Contents
1. 14 2 i SAFETY WARNING This product should be installed and serviced by a qualified technician electrician or electrical maintenance person familiar with its operation and the hazards involved Proper installation which includes wiring mounting in proper enclosure fusing or other overcurrent protection and grounding can reduce the chance of electric shocks fires or explosion in this product or products used with this product such as electric motors switches coils solenoids and or relays Eye protection must be worn and insulated adjustment tools must be used when working with control under power This product is constructed of materials plastics metals carbon silicon etc which may be a potential hazard Proper shielding grounding and filtering of this product can reduce the emission of radio frequency interference RFI which may adversely affect sensitive electronic equipment If information is required on this product contact our factory It is the responsibility of the equipment manufacturer and individual installer to supply this safety warning to the ultimate user of this product SW effective 11 92 This control contains electronic Start Stop and Inhibit circuits which can be used to start and stop the control However these circuits are never to be used as safety disconnects since they are not fail safe Use only the AC line for this purpos
2. 8 8 Parts List 15 FIGURES 1 Basic KBIC 5 2 Mechanical Specifications 7 3 Connection Diagrams 8 4 ACCEL Trimpot Adjustment 10 5a Master Slave Circuit 12 5b Dynamic Brake Circuit 13 5c Overload Protection 13 6 Schematic
3. the AC input voltage corresponds to the control voltage rating and the motor rating e g 90 130VDC motor on 115VAC and 180VDC motor on 230VAC 3 Follow the recommended supply wire sizes as per table 6 p 8 4 Follow the NEC and other electrical codes that apply CAUTION Separate branch protection must be provided on 240V circuits Do not fuse neutral or grounded conductors 5 Connect control in accordance to connection diagram See fig 3 p 8 6 When using a step down transformer 440 VAC to 220 VAC be sure the VA rating of the transformer is at least 3 times the VA rating of the motor 7 TABLE 6 Minimum Supply Wire Size Requirements Minimum Recommended Wire Size MAX MOTOR CURRENT DC AMPS MAX MOTOR HP 90V MAX MOTOR HP 180V MINIMUM WIRE SIZE AWG Cu only MAX 50 FOOT RUN MAX 100 FOOT RUN 6 0 5 1 16 14 12 1 2 14 12 16 1 5 3 12 12 FIG 3 CONNECTION DIAGRAM TABLE 7 Field Connections Shunt wound Motors Only Caution Shunt wound motors may be damaged if field remains energized without motor rotating for an extended period of time AC LINE VOLTAGE FIELD VOLTAGE VDC FIELD CONNECTION FIELD TYPE 115 100 F F Full Voltage 115 50 F L1 Half Voltage 230 200 F F Full Voltage 230 100 F L1 Half Voltage 8 WARNING If control is wired to a transformer do not switch the primary side of transformer to disconnect power or catas
4. Note Do not attempt to adjust the MAX speed above the rated motor RPM since unstable motor operation may occur For moderate changes in the MAX speed there will be a slight effect on the MIN speed setting when the MIN speed is set at zero There may be significant variation in the MIN speed setting if the MIN speed is at a higher than zero setting C Minimum Speed Adjustment If a higher than zero speed is desired readjust the minimum speed by turning the main speed potentiometer to zero setting full CCW position Then adjust the MIN speed trimpot to the desired setting 10 Note The MIN speed adjustment will affect the MAX speed setting Therefore it is necessary to readjust the MAX speed after the MIN speed and it may be necessary to repeat the sequence until both the MIN and the MAX speeds are set to the desired levels D Current Limit CL Torque Adjustment CL circuitry is provided to protect the motor and control against overloads The CL also limits the inrush current to a safe level during startup The CL is factory set to approximately 1 5 times the full load rating of the motor CL trimpot is nominally set to approx 50 of full CW rotation Note The correct value Plug in Horsepower Resistor must be installed in order for the CL and IR comp to operate properly Calibration of the CL amp IR comp is normally not required when the proper Plug in Horsepower Resistor is installed To set the CL to factory
5. See Page 3 A COMPLETE LINE OF MOTOR DRIVES KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions See SAFETY WARNING on page 4 Basic KBIC PATENTED 1996 KB ELECTRONICS INC TABLE OF CONTENTS Section Page i Safety Warning 3 ii Simplified Instructions 3 iii Introduction 6 I Application Information 6 II Installation Instructions 7 III Adjustments amp Control Functions 10 IV Switch
