FLON-01 LonWorks Adapter Module User`s Manual
Contents
1. f Mounting Into the option slot on the drive bypass Degree of protection IP20 Ambient conditions The applicable ambient conditions specified for the drive bypass in its manuals are in effect Indicators Three bicolour LEDs HOST MODULE NETWORK Connectors 20 pin connector to drive bypass X2 3 pole detachable screw terminal block X1 Technical data 140 Power supply e 3 3 V 5 max 450 mA supplied by the drive bypass General e Estimated min lifetime 100 000 h All materials UL CSA approved Complies with EMC standards EN 61000 6 4 2001 and EN 61800 3 Bus interface functionally isolated from drive bypass LONWoRKS network FLON 01 compatible devices All devices equipped with FT X1 and FTT 10A compatible transceivers Size of the network 32385 nodes divided into 127 nodes subnet with 255 subnets domain Medium Termination 105 Q 52 5 Q depending on the network topology See Bus termination on page 22 Cable specifications See the following tables Technical data 141 LONWORKs network cable specifications Control General Data grade JY St Y signalling purpose level 4 2x2x0 8 grade grade 22 AWG 20 4 AWG 16 AWG 16AWG 0 65 mm 0 8 mm 1 3 mm 1 3 mm Max DC resistance 55 om 28 2 okm 118 Q km 74 0 Q km at 20 C loop Max DC resistance 5 unbalance Max mu
2. Default value No override state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables nviDigCmd1 nviDigCmd12 Definition Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne work inpu work inpu work inpu work inpu work inpu work inpu work inpu work inpu work inpu work inpu work inpu work inpu Explanation SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi SNVT_swi ch nviDigCmd1 ch nviDigCmd2 ch nviDigCmd3 ch nviDigCmd4 ch nviDigCmd5 ch nviDigCmd6 ch nviDigCmd7 ch nviDigCmd8 ch nviDigCmd9 ch nviDigCmd10 ch nviDigCmd11 ch nviDigCmd12 43 Each variable supplies a digital command 1 12 to the host Configuration and mapping of these points is host specific Valid range State Value Digital command 0 0 Inactive 1 100 Active Default value Inactive state 0 value 0 Network variables 44 nviDrvProcStpt Definition Network input SNVT_switch nviDrvProcStpt Explanation Provides start stop control and a low resolution process setpoint lt is active when external control location EXT2 is selected Valid range State Value Command 0 Not used Stop 1 0 0 1 1 to 200 0 5 to 100 0 1 201 to 255 100 OxFF Not used AUTO Invalid
3. ooocooococrororommmmoooo 25 COI e statii ttle retary Sed atte oe tle Reset SN tata 25 Drive bypass configuration 0 0 0 0 25 Control locations dera li daa 2 Be 30 Communication ARGANDA A A 31 OVENVIEW ss errar or aa dee Ata 31 General rere ome EEES ARA Lee RADA A EAN 31 LonMarkD ObjEctS lt nirre erai aids ak rte acc il 32 Node Object A NO 32 Variable speed motor drive object u un anaana 33 Open loop actuator object DigitalCommand oooococoooo o 35 Open loop sensor object DigitalStatuS oooooooooooo oo 35 Open loop sensor object Digitallnput oooocococooo oo 36 Open loop sensor object DigitalOutput oocococccccco o 36 Open loop actuator object AnalogCmd occcccccccc 36 Open loop sensor object AnalogStatus o ooooccococcccoc oo 37 RESCUE TINS lt A tee yo eye bate eae ae ets 38 Network variables 00 0 cece ence eee e een eens 39 Supported input network variables 00 00 cee eee ee ee 39 nviAnlgCmd1 nviAnilgCmd8 02 eee 41 ee AAA A EE pane NA 42 nviDigCmd1 nviDigOmd12 0 ee 43 NAVIDIVPrOCSipl catia ho aoe de hae ee hae eka geld 44 nviDrvSpeedScale ici cara lata 45 nviDIVSPECdS tp iia ato ato eite nieces 46 nviEMPOOVErTIdS cia A ee 47 PERU REZ CU Gs aco ee ey rd ot bles weer NOG rd ie aa 48 a A eke a a E E debate eTa O aestt 48 nviREGUEST A a a E EE S 49 nViResetFa lt oras cara AA da eee ells
4. Explanation Provides the speed of the drive as a percentage of the nominal speed Valid range Value Speed 32768 163 84 32766 163 83 Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 77 nvoDrvTemp Definition Network output SNVT_temp_p nvoDrvTemp Explanation Drive temperature in degrees C Valid range Value Temperature 27317 273 17 C 0 0 C 32767 327 67 C When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 78 nvoDrvTorque Definition Network output SNVT_lev_percent nvoDrvTorque Explanation Output torque as a percentage of motor nominal torque Valid range Value Torque
5. When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 62 nvoBypKwh_R Definition Network output SNVT_elec_kwh_I nvoBypKwh_R Explanation Value of the resettable bypass kWh counter Valid range Value Energy 2147483648 214748364 8 kWh 2147483646 214748364 6 kWh Ox7FFFFFFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables nvoBypRunHours Definition 63 Network output SNVT_time_hour nvoBypRunHours Explanation Total operation time for the motor by the bypass in running hours Valid range Value Time 0 0 0h 65534 65534 h 65535 Invalid When transmitted This value is transmitted immediately when its va
6. Default value AUTO state OxFF This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables nviDrvSpeedScale Definition 45 Network input SNVT_lev_percent nviDrvSpeedScale Explanation Provides scaling for nviDrvSpeedStpt For example if nviDrvSpeedStpt value is 100 and nviDrvSpeedScale value is 150 then the actual speed setpoint value is 150 meaning 1 5 times the nominal speed in reverse direction Valid range Value Speed scaling 32768 163 840 32766 163 830 Ox7FFF Invalid Default value Defined by SCPTdefScale nciDrvSpeedScale This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables 46 nviDrvSpeedStpt Definition Network input SNVT_switch nviDrvSpeedStpt Explanation Provides start stop control and a low resolution speed setpoint for external control location EXT1 The speed setpoint is the result of multiplication of nviDrvSpeedStpt and nviDrvSpeedScale For example if the value of nviDrvSpeedStpt is 100 and the value of nviDrvSpeedScale is 150 the actual speed setpoint value is 150 meaning 1 5 times nominal speed in reverse direction Valid range State Value Equivalent Requested percentage speed 0 Not used Not used STOPPED 1 0 0 0 1 1 to 100 1 to
7. a DigitalCommand nviDigCmd1 12 Manufacturer defined SNVT_switch network variables Manufacturer defined configuration properties nc48 nciDigRevHrtBt E Open loop sensor object DigitalStatus DigitalStatus Manufacturer defined nvoDigSts1 12 network variables SNVT_switch Manufacturer defined configuration properties nc49 nciDigSndHrtBt nc52 nciDigMinOutTm A Communication 36 Open loop sensor object Digitallnput Digitallnput my Manufacturer defined 4 nvoDigimputt 12 network variables SNVT_switch Manufacturer defined configuration properties nc49 nciDigSndHrtBt nc52 nciDigMinOutTm Open loop sensor object DigitalOutput DigitalOutput Manufacturer defined 1 nvoDigOutputi 12 network variables SNVT_switch Manufacturer defined configuration properties nc49 nciDigSndHrtBt nc52 nciDigMinOutTm Open loop actuator object AnalogCmd AnalogCmd 1 nviAnlgCmd1 8 Manufacturer defined SNVT_lev_percent network variables Manufacturer defined configuration properties nc48 nciAnigRevHrtBt Communication 37 Open loop sensor object AnalogStatus AnalogStatus N Manufacturer defined 1 nvoAnIgSts1 8 network variables SNVT_lev_percent Manufacturer defined configuration properties nc49 nc
8. Default value Read from host on power on refresh Network variables 128 UCPTpid1DerTime nciPid1DerTime UCPTpid2DerTime nciPid2DerTime Definition Network config input SNVT_time_sec nciPid1DerTime Network config input SNVT_time_sec nciPid2DerTime Explanation PID controller derivation times in seconds Valid range Value Derivation time 0 Os 1 0 1s 65535 6553 5 s 65537 Invalid Default value Read from host on power on refresh Network variables 129 UCPTpid1Gain nciPid1Gain UCPTpid2Gain nciPid2Gain Definition Network config input SNVT_lev_percent nciPid1Gain Network config input SNVT_lev_percent nciPid2Gain Explanation PID controller gain values Valid Range Value Gain 32768 163 84 32766 163 83 32767 Invalid Default Value Read from the host on power on refresh Network variables 130 UCPTpid1IntTime nciPid1IntTime UCPTpid2IntTime nciPid2IntTime Definition Network config input SNVT_time_sec nciPid1IntTime Network config input SNVT_time_sec nciPid2IntTime Explanation PID controller integration times in seconds Valid range Value Time 0 Os 1 0 1s 65535 6553 5 s 65537 Invalid Default value Read from host on power on refresh Network variables UCPTstopLevel nciStopLevel Definition 131 Network config input SNVT_lev_percent nciStopLe
