Home

ESP Ultima Zone Controller Manual LM-ZC

image

Contents

1. Zone Controller Press the button Actual room zone temperature will be displayed for several seconds then display will return to setpoint temperature During this period the blue LED on the button will flash indicating the room temperature is shown on the display To display the room zone temperature for 45 minutes press and hold button for 5 seconds Press any button to exit The room zone temperature display can be the temperature at the zone controller or at a remote sensor or the average of both depending on your installation set up 10 ZONE OPEN MODE ZActronAir 33m EE Ll ZONE COOL HEAT ESP AUTO orr max ZONE CONTROL Aj Em y TEMP SS amp ALETU Master Wall Controller Zone Controller Press the 2 button twice in quick succession until Fn appears on the display DP n indicates that the Zone Damper blade is in maximum open position Turning Off Zone Press the button to turn off the zone Alternatively press the designated zone button in the master wall controller It is not possible to control or adjust the temperature in this mode This zone temperature will now depend on the systems operating mode HEAT or COOL This mode has no control on room temperature your sensor is ignored in this mode A zone in OPn mode is like having a non temperature controlled ON
2. ActronAir E P pe ULTIMA AIR CONDITIONER ULTIMA ZONE CONTROL Operating Instructions Master Controller LM7 D Ultima Zone Controller LM ZC es N Please Read This Manual Congratulations on your purchase of an ActronAir air conditioning system This unit has been designed and manufactured with the highest quality standard in mind Please read this manual carefully and keep it for future reference ME e Copyright 2013 All rights reserve No part or contents of this book maybe reproduced or transmitted in any form or by any means without the written permission of Actron Engineering Pty Ltd GENERAL INFORMATION YOUR ACTRONAIR ESP ULTIMA SYSTEM IS A STATE OF THE ART PRODUCT with advanced Microprocessor Control that automatically controls and regulates conditioned air in each zone to provide year round climate control and comfort INSIDE THIS MANUAL You will find instructions for Zone Controller used with ActronAir ESP Ultima system Functions of the Master Controller LM7 D and LM24W in conjunction with ESP Ultima operation are also explained NOTE Basic and detailed functions of the Master Controller LM7 D and LM24W are explained in the operation manual 0500 121 supplied with your A C unit ACTRONAIR ESP ULTIMA SYSTEM is a highly advanced and efficient VAV system that lets you control the temperature of each zone It is also used in conjunction with ECM Electronically Commutated Motor Indoo
3. contact your installer Incorrect wiring or a broken circuit could also cause these symptoms FAULT CODES When E is displayed in the Master Controller or Zone Controller take note of the digits after E and contact your installer E3 System has detected less than 2 sensors Ultima requires at least 2 sensors in circuit or a remote sensor is short circuit E5 No Communication The system is constantly relaying information back and forth This indicates the communication is not happening Contact your installer to check your wiring and cable s integrity 13 14 THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK 19 E ActronAir Australian for air conditioning 1800 119 229 actronair com au Actron Engineering Pty Ltd ABN 34 002 767 240 HEAD OFFICE SYDNEY AUSTRALIA Printed in Australia Part No 0500 122 Version 03 130612
4. OFF zone damper Zone 1 cannot be put in OPn mode 11 TROUBLE SHOOTING Condition The system does not start Causes or Check Points Check that 5 minutes has passed from the time you turned the system on as the system has in built safety timers Check thermostat settings are correct Check the thermostat set point is set low enough for cooling or high enough for heating Check that the Master Controller is set to correct mode for COOL AUTO HEAT Air does not flow Indoor Unit Check if the unit is set in the correct mode COOL AUTO HEAT Check your Zone Controller is turned on If using zone sensor ensure your zone is turned on at the Master Controller During defrost cycle of the outdoor unit in HEAT mode the indoor fan will not operate Defrost cycle is indicated when HEAT is flashing on the Master Controller display OFF is displayed on my zone controller and cannot turn the zone On This means the Master Controller is turned off First turn on your air conditioner at the Master Controller You will now be able to turn on your Zone Controller For any assistance with your ESP Ultima System do not hesitate to contact our Customer Care Team for technical support on freecall number 1800 119 229 12 FREQUENTLY ASKED QUESTIONS Q I cannot adjust my set point on my Zone Controller any more than 2 higher or lower than the Master Controlle
