Home
        SVT-2 7" Indoor Monitor A & B
         Contents
1.    SVT 2 7  Indoor Monitor A  amp  B       User Manual    Playback Call Record            Please read this user manual prior to installing the system  and keep it well for future use     1  Parts and Functions       e Digital TFT LCD Screen       Emergency Button    Message Indicator    UNLOCK Button       TALK MON Button          e Microphone                e Mounting Hook       m e Speaker                               Connection Port                                              O ox 4 5 e Mounting Hook  2   6 G    s              Key functions    Display the visitors  image  Emergency button    Message indicator   It will light when the monitor receives a call from the outdoor station    Unlock button Press to release the door   Talk Mon button Press to communicate hand free with visitor or press to  view the outdoor station s camera in standby mode   Sends out communication from user to guest   Mounting hook Use to hang up the monitor    Connection port  Sends out communication from the guest to the user    DIP Settings    DIP1 amp 2 APA Reserved  left to default        Set to OFF  When the monitor is in the middle of the line in daisy chain connection           Set to ON  When the montior is at the end of the line or connected to a SVT DBC4           2  Monitor Mounting                               145 160 cm       oe 40 4 0 6 6 6 6 6 6  P ao SOE SO SOE SE OE ES OE SE OEE  am re et eS a OO  Or A  E  r E Se Oe Se ee Se Se Se Sa Se 2  r E SA SM    A SU  SA EN SY    SA E   
2.   Time Settings  en ie on main menu screen  or on door camera switching mode screen   then  select    Date  amp  Time  item to enter the date  amp  time settings screen  You can set  the date  amp  time on this page  Fy Touch icon to exit the setting and return main menu  screen         e       More    Transfer Close    z    Intercom Playback Call Record    Sounds    Date  amp  Ti    e       Transfer Light Close    Language    Do not  Disrupt    About    Home       Note  You can set your own time  you  can also synchronize the system time     Sync    Sync From System Clock       Rename  amp  Monitor Time Settings    Touch i on main menu screen  or on door camera switching mode screen   then  select  More     item to enter the Rename  amp  monitor time settings page You can  set door station rename  camera rename  monitor time on this page  am Touch icon to  exit the setting and return main menu screen       4  an      Sounds Monitor Intercom Playback Call Record    5  amp   ia    Monitor Intercom Playback Call Record  Date  amp  Time      a  I  OD        Language N r  4       Do not    More    Risrupt Transfer Light Close  About  Home      TR Transfer Close       a  r     DoorStation Rename  ia Camera Rename    Front Door ar 1 CM 1    Back Door i  2 CM 2    r    a 3            afe    e  Monitor Time Set             Note  If you want to rename  please touch the place of name  then it will turn keypad  page  you can input your new name in this screen    DOOR3 RENAME       Door 
3.  1 2 3 4 to monitor the door station or CCTV camera you want  Press       Gy  icon to exit and enter into the main menu screen     X    Playback Call Record       Note  if the system is connected to a SVT 2 AC31 camera throught a SVT 2 SCU    press the camera 1 2 3 4 to monitor the camera you would like  Press Bjicon to  exit and go back to the main menu screen     5  Intercom Function    Touch Ce Intercom icon on main menu to get into the intercom mode  then select one of    the following  Inner Broadcast  Inner Call  Name List Call and Call Guard Unit          Playback Call Record       j Inner Broadcast  If multi slave indoor monitors are installed in the same system      either single family or apartment system   select Inner Broadcast  and all indoor  monitors will automatically receive broadcast content at the same time     2  Inner Call  If multi slave indoor monitors are installed in the same system  either    single family or apartment system   select Inner Call  and all the other indoor monitor  2           will ring at the same time  Whichever indoor monitor answers the call  the  communication starts and the other indoor monitors stop ringing automatically   Refer to Slave Indoor Monitor on page 11     3  Name List Call  Indoor monitors can call other indoor monitors in the system   Touch Name List Call icon  the namelist will be created automatically by the  system  on intercom mode menu page  Select a name on the screen then touch    icon to call Press   icon to
4.  enter last next name list page   Touch Dial  Number icon again to redial        Name List  Jim  Zhang  Calo  Liu    Jacko  Zhang  Philips  Chen  Hebe  Zhang  Tony  Li       4  Call Guard Unit  A indoor monitor can be assigned as Guard Unit Monitor  when the  Guard Unit Monitor answers the call  conversation with the guard person is started      6  Video Picture Memory    Video Picture Recording  Both Auto Recording and Manual Recording are available  Auto Recording is  default  When the system receives a call  after 3s  the indoor monitor will record    one video picture for each call automatically  You may also touch icon to  record the visitor s video image      Video Picture Playback    Touch 5 Playback icon on main menu  the recorded videos pictures will be played on  screen  please note that touch Pi icon to Start Pause the videos recorded     _4           Ba      A e V    Monitor Intercom    WA    Donot    Disrupt Transfer    Image 008 020    2014 06 23       14 36 55    Note  When the system without SD card  1 118 pictures in inner memory  2 Manage each picture     When the system with SD card 1 Up to 32G Micro SD card    2 Video  amp  Audio record  3 Manage each video clips    4 Can be copied    7  Call Record Function    Call Record  All calls including Outdoor station to monitor call  indoor monitor to     indoor monitor call  will be recorded and can be reviewed afterwards     Touch Call Record icon on main menu to get into the call record mode When there  are unr
