Contents

1. 8 In any process press ESC continuous to return to main menu 14 Display Menu L gt 1 Measure l 1 Measure Mode 2 Stake out l Save Data H Y ENT N ESC l Job Name gt B1_ 14 ENT Standard Mode MEAS Press MEAS Rod 0 8050m A Y Dist 8 550m ENT to continue or ESC to quit Pn Num P Standard Mode ESC to Press MEAS quit 3 2 S O GH Stake out Ground Height Under this mode user can stake out by inputting the ground heights GH of backsight point and stakeout point Operation Procedure Display 1 Press ENT ENT Menu gt 1 Measure 2 Press A V to select 2 Stake out ENT 1 Measure Mode ff and press ENT gt 2 Stake out J 3 Select S O GH stake out ground ENT gt 1 5 0 GH a height and press ENT 2 5 0 HD J l Input BSO BS GH 4 Input the ground height of the eig 100 backsight point and press ENT Input BS SO GH 5 Input the ground height of the height 101_ stakeout point and press ENT Meas BS Pt 6 Collimate the staff on backsight point MEAS Press MEAS until it looks clear and press MEAS ENT BRod 0 8050m 7 It displays the backsight staff and the BDist 8 550m distance Press MEAS to measure continuously or press ENT to go to next step or press ESC to quit Meas SO Pt MEAS Press MEAS 8 Collimate the staff on stakeout point until it looks clear and press MEAS SRod 0 65
2. USER MANUAL CONTENTS FOREWORDS ii eie tke eer eb anna PC ERE RR Re e P ERE FER ER RR Pe ERE YER ER TRA 3 GAUGE 4 SAFETY GUIDE 1 teet tn tea te e e ee e POE Rete uel oe C aa 5 OPERATOR EE 6 DECLARATION OF EXCEPTIONAL RESPONSIBILITY ccc 6 1 NAME OF EACH COMPONENT amp ITS FUNCTION ee e 7 1 1 Name of Each Component seems 7 1 2 Operation Keys amp Functions essem 9 IM Mbiielo rec EE 9 2 PREPARATION FOR MEASUREMENT eene 10 2 1 Mounting the INStrUMe Nt ee 10 22 POWER Ooa e arae E Fer rv e ur pen Ere vel ue To ii Fe Vv EN Ea aia 11 2 3 Remaining Battery Display ee 11 2 4 Setting the Data Save Mode oo yi rte 12 2 5 MEIN Menus cfe tre E rte a Fh e en n 12 2 6 Staff Collimation and FOCUS ess 12 2 7 Surveying INOfe i ec QN rr ndi 13 i MEASURE 1 herein Cei tv rte epist ri Ts 14 3 1 Measure MOJE ear Rhe PN aee tr er ae PER RR 14 3 2 S O GH Stake out Ground Height 15 3 3 S O HD Stake out Height Difference 16 3 4 S O Dist Stake out Distance 17 3 5rEeveling az ON QN oro rr te ERR t e ER TR RR 18 SO GH OED tia ive MEET 20 A ADJUST iem deo a NOT ia ree E E BER Eee eere E HER RR lve ker E ER 22 5 PARAMETER SETWNG SM crore ne e Ee RR EGRE SPERA RUE Qo dp eaten 24 6e DATA MANAGE ica cir nen ee EGER Ri n E EC Re EE CERE a 25 7 OTHER FUNCTIONS eese nennen nnne nnne nennen nnn nnn 26 7 1 Distance Display DIST seeeen nn 26
3. and the graduation increases from 0 to 350 in clockwise direction 1 First set up and level the instrument in start point C Second sight the telescope to backsight point A and rotate the horizontal tangent screw until crosshair is accurately on the staff at point A Rotate the horizontal dial at O 2 Sight the telescope to point B and adjust the horizontal tangent until the crosshair is accurately on the staff at point B And the angle reading is angle between target A and target B i e ZACB point A point B Uu 0 350 4D 30 2t poil point A point B horizontal dial 30 7 4 Optical Distance Measure With the stadia hair of the instrument and the graduation on the staff you can measure the distance easily The stadia interval on the staff multiplies 100 is the distance The stadia interval is the interval between the upper hair and the lower hair on the reticle 1 Set up the staff on the target point 2 Set up and level the instrument Sight the telescope to the staff Record the stadia interval between upper hair and lower wire as 1 3 The distance L between instrument and staff is L 100x1 C stadia hairs 3 N L 1dd x1 26 8 BATTERY AND CHARGER The on board battery is B 21 Charging 1 The output voltage of the charger is AC110V 220V The electric current is 450mA 2 Red light means the battery is being charged Green light means charging is finished 3 It w
4. 13 14 15 16 17 18 battery rough collimator LCD display keyboard panel keys eyepieces use for adjusting the definition of the crosshair protecting cover of eyepieces by releasing this cover you can implement the mechanical adjustment of the reticle in order to correct the optical collimation line error data transfer port connecting with PDA or computer reflector of circular vial circular vial triorach lifting handle model label objective lens focusing hand wheel use for focusing of digital staff power measure key use for instrument power ON OFF and measure horizontal tangent hand wheel horizontal dial use for setting the horizontal direction value of the collimating direction to O or other required values 19 leveling screws of the tribrach 1 2 Operation Keys amp Functions key O name function Power ON OFF Power ON OFF and start to measure Power OFF hold on for 2 seconds measure the distance and display the distance m number moving Turn the left or right page when viewing the data or move left or right in inputting status key To confirm the parameters or inputting data ESC ESC To escape from menu mode or any setting mode Also to go backspace to delete a character in inputting mode inputting numbers Mode of setting Use for inputting inverse staff Set the inverse inverse staff staff You should activate this function in parameter setting first dS ouminaton
