Home

SMOKE& STROBE COMBO

image

Contents

1. PHOTOELECTRIC THE PROFESSIONAL STANDARD CAT 70 l ORSIL 120V AC 60Hz Wire in with two AAA Battery Backup for Alarm O O Description The BRK Brands Inc Model Number 7010BSL is a wire in 120V AC 60Hz single and or multiple station photoelectric smoke alarm with integrated 177 candela strobe light specifically designed for residential and institutional applications INTEGRATED including sleeping rooms of hospitals hotels motels dormitories and other multi SMOKE ALARM amp family dwellings as defined in standard NFPA 101 Model 7010BSL complies STROBE LIGHT with UL217 UL1971 CSFM NFPA 72 HUD FHA and other agencies that model mee their codes after the above agencies They meet building codes where AC with One device includes both a strobe light battery backup silence photoelectric smoke alarms are required The alarms are and photoelectric smoke alarm Re interconnectable with up to 18 devices of which 12 can be smoke alarms quires only one electrical box Saves installation time The BRK 7010BSL alarms feature a photoelectric smoke sensing chamber an inte grated 177 candela strobe light an 85dB horn and AAA battery back up for alarm SMART STROBE The Strobe Light is designed to provide deaf amp hard of hearing individuals with a visual warning of a fire The Smart Strobe has separate flash patterns for smoke Separate flash patterns to distinguish heat and carbon monoxide dangers when connected to a First Alert C
2. flashes then 5 seconds off Pattern is repeated Indicator Lights Sounds AC Power Constant Green LED DC Power Intermittent Red LED Local Alarm Red LED flashes rapidly steady flashing strobe Remote Alarm Red LED out Listing Listed to UL217 amp UL1971 Standards Individual Carton Dimensions 5 25 L X 4 13 W x 5 44 H 117 1 CSFM NFPA 72 NFPA 101 and the ICC Weight 0 97 Ibs Cube 0 07 ft3 UPC 0 29054 12104 2 Installation of this smoke alarm must conform to all local electrical codes and Article 760 of the National Electrical Code NFPA 70 B Master Carton Dimensions 12 63 L x 5 81 W x 5 94 H and NFPA 72 Interconnected units must meet the following or Master Pack 3 requirements Total length of wire interconnecting units should p be less than 1000 feet be 18 gauge or larger and be rated at II Weight 3 24 Ibs least 300V It is recommended that all units be on the same fuse Cube 0 25 ft3 or circuit breaker If local codes do not permit be sure the neutral wire is common to both phases I2of5 300 29054 12104 3 THE PARTS OF THIS SMOKE ALARM Pallet Information Cases per Layer 24 1 Mounting bracket S Number of Layers 1 2 Mounting Slots S 3 Locking Pins MWL A Cases per Pallet 168 si Hot BAS AG Wie 2 Units per Pallet 504 5 Neutral White AC Wire G 6 Interconnect Orange Wire Cube 47 5 ft3 7 Pull out Battery Drawer 8 Quick Connect Plug A Weight
3. 609 Ibs 2014 BRK Brands Inc a Jarden Corporation 2 Ceiling or Wall 3 Power Connector 4 Wire Nut 1a Smoke Alarm 1b Smoke Strobe Combo 6 Neutral Wire White A Unswitched 120VAC 60 Hz source B To additional units Maximum 18 total Maximum 12 Smoke Alarms 5 Electrical Box 7 Interconnect Wire Orange 8 Hot Wire Black BRK THE PROFESSIONAL STANDARD brkelectronics com ms02 Company NYSE JAH 3901 Liberty Street Road Aurora IL 60504 8122 All rights reserved First Alert is a registered trademark of the First Alert Trust BRK is a registered trademark of BRK Brands Inc
