Instruction manual for installation on pellet burner GP 45 with U-22

image

Contents

1. e number of sections of the boiler and its nominal thermal capacity e the range of the ash contamination and the resulting thermal resistance of the ash deposits layer e the air tightness of the boiler s doors i e the condition of the thermal resistant ropes e chimney s draught and position of the flap at the flue gases exit of the boiler The effective efficiency of a system automatic pellet burner GP45 and a hot water boiler VIADRUS U22 at nominal thermal load reached 82 for a 7 section boiler this is achieved by adjustment of the operating parameters of the combustion process performed by specialist The efficiency is affected by the number of the sections of the boiler as well as the ash deposition and the overall condition of the boiler The practice shows that at increased number of sections the efficiency of the systems 1s increasing as well 1 4 Procedure for reconstruction of hot water boiler VIADRUS U 22 with automatic pellet burner GP45 1 4 1 Clean thoroughly the internal heat exchanging surfaces of the boiler clean ash residue char and tar deposits which could increase the thermal resistance of the surfaces and reduce the overall efficiency of the boiler p 7 31 a _ Siete ra f e ae Nuts fixing the lower door s knuckle the boiler ss Ris gt Ce i os ev P a SEE e r a bg a a 7a w Fry iy Fey FS 5 r b i 4 5 Q aye a es pii et z
2. which utilizes common energy source oil gas electricity for example However the price of the achieved heat energy 1s competitive to the price of the above mentioned energy sources as well as the wood pellets are local product less influences by the world trends of energy sources prices and is ecological and environmentally friendly The burner could utilize following types of fuel e Wood pellets complying the requirements of ENplus Al having diameter 6 and 8 mm also categorized in the range of A AB B according to the methodology developed for pellets properties estimation in ERATO company e Pre dried pits cherries for example e Fuel mixture pellets and pits for example mixture ratio could be 50 50 e Other solid biomass based pellets but these fuels need testing and approval in ERATO company laboratory The burner s modules are e adjustable operating module which controls the functions of the unit and is adjustable to the specific needs of a heating system e auger which transports fuel from a bunker to the main unit e fresh air supplying fan equipped with a Hall sensor which returns information to the control unit e electric heater which ignites the fuel e combustion chamber which gives environment for efficient combustion process e removable grate of the combustion chamber allowing easy access and ash cleaning p 5 31 photosensor which gives information for the status of the combu
3. N i SS ope f Figure 1 4 1 Front view of hot water boiler VIADRUS U22 version C with both doors opened 1 4 2 Take away the triangle shaped grate positioned in the lower door of the boiler Figure 1 4 2 The triangle shaped grate is taken away p 8 31 1 4 3 Detach the lower door of the boiler by unscrewing the fixing nuts of the door to the heat exchanger In case the lower door has not been processed before the automatic pellet burner installation than it has to be detached and an orifice should be made Then the burner will be attached on the door by using the attachment flange applied in the kit of the pellet burner This attachment flange should be installed on the door but the fixing bolts should be left uptight loosened which will allow easy installation of the pellet burner by using bolts M8 The following figure shows a chart which should used in order to transform the door of the boiler in order to run on wood pellets as fuel After the door has been manipulated and the orifice for the flue gases of the burner has been made the attachment flange should be installed RECOMENDATION the orifices for the fixing of the bolts which will be used to fix the attachment flange of the burner should be made on site i e when the position of the attachment flange is clarified and the orifice for the burner s head is made EXPLANATIONS The flap for the primary air installed on the lower door of the
4. and replace if necessary The status i e their ability to make air tight gasket of the doors of the heat resistant ropes of the doors should be checked and renewed if necessary and air tightness should be guaranteed p 16 31 2 Lower door of the i combustion chamber of the l boierl i I BPa aN aE 2 Attachment flange whichis used to install the automatic l Pellet burner of series GP45 l l l Figure 1 4 11 The manipulated lower door of the boiler has been reattached to the boiler The door has installed the attachment flange for installation of the automatic pellet burner of series GP45 1 4 6 Install the automatic pellet burner GP45 on the attachment flange attached to the lower door of the boiler p 17 31 Figure 1 4 12 The automatic pellet burner of series GP45 is installed on the lower door of the cast iron hot water boiler VIADRUS U22 view from the internal side of the doors of the boiler EXPLANATION the pellet burner of series GP45 is installed in such a way that its frontal surface should be leveled with the surface of door at the internal side of the door Such an installation approach allows reliable and optimal operation of the burner and the entire system as well as high intensity of the hot flue gases emitted from the burner s head to the combustion chamber of the boiler The producer reserves the right to change the specification and or the des