5. E E Or Sr ir Sr SO Se SO SE 2                               1  Use the screws to fix the mounting bracket on the mounting box  Accesories  include a bracket  two pieces of 4X25 screws which are needed for fastening  the mounting bracket and a green connector     2  Wire the system correctly  then hang the Monitor on the Mounting Bracket firmly     3  Main Menu    ana       Touch anywhere in the screen when in sa area cal Bord  standby mode to bring the screen to     the main menu       Disrupt Transfer       4  Basic Door Release Operation    l  Press CALL button on outdoor station  the wwassayn     indoor monitor rings  and at the same time   the screen displays the visitors  image     2  Press TALK MON Button on monitor  or touch icon on screen  you can  communicate hand free with the visitor for  90 seconds  After finishing communication pres   amp   TALK MON button again or  touch    icon to end the communication  If nobody answers the call the screen  will be turned off automatically after 30 seconds              3  During talking state  Press   J   UNLOCK Button or touch ai icon to open the door    for the visitor af two locks are connected to door camera touch e unlock 2nd  icon to release the second lock      4  When the monitor is in standby mode  press  a    TALK MON button  The screen can  display the view of outside  Or touch fagq Monitor icon on main menu to get into the  door camera switching mode  if multi outdoor stations are installed  you can press the  door
6. Station Rename          P   Front Door  A z awm             aw LEJ RJ LJ llu LJ Lo Le     montor EW z x cv Le Ln  in KE  30 se 723 eee a o TY    Screen and Volume Adjustment    icon  and the adjust screen will be       During monitoring or talking state  touch        displayed     1  The Scene mode selection  Total 4 screen  modes can be selected in sequence  Normal   Brightly  Soft and User  Whenever you modify  Brightness or colour  Scene item will be set to  User mode automatically        2  Note that all the modifications will be performed immediately after the operation   Touch the window of image to exit the adjust page      9           13  Restore to Default    The restore to default function allows the user to recover the settings to factory setting   Note that the restore to default operation will not change the setting and datas     Enter main menu screen and touch fag icon  then select  About  item  or touch logo  position  to enter the about settings page  touch d  icon  the default settings will be  loaded     Touch f icon to enter the Memo Information page  touch and icon to copy  the pictures to SD card  Touch and icon to format SD card and restart     About Memo Information    Local Address SD Card  Video Standard Video Capacity    System Verson Video Usage  Display Driver Flash   Front Image Capacity  UI IMEC CASEET G    Memo Information  SD Card  Video Capacity  Video Usage  Flash  Image Capacity  IMEC CASER       14  Monitor Parameter Setting    How to ente
7. The code number of 8012 is used to set the time format as 12 hour system  The code number of 8013 is used to set the time format as 24 hour system    How to set the indoor monitor panel ON    In default mode  when receiving a call  all masters and slave indoor monitors will  ring at the same time  The system allows up to 4 indoor monitors to display the image  when a call is received at the same time  To program this setting  just input the code  8006 on each indoor monitor     Press call button  on door station    E Ts    When reveiving calling all monitors can display the image at the same time                      Master monitor  1st slave monitor  2nd slave monitor  3rd slave monitor          How to set the unlock parameter    Unlock mode     There are two unlock modes    power on  to unlock type unlock mode 0 by default   2 power off to unlock unlock mode 1    The code number of 8010 is used to set the unlock mode to 0   The code number of 8011 is used to set the unlock mode to 1    Unlock time   The unlock time can be changed by at any time  It can be set from 1 to 9 seconds  The    code number from 8021 to 8029 are used to set the unlock time to 1  9 seconds     How to set the user code for the monitor   There are 3 DIP switches in total  Bits 1 and 2 are reserved and must be on the default  position  The Bit 3 is used to configure the position of each indoor monitor in the  connection line  It must be set to ON if the indoor monitor is in the end of the line   paralle