9. Defines the minimum wait time before the network output variables can be propagated resent Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 5s Network variables 120 SCPTminSetpoint nciMinSpeed Definition Network config input SNVT_lev_percent nciMinSpeed Explanation Defines the minimum speed of the motor as a percentage of the nominal speed defined by the Nominal Speed SCPTnomRPM nciNmlSpeed configuration value The value of the minimum speed must be defined so that 163 840 lt minimum speed lt maximum speed lt 163 830 Valid range Value Maximum speed 32768 163 840 32766 163 830 32767 Invalid Default value Read from host on power up Network variables SCPTnomFreq nciNmiFreq Definition Network config input SNVT_freq_hz nciNmlFreq Explanation 121 Provides the nominal frequency of the motor in Hz Valid range Value Nominal frequency 0 0 Hz 100 100 Hz Default value Read from host on power up refresh Network variables 122 SCPTnomRPM nciNmiSpeed Definition Network config input SNVT_rpm nciNmlSpeed Explanation Provides the nominal motor speed in rpm This value is necessary to determine the minimum and maximum speed for the motor based on the configuration properties SCPTminSetpoint nciMinSpeed and SCPTm
10. nv Network variable nvi Input network variable nvo Output network variable Object Object is a set of one or more network variables implemented as SNVTs with semantic definitions relating the behaviour of the object to the network variable values in addition to a set of configuration properties For example the Variable Speed Motor Drive Object and the Node Object represent two types of objects Parameter A parameter is an operating instruction for the drive bypass Parameters can be read and programmed by using the drive control panel or through the FLON 01 module Service Pin The Service Pin is used in installing the node Pressing the Service Pin causes the LONWoRKS node to send the so called Service Pin Message which includes among other things the Neuron ID This informs the network or installation tool about the Definitions and abbreviations 137 node Holding the Service Pin for more than 10 seconds forces the module to Go Unconfigured SNVT Standard Network Variable Type UCPT User Configuration Property Type Definitions and abbreviations 138 Definitions and abbreviations 139 Technical data FLON 01 Enclosure O FLON 01 LONWORKS ADAPTER UYUYYGY HH NETWORK X e pa QUL
11. nviStartEnable2 Definition Network input SNVT_switch nviStartEnable2 Explanation Sets start enable 2 for the host Valid range State Value Command 0 0 Start 2 disabled 1 100 Start 2 enabled Default value Start 2 disabled state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables Supported output network variables 53 Name Description More info on page nvoAccelerating Indicates the drive is accelerating 56 nvoAlarm Indicates the drive has an alarm Dr nvoAnlginput Status of analog inputs 1 to 8 58 nvoAnlginput8 nvoAnlgOutput Status of analog outputs 1 to 8 59 nvoAnlgOutput8 nvoAnlgSts1 Analog statuses 1 to 8 from the host 60 nvoAnlgSts8 nvoAtReference Indicates the drive is at reference 61 nvoBypKwh_R Value of the resettable bypass kWh counter 62 nvoBypRunHours Operation time for the motor by the bypass in 63 whole hours nvoBypTemp Bypass PCB temperature in degrees C 64 nvoCtlOverrideSt Indicates that the LonWorks network has 65 overridden other control and reference sources nvoDecelerating Indicates the drive is decelerating 66 nvoDigInput1 Status of digital inputs 1 to 8 67 nvoDigInput12 nvoDigOutput1 Status of digital outputs 1 to 8 68 nvoDigOutput12 nvoDigSts1 Digital statuses 1 t
12. 163 84 32766 163 83 32767 Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 98 nvoPid1Fbk nvoPid2Fbk Definition Network output SNVT_lev_percent nvoPid1Fbk Network output SNVT_lev_percent nvoPid2Fbk Explanation PID controller feedback values Valid range Value Feedback 32768 163 84 32766 163 83 32767 Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 99 nvoReady Definition Network output SNVT_switch nvoReady Explanation Indicates the drive is ready to receive a start command Valid range State Value Status 0 0 0 Not ready 1 100 0 Ready When
13. 23 Earthing the LoNWoRks cable screens The LONWORKS cable screen can be directly earthed at one station only At other stations the screen should be earthed via an RC filter FLON 01 FLON 01 FLON 01 X1 X1 X1 NY LN jg 13N gt GIHS anal J ul J tk iI GIHS eral tk il CHS NV LIN Ja 13N Nv LN jg 13N 1050 To A ATA A E eee L 1050 Figure 3 Network cable connection for bus topology Electrical installation 24 Electrical installation 25 Drive bypass configuration Overview This chapter gives information on configuring the drive or bypass for communication through the FLON 01 LONWoRrks Adapter module Note The FLON 01 cannot control the drive bypass before it is configured for the LONWorks network The LONWorKs communication configuration does not require parametrisation of the drive bypass The LONWOoRks network is configured using a network installation tool Please refer to the installation tool documentation for network configuration and to chapter Communication for the resource files Drive bypass configuration It is preferable to configure the drive bypass before the FLON 01 is configured for the network The reason for this is that the FLON 01 reads several parameter values from the drive bypass
14. terminated distance free topology i Total wire 500m 500m 500m 500m length Technical data 143 Topology Supports free topology wiring and will accommodate bus star loop or any combination of these topologies Serial communication type Asynchronous half duplex Transfer rate 78 kbit s Protocol LonTalke Documents LONMARK Layers 1 6 Interoperability Guidelines version 3 3 Technical data 144 Technical data EFFECTIVE 01 12 2008 Zz WwW lt gt Lu a Mm o Tt o o o o D 2 oo PADD S ABB Oy ABB Inc ABB Beijing Drive AC Drives Automation Technologies Systems Co Ltd P O Box 184 Drives amp Motors No 1 Block D FIN 00381 HELSINKI 16250 West Glendale Drive A 10 Jiuxiangiao Beilu FINLAND New Berlin WI 53151 Chaoyang District Telephone 358 10 22 11 USA Beijing P R CHINA 100015 Fax 358 10 22 22681 Telephone 262 785 3200 Telephone 86 10 5821 7788 Internet www abb com 800 HELP 365 Fax 86 10 5821 7618 Fax 262 780 5135
15. FLON_V44 XIF The device interface XIF file is a standalone file that documents the device interface for a type of device It also documents the default values for all the configuration properties on the device The different XIF files are for the different versions of the LonMaker tool The appropriate XIF file version is chosen depending on the installation tool used Communication Network variables 39 Supported input network variables The actual valid range of a network input variable can be smaller than the one reported in this manual depending of the drive firmware Typically the ACx550 bypass discards the parameter changes if the value coming from the fieldbus is outside the range of the drive parameter Name Description More info on page nviAnlgCmd1 Supply of analog commands to the host 41 nviAnlgCmd8 nviCtlOverrideCm Request for override of control and references 42 sources by the network nviDigCmd7 Control of state of digital outputs 1 to 12 43 nviDigCmd12 nviDrvProcStpt Low resolution process setpoint 44 nviDrvSpeedScale Scaling for nviDrvSpeedStpt 45 nviDrvSpeedStpt Low resolution speed setpoint 46 nviEmrgOverride Possibility to stop the motor in case of an 47 emergency nviExt1Ext2Ctrl Sets the control location that should be used 48 EXT1 EXT2 nviLocLock Sets local lock on or off 48 nviRequest Enables control commands and updates from 49