5. train or ship transportation the instrument should be stored in original carrying case and carton 4 Delivering the battery related law and rules should be totally understood Inform the carrier before the shipment 27 Storage 1 Notice the temperature when storing the instrument especialy the temperature inside the car in hot sumrner 2 The battery should be removed if the instrument is going to be stored for a long time 3 Do not store the wet instrument into the case before it is wiped ary Clean 1 Clean the instrument after use a If the instrument is wet by seawater it should be wiped with a wet cloth and then be dried by a dry cloth b Wipe the dust on the instrument with a clean brush and a soft cloth Do not blow it with compressed air c Wipe the dust on the objective lens with a clean brush and wipe it with cotton with mixture of alcohol and aether 2 When cleaning the plastic parts of the instrument do not use volatile liquid Such as thinner and benzene Neutral cleansing is suggested 3 Clean the staff after use otherwise it will influence the accuracy Do not use volatile liquid such as thinner and benzene to clean the staff 4 Store the staff in safe place It is suggested to cover the joints of the staff with a cloth 28 11 SPECIFICATION nie QE eee digital reading 1 5mm standard deviation for 1km double run leveling optic reading 2 0mm digital reading D lt 10m 10mm D gt 10m
6. D 0 001 digital reading 1 5m 100m Lry HD Imm 0 5mm w ee eee minimum display 0 1 lom measuring time within 3s in normal condition felescope field of view multi constant add constant magnetic damped compensator 0 50 1 16MB data storage auopowerof 5miute OFF display LCD display ofl 28 32dpi with illuminator temperature 2 dimension 230 0x150 W x210mrtHj weight 2 5kg 29
7. GH amp HD i 3 Input the job name and press ENT Input job Job Name a name 2 ENT L54 4 Input the point number of backsight Input point BS PN oint and press ENT number gt p p ENT P1 5 Select whether to use the existed ENT Load data data Y ENT N ESC ENT T01 T02 ENT G H 30 00m MERSI Y ENT N ESC 6 Collimate the staff ntil it looks clear and press MEAS Meas the BS Pt PN P1 7 It displays the backsight staff and the distance Press MEAS to measure continuously or press ENT to measure next point BRod 1 2125m BDist 8 575m lt 8 Press gt or 4 to choose to l ENT SelectPtType measure FS frontsight point or FS Int intermediate point Int Pt Now choose FS first Input point 18 number FS PN 9 Input the point number of frontsight gt P2_ point and press ENT ENT Meas the FS Pt 10 Collimate the staff until it is clear PN P2 and press MEAS MEAS FRod 0 9550m FDist 8 486m gt or lt ENT 11 Press gt or 4 to choose to SelectPtType measure BS backsight point or Int BS gt Int Intermediate point Now choose nput point intermediate point number 2 ENT 12 Input the point number of the IntPt Int Pn and press ENT IMEKS gt 12 13 Collimate the staff until the staff is Meas the Int Pt clear and press MEAS PN 11 IRod 0 7395m IDist 8 501m 14 Press ESC and ENT
8. Press ENT to display the height and the value to fill or dig means to fill and means to dig GH 1 0300m HD 3 9705m 9 Press ENT to continue to stake out ENT Continue or press ESC to quit ESC New Meas 16 3 4 S O Dist Stake out Distance User can stake out by inputting the distance Operation Procedure Display 1 Press ENT ENT Menu gt 1 Measure l 2 Press A or V to select S O Dist ENT 1 Measure Mode li stake out distance and press ENT gt 2 Stake out Y ENT 3 S O Dist J 3 Input the distance of stake out point Mos the Input Dist i and press ENT istance 50 press LENT ENT m 4 Collimate the staff until it looks clear S O Dist a and press MEAS MEAS Press MEAS 5 Displays the distance and the difference Press MEAS to measure ENT Dist 30 00m continuously or press ENT to go to ARod 20 00m next step or press ESC to quit When the ARod is positive itiindicates ENT Continue L to move the staff backward When the ESC New Meas ARod is negative it indicates to move the staff forward 17 3 5 Leveling In Leveling mode the saving mode should be set to Auto or Manual save In this session we set it Auto Save Operation Procedure Display 1 Press ENT Menu B gt 1 Measure l 2 Press A or V to select Leveling V 1 Measure Mode ff and press ENT gt 2 Stake out i ENT gt 3 Leveling a 4