8. ead call records  arrow color red  Press the unread call record  and then touch  gt     icon to play it     06 23  06 18  06 12  05 29  05 27  04 20    Donot  Disrupt       Note  1 Limited number of records     Call Record    06 23    2 Do not need to delete any a 06 18   06 12   record  oe  05 27   04 20    Call Record    15 22  20 54  11 06  08 39  21 43  13 16          01 05    Calo Liu  Smith    eee Yang    01 05  Calo Liu  Smith    Vincent Yang  Allen Chen  EGEA ae   Ben Wu       8  Do Not Disturb Function    Touch   Do Not Disturb icon on main menu to get into the Do Not disturb mode  then  select of the the following  Normal  In 1 Hour  In 8 Hours and Always  You can select  the appropriate item according to your needs     Do Not Disturb         Normal  In 1 Hour  In 8 Hours    AMENE       Note  When you select  In 1 Hour  or  In 8 Hours   the remaining time will be  displayed on the bottom of the screen     9  Transfer Function    Touch a Transfer icon on main menu to get into the transfer mode  Touch the    empty place  and then input the telephone number by pressing the digital keypad And it  has 3 types of divert modes     1 Don t Transfer      calls from outdoor station will not be diverted    2 If No Answer      outdoor station calls indoor monitor firstly  the the call is not  answered within 30 seconds  it will be diverted to the telephone number  programmed  The indoor monitor will turn off immediately when SVT 2 TPS  diverts sucessfully  Note  this action wil
9. l connection  or connected to a DBC 4 module  It must be set to OFF if the indoor  monitor is in the middle of the line  daisy chain connection     31  Please refer to the following table                                                     8200 Code 0 8211 Code 11 8222 Code 22  8201 Code 1 8212 Code 12 8223 Code 23  8202 Code 2 8213 Code 13 8224 Code 24  8203 Code 3 8214 Code 14 8225 Code 25  8204 Code 4 8215 Code 15 8226 Code 26  8205 Code 5 8216 Code 16 8227 Code 27  8206 Code 6 8217 Code 17 8228 Code 28  8207 Code 7 8218 Code 18 8229 Code 29  8208 Code 8 8219 Code 19 8230 Code 30  8209 Code 9 8220 Code 20 8231 Code 31  8210 Code 10 8221 Code 21    ee          10  Specification    e Power supply for indoor monitor     e Power consumption   e Monitor screen    e Display Resolutions   e Video signal    e Wiring     e Dimension     DC 20 28V   Standby 12 4mA  Working 270mA  7 Inch digital color LCD   800 3 R  G  B  x 480 pixels   1 Vp p  75 Q  CCIR standard   2 wires  non polarity    131 H  X 225 W  x 18 D mm          The design and specifications of this user manual can be changed without any notification to the user   All copyright and interpretation rights are reserved to SVT Innovations Inc     
10. l not affect the communication between  SVT 2 TPS and outdoor station    3 Simutaneously      calls from outdoor station will be diverted to your telephone  simutaneously  The indoor monitor will not turn off when SVT 2 TPS diverts  sucessfully  however if one answers the call at the indoor monitor  the SVT 2 TPS  will hang up automatically     Transfer Options         Playback Call Record    Don t Transfer    If No Answer    Simutaneously             Note 1 Touch Qi icon to detect the transfer device info     Transfer Options  Don t Transfer    If No Answer    Simutaneously  1   2   3        10  Staircase Light    Function is reserved  Not available for SVT 2 system     11  Basic Setup Instructions  Sounds Settings    Touch icon on main menu screen  or on door camera switching mode screen   then  select  Sounds  item to enter the sounds settings page You can set a variety of ring    tones on this page  a Touch icon to exit the setting and return main menu screen         q       a         Monitor Intercom Playback Call Record  Date  amp  Time   Pa  l  I         Language Wi i    More    Penal Transfer Light Close    m a i  Ss  amp   ia  Monitor Intercom Playback Call Record    we 7 O    boner Transfer Light Close    About       Note  Door Ring have 2 modes    a   United and Seperated  If select  United   Door1   Door2   Door3   Door  intercom Bell   Alert  it means Door1 2 3 4 will be adjust with 3   the same ring tone  ad FT Corrina oe    United    Seperate          Date  amp
11. r the installation setting screen    INSTALLER SETUP  About    Local Address  Video Standard       Speer EE     gt  Wwe  m oe  ca   aha  ala  Gaia   ia  laia  Gia Gaa a aea  a wW    c ESES ae  1 Touch BZS icon on 2 Touch is UNLOCK 3 A digital keypad  main menu page  button and hold for 2s  will be shown      10           zJ     How to set the monitor as a Guard Monitor    An indoor monitor can be assigned as Guard Unit indoor monitor  when the  Guard Unit Indoor Monitor answers the call and the conversation with the guard  person starts    Use code 8004 to set the indoor monitor as a guard unit and 8005 to cancel this  function     How to set the slave indoor monitor address    This feature allows a maximum of 4 indoor monitors to act as a group in one system   and must be programmed with the same user code  single family or apartment system    refer to the user code settings for additional information  The first indoor monitor must  be programmed as master and the others must be programmed as slave monitors     The code of 8000 is used to set the master monitor    The code of 8001 is used to set the first slave monitor    The code of 8002 is used to set the second slave monitor    The code of 8003 is used to set the third slave monitor      How to set date and time format    You may set up the sate  amp  time different ways    The code number of 8008 is used to set the date format as month date year  The code number of 8009 is used to set the date format as date month year  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manual de Usuario C16312 (Convertidor Servidor Serial RS232/485  In qualunque momento ш possibile uscire dalla  Intelligent Security and Fire Ltd  Jensen A400HLX Car Amplifier User Manual  取扱説明書 (348.97 KB/PDF)  I.D.C. SOCKET 2.54mm (0.100")  Anleitung  Microwave Leakage Detector  VERNIERN - Velleman    Copyright © All rights reserved. 