703171 Rev A - Control Unit User`s Manual, GR2, Veterinary.indd
Contents
1. the instructions for use that accompanied that battery pack for usage details Warning Position the Control Unit to minimize the risk of tripping over the Control Unit Connector Hose or power cord
2. IEC 60601 1 2 2001 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving device e Increase the separation between the equipment e Connect the equipment into an outlet on a circuit different from that to which the other device s are connected e Consult the manufacturer or field service technician for help Powered by Direct Current Type BF Applied Parts Attention Consult accompanying documents before use a ee DESCRIPTION OF DEVICE ee Power Cord Packet Wrap Game Ready System The following items are included in your Game Ready System a Control Unit an AC Adapter a Power Cord and a Welcome Packet In addition to these items a Hose Heat Exchanger and Sleeve are required to operate the system These items may be purchased seperately Volume Pr
3. USE e Phenolic based disinfectants Such as Amphy e Any solvent based cleaners on the Connector Hose Doing so will damage the plastics and will void your warranty e Abrasive materials to clean the Connector Hose Doing so will damage the plastics and will void your warranty e Any petroleum based lubricants on the Connector Hose Doing so will damage the o rings and will void your warranty If lubrication is required the use of silicone spray is recommended The following silicone sprays have been successfully tested with our o rings e DuPont Teflon Silicone Spray DuPont Part DS0614101 e 3M Silicone Spray 3M Part 62 4678 4930 3 e 500 PSI Silicone Pump Spray Game Ready Part 302056 WRAPS Gently remove Heat Exchanger from the Sleeve Hand wash the sleeve in cold water using a mild detergent or antibacterial soap Do not use fabric softener Hang to dry If needed the external surface of the Heat Exchanger may be cleaned by wiping down with commercial non bleach cleaning wipes or hand washed using a very small amount of mild detergent or antibacterial soap DO NOT MACHINE WASH Periodically run Hydrogen Peroxide through your Game Ready System to keep the interior of your wrap clean Refer to the Wrap Use Guide for more specific Wrap care instructions INDICATIONS FOR USE e Follow the recommendations of your veterinarian The Game Ready System combines cold and compression therapies It is intended to prevent injuries treat
4. by the following icons JO BUTTONS Power Use this button to turn the Control Unit on and off Program Use this button to select one of the available Programs or to return to Manual Mode See page 15 in this manual for more information on Programs Play Pause Use this button to start or pause a treatment or to stop Add Time Use this button to add time in Manual Mode does not work in Program Mode You can add up to 90 minutes Treatment must be paused in order to add or subtract time Subtract Time Use this button to reduce time in Manual Mode does not work in Program Mode You can subtract up to 90 minutes Treatment must be paused in order to add or subtract time Pressure Selection Use this button to select one of four pressure settings No Pressure Low Pressure 5 15 mmHg Medium Pressure 5 50 mmHg and High Pressure 5 75 mmbHg Pressure selection is not available in Program Mode Treatment must be paused to change pressure settings Volume Use this button to select the option of sound or no sound Alarms will still sound C F Button Use this button to select either Celsius or Fahrenheit on the temperature display Backlight Use this button to turn the backlight on or off CME O O POE Adjusting Temperature The Control Unit cools the Wrap by pumping water from the ice box into the Wrap therefore the temperature of the Wrap will never be colder than the water in the
5. ice box If the knob is turned to three 3 snowflakes the Control Unit will provide the coldest possible therapy based on the temperature of the water in the ice box Turning the knob towards one 1 snowflake will provide less cold therapy Note The unit should always be started on full cold 3 snowflakes and run that way for at least two minutes The user can then adjust temperature as desired Adjusting Temperature Temperature Knob a S Less Cold More Cold ssr Full Cold Turn knob clockwise for more cold therapy Turn knob counter clockwise for less cold therapy DISPLAY Status bar Vol 1d Manual y a Program Pause EE Play P When the System is running in Program Mode When the System is running in Manual Mode Vol q Off Mute 1 On Manual SS ndicates selected mode Program Pause EE ndicates unit is paused Play P Caer Error A ndicates an error See troubleshooting pages 18 19 for error codes Sleep O ndicates sleep mode time Battery mam ndicates remaining battery capacity Temperature Sleep time count down bars C G ota C3 ndicates unit is playing Average Wrap Temperature ndicates an estimate of the average temperature of the Wrap averages the temperature of the water going into and out of the Wrap Coldest Wrap Temperature ndicates an estimate of the temperature of the water going into the Wrap from th
