BJ194Y-9SY Power Analyzer User Manual Version

image

Contents

1. 18 7 1 Input Password 18 7 2 Input Signal Selection 18 7 3 Communication Preferences 22 7 4 Digital Output Setting 24 7 5 Analog Output Setting 28 7 6 Time and Date Setting 31 7 7 Muti tariff Setting 34 7 8 System Setting 36 7 9 Menu Structure 38 7 10 Display Character instructions 40 8 PULSE OUTPUT A1 9 SAFETY CONSIDERATIONS
2. 42 10 MAINTENANCE 42 11 TECHNICAL SERVICE 43 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 2 BLUE JAY Product Manual Tectnology of Electronic Automatic 1 SUMMARIZE BJ194Y 9SY series Power Analyzer is a high end multifunction power meter It is the ideal choice for monitoring and measuring of power systems It can measure all of the power parameters in power grid Current Energy Voltage Power factor Frequency Current harmonics 2 15 times Active power Voltage harmonics 2 15 times Reactive power Voltage and current THD Apparent power Multi tariffs ratio And it can also transmit the parameter into 2 route relay output and 4 route switch input 1 route analog output For transformers generators capacitor banks and motors of the distributed detection automatic control system on line monitoring display It can replace the traditional analog or many digital measurement instruments Such as ammeter voltmeter power meter power factor meter frequency meter etc with the advantages of improving system reliability making the on site wiring convenient and reduce system cost With serial port BJ194Y 9SY
3. 7 6 6 Set minute In level 1 menu of TIME Choose item MIN meter shows like this tl an nin then press amp again enter the level 3 menu Use CKD and C to select the minute with setting value from 00 59 7 6 7 Set second In level 1 menu of TIME Choose item SEC meter shows like this E j nn SEL then press amp again enter the level 3 menu Use KD and C to select the second setting value from 00 59 7 6 8 Set billing date In level 1 menu of TIME Choose item E DAY meter shows like this 1 tian EJAY then press again enter the level 3 menu Meter will show Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 33 BLUE JAY Product Manual Tectnology of Electronic Automatic tian EdAY NMANI iJ I i Use CKD and C to select the billing date Note Default value is 0101 mean the billing date is At 1 00 on the 1st of each month NINI iJ tit t So the setting value max is 3123 which means each month 31st 23 00 Date time 7 7 Muti tariff Setting Press CA return to level 1 menu In this section user will set 1 Billing segment setting 2 Ttariff setting Note BJ 194Y contains 12 billing segments with th
4. User settings menu Communication settings menu Shows scal input value Set the decimal point Communication parameter setting Metter address setting Baud rate 8 data bits 1 stop bit even parity 8 data bits 1 stop bit odd parity 8 data bits 1 stop bit no parity Confirm the change Input voltage selection Input current selection Set CT ratio range range Set PT ratio Select phase Route 1 switch output settings Route 2 switch output settings System parameter settings Choose Setted parameter The corresponding parameters Set the alarm value Show Low alarm setting Show High alarm setting System password Year Month Week day Date Hour Minute Second Tariff segment Tariff Sharp Peak Flat Valley Billing day Tel 0086 023 86850812 Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 40 Email tech cqbluejay com BLUE JAY Product Manual Tectnology of Electronic Automatic 8 PULSE OUTPUT BJ 194Y power analyzer provides 2 routes pulse output for the total active energy and total reactive energy The host PLC DI module can cumulative the data of both the active and reactive power energy sent by the pulse from optocoupler relay 1 Electrical specification voltage VCC lt 48V Iz lt 50mA 2 Pulse 500
5. Choose item MON meter shows like this tl an non then press again enter the level 3 menu Use CKD and C to select the month with setting value from 1 12 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 31 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 6 3 Set week day In level 1 menu of TIME Choose item DAY meter shows like this El an JAY then press amp again enter the level 3 menu Use CKD and C to select the day with setting value from 1 31 7 6 4 Set date In level 1 menu of TIME Choose item DATE meter shows like this Hi an dALEH then press amp again enter the level 3 menu and gt gt gt to select the week day with setting value from 1 7 N 7 Use N 7 6 5 Set hour In level 1 menu of TIME Choose item HOUR meter shows like this tl nn Holir then press amp again enter the level 3 menu Use CKD and C to select the hour setting value from 00 23 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 32 BLUE JAY Product Manual Tectnology of Electronic Automatic
6. Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 36 BLUE JAY Product Manual oo eu LLr then press CY again to confirm clear all the energy data meter display 545 Lire SUrE And then press CH again to save the operation and exit Press CAD without save and exit 7 8 3 Set display mode In level 1 menu of SYS Choose item dISP meter shows like this 595 di 5P P then press GSA enter the level 3 menu user can choose the display mode 595 545 di SP di SP nAn RUto Note Man means the screen display will change by press QO and A Auto means the screen display will change in every 10 sec 7 8 4 Change the password In level 1 menu of SYS Choose item CodE meter shows like this 595 Lod amp Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 37 BLUE JAY Product Manual Tectnology of Electronic Automatic then press XY again enter the level 3 menu Use KVD and gt gt to input the new password Note Please do not change the password If necessary please contact Blue Jay technical 7 9 Menu Struc
