        RETROCAM User`s Guide
         Contents
1.  RETROCAM User   s Guide       6  If you are using the    Seitzer Guider     also known as    TVGUIDER     or the    DTI  Guider     also known as    PCGUIDER     in the direct mode  select a guide star and  commence guiding     7  If you are using the    DTI Guider   PCGUIDER     in the downward looking  mode  such as during use with the MODSPEC or Mark III spectrographs    a  On the Guider PC  press the    p    key to enter the parameter settings   b  Set the    Flip E W    parameter to    0       c  Set the    Guider Angle    parameter to  90   TCS Rotator Angle    d  Exit the parameter settings  select a guide star and commence guiding    8  Select the desired filter by clicking on its button   9  Click    GO    in the RETROCAM GUI     10  Once CCD readout is complete  the image will be displayed in the open ds9  window     11  To resume observing with the primary instrument after using RETROCAM   a  Using xmis  move RETROCAM to the    Out    position  b  Restore the telescope focus to its original setting using xtcs  c  If using the    DTI Guider    in downward looking mode     Move the guide probe to the    slit    position    Set the    Flip E W    parameter to    1       Set the    Guider Angle    parameter to  270   TCS Rotator Angle   d  Restore the guider focus to its initial setting    RETROCAM Control Panel   See the GUI screenshot on the following page     Warning  The    ABORT    button is currently malfunctioning  Use of the abort  button will cause RETROCAM t
2.  bright illumination  such as during sky flat or dome flat  exposures  you will encounter non negligible internal reflected light problems   These problems are severe enough to ruin your sky or dome flat  We plan to  eliminate this problem during future upgrades     6  Suggested uses for RETROCAM     An imager for targets of opportunity  SNe  GRBs  microlensing   monitoring projects  etc      Spectroscopy and photometry of the same target    Finder Camera for the MDM 2 4m         Morgan  et al  2005     RETROCAM  A Versatile Optical Imager for Synoptic Studies     AJ  in  press  preprints available at astro ph 0502274        RETROCAM User   s Guide       RETROCAM Startup  1  Login to retrocam  the dedicated linux machine which runs RETROCAM  as       visitor     On chichon  retrocam can be accessed from the desktop menu by  selecting    Data Acquisition     then    RETROCAM     On agung  select     RETROCAM    on the desktop menu  Password is set to the current visitor  password     2  Verify that the RETROCAM GUI is not running on any other console   Note  The simplest way to do this is to enter the command    ps  x    ina  retrocam xterm  Look for    retrocam    and or    ds9    in the process id table     3  Start the RETROCAM control GUI by typing    retrocam       Multiple windows will open during system startup     System startup is complete when the ds9 window  RETROCAM control  panel and a diagnostic xterm are the only open windows     The diagnostic xterm may be icon
3. EDs    Object  NGC 5676 RA   12 34 56 0 Dec    01 23 01 2  ExpTime  sec   fi      images  iz Image Type    Object bl  Filename  050401  4 4d SeqNo  fi   Observer s    Pogge  amp  Morgan    Data Directory    home retrocam data W Overwrite Files W Auto Display          Filter  Gag  i E    open   RETROCAM TCS MIS Status     ccD Temp  ON    TelFocus        Rotator PA    Finder      Guilder  xii Ve oe     Remote Command           Filenames    1  RETROCAM uses a    C like    filename convention that is demonstrated in the  RETROCAM GUI screenshot above  The     4 4d    suffix implies that filenames  will be appended with a four digit number equal to the sequence number that is  displayed  For example  in the case shown above  the first filename would be   1040917 0001 fits  The    SeqNo    will automatically index with each exposure  so  the next exposure would be  r040917 0002 fits  Changing the filename suffix to      3 3d    would reduce the number of digits in the filename to three        RETROCAM User   s Guide       2  The    SeqNo    is automatically reset to    1    when the filename is changed  but it  can then be manually set to any number     RETROCAM Shutdown   1  Under the    Session    menu in the RETROCAM control panel  select    Exit        Troubleshooting Guide   1  The CCD temperature is too high       The TEC    ON OFF    indication is located on the    CCD Temp    line in the  lower right hand corner of the GUI  Verify that    ON    is displayed  If not   turn o
4. RETROCAM User   s Guide       RETROCAM User   s Guide  April 2005    RETROCAM Specifications and Operational Guidance   1  RETROCAM is a science quality optical CCD camera installed on the 2 4m    telescope Multiple Instrument System  MIS   It is available for use with all of the  observatory   s primary instruments except the 8K direct imager  A detailed  description of RETROCAM can be found in the Astronomical Journal   Citations  for observational work done with RETROCAM should refer to this paper     2  Specifications    CCD  E2V CCD 55 20     1152 x 770     22 5um pixels  Dark Current  2 5 e sec pixel at  20  C  Gain  3 0  Pixel Scale  0 259 arcsec pixel  Readout noise  13 4 e pixel  Readout time  6 sec  Cooling  3 stage thermoelectric   20 1  C    Field of View  4 97 x 3 32 arcmin   Filters  SDSS g  r iand z  One open position    3  RETROCAM uses the MIS finder mirror  now renamed RETROCAM   which  obscures the science field of the primary instrument  So  while RETROCAM can  be used within minutes of most primary instruments  the two cannot be used  simultaneously  The finder mirror has been resized such that a  100 arcmin   horseshoe shaped guide field is available around the perimeter of the MIS  aperture     4  RETROCAM is parfocal with the CCDS  Operation with the Mark III  Modspec  or TIFKAM spectrographs or any of the direct imaging cameras requires a small  telescope focus offset  see table in the    To Observe with RETROCAM    section      5  Under conditions of