6. seconds D Limitation in Use The KBIC controls are designed for use on machine applications E Armature Switching Do not switch the armature without taking proper precautions See sec IV p 11 CAUTION Consult factory before using on constant horsepower applications such as saws or drill presses Do not use in explosive atmosphere Be sure the KBIC is used within its maximum ratings Follow all installation instructions carefully Refer to section II 6 FIG 2 MECHANICAL SPECIFICATIONS 3 2 1 CONTROL DWG D2600 1 00281 1 375 1 250 7 000 3 110 6 250 5 625 5 625 0 500 0 982 438 0 125 PIN ROTATION ANTI BUSHING 3 8 32 1 4 ROUND ALUM SHAFT 3 8 1 2 POTENTIOMETER OPTIONAL AUXILIARY HEATSINK II INSTALLATION INSTRUCTIONS A Location and Mounting The KBIC controls should be mounted on a flat surface and located in an area where it will not be exposed to contaminants such as water metal chips solvents or excessive vibration When mounting in an enclosure the air space should be large enough to provide adequate heat dissipation The maximum allowable ambient temperature at full rating is 45 C 113 F Consult factory if more information is required B Initial Setup and Wiring 1 Install proper size Plug in Horsepower Resistor See chart 2 The KBIC can be connected to a standard 115V or 230V 15 50 60 Hz AC line based on model selected Be sure
7. specifications adjust as follows 1 Set main speed potentiometer at approximately 30 50 CW rotation Set CL trimpot to full CCW position 2 Connect a DC ammeter in series with the armature lead 3 Lock shaft of motor be sure CL pot is in full CCW position Apply power and rotate CL pot CW slowly until DC ammeter reads 1 5 times motor rating do not exceed 2 times motor rating Note Complete this step within 5 seconds to avoid damaging motor Note If only an AC ammeter is available it can be installed in series with AC input line Follow above instructions however set AC amperage at 0 75 times motor rating E IR Compensation Adjustment IR compensation is provided to substantially improve load regulation If the load presented to the motor does not vary substantially the IR adjustment may be set at a minimum level approximately 1 4 of full setting The control is factory adjusted to approximately 3 regulation If superior performance is desired less than 1 speed change of base speed from 0 to full load then the IR comp should be adjusted as follows Note Excessive IR comp will cause control to become unstable which causes motor cogging 1 Set IR comp trimpot at approximately 25 of CW rotation Run motor unloaded at approximately 1 3 speed and record RPM 2 Run motor with maximum load and adjust IR comp trimpot so that the motor speed under load equals the unloaded speed per step 1 3 Remove load and
8. terminated as standard with Q D terminals A Barrier Terminal Board is available which incorporates both line and armature fuses The Inhibit circuit Terminals I1 and I2 is provided to electronically disconnect the armature output voltage Another standard feature is Auto Inhibit This circuit prevents false starts and high surge currents when cycling the KBIC control with the AC line All models are UL Recognized for the USA and Canada and CE approved I APPLICATION INFORMATION A Motor Type The KBIC is designed for Permanent Magnet PM Shunt Wound and Universal AC DC motors Controls operated on 115 volt AC inputs are designed for 90 volt SCR rated motors Controls operated on 230 volt AC inputs are designed for 180 volt SCR rated motors Use of higher voltage motors will result in reduction of available MAX speed Also if motor is not an SCR rated type the actual AC line amperage at full load should not exceed the motor s DC nameplate rating B Torque Requirements When replacing an AC induction motor with a DC motor and speed control consideration must be given to the maximum torque requirements The full load torque rating of the DC motor must be equal to or greater than that of the AC motor C Acceleration Start The KBIC contains an adjustable acceleration start feature which allows the motor to smoothly accelerate from 0 full speed over a time period of 0 5 4 seconds The ACCEL is factory set at 2
9. 0 1 5 1 0 1 1 8 1 4 1 3 2 1 6 1 3 1 7 3 1 4 1 2 2 5 4 1 3 3 4 3 3 5 1 2 1 5 0 8 3 4 1 7 5 12 1 2 10 0 15 1 3 15 0 25 Note Specific applications may require a different fuse value than indicated This is based on several factors such as ambient temperatures duty cycle motor form factor and CL setpoint FIG 1 FEATURES AND FUNCTIONS 1 Plug in Horsepower Resistor 2 Mounting Holes for Armature and AC Line Fuses 3 Trimpots MIN MAX ACCEL IR amp CL 4 Auxiliary Heatsink optional see fig 2 p 7 TABLE 5 PLUG IN HORSEPOWER RESISTOR CHART 1 Motor Horsepower 2 Approx Motor Current DC Amps Plug in Horsepower Resistor Value Ohm Individual Plug in Horsepower Resistor P N Armature Voltage 90VDC Armature Voltage 180VDC 1 100 1 50 0 1 1 0 9833 1 50 1 25 0 2 0 51 9834 1 30 1 25 1 15 0 35 0 35 9835 1 20 1 10 0 5 0 25 9836 1 15 1 12 1 6 0 8 0 18 9837 1 10 1 8 1 6 1 4 1 3 0 1 9838 1 4 1 2 2 5 0 05 9839 1 3 3 4 3 3 0 035 9840 1 2 1 5 0 0 025 9841 3 4 1 7 5 0 015 9842 1 2 10 0 0 01 9843 1 3 15 0 0 006 9850 Notes 1 Motor horsepower and armature voltage must be specified in order to select correct Plug in Horsepower Resistor 2 For motor horsepower not indicated use lower value Plug in Horsepower Resistor 5 iii INTRODUCTI
