1. 2 OUtIiN nnnnnn nanan nnn n nn nn nnn nnn nnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnn 2 Basic FUNCtions 2 Package Contents 4 Part Names and Functions ccna 5 Part Names and Functions 5 LCD Display 6 Installing the Battery z Turning ON the Power Installing the USB Device Driver 8 Windows KPj ceea i a 8 Windows 2000 ares 11 Windows Me aeaee 14 Windows 98 16 If Installation Fails 19 How to Re install cs 19 Connecting the Sensors 20 Connect the Sensor Starting Recording from Main Unit Button 24 Start Recording ns 21 Stop Recording 21 Setting Recording Interval from Main Unit Button 22 Changing the LCD Display Mode from Main Unit Button 23
2. Tab and the Device Manager Window will appear Device Manager Tab USB Recorder1 3 Check to see if USB Recorder 1 is listed under USB Recorder COM 18 If Installation Fails If during USB device driver installation some trouble occurs that results in a failure to install properly the following display will appear in the Device Manager DOU WO ANT Game CORTOS System devices Universal Serial Bus cortrollers z USB Recorder Com Ba ET If this occurs please re install from the USB Device properties How to Re install 1 in the Device Manager Window right click on USB Device under Other Devices to display the USB Device Properties 2 Inthe USB Device Properties Window click on the Re install Driver button to display the Installation Window Follow the directions to install po Beress prive CAL Dese yo USB Fischer Cons Mendectem TAD Corpor Location LEE Dese Device siyin The Greeny kar thee Cie are mcr metabo Code ZEN To var Pee rer for thie dec Che Fist Dies Re install Driver button Quince image Lt the chevice arabii 19 Connecting the Sensors Connect the Sensor To avoid poor connections be sure to push the sensor connector securely into the jack NOTE If a sensor extension cable is being used with the data logger connected by USB to your computer electromagnetic waves may cause large errors in measurements Handling the tem
3. Range 10 95 RH The TR 73U with the sensor included in this package can simultaneously measure and record temperature in a range of 0 to 50 C and humidity in a range of 10 to 95 RH Amount of Recorded Data 8000 readings x 3 channels One channel can record and hold up to 8000 measurement readings At the longest recording interval of 60 minutes recording can continue consecutively for 1 year 10 Months of Operation with just 1 AA Alkaline Battery Our low energy consumption design gives you ten months of continuous operation with only one AA alkaline battery This gives you the freedom to use the data loggers in places where they can be left alone for long periods of time such as in transportation or warehouse NOTE Battery life varies depending upon the type of battery the measuring environment the frequency of communication and the ambient temperature in which it is used Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life Also if the recording interval is less than 10 seconds battery life will be much shorter Battery Life Warning Display When the battery power becomes low a battery life warning signal will appear in the unit s LCD display If the battery power becomes even lower the unit will automatically go into sleep mode in order to protect the data 15 Recording Intervals Select
4. display shows three channels readings alternatively it will show one channel as a fixed display by pressing the button By pressing the button again the LCD display pattern will be set for displaying three channels alternatively If the display has been set for a fixed channel with each pressing of the button the channel display will change Specifications Device Type TR 73U Measurement Items Barometric Pressure Temperature Humidity Number of Measurement 1 Channel 1 Channel 1 Channel Channels with Internal Sensor 750 1100hPa 10 60 C with External Sensor 750 1100hPa 0 50 C 10 95 Responsiveness 4 seconds or 40 seconds Internal Sensor At diria iit iof 1 tui _ Thermal Time Constant Ata baa nye ae pecs 1minute or more 40 seconds Measuring Accuracy with 5 RH 1 5hP A 0 3C Attached Sensor a vorage At 25 C 50 RH M ing Displ SASU AE ARRAY 0 1hPa 0 1 C 1 RH Resolution M lecul Sensor Barometric Pressure Sensor Thermistor ct es Humidity Sensor Recording Interval Select from 15 choices 1 2 5 10 15 20 and 30 seconds 1 2 5 10 15 20 30 and 60 minutes Recording Capacity 8000 Readings x 3 channels Recording Modes Endless Mode Overwrite oldest data when capacity is full One Time Mode Stop recording when capacity is full Power AA alkaline battery LR6 x 1 Battery Life About 10 months 1 Interface USB Communication Weight of Ma
5. 9 After completing installation click the Finish button Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 12 Checking After Connecting Ms Open the Control Panel and double click on System the System Properties will be displayed 2 Click the Hardware Tab and click the Device Manager button in the Device Manager Area Hardware Tab Device Manager 3 Inthe Device Manager Window check to see if USB Recorder 1 is listed under USB Recorder COM USB Recorder1 13 Windows Me 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Add New Hardware Wizard will automatically open 5 Check Automatic search for a better driver Recommended and click the Next button to begin installation 6 After completing installation click the Finish button Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 14 15 Checking After Connecting 1 Open the Control Panel and double click on System
6. Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product Some of our products which come under the category of stategic goods in foreign trade law need the permission of the Japanese government to be exported outside of Japan This User s Manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair carefully FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment genera
7. Specificat oNS 24 Optional Accessories 25 Cautions about using the Sensors Handling the temperature humidity sensor The temperature humidity sensor should probably be changed after a period of about one year After removing the sensor from its package please change the temperature humidity sensor after one year s usage During use the temperature humidity sensor will accumulate impurities dirt on the surface of the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 5 to 25 C and a humidity of below 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the stickers shows abnormality you should change the old sensor to a new one immediately CON Wetness Detection Sticker gt 11 lt Temperature Detection Sticker Wetness Detection Sticker Informs you that the sensor has been wet Normal Abnormal Under normal conditions m iusi 2424 Under abnormal conditions it will black dots will appear on a ns white 1 turn to red Te
8. Thermo Recorder TR 73U Copyright 2006 T amp D Corporation All rights reserved 2006 12 16004484011 Notice about this User s Manual In order to properly use this product please carefully read this manual before using T amp D Corporation accept no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corportion Microsoft and Windows are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company Please follow the safety precautions carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended Specification design and other contents outlined in this manual are subject to change without notice One screen messages in this manual may very slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors or unclear explanations in this manual T amp D
9. ange recording interval settings from the lt INTERVAL gt button on the front of the TR 73U main unit During recording or while waiting for a programmed recording to start via the provided software there are not settings to be made Thermo Recorder TR 73U lt INTERVAL gt button 1 Press in the lt INTERVAL gt button on the front of the device until the recording interval appears in the display 2 With each pressing of the lt INTERVAL gt button the recording interval time will change Press until the desired setting appears Recording Interval 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60 minutes 15 seconds 15 minutes DATA ENDLESS DATA ENDLESS Can ic ic O25 I 3 When the desired recording interval appears stop pressing the lt INTERVAL gt button Within a few seconds the current measurement readings will return to the display and the setting will be finished By pressing the lt INTERVAL gt button during recording or while waiting for a programmed recording to start via the provided software the currently set recording interval will be displayed 22 23 Changing the LCD Display Mode from Main Unit Button You can make or change the LCD display settings from the lt DISPLAY gt button on the front of the TR 73U main unit lt DISPLAY gt button 1 By pressing the lt DISPLAY gt button on the front of the unit you can change the screen display 2 Ifthe LCD
10. ealer customers should contact the nearest authorized T amp D sales representative A list of these can be found on the company s website www tandd com or it can be obtained by contacting TandD US directly 4 This limited warranty statement gives the customer specific legal rights The customer may also have other rights which vary from state to state in the United States from province to province in Canada and from country to country elsewhere in the world To the extent this limited warranty statement is inconsistent with local law this statement shall be deemed modified to be consistent with such local law 5 For further information relating to product repair or replacement or for other service questions after the termination of the warranty period customers should contact their local authorized T amp D sales representative T amp D corporation