6. GAME G2 READ Y VETERINARY CONTROL UNIT User s Manual MODEL 550450 User s Manual also available online at www gamereadyveterinary com WARRANTY LIMITATIONS OF LIABILITY COOLSYSTEMS RESPONSIBILITY UNDER THIS OR ANY OTHER WARRANTY IMPLIED OR EXPRESS IS LIMITED TO REPAIR OR REPLACEMENT AS SET FORTH ABOVE THESE REMEDIES ARE THE SOLE AND EXCLUSIVE REMEDIES FOR ANY BREACH OF WARRANTY COOLSYSTEMS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR UNDER ANY OTHER LEGAL THEORY INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWNTIME GOODWILL AND DAMAGE TO OR REPLACEMENT OF EQUIPMENT AND PROPERTY SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION WARRANTY REGISTRATION Please complete the Warranty Registration for both the Game Ready Control Unit and the Wraps online at www gamereadyveterinary com You must register within 30 days from the date of purchase in order to receive warranty service You will need the following information to complete your Warranty Registration The Control Unit s model number REF and its serial number SN These numbers are located on the label on the bottom of the Control Unit Simply go to
7. Game Ready Customer Service from the U S call toll free at 1 888 426 3732 from outside of the U S call 001 510 868 2100 You must have returned the Warranty Registration card to CoolSystems within thirty 30 days from the date of purchase to qualify for warranty service If you qualify for warranty service from CoolSystems you will be issued a Returned Material Authorization RMA number When you return the Game Ready Control Unit to CoolSystems you must write the RMA number on the outside of the package CoolSystems will not accept returned Game Ready Control Units without an RMA number on the package If you return the Game Ready Control Unit to CoolSystems you must assume the risk of damage or loss during shipping You must use the original packaging or the equivalent CoolSystems may require you to verify in writing that you are the original purchaser of the Game Ready Control Unit CoolSystems may elect to replace or repair the Game Ready Control Unit with either a new or reconditioned product The returned product shall become CoolSystems property upon receipt The replacement Game Ready Control Unit is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period THIS WARRANTY IS NOT TRANSFERABLE WARRANTY LIMITATIONS AND EXCLUSIONS THESE WARRANTIES REPLACE ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
8. Hose Not included A Game Ready Carry Bag e A Game Ready supplied battery and charger 17 CLEANING CONTROL UNIT The exterior of the Control Unit and the visible interior surfaces of the ice box can be cleaned with a soft cloth and one of the following cleaning agents e Mild detergent e 5 Bleach solution e 6 Hydrogen peroxide e 70 Isopropyl alcohol DO NOT USE e Phenolic based disinfectants such as Amphyl e Quaternary Ammonium such as Virex e Any solvent based cleaners on the Control Unit Doing so will damage the plastics and will void your warranty e Abrasive materials to clean the Control Unit Doing so will damage the plastics and will void your warranty Caution The Control Unit is not a waterproof device Do not apply a direct stream of any liquid onto the Control Unit submerge the Control Unit or allow any liquid to pool on the surface of the front panel of the Control Unit Procedure e Follow the manufacturer s instructions and precautions for the cleaning agent you select e Apply the selected cleaner to a soft cloth and wipe down all surfaces of the Control Unit e Allow the Control Unit to dry thoroughly before storing it in the bag e The Control Unit should be cleaned as needed CONNECTOR HOSE The Connector Hose can be cleaned using a soft cloth and one of the following e Mild detergent e 70 Isopropyl alcohol We do not recommend the use of Quaternary Ammonium such as Virex DO NOT
9. MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE COOLSYSTEMS MAKES NO EXPRESS WARRANTIES BEYOND THOSE STATED HERE COOLSYSTEMS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THIS LIMITATION MAY NOT APPLY TO YOU ALL EXPRESS AND IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD NO WARRANTIES APPLY AFTER THAT PERIOD SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THIS LIMITATION MAY NOT APPLY TO YOU TABLE OF The Game Ready Difference CONTENTS Indications for Use General Warnings and Precautions General Warnings and Precautions Device Classification Description of Device Using Your Game Ready System Cleaning Maintenance Storage Specifications Accessories Troubleshooting Warranty TROUBLESHOOTING ERROR WHAT DOES IT MEAN Under Pressure The Control Unit can t reach its target maximum compression This often indicates that there is a leak in the pneumatic compression circuit either in the Connector Hose Wrap or Control Unit Or it may occur because the hook and loop fastener on your Wrap has worn out WHAT CAN DO e Make sure the Wrap is tightly applied e Try using a different Wrap and Hose to is