9. Turn ON OFF the illumination decimal point Inputting a decimal point 1 3 Display The display adopts dot matrix LCD displaying 2 lines with 16 characters in each LCD illumination ON OFF By pressing 8 t6 turn ON or OFF the illumination It is also available to set it in instrument parameters Setting Contrast There re 9 degrees for the contrast Please refer to parameter setting to know how to set the contrast 2 PREPARATION FOR MEASUREMENT 2 1 Mounting the Instrument Placing the Tripod Type E aluminurm tripod with flat or dome head tripod is required 1 Adjust the three legs of the tripod to a proper length and tighten the fixing screws at the middle of the leg 2 Tighten the hexagonal nut on the head of the tripod in order to make the tripod legs not too loosen Place the tripod on a certain point expand the legs until the distance between each leg is about Im First fix a leg and move the other 2 legs to make the head of the tripod approximately leveled If necessary adjust the length of the tripod legs 3 Trample the legs into the earth or fix it well on the ground Putting the Instrument on the Head of the Tripod Take out the instrument from the case carefully and place it on the head of the tripod 1 Aim the tripod central screw to the center of the tribrach center and tighten the screw until it is fixed at the head of the tripod 2 If you need to define an angle or a line through the horizo
10. and press ENT gt 2 Stake out 3 Leveling gt 4 GH amp HD 20 3 Press ENT to save the data ENT Input job 4 Input the job name and press ENT name ENT 5 Input the GH ground height of the ENT backsight point Input point number ENT 6 Collimate the staff until it looks clear and press MEAS MEAS 7 It displays the backsight rod reading and the distance Press MEAS to measure continuously or press ENT to MEAS measure next point 8 Collimate the staff on the front sight point until it looks clear and press MEAS 9 It displays the frontsight rod reading and the its ground height and height difference 10 Press ESC to restart the measurement 21 Save Data Y ENT N ESC Job Name gt H5_ Input BS GH Y ENT N ESC BS GH 2168 680m Meas BS Pt Press MEAS BRod 0 841m BDist 10 005m Meas FS Pt Press MEAS FRod 0 841m FDist 10 005m GH 168 479m HD Exit Y ENT 0 001m N ESC 4 ADJUST Inspection of the collimating sight line i angle of the instrument 1 As Picture 1 displays mount the instrument on a tripod between 2 staff which is 50m away from each other Divide the distance between A and B into 3 sessions with the same distance 2 Level the instrument b Ib a B5 if 163 1 1 3 n A63 14 about 50m retide adjusting screw 1 Select Adjust in the menu and Aor Y press ENT ENT g
11. to quit ENT Continue ESC New Meas After measurement below data will be displayed After measuring the backsight point press A or W to show the following screen BRod 1 022m Measurement value of backsight point BDist 15 07m GH 21 555m L Ground height of backsight point PN P01 Point number of backsight point When the current measurement finishes press A or Y to display the following Screen 19 FRod 1 032m Measurement value of front sight point FDist 15 07m GH 22555m B Ground height of front sight point PN P05 Point number of front sight point HD 0 532m Height distance of this station gt 25 003m Total length When the measurement of interval point is finished press A or Y to display the following screen IRod 1 022m Measurement value of intermediate IDist 15 07m point point Ground height of intermediate point GH 21 555m Point number of intermediate point PN P01 Explanation about the middle point number of leveling measurement Before frontsight measurement you can change the point number It starts with P and 5 numbers following Which will be increased Those point numbers that are used can be used again 3 6 GH amp HD This mode can measure the GH ground height or HD height difference of the backsight point before measurement Operation Procedure 1 Press ENT ENT Apis s Measure 2 Press A or V to select GH amp HD V 1 Measure Mode li