7. 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing BLUE JAY Product Manual Tectnology of Electronic Automatic Screen 9 Display voltage harmonic data press CDH can show the 2 15 times data DTe afo ooo F LIU UW 2rgecnrory habia 0 OQ gy oni p E afo CID LLL OB ue dy Le Olt Di2 p 03 _bM PEE Do1 bo2 ea J Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 17 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 SETUP PROCEDURE The SETUP procedure of the BJ194Y 9SY is performed by means of several SETUP options Once into the SETUP use the keyboard to select different options and enter required variables 7 1 Input Password A 4 figure password is required to be entered in case that in case that the meter will work without permission At normal display mode press AD to enter the programming mode meter display PASS Meter display F Ask for the password Press gt gt gt to input the password number from 0 9 Press lt lt gt to move the cursor After password switch press GA to confirm the input If password is correct meter can enter next setting Notes the default password is 0001 7 2 Input Signal Selection
8. 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 1 BLUE JAY Product Manual Tectnology of Electronic Automatic Directory CONTENTS Page 1 SUMMARIZE 3 2 APPLICATIONS 3 3 FEATURES 4 3 1 Electricity metering 4 3 2 Specifications 5 4 INSTALLATION AND START UP 7 4 1 Installation 7 4 2 Connection Terminal 9 4 3 Connection Drawing 10 5 SCREEN DISPLAY 11 6 OPERATION MODE 12 7 SETUP PROCEDURE
9. Baud rate 3 Communication format Note Not all the meter have communication function please make sure your purchase meter first if no communication mode you can skip this section 7 3 1 Meter communication address setting One or some BJ194 meter can be connected to a P C With this system we can get all the parameters in one central point of reading The BJ194 has a serial RS 485 or RS 232 type output according to the model If we connect more than one device to the same communication line RS 485 we have to assign to each of them a different code or direction from 1 to 247 since the P C needs the identification of every measuring point In level 1 menu choose the item bus the meter shows like this bUS Then press CY gt enter the level 2 menu choose the item Addr the meter shows like this bUS Addr Press gt gt to input GA the number from 0 9 Press CKD to move the cursor After password press lt 7 to confirm the input value is 1 9999 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 22 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 3 2 Communication Baud rate setting In level 1 menu of bus Choose item BAUD and the meter shows like this bUS bAUd The
10. Choose item PArA meter shows like this Ho PHrA then press GA enter the level 3 menu user can choose the output parameter Ho i PACH ft 9 U Note The analog parameter can set la Ib Ic Ua Ub Uc P Q H F default is UA 7 5 3 Set the low value for transmission output In level 1 menu of AO 1 Choose item LDIS meter shows like this Ho idi 5 then press CDH enter the level 3 menu user can set the low value Ho man I WUL i Press to input the number from 0 9 Press CZD to move the cursor After password switch press CYD to confirm the input value is 1 9999 Default 0000 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 29 BLUE JAY Technology of Electronic Automatic Product Manual Note Alarm value is about the secondary side value such as AC100V AC5A Voltage unit is 0 1V Current unit is 0 001A Active power unit is 0 1W Reactive power unit is 0 1VAR Power factor Is 0 001 Frequency 0 01HZ 7 5 4 Set the full scale value for transmission output In level 1 menu of AO 1 Choose item HDIS meter shows like this Ho Hdi 5 then press CDH enter the level 3 menu user can set the full scale value f
11. Tectnology of Electronic Autes t 100V Maximum measured value is 100V 380V Maximum measured value is 380V aa a ns ULL USEL UG 380 Product Manual Note A different range will affect the accuracy of measurements If the accuracy is 0 5 Select 100V range means the minimum scale value is 0 5V 100 x 0 5 Select 380V range means the minimum scale value is 1 9V 380 x 0 5 7 2 3 Current measure range In level 1 menu of IN Choose I SCL meter shows like this tA 1 SEL then press CH enter the level 3 menu user can see the current range n LSL 5 5A Maximum measured value is 5A 1A Maximum measured value is 1A B S a SLL Note Select a different range will affect the accuracy of measurements if the accuracy is 0 5 Select 1A range means the minimum scale value is 0 005A 1 x 0 5 Select 5A range means the minimum scale value is 0 025A 5 x 0 5 7 2 4 Voltage transformation ratio In level 1 menu of IN Choose item r PT meter shows like this Tel 0086 023 86850812 Fax 0086 023 67636974 Email tech cqbluejay com Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 20 BLUE JAY Product Manual Tectnology of Electronic Automatic in r PE then press G ente