5. information The adjustment of the operating parameters of automatic pellet burner GP45 is made following the instructions in the burner s manual It 1s recommended to use specialized device flue gas analyzer in order to achieve optimized combustion process and high efficiency of the system pellet burner and hot water boiler The adjustment process should be performed by authorized technician only 2 2 Requirements of the fuel which will be utilized by automatic pellet burner GP45 Requirements for the properties of recommended solid biomass fuel properties wood pellets are given in burner s manual as well as in the following tables _ Parameter Dimension Value Pellet s characteristic size gt m 6 8 Recommended fuel net calorific value MJ kg kWh kg Wood pellet class according to ENplus ENplus A1 Wood pellets category according to A AB B ERATO classification O a e See Table 2 2 2 Max 8 10 Table 2 2 1 Recommended solid biomass fuel properties wood pellets Classification of wood pellets considering their physical properties based on fuel proximate analysis according to fuel evaluation method developed and applied in ERATO company is show on the following table p 20 31 AA 06 DUE 97 0 ABA 506 DU lt 97 0 B _ 06 lt A 51 0 DU gt 97 0 BC 06 lt A 51 0 DU lt 970 1 0 lt A lt 2 0 1 0 lt A lt 2 0 Df 20 lt 4
6. minimal values of CO fraction in the flue gases Ce ee eel el gt De ee Bl e e e e e m 27 LD Oo 5 e ewe eww ew Bw Bw Bw Bw eB eB eB ee Ne eB BB BB BB BE BP BEB BM BB BB BM BB BB BP BB BP BB BB BB BP BB EB BEB BB EB SB EB SE EK EK SK LG Range of optimal value of air excess ratio which allows high efficiency of the combustion process Figure 2 5 1 Characteristic function of CO mass fraction in the flue gases and the air excess ratio A The above information shows that low values of air excess ratio results in increased CO mass fraction in the flue gases the process is explained with inefficient mixing of the air flow and the combustible gases of the fuel In practice it 1s possible such kind of combustion process low air excess ratio and high amount of CO and unburned hydrocarbons to result in char residue deposits on the heat exchanging surfaces which will result in decreased efficiency of the system pellet burner hot water boiler However increased air flow rate i e the air excess ratio is above the optimal range will result in increased CO mass fraction in the flue gases due to increased cooling effect of the fresh and relatively cool air on the combustion process despite the increased turbulent intensity and intensified mixing process The above mentioned shows that precise adjustment of the operating parameters which define the combustion process should b
7. operating mode of the burner the pellet burner resetting should be performed by the main power circuit breaker for the power supply of the boiler 2 4 Nominal thermal capacity of pellet burner GP45 installed on hot water boiler VIADRUS U22 After the burner has been started 1 e successful ignition and the boiler has reached steady state operation mode it is heated up as well as the heating installation it could be assumed that the entire system the pellet burner the boiler and the heating system is in steady state mode The burner s operating parameters should be adjusted in this mode The burner s air flow control flap should be adjusted as well in order to achieve efficient combustion process and optimal performance of the system The nominal thermal load of the system should be utilized on order to perform the so called hot test of the heating system considering the requirements of the governing norms Notes e Ifa circulating pump is installed in order to transport the heat energy of the boiler to the consumers it is recommended to control the inflow temperature to the boiler to be above 60 C In case of low inflow temperature level condensation of water vapor could be observed on the internal heat exchanging surfaces please consider that water vapor is one of the final products of the combustion process and always persist in the flue gases of the boiler e It is not recommended to operate the sy
8. transport Explanation the angle between the axis of the fuel transport auger and the horizontal plane directly influence the fuel flow rate delivered by the auger Thus in case that the position of the auger has been changed i e the above mentioned angle has been changed a new adjustment of the operating parameters of the burner could be required in order to achieve high efficiency of the burner and its reliable functionality 1 4 9 Connection of the fuel transport auger to the main unit of automatic pellet burner GP45 Connect the fuel transport auger to the main unit of the automatic pellet burner GP45 according to the instructions depicted in the burner s manual Explanations e The producer reserves the right to change the design of the transition kit which allows installation of automatic pellet burner GP45 on a hot water boiler VIADRUS U22 without prior notice e Prior to initial startup of the burner as well as in case that the fuel in bunker has been totally consumed then the auger should be refilled with fuel the procedure is described in details in the burner s manual The auger s fuel refilling procedure should be explained and demonstrated to the client maintenance personal of the system pellet burner hot water boiler p 19 31 2 Adjustment of operating conditions of automatic pellet burner GP45 installed on a hot water boiler VIADRUS U22 2 1 Preliminary