16. State Value Command 0 0 Local lock is off 1 100 Local lock is on Default value Local lock off state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables nviRequest Definition 49 Network input SNVT_obj_request nviRequest Explanation Enables control commands and updates from network The status of the node is reported in nvoStatus Valid range Object request Function RQ_UPDATE_STATUS Updates nvoStatus RQ_CLEAR_STATUS Clears nvoStatus RQ_CLEAR_ALARM Resets fault in the drive bypass RQ_REPORT_MASK Reports supported requests in nvoStatus RQ_NORMAL Sets object to default state the normal request RQ_DISABLE Stops the drive bypass with the selected stop mode and disables the operation and object RQ_ENABLE Enables the drive for operation and enables the object Commands not listed above will be reported as invalid_request in nvoStatus Network variables 50 nviResetFault Definition Network input SNVT_switch nviResetFault Explanation Clears the fault status in the host Valid range State Value Command 0 0 Enable reset fault 1 100 Reset fault On a transition from 0 to 1 this input network variable clears the fault condition in the drive Following a fault reset this va
17. 32768 163 84 32766 163 83 Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 79 nvoDrvVolt Definition Network output SNVT_volt nvoDrvVolt Explanation Motor output voltage Valid range Value Voltage 0 0 0V 3276 6 3276 6 V Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 80 nvoEmrgOvrdStat Definition Network output SNVT_hvac_emerg nvoEmrgOvrdStat Explanation Feedback for the nviEmrgOverride Valid range Value Function EMERG_NORMAL No emergency mode motor control enabled EMERG_SHUTDOWN Emergency shutdown mode Stops motor EMERG_NUL Invalid
18. ID 2 5 byte 6 of the domain ID MSB DOMAIN ID 2 4 byte 5 of the domain ID DOMAIN ID 2 3 byte 4 of the domain ID DOMAIN ID 2 2 byte 3 of the domain ID DOMAIN ID 2 1 byte 2 of the domain ID DOMAIN ID 2 0 byte 1 of the domain ID LSB XMIT ERRORS Explanation Indicates the number of CRC errors detected during packet reception An increasing value may be due to collisions or noise on the transceiver input TRANS TIMEOUTS Explanation Indicates the number of times that the node failed to receive expected acknowledgements or responses after retrying configuring number of times An increasing value may be due to destination nodes being inaccessible on the network transmission Drive bypass configuration 30 failures because of noise on the channel or if any destination node has insufficient buffers or receive transaction records Control locations ABB drives and bypasses can receive control information from multiple sources including digital inputs analogue inputs the drive control panel and a communication module e g FLON 01 ABB drives and bypasses allow the user to separately determine the source for each type of control information Start Stop Direction Reference Fault Reset etc In order to give the fieldbus master station the most complete control over the drive bypass the communication module must be selected as source for this information See the user documentation of the drive bypass
19. before the communication through the adapter module can be started Introduction 14 Communication contains a description of how data is transmitted through the FLON 01 module Network variables presents the network variable list of the FLON 01 Diagnostics explains how to trace faults with the status LEDs on the FLON 01 module Definitions and abbreviations Technical data contains information on physical dimensions configurable settings and connectors of the module and the specification of the fieldbus link Further information Further information is available on the Internet from www lonmark org and www echelon com Introduction 15 Overview Overview This chapter contains a short description of the LoNWorKs system and the FLON 01 Adapter module and a delivery checklist The LonWorks system The LoNWorks system is an open serial communication solution that enables data exchange between all kinds of automation components A LONWorks network consists of intelligent devices called nodes connected by one or more communications media that communicate with one another using the LonTalk protocol A LoNWorks network can consist of up to 32385 nodes divided into 255 subnets 127 nodes subnet Nodes are programmed to send messages to one another in response to external events or messages they receive Each intelligent device for example a programmable thermostat in a building control system is
20. specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 85 nvoForward Definition Network output SNVT_switch nvoForward Explanation Indicates the drive is running in the forward direction Valid range State Value Status 0 0 0 Not forward 1 100 0 Forward When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 86 nvoFreqAct Definition Network output SNVT_freq_hz nvoFreqAct Explanation Output frequency in Hz Valid range Value Frequency 0 0 0 Hz 65535 6553 5 Hz When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nc
21. will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 102 nvoSpeedActRpm Definition Network output SNVT_count_inc nvoSpeedActRpm Explanation Output speed in rpm Valid range Value Speed 32768 32767 rpm 32767 32767 rpm When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 103 nvoStarted Definition Network output SNVT_switch nvoStarted Explanation Indicates the drive has received a start command Valid range State Value Status 0 0 0 Not started 1 100 0 Started When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update
22. 100 0 1 to 100 0 OxFF Not used Not used AUTO invalid Default value The default value is AUTO state OxFF The value will be adapted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables nviEmrgOverride Definition 47 Network input SNVT_hvac_emerg nviEmrgOverride HVAC Emergency Mode Explanation Provides the possibility to stop the motor in case of an emergency Valid range Setting Function EMERG_NORMAL No emergency mode motor control enabled EMERG_PRESSURIZE See EMERG_NORMAL EMERG_DEPRESSURIZE See EMERG_NORMAL EMERG_PURGE See EMERG_NORMAL EMERG_SHUTDOWN Emergency shutdown mode Stops motor EMERG_FIRE See EMERG_NORMAL EMERG_NULL See EMERG_NORMAL Default value The default value is EMERG_ NORMAL The value will be adapted at power up and in case of not receiving an update within the specified Receive Heartbeat ime Network variables 48 nviExt1Ext2Ctrl Definition Network input SNVT_switch nviExt1Ext2Ctrl Explanation Sets the external control location EXT1 EXT2 Valid range State Value Control location 0 0 EXT1 1 100 EXT2 Default value EXT1 state 0 value 0 nviLocLock Definition Network input SNVT_switch nviLocLock Explanation Sets local lock on or off Valid range
23. 50 AMRUNENADIS 2303 RDA AA AAA ARA AAA AA 51 PASIVO PAS co aaa elas 51 AUSTEN A pe TA 52 Table of contents nviStartEnable2 hi aii on ati dirt late As 52 Supported output network variables oooococococcococooo o 53 nvoAccelerating isr acasan cece ee tees 56 AVOAIARM DnS hanao gees Eos eet Gustin a ane ii jo dace a E UN aden tag 57 nvoAnlginput1 nvoAniginput8 0 eee 58 nvoAnlgOutput1 nvoAnIgOutput8 2 0 eee eee 59 nvoAnlgSts1 nvoAnIgSts8 1 1 2 2 0c eee 60 nvoAtReference 0 cece ete eet eee 61 NVOBYPKWAR feito Care tees ts kate aa ae eee a Rie ee 62 nvoBypRUNHQUES ui airada repita ella ina p E a a a aE a 63 AVOBYPTEMP tiens la taa 64 nvoCtlOverrideSt e sarae e a a eee 65 nvoDecelerating cacravusthin he tere cren rd 66 nvoDigInput1 nvoDiglnput12 0 0 eee 67 nvoDigOutput1 nvoDigOutput12 2 2 eee 68 nvoDigSts1 nvoDigSts12 20 0 eee 69 NVODIVCUI dato ra a ade a Decre 70 NVODIVDEBUS 20 is ina a 71 NVODMVKWHUNR uds a die eee ova ae 72 NVODIVKWH IR ooo at ag eaten ti ae aad eee SR ad 73 NVODEVR WE vite Sada ets aa 74 NVODMVRUNHOUS caian tt at 75 nvoDivSpeed recicla oe IA aed 76 NVODEVTSMP Aoi aa Ea Sn i aa a aa a n EE 77 NVODIV TOQUE eiii ias at nea aan tn aay a aa a ahaaa ea 78 NVODIWV lt aa A aa vl tens 79 nvoEmrgOvrdStat oia e eke DUES 80 NVOENMADIEd ac e a id A el Bek o a de E 81 nvoE Xt EX Slate 82 NvoRaullCOdE ip sins al