12. 70 Digital input COM pin 19 Route 1 digital output 71 Route 1 digital input 22 Route 2 digital output 72 Route 2 digital input 21 Route 2 digital output 73 Route 3 digital input 74 Route 4 digital input Lower connection terminal 14 13 12 1 9 8 7 6 5 4 C phase Current B phase Current A phase Current 4 Current A phase S1 input 9 Current C phase S2 input 5 Current A phase S2 input 11 Voltage A phase input 6 Current B phase S1 input 12 Voltage B phase input 7 Current B phase S2 input 13 Voltage C phase input 8 Current C phase S1 input 14 Neutral Voltage input Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 9 BLUE JAY Product Manual Tectnology of Electronic Automatic 4 3 Connection Drawing Power Supply 15 liefie lt lt s0 feo 48 47 eo so fse DK 2 1 22 211 20 19 PPPD 70 74 72 73 74 141312119 8 7 6 5 4 q E e N o e9 _ ii N U zo U gt IMPORTANT REMARK If power 0 01 is shown for any of the phases and voltage and current are not zero for this phase check out following points Assure that A B and C phases coincide in voltage and current Correct polarity Reverse the current transformer placed at this phase Note This connection drawing is for reference only the actual connecting
13. The 194Y 9SY delivers the visualization of parameters listed above by means of LCD type displays In the main display area shows 4 power parameters with other display area show the various parameters and state of meter on each page jump OTHER FEATURES Low size 96 x 96 mm panel mounting meter True R M S measuring system Instantaneous maximum and minimum values of each measured parameter Energy measurement indication through a lighting led RS 485 or Ethernet optional type communication to a PC Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 4 BLUE JAY Product Manual Tectnology of Electronic Automatic 3 2 Specifications 1 Reference standard Basic electricity GB T13850 1998 IEC688 1992 Active power GB T17215 2002 IEC61036 2000 Reactive power GB T17882 1999 IEC61268 1995 2 Accuracy standards a Voltage 0 5 fs Current 0 5 fs Active Power 0 5 fs Reactive Power 0 5 fs Apparent power 0 5 fs Power Factor 0 5 fs Active Energy 1 rd Reactive Energy 2 rd Frequency 0 05 rd 3 Input Voltage Rated 400V optional 100V Current Rated 5A optional 1A Frequency 45 65Hz 4 Load Voltage lt 0 5VA phase rated 220V Current lt 0 5VA phase rated 5A 5 Overload Current 1 2 times rated continuous 10 seconds for 10 times the rated Voltage 1 2 times the rated
14. continuous 10 seconds for 800V 6 Dielectric strength IEC 688 IEC 255 3 1989 2kV AC RMS 1 minute between input output case power supply Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 5 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 EMC Test standard Test voltage Electrostatic discharge immunity IEC 61000 4 2 8Kv test level 4 Electrical fast transient burst e input ikv Power sunoiy 2kV immunity test p PPly Surge Shock immunity test ey ae ivi mode test voltage 8 Work environment Temperature 20 C 60 C Humidity RH 20 95 No condensation 9 Protection Panel IP54 Case IP20 10 Storage Conditions Temperature 25 C 70 C Humidity RH 20 95 11 Working Power AC 80 265V 45 65Hz DC 80 380V DC 20 60V Optional Maximum power consumption 6W 12 Dimensions L x W x H 96mmx96mmx71mm 13 Installation hole size L x W 91 0 8mm x 91 0 8mm Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 6 BLUE JAY Product Manual Tectnology of Electronic Automatic 4 INSTALLATION AND START UP The manual you hold in your hand contains information and warnings that the user should respect in order to guara
15. terminal please refer to the label on the rear part Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 10 BLU E JAY Product Manual Tectnology of Electronic Automatic 5 SCREEN DISPLAY 5 1 Panel Diagram Four Tariff Indicator Current Quadrant Indicator GRR pii ai rg y ua O O O r ma 2 a 2 Yy nergy Parameter H k lt gt ie i THO MIN O var COMM Indicator E 3 A F H Hz p for Active power o kVA q for Reactive pawar Avg Imp Total Net Exp KVAR r To BBG BHBHE RA 53 KE Total Separate Tariff Data Indicator JE sei ee S NNG a Se or Be oe te ors se i Note Please see detail instructions of items at OPERATION MODE Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 11 BLUE JAY Product Manual Tectnology of Electronic Automatic 6 OPERATION MODE When the 194Y 9SY is powered up the entire symbol will be on and the meter starts to self test After some seconds the meter is ready for operation and shows one of the available screens lt K CH Parameters on display can be switched by pressing key CKD or C gt LCD shown on screen at any moment When the key lt gt is pressed the screen CURRENT values of each pha
16. them Before any adjustment replacement maintenance or repairing operation is carried out the instrument must be disconnected from any power supply source When any protection failure is suspected to exist the instrument must be immediately put out of service The instrument s design allows a quick replacement in case of any failure Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 42 11 BLUE JAY Product Manual Tectnology of Electronic Automatic TECHNICAL SERVICE FAQ s 1 The BJ 194Y Power Analyzer once cabled and connected is seen to give a correct voltage and current reading but shows negative values for active power generation This is an error with the cabling for the current transformer secondary the direction of the transformer current has to be respected as shown in the connection diagram The current transformers have a two face primary the current must pass from P1 to P2 giving the result in secondary S1 and S2 of 5 amps The error stems from a The current transformers have been incorrectly installed As a result it gives the direction of the current as passing from P2 to P1 to resolve this problem the current transformer does not have to be dismantled and installed again but the transformer secondary S1 and S2 just has to be inverted b The connection of the current seconda