4. O alarm between smoke and carbon monoxide This helps a hearing impaired person better distinguish the danger present The 177 candela Xenon strobe meets UL 1971 requirements and flashes at a rate of 177 CANDELA an average of 60 times a minute This alarm features two latching features and XENON STROBE two silence features Alarm Latch Easily identifies initiating alarm even after alarm condition has subsided Low Battery Latch Identifies which unit is in low bat Powerful 177 candela xenon strobe light tery condition by blinking the green power light Low Battery Silence Temporarily provides effective visual warning to silence the low battery chirp for up to eight hours Alarm Silence Silence alarm hearing impaired residents for several minutes Optipath 360 technology provides 360 degrees of direct ac cess to the smoke sensing chamber Replace battery without removing alarm from ceiling Other Contractor preferred features include a dust cover keyhole slots 1 Hz FLASH RATE in the mounting bracket eliminate the need 60 flashes per minute rate meets to remove the electrical box screws for ADA ANSI 117 1 NFPA 72 and UL1971 installation two locking features requirements for visual signal devices and a Quick Connect wiring harness OPTIPATH 360 TECHNOLOGY Provides 360 degrees of direct access to the smoke sensing chamber BATTERY BACKUP Two AAA batteries provide backup for the smoke alarm during power outages Note wi
5. ion has subsided Low battery latch to visually identify which unit is in low battery condition Two Silence Features Alarm Silence to temporarily silence nuisance alarms Low Battery Silence to silence low battery chirp for up to 8 hours 8 Two Locking features tamper resistant locking pins that lock battery drawer and or alarm to mounting bracket 9 The unit shall be capable of operating between 40 F 4 C and 100 F 38 C and relative humidity between 10 and 90 10 The unit shall have a plug in connector and be capable of interconnection of up to 18 alarms 12 of which can be smoke alarms 11 The unit shall ata minimum meet the requirements of UL217 UL1971 ADA ANSI 5 1 dia x 4 0 H 10 9 0z 120V AC 60Hz w two AAA battery backup for alarm Voltage Range 108V AC to 132V AC 0 05 0 60 amps standby alarm 40 F 4 C to 100 F 38 C Humidity Range 10 to 90 relative humidity RH Audio Alarm 85dB at 10 feet Test Silence Electronically simulates smoke condition causing the unit to alarm Press and hold test silence button Alarm Reset Automatic when smoke clears Interconnections Up to 18 units of First Alert or BRK Smoke CO and Heat Alarms Maximum of 12 smoke alarms See user s manual for details Smoke Sensor Photoelectric Strobe Light 177 candela Xenon strobe Flash Rate 1 Hz Smoke Alarm Constant approx 1 flash per second CO Alarm Intermittent approx 1 flash per second for four
6. ll not power the strobe light Listed to p UL 217 UL 1971 PHOTOELECTRIC OSUEEKE WON 70 10BSL OMO TOP VIEW SIDE VIEW The integrated strobe light amp smoke alarm shall be a BRK Model 7010BSL and shall provide at a minimum the following features and functions 1 A photoelectric smoke sensing chamber CEILING Percent Light Intensity Angle In Degrees WALL 50 55 55 45 60 40 MOUNTING i i BRACKET 75 30 LIGHT 80 30 FIGURE 1 Light Output 85 25 for Ceiling Mount 90 25 45 f FIGURE 2 Light Output for Wall Mount 90 Alarm Dimensions Weight Operating Voltage Operating Current Temperature Range 2 A177 candela Xenon strobe light The Smart Strobe shall have separate flash patterns to distinguish between smoke heat and carbon monoxide dangers 3 Fully screened sensing chamber to resist entry of small insects thereby reducing the probability of unwanted alarms 4 Powered by 120V AC 60Hz and have a monitored two AAA battery backup for alarm and a solid state piezo horn rated at 85dB at 10 ft and be capable of self restoring 5 A visual green LED power on indicator to confirm unit is receiving power or is in alarm 6 A full function test button should check all alarm functions by simulating a smoke condition causing the unit to alarm 7 Two Latching features Alarm Latch to easily identify initiating alarm after alarm condit

Download Pdf Manuals

image

Related Search

Related Contents

Remote Deposit FAQs - NASA Federal Credit Union  SYSDRIVE 3G3HV  PRESENTS COMMERCE DE DETAIL 15092009  BULLETIN DE SERVICE - G-Nav  Full page fax print  Graficast Automotive & Deco films  取扱説明書 (保証書付)  USER MANUAL E-SERIES MUSIC PLAYER  Instalacion  510 KB - Bureau de la sécurité des transports du Canada  

Copyright © All rights reserved.
Failed to retrieve file