24. ABB Drives User s Manual LonWorks Adapter Module FLON 01 FLON 01 manent seat eeteeee Witenes LL LLL LUTO 191 z M AA EDER PADDED LonWorks Adapter Module FLON 01 User s Manual 3AUA0000041017 REV AEN EFFECTIVE 01 12 2008 2008 ABB Oy All Rights Reserved Safety instructions Overview This chapter states the general safety instructions that must be followed when installing and operating the FLON 01 LonWorks Adapter module The material in this chapter must be studied before attempting any work on or with the unit In addition to the safety instructions given below read the complete safety instructions of the specific drive you are working on General safety instructions A WARNING All electrical installation and maintenance work on the drive should be carried out by qualified electricians The drive and adjoining equipment must be properly earthed Do not attempt any work on a powered drive After switching off the mains always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter the motor or the motor cable It is good practice to check with a voltage indicating instrument that the drive is in fact discharged before beginning work The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied regardless of motor operation There can be dangerous voltages inside the drive f
25. CPTparWritelndex nciParWritelndex UCPTparWritelndex Defines the parameter value to be written to 126 nciParWritelndex the drive UCPTpid1DerFiltTim PID controller derivation filter times in 127 e nciPid1DerFiltTi seconds UCPTpid2DerFiltTim e nciPid2DerFiltTi UCPTpid1DerTime PID controller derivation times in seconds 128 nciPid1DerTime UCPTpid2DerTime nciPid2DerTime UCPTpid1Gain PID controller gain values in percent 129 nciPid1Gain UCPTpid2Gain nciPid2Gain UCPTpid1IntTime PID controller integration times in seconds 130 nciPid1IntTime UCPTpid2IntTime nciPid2IntTime UCPTstopLevel Stop level value in ramp stop mode 131 nciStopLevel UCPTstopMode Selects between coast and ramp stop 132 nciStopMode Network variables 109 SCPTdefScale nciDrvSpeedScale Definition Network input config SNVT_lev_percent nciDrvSpeedScale Explanation Default value for nviDrvSpeedScale Valid range Value Speed scaling 32768 163 840 32766 163 830 32767 Invalid Default value 100 SCPTlocation nciLocation Definition Network input config SNVT_str_asc nciLocation Explanation Location Label used to provide more descriptive physical location information than can be provided by the Neuron Chip s 6 byte location string Valid range Any NULL terminated ASCII string of 31 characters Default value Empty spaces Network variable
26. G Before installation switch off the drive bypass power A supply Wait five minutes to ensure that the capacitor bank of the drive bypass is discharged Switch off all dangerous voltages connected from external control circuits to the inputs and outputs of the drive bypass General cabling instructions Arrange the bus cables as far away from the motor cables as possible Avoid parallel runs Use bushings at cable entries Electrical installation 22 Network connection The bus cable is connected to terminal block X1 on the FLON 01 x1 Description 1 SHLD RC filtered connection to the module ground 2 NETA Network Connection A 3 NETB Network Connection B For the LONWorKS TP FT 10 topology either network connection may be connected to either pin Bus termination The bus line is terminated with resistors connected between the network cable conductors A and B when the FLON 01 module is at the end of the bus Termination prevents signal reflections from the bus cable ends ae NO NO NO NO NO T2 NO NO T2 NO NO T1 NO a Star topology b Bus topology c Ring topology T1 52 5 ohm termination at one of the nodes in one bus segment T2 105 ohm termination at both ends of the line NO No termination Figure 2 Bus termination for different network topologies Electrical installation
27. LON 01 supports TP FT 10 media A LONWorKS router would be required for the FLON 01 to interoperate with devices on other media Overview 18 Delivery check The option package for the FLON 01 LonWorks Adapter module contains LonWorks Adapter module type FLON 01 e this manual Overview 19 Mechanical installation Mounting WARNING Follow the safety instructions given in this manual and the drive documentation The FLON 01 is to be inserted into its specific position on the drive or bypass The module is held in place with plastic pins and one screw The screw also provides the earthing of the fieldbus cable shield connected to the module On installation of the module the signal and power connection to the drive bypass is made through a 20 pin connector The connector on the controlled equipment may have fewer pins as not all available signals are necessarily used Mounting procedure Insert the module carefully into its position on the drive bypass e Fasten the screw Note Correct installation of the screw is essential for fulfilling the EMC requirements and for proper operation of the module Mechanical installation 20 Mechanical installation 21 Electrical installation Overview This chapter contains general cabling instructions e instructions for bus termination instructions for connecting the module to the LONWorks network WARNIN
28. PTminSendTime nciAnigMinOutTm 000 0c eee eee 117 SCPTminSendTime nciDigMinOutTm 0 000 eee eee 118 SCPTminSendTime nciVsmdMinOutTm 2 0 0200 119 SCPTminSetpoint nciMinSpeed 0 0 e eee ee 120 SCPTnomFreq nciNmIiFreq oooccccccccc eee 121 SCPTnomRPM nciNmlSpeed 0 0c eee ee eee 122 SCPTrampDownTm nciRampDownTm 0 20 ee eee eee 123 SCPTrampUpTm nciRampUpTm 20 0 eee eee ee 123 UCPTbypRunDelay nciBypRunDelay 0 00 eee 124 UCPTdrvCurntLimit nciDrvCurntLimit 0 0 0 0 000 124 UCPTparReadIndex nciParReadIndex 0 0 0 0 ee ee eee 125 UCPTparValue nciParWriteValue oooooccccococcccoo o 125 UCPTparWritelndex nciParWritelndex oooocococoo oooo 126 UCPTpid1DerFiltTime nciPid1DerFiltTi Table of contents UCPTpid2DerFiltTime nciPid2DerFiltTi 127 UCPTpid1DerTime nciPid1DerTime UCPTpid2DerTime nciPid2DerTime 0 0 000 eee ee 128 UCPTpid1Gain nciPid1Gain UCPTpid2Gain nciPid2Gain 129 UCPTpid1IntTime nciPid1IntTime UCPTpid2IntTime nciPid2IntTime 20 0 130 UCPTstopLevel nciStopLevel 0 0c eee eee eee 131 UCPTstopMode nciStopMode 20 cece eee eee 132 Diagnosti si 262 dras ineen assan AAN A 133 LED UINGICAIONS ata tele Deans see ah to SO et ah tates od 133 Definitio
29. When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 81 nvoEnabled Definition Network output SNVT_switch nvoEnabled Explanation Indicates the drive has received the run enable command Valid range State Value Status 0 0 0 Not enabled 1 100 0 Enabled When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 82 nvoExt1Ext2Stat Definition Network output SNVT_switch nvoExt1Ext2Stat Explanation This output variable shows the external control location currently used EXT1 or EXT2 Valid range State Value Control location 0 0 EXT1 1 100 EXT2 When transmitted This value is transmitted immediately when its val