17. 0 imp kWh pulse upto 80ms This means When the meter detect 1 kWh the meter output 5000 pulse Note 1 kWh energy is for secondary side energy data if there have PT and CT accessed primary side energy data is 1 kWh xPT ratiox CT ratio For example In measure time T the received total pulse is N Primary side input of voltage is 10Kv Primary side input of current is 400A Secondary side measurement range is 100V and 5A In the time T energy accumulated is N 5000 x 100 x 80 pulse output 47 ae active power reactive power Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 41 BLUE JAY Product Manual Tectnology of Electronic Automatic 9 SAFETY CONSIDERATIONS All installation specification described at the previous chapters named INSTALLATION AND STARTUP INSTALLATION MODES and SPECIFICATIONS Note that with the instrument powered on the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts This instrument is factory shipped at proper operation condition 10 MAINTENANCE The 194Y does not require any special maintenance No adjustment maintenance or repairing action should be done when the instrument is open and powered on should those actions are essential high qualified operators must perform
18. BLUE JAY Product Manual Tectnology of Electronic Automatic BJ194Y 9SY Power Analyzer User Manual Version 1 5 er BABB 2 2088 X pez 16 aa S ns imp Total Net Exp KVAR ae M A i Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing BLUE JAY Product Manual Tectnology of Electronic Automatic Read me When you use BJ194Y 9SY series Power Analyzer be sure to read this user manual carefully and be able to fully understand the implications the correct guidance of operations in accordance with user manual which will help you make better use of BJ194Y 9SY series Power Analyzer and help to solve the various problems at the scene 1 Before the meter turning on the power supply be sure that the power supply within the provisions of the instrument 2 When installation the current input terminal must non open voltage input terminals must Non short circuit 3 Communication terminal RS232 RS485 or Ethernet is strictly prohibited to impose on high pressure 4 Be sure the instrument wiring consistent with the internal system settings 5 When communicating with the PC instrument communication parameters must be consistent with the PC Please read this user manual carefully Please save this document Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13
19. DO2 in the open state Communication transceiver normal Note Detail information for each symbol please refer chapter 5 following sections as same Note in the high voltage measurement X10 mean the showing voltage value multiplied by 1000 in the screen diagram mean the voltage is 10X1 000 10 000volt Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 13 BLUE JAY Product Manual Tectnology of Electronic Automatic Screen 2 Display the three phase current la Ib Ic In the bottom Ep shows total negative active energy Screen 3 Display the total active power total reactive power and total factor In the bottom Eq shows total active energy Note In power data screen user can press key gt switch show Independent three phase active power Independent three phase reactive power Independent three phase e powerfactor aie Se oe ome T0000 1 T UDI y III LILILICL ee fe fe Se Se Dr ae Da Oe ee a OO aa Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 14 BLUE JAY Product Manual Tectnology of Electron
20. Power Analyzer can connect with PC and use Modbus to set programming and read the data Based on this power meters you can simply set up a monitoring system with the IPC and central software 2 APPLICATIONS All power parameter measurement Power factor measurement and control Energy Measurement Replacing the three phase power meter three phase electricity transmitter Transformers generators capacitors and electric motors distributed detection Medium and low pressure systems SCADA EMS DCS integrators Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 3 BLUE JAY Product Manual Tectnology of Electronic Automatic 3 FEATURES 3 1 Electricity Metering By means of an internal microprocessor it simultaneously measures PY es fn Single phase votage v x x x 7 F Phase phase voltage v x x x 7 Curent a ke Frequency e PP Powertector coso x xe x x Active power w me o Px Reactive power v xx x Active energy wn x Reactive energy vam 7 7 7 gt x Ce a re a a a a current THD maona x x Individual harmonic current content Up to the 15 th Notes Phase phase voltage is Uab Ubc Uca voltage data determined by the different wiring Available x Display and communications xx Only can read in RS485 communication
