1. Your Vital Air Source MODEL NUMBER 45043 450P A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL SAFETY INSTRUCTIONS CAUTION To reduce risk of electrical shock Do not disassemble Do not attempt repairs or modifications Refer to qualified service agencies for all service and repairs Do not use this product in an area where it can fall or be pulled into water or other liquids Do not reach for this product if it has fallen into liquid Use this compressor with 12 volt DC systems only This product should never be left unattended during use WARNING To prevent injury Never allow children to operate this compressor Close supervision is necessary when this compressor is being used near children This compressor will become very HOT during and immediately after use Do not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use Do not use this product near flames or explosive materials or where aerosol products are being used Do not operate this product where oxygen is being administered Do not pump anything other than atmospheric air Never use this product while sleepy or drowsy Do not use any tools or attachments without f
2. release head valve Head pressure will slowly decrease pressure will be released through the intake port of the compressor to allow smooth re starts under pressure If compressor s is hooked up to power source and if the power switch is left in the ON position for more than 7 to 8 minutes Compressor will automatically turn on for a short duration 3 to 5 seconds to recover pressure due to built in pressure switch This is a normal function of the compressor Always shut off power to the compressor when the compressor is not in use MAINTENANCE amp REPAIRS 1 Your air compressor is equipped with permanently lubricated maintenance free motor Never try to lubricate the compressor 2 Regularly clean dust and dirt from compressor cooling fins and motor housing 3 All repairs should be performed by Manufacturer or Manufacturer authorized service agencies only PROBLEM Compressor will not run Thermal Overload Protector cuts out repeatedly Excessive knocking or rattling Compressor air flow TROUBLESHOOTING CHART POSSIBLE CAUSE S No power or switch in OFF position Blown fuse Motor overheats Lack of proper ventilation ambient temperature too high Compressor valves failed Worn bearing on eccentric or motor shaft Cylinder or piston ring is worn Worn piston ring or inlet valve CORRECTIVE ACTION Make sure compressor switch is ON Disconnect compressor from power source replace fuse Refer to Speci
3. DENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MIS USE OR ABUSE
4. esired pressure is reached release the trigger and turn power switch on compressor off Note Your air compressor is equipped with a pressure switch cut in at 120psi cut out at 145psi This feature is designed to protect the air compressor from over pressure causing permanent damage to your air compressor The pressure switch automatically turns off the motor when the internal pressure of the air compressor reaches the factory set cut out pressure 145psi and restarts when the internal pressure drops below 120psi B TIRE DEFLATION 1 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock in place 2 Press the bleeder valve button on the tire gun kit to decrease tire pressure 3 When desired pressure if reached release the bleeder valve button to halt deflation C INLINE PRESSURE GAUGE The pressure gauge on the inflation gun provides convenient tire pressure monitoring when airing up or down not airflow of the compressor This eliminates switching back and forth between a tire chuck and a tire pressure gauge 2 Please note that during inflation and deflation due to air velocity pressure gauge cannot provide accurate pressure readings Release lever on the tire inflation gun during inflation to check tire air pressure _ NOTE To release excess pressure turn off compressor and disconnect hose from c
5. fications section for correct fuse Let compressor cool off for about 30 minutes for thermal overload switch reset Move compressor to well ventilated area or area with lower ambient temperature Service or replace compressor Service or replace compressor Service or replace compressor Service or replace compressor lower than normal or cannot pump to higher pressures SPECIFICATIONS Part No 45043 450P Automatic Portable Motor Voltage 12 volt Motor Type Permanent Magnetic Max Intermittent Pressure Max Duty Cycle 100 Continuous Min On Off 72 F amp 100 PSI Continuous Use 72 F amp 30 PSI Continuous Max Current Consumption Fuse 30 Amps Inline Pressure Gauge Built in Pressure Switch 120psi On 145psi Off Auto Reset Thermal Protection Yes LIMITED WARRANTY VIAIR Corporation warrants this product when properly installed and under normal conditions of use to be free from defects in workmanship and materials for a period of one year from provided date of purchase To receive a replacement or for repairs return the complete unit to retailer from whom it was purchased along with proof of purchase Returns should be made within the time period and conditions of the retailer s policy for exchanges If you are unable to contact your dealer contact VIAIR directly for repairs or replacement at our option PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCI
6. ir compressor from over heating and causing permanent damage to your air compressor The thermal overload protector will automatically cut off power to air compressor should internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should your compressor shut off suddenly after extended use do not attempt to restart air compressor Turn ON OFF switch of air compressor to the OFF position The automatic thermal overload protector will automatically reset when internal temperature of the air compressor drops below safe level After allowing air compressor to cool off for about 30 minutes you can safely resume use of the air compressor by turning on the air compressor 5 For your convenience and to protect the air compressor from_over pressure operation that can cause permanent damage to the unit this compressor is equipped with built in pressure switch with a factory set cut on pressure of 120 psi 5 and a factory set cut off pressure of 145 psi 5 During inflation of tire pressures between 115 psi to 145 psi if you stop inflation the compressor may not restart This is completely normal since inline pressure is greater than cut on pressure of the pressure switch and less than cut off pressure of the pressure switch To restart compressor deflate tire pressure to below 115 psi reconnect tire chuck to tire valve stem and resume tire inflation 6 Please note that you may ex