11. from 15 recording intervals from 1 second to 1 hour to meet your needs Select from 2 Recording Modes One time Mode When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded readings reaches 8000 the oldest data readings will be overwritten and recording will continue Backup Function When battery power becomes low a battery life warning signal will appear in the unit s LCD display and if the battery power becomes even lower the unit will automatically go into sleep mode in order to protect the data In sleep mode all normal operations will stop and it will become impossible to switch on the power of the main unit NOTE If the main unit remains in sleep mode for about 1 month without a change of battery or if the battery is left out of the unit for more than 2 minutes all recorded data will be lost Current Readings Monitoring Display With our exclusive software you cannot only monitor the current measurements at a set interval but can view those measurements in a continually changing graph You can simultaneously display the current measurements and corresponding graphs for the number of units you have connected Adjustment Function By entering the adjustment values beforehand with the provided software it is possible to view and record the adjusted measurement values There are two methods of adjust
12. in Unit About 62 g including one AA battery Dimensions H55mm x W78mm x D18mm Working Environment for Main Unit Temperature 10 to 60 C Humidity under 90 RH without condensation Accessories included in package Temperature Humidity sensor TR 3100 x 1 AA alkaline battery LR6 x 1 USB communication cable cable length1 5m Software x 1 User s Manual Warranty x 1 1 Battery life depends upon the measuring environment communication frequency recording interval and quality of the battery being used Also if the recording interval is less than 10 seconds battery life will be much shorter It is possible to change the battery during recording 24 Optional Accessories TR 07K2 Wall Attachment Wall Attachment ts 3 Included HL screws x 2 double sided tape x 1 US 15C USB Communication Cable Cable Length about 1 5 m LE T amp D CORPORATION http www tandd co jp 5652 169 Sasaga Matsumoto City Nagano 399 0033 Japan Tel 81 263 27 2131 Fax 81 263 26 4281 E mail overseas tandd co jp Office Hours Monday to Friday 9 00 12 00 13 00 17 00 Thermo Recorder TR 73U User s Manual Published by T amp D CORPORATION copyright 2006 T amp D Corporation Alll rights reserved This is printed on 100 recycled paper Thermo Recorder TR 73U Warranty Customer s name Address Phone No Dealer s name Address Phone No Gua
13. ment adjusting by one point or adjusting by two points Adjustment for differences will be based upon the following simple equation Y aX b X equals the measured value and Y equals the value after adjustment Package Contents Thermo Recorder TR 73U x 1 T amp D Recorder for Windows Temperature Humidity Sensor TR 3100 x 1 Software CD ROM x 1 User s Manual Warranty x 1 Software User s Manual x 1 3 USB Communication Cable AA Alkaline battery x 1 US 15C x 1 Part Names and Functions Part Names and Functions FRONT Thermo Recorder TR 73U lt DISPLAY gt lt INTERVAL gt lt REC STOP gt button button button DISPLAY Pressing this button will change the LCD Display Mode INTERVAL Pressing this button will display the currently set recording interval REC STOP Pressing this button will start or stop recording LEFT SIDE RIGHT SIDE Sensor Jack USB Cable Jack P Power Switch Serial Cable Jack 1 1 Not supported in TR 73U LCD Display Lf CE3 BATA com ENDLESS tt 20 2000 nes Recording Mark The recording condition will appear ON Recording in progress BLINKING Waiting for programmed start Data Capacity Scale After every 2000 readings the scale will be marked from left to right COM Mark This will appear when data is being sent or received ON USB cable is connected BLINKING In communication with co
14. mperature Detection Sticker Informs you that the sensor measured a temperature measurement over 60 C Normal Abnormal Under normal conditions E the number 60 will lightly appear on a pinkish white background Under abnormal conditions the 60 number 60 will clearly appear on a red background About Thermo Recorder TR 73U Outline TR 73U Thermo Recorder is a data logger capable of measuring displaying and recording temperature humidity and barometric pressure data TR 73U has a total of three channels one temperature one humidity and one barometric pressure channel The data recorded into the TR 73U units can then be downloaded quickly via USB cable to your computer whereby with our exclusive software you can easily process the data into graphs tables save to files and or print it out Moreover it is possible to connect more than one unit at the same time Basic Functions Barometric Pressure Measuring Range 750 1100hPa The TR 73U with the internal barometric pressure sensor can measure and record in a range of 750 to 1100 hPa Temperature Measuring Range 40 110 C The TR 73U with the sensor included in this package can measure and record ina range of 0 to 50 C but by purchasing one of our optional sensors it is possible to measure and record in the wider range of 40 to 110 C Please take a look at our full range of optional sensors to find one to match your application Humidity Measuring