30. a LonWorks node A node is connected to other nodes with appropriate communications media such as twisted pair cable RF link or power line circuit Each node includes a physical interface transceiver that interfaces with the communication media The FLON 01 module uses the FT X1 Free Topology Transceiver compatible with FTT 10A transceiver from Echelon Corporation This is the most commonly used twisted pair media in building automation and this architecture supports star bus and loop wiring The FT X1 transceiver connects to a twisted pair cable with a baud rate of 78 kbit s and appears as a high impedance to the network when unpowered hence it does not interfere with the network communications when powered down Overview 16 LONWORKs nodes are objects that respond to various inputs and that produce desired outputs Connecting the inputs and outputs of these network objects enables the network to perform specific tasks While the function of any particular node may be quite simple the interaction among nodes enables a LoNWorks network to perform complex tasks A benefit of LONWorKS networks is that a small number of common node types may perform a broad spectrum of different functions depending on how they are configured and connected The FLON 01 LonWorks Adapter module The FLON 01 LonWorks Adapter module is an optional device which enables the connection of an ABB drive or E Clipse Bypass to a LONWorks netw
31. a Na 83 NVORaulted toa idas diene r aa fed ee Ladino eke 84 NVOF OWT iia ina lua al aia lege 85 NVORTE A Cinta aid ida A 86 NVOLIMI yaris AS oe iO tated HERO Se 87 nvoLineUVVolt nvoLineVWVolt nvoLineWUVolt 88 MNVOLINEVOlt cosita tacon ri ie Aaa ls 89 NvOLOCREMSTAL iio cts di Ae 90 NVOMIREVONIM ala 91 Table of contents 10 AVOMIPTOMADE orita e na 92 NVON 0 IE eee sR A ADORA AAA ee Beas 93 PUONSIRSIL 12 coca as AA e 94 PAINT OT ad a n gah dea ica rl dec Bid wight 95 A E eee OWS 96 nvoPid1Dev nvoPid2Dev 0 0 eee 97 nvoPid1Fbk nvoPid2Fbk 0 0 0 c eee eee ee 98 NVORGAY na tarada ais 99 NVOR VOTSE e ae ERA A AA oom OA 100 AVORUMMING tacna da 101 nvoSpeedActRpM ccoo 102 AUS LI NAAA oe eae 103 ANOTA E le E 104 nvoZeroSp peed cui ee ee Aa dad eke ed 105 Supported network configuration properties oooooocooooo 106 SCPTdefScale nciDrvSpeedScale 0000 cee eee eee 109 SCPTlocation nciLocation ok wns eo anc eee whe poe EES 109 SCPTmaxRcvTime nciAnlgRevHrtBt 2 0020 eee eee ee 110 SCPTmaxRcvTime nciDigRcvHrtBt 0 2 eee eee 111 SCPTmaxRevTime nciVsmdRevHrtBt 0 0000000000 112 SCPTmaxSendTime nciAnlgSndHrtBt 0002s 113 SCPTmaxSendTime nciDigSndHrtBt 2020 00 eee 114 SCPTmaxSendTime nciVsmdSndHrtBt 2 00000 115 SCPTmaxSetpoint nciMaxSpeed 000 cee eee ee 116 SC
32. alid Default Value Read from host on power on refresh Network variables 125 UCPTparReadIndex nciParReadindex Definition Network config input SNVT_count nciParReadIndex Explanation Contains the parameter to read for nvoParReadValue Valid range Value Parameter value 0 65535 Parameter dependent Default value 0 UCPTparValue nciParWriteValue Definition Network config input SNVT_count_inc nciParWriteValue Explanation Contains the value to be written to the parameter set by UCPTparWritelndex nciParWritelndex Valid range Value Parameter value 0 65534 Parameter dependent OxFFFF Invalid Default value 0 Network variables 126 UCPTparWritelndex nciParWritelndex Definition Network config input SNVT_count nciParWritelndex Explanation Contains the parameter to write for UCPTparValue nciParWrite Value Valid range Value Parameter value 0 65535 Parameter dependent Default value 0 Network variables UCPTpid1DerFiltTime nciPid1DerFiltTi UCPTpid2DerFiltTime nciPid2DerFiltTi Definition 127 Network config input SNVT_time_sec nciPid1DerFiltTi Network config input SNVT_time_sec nciPid2DerFiltTi Explanation PID controller derivation filter times in seconds Valid range Value Filter time 0 Os 1 0 1s 65535 6553 5 s 65537 Invalid
33. ange State Value Reference Source 0 0 0 Other 1 100 0 Network When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 96 nvoParReadValue Definition Network output SNVT_count nvoParReadValue Explanation Contains the value read from parameter set by UCPTparReadIndex nciParReadIndex Valid range Value Parameter value 0 65534 Parameter dependent OxFFFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 97 nvoPid1Dev nvoPid2Dev Definition Network output SNVT_lev_percent nvoPID1Dev Network output SNVT_lev_percent nvoPID2Dev Explanation PID controller deviation values Valid range Value Feedback 32768
34. ated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 72 nvoDrvKwh_NR Definition Network output SNVT_elec_kwh_ nvoDrvKwh_NR Explanation Value of the non resettable drive kWh counter Valid range Value Energy 2147483648 214748364 8 kWh 2147483646 214748364 6 kWh Ox7FFFFFFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 73 nvoDrvKwh_R Definition Network output SNVT_elec_kwh_I nvoDrvKwh_R Explanation Value of the resettable drive kWh counter Valid range Value Energy 2147483648 214748364 8 kWh 2147483646 214748364 6 kWh Ox7FFFFFFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm confi
35. ation properties that are defined in order to realize functions only applicable for ABB drives bypasses The network variables and configuration properties included by the node drive and open loop sensor actuator objects are detailed in chapter Network variables Node object Node Object S 1 nviRequest SNVT_obj_request Mandatory network variables nvoStatus SNVT_obj_status Configuration properties nc17 nciLocation Communication Variable speed motor drive object 33 a Variable Speed Motor Drive 6010 q4 nviDrvSpeedStpt Mandatory 4 nvoDrvSpeed SNVT_switch network variables SNVT_lev_percent 3 nvoDrvCurnt SNVT_amp Optional nvoDrvVolt 2 nviDrvSpeedScale 5 SNVT volt SNVT_lev_percent network o nvoDrvPwr variables SNVT_power_kilo 7 nvoDrvRunHours SNVT_time_hour Configuration properties nc158 nciNmiSpeed mandatory nc48 nciVsmdRevHrtBt nc159 nciNmiFreq mandatory nc49 nciVsmdSndHrtBt mandatory nc160 nciRampUpTm mandatory nc50 nciMaxSpeed mandatory nc161 nciRampDownTm mandatory nc52 nciVsmdMinOutTm nc162 nciDrvSpeedScale nc53 nciMinSpeed mandatory 100 nviCtiOverrideCm 200 nvoAtReference SNVT_switch SNVT_switch 101 nviDrvProcSipt Manufacturer 201 nvoAccel
36. axSetpoint nciMaxSpeed Valid range Value Nominal speed 0 0 rpm 65534 65534 rpm 65535 Invalid Default value Read from host on power up refresh Network variables 123 SCPTrampDownTm nciRampDownTm Definition Network config input SNVT_time_sec nciRampDownTm Explanation Provides the ramp down time of the motor Valid range Value Ramp down time 0 0 0 s 65534 6553 4 s 65535 Invalid Default value Read from host on power up refresh SCPTrampUpTm nciRampUpTm Definition Network config input SNVT_time_sec nciRampUpTm Explanation Provides the ramp up time of the motor Valid range Value Ramp up time 0 0 0s 65534 6553 4 s 65535 Invalid Default value Read from host on power up refresh Network variables 124 UCPTbypRunDelay nciBypRunDelay Definition Network input config SNVT_time_sec nciBypRunDelay Explanation Sets the additional pick up delay for bypass contactor Valid Range Value Pick up delay 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default Value Read from host on power up refresh UCPTdrvCurntLimit nciDrvCurntLimit Definition Network input config SNVT_amp nciDrvCurntLimit Explanation Sets the drive output current limit in amperes Valid Range Value Current limit 0 0 0A 32766 3276 6 A Ox7FFF Inv
37. cted as the active control source Valid range State Value Control source 0 0 0 Other 1 100 0 Network When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 94 nvoNetRef1 Definition Network output SNVT_switch nvoNetRef1 Explanation Indicates the LoNWorks network is selected as the active reference REF1 source Valid range State Value Reference Source 0 0 0 Other 1 100 0 Network When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 95 nvoNetRef2 Definition Network output SNVT_switch nvoNetRef2 Explanation Indicates the LONWORks network is selected as the active reference REF2 source Valid r
