Home

NI PXIe-4322 and TB-4322 Installation Guide and Terminal Block

image

Contents

1. Qy NATIONAL gt INSTRUMENTS Contents What You Need to Get Started ccc eeeseseesceecseeecseceesecsesenseceesecsesevsesaesessceavaceeseeeeceeseseeeness 2 1 EKSTE lations scot rane atcha be te ANE tat Bete E E E teh Soe Install the Software Unpack and Install the Module Connect the Signals 0 0 0 0 Install the Terminal Bock scoici niii ra ar Confirm NI SC Express Module Recognition cccecesescsceeceessesesseseseeeseseeeeseeeeecnenees 9 Rut Pest Panels eeirwvesteeest cece Sateen E eae asa neces oy eA A ate 10 Generate an NI DAQmxX Signal cece scceeeseseeseceeeseeerscseseeecsaeseeecnececeecneeensesaeesaenenees 11 Use Your NI SC Express in an Application essessessessesesssseeessesesseeestsessesessserstserssesessene 11 Terminal Block Removyal sseeseeeeseeeeeeesrerereeeee Module Removal eee 7 Cr atea simulated Devices tt Aes Se eS Rie tte Oe Ri nes oo Mor Tnformati onin enric sab cates oi seca E duc coe dee otek cates EAA E E Troubleshooting sc 0 ci cascssnccssvsereavis setvi cateesesnesseanasv dveancansaveancatesrsavesvssneecedeiberpecndrpesnensessays Specifications TB 4322 ccccccesccecceseastesedsecasceecdacescuncuscuvceschucences cesses ces descesdeddectascascasdaveassnestcve Calibration Interval Electrical Mechanical a PhiysiCal ves S203 clic souls tues area E a ae EENES Environmental Specifications ccceesesesceseseeeceeceeeecseceseecsesesscsaesessceeeecsa
2. DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our Environmental Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE K EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Aaa anise hl BED CHE ROHS QO RAA National Instruments 46 p E E TAE A m PBR HI EF SE ROHS XF National Instruments FE ROHS AARETE WK ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china Where to Go for Support The Natio
3. an example NI SC Express system setup Figure 6 Sample NI SC Express System 1 Terminal Block 2 Signal Output Confirm NI SC Express Module Recognition To confirm module recognition complete the following steps AEN Note Make sure you are using the most recent version of NI DAQmx If you are using an older version of the driver software the NI SC Express terminal block may work only in basic functionality mode Unsupported terminal blocks appear in Measurement amp Automation Explorer MAX with an X next to them 1 Launch MAX t 2 Expand Devices and Interfaces and expand NI DAQmx Devices to confirm that MAX detects the module and terminal block The terminal block should appear beneath its associated module If your module or terminal block is not listed press lt F5 gt to refresh MAX If the module is still not recognized go to ni com support daqmx NI PXle 4322 and TB 4322 Installation Guide National Instruments 9 TB 4322 Measurement amp Automation Explorer File Edit View Tools Help 4 Q My System X Delete H3 Accessc E Data Neighborhood a g Devices and Interfaces Name a 2 NIPXle 4322 PXI Slot2 El Serial Number a TB 4322 E Connector Number a Network Devices LY Serial amp Parallel 42 Scales E Software Q Tip Using an NI DAQmx simulated device you can test NI DAQmx applications without installing hardware Refer to the Create a Simulated Dev
4. 2 Module 1 Mounting Screw 3 NI PXle Controller 5 TB 4322 Terminal Block 2 Latch Release 4 NI PXle Chassis 3 Store the terminal block in an antistatic protective bag 12 nicom NI PXle 4322 and TB 4322 Installation Guide Module Removal A Caution Do not remove a module with the power on Doing so can damage the module 1 Make sure that the chassis is powered off before removing the module 2 Loosen the captive screws on the top and bottom of the module A Caution Do not pull the front panel to remove the module Doing so may cause module components to come into contact with adjacent modules causing damage to the modules 3 Pull the captive screws to unseat the module and slowly slide the module along the guides as shown in Figure 8 4 Replace the filler panel in the empty slot Store the module in an antistatic protective bag Figure 8 Removing NI SC Express Modules 1 Captive Screws Use to remove modules 2 Front Panel Do not use to remove modules NI PXle 4322 and TB 4322 Installation Guide National Instruments 13 Create a Simulated Device To run examples without the hardware installed use an NI DAQmx simulated device To create a simulated device in MAX complete the following steps 1 Launch MAX Right click Devices and Interfaces Create New From the dialog select Simulated NI DAQm x Device or Modular Instrument Type 4322 in the text box at the top of t
5. INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXle 4322 and TB 4322 Fran ais Deutsch H R s0 AFX ni com manuals NISC Express is a family of PXI Express modules with integrated data acquisition and signal conditioning These devices offer increased speed accuracy and synchronization features that are well suited for high density sensor measurement and signal conditioning systems Accessories required for signal connections to these modules include a front mount terminal block with screw terminal connectivity This guide describes how to install and configure the NI SC Express PXIe 4322 module and terminal block connect signals and verify that the system is working properly Current versions of NI documents are available at ni com manuals The NI PXIe 4322 is an isolated eight channel analog output module and is designed for use with the TB 4322 terminal block The keying of this terminal block prevents it from connecting to other modules that could be damaged by the voltage present on the terminal block However you should only use this terminal block with its supported modules A Caution When hazardous voltages gt 30 Vims 42 4 V px 60 VDC are present on any terminal safety low voltage lt 30 Vims 42 4 V pk 60 VDC cannot be connected to any other terminal A Caution Do not supply hazardous voltages gt 30 V ms 42 4 Vpx 60 VDC to the terminal block without the terminal block being connected to the NI PXIe 4322
6. RF 28800F Class 2 limits 5 Hz to 500 Hz 0 3 gims 5 Hz to 500 Hz 2 4 gins Tested in accordance with IEC 60068 2 64 Non operating test profile exceeds the requirements of MIL PRF 28800F Class 3 Connect only voltages that are within the following limits Between any two AO and AO pair Isolation Voltages Channel to channel Withstand Channel to earth ground Withstand Measurement Category II is for measurements 120 VDC 300 Vims Measurement Category II Basic 1 500 Vims performed on circuits directly connected to the electrical distribution system This category refers to local level electrical distribution such as that provided by a standard wall outlet for example 115 V for U S or 230 V for Europe A A Measurement Categories III or IV Caution Do not connect the TB 4322 to signals or use for measurements within Caution The protection provided by the TB 4322 can be impaired if it is used in a manner not described in this document 16 nicom NI PXle 4322 and TB 4322 Installation Guide Safety Standards This product meets the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use e TEC 61010 1 EN 61010 1 e UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or the Online Product Certification section Electromagnetic Compatibility This product me
7. Reinstall the strain relief bar and tighten the strain relief screws 10 Use tie wraps to connect the signal wires to the tie wrap holes for additional strain relief when necessary 11 Reinstall the top cover and tighten the captive top cover screws Note For information about sensors go to ni com sensors NI PXle 4322 and TB 4322 Installation Guide National Instruments 7 Install the Terminal Block Refer to Figure 5 to install the terminal block on the module while completing the following steps 1 Move the TB 4322 into position in front of the NI PXIe 4322 and engage the alignment feature with the guide on the associated module Figure 5 Installing the TB 4322 on the NI PXle 4322 Module 1 NI PXle Controller 3 Mounting Screw 5 NI PXle 4322 Module 2 NI PXle Chassis 4 TB 4322 Terminal Block 6 Alignment Feature 2 Attach the TB 4322 to the NI PXIe 4322 module by pushing the terminal block straight into the module A spring mechanism will lock in the bottom of the terminal block 3 Tighten the mounting screw at the top of the TB 4322 to attach it to the NI PXIe 4322 module EN Note For safety purposes and to prevent damage to equipment when high voltages are present all NI SC Express modules and terminal blocks are keyed to prevent connection between incompatible terminal blocks modules and or cables 4 Power on the chassis 8 nicom NI PXle 4322 and TB 4322 Installation Guide Figure 6 shows
8. al notices in the readme file for your NI product Refer to the Export Compliance Information at ni com 1legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data 2013 National Instruments All rights reserved 375957A 01 Apr13
9. ets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use e EN 61326 1 IEC 61326 1 Class A emissions Basic immunity e EN 55011 CISPR 11 Group 1 Class A emissions e EN 55022 CISPR 22 Class A emissions EN 55024 CISPR 24 Immunity e AS NZS CISPR 11 Group 1 Class A emissions e AS NZS CISPR 22 Class A emissions e FCC 47 CFR Part 15B Class A emissions e ICES 001 Class A emissions A Note Inthe United States per FCC 47 CFR Class A equipment is intended for use in commercial light industrial and heavy industrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection analysis purposes A Note For EMC declarations and certifications and additional information refer to the Online Product Certification section CE Compliance CE This product meets the essential requirements of applicable European Directives as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC NI PXle 4322 and TB 4322 Installation Guide National Instruments 17 Online Product Certification Refer to the product Declaration of Conformity