15. mputer Recording Mode One time Mode When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded readings reaches 8000 the oldest data readings will be overwritten and recording will continue Battery Life Warning Signal When the battery power becomes low a mark will appear on the LCD of the main unit If the battery power becomes even lower SLP will appear and normal operations will stop Please change the battery as soon as the Battery Warning Mark appears Unit of Measurement The unit of the measurement for the display will appear Measurements and Messages Area Current measurements or operational messages such as FULL or SLP will appear Installing the Battery 1 Remove the battery cover form the back of the unit 2 Insert 1 AA alkaline battery making sure that the and are in the correct direction Always use a new battery 3 Replace and close the battery cover Changing the Battery 1 When battery power becomes low a battery life warning signal will appear in the unit s LCD display If at this time you change the battery recording will continue uninterrupted and all data will be saved for downloading 2 Ifthe battery is not changed and power becomes even lower SLP will appear in the LCD display The unit will automatically go into sleep mode in order
16. normal conditions the J number 60 will lightly appear g number 60 will clearly appear on a on a white pink background red background 20 Starting Recording from Main Unit Button By pressing the lt REC STOP gt button on the main unit you can start a recording session immediately If you wish to make changes to the device name channel name recording mode or to any other recording conditions you must make those settings by connecting the device to your computer Thermo Recorder TR 73U lt REC STOP gt button Start Recording Press in the lt REC STOP gt button on the front of the unit until the REC mark appears in the display When displayed recording has begun REC mark REC DATA com ENPLESS lights up ci 2 2 2 h ah 0 8 hPa NOTE By starting a new recording session all data currently saved in the unit will be erased Even if the unit is waiting for a programmed recording to start via the provided software by pressing the lt REC STOP gt button until the REC mark appears you can start a new recording session immediately Stop Recording You can stop a recording session by pressing the lt REC STOP gt button until the REC mark disappears from the display When it has disappeared recording has stopped REC mark p DATA com ENDLESS disappears rm h ah ah ah hPa 21 Setting Recording Interval from Main Unit Button You can make or ch
17. not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there Checking After Connecting 1 Open the Control Panel and double click on System the System Properties will be displayed 2 Click the Hardware Tab and click the Device Manager button in the Device Manager Area 3 Inthe Device Manager Window check to see if USB Recorder 1 is listed under USB Recorder COM gt oF rada e tiered y mue md ee perg wae ren ret etait Le LISE LT LE USB Recorder1 10 Windows 2000 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Found New Hardware Wizard will automatically open 5 By clicking the Next button a window will open where you can choose how you wish to find the driver file Welcome to the Found New Hardware Wizard THe vizand helps pou atad device drives Jor a hasaa dence To cordes chick New 11 6 Check Search for a suitable driver for my device Recommended and click the Next button me teow me gr be ete mire tne mae te Dd eens A 8 Click Next to start the installation
18. on or other damage incluing malfunction Areas exposed to excessive vibration This may cause injury malfunction damage or loss of proper electrical contact Areas near fire or exposed to excessive heat This may cause damage including malfunction and deformation Areas prone to smoke duct and dirt This may cause damage including malfunction vii Cautions about using the Sensors Cautions about using the temperature humidity sensor TR 3100 gt be The sensor can measure temperature within the range of 0 to 50 C and humidity within the range of 10 to 95 RH Only use the sensor within these ranges If extremely severe temperature changes occur the humidity measurements may appear abnormal Once the sensor s temperature becomes stable the measurements will return to normal This sensor is not waterproof Do not get wet When measuring with the temperature humidity sensor in an environment of 0 to 50 C and less than 30 RH the measurements may sometimes fluctuate This is not abnormal Table of Contents Notice about this User s Manual FCC Compliance Statement for American Users ii EEE ii Safety Precautions and Instructions iii To ensure safety be sure to obey all of the following warnings iii Explanation of SymbolS iii About Thermo Recorder TR 73U
19. perature humidity sensor The temperature humidity sensor should probably be changed after a period of about one year After removing the sensor from its package please change the temperature humidity sensor after one year s usage During use the temperature humidity sensor will accumulate impurities dirt on the surface of the sensor causing the sensor s accuracy and sensitivity to decrease If the sensor is being used in a bad environment smoky or dusty places it may be necessary to change the sensor sooner When the temperature humidity sensor is not being used please place it in the attached vinyl bag with the drying agent included and store it in a cool dark place with a temperature of between 5 to 25 C and a humidity of below 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the stickers shows abnormality you should change the old sensor to a new one immediately Wetness Detection J K Temperature Sticker Detection Sticker mo c Wetness Detection Sticker Informs you that the sensor has been wet Normal Abnormal Under normal conditions black dots will appear on a white background Under abnormal conditions the background will turn to red Temperature Detection Sticker Informs you that the sensor measured a temperature measurement over 60 C Normal Abnormal Under normal conditions the Under ab