12. 40m It displays the stakeout rod reading and SDist 7 633m the distance Press ENT to display the height and the value to fill or dig means to fill and means to dig GH 1 0300m HD 3 9705m 9 Press ENT to continue to stake out ENT Continue or press ESC to quit ESC New Meas 15 3 3 S O HD Stake out Height Difference User can stake out by inputting the HDs height differences of the backsight point and the stakeout point Operation Procedure Display 1 Press ENT ENT heey a gt 1 Measure l 2 Press A or V to select layout ENT 1 Measure Mode amp and press ENT gt 2 Stake out l 3 Select Margin Out and press ENT ENT 1 8 0 GH i 2 5 0 HD 4 Input the GH ground height of Input BS BS GH backsight point and press ENT height 100 ENT 5 Input the HD height difference of Input VH SO HD the stakeout point and press ENT of stakeout E point ENT Il 6 Collimate the staff until it looks_clear Meas BS Pt and press MEAS MEAS Press MEAS 7 It displays the backsight rod reading and the distance Press MEAS to BRod 0 8050m measure continuously or press ENT to BDist 8 550m go to next step or press ESC to quit MEAS Meas SO Pt Press MEAS 8 Collimate the staff on stakeout point until it looks clear and press MEAS or ENT or SRod 0 6540m It displays the stakeout rod reading and ESC SDist 7 633m the distance
13. 7 2 Inverse Staff Mode eeeeeeeeeeenns 26 7 3 Horizontal Angle Measurement sss 26 7 4 Optical Distance Meoasure sseeee mmn 26 8 BATTERY AND CHARGER can cinin a EA rin te re E RR RR erre ERR ERR 27 9 CIRCULAR VIAE ADJUSTMENT isi ron t tt n een uri ect na 27 10 TRANSPORTATION STORING AND CLEANING eee 27 VEZSPEGIRIGATION 555 tierra et pterea eere ti ed eei cue Penta eati 29 FOREWORDS Congratulations on your purchasing the Digital Level DL 202 In order to operate this instrument correctly please read this user manual carefully and keep it well so as to refer to it easily in the future Before use please check the standard features and make sure all the equipments and accessories are available In order to facilitate reading some pictures are simplified PRECAUTIONS Before using this instrument please make sure that each function is running well Avoid to make the surface of the digital staff as well as the joints between each section dirty or damaged otherwise it will influence the accuracy of reading and measurement This is because the instrument needs to transfer ihe black amp white bar code to electric signal That s why in case the digital staff is dirty the accuracy would be decreased or even the instrument is not able to measure Tripod The digital level should be mounted on wooden tripod Metal tripod is lighter and it s easy to shake which will affect the acc
14. ase change anther battery or charge the battery unable to measure The power will be cut off soon You need to change the battery 2 4 Setting the Data Save Mode In order to save the measurement data into the internal memory of the instrument before leveling measurement the data saving mode should be set to auto save as the default setting is OFF 2 5 Main Menu Meu 29Meu 3 Meu 4 Meu Meosue Mode Mode ideis Stake out comp SQos 5 veing TAO GH amp HD 2 1 N Times Meus Para Min Reading 1 mm 0 5mm Not Use Use Display Unit m meter ft US Ft OFF Auto Manual save Auto OFF On Off Controst PO Ins Para Backlight Off On sino Regis Info esn Loo mcm PN search PN StdMeasData LvMeasData GH HD Data Input PN StdMeasData Data Manage sli idea LvMeasData GH HD Data Check Capa J Input PN StdMeasData ele Oulu LvMeasData GH HD Data 2 6 Staff Collimation and Focus 1 Focusing Adjust the eyepiece focusing screw until the crosshair can be seen clearly Then adjust the focusing screw until you can see the staff clearly through the objective lens 12 A precise focusing can shorten the measuring time and improve the accuracy Measurement of high accuracy requests precise focusing as well as continuous measures 2 Obstacles Measurement can be implemented if the staff is blocked less than 30 Even if the crosshair center is blocked as long a
15. ay error or the accuracy is influenced 4 If an error occurs because the place where the staff is put is darker than that of the eyepiece you are suggested to block the light for the eyepiece 5 Deflection and pitching of the staff may affect the accuracy During the measurement make sure the staff is paralleled to the vertical hair of the reticle The staff should be unfolded completely and fixed well Make sure the joints of the staff are well and precise Avoid to measure through the glass window 6 After a long storage or transportation check and calibrate the digital and optical sight errors Then adjust the circular vial and keep the optical parts clean 13 3 MEASURE 3 1 Measure Mode This mode is to measure the staff reading and distance without calculating the height Refer to Set to set the measure times Using the average value upon several times can improve the accuracy Operation Procedure 1 Press ENT 2 Press A or V to select the Measure Mode and press ENT 3 If the saving mode is set to Auto save or Manual save 4 Input the job name and press ENT 5 Collimate the staff until it looks clear and press MEAS to measure The last value after several measures is the average value Under continuous measure press ESC to stop and record 6 Press A V to view the point After saving the point number wil be increased automatically 7 Press ENT to confirm or ESC to quit