38. dTime Defines the minimum wait time before 117 nciAnlgMinOutTm network output variables nvoAnigSts7 nvoAnlgSts8 nvoAnlginput nvoAnlginput8 nvoAnlgOutput nvoAnlgOutput8 can be propagated resent SCPTminSendTime Defines the minimum wait time before 118 nciDigMinOutTm network output variables nvoDigSts7 nvoDigSts12 nvoDiginput nvoDiginput12 nvoDigOutput nvoDigOutput12 can be propagated resent SCPTminSendTime Defines the minimum wait time before the 119 nciVsmdMinOutTm network output variables can be propagated resent SCPTminSetpoint Defines the minimum speed of the motor as 120 nciMinSpeed a percentage of the nominal speed defined by the Nominal Speed SCPTnomRPM nciNmlSpeed configuration value SCPTnomFreq Sets the nominal frequency of the motor 121 nciNmlFreq SCPTnomRPM Sets the nominal motor speed 122 nciNmiSpeed SCPTrampDownTm Sets the ramp down time of the drive 123 nciRampDownTm SCPTrampUpTm Sets the ramp up time of the drive 123 nciRampUpTm UCPTbypRunDelay Additional pick up delay for bypass contactor 124 nciBypRunDelay UCPTadrvCurntLimit Drive current limit 124 nciDrvCurntLimit UCPTparReadlndex Chooses the parameter value to be read 125 nciParReadIndex from the drive Network variables 108 Name Description More info on page UCPTparValue Value input for the user selected parameter 125 nciParWrite Value U
39. degrees C 92 nvoNetCtrl Indicates the LonWorks network is selected 93 as the active control source Network variables 55 Name Description More info on page nvoNetRef1 Indicates the LonWorks network is selected 94 as the active reference REF1 source nvoNetRef2 Indicates the LonWorks network is selected 95 as the active reference REF2 source nvoParReadValue Data read at parameter set by 96 UCPTparReadIndex nciParReadindex nvoPid1Dev PID controller deviation values 97 nvoPid2Dev nvoPid1Fbk PID controller feedback values 98 nvoPid2Fbk nvoReady Indicates the drive is ready to receive a start 99 command nvoReverse Indicates the drive is running in the reverse 100 direction nvoRunning Motor running state 101 nvoSpeedActRpm Output speed in rpm 102 nvoStarted Indicates the drive has received a start 103 command nvoStatus Reports the node object status 104 nvoZeroSpeed Indicates the drive is at zero speed 105 Network variables 56 nvoAccelerating Definition Network output SNVT_switch nvoAccelerating Explanation Indicates the drive is accelerating Valid range State Value Status 0 0 0 Not accelerating 1 100 0 Accelerating When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartb
40. e has not been established NODE STATE Explanation Contains the current state of the network interface Configured on line is the normal run time mode and means that the node is commissioned and on line on the network Soft Bypass Hard Drive bypass configuration 27 off line means that the node is not participating actively on the network The byte has the following bit assignments B x x x M S S S B bypass x not used M mode S state Bxxx MSSS State XXXX x011 Unconfigured without application XXXX x010 Unconfigured with application XXXX x110 Configured hard offline Oxxx 1100 Configured soft offline 1Xxx 1100 Configured bypass offline Oxxx 0100 Configured offline NEURON ID Explanation Displays the Neuron chip ID of the module in decimal format The ID is determined by the chip and cannot be changed Par 3 NEURON ID 5 byte 6 of the unique Neuron ID MSB Par 4 NEURON ID 4 byte 5 of the unique Neuron ID Par 5 NEURON ID 3 byte 4 of the unique Neuron ID Par 6 NEURON ID 2 byte 3 of the unique Neuron ID Par 7 NEURON ID 1 byte 2 of the unique Neuron ID Par 8 NEURON ID 0 byte 1 of the unique Neuron ID LSB The decimal values of the parameters are converted to Neuron ID as shown by this example Parameter 3 4 04h Parameter 4 118 76h Parame
41. eat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 57 nvoAlarm Definition Network output SNVT_switch nvoAlarm Explanation Indicates the drive has an alarm Valid range State Value Status 0 0 0 No alarm 1 100 0 Alarm When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 58 nvoAnlginput 1 nvoAnlginput8 Definition Network output SNVT_lev_percent nvoAnlgInput1 Network output SNVT_lev_percent nvoAnlgInput2 Network output SNVT_lev_percent nvoAnlgInput3 Network output SNVT_lev_percent nvoAnlgInput4 Network output SNVT_lev_percent nvoAnlgInput5 Network output SNVT_lev_percent nvoAnlgInput6 Network output SNVT_lev_percent nvoAnlgInput7 Network output SNVT_lev_percent nvoAnlgInput8 Explanation Each variable indicates the value of the corresponding analog input 1 8 of the host Valid range Va
42. erating SNVT_switch defined SNVT_switch nviEmrgOverride nvoAlarm 102 SNU has amara network 202 SNVT_switch 103 mio za variables 204 nvoBypKwh_R _switc SNVT_elec_kwh_1I as Sie nviResetFault nvoBypTemp 105 SNVT_switch 206 SNVT_temp_p ie ae eee ior Sees ly nviStariEnable1 nvoDrvDCBus 108 SNVT_switch 209 SNVT_volt nviStartEnable2 nvoDrvKwh_NR 109 SNVT_switch 210 SNVT_elec_kwh_I 211 nvoDrvkwh_R SNVT_elec_kwh_I nvoDrvTemp 212 SNVT_temp_p nvoDrvTorque 213 SNVT_lev_percent 214 nvoEmrgOvrdStat SNVT_hvac_emerg nvoEnabled 215 SNVT_switch nvoExt1Ext2Stat 216 SNVT_switch nvoFaultCode 217 SNVT_switch Communication 34 Manufacturer defined network variables ages gt as aan 21 h Za ee ge Ze pe A A Caray O za ee zo mene a ee Ss eae oe A 235 Sv tev percent A OET i a goes a zaa pene A A O Communication 35 Manufacturer defined configuration properties ncABB nciDrvCurntLimit ncABB11 nciParWritelndex ncABB2 nciPid1Gain ncABB13 nciBypRunDelay ncABB3 nciPid1IntTime ncABB14 nciPid2Gain ncABBA nciPid1DerTime ncABB15 nciPid2IntTime ncABB6 nciStopMode ncABB17 nciPid1DerFiltTi ncABB7 nciStopLevel ncABB18 nciPid2DerFiltTi ncABB39 nciParWriteValue ncABB20 nciPid2DerTime ncABB10 nciParReadindex L Open loop actuator object DigitalCommand
43. for information on the selection parameters Drive bypass configuration 31 Communication Overview General This chapter describes the FLON 01 operation on a LONWorRKs network In LONWORKS networks the network design emphasis is on designing the network variable connections The connection design determines the amount of data flow between different nodes thus determining the decision of transmission media and network topology overall in the network In designing the connections the selection of protocol services is also crucial when determining the network data flow By default the network connections use acknowledged messaging with a certain retry count This can however be changed by the installation tool to optimize the overall network performance To be able to realize the required operation of the whole system a clear picture of the capabilities of individual nodes is needed These capabilities are determined by the network variables Communication 32 LONMARK objects The FLON 01 includes a node object a drive object and several open loop sensor or actuator objects The node object is used to control the drive object The drive object realizes the LONMARK Functional Profile Variable Speed Motor Drive Version 1 1 The profile defines a set of network variables and configuration properties In addition the drive object includes a set of manufacturer defined network variables and configur
44. gnostics 134 Diagnostics 135 Definitions and abbreviations BAC Building Automation Controller Communication Module Communication Module is a parameter name parameter selection name for a device e g a fieldbus adapter through which the drive bypass is connected to an external serial communication network e g a fieldbus The communication with the communication module is activated by a parameter CRC Cyclic Redundancy Check FLON 01 A device through which an ABB drive or bypass is connected to a LONWOoRKS network Functional profile Functional profiles may contain one or more objects that interact to perform the required profile defined operability The Variable Speed Motor Drive Profile contains the general LONMARK Node Object application specific Variable Speed Motor Drive Object and the Open Loop Sensor and Open Loop Actuator objects LonMarke Products that conform to LONMARK Interoperability Guidelines defined by the LONMARK Interoperability Association are eligible to carry the LONMARK logo LonTalke The communication protocol in LONWoRKS networks LSB Least significant bit Definitions and abbreviations 136 MSB Most significant bit nci Network configuration variable Neuron ID Every LONWoRKS device or as synonym node must have a unique ID This is called the Neuron ID This ID is on Neuron Chip based nodes stored in the chip itself and cannot be changed