20. rame before touching the unit Static electricity may cause not only damage to the unit but may cause breaks in or a loss of data If the unit will not be used for period of time for safety reasons please remove the battery If left in the unit it may leak and lead to malfunctioning Please take extra caution when plugging in and pulling out the USB plug while another USB device such as CD RW HDD is in operation It may cause problems to your CD RW or other device CAUTIONS We shall not guarantee the operation of our device if you have connected it to your computer using a USB hub or a USB extension cable Batteries used under low pressure conditions may leak and cause a malfunction 2010919 gt S Please do not insert your fingers or any foreign objects into any of the devices jacks Do not use any other batteries than those that are specified in this User s Manual It may cause a fire or other trouble including malfunction Do not use or store the Thermo Recorder in any of the following places Doing so may cause electrocution fire and or other adverse effects to the device and or your computer Areas exposed to direct sunlight This will cause the inside of the device to become overheated and may cause fire deformation and or other damage including malfunction Areas prone to strong magnetic fields This may cause damage including malfunction Areas exposed to water leakage This may cause electrocuti
21. rantee period 12 months from date of purchase Date of purchase OZ O O SSS SOS SyS Statement of Limited Warranty 1 This product is warranted to be free from defects in materials and workmanship for a period of one 1 year following the date of purchase Should the product fail to operate per specification in normal use during this period T amp D will repair the unit or provide a replacement free of charge T amp D will not accept returns for any reason other than defects during the warranty period and will not accept any product that has been misused dropped abused or inappropriately used or mistreated at any time 2 This warranty is strictly limited to repair or replacement in kind for defective product T amp D makes no other warranty either express or implied and will not accept liability beyond the remedies stated herein Specifically T amp D will not accept liability for direct indirect special consequential or incidental damages arising from the use of this product 3 Customers wishing to submit a defective product for repair or replacement during the warranty period should first contact the dealer from whom it was originally purchased After receiving a return authorization the defective product should then be packaged along with a description of the difficulties being experienced proof of purchase and all included accessories and materials and returned it to the dealer In the event of difficulty contacting the original d
22. shed by the FCC for this equipment You are cautioned that changes or modifications not expressly approved by party responsible for compliance could void your authority to operate the equipment Safety Precautions and Instructions To ensure safety be sure to obey all of the following warnings The following items should be strictly obeyed for the safe usage of this unit and for protecting yourself and other people from bodily harm and or damage to property To ensure the proper use of our product please read the following carefully and fully understand the contents Explanation of Symbols Explanation of Warning Symbols These entries are actions that absolutely under no circumstance should be taken The taking of such an action may cause serious personal physical damage or death These entries are actions that if taken may lead to physical injury or CAUTION damage to persons or things Explanation of Picture Symbols Denotes an important warning or caution Denotes a forbidden action Inside or near the symbol will appear another symbol giving details Ex stands for DO NOT TAKE APART Denotes an action that you must take 80 D 0e DANGERS Do not take apart repair or modify the main unit Doing so may cause fire or electrocution If water or a foreign body enters into this unit immediately remove the batteries and stop using Continued use may cause fire or electrocution Do not use
23. tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Warning This equipment has been verified to comply with the limits for a Class A personal digital device pursuant to Subpart B of Part 15 of FCC Rules Only peripherals computer input output devices terminals printers etc certified or verified to comply with the Class A or B limits may be attached to this equipment Operation with non certified or non verified personal computer and or peripherals is likely to result in interference to radio and TV reception The connection of a non shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits establi