16. bubble by adjusting the tribrach screw First put the tribrach as the below picture shown Rotate 2 screws at the same time in opposite direction until the bubble moves to a position where the line between 10 the bubble and screw C is perpendicular to the line between screw A and B refer to Picture A Then rotate the screw C to move the bubble to the center of the central circle This procedure should be repeated for times until the bubble is centered on any directions Picture A Picture B Notice Do not touch the telescope during leveling Collimating and Focusing 1 Sight at the digital staff with the rough collimator 2 Rotate the eyepiece slowly until the image of the crosshair becomes clear 3 Rotate the focusing hand wheel until the image of digital staff becomes clear Rotate the horizontal tangent to move the image of the staff to the center of the vertical hair of the crosshair 4 Observe through the eyepiece Move your eye slightly up down left and right to check whether the relative position between the crosshair and the image of the staff isnot changed If not please return to step 1 Notice Measurement accuracy may be influenced if the crosshair and focusing is not clear 2 2 Power On Press the power key POW MEAS 2 3 Remaining Battery Display The battery symbol indicates the remaining battery battery quse Menu 9 1 Measure B full E sufficient 11 a half battery low Ple
17. for protection e g safety shoes safety helmet Do not place the instrument directly on the ground If the operator has to leave the instrument alone please cover the instrument with a nylon cover if available DECLARATION OF EXCEPTIONAL RESPONSIBILITY Users of this product should read the user manual thoroughly and implement periodical inspection to the performance of the instrument e Manufacturer and its dealers shall not be responsible for any direct or indirect consequences and profit loss resulted from destructive or intentional improper use e Manufacturer and its dealers shall not oe responsible for any direct or indirect consequences and profit loss resultedyfrom natural calamities e g earthquake hurricane flood etcs ire accidents or fault of a third party e Manufacturer and its dealers shall not be responsible for failure to operate resulted from the fact that the data is changed or lost or that operation is interfered e Manufacturer and its dealers shall not be responsible for any consequences and profit loss resulted from extra use without following the user manual e Manufacturer and its dealers shall not be responsible for any consequences and profit loss resulted from improper transportation or connecting with other products 1 NAME OF EACH COMPONENT amp ITS FUNCTION 1 1 Name of Each Component m 5 gt i 1l a Nc Vaz 2 SS r 2 11 O01 CP 8 9 10 11 12
18. ght to search for the base point in leveling measurement Search User can search for input point standard measurement data leveling measurement data and GH HD data Delete Job User can delete input point standard measurement data leveling measurement data and GH HD data Check Capa User can check the capacity of the internal memory File Output User can export the input point standard measurement dota leveling measurement data and GH HD data to the computer Baud rate 9600 data length 8 stop 1 no parity According to file types user can add the extension following the rules below L leveling data M measurement data H GH HD data input point data Format User can format the internal memory 25 7 OTHER FUNCTIONS 7 1 Distance Display DIST Use the DIST to measure the distance before surveying to make sure the distances between the frontsight and backsight are same 7 2 Inverse Staff Mode Under this model staff can be inverted for the ceiling measure Firstly set the Inverse Mode to Use in the Meas Para setting Before pressing MEAS press the button The battery symbol and symbol I will appear alternately on the upper right corner of the screen That means the Inverse Mode is activated 7 3 Horizontal Angle Measurement This instrument is equipped with a horizontal dial which can be used for horizontal angle measurement Every 1 with a graduation every 10 with a mark in the dial