9. Instruction manual for installation operation and maintenance of automatic pellet burner GP45 on solid fuel hot water boiler VIADRUS U22 boiler version C and D www greenecotherm eu Producer ZMM Haskovo Plc Address Bulgaria Haskovo 6300 Saedinenie 67 blvd Phone 359 800 15 145 Fax 359 38 603070 e mail ereenecotherm erato bg home page www greenecotherm eu Thank You for buying our products automatic pellet burner GP45 and burner s installation kit This manual will help You to install use and maintain the unit properly ATTENTION IN INTEREST OF YOUR PERSONAL SECURITY IT IS NECESSARY TO READ THOROUGHLY AND CAREFULLY THIS INSTRUCTION MANUAL BEFORE PROCEEDING WITH ANY ACTIONS WITH THE BURNER INSTALLATING CONNECTING OPERATING ETC IN CASE THAT REQUIREMENTS DEPICTED IN THIS MANUAL ARE NOT SATISFIED FAILURE OF THE UNIT COULD BE EXPECTED OR EVEN FATAL CONSEQUENCES FOR WHICH PRODUCER COMPANY DOES NOT TAKE RESPONSIBILITY e According to Bulgarian government decree MC Ne 187 21 09 2000 the boiler VIADRUS U22 should be treated as high risk equipment and should be reported by the end user to the regional technical supervision register e In interest of your personal security it 1s necessary to read thoroughly and carefully this instruction manual before proceeding with any actions with the burner as well as with the boiler installation connect
10. ber of the boiler These plates allow multi tract flue gas dynamics in the combustion chamber and increase the overall efficiency of the system hot water boiler VIADRUS U22 and the automatic pellet burner Attention the installation of the above mentioned directing plates is obligatory their appropriate and correct arrangement will allow high efficiency and reliable operation of the automatic pellet burner GP45 installed on the hot water boiler VIARDUS U22 p 12 31 Figure 1 4 6 Principal arrangement the distance between the plates is intentionally in order to show their arrangement on the picture of directing plates which are mounted in the combustion chamber of the boiler Explanation e The directing plates are parts of the kit for hot water boiler s reconstruction which allows fuel switch to wood pellets and automatic performance of the heating unit e The number count of the so called straight plates which should be installed in the combustion chamber of the boiler depend on the number of boiler s sections Additional information is given in Table 1 4 1 e The arrangement of the directing plates should be made in appropriate order start with installing over the special steps of the sections of the boiler the most internal straight directing plate and continue in direction out of the combustion chamber of the boiler The last directing plate is the so called curved one and all t
11. boiler should be fixed at closed position as well as the flap which is installed on the upper door also fixed closed The tightening ropes which are installed on the doors should be checked and replaced if necessary In case of uptightness special care should be taken in order to ensure the proper operation of the boiler flue tightness p 9 31 4xM8 35 210 Primary air flap should be fixed at closed position Figure 1 4 3 Chart for manufacturing the lower door of the hot water boiler VIADRUS U22 front side view p 10 31 Figure 1 4 4 Front side view of the lower door of the hot water boiler of series VIADRUS U22 has been manipulated in order to operate with burner of series GP45 1 4 4 Install the attachment flange of the pellet burner of series GP45 on the lower door of the boiler Explanation the attachment flange should be tightened only after the burner has been installed then all the fixing bolts and nuts should be tightened in order to ensure stable and reliable installation of the pellet burner to the hot water boiler s door p 11 31 Figure 1 4 5 Attachment flange and the automatic pellet burner of series GP45 1 4 5 Position the applied directing plates so called straight and curved cast iron plates which should be arranged close to each other on a intentionally produced internal steps at the internal surface of the combustion cham
12. d on a hot water boiler VIADRUS U22 0000 cecccccceeeeees 20 2 1 Preliminary information cc ecccccccccceessseeceeeeeaaeeeeeeeeeesaaenees 20 2 2 Requirements of the fuel which will be utilized by automatic pellet PUREE GS erona re A dose daigs wows cus E E E E 20 Table 2 2 1 Recommended solid biomass fuel properties wood pellets 20 Table 2 2 2 Pellets classification considering their physical properties according to the methodology developed by ERATO company 21 2 3 Operating parameters of automatic pellet burner GP45 21 2 4 Nominal thermal capacity of pellet burner GP45 installed on hot water boiler VIADRUS 22 iss eis hiartssermbiscienerdntankn eons eink 23 2 5 Combustion process adjustment c cc ccccccccsseeccceeaeeeeeceesaeeeees 24 2 6 Combustion process adjustment algorithm cccccceeeeeees 26 2 7 Adjustment of the thermal capacity of the system automatic pellet burner and hot water Doiler ccc ccccssseeccccceaeseeeceeeeeaaeeeeeeeeseeaeeeees 27 2 7 1 Decreasing the thermal capacity of the boiler 0 28 2 7 2 Increasing the thermal capacity of the boiler 00 28 2 8 Stopping the system pellet burner hot water boiler 28 2 9 Turning the burner OFF 0 ccc cc cccccccccecaeeecceeaaeeeceeeaaeeeeees 28 e Emergency system pell