21. Press A_ return to level 1 menu In this section user will set 1 Input net mode 2 Voltage measure range 3 Current measure range 4 Voltage transformation ratio 5 Current transformation ratio Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 18 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 2 1 Choice the input net mode In level 1 menu use CKD and gt gt to choose item IN and the meter shows like this n then press CH enter the level 2 menu choose LINE meter shows n Line Then press G again enter the level 3 menu Use CK and gt to select the right wiring mode meter shows like this fete toe A i n ne Link nJ4 njJ Note Selecting the wiring mode must match with actual wiring or the reading data will go L wrong 7 2 2 Voltage measure range In level 1 menu of IN Choose item U SCL and the meter shows like this raja r C un then press CYD enter the level 3 menu user can see the voltage range Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 19 BLUE JAY
22. aling third village Pioneer Park Jiangbei District Chongqing 27 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 5 Analog Output Setting Press CA return to level 1 menu In this section user will set 1 Analog output type 2 Choose the electrical parameter 3 Set the zero value for transmission output 4 Set the full scale value for transmission output Note If the meter have more than one channel analog output you can set the AO 2 AO 3 as the following steps please select the appropriate output settings in the level 1 menu 7 5 1 Output type In level 1 menu use CKD and C gt gt gt to choose item DO 1 meter shows like this Ho then press amp enter the level 2 menu choose LINE meter shows Ho EYPE then press CH again enter the level 3 menu Use CKD and C to select the output type meter shows like this Ho 1 Ro l Ao EYPE EYPE EYPE iee H 0 ge Note output type can choose 12 20mA 4 20mA 0 20mA default is 12 20mA Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 28 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 5 2 Choose the electrical parameter In level 1 menu of AO 1
23. cess wire shall be met the current 2 5 square mm voltage of 1 5 square millimeters A Voltage input Input voltage should not exceed the rated input voltage products 100V or 400V Otherwise you should use external CT Suggest 1A fuse be installed in the voltage input side B Current Input Standard input current is 5A if greater than 5A should use external CT When the CT is connected with other instruments make sure wiring methods be used in series Before remove the current input connection must be sure to disconnect the primary circuit or shorted secondary circuit of CT In order to facilitate disassembly please do not connect to CT directly and the terminal block is suggested C Please make sure that the input voltage and current corresponding to the same phase sequence and the same direction Otherwise the Values and symbols will be wrong Power and Energy The input network configuration of instrument depends on the CT number of the system in the condition of 2 CT select the three phase three lines two components in the condition of 3 CT select the three phase four lines three component mode Instrument connection mode set of the instrument programming input network NET should be the same load wiring as measured wiring Otherwise the measurement instrument will lead to incorrect voltage or power In three phase three wire mode the measurement and shows the line voltage In three phase four wire mode the mea
24. e TYPE The meter shows a do i then press amp again enter the level 3 menu Use CKD and gt gt to select the output type meter shows like this do CYPE Cn Tel 0086 023 86850812 Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing do i CYPE or do cYPE Rir GFF Email tech cqbluejay com 24 BLUE JAY Product Manual Tectnology of Electronic Automatic r n Mean remote control mode there have pulse and level output mode more detail refer chapter 7 4 2 Host inquiry 01 05 00 01 FF 00 DD FA Relay value Address Code Relay address FF00 close 0000 open CRC Slave answer 01 05 o0 01 FF 00 DD FA Relay value Address Code Relay address FFOO close 0000 open CRC RS485 communication please refer to RS485 protocol document ALr Mean directly alarm mode OFF Mean the relay will not work 7 4 2 Set output delay In level 1 menu of DO 1 Choose item DELY and the meter shows like this dov i dELY Then pressC Y gt enter the level 3 menu user can set the delay value do dELY ugg i Press to input the number from O 9 Press CQ to move the cursor After password switch press CY to c
25. e billing segment 1 setting method in this manual 7 7 1 Set the billing time of segment 1 In level 1 menu use lt gt and C gt gt to choose item S EG1 and the meter shows like this SEL N Then press CYD enter the level 2 menu choose TIME The meter shows 5 E Cc i CU i Elan Then press GA again entering the level 3 menu Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 34 BLUE JAY Tectnology of Electronic Automatic Product Manual SEG tian NANN JUGU Use CKD and C gt gt to select the billing date Note Default value is 0000 which means the billing date is at 00 00 on each day AAAN WUU min sec Segment 1 is for the muti tariff starting time 7 7 2 Choose the segment 1 billing tariff Note BJ194Y provides 3 months of energy data use Sharp Peak Flat Valley T1 T4 to calibrate the total energy data Users can get monthly energy data from panel display or RS485 RS485 data refer to Communication protocol and calculate their energy cost You can set up 12 billing segment in one day The segment 1 setting steps are as follows and other segment setting method is the same In level 1 menu of S EG1 Choose item E Mod meter shows like thi