5. gs properly     6  RETROCAM is completely locked up  I can   t operate the GUI at all     Close the RETROCAM and ds9 windows     Open the diagnostic xterm     a prompt should be available     Restart RETROCAM       
6. ified     To Observe with RETROCAM   1  Using the xmis control panel on chichon  move RETROCAM to the     In    position     2  Select the focus offset appropriate for the primary instrument in use                                Instrument Telescope Focus Offset  Secondary  Mirror Encoder Units   CCDS 0  TIFKAM  50  MODSPEC  128  Mark III  171  Direct Imagers  Templeton  Echelle   15            This value was measured using the RETROCAM    r filter and the Johnson Cousins    R     filter with Echelle  Focus offsets with other filters have not yet been measured and are  likely to be different    Set the telescope focus to the RETROCAM position using the xtcs control   Example  If Mark III is in use and the current focus is 3174   31744 171 3345  Set telescope focus to 3345 using the xtcs control     3  Fill in the Object  RA  Dec  Image Type  Filename  Observer and Rotator PA   Instrument Rotator Angle  fields in the RETROCAM GUL  Verify settings in the     Data Directory    field     4  Set the desired ExpTime and  Images in the GUI     5  Move the guide probe away from the center of the field until guide stars come  into view  Note that the guider may need to be focused if a telescope focus offset  was inserted in step 2     Note  When using RETROCAM for C  Morgan and C  Kochanek   s lensed  QSO monitoring project  pre selected guide probe positions are available  using the    retrocam_gs    program on chichon  See the    Lensed QSO  Observing Procedure    for details       
7. n the TEC by selecting    Cooler ON    in the    Temperature    menu     2  No stars appear in the image following CCD readout     Verify that RETROCAM is in the    In    position on the xmis control panel     3  Images are out of focus     Ensure that you have entered the appropriate focus offset for the  primary instrument in use  See section 2 of    To Observe with  RETROCAM for details     4  Iraf is reporting some inscrutable errors when I am attempting to display  images in a ds9 or ximtool window     The RETROCAM ds9 window will cause conflicts with Iraf ds9 or  ximtool windows  Discontinue using Iraf on retrocam  and perform data  analysis using another computer  A restart of the RETROCAM software  may be necessary     5  Ican   t find any guide stars     The RETROCAM mirror occults the central region of the guide field   Approximately 100 arcmin    of unvignetted guide field is available in an  annular region around the center  The guide probe may be in the shadow  of the finder mirror     Attempt to focus the guider  Inserting a telescope focus offset will put  the guider out of focus  and refocusing may be necessary to resolve guide  stars on the TV screen     If you are using the    DTI Guider     the combination of integration time   gain and the settings of the    White    and    Black    knobs may be preventing  you from seeing the star on the screen  Follow the steps in the    DTI  Guider    section of the 2 4m Telescope User   s Manual to adjust these  settin
8. o lock up  requiring system restart     1  The following parameters are set using the RETROCAM GUI     Exposure Time    Number of Images to acquire in a sequence    Image Type  Object  Dark  etc      Filename  see additional guidance under    Filename    below     File sequence number  automatically resets to    1    with each new  filename     Data directory  usually  home retrocam  data     2  Filters are selected by clicking on the appropriate filter button using the  mouse  The button will appear yellow during filter wheel motion and will  appear green when the selected filter is in place     3  The following FITS header information can be updated in the GUI     Object Name       RETROCAM User   s Guide         Object RA and Dec  Note  This feature is informational and does not  change telescope RA amp Dec  Future versions of this program will retrieve this  information from xtcs automatically       Observer Name s      Instrument Rotator Position Angle  PA     4  The lower right corner of the GUI displays the following information     CCD Temperature    Telescope Focus   not yet implemented     Instrument rotator position angle  PA     Finder Mirror Position  not yet implemented     Guide Probe Position  not yet implemented     5  The thermoelectric cooler  TEC  controls can be found in the    Temperature     menu  The TEC is automatically set to maintain  20 1  C upon startup   Additional adjustments should not be necessary        Session Configure Observe Temperature L
    