Mini circuit breaker and RCD

image

Contents

1. SHANGHAI XINCHI ELECTRIC CO LTD Add No 65 Haifeng Road Baoshan District Shanghai China Tel 0086 21 51619313 Fax 0086 21 61294397 EQING XINCHI ELECTRIC8 SSCIENCE TECHNOLOGY C m 1 Wanjia Industrial Zone Malujiao North Baixiang Wenzhou Zhejiang China Tel 0086 577 62890205 Fax 0086 577 62890578 E mail julie chinasuntre e cCOM www china suntree com These are only a part of our products in this guide catalogue if you need more information please contact us Because of rapid product technology innovation the products in tl guide should be based on practical products or user manual if any changements please forgive us not to inform separately mentally friendly paper ior e a 9 ra U LLI E 9 E n I gi iiih i Lal eo r 1 I I M ILI I c 1 r1 FERRI mm ID rm sitial T g or we E I kE AS Se oe La A 417 LE d E 5 gt IN LINIMIEZSEIMSEMIEIE TY khi f Company Profile ShangHai XinChi Electric Co Ltd is a group company There are four branch companies subordinate to it Yueqing XinChi Electric amp Science Technology Co LTD YueQing IMP and EXP Co Ltd HK Yangming Electrical Technology Co Ltd Wenzhou Litto smart Co Ltd Registered trademark is suntree ShangHai XinChi Electric Co Ltd is
2. 51 www china suntree com SDXL RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 80A 2 4Pole A amp AC curve Similar siemens Electronic and electromagnetic S5SM1 RCD Application S5SM1 series earth leakAge breakers apply to AC circuit of 50Hz rated e9 208 voltage up to 415V rated current up to 80A It is mainly used as an 9 9 d j Pod indirect protection for human It also can be used to prevent against the p fire danger caused by earth fault current owing to equipment insulation ms ae UP damage When the protective measures of the electric shock are out of x work the RCCB whose rated residual operating current less than 30mA LR can serve as the supplementary protection for indirect contact but it can 920 e 909 9 not be used as the sole direct contact protection Product features e S5SM1 series earth leakAge breaker are the protector pure electromagnetic residula current operation e The operation function is unrelated to circuit voltage but operation is reliable e t can be reliably operated on the loss of phase or neutral e The capacity of resisting electromagnetic interference is strong Specifications Im Inc lAn A no The Max of break times Type Un V Hz IAA IA m IA m mA mA 1AN 2AN 5 A N 0 25A 500A 6 10 16 30 15 0 2 0 1 0 04 0 04 500A 32 40 50 25 0 2 0 1 0 04 0 04 S5SM1 In 50A 75 40 0 2 0 1 0 04 0 04 2 30 6000A 50 63 2P 10In am 100 50 0 2 0 1 0 04 0 04 In 50A 300 150 0 2
3. 5j 5 C 40 C IP20 Not less than 8000 times Not less than 20000 times e Complete accessories 4P 70 10000 SENE 52 5 5000 2P 35 2000 e in V LLLA ELLE LT 0 005 E B type C type D type Oe zines 2 345 7 10 2030 5070100 200 V IK Current limiting short circuit energy times Short circuit Prospective short circuit current peak value Prospective Short cXcuit energy 10ms 0 www china suntree com SL7 63 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 1 N 2 3 3 N 4 Pole IEC60947 2 SAA CE TUV CB Nemko Triangle indicator window SL 63N MCB Application SL7 63N have protective function as shortage as overload and s s are used in lighting distribution system in industry commerce and dwelling and protect fractional electric motors And they also have oo many merits of high protective grade up to IP20 high breaking capacity reliable sensitive action convenient multi pole assembling long life ect They are mainly adapted to the circuit of AC 50Hz 250V in single pole 415V in double three four poles for protecting overload and short circuit Mean while they are also used in turning on or off the electric apparatus and lighting circuit under the normal conditions Specifications Standard EN60898 IEC60898 IEC60947 2 Rated current 1 63A 6 10kA IEC60898 0 5 63A Rated Breaking capacit sen 6 10 15kA IEC609
4. Keyword 6 63A 1 2 3 4 Pole Similar AEG High breaking capacity Orange handle SE90 MCB Application The mini circuit breaker belong to the advanced level of the nineties in the world They are characteristic of small size high sensitivity long using life and strong protective functions for shortage and overload The products are the newest generation and has features of high protective grade high breaking capacity good reliability of sensitive action and convenient use It is generally used for illumination and distribution in industry commerce and buildings Specifications Rated current 6 10 16 20 25 32 40 50 63A Rated voltage AC Un 230 415V Min operating voltage UB min 12 Tripping characteristics 3 5In B 5 10In C 10 20In D Mechanical electrical educate 2000 10000 Triplications acc to IEC 60898 95 RH at 55 Terminal capacity flexible rigid able 25 35mm Poles 1 2 3 4 Weight g pole 120 Characteristic curve Ip s nominal current when operating voltage is 230 400V lp s nominal current when operating voltage is 230 400V d 7 E i B63 S amp B40 5 B32 5 B25 B16 g B10 4 B6 3 e 2 1 9 0 0 5 1 5 3 4 5 6 7 5 10 0 5 1 5 3 4 5 6 7 5 10 B Estimated short circuit current Icc KA gt C Estimated short circuit current Icc kA www china suntree com 18 SE90 MCB SHANGHAI XINCHI ELECTRI
5. Operating principle E ul ul ul NI T E L1 N LI L2 L3 N www china suntree com 50 SCD SAD RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 16 25 40 63A 2 4Pole A amp AC curve Consumer Unit Mount Distribtuion Board Mount SDXL RCD Application SDXL series Residual current breaker without over current protection is suitable for the line of AC 50 60Hz voltage 240V 2pole 415V 4pole rated current up to 63A When there is human electricity shock or if the leakage current of the line exceeds the prescribed value it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage It can be used as infrequent changeover of the line in normal situation It is applicable to industrial area commercial area tall building and civil house It complies with standard IEC61009 1 Specifications Frame class 63A Rated working voltage 240 415V Rated frequency 50 60Hz Rated working current 16 25 40 63A Rated rdsidual operating current 0 03 0 1 0 3 0 5A Rated residual un operating current 0 015 0 05 0 15 0 25A Sensibility A amp AC Type Maximum operating time A nt x 0 15 5l A nt lt 0 04s Rated making and breaking capacity In lt 50A 500A In lt 63A 630A Limiting value of un operating current 6In Rated limiting short circuit current 6000A Pole number 2P4P Mechanical life 20000 Electric life 4000 Dimensions Operating principle
6. Current Current Limits Current Current Limits IS IEC60898 1 E UCET NA T E l t l l t eS ele 21h BOC gt 0 1s OR B Curve EAS Xn lt 1h 5o lt 0 1s _ 100 00 1 13 xl gt 1h 5xl gt 0 1s ae C Curve TASKI lt 1h 10x lt 0 1s Sx gt 1h TOL gt 0 1s D Curve a 145xl lt 1h 20xl lt 0 1s 1s t 60s for In 32A 1 13 1 45 Multiples of Rated Cumt xh 2 55 1s lt t lt 120s for In gt 32 A 23 www china suntree com SHL MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3Pole Similar LS also have BKP BKN B C BKH BFN BKM LSN SBKN MCB Application The design on the base of the current limiting device increases the ca pability of circuit breaking with a max of 7 5kA AC 230V standard e e e e The super miniature and light product leaves the installation are minimum The over current protection of bimetallic sheet and the instan 5 23 i taneous and short circuit protection featuring solenoid trip pro he 4 mi x duces a perfect protection to current fault au RES The assembly mode of DIN Rail makes the installation easier Delicate appearance of Europe style e e e e e Available to fit such accessories as auxiliary switch AX and alarm switch etc Specifications Series SBKN Type B C D Poles 1 2 3 1 2 3 4 1 2 3 Rated voltage 230 415V Rated current 1 3 6 10 16 20 25 32 40 50 63 Breaking capacity kA 6 6 6 Tripping device Thermal coil magnetic Auxili
7. Rated operation power NO 230V Single phase 4 0kW 5 3kW 8 8kW 13 8kW 230V Three phase 9kW 15 2kW 24kW 400V Three phase 16kW 26kW 41kW AC 3 AC 7B switching motors Rated operation current le NO 9A 9A 22A 30A Rated operation current le NC Rated operation power NO 9A 6A 230V Single phase 1 3kW 1 3kW 3 7kW 5kW 230V Two phase 2 2kW 5 5kW 8kW 4kW 11kW 15kW 400V Four phase Dimensions 45 5 0 13 81max 85max 35 0 24 SUE i 18max 45max Weight lt 125g Environmental temperature 5 C 40 C Mechanical lifetime not less than 1x10 times Electric lifetime not less than 3x10 times www china suntree com 68 HC1 series Modular Contactor SHANGHAI XINCHI ELECTRIC CO LTD Other product for MCB Hager Series e r a Hager Series TSM Series www china suntree com Other product for MCB
8. 0 1 0 04 0 04 0 04 500 250 0 2 0 1 0 04 0 04 0 04 50 60 30 15 0 2 0 1 0 04 0 04 500A 6 10 16 50 25 0 2 0 1 0 04 0 04 S5SM1 In 50A 32 40 75 40 0 2 0 1 0 04 0 04 415 6000A 4P 10In 50 63 100 50 0 2 0 1 0 04 0 04 In 50A 80 300 150 0 2 0 1 0 04 0 04 0 04 250 0 04 0 04 0 04 Dimensions 90 4 A A 12 6672 www china suntree com 52 S5SM1 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 4 40A 1 N 2 4Pole A amp AC curve Distribtuion Board Mount Similar AEG SE9 RCD Application L 3 E 3 3 SE9 is our newly developed electronic leakage circuit breakers e 9 9 combine overload short circuit leakage over voltage protection a WE W function whole in one product it also can be mounted the under mus LU voltage release shunt release auxiliary contactor and other 2 A accessories in side mainly is suitable for the commercial building B o and civil construction VUE e 10 0o 9 9 Specifications SE9 HD90 D90 HD92 D92 Standard IEC61009 Tripping characteristics C Current limit class 3 B No Of Poles 1P N 1P N 2P 4P Calibration Temperature C 30 30 30 Operating Temperature C 25 55 25 55 25 55 Storage Temperature C 25 55 25 55 25 55 Rated current A 6 40 4 40 4 40 1P 1P N 230 240 230 240 230 240 AC V 2P 230 240 Rated Voltage V 3P 3P N 4P 400 1P DC V 2P series Voltage Pollution Degree 3 440 440 440