10. ATINGS Model Number AC Line Voltage VAC 15 50 60Hz Motor Voltage VDC 3 RATING WITHOUT AUXILIARY HEATSINK RATING WITH AUXILIARY HEATSINK FIELD VOLTAGE Shunt wound Motor Only VDC Max AC Load Current RMS Amps Max DC Load Current Avg Amps MAX HP Max AC Load Current RMS Amps Max DC Load Current Avg Amps MAX HP KBIC 120 115 0 90 9 0 6 0 0 5 18 0 12 0 1 50 100 KBIC 125 115 0 90 12 0 8 0 0 75 24 0 16 0 1 5 50 100 KBIC 240 230 0 180 9 0 6 0 1 18 0 12 0 2 100 200 KBIC 225 230 0 180 12 0 8 0 1 5 24 0 16 0 3 100 200 KBIC 240D1 115 0 90 9 0 6 0 0 5 18 0 12 0 1 50 100 230 0 180 1 2 100 200 KBIC 240DS2 115 230 0 90 9 0 6 0 0 5 18 0 12 0 1 100 Notes 1 Model KBIC 240D is designed to accept 115 or 230 VAC line input to provide 0 130 VDC with a 115 or 230 VAC line and 0 220 VDC with a 230 VAC line 2 Model KBIC 240DS is designed to accept 115 or 230 VAC line input to provide 0 130 VDC with a 115 or 230 VAC line Also see Information Sheet A40058 3 A higher output voltage can be reached by increasing MAX trimpot setting TABLE 3 GENERAL PERFORMANCE SPECIFICATIONS Speed Range ratio 50 1 Load Regulation base speed 0 full load 50 1 speed range 1 Line Voltage Regulation b
11. ON Thank you for purchasing the KBIC Standard of the Industry DC motor speed control They are designed for applications demanding good performance high reliability and low cost The controls are fabricated with components that have proven reliability including MOV transient protection which is used to protect the power bridge Integrated circuitry is used to provide an uncomplicated design with superior load and line voltage regulation The patented Direct Fed current limit circuit protects the motor and control against overloads by limiting the maximum level of output current It also prevents motor failure due to demagnetization of the magnets of PM motors Acceleration start adjustable from 0 5 to 4 seconds provides a smooth start each time the AC power is applied A unique feature of the KBIC control is the Plug in Horsepower Resistor It eliminates the need to recalibrate IR Comp and CL when the control is used over a wide range of motor horsepower Additional versatility is achieved by using the Auxiliary Heatsink optional which is used to double the horsepower rating of each model The output of the control is a linear function of potentiometer rotation The KBIC can also be operated in a voltage following mode by supplying an isolated analog signal 0 7 VDC to the input terminals P2 and F If an isolated input signal is not available the optional Barrier Terminal Board Signal Isolator SI 5 can be used The controls are
12. ase speed at full load 100 130 VAC 1 2 Control Linearity speed vs dial rotation 2 CL Torque Range full load 0 300 ACCEL Time Period 0 full speed secs 0 5 4 0 MIN Speed Trimpot Range full speed 0 30 MAX Speed Trimpot Range full speed 50 110 IR Compensation Trimpot Range at specified full load volts 0 24 Maximum Allowable Ambient Temperature at full rating C F 45 113 Maximum Inrush Start Current Peak DC amps 3 times CL Setting PLUG IN HORSEPOWER RESISTOR A Plug in Horsepower Resistor must be installed to match the KBIC to the motor horsepower and voltage See table 4 p 5 for the correct value Plug in Horsepower Resistors are stocked by your distributor Performance is for SCR rated PM motors only Lower performance can be expected with other motor types Factory setting is for 3 load regulation To obtain superior regulation see sec III E p 11 4 FIG 1 BASIC KBIC TABLE 4 FUSE SELECTION CHART 90 VDC Motor 180 VDC Motor Approx Motor Current DC Amps Fuse Rating AC Amps HORSEPOWER 1 100 1 50 0 1 2 10 1 50 1 25 0 2 3 10 1 30 1 15 0 3 1 2 1 20 1 10 0 5 3 4 1 15 1 8 0 7 1 1 1