10. e ice box Displays the amount of run time remaining Run time count down bars Displays the amount of sleep time remaining Displays the amount of run time remaining When selecting Displays pressure Off ue off Low Med High Ld tl Off Low Med High J M Off Low Med Righ NNNINEURREEEE USING YOUR GAME To operate your Game Ready System you need e A Control Unit filled with ice and water e A Game Ready supplied power supply eA Connector Hose Sold seperately e A Wrap a Heat Exchanger and Sleeve Sold seperately Notes e The Wrap is comprised of an inner Heat Exchanger and an outer Sleeve The combination of Sleeve and Heat Exchanger is referred to throughout this manual as a Wrap e The Game Ready Control Unit should be placed on a stable surface such as the floor or a table during use e Please note that using the System in an environment with a high ambient temperature a program Pressure of Low Med ef Average Wrap bd v v bd Temp 3 Volume cc C DONN G 50 10 Manual T 45 7 0 Program ws Pause Ml ae Play gt m Sleep Run Coldest Wrap Time Time Temp Displays amount of Displays amount of time unit will sleep time unit will run Pressure Low Med High READY SYSTEM may affect its ability to provide adequate cooling or may limit the ice life e f you will be using the System with a Game Ready supplied battery pack please consult
11. essure Indicator Pressure Backlight a Average Wrap Temperature Average gt Wrap Temp Power Program Temperature Knob Play Pause Sleep Run Coldest Time Time __ Wrap Temp Coldest Wrap C F Celsius Fahrenheit Temperature Subtract Add Time Time Manual Mode MODES OF OPERATION Manual Mode The System defaults to this mode and allows the user to adjust time and pressure settings Program Mode This mode allows the user to choose one of six programs that provide treatment for a set time then sleep no treatment for a set time continuously at a specific pressure setting USING YOUR GAME READY SYSTEM s34 Place the Control Unit in the location where you plan to use it The Control Unit should only be used in the upright orientation as shown The Control Unit will leak if placed on its side Connect the AC Adapter to the Control Unit and the grounded electrical outlet The power indicator light orange color on the Control Unit should illuminate If it does not illuminate check to make sure that the AC Adapter is firmly connected in all locations and that the outlet is receiving power If necessary try an alternate outlet or power supply If the light is still not illuminated and the Control Unit will not turn on please contact Game Ready Customer Service from the U S call toll free at 1 888 426 3732 or from outside of the U S call 001 510 868 2100 Note The Control Unit should be powered up
12. f and on circuit on start up again without a Wrap connected Control Unit will not turn on Check to make sure the AC Adapter is securely plugged into a working electrical outlet Press the power button again If the orange LED on the control panel is illuminated but the Control Unit will not turn on call 1 888 426 3732 from the U S and from outside the U S dial 001 510 868 2100 If no orange or green light is illuminated check that the electrical outlet has power 19 Z rs TROUBLESHOOTING WHAT DOES IT MEAN Air Pressure Sensor The Control Unit has detected a problem calibrating the pneumatic compression circuit on start up Self Test Error Air Pump The Control Unit has detected an electronic problem in the air circuit on start up WHAT CAN I DO e This is most likely to occur if you have restarted the System with an inflated Wrap attached e Detach the Wrap and try again e Disconnect the Wrap from the Control Unit e Turn the Control Unit off and on again without a Wrap connected gt D Co 2 Dry Pump The Control Unit has detected a dry pump In order to prevent possible damage to the fluid pump the unit will stop therapy e Make sure there is water in the ice box e Verify that the ice box filter is not clogged e Make sure there are no kinks in the Wrap or Connector Hose e Turn the Control Unit off and on again e Disconnect and reconnect the hose from the Con
13. l device Handle it with the same care as you would a laptop computer Do not drop it kick it or otherwise abuse it unnecessarily Such abuse will void all Game Ready warranties Do not place the AC Adapter or battery pack inside the ice box for storage or transport In addition to the precautions listed above additional warnings and safety precautions are posted throughout this manual Read and carefully follow these instructions prior to operating the System USING YOUR GAME READY SYSTEM You can choose to operate in either Manual Mode or Program Mode Manual Mode allows you to adjust time and pressure settings Manual f T Program Mode allows you to choose one of six programs that provide 8 treatment for a set time then sleep no treatment for a set time continuously at a specific pressure setting The unit will default to anual Mode Program Manual Mode Set the time by pushing the buttons from 4 pressure settings No pressure Low Pressure 5 15 mmHg Set the pressure by pushing the pressure button You can select O Medium Pressure 5 50 mmHg High Pressure 5 75 mmHg Program Mode Push the program button to enter Program Mode In Program Q Mode the unit will operate continuously according to the selected program You will need to add ice peridically for optimal cooling You can select from the following programs Push the Program Q Button to scroll through the available
