrane    Caution  Do not dispose of granules in sink  Used  granules must go in waste     Q  I just replaced my cartridge  and the contents and  water in the base has turned a blue green color    A  This sometimes occurs when the cartridge  or even  the granules  are replaced  This does not occur with all  replacement cartridges or granules  and is a reaction of  water content and the Ultrasonic vibrations  This is not  an indicator to replace the cartridge     Q   A        There is no fill line on the water tank  how far  may   fill it up    There is no fill line on the water tank  and it may be  filled all the way to the top        What is the purpose of the demineralization cart   ridge  DMC        The DMC removes minerals from the water to prevent    white dust  The contents of the cartridge need to be so   aked for 24 hrs prior to first using the unit so that they  may fully expand and remove minerals from the water   The contents of the DMC have a life of 2     3 months   The cartridge may need to be replaced more often  depending on water hardness and how often the unit  is used  An indication of when the DMC needs to be  changed can be white dust or reduced amount of mist  output     Is it ok to use distilled water with the unit       For best results with your ultrasonic humidifier use    distilled or reverse o
19. smosis water and remove the  demineralization cartridge       just replaced the contents of the cartridge and  now have granules everywhere       First  make sure there are no granules in the middle    of the cartridge  Placing granules in the middle of the  DMC allows them to escape in the unit  Immediately  turn off the unit  and empty the water out of the base  and the water tank  Begin removing all granules  from base and water tank  Use brush to clean around  membrane    Caution  Do not dispose of granules in sink  Used  granules must go in waste     The directions tell me not to place the unit directly  on the floor  why do I have to elevate the unit       The idea with this unit is to allow one to force humidity    into the air  Because of this  the carpeting or wood floor  surrounding the unit may become damp  If the unit is    z    placed at least 3 feet off the floor  the mist will have the  opportunity to evaporate before hitting the floor     Water does not go into the tank    In order to fill the tank  it must be turned upside down   The cartridge is placed on the water tank cap  Do not  pour water in the tube which is the mist outlet     White dust is emitted from the unit   White dust particles are minerals that are broken up in  tiny pieces by the ultrasonic process    Solve the problem    Soak the demineralization cartridge in a bowl of water  for a minimum of 24 hours  If the cartridge is soaked  in the water tank  the water in the tank and the base  needs t
20. the unit does  not reach its full performance anymore   If the granules are new  see the following instructions   Make sure the cartridge and or granules were soaked  for 24 hours  dry granules take even longer for water  to filter through the cartridge and into the base  Next   please remove 2 tablespoons of granules from the  cartridge  and throw them away  When there are too  many granules in the cartridge it does not allow water  to flow from the tank to the base     z      Water tank cap is too tight to unscrew     This could be a cause of the air pressure within the  water tank  Depress the spring on the bottom of the  water tank cap to release air from the water tank   Continue to do this until you are able to unscrew the  water tank cap       Unit is running intermittently      How long has it been since the contents of the cart   ridge were replaced  If 2 3 months have passed  it is  time to replace the contents of the cartridge  However  the demineralization cartridge and or the granules  must be exchanged at the latest after 6 months or the  unit does not reach its full performance anymore    If the contents of the cartridge were just replaced there  are probably too many granules in the cartridge  Re   move 2 tablespoons of granules from the cartridge     Accessories      Do I need to keep any parts before I replace the  demineralization cartridge      Yes  always keep the water tank cap  this is the piece  that attaches the demineralization cartridge to the  wate
21. urface can become damaged   We do not accept any liability for damages in the case  of incorrect placement of the unit    e The unit should be placed in an elevated position  7    e g  on a table  chest of drawers  etc    e Place appliance where it is not easily knocked over  8     e Always unplug when not in use    e Only operate the humidifier when it is completely  assembled    e ALWAYS unplug before removing filling emptying the  water tank  before cleaning maintaining  assembling   dismantling of individual parts and before moving the  appliance     e Do not touch the water in the base during operation  because of high frequency vibrations in the water    e Do not run power cords under carpets  and do not co   ver with throw rugs  Arrange cord so that it will not be  tripped over    e Never pull the plug from the outlet by the cable or with  wet hands    e Do not use the appliance where combustible gases or  vapors are present    e Do not expose the appliance to rain  or use near water   in a bathroom  laundry area or other damp location    e This unit must be used in its upright position    e Do not allow foreign objects to enter ventilation or  exhaust opening as this may cause electric shock or  damage to the appliance  Do not block air outlets or  intakes    e Do not pour water into the mist outlet of the appliance   e This appliance has a polarized plug  one blade is wider  than the other   To reduce risk of shock  this plug is  intended to fit in a polarized outlet
22. www sylvane com 1 800 934 9194    PLEASE READ AND SAVE AIPR O SWISSE    ALL INSTRUCTIONS  ADVANCED AIR TREATMENT SYSTEMS    AOS 7135       www sylvane com 1 800 934 9194             www sylvane com 1 800 934 9194       Instructions for use u             www sylvane com 1 800 934 9194    PLEASE READ AND SAVE ALL THESE INSTRUCTIONS     Important safety instructions  e Prior to using the appliance  read through the in   structions for complete use and retain in a safe place  for later reference    e WARNING     Only use the Ultrasonic indoors and within  the specified technical data  Improper use can be  hazardous for the health and lead to critical injury    e Connect the unit only to alternating current with  voltage according to the rating label    e Children cannot recognize the hazards associated    with the usage of electrical appliances  For this reason     always supervise children when they are near the  humidifier  image 1     e Never use the appliance if there is any damage to the  appliance or cable  2   after malfunction  after the  appliance has been dropped  3  or damaged in any  other way    e Repairs of electrical appliances are only to be made by  qualified service engineers  4   Improper repair work  can cause considerable danger to the user    e Place the humidifier on a dry  level surface  5     e Do not place the appliance directly on the floor or  next to a heating vent  6     e  f the mist comes in contact with the floor prior to  evaporating  the floor s
23. y rinse the base  with potable water after using EZCal and make sure no  EZCal residues remain in the base                                         140  F   60  C          EZCal from AIR O SWISS is the only recommen   ded cleaning and descaling solution  Do NOT use  any other cleaning solutions since it can damage    the product  Any use of cleaning solutions apart  from EZCal will void the warranty     e Make sure main body is never submerged in water   24     e The cleaning indicator still appears on the display after  cleaning  To reset it hold down the ON OFF button until  the clean light stops flashing    e Clean the inner parts with a soft cloth  Do not use any  solvents or aggressive cleaning agents to clean the  appliance  25     e Only use the brush to clean the membrane  This should  be done once a week  Only use the soft bristle portion  of the brush  26     e Change the water in the tank at least once a week if  water is standing for more than a week     www sylvane com 1 800 934 9194    Water quality maintenance   The lonic Silver Stick    27  keeps the water free of micro   bial growth  The anti microbial action of silver is used  The  lonic Silver Stick  ISS  releases silver ions in the water over  a long period of time  approx  one year   It s self regulating  and maintenance free  Look at picture 27 for the position of  the ISS in the base part of the unit  Do not touch the water in  the base during operation  Switch off the unit first  Contact  your local ret
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Projecta Descender RF Electrol  Les fiches descriptives des ZNIEFF Mode d`emploi    Sony IPT-DS2 Operating Instructions  VITRO Instrucciones de instalación y funcionamiento  REF/DIF 1 - University of Delaware  Untitled  ・本製品を末永く軸用頂くために、この説明書は大切に保管してください。    Copyright © All rights reserved. 
   Failed to retrieve file