24. the System Properties will be displayed 2 Click the Device Manager Tab and the Device Manager Window will appear Device Manager Tab USB Recorder1 3 Check to see if USB Recorder 1 is listed under USB Recorder COM Windows 98 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Add New Hardware Wizard will automatically open 5 By clicking the Next button a window will open where you can choose how you wish to find the driver file 16 6 Check Search for the best driver for your device Recommended and click the Next button 7 Check Specify a location and click the Browse button Select the Device Driver in the CD ROM drive and click Next Browse button 8 Click Next to start the installation 9 After completing installation click the Finish button Caution If the Driver is not automatically detected please search by specifying the place as CD ROM Device Driver and install manually from there 17 Checking After Connecting 1 Open the Control Panel and double click on System the System Properties will be displayed 2 Click the Device Manager
25. the software T amp D Recorder for Windows the USB Device Driver will also be copied to your hard disc So even if you do not have the CD ROM but have already installed T amp D Recorder for Windows you can easily install the USB Device Driver Windows XP 1 Turn on your computer and open Windows 2 After Windows has been completely started up connect the supplied USB cable to a USB port on your computer 3 Insert the attached CD ROM in the CD ROM drive If the Installation Window opens close it 4 By connecting a data logger to the USB cable already connected to your computer the Found New Hardware Wizard will automatically open Welcome to the Found New Hardware Wizard Th o wiza heta pou inetd octane bor USB Device 0 pour bandmate come with an matailehen CO gt oi llopos dink inseri A aow What do pou ward fre mardis da iroalife c ra asrveicay Fiecreverded Olretadar att or pect cain cran Dkk New 1000 Please note that when using Windows XP SP2 or above the following window will appear Click No not this time and then click Next Completing the Found New Hardware Wizard The ard ap rived etage scies ba k rdet k Frish da ciae the ed Ca 5 By checking Install the software automatically Recommended and clicking Next the software will automatically be installed 6 After completing installation click the Finish button Caution If the Driver is
26. this unit in wet or humid places such as a bathroom Store main units sensors batteries and communication cables out of the reach of children It is dangerous to touch or swallow batteries If any smoke or strage smells are emitted from the unit immediately remove the batteries and stop using Continued use may cause fire or electrocution This device is designed to measure and record temperature and humidity Do not use it for any other purpose than to measure and record temperature and humidity gt ee P P O OO CAUTION This unit is not water resistant If the unit gets dirty wipe it with a clean cloth and a mild detergent Do not expose the unit to harmful gases or chemicals It may cause corrosion and or other danger to the unit and to people handling the unit Do not use batteries other than specifies Doing so may cause fire or damage Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss Condensation may occur if the units is moved from one environment to another where the difference in temperature is great Use the unit in an environment where the ambient temperature is great Use the unit in an environment where the ambient temperature is from 10 to 60 C and the humidity is 90 RH no condensation or less To prevent damage to the unit from static electricity remove static electricity from your body by touching metal aroung you door knob window f
27. to protect the data and all normal operations will stop If you change the battery at this point it is still possible to download all saved recorded data 3 Ifthe battery is further left unchanged the display will automatically shut off If all battery power is lost all data will be lost as well NOTE If a unit is left without a battery for more than 2 minutes all data will be lost so please work quickly when changing the battery Turning ON the Power 1 By holding in the POWER switch at the left side the unit will turn on Turning OFF the Power By holding in the POWER switch the unit will turn off During recording the power cannot be turned off Please stop recording first and then turn off the power Even if the power has been turned off the recorded data will be saved However if the battery power is totally lost all data will be lost so please download data as soon as possible to avoid losing any necessary data Installing the USB Device Driver You will need to install this driver in order to use the device with a USB cable and Windows The USB device driver must be installed for communication via USB between your computer and a TR 73U Thermo Recorder After installing the USB device driver your computer will be able to detect and recognize TR 73U devices that have been connected with a USB cable a fi To the Computer To the Main Unit When installing