Home
USER MANUAL
Contents
1. running if the network status indicator is 64ms On 300ms Off and users can control data transmission via AT command SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 7 of 8 SG361 GSM GPRS Module 3 3 INSTALLATION It is fixed by two M3 screws when installed and the center distance is 61 5mm The overall dimensions please refers to as following LED Status Description off Not work 64ms On 800ms Off Notregistered the network 64ms On 3000ms Off Registered to the network 64ms On 300ms Off GPRS communication is ok Status RS232 SG361 GSM GPRS MODEM DC SUPPLY 8V 32VDC Smartgen SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 8 of 8
2. Smartgen SG361 GSM GPRS Module USER MANUAL Smartgen Technology YON Ko FA F Chinese trademark S m al rtg e n English trademark Smartgen make your generator smart Smartgen Technology Co Ltd No 28 Jinsuo Road Zhengzhou City Henan Province P R China Tel 86 371 67988888 66 3 1 6 981888 86 37 1 67991553 86 371 67992951 86 371 67981000 overseas Fax 0086 3 1 6 992952 Web http www smartgen com cf http www smartgen cn Email sales smartgen cn All rights reserved No part of this publication may be reproduced in any material form including photocopying or storing in any medium by electronic means or other without the written permission of the eopyright holder Smartgen Technology reserves the right to change the contents of this document without priorNotice lf colors of actual products are different from those mentioned within this manual please take the actual product as the standard Software Version 2014 02 23 Original release SS ee SG361 GSM GPRS Module Contents Ts ZONE NEN a TEN 4 2 PRODUCT FEATURE wn cocci ccc cece ccc ccccccccccccucuucuecuccuuauuaueeecauvauusnusueuauusnnnnes 5 2 1 TECHNICAL PARAMETERS c cccccccccecceccececceccecceceeceecesuesnesueaueaes 5 2 2 STIRUGCTUWREz8 ALAGA GEL GA 6 3 TYPICAL APPLICATION AND INSTALLATION STEPS nnn 7 3 1 TYPICAL APPLICATION aanne 3 2 INSTALLATION STEPS ccccccccccccccscescesus
3. artgen 1 TERMINAL TX Sending end connect to RX of RS232 interface RX Receiving end connectto TX of RS232 interface GND Ground wire connect to ground wire of RS232 interface B Positive power supply voltage range 8 32 V B Negative power supply 2 NETWORK STATUS INDIGATOR RED DO 64ms On 800ms Off Not registered to the network 64ms On 3000ms Off Registered to the network 64ms On 300ms Off GPRS communication is ok 3s SIM CARD SLOT Drawer type card slot used for installing the SIM card 4 ANTENNA INTERFACE Fit with standard SMA interface and 500 matching impedance Connect the antenna to SMA interface and then tighten the screws SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 6 of 8 SG361 GSM GPRS Module 3 TYPICAL APPLICATION AND INSTALLATION STEPS 3 1 TYPICAL APPLICATION Module 3 2 INSTALLATION STEPS 1 INSERT SIM CARD The drawer of the SIM card will pop up after the yellow key is pressed using needle Insert the SIM card into the slot and then close the drawer SMA Antenna Interface Extract Card SIM Card Slot 2 INSTALL ANTENNA Connect the antenna to SMA interface and then tighten the screws 3 COMMUNICATE WITH CONTROLLER Details connection way pleases refer to Chapter 3 1 TYPICAL APPLICATION 4 CONNECT POWER LINE The power should not less than 5W to ensure the operation is smoothly as the power supply voltage of the SG361 module is DC 8 32 V The system is normal
4. euscueaeeaees 3 3 INSTALLATION S Ka SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 3 of 8 SG361 GSM GPRS Module 1 OVERVIEW SG361 GSM GPRS Module has SMS Short Message Service function and GPRS data transmission function S amp SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 4 of 8 SG361 GSM GPRS Module 2 PRODUCT FEATURE 2 1 gt Vv Y VV VV Vv Vv Vv vv vv vv TECHNICAL PARAMETERS Power supply DC 8 32 V Four frequency GSM GPRS module Working frequency GSM GPRS 850 900 1800 1900MHz Control GSM 07 07 07 05 via AT command GPRS multi slot class 10 8 GPRS mobile station class B GPRS class 10 maximum 85 6 kbps downstream rate SMS text mode PDU mode Antenna Interface 500 SMA Female SIM card 1 8 3V Automatic detection Drawer type card slot Power supply Interface pluggable terminals RS232 Communication interface TX RX GND Working Temperature 30 70 C Storage Temperature 30 80 C Humidity 95 No condensation Case Dimensions mm 89x66x26mm L W H Weight 151g SG361 GSM GPRS Module Version 1 0 2014 02 23 Page 5 of 8 SG361 GSM GPRS Module 2 2 STRUCTURE LED Status Description Off Not work 64ms On 800ms Off Notregistered the network 64ms On 3000ms Off Registered to the network 64ms On 300ms Off GPRS communication is ok Status RS232 SG361 GSM GPRS MODEM vo gt DC SUPPLY 8V 32VDC Sm
Download Pdf Manuals
Related Search
Related Contents
fr - Leroy Somer INSTRUCTION SHEET for HMISTO5pp and Simplicity Manual Descripción: FOTOCOPIADORA Código: BM16 Lote: 25 Año: 2009 SERVICE MANUAL KDC-W4044UA/W4044UAY KDC 取扱説明書 - 森長電子 KDDI との業務委託契約に伴う2次店募集と inflation station™ 500 12v multi-purpose air Copyright © All rights reserved.
Failed to retrieve file