5. ons NO DAMPER BLADE INDICATOR Room is satisfied with temperature Zone is turned off Zone is waiting on HEAT COOL mode change When in ESP AUTO damper blade indicator will automatically adjust itself to regulate the correct amount of airflow HEAT or COOL in order to maintain the desired setpoint temperature FAN ONLY MODE REPEAT de MASTER BED BEDROOM 1 BEDROOM 2 BEDROOM 3 Press the button The current fan speed setting will appear and the display backlight will turn on if it is off Press the button again to select HIGH MED LOW fan speed All open zones will circulate air throughout your home If you wish to shut any particular zone in this mode simply turn off zone by pressing the designated zone button Zone LED will go off This mode is commonly used to circulate airflow without Cooling Heating throughout your home Quite often used on mild days to circulate fresh air through the home Simply open a few windows and let the FAN ONLY MODE circulate fresh air through your home a Rene FAn ZONE till ZONE CONTROL A ES TEMP v Zone Controller FAN MODE FH f 1 will be displayed on zone control display when the Master Wall Controller is set to circulation operation During this period zone damper will be in fully open position for maximum air circulation Press the but
6. osed 4 COOL Indicator Illuminates when zone is receiving Set Temperature UP Button cooling Raises the set point for warmer temperature 5 HEAT Indicator Illuminates when zone is receiving AD Set Temperature DOWN Button heating Lowers the set point for cooler temperature 6 Temperature Set Point Display TURNING ZONE CONTROLLER ON J 2r LL Lie 3 amp TIMER ZONE COOL HEAT ESP AUTO Ve UN q REPEAT 3 ore allil max ZONE CONTROL Master Wall Controller Zone Controller Turn the system ON by pressing the button on Master Controller LM7 D or LM24W To turn the zone ON press the button on Zone Controller Alternatively press the designated zone on the Master Wall Controller Zone Controller display will show the SET TEMPERATURE ZONE and ESP AUTO Set the desired temperature by pressing either the SET TEMP UPA A or DOWN V Y arrow key For warmer room temperature press the UP arrow key For cooler room temperature press the DOWN arrow key Zone Controller temperature setting can only be adjusted 2 C below or above the Master Controller set point temperature This is a factory set limit which is recommended in order to maintain system accuracy and maximize efficiency Should this require changing contact ActronAir Technical support on freecall number 1800 119 229 Master Controller shown above is LM7 D same
7. procedure applies with LM24W model ESP AUTO MODE Indications of COOL or HEAT will show zone conditioning When zone damper is providing warm or cold air to your zone ESP AUTO OFF till MAX BEDROOM 2 BEDROOM 3 Master Wall Controller Zone Controller Press the button on until ESP AUTO appears on the display 2 Setthe desired temperature by pressing either the SET TEMP UP A A or DOWN V Y arrow key For warmer room temperature press the UP arrow key For cooler room temperature press the DOWN arrow key Turning Off 3 Press the button to turn off the zone Alternatively press the designated zone button on the Master Controller When the designated zone LED in the Master Controller turns off the zone is off n Zone Control ESP AUTO mode the controller will adjust the position of zone damper automatically in order to meet the desired temperature Heating mode will be displayed when the zone starts to heat the room Cooling mode will be displayed when the zone starts to heat the room ZONE DAMPER BLADE INDICATOR DISPLAY STATUS FULLY OPEN DAMPER BLADE Allows full airflow through in order to meet your required conditions PARTIALLY CLOSED DAMPER BLADE Regulating airflow and temperature to meet set conditions PARTIALLY OPEN DAMPER BLADE Regulating airflow and temperature to meet set conditi