9. 1 and BS4293 It can cut off the fault circuit immediately on the occasion of shock haz ard or earth leakAge of trunk line It is suitable to avoid the shock hazard and fire caused by earth leakAge SFIN RCD is mainly suitable for use in varieties of plants and enterprises Building construction commerce guest houses and families it can be used in circuits up to single phase 240V three phases 415V 50 60Hz Specifications Type SFIN25 SFINAO SFIN63 Rated Current L n A 25 40 63 Rated Operating Current For Earth LeakAge L n A 0 03 0 1 0 3 0 5 Rated Non operating Current For Earth LeakAge L n A 0 51 n A Voltage V 240 220 415 380 Pole No 2 4 Operating Time second A n A 21 n A 0 25A or51 A n Limited Value of Non operating Current For Balance Load or 0 2 0 1 0 04 Unbalance Load 2 A n A In Min Value of Rated Operating and Breaking Capacity Rated Conditional Short Circuit Inc A 1500 2000 3000 Endurance times 4000 Dimensions www china suntree com SFIN RCD 48 SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4Pole A amp AC curve Electronic and electromagnetic Color indicates SNFIN RCD Application The residual current device RCD NCIN is in conformity with the standards of IEC61009 1 and BS 4293 It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakAge of trunk line Thus it is suitable
10. 2P 3P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical life 6000 Mechanical life 20000 Specifications e Number of Poles 1P 2P 3P 4P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical life 6000 e Mechanical life 20000 33 www china suntree com S MCB Series miniature circuit breaker SHANGHAI XINCHI ELECTRIC CO LTD S MCB Series miniature circuit breaker SBH Specifications e Number of Poles 1P 2P 3P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical life 6000 e Mechanical life 16000 e Dimensions 42 x 28 x 43 5 e Gross weight 22kg Net weitht 21kg SBH P Specifications e Number of Poles 1P 2P 3P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical life 6000 e Mechanical life 16000 e Dimensions 34 x 28 x 44 e Gross weight 22kg Net weitht 21kg SNEN Specifications e Number of Poles 1P 2P 3P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical lif
11. C Im A 115V 1500 230V 1000V Protection degree IP20 Protection degree IP20 Dimensions Ti www china suntree com 62 SNT50 SNT50L MCB RCD Plug in out style surge protective device Remote signaling interface could be remote control Suitable for the wind power generation and PV system UP 2 kV SAFE PRO i aa SAFE PRO In KA n Ra Ue 420V Uc EUR n r imax 40K 4 ax 40KA 0 ZOKA In Up 3 Imax 40K 2 0K p lt 7 0RV f SB8021 2002 GB18802 1 2007 SHANGHAI XINCHI ELECTRIC CO LTD Comply with IEC61643 1 IEC61643 21 and UL1449 ed 2 Standards Lightning induced surges and electrostatic discharges can create very strong electromagnetic radiation over long distances which can destroy all equipments connected to any nerby power lines Whether routed inside or outside the buildings all lines are at risk from such discharges and therefore the use of Surge Protection Device SPD is highly recommended for protecting the equipments that are connected to the power lines Also surge can be induced by impulse current generated from internal supplying system and the ON and OFF start and stop of the power equipments such as arc furnace motor electrical and mechanical switching capacitive and inductive load etc These surge currents would destroy any precise electronic device cause error message or failure of power equipments shorten their life expectancy and ev
12. C BSurge protective device SHANGHAI XINCHI ELECTRIC CO LTD Keyword with Fuse Imax 120kA 1P 2P 3P 3P NPE 4P Similar DEHN guard SUP2 Surge protective device Application La la i e e e e SUP2 series surge protective device hereinafter called SPD is suitably used in the TT TN S TN C IT TN C S and etc power supply system of AC 50 60Hz rated voltage 380V and below to protect from direct and indirect lightning impulse and other transient over voltage SPD meets with GB18802 1 IEC61643 1 standard Installation Remote signaling interface SUP2 is mounted between LPZ1 or LPZ2 zone and LPZ3 zone The cross sectional area of multi strand soft copper conductor to be connected 2 5 35 mm It is used in distribution boxes of living house computer center communication equipment electronic equipment and control equipment or nearestsocket box NS6 40 is mounted between LPZOB or LPZ1 zone and LPZ2 zone The cross sectional area of multi strand soft copper conductor to be connected 2 5 35 mm Specifications Type amp Specs SUP2 15 SUP2 40 SUP2 65 SUP2 80 SUP2 100 SUP2 120 Max Continuous operating voltage Uc VAC 4200275 14201275 E712 ON 2753542055275 420 DET EAR 4275 Protection voltage level UP kV lt 2 2 IEOOIITES S eS 122 50 051552 52 53 eS 12559 12 051 3 2 120 Max discharging current 8 20 u s Imax kA 15 45 65 80 100 120 Max discharging current 8 20 u s lmax kA 5 15 30 40 50 60 Respon
13. failure release mounted on the EI m module of surge protection device When the SPD fails in breakdown zm LE LE M for over heat and over current the failure release will help electric equipments separate from the power supply system and give the indication signal green means normal red means abnormal it also could be replaced for the module when has operating voltage Product features e Could be replaced for the module not need power off Maximum current of endure the lightning stroke 40kA 8 20 y s e Time of response 25ns The color of visible window shows operating status green means normal red means abnormal Specifications Technical Parameters SUP1 D C B Protection Level B C D Grade D C B Rated Operating Voltage Un V 380V 220V Maximum Continuous Operating Voltage Uc V 275V 320V 385V 385V 385V 420V Voltage Protection Level Up V kV lt 1 0 lt 1 2 lt 1 8 lt 2 0 lt 2 2 lt 2 8 Nominal Discharge Current In 8 20s kA 5 10 20 30 40 60 Maximum Discharge Current Imax 8 20s kA 10 20 40 60 80 100 Response Time ns lt 25 Test Standard IEC61643 1 GB18802 1 Operating Environment centigrade 40 C 85 C Max Connection Line 35mm2 hard wire 35mm2 strand wire copper line Recommended Connection Line 16mm2 hard wire 25mm2 strand wire copper line Installation Standard Rail 35mm Material of Outer Covering Burning proof Nylon Dimensions www china suntree com 64 SUP1 D
14. for terminal distribution protection overload and short circuit protection can also be used to infrequent making and breaking operations This breaker complier with standards of EN60989 1 and GB10963 1 2005 etc Specifications Rated voltage Rated frequency Rated current Number of poles Tripping characteristic Rated ultimate short circuit breaking capacity Icu Rated service short circuit breaking capacity lcs Mechanical life Dimensions AC 230V 50Hz 60Hz 1 2 3 4 6 10 16 25 32 40 50 63A 1P N B C D 6000A 6000A 20000 times 2 www china suntree com SDPNa MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1P N 18mm Consumer Unit Mount Distribtuion Board Mount SDXN MCB Application SDXN mini circuit breaker applies to locations such as industrial commercial high rise and civil residence with AC230V and below for terminal distribution protection overload and short circuit protection can also be used to infrequent making and breaking operations This breaker complier with standards of EN60989 1 and GB10963 1 2005 etc Specifications 4 Rated voltage Rated frequency Rated current Number of poles Tripping characteristic Rated ultimate short circuit breaking capacity lcu Rated service short circuit breaking capacity lcs Mechanical life Dimensions AC 230V 50Hz 60Hz 1 2 3 4 6 10 16 25 32 40 50 63A 1P N B C D 6000A 6000A 20000 times 70 5 M
15. to avoid the shock hazard and fire caused by earth leakage SNFIN RCD is mainly suitable for using in varieties of plants enterprises building Constructions commerce hotels and families It can be used in circuit up to single phase 230V three phase 415V 50 60Hz Specifications Rated Voltage Un 2Pole 230V AC 4Pole 415V AC Rated Current In 25 40 634 Rated Residual Operating Current l A n 30 100 300 500mA Rated Residual Non operating Current l A no 0 51 An Rated Current off time lt 0 1s Min Value of Rated Operating and Breaking Capacity Im 1kA Rated Conditional Short circuit Current Inc In 25 40A Inc 1500A In 63A Inc 3000A Installation On symmetrical DIN rail Endurance times 4000 Operating principle www china suntree com SNFIN RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4Pole A amp AC curve Distribtuion Board Mount Similar Hager SCD SAD RCD Specifications Standard IEC61009 1 Rated Voltage Un 2Pole 230VAC 4Pole 415VAC 919 e e Rated Current In 25 40 63A Rated Residual Operating 30 100 300 500mA Current I A n 0 51 An gt _ gt d ar Rated Current off time lt 0 1s po wn 3 Minimum Value of Rated Operating A Ix Mw and Breaking Capacity Im Rated Conditional Short circuit In 25 40A Inc 1500A In 63A r e o o 9 Current Inc Inc 3000A cms Installation On symmetrical DIN rail dnd di Dimensions 35 0 0 3 86 0 8 45
16. used for an unfrequented switch over of the circuit and illumination under normal conditions Specifications Transparent shell Type SMY SMT Rated current 6 40A 6 63A Tripping curve B 3 5In B C D B C D C 5 10In D 10 20In Breaki it a rai 5k Asta IEC 947 2 ie oe 10kA C 22kA C NEMA AB 1 se seu Rated voltage Isolating voltage Electrical life Dimensions Characteristic curve IEC60898 SMU 2 63A 6kA 10kA 22kA C 230 400V 500V 0 5 to 32A 20000 times 40 to 63A 10000 times SMW 1 63A 6kA 10kA 22kA C B curve 10000 6000 4000 3600 2000 10000 0 6 0 04 0 02 0 01 0 004 l C curve 10000 6000 1000 600 400 40 20 0 04 0 02 D curve www china suntree com 26 SMY SMT SMU SMW MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 2 32A Custom made for 32A color white and Black Plug in installation S101 MCB Application The circuit breaker are suitable for AC and DC 32A electric circuits of 50Hz up to 380V and up to DC 250V respectively for protection of electrical circuits and apparatus in office and residence bu