26. gg a om Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 26 BLUE JAY Tectnology of Electronic Automatic Product Manual Press gt gt gt to input the number from 0 9 Press CZD to move the cursor After password switch press C7 to confirm the input value is 1 9999 Default 5500 Note Alarm value is about the secondary side value such as AC100V ACSA Voltage unit is 0 1V Reactive power unit is 0 1VAR Current unit is 0 001A Power factor Is 0 001 Active power unit is 0 1W Frequency 0 01HZ 7 4 5 Set the hysteresis value In level 1 menu of DO 1 Choose item HYS meter shows like this do l then press CH enter the level 3 menu and user can set the alarm value do NAN I Wu i Press to input the number from 0 9 Press CZD to move the cursor After password switch press C55 to confirm the input value is 1 9999 Default 5500 Note hysteresis value is for preventing the relay repeated action Example Alarm value 3 700A hysteresis value 0 030A Rising edge alarm Measured value is 3 700A then relay action output alarm When measured value is bellow 3 670A the relay will be closed Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Ji
27. ic Automatic Screen 4 Display the frequency of a phase In the bottom Eq shows total negative reactive energy He Screen 5 Display the 4 tariff energy data In the top screen T1 T4 indicate current showing tariff In diagram show tariff_2 EO E3 indicate the last three month EO Three month total energy data E1 Last month energy E2 Last month energy E3 Month before last month energy In the bottom screen T1 T4 indicate the energy sum data in each tariff 70 00003948 DIN D2 D3 Di4 Le se j CJN Note Press key can switch show other energy data Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 15 BLUE JAY Product Manual Tectnology of Electronic Automatic Screen 6 Display real time clock The first line shows year Second line shows month Third line shows date In the bottom line shows Hour minute and second seg BB My Ya Ses es t Aa ce ee cA Hes Lea RP LA S amp S 1 3 z IG 0 i A A A cA He Hes a ONE DIR PIB ONE o Sh es ROT DOR a Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13
28. n press CYD enter the level 3 menu allowing us to set the Baud rate 2400 4800 or 9600 bUS bUS bUS bAud BAUd bRUd 2400 4800 9600 7 3 3 Choose communication format In level 1 menu of bus Choose item data and the meter shows like this bUS dAtHA Then press CA enter the level 3 menu allowing us to set the communication data format Factory setting n 8 1 bUS bUS bUS GALA JAER dRER ob Pai nf Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 23 BLUE JAY Tectnology of Electronic Automatic Product Manual 7 4 Digital Output Setting Press CA return to level 1 menu In this section user will set 1 Digital output type 2 Output delay 3 Choose the electrical parameter 4 Set the alarm value 5 Set the hysteresis value Note If the meter have more than one channel digital output you can set the DO 2 DO 3 as the following step please select the appropriate output settings in the level 1 menu 7 4 1 Output type In level 1 menu use CKD and C gt gt to choose item DO 1 and the meter shows like this dos then press CH enter the level 2 menu choos
29. ntee a proper operation of all the instrument functions and keep it in safety conditions The instrument must not be powered on and used until its definitive assembly is on the cabinet s door If the instrument is not used as manufacturer s specifications the protection of the instrument will be damaged When any protection failure is suspected to exist for example it presents external visible damages the instrument must be immediately powered off In this case contact a qualified service representative 4 1 Installation Mounting Instrument is to be mounted on panel cut out 91 0 8 x 91 0 8 mm Keep all connections into the cabinet Note that with the instrument powered on the terminals could be dangerous to touch and cover opening actions or elements removal may allow accessing dangerous parts Therefore the instrument must not be used until this is completely installed 15 x F To i e or for 6 L 62 p Front view Side view Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 7 BLUE JAY Product Manual Tectnology of Electronic Automatic Notes Input signal BJ194Y using a separate acquisition calculate for each measurement channel to ensure consistent in use for different load forms its a variety of connection mode Ac
30. o Hdl S NaN Lists i Press gt gt gt to input the number from O 9 Press CZD to move the cursor After password switch press gt to confirm the input value is 1 9999 Default 5000 Note Alarm value is about the secondary side value such as AC100V AC5A Voltage unit is 0 1V Current unit is 0 001A Active power unit is 0 1W Reactive power unit is 0 1VAR Power factor Is 0 001 Frequency 0 01HZ 7 5 5 Example of analog output Set analog output TYPE 4 20mA LdlS 0000 PARA select la HdlS 5000 This mean when A phase current is 0 000A output 4mA current is 5 000A output 20mA Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 30 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 6 Time and Date Setting Press CA return to level 1 menu In this section user will set the meter system time which will affect the function of Muti tariff 7 6 1 Set year In level 1 menu use lt K and gt gt to choose item TIME meter shows like this tian then press GA enter the level 2 menu choose YEAR meter show tian YEAr then press again enter the level 3 menu Use CK and gt to select the year setting value from 00 99 7 6 2 Set month In level 1 menu of TIME