13. e performed by authorized and trained technician by flue gas measurement utilizing gas analyzer 2 6 Combustion process adjustment algorithm p 26 31 The adjustment of the operating parameters of automatic pellet burner GP45 are given in their respective manuals e First of all one should adjust the operating parameters which define the fuel flow rate and the thermal capacity of the system It is strongly recommended to perform fuel flow rate measurement as well as to position the air flow rate control flap in position up to 1 2 opened e Perform precise adjustment of the position of the air flow control flap as follows o In case that the air excess ratio A is above the recommended operating range then the flap should be slightly closed o In case that the air excess ratio A is below the recommended operating range then the flap should be slightly opened Explanations e The adjustment process should be done in small steps in case that any operating parameter has been changed then certain period of time should pass in order to observe the influence of this manipulation on the combustion process and the overall behavior of the system in practice it is recommended to wait at least 15 minutes before taking further actions e In case that the air flow control flap is adjusted in direction to decrease the air flow rate i e it is closed it is possible to observe increased air excess ratio this is exp
14. em pellet burner hot water boiler should be cooled down and the reason for such emergency situation should be investigated and preventive measures Should be performed The emergency thermostat should be manually reset by unscrewing its preventive cap and its stem should be pressed until the thermostat switches back on a click sound is heard in this process then screw back its cap After the system burner heat consumer boiler is checked and the cause for overheating is determined and repaired restart the burner turning off its power supply and then back on in order to run the burner in normal mode in case of alarm mode burner s fuel delivery pipe overheating the burner will go into alarm mode See the burner s manual for further details Demonstrating and teaching the end user about the maintenance and adjustment procedures of the system pellet burner and hot water boiler The end user should read thoroughly the manuals of the pellet burner and the hot water boiler It is necessary to show and teach the end user client all maintenance procedures for operating the burner as well as the boiler efficiently and keep their reliability in high degree order Also the installer should demonstrate and teach the end user how to adjust the thermal capacity of the p 29 31 pellet burner according to the estimated heat consumption and initial fuel transport auger charging e Fuel bunker charging the fuel is poured out of t
15. er OFF The pellet burner GP45 is turned off following the detailed procedure described in their respective manuals After the burner has been cooled down to ambient temperature it should be switched off by turning off the main power p 28 31 supply It 1s recommended to clean the deposited ash thoroughly both of the burner as well as hot water boiler heat exchanging surfaces e Emergency system pellet burner hot water boiler stop In operating process of the pellet burner GP45 emergency situations could arise and the unit will go into alarm failure mode Such situations are detected by the process control unit of the burner and it will go into automatic protective mode in order to be protected as well as the hot water boiler These modes are operated by appropriate preventive measures automatically taken by the control board of the main module and the ALARM indicator light could be activated Please check the status of the burner s control unit and refer its manual before taking any actions After the cause of the alarm situation is clarified take adequate actions for bringing back the burner into normal operating conditions and restart it see burner s manual as well ATTENTION 3 in case of emergency situation hot water boiler overheating the emergency thermostat which is not part of the burner s equipment and is installed on the control box of the boiler is activated In this case the syst
16. et burner hot water boiler stop 29 3 Demonstrating and teaching the end user about the maintenance and adjustment procedures of the system pellet burner and hot water boiler 29 4 Operation faults and repairing procedures cccccccccceseeceeeeee sees 31 p 3 31 1 Description of reconstruction procedure of solid fuel hot water boiler VIADRUS U22 to operate with automatic pellet burner GP45 1 1 Description of solid fuel cast iron hot water boiler VIADRUS U22 version C or D The hot water solid fuel boiler VIADRUS U 22 version C and D is designed to be connected in local heating systems which could be realized both with gravity driven circulation of the fluid as well as forced circulation applied by circulating pump The boiler consists of n cast iron sections n 4 10 and 1s designed to be manually fuel coal or wood charged through an opening in the upper part of the front section closed by a cast iron door Ash residue removal is manually realized through the lower door of the boiler as well The combustion process is highly optimized due to the specific design of the boiler s grate and combustion chamber configuration However the operation of the boiler the thermal capacity as well as efficiency is strongly dependant of the chimney s natural draught and the flue gas temperature fy A ti NSS 5 Y 7 A N ON UA Figure 1 1 1 Explosion view of sol