13. e The input circuits of this control potentiometer Inhibit are not isolated from AC line Be sure to follow all instructions carefully Fire and or electrocution can result due to improper use of this product This product complies with all CE directives pertinent at the time of manufacture Contact factory for detailed installation instructions and Declaration of Conformity ii SIMPLIFIED INSTRUCTIONS Read these simplified instructions before operating control See Safety Warning 1 Be sure input AC line voltage corresponds to control voltage See Electrical Rating chart table 2 p 4 2 Install the correct Plug in Horsepower Resistor according to armature voltage and motor horsepower See chart p 5 3 Recheck connections AC line to L1 and L2 armature to A and A and Field Shunt motors only to F and F Note if motor runs in improper direction interchange armature leads 4 Nominal trimpot settings are as follows expressed in of full CW rotation 5 It is recommended that both AC line and armature fuses should be installed in this product See sec IID p 9 TABLE 1 NOMINAL TRIMPOT SETTINGS For detailed instruction see Sec III MIN minimum speed 15 CL current limit torque 50 MAX maximum speed 60 ACCEL acceleration start 50 IR IR Compensation 25 3 CAUTION Be sure Plug in Horsepower Resistor is inserted completely into mating socket TABLE 2 ELECTRICAL R
14. ic braking The APRM is built in as standard in all KBCC R suffix models and in all KBPB models Patented FIG 5 APPLICATIONS A Master Slave Connections The KBIC can be used with the KBSI to drive multiple motors a From a single main potentiometer b From a single main motor FIG 5A MASTER SLAVE CIRCUIT connect high side of potentiometer to terminal P QD 12 FIG 5B DYNAMIC BRAKE CIRCUIT Using Inhibit Notes Dynamic Brake Circuit Choose RB resistance and wattage according to braking requirements Inhibit circuit extinguishes output of control during brake When the armature is reenergized the Inhibit releases which allows for a smooth start C Overload Protection with KBAP 240D P N 9106 Optional The KBAP 240D is a multipurpose DC Current Sensing Relay and Overload Protector It is specifically designed for use with DC motors and speed controls from 1 8 3 HP KBAP 240D operates by sensing current in the armature circuit When the preset level is reached the output relay RY1 trips An adjustable time delay 0 2 15 secs is incorporated which eliminates nuisance tripping Manual or automatic reset is provided at the user s option along with a LED which indicates when the preset current level has been reached When an overload occurs the KBAP 240D can be used to shut the system down sound an alarm or initiate corrective action before damage occurs In
15. ing Circuits 11 V Limited Warranty 16 TABLES 1 Nominal Trimpot Settings 3 2 Electrical Ratings 4 3 General Performance Specifications 4 4 Fuse Selection Chart 5 5 Plug in Horsepower Resistor Chart 5 6 Minimum Supply Wire Requirements 8 7 Field Connections
16. recheck unloaded RPM If unload RPM has shifted repeat procedure for more exact regulation The control is now compensated to provide minimal speed change under large variations of applied load IV SWITCHING CIRCUITS A AC Line Switching The KBIC can be safely turned on and off rapidly using the AC Line no waiting time is required Auto Inhibit circuitry contained in the KBIC automatically resets critical components each time the AC line is interrupted This along with Acceleration Start and CL will provide a smooth start each time the AC line is connected 11 A 10K ratio potentiometer is used to control up to 10 slave motors If a 5K ratio potentiometer is used up to 5 slave motors can be controlled 1 Multiple KBIC controls should be powered from the same phase AC line 2 The positive output terminal to each speed control must be installed with a 1A 600PIV isolation diode Warning Do not disconnect and reconnect the Armature with the AC line applied or catastrophic failure will result B Armature Switching If the armature is to be disconnected and reconnected with AC power applied the Inhibit Circuit must be simultaneously activated and deactivated Connect I1 and I2 together to activate the Inhibit Circuit See fig 5B for dynamic brake circuit C Reversing and Dynamic Braking KB has developed the APRM which provides anti plug instant reversing and solid state dynam
17. signal wires to P2 and F with AC line or motor connections If signal wires are over 18 inches use shielded cables D Fusing The KBIC has provision for adding a built in AC line fuse and armature fuse The AC line fuse protects the control against catastrophic failure If the fuse blows the control is miswired the motor is shorted or grounded or the KBIC control is defective The armature fuse provides overload protection for the motor and control Choose the proper size armature fuse and AC line fuse see fuse chart table 4 p 5 by multiplying the maximum DC motor amps by 1 7 Armature and AC line fuse kits are available from your distributor On domestic 230 Volt AC lines separate branch circuit protection for each line must be used All fuses should be normal blow ceramic 3AG or MDA or equivalent The Barrier Terminal Kit optional contains prewired AC line and armature fuses Contact your distributor 9 FIG 4 ACCEL TRIMPOT ADJUSTMENT III ADJUSTMENTS AND CONTROL FUNCTIONS The KBIC is factory adjusted to provide 0 to full speed range using a 5K potentiometer Minimum and maximum speed trimpots are provided to change the speed range from other than 0 to full speed An acceleration start located directly behind the MIN trimpot is factory set to provide motor acceleration from 0 to full speed over a time period of 2 seconds approx each time the AC power is applied The current limiting CL or torque output adjustmen