17. 000Times Dimensions It can be mounted with railway and can busbar Operating principle www china suntree com 46 SF360 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4 Pole Consumer Unit Mount Distribtuion Board Mount SFI 100 RCD Application SF1 100 Residual current circuit breaker provide the functions of isolation switching and earth leakAge protection of electrical circuits And also provides the indirect protection of the operator s body against the dangerous effects of electric current and provides the protection of the fire caused by the electrical circuit fault Specifications Type SF1 100 Standard IEC61009 1 No of Poles 2P4P Rated Current In 25 40 63A Rated Residual Operating Current l A n 30 100 300 500mA Rated Residual Non operating Current l A no 0 51 A no Rated Voltage Un AC 230 240 400 415 V Residual Current off time lt 0 1s Short circuit Capacity Inc In 25 40A Inc1500A In 63A Inc3000A ae On load 2000cycles Off load 2000cycles Protection Degree IP20 Dimensions Operating principle ez ie INI 4 www china suntree com SFI 100 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4 Pole Consumer Unit Mount Electronic and electromagnetic SFIN RCD Application The earth leakAge circuit breaker SFIN is in conformity with the stan dards of IEC61009
18. 00cycles On symmetrical DIN rail Operating principle 45 www china suntree com SIDN RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 16 63A Shell is made of plastic and Electric Jado powder Electronic and electromagnetic Different appearance SF360 RCD Application The item is in accordance with standards of IEC61009 1 and BS4293 9 9 9 eo 9o 9 etc Applying to the circuit of AC 50 60Hz 230V single phase 415V W three phases and below it for industrial and mining enterprise building un ZE trade commerce and family To mainly prevent electric fire and personal d LL casualty accident caused by personal electric shock or leakAge of a THALES as electrified wire netting this RCD is a current operated fast leakAge 91 rotector of pure electromagnetic type Which can break off fault circuit r US E gt d i a alea ai d ti 9 2 o 0 0 rapidly in order to avoid occurrence of accident a Plastic shell Electric Jado Powder shell Specifications Type Rated Current A LeakAge Acting Current Range of Break off Rated Voltage SF362 16A 25A 32A 40A 63A 10mA 30mA 100mA 300mA 0 5 1 0XI An 230V 220V SF364 25A 32A 40A 63A 30mA 100mA 300mA 0 5 1 0XI A n 230V 415V 220V 380V Technical data Tripping Time 100ms depending on specifications 5XI n400ms Ambient Temperature 5 C 55 C Climatic Resistance 55 C 28 C cycles Vibration Resistance Min 5g 30mm 0 8Hz Life Expectance More Than 10
19. 03 500 10000 0 1 50 60 4000 2 500 7 2000 2000 Yes IP20 5 40 Special application please refer to pe55 for temperature compensation correction 25 70 Cable U type busbar pin type busbar 16 18 5 10 18 8 2 18 On DIN rail EN 60715 35mm by means of fast clip device From bottom www china suntree com 58 SNLE RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 10 60A 2 4Pole African models circuit breaker and ELCB SCGD ELCB Application SCGD earth leakAge circuit breaker its rated current is adjustable from 10A up to 60A User can select suitable current for better pro tection against overload and short circuit Specifications Type SCGD230 SCGD430 Poles 2P 4P Rated Voltage V 250V A40V Rated Current A 10 15 20 30 45 50 60A adjustable LeakAge Motion Current mA 500mA LeakAge Dead Current mA 250mA Standard NFC61450 SCGD Series leakAge overload breaker Application SCGD earth leakAge circuit breaker is suitable in AC 50Hz 250 440V cir i l cuit with overload and overload and earth leakAge protection The rated current is adjustable from 10A up to 60A User can select suit able current for better protection against overload and short circuit Specifications Type SCGD230 SCGD430 Poles 2P 4P Rated Voltage V 250V 440V Rated Current A 10 15 20 30 45 50 60A adjustable LeakAge Motion Current mA 300mA 500mA 300mA 500mA LeakAge Dead Current mA 150mA 250mA 150mA 2
20. 0sT4s16 1 13932 1832 2 2 4 Nominal Discharge Current In 8 u 20 u s kA 5 10 15 20 30 40 Maximum Discharge Current Imax 8 u 20 u s kA 10 20 30 40 60 80 Response Time ns lt 25 Test Standard GB18802 IEC61643 1 The Cross Section of L N Line 6 10 16 The Cross Section of PE Line 10 16 25 Fuse or Switch A 10 16 532 40 Operating Environment C 40 C 85 C Relative Humidity 25 C lt 95 Installation Material Of Outer Covering Dimensions Standard Rail 35mm Fiber glass reinforced plastic SUP4 SUP4 SUPA SUP4 67 www china suntree com SUP4 Surge protective device SHANGHAI XINCHI ELECTRIC CO LTD Keyword Max current 63A Standard rail 35mm Household AC Contactor HC1 series Modular Contactor Application ee aa HC1 series modular contactor is mainly sed for the electric power e e 1 system with AC 50Hz or 60Hz and rated working voltage up to a 400V Under the using category of AC 7a the product can serve for mis HC1 25 EI remote switch and master circuit control in the circuit with rated E working voltage up to V and rated working current up to 63A e 254 This product can be used for loading control of household electrical RE appliance and low induction loading and household motor with e similar usages ww Specifications AC 1 AC 7A swithing of heaters HC120 E175 HC140 IC 163 Rated operation current le NO 20A 25A 40A 63A Rated operation current le NC 20A 25A 30A 30A
21. 45In Hot state 1h Trip 40 50 60 5In Cold state gt 0 1s Non trip 10In Cold state 0 1s Trip Attentions a When use it should choose the right one if not the products cannt protect the circuit b TEST button should testing four times one month checking the earth leakage function c When use it should choose the right current if not the product dont have over current and short circuit protection functions 61 www china suntree com SM3L63 ELCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 32A 1 NPole Consumer Unit Mount Distribtuion Board Mount SNT50 SNT50L MCB RCD Application SNT50 series safety type mini circuit breakers features lively machine excellent quality beautiful appearance small volume The product is suitable for AC 50Hz rated voltage up to 240V rated current up to 32A it is used for protection of the overload and short circuit of all kinds of modern family applicable apparatus It can also be used for unfrequented operation and control SNT50 MCB SNT5OL Residual current circuit breaker Standard IEC60898 Number of pole 1P N 2P Number of pole 1P N 2P Rated current In 61015 20 25 32 Rated current In 5 1015 20 2552 Rated voltage Un 115 230V Rated voltage Un 115 230V A n mA 10 15 30 Rated frequency B C A n mA 57515 Tripping curve gt 6000 times Tripping curve gt 6000 times Electrical life 10000 times Electrical life 10000 times Tropical ration Treatmen 2 RH95 at 55
22. 47 2 0 5 63A Characteristic curve BED Max fuse that can be connected to 100AgL 10kA Selective grade 3 Working ambient temperature 5 C 40 C Enclosed protective class IP20 Electrical life Not less than 8000 times Mechanical life Not less than 20000 times e Complete accessories Dimensions Characteristics curves 4P 70 gt zi 10000 3P pem 5000 Short circuit Prospective short circuit 2P 35 2000 current peak value Prospective Short cXcuit energy B type C type D type 80 o N Current limiting peak value Current limiting l short circuit energy times 0 WS 10ms ev ev ev ev 0 5 2 3457 10 2030 5070100 200 V IK www china suntree com 04 SL7 63N MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 1 N 2 3 3 N 4 Pole Improved SL7 63 Indicator panel can be removed with handle sets SL7 63 MCB 05 www china suntree com SL7 63 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword Max current 125A 1 1 N 2 3 3 N 4 Pole Breaking Capacity 7 5kA Similar Admiralty Muller SL7 125 MCB Application D This circuit breaker is applied to protect the over current of electrical YT apparatus and circuit device of construction and similar buildings in Daam WAL the circuit of AC 50Hz rated voltage 230V 400V and rated current J up to 125A It can also applied for unfrequent making breaking c operation It accords with IEC60898
23. 50mA 59 www china suntree com SCGD ELCB Widespred use for southeast Asia market Earth leakage current is adjustable patent product SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4Pole Leakage current is adjustable With LED indicator Commonly used products of the southeast Asian market SM3L 63 Adjust Family Type Moulded Case And Earth Leakage Circuit Breaker Application SM3L 63 Series RCCB is suitable for the circuit of AC 50 60Hz rated working voltage 230V and rated current 60A and below to make indirect contact protection to the human being and protect the circuit against over current short circuit and surge protector in buildings or other similar locations as well Best selling circuit breaker in Southeast Asia Model and implication S M 3 L 60 G af SUNTREE MCCB Designing Leakage Current Over Remote Brand number function grade voltage control Protection function E TE Specifications a Over voltage protection technical data Choose shift position Ino mA In mA Remark SMA 4 8 10mA 8 12 Power on close circuit breaker press TEST circuit breaker working when the TEE 12 T power supply normal then press function button the LED on when press DIRECT 2 the red light on the products dont working 30mA 18 30 b Over voltage protection technical data Testing current Rated current Start state Testing time Testing result 1 13Iin Hot state gt 1h Non trip 20 25 32 1
24. AX On cce www china suntree com 30 SDXN MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 32A 1P N 18mm Consumer Unit Mount Distribtuion Board Mount SDZ30 MCB Application SDZ30 mini circuit breaker is mainly suitable for overload and RENI DEN short circuit protection It is especially used for illumination and e ee distribution in industry and capacity etc It has pleasing outlook Fem ae amp high breaking capacity reliable performance high inflammable e ce eu ce oim ELI a P umo xm a xm resistance and shock resistance for long service life It is within the circuit of AC 50 60Hz rated voltage of single pole up to 240V two three or four poles up to 415V It can also be used for an unfrequented change over or the circuit and illumination under j amp normal conditions Specifications Rated current Pole Rated voltage Breaking capacity Electrical life Mechanical life 1 2 3 4 6 1pP N 240V 6000 8000 times 10000 times 10 16 20 25 32A Dimensions Characteristic curve 10000 5000 2000 1000 500 200 100 0 005 0 002 0 001 05 1 2 3457 10 2030 5070 00 200 I In 31 www china suntree com SDZ30 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 32 63 80 100A 1 2 3 4 Pole Consumer Unit Mount Distribtuion Board Mount SHL30 Switch disconnectors Main specification and technical parameter N