7. irst determining maximum air pressure for that tool or attachment Never point any air nozzle or air sprayer toward another person or any part of the body This air compressor is equipped with an Automatic Reset Thermal Protector and can automatically restart after the thermal protector resets Always cut off power source when thermal protector becomes activated Wear safety glasses or goggles when operating this product Use only in well ventilated areas After usage always release excess pressure from the coil hose by turning On Off switch to the Off position disconnect hose from compressor with the tire inflation gun still connected to the other end of the coil hose pull trigger on the tire inflation gun to release excess pressure SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS Please read and follow the operating instructions carefully to assure that you will enjoy the convenience and best use out of your air compressor IMPORTANT 1 Always operate the compressor AT OR BELOW THE MAXIMUM PRESSURE RATING of the compressor Refer to Specifications section of this manual 2 Always OBSERVE THE MAXIMUM DUTY CYCLE of the air compressor Refer to Specifications section of this manual for details Operations exceeding maximum pressure ratings and or duty cycle will result in damage to air compressor 3 Your air compressor is equipped with an AUTOMATIC THERMAL OVERLOAD PROTECTOR This feature is designed to protect the a
8. ompressor With the tire inflation gun still connected to the other end of the coil hose pull trigger on the tire inflation gun to release excess pressure SAFETY PRECAUTIONS 1 Always inflate tires to manufacturer s recommended tire pressures Exercise extreme caution when driving with aired down tires Re inflate tires before high speed roadway travel 2 Never exceed 20 M P H when driving with partially inflated tires 3 Never make sharp turns while driving with reduced tire pressure 4 Re inflate tires before high speed traveling on roadways 5 Use heat resistant minimum 200 PSl rated working pressure extension hose Do not use aftermarket hoses with less than 200 PSI working pressure Some aftermarket hoses may not be suitable for use with this air compressor due to heat and pressure typically generated by this type of air compressors IMPORTANT Always use an Open Ended tire chuck such as the tire chuck equipped on the tire gun kit for tire inflation when using a compressor without an air tank CAUTION Never touch the air compressor or_fittings connected to the air compressor other than the ON OFF switch with bare hands during or immediately after use The extension hose and fittings connected extension hose will become very HOT during and after use If necessary wear heat resistant gloves to remove hose from the compressor quick connect stud RECOMMENDATION This compressor is equipped with a poppet pressure
9. perience a slight delay about _ second of the compressor s motor starting when the ON OFF switch is turned on while compressor is pressurized when there is pressure in the line that the compressor is connected to This is a normal delayed reaction not a Compressor ON OFF switch malfunction 7 itis strongly recommended that you keep the vehicle s engine running while using the air compressor to prevent discharge of your vehicle s battery 8 ONLY OPERATE THE AIR COMPRESSOR IN WELL VENTILATED AREAS Compressor performance is enhanced when operating compressor with vehicle engine running TIRE INFLATION amp DEFLATION IMPORTANT Before attaching air compressor_power clamps to your vehicle s battery terminals check to make sure that the ONVOFF switch of your compressor is in the OFF position Attach the Positive battery clamp Red to the Positive terminal of the battery and the Negative battery clamp Black to the Negative terminal of the battery Always keep your vehicle s engine running while operating compressor to avoid draining your vehicle s battery CAUTION Your Portable Air Compressor is_Moisture and Dust Resistant but NOT WATER OR DUST PROOF Never place compressor in soft sand_while running the compressor Vibration from the compressor will cause the compressor to settle into soft sand resulting in compressor drawing in foreign particles Never expose compressor to water while running the compresso
10. r IMPORTANT Make sure compressor sits upright while operating compressor Avoid tugging at compressor if line is taut Instead move the compressor to the same side of vehicle as tires that are being aired up IMPORTANT Always make sure the Portable Compressor s power cord is uncoiled and fully extended when using your air compressor to avoid overheating the power cord Tire Inflation Gun OPERATION INSTRUCTIONS This air compressor comes with 1 4 quick connect stud An extension coil hose and a tire inflation gun are also included with your compressor Each end of the extension coil hose is equipped with a 1 4 quick connect coupler The tire inflation gun comes with a 1 4 quick connect stud pressure gauge rubber hose bleeder valve and tire chuck Attach one end of the extension coil hose to the stud on your compressor and the other end to the stud on the tire gun kit The tire gun kit can be used for both airing up and airing down Please familiarize yourself with the following functions of this versatile air tool A TIRE INFLATION 1 Attach one end of the extension coil hose to the compressor and the other end to the tire gun kit 2 Push the tire chuck with the lever in the upright position down over the tire valve stem and then push the lever down to the horizontal position to lock in place 3 Turn compressor switch on and hold down the trigger on the tire gun kit to begin inflation 4 When d
Download Pdf Manuals
Related Search
Related Contents
寶みください。 使用上の注意はカタログー取扱説明書をお遭 Page 1 @YAMAHA _ PARTS CATALOGUE A l CATALCGUE f DE Recombinant Human Turbo Dicer Enzyme Kit hawos Billy/Queen/Mühle Operating instructions 岩見沢市家庭ごみの分別ガイドブック P27-P32 User Manual MANUAL DE USUARIO 用戶手冊 TES® Functional Users Manual MOCCA BTB - Crem International 460 Presentation Audio Mixer Copyright © All rights reserved.