31. onfirm the input value is 1 9999 Default 0010 Note The setting of relay value is indicating the width pulse output value 0000 is for level output The setting value resolution is 100ms which means 0001 is 100ms 9999 means 999 9s 0 for level output 1 9999 for pulse output Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 25 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 4 3 Choose the electrical parameter In level 1 menu of DO 1 Choose item PArA meter shows like this do PAA then press CYD enter the level 3 menu user can choose the output parameter Note There are two alarm mode indicate with XX H and XX L XX H mean the rising edge alarm XX L mean the falling edge alarm IA H mean when the A phase current is rising to a certain value then output alarm Example 13 H mean when one phase of A B C phase current is rising to a certain value then output alarm PS L mean when Three phase total power is falling to a certain value then output alarm 7 4 4 Set the alarm value In level 1 menu of DO 1 Choose item VALU meter shows like this do wALU then press CYD enter the level 3 menu user can set the alarm value do et eit U g
32. r the level 3 menu allowing us to set the current transformer nz r PE NAN tt UUU t Press to input the number from 0 9 Press CZD to move the cursor After password switch press lt 7 to confirm the input value is 1 9999 Note The input values represent the voltage transformer primary side voltage secondary side voltage Secondary side voltage is 100V or 380V user set it at section 7 2 2 7 2 5 Current transformation ratio In level 1 menu of IN Choose the item r CT meter shows like this n r CE then press CSA enter the level 3 menu allowing us to set the current transformer n r CE AANA t Wu i Press gt gt gt to input the number from O 9 Press CZD to move the cursor After password switch press CA to confirm the input value is 1 9999 Note The input values represent the current transformer primary side voltage secondary side current Secondary side current is 1A or 5A user set it at section 7 2 3 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 21 BLUE JAY Product Manual Tectnology of Electronic Automatic 7 3 Communication Preferences N Press CA return to level 1 menu In this section user will set 1 Meter communication address 2
33. ry in the current transformers have been incorrectly connected to resolve this problem just connect the S1 transformer secondary to the S1 on the meter and the S2 on the current transformer to the S2 on the meter The BJ 194Y once cabled and connected is seen to give an incoherent Power factor and Cos reading 0 01 or similar This is again a current transformer and voltage phase connection error phase A must correspond to the current transformer installed in phase A phase B must correspond to the current transformer installed in phase B and phase C must correspond to the current transformer installed in phase C This connection is clearly shown on the back of the analyzer 3 The BJ 194Y is measuring in average voltage and is displaying the secondary voltage for example 110 volts Ensure that the voltage Transformer ratio has been correctly set see section on chapter7 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 43 BLUE JAY Product Manual Tectnology of Electronic Automatic 4 The BJ 194Y does not correctly display the current reading It shows values varying between 0 to 5 amps of current Ensure that the Transformer ratio has been correctly set once correctly set the current measurement shall be shown correctly see section on chapter7 For any inquiry about the instrument performance or any fail
34. s SEG i Enod then press CYD enter the level 3 menu user can choose the billing mod SEL SEL Enod Enod tl nE PEAP Tel 0086 023 86850812 Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing Note Above mean Sharp Peak Flat Valley SEL SEL i Enod Enod FLAE i Lo Email tech cqbluejay com BLUE JAY Product Manual Tectnology of Electronic Automatic 7 8 System Setting Press CA return to level 1 menu In this section user will set 1 Backlight time of the LCD 2 Clear energy counters 3 Set display mode 4 Change the password 7 8 1 Set the LCD backlight time In level 1 menu use CKD and gt gt gt to choose item SYS meter shows like this 595 then press lt gt enter the level 2 menu choose LCd t meter show 595 LLdt then press GA again enter the level 3 menu Use CKD and to select the value Note Minimum step is 1 minute 0005 for 5 minutes which means if not any operation in 5 minutes the backlight will turn off Set value gt 1000 the backlight always on Set value 0000 the backlight always off 7 8 2 Clear energy counters In level 1 menu of SYS Choose item CLr E meter shows like this