25. C CO LTD Keyword 1 63A 1 2 3 4 Pole Consumer Unit Mount Similar Legrand Other improved products SDX MCB Application SDX mini circuit breaker is mainly suitable for overload and short circuit protection It is especially used for illumination and distribution in industry and commerce etc It has pleasing outlook amp high breaking capacity reliable performance high inflammable resistance and shock resistance for long service life It is within the circuit of AC 50 60Hz rated voltage of single pole up to 230V two three or four poles up to 415V It can also be used for an unfrequented change over of the circuit and illumination under normal conditions Specifications Rated current A Pole NO 1 1 2 3 4 6 10 16 20 25 32 40 Dod 1 50 63 234 Dimensions 30 25 Characteristic curve Rated voltage V 230 415 220 415 Breaking capacity kA 6000 6000 6000 6000 Electrical life times 8000 Mechanical life times 6000 10000 5000 2000 1000 500 200 100 50 20 10 0 5 0 2 0 05 0 02 0 01 0 005 0 002 0 001 0 5 B 3 5 In C 5 10 In D 10 14In 2 34 57 10 20 305070100 200 I IR 19 www china suntree com SDX MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 2 63A 1 2 3 4 Pole Similar Siemens other models can be customized S5SJ6 S5SL6 MCB Application S5SJ6 series mini circuit breaker is mainly suitable for over load an
26. GB10963 standard Ei Specifications Frame size rated current Inm 125A Rated voltage Ue 50Hz 230V 400V Rated current In C type 63A 80A 100A 125A D type 63A 80A 100A Rated breaking capacity Ics 7500A Icn 15000A Pole number 1P1P N 2P3P3P N 4P Mechanical life 8000 times Electric life 4000 times C Type use in lighting distribution socket loop or parts of motivity distribution system Instantaneous release type and current range D We D Type use in motivity or strong electromagnetic induction load loop for example motor load etc 10In 20In Dimensions Characteristics curves mim ES eo 0 1 108max www china suntree com 06 SL7 125 MCB SHANGHAI XINCHI ELECTRIC CO LTD Application examples Stop Stari Load 07 www china suntree com Application examples SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Consumer Unit Mount Distribtuion Board Mount Economic utility SC45 MCB Application men mI 55 e 9 9 SC45 series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short circuit z cm Tj in the system The product is novel in structure light in weight Ea m ze IP 4 reliable and excellent in performance It has high breaking capacity a B ha can trip quickly an
27. Large current carrying capacity fast response time low residual voltage Specifications Type amp Specs SUP3 15 SUP3 40 SUP3 60 SUP3 80 SUP3 100 SUP3 120 Max Continuous operating voltage Uc VAC AZO 275 420 275 420 275 420 275 420 275 420 275 Protection voltage level UP kV lt TONTON ETE ele id 2 59 EN 2550 TES e2 Sne 0 330 ESQ Max discharging current 8 20 p s Imax kA 15 45 60 80 100 120 Nominal discharging current 8 20 u s In kA 5 15 30 40 50 60 Response time ns 25 Invalidation indicating Aging invalidation white Normal red invalidated Protection degree IP20 Application Protection for incoming line Dimensions 69 95 www china suntree com 66 SUP3 Surge protective device SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1P 2P 3P 4P NPE Similer Schneider Imax 80A SUPA Surge protective device Application SUP4 series Switch type high energy surge protective Apply for power supply system below 380VAC e Could be replaced for the module not need rower cut e Maximum current of endure the lightning stroke 65kA 8 20 p s e Time of response lt 25ns e The color of visible window shows operating status green means normal red means abnormal Specifications Rate Operating Voltage Uc V 220V 380V Maximum Continuous Operating Voltage Uc V 275V 440V 275 320 385V 440V 375 385V 440V Voltage Protection Level Up V kA lt 0 8 spo dsTm
28. MX OF MQ Switch disconnectors MV MN SH3 100 SH1 100 SB463 SBH 100 www china suntree com Miniature circuit breaker accessories SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 63A 1 2 3 4 Pole Breaking Capacity 6kA Similar Mitsubishi SBH D6 MCB Application SBH D6 products of domestic power distribution box have come out The high quality and high function circuit breaker used in domestic e ia used in domestic power distribution box is looking for ward to your selection and application TE Function h i i e All the machines meet the standards of IEC and GB e j e e They can be installed in the track of 35mm of IEC e They have the function of high current limit 9 Protective grade IP20 Specifications Standard IEC60898 Rated voltage 230 415VAC 50 60Hz Rated current 6 11 13 16 20 25 32 40150 63 Ambient temperature 10 C 40 C Instal trip current B C D Rated short circuit interrupting capacity 6kA Rated running short circuit interrupting capacity 10kA Mechanical life 8000 Electrical life 8000 Fix Track of 35mm of IEC Terminal the side of ON Non weld tin terminal Terminal the side of OFF Non weld tin terminal terminal with mouth Bus t 0 7 1 5mm Applied wire 1 25mm Releasing method of overload Thermal coil magnetic Accessories Insulation board Dimensions 17 www china suntree com SBH D6 MCB SHANGHAI XINCHI ELECTRIC CO LTD
29. N 2 3 3P N 4P isolator type India market selling products SIS 63 MCB Construction and Features State of the art design Elegant appearance cover and handle in arc shape for comfortable operation Contact position indicating window Ms l Mid trip function for circuit fault indicating In case of overload and short circuit to protected circuit mcb knob trips and stays at mid position which enables a quick solution to the faulty line The knob cannot stay in such position when operated manually High short circuit capacity High short circuit capacity OkA for whole range thanks to the powerful e o e l e A Poured into line electric arc extinguishing system Long electrical endurance more than 4000 cycles thanks to quick making mechanism Knob padlock device Mcb knob can be locked either at on position or at off position to prevent unwanted operation of the product Specifications Characteristic curve Number of poles 1 1P N 2 3 3P N 4P 100 6000 Rated voltage AC 240 415V 60 4000 40 2000 123456 l0 1620253240506 Rated current A 20 1000 80 100 10 600 T Tripping curve B C D 6 400 E 4 200 ai 90 E nonR ciment ase aed Thelmalt ippon capacity Icn 1 60 12 Rated service short circuit 7500A ee id braking capacity Ics 20 Ra
30. ary switch amp alarm switch Rated operational current 230V 3 5A AC11 duty 415V 2A Mechanical lifespan 2000 operations Terminal capacity 0 75 2 5mm Weight 0 04kg EA Dimensions Characteristic curve IEO 898 BS 3871 PI Millisecconds Seconds Minutes e 5 www china suntree com 24 SBKN MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 63A 1P 1P N 2P3P3P N 4P New type for LS company Custom made othe model LSN MCB Application LSN mini circuit breaker is widely used in building commercial and industrial installations up to 63A 230 400V a c and 220 440V d c mainly for cable and conductor overload and short circuit protection It can also be used as current limiting circuit breaders and optical position indicator which indicates ON OFF position The tripping characteristics cover B C D according to EN 60898 Rated short circuit breadking capacity up to 10kA The color of control levers is in accordance with the colors offuses with screw base This product has wide range of accessories available in cluding auxiliary and relative switches undervo ltage releases and shunt trips busbars labels etc It is possible to be interconnected with switch discnnectors and with residual current circuit breakers by means of busbars It is possible to be locked and sealed in OFF or ON position Specifications Type LSN Standards EN IEC60898 Num
31. ave the function of high current limit 9 Protective grade IP20 Specifications Rated voltage Un Rated In Rated frequency Rated breaking capacity Energy limiting class Tripping characteristic Cross section of connecting lead Isolating class Mounting on the rall Build in width Standards Certificates Tripping characteristics 230 400V 6 63A 50Hz 4 5 6kA 3 B C D 1 25mm B EN60715 EN 50022 18mm pole IEC 60898 EN 60898 CE CB SEMKO RoHS Characteristics Test Current Tripping time t x 1h In x 634 B C D 1 13In t x 2h In gt 63A t lt 1h In x 634 B C D 1 45In t x lt 2h In gt 63A 1s t 60s In x 324 B C D 2 55ln 1s t 120s In2 32A B 3In C Sin t x 0 1s D I OIn B 5In 10In t lt 0 ls D 20In Result NO tripping Tripping Tripping No tripping Tripping Curve Tripping time 1 13xl 11 www china suntree com SMC MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword Max current 125A 1 2 3 4 Pole Breaking capacity 4 5 6 10kA SNC 125H MCB Application SNC 125H high breaking capacity circuit breaker is used for AC 50 60Hz single pole 230V or two three four pole 415V circuit for protecting the circuit that overload and short circuit may take place It can be used in lighting and electric motor distribution system Mean while it is applicable to an unfrequented switch over the electric apparatus and lighting circuit under normal condition Breaking ca
32. ber of poles 1P1P N 2P3P3P N 4P Tripping characteristics B C D Rated current In 6 63A Rated operating voltage Ue 230 440V A C A8V D C Max operating voltage Umax 253 440V A C 52V D C Rated frequency fn 50 60Hz Rated short circuit breaking forl 6A 32A Icn 8kA capacity EN60898 forl 40A 60A Icn 6kA Characteristics curves ENS kD Mox B oo ooo O Min Operational time 96 Sec ooo o o oo9 S o BOO v BROOA N FOOD o oo o SE SEP 2 3 4 567890 15 20 30 40 50 70 100 Multiple of rated current 25 www china suntree com LSN MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 634 1 2 3 4 Pole Similar Hager Breaking Capacity 4 5 6 10kA variety complete SMY SMT SMU SMW MCB Application SMY SMT SMU SMW mini circuit breaker is mainly suitable for overload and short circuit protection It is especially used for illumination and distribution in industry and commerce It is of pleasing outlook amp high breaking capacity etc Its frame and parts adopt plastics of light weight reliable performance high inflammable resistance and shock resistance for long service life It is mainly used for overload and short circuit protection within the circuit of AC 50 60Hz rated voltage of single pole up to 230V Two three or four pole up to 400V It can also be