17. good initial guess iS Nsystemn 55 70 0 85 Explanation the overall efficiency of the system pellet burner and hot water boiler is strongly dependant on the pellet burner s operating mode as well as the ash residue deposits and the resulting thermal resistance layer on the heat exchanging surfaces of the boiler o Calculate the thermal capacity of the hot water boiler P H ones M pep 0 82 17200 0 00261 36 8kW if the calorific Boiler 4 Sistem value of the fuel is applied in dimension MJ kg In case that the calorific value of the fuel is applied in other dimension for example kWh kg then the calculation is as follows P H ones M pe 0 82 4 77 9 4 36 8 kW boiler 1 system o The same algorithm should be followed for calculating thermal capacity of the hot water boiler in case that the fuel calorific value differs that cited above or the required thermal capacity of the unit is different that in the above example The producer reserves the right to change the factory defined values of operating parameters of the burner without prior notice p 22 31 e During the nominal operation of the burner certain abnormal conditions could arise for example unsuccessful ignition fuel has been consumed etc some of these conditions are indicated on the control board of the burner After the cause of such situations have been clarified and certain precaution measures have been taken it is necessary or reset the
18. he bags in the hopper or any appropriate procedure e Ash cleaning procedure it is necessary to clean thoroughly the ash residue it 1s recommended to do this at least once per day of the burner s grate which will ensure reliable and effective operation of the pellet burner Further information for pellet burner maintenance could be found in its manual The ash deposits cleaning procedure of the hot water boiler is described in its manual as well ATTENTION regular cleaning of ash residue in burner s combustion as well ash deposits on the heat exchanging surfaces will ensure long life reliable exploitation period economic and efficient performance of the system p 30 31 4 Operation faults and repairing procedures In case of faulty operation mode and failures of the system pellet burner and hot water boiler it 1s necessary to know clarify in details the reasons for malfunctioning of the system Detailed information for any operating faults of the burner as well as the boiler is given in their respective manuals The following table gives additional information which could be found useful for an issue investigation and failure overcoming process No fuel ignition not to Fuel is transported the combustion chamber of the burner s unit Flue gases are main emitted out of the boiler Visible deformations of the burner s combustion chamber Other failures not described above Operation Ca
19. he plates should be finally arranged close to each other in order to ensure separate volumes of the combustion chamber p 13 31 Number of Number of Number of the sections curved straight of the boiler plates plates Table 1 4 1 Information for the number of required directing plates which should be installed in the combustion chamber of the hot water boiler VIADRUS U22 Figure 1 4 7 Directing cast iron straight plate installed on specially designed steps of the sections of the hot water boiler only the first plate is installed p 14 31 r 7 3 j 7 Cee gt gt gt N Wel cal iad i A 8 ie Jc TE Figure 1 4 8 Directing cast iron straight plate installed on specially designed steps of the sections of the hot water boiler Figure 1 4 9 Installation of the curved directing cast iron plate on specially designed steps of the sections of the hot water boiler p 15 31 Figure 1 4 10 The entire set of directing cast iron plates has been installed on the specially designed steps of the cast iron boiler EXPLANATIONS e The flaps which are installed on the door of the boiler both the lower flap which controls the primary air flow rate as well as the flap installed on the upper door which controls the secondary and tertiary air flow rate should be fixed at closed position in order to prevent uncontrolled air leakage e Check the tightening ropes of the door
20. id fuel cast iron hot water boiler VIADRUS U2 1 2 Description of automatic pellet burner GP45 GP45 is automatic pellet burner which utilizes wood pellets The burner is designed to be installed on already operating heating boilers or other equipment thus allowing fuel switch procedure to a renewable energy sources biomass The heating boiler or heat consumer could be based on fossil fuel as follows oil p 4 31 gas wood coal etc The installed burner operates on densified fuel wood pellets and the thermal energy resulting from the intensive combustion process is directed to the heat exchange surfaces of a boiler or another thermal consumer The wood pellets allow high level of automation of the operating process of such kind of equipment thus achieving high level of comfort and competitive price of the heating energy delivered by utilizing biomass fuel However the wood pellets are solid fuel as well and ash residue results from the combustion process realized by the automatic burner due to their natural ash content In principal the ash residue quantity is much less compared to the coal or wood logs The ash residue is deposited on the internal surfaces of the boiler and need manual cleaning regularly in order to sustain high heat exchange intensity between the hot flue gases and the water jacket of the boiler The operation of automatic pellet burner GP45 corresponds to the functionality of an automatic unit