18. t is factory set to approximately one and a half times the motor rating The IR Compensation IR is factory adjusted to provide excellent motor regulation under normal operation NOTE In order for the IR comp and CL trimpot settings to be correct the proper Plug in Horsepower Resistor must be installed for the particular motor and input voltage being used Do not attempt to change the settings of the trimpots unless absolutely necessary since they are factory adjusted to near optimum settings IMPORTANT NOTE Readjusting the ACCEL time will affect the MAX speed and IR Comp settings which will have to be readjusted see this Section If the ACCEL time is decreased to the minimum time of 0 5 seconds 6 o clock trimpot position then increase the IR trimpot 25 CW rotation and decrease the MAX trimpot 20 CCW rotation If the ACCEL time is increased to the maximum time of 4 seconds full rotation then decrease the IR and increase the MAX as per above percentages of rotation The following procedure is presented in required order of adjustment It should be followed when readjusting all trimpot functions A Acceleration Start ACCEL trimpot is located directly behind the MIN trimpot If the ACCEL is to be readjusted to different times adjust the trimpot to the desired time according to fig 4 B Maximum Speed Adjustment Set main speed pot to full speed maximum CW position Adjust MAX speed trimpot to new desired setting
19. ternal Sensing Wire the KBAP in accordance with the following wiring diagram 13 V LIMITED WARRANTY KBIC For a period of 18 months from date of original purchase KB will repair or replace without charge devices which our examination proves to be defective in material or workmanship This warranty is valid if the unit has not been tampered with by unauthorized persons misused abused or improperly installed and has been used in accordance with the instructions and or ratings supplied The foregoing is in lieu of any other warranty or guarantee expressed or implied and we are not responsible for any expense including installation and removal inconvenience or consequential damage including injury to any person caused by items of our manufacture or sale Some states do not allow certain exclusions or limitations found in this warranty so that they may not apply to you In any event KB s total liability under all circumstances shall not exceed the full purchase price of this unit rev 4 88 The information contained in this brochure is intended to be accurate However the manufacturer retains the right to make changes in design which may not be included herein KB ELECTRONICS Inc 12095 NW 39th Street Coral Springs FL 33065 954 346 4900 Fax 954 346 3377 Outside Florida Call TOLL FREE 800 221 6570 A40202
20. trophic failure can result Always disconnect control from secondary side of transformer CAUTION Do not bundle potentiometer connections P1 P2 P3 and Inhibit connections I1 I2 with AC line or motor wires WARNING Armature Switching Do not switch the armature in and out of circuit or catastrophic failure will result If armature switching is required for dynamic brake or reversing use model KBRG KBPB or KBCC R suffix controls NOTE Shunt motors only For 90V DC motors with 50VDC fields and 180VDC motors with 100VDC fields use half voltage field connections F and L1 See table 7 p 8 C Voltage Following All models can be controlled with an isolated analog reference voltage 0 7 VDC in lieu of the main speed potentiometer The voltage is connected to P2 and F The control output voltage will linearly follow the input voltage The source impedance of the input should be 10K ohms or less The Min and Max trimpots are rendered inoperative in the voltage following mode Use auxiliary trimpots for scaling and to limit the control range If the input signal is not isolated or is a current signal 4 20 mA the KBSI 240D or SI 5 Barrier Terminal Board Signal Isolator must be used It will allow direct connection to process controllers and microprocessors CAUTION 1 The voltage feeding P2 and F must be isolated from the AC line Do not earth ground P2 or F to setup a zero or ground reference 2 Do not bundle