33. current A 1 3 5 6 10 16 20 25 32 40 50 63A Characteristic Curve IEC60898 Rated Breaking Capacity 3kA 4 5kA 6kA Electrical life gt 6000 times Mechanical life 20000 times Tropicalizes Treatment 2 RH95 at55 C Characteristic curve x TYPEC TYPED 10000 Son 5000 bons SA Thermal tripping N 2000 1000 _ m i ii Thermal tripping 200 200 100 i 50 FI 20 a 10 i 5 A Electromagnetic 2 Ay pisa Electromagnetic a gt Tripping 0 2 T 0 1 E 0 05 RT 0 02 a 0 01 aS E nd 0 005 xq ne 0 002 s 0 001 v 05 1 2 345 7 10 2030 50 70 100 200i in i et i Outline and installation dimensions 7O ol N zi QD oo 15 www china suntree com 10 SCB2 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 63A 1 2 3 4 Pole Russian market selling Similar IEK EKF Arch design SMC MCB Application Miniature Circuit Breakers MCB which can be used in Low Voltage electrical installations to protect conductors switchgear and electrical equipment in general against overloads and short circuits Function e All the machines meet the standards of IEC and GB e They can be installed in the track of 35mm of IEC e They h
34. d short circuit protection It is especially used for illumination and ls 9 distribution in industry and commerce It is of pleasing out look light d weight reliable performance high breaking capacity etc Its frame and parts adopt plastics of high inflammable resistance and shock resistance for long service life It is mainly used for overload and short circuit protection within the circuit of AC 50 60Hz rated voltage of single pole up to 240V or two three four poles 415V It can also be used for an unfrequented switch over of the circuit and illumination under normal conditions S5SL6 Series S5SJ6 Series Specifications Frequency 50 60Hz Rated voltage 240 415V AC Rated breaking capacity 6000A Rated frame current 63A Rated trip current 2 4 6 10 16 20 25 32 40 50 63A NO of pole 1P 2P 3P4P Characteristic curve 0S Ais jen 6 aH i Thermal tripping un g E a 3 o0 amp a 40 g Be i N E 10 Electromagnetic 9 6 ippi D tripping n 4 2 1 TX eae a c 0 04 0 02 0 01 I 2 3 4 5 6 8 IO 15 2030 Multiple of raed Cuttent eo N Z 7 se tezei ea ea le Eee age PS eee ee zis ee www china suntree com 20 S5SJ6 S5SL6 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword Max current 100A 1 1P
35. d Its installation uses with guide Its case and Loue items are adopted with high fire resistant and shockproof plastics nam The product with long life Is mainly used in AC 50 60Hz single pole MTS Series Manual Tramsronmswiten 230V or two three four pole 400V circuit for overload and short circuit protection as well as for unfrequented on and off switching e e 2 9 9 9 electric equipment and lighting circuit in normal case The product complies with EN IEC60898 3 p BA Wi eas SC45 Seri Specifications Type Rated current A Pole NO Voltage V Breaking capacity A 1 2 3 4 6 10 16 1 230 415 6000 4500 20 25 32 40A 2324 400 1 230 415 50 63A 4500 3000 2 3 4 400 1 2 3 4 6 10 16 1 230 415 6000 4500 a 20 25 32 40A 2 3 400 1 230 415 50 63A 4500 3000 2 3 4 400 1 2 3 4 6 10 16 1 230 415 D 4500 3000 20 25 32 40A 234 400 i 1P 2P 3P 4P Weight g 102 208 308 408 e Complete accessories Dimensions Characteristic curve Short circuit Prospective short circuit current peak value Prospective Short cXcuit energy B type Ctype D type Current limiting peak value Current limiting short circuit energy times OS I 2 3457 10 2030 5070100 200 IK 0 2ms 10ms www china suntree com 08 SC45 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Orange handle Distribtuion Board Mount Arch design SC48 MCB Application SC48 series circuit break
36. d and short circuit Mean while they are also used in turning on off the electric apparatus and lighting circuit under the normal condition Specifications NO of Pole 1P 1P N 2P3P3P N 4P Rated voltage 230V 415V Mechanical life 4000 times Electrical life 10000 times Rated current 1 2 3 6 10 16 20 25 32 40 50 63A Protective grade IP20 Breaking capacity 6kA Characteristic curve 10000 10000 5000 5000 h 1h 2000 2000 1000 1000 500 500 200 200 l 100 _ 100 A 50 ZI 50 TI 20 ie 20 Ej 10 Ey 10 B 5 B 5 s 2 s 2 1 1 0 5 0 5 0 2 0 2 0 1 0 1 0 05 0 05 0 02 0 02 0 01 0 01 0 005 0 005 0 002 0 002 000195 1 2 3457 10 20 30 5070100 200 000195 1 2 3457 10 20 30 5070100 200 B In C I In www china suntree com SIC60 SIK60N MCB SHANGHAI XINCHI ELECTRIC CO LTD Miniature circuit breaker accessories Muller Series Legrand Series www china suntree com 4 Miniature circuit breaker accessories SHANGHAI XINCHI ELECTRIC CO LTD Miniature circuit breaker accessories SC65 SC60 Series OF SC65 SC60 Series MV MN MV SL7 Series 5 www china suntree com Miniature circuit breaker accessories SHANGHAI XINCHI ELECTRIC CO LTD Miniature circuit breaker accessories SC45 Series
37. e 1P N 6 10 16 20 25 32 40A 30 100 300 500mA AC230 240 V 50Hz Up to 6 mm2 cables the magnetic release operates between 5 and 10 In lt 0 3s 4500A gt 4000 IP20 IEC61009 Wiring diagram 82max 20 30 5070100 200 www china suntree com 54 SCDB3LE RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 32A 1P N Pole 36mm The color safety instructions box SDZ30L RCD Application SDZ30L leakAge protective breaker is used in the single phase residence circuit of AC 50 60Hz rated voltage 230V used as electron shock protection It can protect civil electron circuit from overload and short circuit This product has advantages of small volume high breaking capacity zero and live wire are cut off at the same time also protecting person from electric shock when the live wire connected opposite This product conforms to IEC61009 GB16917 Standards Specifications 1 i ht I FP PF E it l x e J F i I x N E aa Rated Current Rated LeakAge Rated LeakAge Rated LeakAge Breaking Rated Current A No of Pole Rated Voltage A Non Operating of Frame Operating Breaking Time Capacity A Current 6 10 16 20 25 32 1P N 230 32 30 15 lt 0 1s 3000 Overload trip characteristic Rated Current A Rated Voltage A Lim
38. e 6000 e Mechanical life 16000 e Dimensions 41 5 x 32 x 33 e Gross weight 24kg Net weitht 23kg www china suntree com 34 S MCB Series miniature circuit breaker Supply type A and type AC RCD Tripping is reliable and stable No malfunction SHANGHAI XINCHI ELECTRIC CO LTD What a lifesaver Safety in numbers The SUNTREE range continues to grow Since the late 1997s XINCHI has led the way in the development of Residual Current Device RCD technology commonly known as the Safety Switch with a product range that is constantly increasing and being improved to meet the needs of consumers So whether you require fixed or portable protection in the home workshop or workplace XINCHI has the Lifesaver for the job Live appliance Earthed metal object Setting a high standard XINCHI is an industry leader when it comes to electrical products Over the years the company has continually set high standards for electrical products in Australia and around the world The Safety Switch has been a major contributing factor in the continued reduction of electric shocks and electrical safety hazards Standards XINCHI s Lifesaver range provides all homes and workplaces with the equipment to comply with the RCD requirements of AS NZS 3000 Wiring Rules In addition to this it is worth noting in December 2010 the NSW Government announced that by 2014 all businesses will be required to protect workers with Safety S
39. e normally one month test button should be pressed noce in a state of making the circuit to check whether the function of RCBO is normal and reliable press test button once the RCBO can break off noce If abnormal it should be unloaded and sent to the manufacturer to repair e RCBO can not be wetted or soaked by rain snow or water during the course or transportation storage and usage Dimensions 37 www china suntree com SDRNL Mini RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1P 1P N 2P 3P 3P N 4Pole 30 100 300 500mA Distribtuion Board Mount Small shell 32A Large shell 63A SC45L RCD Application SC45L earth leakAge circuit breaker is used for the protection against electrical leakAge in the circuit of 50 60Hz rated voltage single phase 9 e 9 e 230V 3 phase 415V rated current up to 60A When somebody gets an E aam electric shock or the residual current of the circuit exceeds the fixed 25 NE Er n i value the RCD can cut off the power within the time of 0 1s automatically i ae protecting the equipment from the fault resulted by the residual current TE m EX BB With this function the RCD can protect the circuit against overload and r 3a ee ea short circuit or can be used for the unfrequented switch over of the circuit L Qq r under normal conditions It conforms to IEC60898 amp IEC61009 1 Specifications LeakAge Action LeakAge Dead LeakAge Action Rated Voltage V P
40. entually break down the entire power plant This is why Surge Protection Device is developed The induced surge currents are diverted to the earth before they can reach the equipments connected to the downstream power network while the overvoltages are kept to a harmless level and the equipments are kept running safely and normally With Protection These Surge Protection Devices are recommended for protecting any equipment connected to main power supplies The selection of the product type is done by taking into account the exposition degree to lightning of the area installation in isolated or metropolitan area cost sensitivity level of the equipment the neutral earthing system and the installation method Bi INSTALLATION EXAMPLE HV Lightning Distribution Panel peat II LV SPD Main Panel Distribution Panel Power Line er Overvoltage Level Class Class Il Class III Protection Class SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1P 2P 3P 4P NPE Similer OBO Imax 100kA IEC6164 1 SUP1 D C BSurge protective device Application SUP1 D C B 5 series surge protection device in short SPD alias surge suppressor surge arrester is suitable for TN S TN C S TT IT etc power e O supply system of AC 50 60Hz lt 380V installed on the joint of LPZ1 or Brai i 15 A LPZ2 and LPZ3 it s designed according to IEC61643 1 GB18802 1 it Sm Sn Sm n adopts 35mm standard rail there is a