45. guration value if used Network variables 74 nvoDrvPwr Definition Network output SNVT_power_kilo nvoDrvPwr Explanation Drive power in kilowatts Valid range Value Power 0 0 0 kW 65534 6553 4 kW 65535 Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 75 nvoDrvRunHours Definition Network output SNVT_time_hour nvoDrvRunHours Explanation Total operation time for the motor by the drive in running hours Valid range Value Time 0 0 0h 65534 65534 h 65535 Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 76 nvoDrvSpeed Definition Network output SNVT_lev_percent nvoDrvSpeed
46. han the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 89 nvoLineVolt Definition Network output SNVT_volt nvoLineVolt Explanation Provides the drive input voltage in volts Valid range Value Voltage 0 0 0V 3276 6 3276 6 V Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 90 nvoLocRemStat Definition Network output SNVT_switch nvoLocRemStat Explanation This output variable shows if the drive is in Local or Remote control mode Valid range State Value Control mode 0 0 Local 1 100 Remote When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 91 nvoMtrRevC
47. his value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 60 nvoAnlgSts1 nvoAnlgSts8 Definition Network output SNVT_lev_percent nvoAnlgSts1 Network output SNVT_lev_percent nvoAnlgSts2 Network output SNVT_lev_percent nvoAnlgSts3 Network output SNVT_lev_percent nvoAnlgSts4 Network output SNVT_lev_percent nvoAnlgSts5 Network output SNVT_lev_percent nvoAnlgSts6 Network output SNVT_lev_percent nvoAnlgSts7 Network output SNVT_lev_percent nvoAnlgSts8 Explanation Each variable indicates an analog status 1 8 from the host Configuration and mapping of these points is host specific Valid range Value Analog status 32768 163 84 32766 163 83 Ox7FFF Invalid When transmitted This value is transmitted immedi significantly Additionally this ne ately when its value has changed work variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 61 nvoAtReference Definition Network output SNVT_switch nvoAtReference Explanation Indicates the drive is at reference Valid range State Value Status 0 0 0 Not at reference 1 100 0 At reference
48. iAnlgSndHrtBt nc52 nciAnlgMinOutTm J Open loop sensor object Analoginput Analoginput gt Manufacturer defined 1 nvoAniginputt 8 network variables SNVT_lev_percent Manufacturer defined configuration properties nc49 nciAnlgSndHrtBt nc52 nciAnigMinOutTm H Open loop sensor object AnalogOutput AnalogOutput Manufacturer defined nvoAnlgOutput1 8 network variables SNVT_lev_percent Manufacturer defined configuration properties nc49 nciAnigSndHrtBt nc52 nciAnigMinOutTm a Communication 38 Resource files For the installation of the FLON 01 with different installation tools resource files are needed If you have not received these files together with the FLON 01 please consult your local ABB representative The resource files are delivered as a compressed ZIP archive Copy the ZIP archive to your LonWorks directory and unpack the compressed files The directory LONWORKS TYPES USER ABB FLON holds the user type and enumeration file VSD_FLONO1 TYP the user type formatting file VSD_FLON01 FMT the functional profile template file VSD_FLONO1 FPT and the language file VSD_FLONO1 ENU The directory LONWORKS IMPORT ABB FLON holds the external interface files XIF XIF version 2 0 e g FLON_V20 XIF XIF version 3 1 e g FLON_V31 XIF XIF version 4 1 e g FLON_V41 XIF XIF version 4 4 e g
49. iVsmdMinOutTm configuration value if used Network variables 87 nvoLimit Definition Network output SNVT_switch nvoLimit Explanation Indicates the drive has reached a speed frequency or torque limit Valid range State Value Status 0 0 0 Within limits 1 100 0 Out of limits When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 88 nvoLineUVVolt nvoLineVWVolt nvoLineWUVolt Definition Network output SNVT_volt nvoLineUVVolt Network output SNVT_volt nvoLineVWVolt Network output SNVT_volt nvoLineWUVolt Explanation Each variable provides the corresponding line to line input voltage in volts Valid range Value Voltage 0 0 0 V 3276 6 3276 6 V Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster t
50. in order to operate correctly and in order to select different modes Furthermore some of the configuration network variable values receive their defaults from the drive bypass The drive bypass control location parameters should also be set accordingly to enable full and logical operation of the FLON 01 See chapter Drive bypass parameter settings Drive bypass configuration 26 FLON 01 information parameters Fieldbus par no Parameter name Description 1 MODULE TYPE Type of the module LonWorks 2 NODE STATE State of the FLON 01 3 8 NEURON ID 5 0 Neuron chip ID 9 NODE ADRESS 1 ID of the node within this subnet 10 NODE SUBNET 1 Subnet 1 to which the node belongs 11 16 DOMAIN ID 1 4 0 Domain ID in a LonWorks network 17 NODE ADRESS 2 ID of the node within this subnet 18 NODE SUBNET 2 Subnet 2 to which the node belongs 19 24 DOMAIN ID 2 4 0 ID in a LonWorks network 25 XMIT ERRORS Number of CRC errors 26 TRANS TIMEOUTS Number of transmission failures Note These parameters become visible in the drive only after the FLON 01 has been configured on the network side MODULE TYPE Explanation Shows the module type as detected by the drive bypass The value cannot be adjusted by the user If this parameter is undefined the communication between the drive and the modul
51. lue Analog input value 32768 163 84 32766 163 83 Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 59 nvoAnlgOutput1 nvoAnlgOutput8 Definition Network output SNVT_lev_percent nvoAnlgOutput1 Network output SNVT_lev_percent nvoAnlgOutput2 Network output SNVT_lev_percent nvoAnlgOutput3 Network output SNVT_lev_percent nvoAnlgOutput4 Network output SNVT_lev_percent nvoAnlgOutput5 Network output SNVT_lev_percent nvoAnlgOutput6 Network output SNVT_lev_percent nvoAnlgOutput7 Network output SNVT_lev_percent nvoAnlgOutput8 Explanation Each variable indicates the value of the corresponding analog output 1 8 of the host Valid range Value Analog output value 32768 163 84 32766 163 83 Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate T
52. lue has changed significantly Additional y this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 64 nvoBypTemp Definition Network output SNVT_temp_p nvoBypTemp Explanation Provides the bypass PCB temperature in degrees C Valid range Value Temperature 27317 273 17 C 0 0 C 32767 327 67 C When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 65 nvoCtlOverrideSt Definition Network output SNVT_switch nvoCtlOverrideSt Explanation Indicates that the LONWorks network has overridden other control and reference sources Valid range State Value Control source 0 0 0 Other 1 100 0 Network When transmitted This value is transmitted immediately when its value has changed significantly Additionally this ne
53. network nviResetFault Input to the motor to clear the fault status in 50 the drive nviRunEnable Sets the run enable for the host 51 Network variables 40 Name Description More info on page nviSavePars Request for parameter save to non volatile 51 memory by network nviStartEnable1 Sets start enable 1 for the host 52 nviStartEnable2 Sets start enable 2 for the host 52 Network variables nviAnlgCmd1 nviAnlgCmd8 Definition Network input SNVT_lev_percent nviAnlgCmd1 Network input SNVT_lev_percent nviAnlgCmd2 Network input SNVT_lev_percent nviAnigCmd3 Network input SNVT_lev_percent nviAnlgCmd4 Network input SNVT_lev_percent nviAnlgCmd5 Network input SNVT_lev_percent nviAnlgCmd6 Network input SNVT_lev_percent nviAnlgCmd7 Network input SNVT_lev_percent nviAnlgCmd8 Explanation Each variable supplies an analog command 1 41 8 to the host Configuration and mapping of these points is host specific Valid range Value Analog command 32768 163 84 32766 163 83 Ox7FFF Invalid Default value 0 Network variables 42 nviCtlOverrideCm Definition Network input SNVT_switch nviCtlOverrideCm Explanation Indicates that the LONWorks network requests override of control and references sources by the network Valid range State Value Override command 0 0 No override 1 100 Network overrides control and status