21. ign of the transition kit which allows installation of automatic pellet burner GP45 without prior notice 1 4 7 Connection of automatic pellet burner GP45 to the power supply The burner should be connected to the power supply and the appropriate safety rules should be satisfied Follow the instructions described in automatic pellet burner s manual The connection should be done by authorized technician only ATTENTION the boiler should be equipped with operating and alarm thermostat or a combination in a single module so called bi thermostat which controls the operation of the burner following the electrical scheme p 18 31 applied in its manual Explanation These thermostats are not part of the transition kit for installing the automatic pellet burner GP45 and should be delivered and installed by authorized technician 1 4 8 Install the fuel transport auger which feed the burner extracting fuel from a bunker Follow the instructions depicted in the burner s manual The fuel transport auger should be properly installed and should allow fuel transport without difficulties and obstacles The fuel should be extracted from the lowest part of the bunker In case that the bunker is made on site then a so called revision orifice should be made in order to allow easy service and maintenance of the auger The auger s external pipe should be properly positioned and fixed in order to sustain reliable fuel
22. ing adjustment servicing etc in case that requirements depicted in this manual are not satisfied failure of the unit could be expected or even fatal consequences for which the producer company does not take responsibility Instruction manual for installation operation and maintenance of automatic pellet burner GP45 on solid fuel hot water boiler VIADRUS U22 Version 31 03 2011 13 55 Table of contents page 1 Description of reconstruction procedure of solid fuel hot water boiler VIADRUS U22 to operate with automatic pellet burner GP45 4 1 1 Description of solid fuel cast tron hot water boiler VIADRUS U22 VOCUS ION COT D aa a E E E O T AEN N E 4 1 2 Description of automatic pellet burner GP459 000000 4 The burner could utilize following types of fuel 0 cc eccccceeeeeeeees 5 The burner s modules are iactessesdeces cantare sevesanedi seston spadaadanawacdensbbeaatasaneManeniasnts 5 The burner is equipped WIth cece cccssccccccceseecceesaeeeeceeeaeeeeeeseaaeeeees 6 1 3 Basic information for a system automatic pellet burner GP45 and hot water boiler VIADRUS U 22 ooo ecccccccccceseseeecceeesaeeeees 7 1 4 Procedure for reconstruction of hot water boiler VIADRUS U 22 with automatic pellet burner GP49 000 ccc cccccecccceceeeeeeeeaeeeeeeeeas 7 2 Adjustment of operating conditions of automatic pellet burner GP45 installe
23. justment of operating parameters should be performed at nominal thermal capacity 1 e the system is in steady state and no major parameter s fluctuations are observed for example variation of the circulating fluid temperature etc The adjustment of the thermal capacity of the burner is realized by adjustment of the fuel flow rate as well as the air flow rate in order to achieve high efficiency In principal air excess ratio influence could be observed on figure 2 5 1 The optimal value of air excess ratio is achieved by precise adjustment of the air flow control flap as well as fuel flow rate However the practice shows that there are certain variations of the fuel characteristics and its quality in general as well as the chimney s draughts which require individual adjustment of the system pellet burner and hot water boiler installed in a heating system The chimney s draught of the hot water boiler VIADRUS U22 could be adjusted by turning the flue gas flow rate control flap installed on the boiler s flue gas exit considering the recommended operating parameters of the boiler as well as ensuring reliable operating conditions for the pellet burner GP45 However one should consider operating conditions of the burner in order to achieve safe operation of the burner there should be no hot flue gases convection through the fuel delivery pipe this should be achieved by mutual adjustment of the fuel flow rate air flow ra
24. lained by variation of the operating pressure in the combustion chamber of the boiler and respectively with varied increased air flow rate of uncontrolled air passed through certain sections fuel delivery pipe combustion chamber gasket any air untights etc 2 7 Adjustment of the thermal capacity of the system automatic pellet burner and hot water boiler The adjustment of the thermal capacity of the hot water boiler is performed by adjustment of the fuel flow rate delivered by the transport auger of the pellet burner GP45 as well as the air flow rate see the procedure for adjustment of the combustion process Attention in case that the fuel type has been changed for example fuel origin or pellet s quality it is recommended to perform adjustment of the operating parameters of the burner which define its operating mode and overall efficiency p 27 31 2 7 1 Decreasing the thermal capacity of the boiler It 1s performed by decreasing the operating parameters of the burner which define its thermal capacity and will result in decreased fuel flow rate 2 7 2 Increasing the thermal capacity of the boiler It is performed by increasing the operating parameters of the burner which define its thermal capacity and will result in increased fuel flow rate Explanation in case that the thermal capacity of the burner is varied in wide range exceeding 20 of the operating mode then it is recommended to pe