41. er is used in lighting distribution system or motor distribution system for protecting overload and short circuit The product is novel in structure light in weight reliable and excellent in performance Is mainly used in AC 50Hz 60Hz single pole 240V or two three four pole 415V circuit for overload and short circuit protection as well as for unfrequented on and off swit ching electric equipment and lighting circuit in normal case The product complies with EN IEC60898 Specifications Pole NO 1 2 3 4P Breaking capacity kA 4 5 6kA Rated temperature 40 C Rated voltage 240V 415V AC Rated current 1 2 3 4 6 10 15 16 20 25 32 40 50 63A Electrical life 6000 times Mechanical life 20000 times 1P 2P 3P 4P Weight g 102 208 308 408 e Complete accessories Dimensions Characteristic curve 10000 5000 H Short circuit Prospective short circuit current peak value 2000 1000 500 200 100 Prospective Short cXcuit energy B type C type D type 0 05 0 02 0 01 0 005 0 002 0 001 Current limiting peak value Current limiting short circuit energy O 2ms 10ms times i5 I 2 345 7 LO 2030 5070 00 200 V IK 09 www china suntree com SCA8 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Commonly used products of the southeast Asian market SCB2 MCB Specifications Poles 1P 2P 3P 4P Rated Voltage V 230V 400V Rated
42. fixed value the RCD can cut off the power within the time of 0 1s automatically protecting the equipment from the fault resulted by the residual current With this function the RCD can protect the circuit against overload and short circuit or can be used for the unfrequented switch over of the circuit under normal conditions It conforms to IEC60898 amp IEC61009 1 Specifications Standard IEC60898 amp IEC61009 1 Rated Voltage Un 230VAC 415VAC Rated Current In 1 63A 30 100 300 500mA Rated Residual Operating Current l A n Rated Residual Non operating Current l no Rated Current off time lt 0 1s Min Value of Rated Operating and Breaking Capacity Im 63A Electrical life not less than 4000 times Mechanical life not less than 20000 times Installation On symmetrical DIN rail Dimensions L 67 5 Operating principle bL L e LA i A Bm em N N r E a eel g at ee aaa nes 8 SEESSESNE Se OOS 5 5 65 oL oo JOL og EJ S or A SL7LE 1 2 SL7LE 2 2 SL7LE 3 3 SL7LE 3 4 SL7LE 4 4 41 www china suntree com SL7LE RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 50A 1 N Pole 36mm Consumer Unit Mount Distribtuion Board Mount SPFIM series RCD Application The RCD apply to the circuit of AC 50Hz w
43. g Impulse withstand test voltage 6 6 Frequency Hz 50 60 50 60 Isolation application Yes Yes Breaking IEC61009 1P N 230 240V 6 6 Capacity kV Mechanical endurance 20000 20000 20000 Electrical endurance 10000 10000 10000 Auxiliary contacts alarm Auxiliary contacts alarm Add on devices contactes undervoltage contactes undervoltage release shunt trip release shunt trip Teminal capacity 25 35 35 Dimension H x D x W 86 x 68 x Wmm mod 18 18 18 www china suntree com 93 SE9 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword IEC61009 SC45L new type Curve C Breaking Capacity 4 5kA Sensitivity 30mA SCDB3LE RCD Application SCDB3 LE electronic type residual current operated circuit breakers combine the following functions e Protection of circuits against overload currents 9 Protection of circuits against short circuit currents 9 Protection of users against indirect contact Additional protection for users against direct contacts 30mA m 9 Protection of electrical installations against insulation faults fire hazard etc ea e Isolation e 9 Specifications l a l9 lt gt BCDHX E a2 ECD MXE b5 masses CM cu ts ze reda OF No of Poles Rated Current In Rated Operating Current l A n Rated Voltage Un Rated Frequency Connection C curve Residual Current off time Short circuit Capacity Icn Endurance Protection Degree Standard Dimensions Tripping Curv
44. gle pole up to 415V 3 Pole 50Hz for x protection of overload short circuit and for circuit changeover in vm lighting system Breaking capacity is 3kA It is in dictator can be used vo e T i gi d 2 mms t indicat Il t d indust tem circuit indication in illumination and industry system SWA40 ska SK2 Specifications Rated current 1 3 6 10 16 20 25 32 40A Rated voltage 230V 415V AC Breaking capacity 3000A Mechanical life 10000 times type Thermal trips Magnetic trip Tripping characteristic Ratedtripping current A Time of rated tripping current L1 L32 1 32 1 13ln 1 45In PSSA lhl 3In Sin Starting state From cold state From cold state From cold state From cold state From cold state TR 1sec lt Tripping time gt Thr lt thr gt 0 1sec lt 0 1sec t 60sec G type Thermal trips Magnetic trip Tripping characteristic Ratedtripping current A Time of rated tripping current G1 L32 1 32 1 13In 1 45In 2 55 n 3ln Sin Starting state Tripping time From cold state From cold state From cold state From cold state From cold state 1sec lt t 60sec gt 1hr 1hr gt 0 1sec lt 0 1sec www china suntree com 28 SW40 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword Max current 63A 1P N 18mm Consumer Unit Mount Distribtuion Board Mount SDPNa MCB Application SDPNa mini circuit breaker applies to locations such as industrial commercial high rise and civil residence with AC230V and below
45. ilding and The item is a durable protection that substitutes the traditional fuse element and can be used in each fuse socket with E27 thread ac for protection of circuit terminals against overload and short circuit N e Y 1 cording to DIN 40440 Installing 101 breaker should be screwed into the fuse socket instead of fuse bed and cartridge fuse Instruction to use The S101 breaker is on after the black push button has been pressed and is off when the red push button is pressed In case of emergency action of the 101 breaker the failure should be found and eliminated The black push button is pressed again then the breaker is ready for operation type Rated current 2 25A 32A Pole NO Single pole Single pole Rated voltage 250 380V 250 380V Rated short circuit Expected current in testing circuit A 3000 3000 making Power factor for testing circuit 0 65 0 70 0 75 0 80 Dimensions 27 www china suntree com 101 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 40A 1 2 3Pole Consumer Unit Mount Similar Siemens Custom made K series SW40 MCB Application SWAO seriec miniature circuit breaker has small size light weight D li 9 9 novel structure and excellent performance They are mounted in the i illuminating distribution board and used in guest houses block of co l flats high buildings squares railway stations plants and enterprises etc in AC circuits 230V sin
46. ions 4P 108 3P N 108 3P E 3P 81 AP 2P 54 1P 1P N 27418 2P 54 54 3P 81 81 3P N 81 108 4P 108 108 www china suntree com SC45L 125H RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 63A 1P1P N 2P 3P 3P N 4Pole Consumer Unit Mount SC65L SC60L RCD Specifications Rated Voltage Rated current Rated frequency Rated breaking capacity Tripping characteristic Rated residual current Standard Wiring diagram 230V 415V 9 6 63A Da c 50Hz 10 6kA B C D A 30mA 50mA 300mA 500mA tel 9 9 IEC60898 amp IEC61009 1 Single pole Triple pole Triple pole Four pole 3 un Double pole Double Line T i P H x Double Line Triple Line Four Line Four Line SC65L 1 2 SC65L 2 2 SC65L 3 3 SC65L3 4 SC65L4 4 Dimensions SC65L 1 2 aa OLO ii eae _ amp j SC65L 2 2 SC65L 3 3 SC65L 3 4 SC65L 4 4 www china suntree com 40 SC65L SC60L RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Consumer Unit Mount Distribtuion Board Mount SL7LE RCD Application SL7LE earth leakAge circuit breaker is used for the protection against electrical leakAge in the circuit of 50 60Hz rated voltage single phase 230V 3 phase 415V rated current up to 60A When somebody gets an electric shock or the residual current of the circuit exceeds the
47. ited Time Press gang Result Start State Note 1 131 All pen non trip cold state 1 45In All t lt 1h trip heat state The current rise steadily to a fixed value within 5s 2 55In All 1 t 60s trip cold state Sin All t gt 0 1s non trip cold state Open the supplementary switch connect the power 10In All t lt 0 1s trip cold state Open the supplementary switch connect the power Dimensions Characteristic curve 10000 5000 IH 2000 1000 500 200 100 50 20 10 0 5 0 1 0 05 0 02 0 01 0 005 0 002 0 001 OS 2 845 7 I rXaeko 7 0 100 200 I 1K 5 www china suntree com SDZ30L RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 40A 1 N Pole Consumer Unit Mount Distribtuion Board Mount SDPNL 40 RCD Application e Protection against the effects of earth leakAge overload and short circuit currents loa is e 2P switching of ph amp N Phase only protected against overloads and 0 24 short circuits b d e n commercial industrial and domestic electrical distribution systems N vL Note It can t be used as the sole means of providing protection ES e against direct contact It The RCBO incorporates a residual current operated electromagnetic k ne e release which operates without any auxiliary source of supply to open Ver a circuit automatically in the case of an earth leakAge fault between phase and earth greater than or equal to in The RCBO combined e Complementary pro