10. fore connecting or disconnecting signal wires 2 Identify a supported PXI Express slot in the chassis NI SC Express devices can be placed only in PXI Express Peripheral slots PXI Express Hybrid Peripheral slots and PXI Express System Timing slots Refer to the chassis documentation for details Figure 1 Symbols for PXI Express PXI Express Hybrid and PXI Slots PXI Express System Controller Slot 3 PXI Express Hybrid Peripheral Slot 2 PXI Peripheral Slot 4 PXI Express System Timing Slot 3 Remove the filler panel and touch any metal part of the chassis to discharge static electricity 4 Place the module edges into the module guides at the top and bottom of the slot A Caution When installing the module make sure both edges are positioned inside the guides and that the module components do not come into contact with adjacent modules 5 Slide the module along the guides until it reaches the rear connector then seat the module by pushing the front panel until it is flush with the front panel of the chassis 4 nicom NI PXle 4322 and TB 4322 Installation Guide 6 Secure the module to the chassis using the front panel captive screws shown in Figure 2 Tighten the screws to 0 31 N m 2 7 1b gt in Figure 2 Installing NI SC Express Modules 1 Captive Screws Connect the Signals A Caution To ensure the specified EMC performance operate this product only with shie
11. he window Select the device from the list provided Click OK OS Oe Be 1 03 More Information After you install NI DAQmx the NI DAQmx documentation is available from Start All Programs National Instruments NI DAQ Additional resources are online at ni com gettingstarted You can access online device documentation by right clicking your module in MAX and selecting Help Online Device Documentation A browser window opens to ni com manuals with the results of a search for relevant documents If you do not have Web access documents for supported modules are included on the NI DAQmx disc Troubleshooting Go to ni com support install orni com kb e Ifyou need to return your National Instruments hardware for repair or device calibration go toni com info and enter rdsenn to start the Return Merchandise Authorization RMA process Specifications TB 4322 Note NI PXIe 4322 module specifications are located in the NJ PXTe 4322 Specifications document All specifications are typical at 23 C unless otherwise specified Calibration Interval TB 243 22 ASES SENEST ENE OS EEIE EA No calibration Electrical TB 4322 is a feedthrough terminal block For electrical output characteristics refer to the NI PXIe 4322 Specifications document 14 nicom NI PXle 4322 and TB 4322 Installation Guide Mechanical Screw terminal wire gauge cccccseeseeseeseees 16 AWG max Physical Figure 9 TB 4322 Dimensi
12. ice section for instructions for creating NI DAQmx simulated devices 3 Right click the module name and select Self Test When the self test completes a verification message appears If an error occurs refer to ni com support daqmx For information about sensors go to ni com sensors Run Test Panels 1 In MAX expand Devices and Interfaces NI DAQmx Devices 2 Right click the device and select Test Panels a GY 2 NI PXIe 4322 PXI1Slot2 Measurement amp Automation Explorer File Edit View Tools Help 4 My System SF Configure X De E Data Neighborhood 4 ry Devices and Interfaces Name 2 NI PXle 4322 PXI Slot2 El Serial Number at Network Devices Ki Self Test jot Number Serial amp Parallel 5 Test Panels assis Number 44 Scales 5 Name Reset Device 61 Software Version a Remote Systems 0 Create Tack 3 Click Start to test device functions or Help for operating instructions To troubleshoot errors refer to the V DAQmx Help or go to ni com support 10 nicom NI PXle 4322 and TB 4322 Installation Guide Generate an NI DAQm x Signal NI DAQmx Channels and Tasks Refer to the MJ DAQmx Help for complete information about channels and tasks Use the DAQ Assistant to configure virtual channels and tasks in MAX or in your application Configure a Task Using the DAQ Assistant from MAX Complete the following steps to create a task using the DAQ Assistant in MAX In MAX right click Data Ne