19. ill take 5 hours to charge the battery Note a Charging should be in a temperature of 10 C 40 C b When the charging time exceeds the suggested charging time the battery life might be shortened C The battery may discharge in storage Inspect the battery before use if the instrument is stored for a long time d The battery should be stored in a temperature below 30 C and should be recharged every three or four months 9 CIRCULAR VIAL ADJUSTMENT 1 Mount the instrument on a tripod Center the circular vial precisely by rotating the 3 tribrach screws 2 Rotate the instrument 180 If the bubble is not in the center the circular vial should be calibrated as follow a Firstly identify the bubble moving direction and adjust the corresponding screws to move the bubble half of the offset b Level the circular vial with the 3 tribrach screws again C rotate the instrument around again to check whether the bubble is centered in every direction If not please repeat the steps a amp b until the bubble is centered 10 TRANSPORTATION STORING AND CLEANING Transportation 1 In outdoor operation the instrument should be stored in the carrying case or fixed on the tripod and carried on the shoulder Make sure not to carry the instrument upside down 2 In road transportation do not leave too much space between instrument cases Normally the instrument should be stored in a special case in road transportation 3 In plane
20. n case of explosion do not place the instrument close to inflammable gas liquid or solid Do not operate it in coal mine or dusty place Do not disassemble or repair the instrument without authorization in case of possible dangers occurred like fire electric shock or damage Disassembling and maintenance are only implemented by the manufacturer and its authorized service providers Do not use the telescope to sight at the sun or sunlight that are refracted by reflectors like prisms in case of any hurt to the eyes Be careful to operate the instrument with the digital staff near high voltage cables or transformers in case of electric shock accident Do not use the digital staff when there are thunder and lightning in case of electric shock Do not use chargers and batteries that are produced by a third party in case of fire Do not use a broken power supply wires sockets and plugs in case of fire or electric shock Do not use humid batteries or chargers in case of fire or electric shock Do not place the batteries in fire or high temperature environment in case of explosion or damage Do not use the power supply mentioned in the manuals of non manufacturers in case of fire or electric shock Avoid short circuit when storing the batteries in case of fire Do not disassemble or assemble the instrument or operate the plug with wet hands in case of electric shock Do not cover the charger when it is charging in case of fi
21. ntal dial you should center the instrument precisely witha plummet 3 Center the circular bubble by adjusting the three leveling screws of the tribrach If you are using a dome headed tripod you should slightly loosen the tripod central screw and rotate the instrument round the head of the tripod until the circular bubble is centered then tighten the screw Mounting the Instrument on a Certain Point centering If you need to measure an angle or alignment please precisely center the instrument at a certain point witho plummet 1 Hang the plummet at the plummet hook of the central screw of the tripod 2 Adjust the plummet line to a proper height 3 In case the instrument is not centered at the known point you can move the instrument to that point without changing the position relationship between the tripod leg and its head First put the tripod on the known point approximately until the plummet is about 1cm away from the point Second grasp two legs of the tripod and adjust the tripod by the third leg until the head of tripod is leveled approximately with a proper height Expand the legs of the tripod and fix it on the ground 4 Finally observe the plummet and the hook and trample the legs into the ground 5 Slightly loosen the central screw of the tripod and move the instrument on ihe head until the plummet is centered at the known point Tighten the tripod central screw Leveling the Instrument Center the circular
22. re Do not touch the liquid leaked from the battery in case of hurt by the harmful chemicals And please change the battery Injury to persons or damage to goods may occur if the following cautions are not followed by operators Harm means hurt burn electric shock etc Damage means serious damage caused to building instrument or furniture Overtuming the instrument case may damage the instrument Do not stand or sit on the case Do not use the instrument case with broken belt buckle hinge or lifting handle in case that the instrument is damaged or it hurts the legs if the case falls e When mounting or delivering the instrument please be careful that the leg tips of the tripod may hurt people Qe Please make sure to mount the tribrach correctly Serious damage will occur if the tribrach falls from the tripod e When mounting the instrument on the tripod make sure the central fixing Screw is tightened well to prevent the instrument from falling from the tripod e When mounting the instrument make sure the screws of the tripod are tightened well e When moving the tripod make sure the screws of the tripod are tightened well OPERATOR This instrument is only operated by specific persons It is required that the operator should be a qualified surveyor Before operation inspection and calibration operators should be acknowledged the safety guide During using the instrument please wear necessary suits