48. ith rated voltage up to 400V rated current up to 50A power supply neutral point ear thing Main use in protect of person get an electric shock and protect the building s circuit devices over current it also can protect the earthing fault The RCD is according with IEC61009 1 standard Specifications Frame case Add grade rated Pole X neutral current Inm wire A 50 1 N 40 1 N Dimensions Curve Rated residual Rated residual non operating operating current current n mA n mA 6 10 16 20 30 50 100 300 25 32 40 50 6 10 16 20 30 50 100 300 25 32 40 Rated short circuit breaking capacity Voltage Breaki 2 d n cos O V capacity 230 1000 0 5 230 Rated residual switch on breaking capacity A 3000 Over current instantaneous release type B C D D type In up to 40A B C D D type In up to 40A www china suntree com 42 SPFIM series RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4Pole A amp AC curve Electronic and electromagnetic SF SNF 7 RCD Application 1 2 5 H The RCD can cut off the fault circuit immediately on the occasion 9 9 9 0 of shock hazard or earth leak age of trunk Line Thus it is suitable to em avoid the shock and fire caused by earth leakAge 5 The RCD is mainly suitable for use using in variety of plants and ret enterprises construc
49. many moulds Passed CE TUV IEC CB Provide miniature circuit breaker lockouts SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 1 N 2 3 3 N 4 Pole IEC60947 2 SAA CE TUV CB Nemko Square indicator window SL7 63 MCB Application SL7 63 have protective function as shortage as overload and are used in lighting distribution system in commerce and dwelling and protect fractional electric motors And they also have many merits of high protective grade up to IP20 high breaking capacity reliable sensitive action convenient multi pole assembling long life ect They are mainly adapted to the circuit of AC 50Hz 250V in single pole 415V in double three four poles for protecting overload and short circuit Mean while they are also used in turning on or off the electric apparatus and lighting circuit under the normal conditions We supply more comprehensive security SAFE LOCK Detailed installation process as follow Push up Hanging into the locks Applies to all SL7 products Dimensions Characteristics curves Transparent shell Specifications Standard Rated current Rated Breaking capacity Characteristic curve Max fuse that can be connected to Selective grade Working ambient temperature Enclosed protective class Electrical life Mechanical life EN60898 IEC60898 IEC60947 2 1 63A 6 10kA IEC60898 0 5 63A 6 10 15kA IEC60947 2 0 5 63A B C D 100AgL gt 10kA
50. nt off time lt 0 1s Breaking Capacity kA 6000 Rated Conditional Short circuit Current lcn 500A Endurance In 25 40A Inc 1500A In 63A Inc 3000A Short circuit Capacity Icn On load 2000 cycles off load 2000 cycles Endurance gt 4000 Dimensions 35 5 Operating principle Ree m mge LI L2 L3 N www china suntree com SID RCD 4a SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4Pole A amp AC curve Electronic and electromagnetic SIDN RCD Application SIDN Residual current circuit breaker without over current protection conforms to the standards of IEC61009 1 BS4293 etc It is used in the circuit of AC 50 60Hz single phase 230V three phases 415V in industrial amp mining enterprises Commercial buildings and housing for protection of personal electric shock hazard and also can used for unfrequented switch over circuit under normal conditions Specifications B m e e _ B gt e za mom Improved Standard Rated Voltage Un Rated Current In Rated Residual Operating Current l A n Rated Current off time Mini Value of Rated Operating and Breaking Capacity Im Rated Conditional Short circuit Current Inc Endurance Installation Dimensions IEC61009 1 BS4293 2Pole 230VAC 4Pole 415VAC 25 40 63A 30 100 300 500mA 05 An lt 0 1s 1kA In 25 40A Inc 1500A In 63A Inc 3000A On load 2000cycles off load 20
51. o of poles 1 pole 2 pole 3 pole 4 pole This breaker is Plugin installation mode can be installed on the installation rail Power frequency withstand voltage after being in condition fo hot and humidity performance this breaker can bear 2500V power frequency withstand voltage test for 1 min and without any insulation flashover and breakdown phenomenon Mechanical and electric life mechanical life is 2000 times electric life is 6000 times Specifications X 5HL 350 100 CE hy k i arma L ge x j PP Rated Voltage Rated current Rated breaking V A capacity 1 1mn 3ln 230 415V 32 63 80 100 COS Q 0 65 Dimensions Rated short time with Rated short circuit Rated fuse short stand current A on off capability circuit current KA 30In t gt 0 1S 200t 1s 20 GOS oO 05 e o ee SZ amp di SEZ HE ime sei Ele tint ian ie ESI e E ER 71 5 1P 74 2P 3P 4P 68 1P 71 5 2P 3P 4P 125 www china suntree com 32 SHL30 Switch disconnectors SHANGHAI XINCHI ELECTRIC CO LTD S MCB Series miniature circuit breaker STHQL Specifications e Number of Poles 1 2P 1P 2P 3P 4P e Rated current A 6 10 15 20 25 30 40 50 60 70 80 90 100 e Rated voltage V 110 220 1P 240 415 2P 415 3P e Rated breaking capactity A 3000 e Electrical life 6000 e Mechanical life 20000 939 STQL SD Specifications e Number of Poles 1P
52. ole number Rated current A z Y Current mA Current mA Time s 1 10 230V 1P 30 15 15 32 lt 01 415V 2 3 4P 40 63 100 50 Wiring diagram Gel eu SC45L 1 2 SC45L 2 2 SC45L 3 3 SC45L 3 4 SC45L 4 4 www china suntree com 38 SC45L RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 100A 1P1P N 2P 3P 3P N 4Pole Distribtuion Board Mount Assembled RCD SC45L 125H RCD Application SC45L 125H is suitable for the circuit of 50Hz rated voltage 9 230V 415V and rated current up to 100A It has the earth leakAge go Um overload short circuit protect function And it can also add over uui voltage protect function It is mainly used in building illuminating and electrical distribution system PN O B Specifications 9 9 9 TEE Rated no Voltage Rated frame NO of Neutral Rated breaking Pata operation Tripping Tripping V current A Pole pole capacity luca cos attics current In time s type current A 230 1 N 40 10000 0 5 30 15 lt 0 1 C 230 2 50 10000 0 5 50 25 lt 0 1 C 415 3 63 6000 0 5 100 50 lt 0 1 C 230 415 3 N 80 6000 0 5 200 100 lt 0 1 C 230 415 4 100 10000 0 5 300 150 lt 0 1 G 230 ee 1 N 40 10000 0 5 30 15 lt 0 1 D 230 2 50 6000 0 5 50 25 lt 0 1 D 415 3 63 6000 0 5 100 50 lt 0 1 D 230 415 3 N 80 6000 0 5 200 100 lt 0 1 D 230 415 4 100 0 5 300 150 lt 0 1 D Outline and installation dimens
53. oltage 230V 415V Mechanical life 4000 times Electrical life 10000 times Rated current 1 2 3 6 10 16 20 25 32 40 50 63A Protective grade IP20 Breaking capacity 4 5 6 10kA e Complete accessories Dimensions Characteristic curve 10000 2a 19 5000 SA s 1 6 131 9 2000 1000 J i 1 29 500 8 0 E EG 100 B 50 fF B 10 IE 5 LO s 2 LO N SN 0 5 Eo H 0 2 i LO LO 0 1 al LO S 0 05 TE Sai EL uem 0 02 i 0 005 0 002 eA SS eA SS 0 0105 4 2 3457 10 20 30 5070100 200 000158 1 2 3457 10 20 30 5070100 200 p B I In C I In 13 www china suntree com SC65 SC60 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 1 N 2 3 3 N 4 Pole Similar Schneider High breaking capacity New type SIC6O SIK6ON MCB Application SIC60 MCB have protective function of shortage and overload m and are used in lighting distribution system in industry commerce 3 and dwelling and protecting fractional electric motors And they Bm also have many merits of high protective grade up to IP20 high breaking capacity reliable system isotone convenient multiple em assembling long life etc They are mainly adapted to the circuit of AC 50Hz 230V in single pole 415V in double three four poles for h protecting over loa
54. one of the most professional manufacturers producing low voltage and high voltage electrical products we mainly produce circuit breakers contactors and thermal overload relay Fuse Switch disconnectors ATS Distribution box SPD SSR Transformer Relay Button and signal lantern Regulator Switching power supply and solar connector DC circuit breaker solar cable DC Switch disconnectors DC combiner box and so on As an ISO9001 2008 certified company we have obtained many certificates Such as IEC60947 IEC60898 CB SAA TUV CE SONCAP RoHS Nemko PCT CCC etc Stability expertise and technological innovation are the corner stones of the company s business strategy Aiming at reliable product quality and highest customers satisfaction we are consistently deep ening enterprise inner reform and fully carry out quality guarantee system Such as the quality of all products is insured under PICC fully guaranteed consumers rights With special cultivation of employees high investment on production facilities and R amp D and wide range of products we advocate technology innovation business honesty and trust and always put quality as our basic principles trying to develop into a world class electrical manufacturer with constant efforts Technology Innovation Famous in the world www china suntree com CEL Oh E o AES lt a apa o gt EAT 224 Ui DC switch for solar system Accept OEM amp ODM Design and improve
55. pacity is up to standard of IEC60947 2 Specifications Rated current Rated voltage Electrical life Mechanical life 32 40 50 63 80 100 125A 230V A15V AC 6000 times 20000 times C O NO of Pole 1P 2P3P4P 1P 2P 3P 4P Weight g 180 360 540 720 Custom made 32A 40A 50A Dimensions Characteristic curve t s 10000 5000 IH 70 2000 1000 500 200 100 50 20 10 5 B type ies LO Ctype zi D type 0 1 0 05 0 02 0 01 _ eee 0 005 Sn Rass ES 0 002 OPTOPOPTOP 44 16 zii 0 5 2 345 7 10 2030 5070100 200 I IR E S www china suntree com 12 SNC 125H MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Similar Schneider High breaking capacity SC65 SC60 MCB Application SC65 SC60 have protective function of shortage and overload _ and are used in lighting distribution system in industry commerce T O and dwelling and protecting fractional electric motors And they also have many merits of high protective grade up to IP20 high i breaking capacity reliable system isotone convenient multiple i x assembling long life etc They are mainly adapted to the circuit of amp AC 50Hz 230V in single pole 415V in double three four poles for M protecting over load and short circuit Mean while they are also used in turning on off the electric apparatus and lighting circuit under the normal condition Specifications NO of Pole 1P 2P 3P4P Rated v