35. se are now showing Pressing again the key XK the screen will show the following parameters successively In setting menu pressing CKD can move the setting cursor to left Pressing gt gt gt can enter the number 0 9 y FA This key named SET key pressing it can open the programming menu and return to previous menu Ps ai gt amp a ae This key named Enter key pressing this key you can exit it with saving any modification that you might have done in menu operation press Enter key and user can go to the next menu d Note Press key CKO or in normal standby status and the meter will show different data in main screen In the menu set mode when changes the parameter and exit setting the meter will ask to SAVE press CAD exit without saving press GA save and exit Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 12 BLUE JAY Product Manual Tectnology of Electronic Automatic Screen 1 Displays the three phase voltage Ua Ub Uc As shown Ua 380 0V Ub 380 0V Uc 380 0V JOGUE he 1 ita lt a Bot poz j In the bottom character Ep show total active energy is 83 6KWh In other display area region show the system information DI1 DI2 DI3 DI4 in the close state DO1
36. surement and shows the phase voltage Auxiliary power BJ194Y Series Power Analyzer with universal AC DC power input if not for a special statement we provide the 220VAC DC or 110VAC DC power interface for standard products Instruments limit work power supply AC DC 80 270V please ensure that the auxiliary power can match with BJ194Y series meter to prevent damage to the product A Suggest install 1A fuse in the fire line side B For the areas with poor power quality suggest install lightning surge suppressor and rapid burst suppressor to prevent lightning strikes Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 8 BLUE JAY Product Manual Tectnology of Electronic Automatic 4 2 Connection Terminal Upper connection terminal 15 16 50 49 48 47 oo so 58 2 1 ao aoe RP RP aP apr Gud rs456 RSAGEA Power supply 1 Supply voltage input 0 V 47 Active energy pulse output 2 Supply voltage input 220 Va c 48 Active energy pulse output 58 RS 485 49 Reactive energy pulse output 59 RS 485 50 Reactive energy pulse output 60 RS 485 GND 16 Analog output 15 Analog output Middle connection terminal 22 21 20 19 70 71 72 73 74 DO2 DO1 COM DI1 DI2 DI3 DI4 20 Route 1 digital output
37. tomatic Output type TYPE 12 20 4 20 0 20 Default is 12 20 Choose the electncal OA UB UC FR Default is UA parameter PArA Analog Output low value for Setting AO 1 transmission output 0000 9999 Default is 0000 LdlS full scale value for transmission output 0000 9999 Default is 5000 HdlS Year YEAR 00 99 Default is 20XX Month MON Ce a Teese one Billing time of segment 1 Default 0000 TIME Billing date of segment 1 S EG1 Sharp TinE Peak PEAK Flat FLAt Valley LOW Segment 1 billing tarfiff E Mod Muti tariff Setting E SEG Billing date of Billing time of segment 12 segment 12 Default 0000 S EG12 TIME Sharp TinE Peak PEAK Flat FLAt Valley LOW Segment 1 billing tarfiff E Mod Note Not all 194Y series power analyzer have the complete menu settings Please confirm your purchased power analyzer has the corresponding extension module Without the module the corresponding part of the menu is not valid Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 39 BLUE JAY Tectnology of Electronic Automatic Product Manual 7 10 Display Character instructions n dlana O IE mrii o C23 COWS oI ia T0 Coico co ma HA T aa EE E LEET Cu O i ru User passwords Input error
38. ture sep pec IME 0000 1000 Factory default is 0005 Clear energy Gemma counters CLr E Unrecoverable for Clear data SYS Manual or Display mode dISP Automatic Factory default is manual Change the password 0000 9999 Default is 0001 Net Lin e N 3 4 N 33 N1 Select the input signal network i ee measurement Voltage Range 100V 220V Select the range of measured U SCL 380V voltage signal Select the range of measured Signal input Current Range I SCL 5A and 1A current signal Voltage transformation 4 9999 Setting voltage signal ratio R PT transformation ratio 1 2 scale Current transformation 4 9999 Setting current signal ratio R CT transformation ratio 1 2 scale Address ADDR 1 247 Instrument address range 1 247 Communication Communication Parameters speed BAUD 4800 9600 Default is 4800 b us Protocol DATA 0 8 1 8 1 Factory default communication n 8 1 mode for the word n 8 1 Output type TYPE orn Alt OFF O Default is Alr Set output delay DELY 0000 9999 Default is 0010 ioj Choose the electrical 13 H Digital output z TE parameter PArA PS H U3 H ETAURA Set the alarm value VALU 0000 9999 Default is 0050 hysteresis value HYS 4800 9600 Default is 4800 Tel 0086 023 86850812 Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing Email tech cqbluejay com 38 BLUE JAY Product Manual Tectnology of Electronic Au
39. ure contact to Blue Jay s technical service Blue Jay After sales service Building 13 2 8 Jialing third village Pioneer Park Jiangbei District 400020 Chongqing Tel 0086 023 86850812 Fax 0086 023 67636974 E mail tech cqbluejay com Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing 44

Download Pdf Manuals

image

Related Search

Related Contents

Spire Maneo 1077  Guida per l`utente  Midelet julia UPI Lycée Clément Ader Bernay (27300) Sommaire  取扱説明書 LE-H611  TAC-AIR G2    PER L`ESECUZIONE DI LAVORI TEMPORANEI IN QUOTA  Operating Instructions  Installer`s Instruction and User`s Manual  392 electronics platform LAN&RS232 communication protocol  