25. r p 21 31 e The producer reserves the right to change the values of the operating parameters of the automatic pellet burner GP45 without prior notice e The adjustment of the heat capacity the system pellet burner and hot water boiler VIADRUS U22 should be performed by adjustment of the fuel flow rate delivered by the auger its gross calorific value and the overall efficiency of the system The following example shows this approach in details o Determine the fuel flow rate for an hour or less for example a shorter period of time 15 minutes 1 4 hour mMjyei 9 4 kg h Calculate the instant fuel flow rate M jie divide fuel flow rate per hour on 3600 where 1 hour 3600 seconds and achieve M me 0 002611 kg s The fuel flow rate could be calculated based on its flow rate at nominal thermal capacity of the burner More details could be found in the burner s manual o Consider the gross calorific value of the fuel for example wood pellets have calorific value Hpenes 17 2 MJ kg 17200 kJ kg In case other dimension of the calorific value is more convenient to apply for example kWh kg then the calculation is as follows wood pellets have gross calorific value of 4 77 kWh kg which is equal to 17 2 MJ kg o Determine consider the net efficiency of the system pellet burner hear consumer unit at nominal thermal capacity mode Nsysten 5270 0 82 If the net efficiency is not know a priory a
26. rform air flow rate adjustment Decreasing the air flow rate is performed by closing the air control flap in reverse increasing the air flow rate is performed by opening the air flow control flap Attention adjustment of the operating parameters which define the thermal capacity of the burner should be performed by authorized technician or trained end user in order to achieve optimal combustion process and reliable operation of the system It is recommended to utilize gas analyzer when adjusting the operating parameters of the combustion process 2 8 Stopping the system pellet burner hot water boiler Stopping the operation of the system should be performed by stopping the operation of the pellet burner For more information refer for the appropriate procedure in the burner s manual ATTENTION n case that the burner boiler will not operate for a long period of time then thorough ash deposit cleaning procedure should be performed The ash layer acts corrosively on the carbon steel surfaces which will lead to a decrease of the lifetime of the burner s main module It is obligatory to perform service procedures and preventive observations of the unit by trained service personal only as well as thorough cleaning at the end of the heating season Completing these requirements will ensure long exploitation duration of the system pellet burner and hot water boiler and their high efficiency and reliability 2 9 Turning the burn
27. s30 2 0 lt A lt 3 0 Table 2 2 2 Pellets classification considering their physical properties according to the methodology developed by ERATO company where A ash contents dry basis DU mechanical durability EXPLANATION detailed information about the requirements for the wood pellets according to ENplus norm is given in the pellet burner s manual 2 3 Operating parameters of automatic pellet burner GP45 The operating parameters of automatic pellet burner GP45 are given in the burner s user manual These parameters determine the operating mode of the burner i e the system burner boiler These parameters their meaning and adjustment procedure should be explained to the end user client in order to allow flexible operation and optimal performance of the system Explanation Any variation of the operating parameter s values should be done only in case that the operating algorithm the physical meaning of the parameters and their influence on the performance of the burner are known for sure It is recommended to adjust the operation parameters by authorized personal only Notes e The corresponding requirements defined in the user manuals of the units of the system burner boiler contain operating parameters and requirements which should be satisfied in order to achieve required thermal capacity high efficiency and reliable operation of the system and the units in particula
28. stem pellet burner and hot water boiler at thermal capacity lower than 50 of its nominal thermal load as such regimes are not optimal and thus have low efficiency Explanation in case that the hot water boiler should operate at thermal capacity lower than 50 of the nominal thermal load it is strongly recommended to install a heat accumulator tank in the heating system in order to achieve high efficiency and reliable performance of the system and the installation p 23 31 e During the very first time of operation the boiler it is possible to observe water vapor condensation on the heat exchanging surfaces of the unit Practically this is one time process and will not affect the performance of the unit neither any problems will arise as well e It is strongly forbidden to operate the automatic pellet burner GP45 at thermal capacity which are above the nominal thermal capacity of the burner or the boiler whichever has lower value In case that this requirement is not fulfilled certain thermal damages could arise both at the combustion chamber of the burner or overheating of the heat exchanger of the boiler These modes are not governed by the warranty of the units and are not recognized by the unit s producers suppliers 2 5 Combustion process adjustment The operating parameters adjustment should be performed by authorized trained technician considering the governing norm s requirements for such type of equipment The ad