8. r A 2 is the default setting for master temperature offset ActronAir recommend this 2 offset to optimise temperature control and maximize energy efficiency Moving this setting 2 will result in temperature inaccuracy Contact ActronAir technical support Tel No 1800 119 229 Q Cooling and Heating seems to take a long time to achieve temperature in ESP fan mode Am using the correct settings A ESP fan mode really comes into it s own when minimal zones are used For quicker and more responsive Cooling and Heating when using more than minimal zones select HIGH or CONT HIGH fan speed on Master Controller This will boost heating and cooling and is best optimized when you want to condition more than the minimal zone set up Q Cooling and Heating is not sufficient in my zone A Air balancing is essential part of system commissioning in ESP Ultima system The duct design may be prohibiting the correct amount of airflow reaching your area Please contact your installer to ensure air balancing has been carried out Q There is substantial air noise coming from my outlet A If the outlet gets too noisy when the unit or zone is first turned on the system maybe over supplying airflow to your area Ensure ESP fan mode is selected when minimal zones are used Q There are dashes across my control display A Make sure you have not had a power interruption If this is still present on the display after 20 seconds please
9. r fan and ActronAir ESP digital compressor technology for maximum energy savings and comfort IMPORTANT To ensure efficient and proper operation of your equipment read and understand all instructions contained in this manual and the Master Controller Manual Failure to do so may result in damage of equipment and warranty may be void CONTENTS General Information oooooocccnnnnnncccinnnnanccncnncncananccnncnnnns Page 1 Zone Controller Functions ssesssss Page 2 Turning Zone Controller On nennen Page 3 ESP Auto Mode nase Page 4 Zone Damper Blade Indicator Page 5 Fetish s Page 6 Zone Temperature Display suus Page 8 Zone Open Mode seessseeeeneen Page 10 Trouble Shooting us uocis tenter oo tero f rrr ts Page 11 Frequently Asked Questions ssssse Page 12 ZONE CONTROLLER FUNCTIONS II LL Le ESP AUTO OFF LS ZONE CONTROL 9 9 C e C29 9 9 Zone Controller 1 Mode ON OFF Button 7 Zone Indicator Turn the zone ON or Off 2 Room Temperature Button View actual room temperature ESP Auto Indicator Illuminates when zone controller is modulating the airflow 3 Damper Position Indicator Indicates the position of of zones air 9 OFF Indicator damper shown fully open damper Illuminates when zone is off and damper is fully cl
10. ton to turn off the zone damper If you do not want the unit to circulate airflow in your room in this mode simply press the button in your zone controller or turn your zone OFF at the Master Wall Controller ZONE TEMPERATURE DISPLAY TO CHECK TEMPERATURE AT MASTER WALL CONTROLLER E Hea COOL o sEET 7 REPEAT N 7 MASTER Bepl B 1 BEonoom2 S y Average Room Temperature Display A Press any of the buttons and the average room temperature will be displayed for 3 seconds INSIDE C and will be flashing The temperature displayed is the average of all activated zone sensors Checking Individual Zone Temperatures A Press any of the buttons While INSIDE C and are flashing press the zone to be checked INSIDE and C will turn off The selected zone LED and flashes During this time the selected zone temperature is displayed To check another zone simply press the zone button while the previous zone LED and are flashing Notes Room temperature displayed can be the temperature at a zone controller or ata remote sensor or the average of both depending on your installation set up ZONE TEMPERATURE DISPLAY TO CHECK TEMPERATURE AT ZONE CONTROLLER _ 2r L L Ll ZONE COOL HEAT ESP AUTO OFF P MAX ZONE CONTROL SET

Download Pdf Manuals

image

Related Search

Related Contents

Aton CL317 – Il vostro compagno affidabile    LaCinema Rugged Manual  モリワキ SUPER CUB110 `09- メガホン 注意  gebrauchsanleitung instructions for use  Hotpoint EG94 Range User Manual  DigitalFlow GF868 Service Manual 1 MB  Eglo TORENO  4724 - Safe Systems  travaux à venir - Ville de Tonnerre  

Copyright © All rights reserved.
Failed to retrieve file