14. ll free at 1 888 426 3732 from outside the U S call 001 510 868 2100 Opening the case will void the Game Ready warranty To avoid the risk of electrical shock always turn off the System and disconnect the power cord from its electrical outlet when not in use or before adding or emptying ice and water e Do not use any adapter other than that provided by Game Ready Use of other adapters may result in electrical shock and will void the Game Ready warranty PRECAUTIONS Caution This product is for veterinary use only and is not indicated for human use Caution Always attend the animal while the Game Ready Veterinary System is being used in the case that the animal needs to be quickly disconnected from the Control Unit Do not operate the System without any water in the ice box Never operate the System with damaged power cords or Connector Hoses or other mechanical damage or if the unit is otherwise not fully operational Do not pour hot water into the ice box The System was not designed to operate and has not been tested with hot water Do not pick up the Control Unit by the lid Carry using the handle only Do not use other manufacturers wraps with the Game Ready System Do not operate the Control Unit without a Connector Hose attached Be careful not to trip over the System s power cords and Connector Hose or use the product where these are likely to trip an animal The Game Ready Control Unit is a veterinary medica
15. m please contact Game Ready Customer Service from the U S call Toll free at 1 888 426 3732 from outside of the U S call 001 510 868 2100 Warnings e Follow the recommendations of your veterinarian e Improper placement or prolonged use of Game Ready could result in tissue damage such as frostbite e For additional warnings and precautions please refer to pages 5 6 of this manual STEP 9 Press the power button The screen should light up and the Control Unit should beep once The power indicator light should turn from orange to green Adjust the temperature by turning the temperature knob Turning the knob right toward 3 snowflakes will provide more cold therapy Turning the knob left toward 1 snowflake will provide less cold therapy DEVICE CLASSIFICATION Protection against electric shock 5 1 The Game Ready System is considered to be Class protective earth when connected to the Ault Model MW 128 power supply and Class I double insulated when connected to the GlobTek Model GTM 21097 5012 power supply Protection against harmful ingress of water 5 3 This product provides ordinary protection against ingress of water Degree of safety in the presence of flammable anesthetics or oxygen 5 5 Not suitable for use in an oxygen enriched environment or in the presence of flammable anesthetics Electromagnetic interference This equipment has been tested and found to comply with the limits for medical devices in
16. olate the problem Lo a gt e Turn the Control Unit off e f there is air left in the Wrap disconnect the Wrap from the Connector Hose and manually deflate the Wrap e Reconnect the Hose to the Wrap and reapply the Wrap to the body e Turn the Control Unit on and press play pause Deflation Error The Control Unit has detected that the Wrap has not properly deflated gt Co II Pump Performance Error The e Turn the Control Unit off and back Control Unit has determined that on again the fluid pump may be working Check to see if the filter is clogged too hard This could be caused by If that does not solve the problem ice or debris in the fluid circuit urn the Control Unit off for In order to prevent possible 20 minutes to let the pump cool damage to the fluid pump the down before turning it on again to unit will stop therapy ry again Check all hose connections Make sure there is water in the ice box Verify that the ice box filter is not clogged Make sure there are no kinks in the Wrap or Connector Hose Turn the Control Unit off and on again Disconnect and reconnect the hose from the Control Unit and the Wrap Low Flow Control Unit has detected an interruption in the water flow Self Test Error Fluid Circuit e Disconnect the Wrap from the The Control Unit has detected Control Unit an electronic problem in the fluid Turn the Control Unit of