13. ighborhood and select Create New to open the DAQ Assistant Select NI DAQmx Task and click Next Select Generate Signals Select analog output and the measurement type such as voltage Select the physical channel s to use and click Next Name the task and click Finish SA a er ae Configure the individual channel settings Each physical channel you assign to a task receives a virtual channel name To modify the output range or other settings select the channel Click Details for physical channel information Configure the timing and triggering for your task Click Run Use Your NI SC Express in an Application For NI software version compatibility refer to the N DAQmx Readme available from Start All Programs National Instruments NI DAQm x To get started with data acquisition in your application software refer to the tutorials listed in Table 1 Table 1 DAQ Assistant Tutorial Locations Application Tutorial Location LabVIEW Go to Help LabVIEW Help Next go to Getting Started with LabVIEW Getting Started with DAQ Taking an NI DAQmx Measurement in LabVIEW LabWindows CV Go to Help Contents Next go to Using LabWindows CVI Data I Acquisition Taking an NI DAQmx Measurement in LabWindows CVI Measurement Go to NI Measurement Studio Help Getting Started with the Measurement Studio Studio Class Libraries Measurement Studio Walkthroughs Walkthrough Creating a Measurement Studio NI DAQmx Applicat
14. ion LabVIEW Go to Help Taking an NI DAQmx Measurement in SignalExpress SignalExpress LabVIEW SignalExpress an easy to use configuration based tool for data logging applications is at Start All Programs National Instruments LabVIEW SignalExpress NI PXle 4322 and TB 4322 Installation Guide National Instruments 11 Programming Examples NI DAQmx includes example programs to help you get started developing an application LabVIEW and CVI examples are located at Help Find Examples in your application software Text based code examples are located at All Programs National Instruments NI DAQ Text Based Code Support ANSI C Examples Modify example code and save it in an application or use examples to develop a new application or add example code to an existing application For other examples go to ni com info and enter the Info Code daqgmxexp For additional examples refer to zone ni com Terminal Block Removal To remove the terminal block refer to Figure 7 while completing the following steps A Note The chassis can be powered on or off when removing the terminal block 1 Loosen the mounting screw located at the top of the terminal block 2 To remove the terminal block a Raise the latch release using a flathead screwdriver to disengage the latch b With the latch release raised grasp the terminal block and pull it away from the module Figure 7 Removing the TB 4322 from the NI PXle 432
15. lded twisted pair cables and shielded accessories A Caution To ensure the specified EMC performance the length of all I O cables must be no longer than 30 m 100 ft Note Refer to the Read Me First Safety and Electromagnetic Compatibility document before removing equipment covers or connecting or disconnecting any signal wires To connect signals to the terminal block refer to Figures 3 and 4 while completing the following steps Note You can find the pinout names and locations in MAX at any time by right clicking the device name under Devices and Interfaces and selecting Device Pinouts 1 Loosen the captive top cover screws and remove the top cover 2 Loosen the strain relief screws and remove the strain relief bar NI PXle 4322 and TB 4322 Installation Guide National Instruments 5 Prepare the shielded twisted pair cable by stripping the insulation and shield s to expose sufficient signal wire to connect from just inside the strain relief bar to the desired screw terminal Ensure that the drain wire of the shielded cable is long enough to connect to one of the two ground lugs inside the terminal block which are shown in Figure 3 4 Prepare the signal wire by stripping the insulation no more than 7 mm 0 28 in Run the shielded twisted pair cable through the strain relief opening Figure 3 TB 4322 Parts Locator Diagram 1 Strain Relief Screws 4 Ground Lugs 7 Top Cover 2 Strain Relief Bar 5 Terminal Bl
16. ll the Software A Note You must be an administrator to install NI software and devices on your computer Before installing the NI SC Express hardware make sure the following are installed in the order indicated 1 Your application software such as LabVIEW LabWindows CVI or NET 2 NI DAQmx 9 7 or later A Note When installing NI application software such as NI LabVIEW refer to the NI DAQmx Readme on the software disc for supported software versions Back up any applications before upgrading software or modifying the application Q Tip Using an NI DAQmx simulated device you can test NI DAQmx applications without installing hardware Refer to the Create a Simulated Device section for instructions for creating NI DAQmx simulated devices NI PXle 4322 and TB 4322 Installation Guide National Instruments 3 Unpack and Install the Module Remove the packaging and inspect the module Contact NI if the module is damaged Do not install a damaged module A Caution The module is static sensitive Always properly ground yourself and the equipment when handling or connecting to the module Complete the following steps to install the NI SC Express module while referring to Figures 1 and 2 1 Power off the NI PXI Express chassis Refer to the chassis manual for chassis installation and configuration instructions Caution Refer to the Read Me First Safety and Electromagnetic Compatibility included with your module be