23. s the field of view is blocked less than 30 measurement still can be implemented However in this case the accuracy might be affected 3 Shadow The surveying accuracy may be influenced if the staff is covered by shadow In some cases it is not possible to measure 4 Backlight If the background of the staff is too bright which affects the contrast of the staff the digital level might not be able to measure You can cover something ahead of The objective lens in order to reduce the background light invading to the lens When a strong light comes into the eyepiece it might not be able to measure either You can also cover the eyepiece in order to block the strong light from coming into the eyepiece When the sun is in a low position for example in th morning or at night fall or if the sun light comes into the objective lens directly it is suggested to block the sunlight with hands 2 7 Surveying Note In order to make full use ofthe functions of instrument please pay attention to the following 1 Set up the staff in bright place If possible prolong the staff completely If illumination is employed it is suggested to illuminate the whole staff otherwise the accuracy might be affected 2 The shortest distance between instrument and staff is 1 5m 3 It won t affect the digital level to measure if the staff is blocked But if the bar code on the staff is blocked by tree branches or leaves the digital level might displ
24. t 1 Measure gt 2 Adjust 2 Press MEAS MEAS 3 Press ENT ENT 4 Press MEAS 22 5 Press ENT Abd 023m You can power off the instrument and move it 6 Press MEAS MES 7 Press ENT LENT 8 Press MEAS 9 Press ENT ENT Boda A lor V 0 0000m 10 Press A or V and ENT ENT 0 0 0000m 11 Press ENT ENT 0 23 5 PARAMETER SETTING N Times Continuous Min Reading Imm 0 5mm Meas Para verse Not Use Use Mode Display Unit m meter ft US ft OFF Auto Manual save Ins Pora Resmo id Setting the measuring times of average measurement Operation Procedure 1 Press A or V and ENT to select A or V Menu Set ENT gt 1 Measure 2 Adjust p 3 Set gt Meas Para Ins Para Press ENT ENT gt 1 Meas Mode 2 Min Reading Press A d ENT AJorY i ress A or Y and ENT ENT 1 N Times 2 Continuous Press ENT ENT Meas Times N 1 1 9 Press times Meas Times ENT N 5 1 9 Input the times and press ENT 24 6 DATA MANAGE Operation Procedure Display 1 Press A or Y to Data Manage A or V Menu H ENT gt 1 Measure l gt 4 Data Manage 2 Press ENT ENT gt 1 Input PN 3 Press A or V and ENT to select A or V 2 Search ENT gt 3 Delete Job 4 Check Capa gt 5 File Output 6 Format Input Pn User can input the point number and _ hei
25. uracy Each leg of the tripod should be fixed well by screws Tribrach In case the tribrach is installed not properly the accuracy would be influenced Please inspect the adjusting screw on the tribrach frequently and make sure the central fixing screw is tigntened e Packing well to avoid the instrument shaked As an precise instrument the digital level should be handled carefully to avoid shaking and crashing during transportation Severe shaking would damage the measurement functions When packing the instrument in the case make sure it is powered off and take off the battery Carry the instrument carefully When you need to move the instrument you must grasp the lifting handle and take it off from the tripod Avoid to expose the instrument in sun rain or humid condition Leaving the instrument in place of high temperature 50 C would damage ihe instrument Do not shoot the sun with the objective lens otherwise the spare parts inside the instrument may be damaged G void a great change on temperature A great change on instrument temperature would decrease the measuring range For example when the instrument is moved out from a hot car please leave the instrument to adapt to the surrounding temperature before use Battery Inspection Check the remaining battery before use Digital Staff Wear a glove when using a digital staff SAFETY GUIDE Serious injury or even death may occur if the following cautions are ignored e