17. post surgical and acute injuries to reduce edema swelling and pain where cold and compression are indicated GENERAL WARNINGS AND PRECAUTIONS Thank you for choosing the Game Ready System To assure you have the best experience possible please be sure to read the entire User s Manual prior to use of the product WARNINGS e Improper placement or prolonged use of Game Ready could result in tissue damage such as frostbite e During the course of Game Ready therapy the treatment provider should monitor the tissue surrounding the treated region or the extremities of the treated limb for any abnormal appearance increased swelling or pain If any of these signs present or any changes in skin appearance occur such as increased redness discoloration or other noticeable skin changes you are advised to discontinue use and consult a veterinarian e The Game Ready Wrap is not sterile do not place directly against open wounds sores rashes infections or stitches May be applied over dressing e The Game Ready wraps are available in multiple configurations but are not intended for all possible uses Use caution when selecting a particular wrap for use on anatomic regions other than that for which the wrap is indicated and closely supervise the animal s status To avoid the risk of electrical shock do not remove any panels from the Control Unit For all servicing and repair please contact Game Ready Customer Service from the U S call to
18. prior to attaching a Wrap AC Adapter to electrical outlet mumm Syste Connect the larger end of the Connector Hose to the Control Unit Make sure you hear it click To disconnect simply press the button and remove the connector from its port Connector Hose to Wrap gt J 13 USING YOUR GAME READY SYSTEM Warning Your Game Ready Control Unit should be plugged into a grounded electrical outlet prior to operation Precautions e Failure to properly follow the set up instructions may result in inadequate therapy e Unplug the Control Unit from the electrical outlet prior to filling the Control Unit with ice and water 4AA Push the door release button to open the ice box door SIAH Close the ice box door Make sure you hear it click Drain Mode This mode allows a user to connect a Hose with a special Hose Adapter o the unit enter Drain Mode and have the unit empty the water out of the ice box through he Hose Drain Mode can be accessed by pressing the program key and toggling through all six programs To empty water in the System while in Drain Mode press the program key until you reach Drain Mode attach the Hose Adapter to the Connector Hose place the Hose Adapter over a sink and press the play button Drain Mode will run the Control Unit s luid pump for up to six minutes long enough to fully empty the ice box Drain Mode is indicated
19. programs Program 1 30 minutes on 30 minutes sleep No pressure Program 2 30 minutes on 30 minutes sleep Low pressure Program 3 30 minutes on 30 minutes sleep Medium pressure Program 4 30 minutes on 60 minutes sleep No pressure Program 5 30 minutes on 60 minutes sleep Low pressure Program 6 30 minutes on 60 minutes sleep Medium pressure Program d Drain Mode Please refer to page 9 in this manual for details STEP 12 Cr Press play pause button To operate the Game Ready System you do not need to remove it from the Bag Simply unzip the Bag s main compartment and end panel Fill the ice box with ice and water Attach the Connector Hose and the AC Adapter to the end panel of the Control Unit and plug the AC Adapter into an electrical outlet 15 USING YOUR GAME READY SYSTEM Syjs2v Apply the selected Wrap consult the Use Guide for each Wrap for application instructions Warning Do not place directly against open wounds sores rashes infections or stitches May be applied over clothing or dressing Caution If applying the same Wrap to another animal make sure the Wrap is deflated before the next application SIJA Connect the smaller end of the Connector Hose to the Wrap Make sure you hear it click To disconnect simply press the button and remove the connector from its port Disconnect Button If you have any problems with the set up of your Game Ready Syste
20. r and the Connector Hose from the Control Unit e Push the door release button to open the door e Carefully dump the ice and water into the sink e Wipe off any excess water e Store the Control Unit in the Carry Bag or in another safe location Store the Control Unit with the lid fully open to allow the interior to dry and preserve the ice box seal e Remember that your Game Ready Control Unit is a valuable piece of equipment and should be treated like a laptop computer with great care Storage Temperature Conditions 1 50 C 33 122 F Relative Humidity 10 95 non condensing Caution Do not keep in extreme hot or cold temperatures above 122 F or below 33 F Do not leave in a hot or freezing car Do not leave the Control Unit in direct sunlight The UV light may damage or discolor the Control Unit SPECIFICATIONS Size 16 25 length x 7 75 width x 9 25 height 413 x 197 x 235 mm not including carrying case Weight 7 3 lb empty approximately 18 Ib full of ice and water Pressure level cycles from 5mm Hg up to 75mm Hg AC power 100 240 V 50 60 Hz 1 0A DC input 12V 2 5A ACCESSORIES The Game Ready Control Unit can be used with any of the following accessories e Any Game Ready Wrap Wraps made by any other manufacturer CANNOT be used with this system e A Game Ready supplied Power Supply Ault Model MW128 or GlobTek Model GTM 21097 5012 and Hospital Grade Power Cord e A Game Ready Connector