17. nal Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request atni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office Web sites which provide up to date contact information support phone numbers email addresses and current events 18 nicom NI PXle 4322 and TB 4322 Installation Guide Refer to the M Trademarks and Logo Guidelines at ni com trademarks for more information on National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find information about end user license agreements EULAs and third party leg
18. ock to Module Connector 8 Tie Wraps 3 Tie Wrap Holes 6 Captive Top Cover Screws 9 Signal Wires 6 6 Insert the stripped end of the signal wires fully into the appropriate terminal Refer to the label next to each screw terminal to determine the function of the terminal The NI PXTe 4322 User Manual provides detailed wiring information Make sure no exposed wire extends past the screw terminal Exposed wire increases the risk of a short circuit that can cause circuit failure ni ccom NI PXle 4322 and TB 4322 Installation Guide Figure 4 TB 4322 Circuit Board Parts Locator Diagram NATIONAL INSTRUMENTS COPYRIGHT 201 o A os oo os oo oo oo oo AS O92 1 1 1 1 EJ 1 1 1 IS fou 52 Feed ba Meel fe 5 co ti STE oe ea eS ee e eeo eso ean H O O Note Refer to the MI PXIe 4322 User Manual for diagrams showing various ways to connect a load to the TB 4322 7 Tighten the terminal screws to a torque of 0 2 to 0 25 N m 1 77 to 2 21 Ib in Caution Any wires connected to the ground must be sufficiently insulated from high voltage 8 Use the ground lugs to attach a shield wire to the ground Attach the drain wire of the shielded cable to a ground lug Note Refer to the NMI PXTe 4322 User Manual for details about shielding the signals 9
19. ons 5 10 in i lt t _ 12 95 cm gt 6 02 in 15 28 cm A Caution Clean the hardware with a soft nonmetallic brush Make sure that the hardware is completely dry and free from contaminants before returning it to service Environmental Specifications Maximum altitude ccccccccceeesccesseeeeeseeesseeens 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree ccceeccececeeceseeseeteeeeteeeeeee 2 Indoor use only Operating Environment Ambient temperature range eects 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 low temperature limit and MIL PRF 28800F Class 2 high temperature limit Relative humidity range eeeeeseeeeteeees 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 NI PXle 4322 and TB 4322 Installation Guide National Instruments 15 Storage Environment Ambient temperature range Relative humidity range Shock and Vibration Operating shock Random vibration Operating Non operating Safety Voltages Maximum Voltage 40 C to 71 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 3 limits 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Meets MIL P
20. ssesseseeseeecsenees Shock and Vibration secsclesictsstesstcereitees Gutetes chores cls EE eaae daai Safety Voltages ccc cocccvesvessssdocsaescesdevaecauscaecaveavedvsnessesness ouddescvhdvdds E T E a Safety Standards 0 ee Electromagnetic Compatibility CE Compliance uu yi Online Product Certification seseesesessseseeeeesesretestesstsrststresrererseretresssretetnesrsrsternesreresseee Environmental Management sesesessseseeeseessesrstststsreretseterrerssretstessrsrstetsrsrersreereerereesetee Where to Go for Support sassis nenene er a E an EENE A Eep What You Need to Get Started To set up and use the NI PXIe 4322 module and TB 4322 terminal block you need the following items Hardware TB 4322 terminal block NI PXIe 4322 module NI PXI Express chassis Shielded twisted pair cabling and loads as required for your application 2 nicom NI PXle 4322 and TB 4322 Installation Guide Tools Number 1 and 2 Phillips head screwdrivers 1 8 in flathead screwdriver Long nose pliers Wire cutter Wire insulation stripper Documentation MI PXIe 4322 and TB 4322 Installation Guide and Terminal Block Specifications Read Me First Safety and Electromagnetic Compatibility MI PXTe 4322 User Manual NI PXI Express chassis user manual You can download needed documents from ni com manuals Installation Insta