29. stion process to the control unit and allows dynamic operation of the burner interface panel equipped with light indicators the control board is equipped with led indicator for indicating the status of adjustable parameters index value a variable potentiometer which allows easy thermal capacity adjustment The burner is equipped with p 6 31 automatic fuel ignition system automatic fuel transport system from bunker to the combustion chamber of the main unit safety system which blocks its operation in case that at any circumstances the fuel delivery pipe is preheated above certain temperature safety level photosensor which allows dynamic monitoring of the combustion process Status process control system which modulated the air supply fan operation at ignition process Figure 1 2 1 Side view of automatic pellet burner GP45 1 3 Basic information for a system automatic pellet burner GP45 and hot water boiler VIADRUS U 22 The automatic pellet burner GP45 is mounted on a transformed redesigned lower door of the boiler utilizing attachment flange However in order to achieve high intensity of the heat exchange rate between the flue gases and the surface of the boiler it is necessary to install a transition kit a kit of specially designed directing elements The achieved thermal capacity of the system automatic pellet burner GP45 and the cast iron hot water boiler depends on
30. te and position of the flue gas flap The combustion process adjustment should be realized covering the flue gases requirements according to EN 303 5 see table 2 5 1 for details The following table a passage consists of the upper limits of the flue gas pollutants defined by EN 303 5 p 24 31 Nominal thermal Flue gas pollutant species concentration limits capacity mg m at 10 O o ee W gt 50n0150 2500 80 150 gt 150n0300 1200 80 Table 2 5 1 A passage of norm EN 303 5 about the flue gases pollutant species limits the above values are based calculated on 10 oxygen volume fraction O2 in the flue gases and are calculated on the basis of following conditions absolute pressure 101325 Pa 1013 mbar and temperature 0 C where CO carbon monoxide mass fraction in the flue gases mg m at 10 O3 OGC organic compound mass fraction in the flue gases chemically bound carbon mg m at 10 O3 Ash mineral matter mass fraction in the flue gases mg m at 10 O3 Attention The air flow rate strongly influences the efficiency of the combustion process and the overall performance of the burner in case that the air flow rate is below certain optimal value then partially unburned fuel will be observed which will result in decreased efficiency However in case that the air flow rate is above certain optimal value the air excess will result in decrease of the tempera
31. ture in the zone of the combustion process which will lead to decreased efficiency of the combustion process and partially unburned fuel as well The optimal air flow quantity is determined by flue gas measurement and individual adjustment of the operating parameters of the system pellet burner and boiler s draught The recommended value of air excess ratio is given in the pellet burner specifications however the flue gases limits requirements should be satisfied as well the flue gas measurements are performed by gas analyzer device Explanation as a rule of thumb the air excess ratio 2 should be as low value as possible but in any case its value should be above 1 0 and the resulting efficiency of the combustion process will be higher and the overall efficiency of the system automatic pellet burner and hot water boiler will be as higher as possible The adjustment of the combustion process will be influenced by the following factors which should be considered p 25 31 e Ambient temperature e Parameters of the environment mainly temperature pressure relative humidity e Dimensions of the chimney as well as the hydraulic pressure losses which determine its draught e Access of the air of the environment to the room where the system burner and the boiler are installed e Other special features any flue gas leakages of door s gasket of the combustion chamber for example CO mg m Range of
32. use fault The electric heater is malfunctioning Fuel transport auger 1S not functioning Certain sections present boiler untight are in the The pellet burner has been overheated due to high thermal capacity Should discussed authorized technician be with Method of repairing Check the electric heater this should be done by authorized technician only Check the status of the auger s electric motor this should be done by authorized technician only Check the connection of the fuel transport auger to the burner s main unit Check the chimney s condition clean if necessary Check the status of the door s gasket this should be done by authorized technician only It is necessary to replace the burner and to perform adjustment of the heat capacity of the system as well as the combustion process this should be done by authorized technician only It is necessary to consult authorized technician and eventually service maintenance should be performed Table 4 1 Description of operating faults of the system automatic pellet burner GP45 and cast iron hot water boiler VIADRUS U22 and methods of repairing p 31 31