21. se complete your Warranty Registration for both the Game Ready Control Unit and the Wraps online at www gamereadyveterinary com The Wrap registration card is packaged with the Heat Exchanger of each Wrap You must register within 30 days from the date of purchase in order to receive warranty service Let us know what you think of our products We d love to hear from you Game Ready CoolSystems Inc 1201 Marina Village Pkwy Suite 200 Alameda CA 94501 In the United States call toll free 1 888 GameReady 1 888 426 3732 Outside of the U S call 001 510 868 2100 www gamereadyveterinary com CLEANING CONTINUED CARRY BAG The Carry Bag should be cleaned using a soft cloth or brush and a mild detergent Febreeze or the equivalent can be used on the Bag if desired If the carry bag has a biological material on the surface Sterifab may be used to decontaminate those surfaces Be sure to test any product on a small portion of the Bag to make sure that it will not damage the Bag MAINTENANCE Inspect and clean or replace the ice box filter as necessary Remove the filter by rotating it counter clockwise No product maintenance should be performed by the user If your Game Ready System requires maintenance please contact Game Ready Customer Service from the U S call toll free at 1 888 426 3732 from outside of the U S call 001 510 868 2100 STORAGE When you are done using the System for the day e Unplug the AC Adapte
22. trol Unit and the Wrap e Prime the Wrap using the following steps Select No Pressure Attach the largest Wrap available Lay the Wrap open not on the body Run the System for 1 minute e Prime the System using the following steps Disconnect the hose from the Control Unit Now look at the Wrap connection location on the Control Unit On the top valve push the white prong in so that it is even with the metal connector Make sure you are not fully covering the opening in the prong Push start and water should squirt out of he valve Restart the System Over Pressure Indicates that the Control Unit has exceeded the target pressure e Turn the Control Unit off and back on e Apply the same Wrap more tightly e Apply a different Wrap THE GAME READY DIFFERENCE THE GAME READY DIFFERENCE Game Ready was built upon the concept that the principles behind spacesuit technology could be used to develop an injury treatment system As a designer for the National Aeronautics and Space Administration NASA and an inductee into the U S Space Foundation s Hall of Fame our founder helped pioneer the technology involved in controlling pressure and temperature within a flexible garment In 1998 we began working with athletes athletic trainers doctors and veterinarians to expand breakthrough discoveries into the realm of sports medicine for both people and animals REGISTER YOUR PRODUCT Plea
23. www gamereadyveterinary com click on the Product Registration link at the top of the page fill out and submit your information Extended Warranties Extended Warranties are available for the Game Ready System For details and information please contact Game Ready Customer Service from the U S call toll free at 1 888 426 3732 from outside of the U S call 001 510 868 2100 Game Ready Control Unit User s Manual PN 703171 Rev A C 21 20 WARRANTY CoolSystems warrants that the Game Ready Control Unit if properly used will be free from defects in material and workmanship for a period of one 1 year after the date the Game Ready Control Unit was purchased If the Game Ready Control Unit which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty CoolSystems at its options will e REPAIR the Game Ready Control Unit OR e REPLACE the Game Ready Control Unit with another Game Ready Control Unit THIS LIMITED WARRANTY AND ANY IMPLIED WARRANTIES THAT MAY EXIST UNDER STATE LAW APPLY ONLY TO THE ORIGINAL PURCHASER OF THE GAME READY CONTROL UNIT AND ARE NON TRANSFERABLE Extent of Limited Warranty This limited warranty does not cover damages due to external causes including without limitation accident usage not in accordance with product instructions misuse neglect alteration or repair How to Obtain Warranty Service To obtain warranty service please contact
Download Pdf Manuals
Related Search
Related Contents
MODE D`EMPLOI WEB-DECLARATIONS ベルトレンチセット BMW 740i Sedan Service and Warranty Information general music manuel des workstations ws2 et ws400. Quelques idées simples sur les politiques foncières Whirlpool MH1160XSB1 User's Manual nível - Warme 5 - Hangar-9 取扱説明書 - TOTO Genie I/II - 8Bit Copyright © All rights reserved.