56. peraction 10 000 Terminals IP20 Protection degree Housing IP40 Operqating temperature C 25 55 Terminal size mm 0 75 25 Tightening torque Nm 2 Dimensions Characteristics curves 52 5415 d Characteristic B un Characteristic C ieee 01 on je da B Ba d unc 30 iE 13 2 03 456 810 15 2 om e E DS gt O multidescf rateclauneri www china suntree com 22 S250 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 4 63A 1 1P N 2 3 3P N 4P Consumer Unit Mount Similar Hawes SHL MCB Application SHL products of domestic power distribution box have come out The high quality and high function circuit breaker used in domestic used in domestic power distribution box is looking for ward to your selection and application Specifications Number of poles 1 1P N 2 3 3P N 4P Rated voltage AC 240 415V Rated current A 2 56 10516 20725 32740 50763 Tripping curve B C D Rated short circuit capacity Icn 6000A Rated service short circuit braking capacity Ics 7500A Rated frequency 50 60Hz Energy limiting class B Rated impulse withstand voltage 4kV Electro mechanism endurance 4000 Connection termina Screw terminal Connection capacity rigid conductor up to 25 mm Fastening torque 2 0Nm Installation On symmetrical DIN rail 35mm Manufacture standard IEC60898 12003 1858828 1996 Characteristics curves Thermal Tripping Magnetic Tripping As per No Curve ew Tripping Time Hold Hold Time tripping
57. se time ns lt 25 Invalidation indicating Aging invalidation white Normal red invalidated Protection degree IP20 Application Protection for incoming line Remote signal function Can be ordered Remarks Other max continuous voltage Uc should be customized Dimensions 118 5 65 www china suntree com SUP2 Surge protective device SHANGHAI XINCHI ELECTRIC CO LTD Keyword Imax 120kA 1P 2P 3P 4P Arch design Similar CITEL Standard rail 35mm Fiber glass reinforced plastic SUP3 Surge protective device Application o SUP3 series surge protective device hereinafter called SPD is suitably used in the IT TT TN C TN S TN C S and etc power supplysystem of AC 50 60Hz rated voltage up to 380V to protect from directand indirect lightning impulse and other transient over voltage As ini per the conditions of IEC61643 1 1998 02 standard Class surge n a i protective device it is category B surge protective device Operation Elements Single pole structure single pole or three poles combined SPD available SPD has built in disconnecter when SPD is invalid due to overheating or breakdown the disconnecter can automatically separate SPD from the network meanwhile send an indication signal e The visible window show white color in normal service if to be separated from network it will show red color It can adopt Kelvin wiring mode
58. so on protection functions the over voltage protection functions The over CT i ig i voltage protection function can also be provided upon requirements C wm They are mainly used to protect the buiding illumination and power 1x distrion system 9 ec ALIN H ww L Tm SAA 6kA SAA 4 5kA Specifications Breaking Times S mA Rated Voltage V Rated Current A IAn mA no mA lAn 21An 025A 500A A 240 6 10 16 20 25 32 30 100 15 50 0 1 0 05 0 4 0 04 3000 Normal Operation Conditions e Ambient Air temperature Ambient air temperature range from 5 C 40 C not exceeding 35 C averagely in 24 hours e Location installation location can not exceed 2000 meters above sea level e Air conditons Relative humidity in the installation palce can not exceed 50 when the air reaches the highest temperature 40 the average minimum temperature when it is the wettest can not exceed 25 C Relative humidity not exceeding 90 e Installation conditions Magnetic field outsid the installation place can not exceed 5 times of the site of terrestrial magnetism in all directions Normally speaking RCBO should be mounted vertically If the operation handle puts through power source upward there should be no notable impact and vibration in the installation place e LeakAge protection function of RCBO is tested and adjusted by the manufacture users can not open the products at random during usage e After using RCBO for a certain tim
59. tection against direct contact e Protection for the installation against insulation faults Specifications Type SDPNL 40 No of Poles 1P N Rated Current In di 2523541055105 16 20 25 32 420A Rated Operating Current l n 30 100 300 500mA Rated Voltage Un AC230 240 V Rated Frequency 50Hz Curve BE Residual Operating Current Scope 0 5 An 1An Residual Current off time lt 0 3s Short circuit Capacity Icn 6000A Endurance gt 4000 Protection Degree IP20 Standard IEC61009 Dimensions www china suntree com 56 SDPNL 40 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 10 25A 1 N Pole Similar ABB Variety complete SDS941 SGS260 RCD Application Buidings both residential and commercial Function protection against both overload and short circuit a M currents and earth falt currents additional protection against direct 2e contact thanks to n 30A SGS260 Series Specifications No of Type cla Nominal fault current Nominal current class poles ye I A nmA In A Icn 4 5kA B characterisics 1P N AC 30 20 25 Icn 4 5kA C characterisics 1P N AC 30 20 25 Icn 6kA B characterisics 1P N AC 30 20 25 Icn 6kA C characterisics 1P N AC 30 20 25 57 www china suntree com SDS941 SGS260 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 40A 1 N Pole 18mm Belt line Distribtuion Board Mount SNLE RCD Application Selection Rated residual opera
60. ted frequency 50 60Hz 10 Electromagnetic Energy limiting class 3 E NE EE 5 Rated impulse withstand PES i 4kV B voltage s I Electro mechanism 0 4 4000 2 gt endurance 209 Connection termina Screw terminal ei 0 06 Connection capacity rigid conductor up to 25 mm RE 0 01 Fastening torque 2 0Nm 0 006 S 15 2 3 4 5 6 8 10 15 2030 Multiple of raed Cuttent Installation On symmetrical DIN rail 35mm Manufacture standard IEC60898 12003 1S8828 1996 23 www china suntree com SIS 63 MCB SHANGHAI XINCHI ELECTRIC CO LTD Keyword 1 63A 1 2 3 4 Pole Similar ABB Variety complete S200 SH200 S230 S260 250 MCB Fa i e ee 9062 28 i i e TM P o Q p 9 SH202 Specifications Type S250S S250H S250S DC Standards IEC60898 IEC60898 2 Pole 1234 12 3 4 Tripping characteristics B CD B C C Tripping type Electro Magnetic Type 6kA 1 404 Rated breaking capacit Icu 6kA 50 63A 10kA pene 4 5kA 50 63A Rated current In 1 63A 50 63A 1 63A Frequency Hz 50 60 Mechanical Life no of operaction 20 000 no of o
61. ting current A n mA additional protection in the case of direct contact Tripping class AC class Tripping is ensured for sinusoidal alternating currents whether they be quickly applied or slowly increase Tripping curve B curve 3 5In protection and control of the circuits against voerloads and short circuits protection for people and big length cables in TN and IT systems C curve 5 10In protection and control of the circuits against overloads and short circuits protection for resistive and inductive loads with low inrush current Specifications Standard Type wave form of the earth leadage sensed Thermo magnetic release characteristic Rated current In poles Rated voltage Ue Rated sesitivity A n Electrical features Rated resdual making and breaking capacity A m Rated short circuit capacity Icn Break time under n Rated frequency Rated impulse withstand voltage 1 2 50 Uimp Dielectric TEST voltage at ind Freq for 1min Insulation voltage Ui Pollution degree Electrical life Mechanical life Mechanical Contact position indicator featrues Protection degree Ambient temerature with daily average lt 35 C Storage temperature Tmrminal connection type Terminal size top bottom for cable Terminal size top bottom for BUSBAR Installation Tightening torque Mounting Conection gt a a le BIND dai aa kV IEC EN 61009 1 AC B C 6 10 13 16 20 25 32 40 1P N 240 0
62. tion commerce guest houses and families It can pif ag be used in circuit single phase 230V three phase 415V 50 or 60Hz h m RCD is not suitable for use using in pulse system E T e e Specifications Standard IEC61009 1 Rated Voltage Un 2Pole 230VAC 4Pole 415VAC Rated Current In 25 40 63A Rated Residual Operating Current l A n Rated Current off time lt 0 1s Minimum Value of Rated Making And Breaking Capacity Im 63A Rated Conditional Short circuit Current Nc In 25 40A Inc 1500A In 63A Inc 3000A Endurance On load 2000cycles Off load 2000cycles Installation On symmetrical DIN rail Dimensions 35 Er WS We s 43 www china suntree com SF7 SNF 7 RCD SHANGHAI XINCHI ELECTRIC CO LTD Keyword 25 40 63A 2 4 Pole A amp AC curve Electronic and electromagnetic Integrated model SID RCD Application They have a residual current operated electromechanical release 2 9 oa 9 which operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakAge fault between d phase and earth greater than or equal to a threshold of 30mA 100mA 300mA or 500mA rt Specifications EE dere Standard IEC61009 1 Rated Voltage Un 2Pole 230VAC 4Pole 415VAC Rated Current In 25 40 63A Rated Residual Operating Current l A n 30 100 300 500mA Rated Residual Non operating Current l no 0 51 An Rated Curre
63. witches where reasonably practicable This new electrical standard will bring NSW in line with four other Australian jurisdictions SA WA NT and QLD all of which already have Safety Switch workplace provisions in place Protecting your equipment As well as protection from electrocution an RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth This protects appliances from costly damage and the installation from fire For total protection of your equipment RCDs must be used in conjunction with Miniture Circuit Breakers MCBs together with surge protection Protecting you When a power tool or appliance is in use your XINCHI Lifesaver continually monitors and compares the current flowing through the Active and Neutral circuits of the electrical installation In the event of a current flow to Earth an imbalance will occur If this imbalance is sufficient the XINCHI Lifesaver will cut the power in a fraction of a second www china suntree com 36 What a lifesaver SHANGHAI XINCHI ELECTRIC CO LTD Keyword 6 324A 1 N 18mm 30mA Breaking capacity 4 5 6 0kA SAA Certificate The RCD temperature rising is small No malfunction SDRNL Mini RCD Application ML i N SDRNL earth leakAge circuit breakers aremainly applied to the AC 50 60Hz 1Hz circuit rated 240V and 32A or below They have the o electric leakAge electric shock overload short circuit and