54. ns and abbreviations ooooooooommmmmomom o 135 Technical data noanean e A A AA 139 FRONT a tas 139 LonWorksO NStWOrk coda a ees eee AS 140 Table of contents 12 Table of contents 13 Introduction Intended audience The manual is intended for the people who are responsible for commissioning and using an FLON 01 LonWorks Adapter module The reader is expected to have a basic knowledge of electrical fundamentals electrical wiring practices and how to operate the drive Before you start It is assumed that the drive bypass is installed and ready to operate before starting the installation of the extension module In addition to conventional installation tools have the drive bypass manuals available during the installation as they contain important information not included in this manual The manuals are referred to at various points of this document What this manual contains This manual contains information on the wiring configuration and use of the FLON 01 LonWorks Adapter module Safety instructions are featured in the first few pages of this manual Overview contains a short description of the LonWorks system and the FLON 01 LonWorks Adapter module and a delivery checklist Mechanical installation contains placing and mounting instructions for the module Electrical installation contains the wiring instructions Drive bypass configuration explains how to program the drive bypass
55. ntM Definition Network output SNVT_count_32 nvoMtrRevCntM Explanation Accumulated revolutions of the motor in millions Valid range Value Motor revolutions 0 0 1 1 000 000 4294967295 4 294 967 295 000 000 When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 92 nvoMtrTemp Definition Network output SNVT_temp_p nvoMtrTemp Explanation Motor temperature in degrees C Valid range Value Temperature 27317 273 17 C 0 0 C 32767 327 67 C When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 93 nvoNetCtrl Definition Network output SNVT_switch nvoNetCtrl Explanation Indicates the LoNWoRrks network is sele
56. o 8 from the host 69 nvoDigSts12 nvoDrvCurnt Drive current in amperes 70 nvoDrvDCBus Drive DC bus voltage 71 nvoDrvKwh_NR Value of the non resettable drive kWh counter 72 nvoDrvKwh_R Value of the resettable drive kWh counter 13 nvoDrvPwr Drive power in kilowatts 74 Network variables 54 Name Description More info on page nvoDrvRunHours Operation time for the motor by the drive in 75 whole hours nvoDrvSpeed Speed of the drive as a percentage of the 76 nominal speed nvoDrvTemp Temperature in degrees C 77 nvoDrv Torque Output torque as a percentage of motor 78 nominal torque nvoDrvVolt Motor output voltage 79 nvoEmrgOvrdStat Feedback for nviEmrgOverride 80 nvoEnabled Indicates the drive has received the run 81 enable command nvoExt1Ext2Stat Control location currently used EXT1 EXT2 82 nvoFaultCode Latest malfunction code that has occurred 83 nvoFaulted Information on the fault status of the drive 84 nvoForward Indicates the drive is running in the forward 85 direction nvoFregAct Output frequency in Hz 86 nvoLimit Indicates the drive has reached a speed 87 frequency or torque limit nvoLineUVVolt Line to line input voltages in volts 88 nvoLine VWVolt nvoLineWUVolt nvoLineVolt Drive input voltage 89 nvoLocRemStat Control mode Local or Remote 90 nvoMtrRevCntM Accumulated revolutions of the motor in 91 millions nvoMtrTemp Motor temperature in
57. of the host Valid range State Value Digital output status 0 0 Inactive 1 100 Active When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 69 nvoDigSts1 nvoDigSts12 Definition Network ou Network ou Network ou Network ou Network ou Network ou Network ou Network ou Network ou Network ou Network ou Network ou Explanation put SNVT_switch nvoDigSts1 put SNVT_switch nvoDigSts2 put SNVT_switch nvoDigSts3 put SNVT_switch nvoDigSts4 put SNVT_switch nvoDigSts5 put SNVT_switch nvoDigSts6 put SNVT_switch nvoDigSts7 put SNVT_switch nvoDigSts8 put SNVT_switch nvoDigSts9 put SNVT_switch nvoDigSts10 put SNVT_switch nvoDigSts11 put SNVT_switch nvoDigSts12 Each variable indicates a digital status 1 12 from the host Configuration and mapping of these points is host specific Valid range State Value Digital status 0 0 Inactive 1 100 Active When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network va
58. ork Through the FLON 01 LonWorks9 Adapter module it is possible to give control commands to the drive bypass Start Stop Run enable etc feed a motor speed or frequency reference to the drive give a process actual value or a process reference to the PID controller of the drive read status information and actual values from the drive change drive parameter values reset a drive fault control other LoNWoRrks nodes The network variables and functions supported by the FLON 01 LonWorks Adapter module are discussed in chapters Drive bypass configuration Communication and Network variables The adapter module is mounted into an option slot on the motor control board of the drive or bypass See the drive documentation for module placement options Overview 17 LonWorks nodes APB FLON 01 LONWORKS ADAPTER paa ABB Drive ES ON Diagnostic LEDs faananau L See chapter HOST ji ji bess RETHORR MOET ere O ETC BARA AAA A x Service pin tl Chassis screw Bus connector X1 see chapter Electrical installation Figure 1 The construction of the LONWorks network and the FLON 01 Adapter module Compatibility The FLON 01 interoperates with all LonWorks devices Note LoNWorks supports a variety of media The F
59. rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 104 nvoStatus Definition Network output SNVT_obj_status nvoStatus Explanation Reports the node object status Valid range Bit settings Description Function invalid_id Invalid node ID requested report_mask Reporting supported fields disabled RQ_DISABLE active electrical_fault Fault bit in Status Word in_alarm Alarm bit in Status Word Network variables 105 nvoZeroSpeed Definition Network output SNVT_switch nvoZeroSpeed Explanation Indicates the drive is at zero speed Valid range State Value Status 0 0 0 Not at zero speed 1 100 0 At zero speed When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 106 Supported network configuration properties All configuration properties are defined as configuration network variables in this product Some network management tools will show these variables as SCPT UCPT configuration propertie
60. rcent of nominal speed as defined by the Nominal Speed SCPTnomRPM nciNmlSpeea configuration value The value of the maximum speed must be defined so that 163 840 lt minimum speed lt maximum speed lt 163 830 Valid range Value Maximum speed 32768 163 840 32766 163 830 32767 Invalid Default value Read from host on power up Network variables SCPTminSendTime nciAnigMinOutTm Definition 117 Network config input SNVT_time_sec nciAnlgMinOutTm Explanation Defines the minimum wait time before network output variables nvoAnlgSts1 nvoAnlgSts8 nvoAniginput1 nvoAniginput8 nvoAnlgOutput1 nvoAnigOutput8 can be propagated resent Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 5s Network variables 118 SCPTminSendTime nciDigMinOutTm Definition Network config input SNVT_time_sec nciDigMinOutTm Explanation Defines the minimum wait time before network output variables nvoDigSts1 nvoDigSts12 nvoDigInput1 nvoDiginput12 nvoDigOutput1 nvoDigOutput12 can be propagated resent Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 5s Network variables SCPTminSendTime nciVsmdMinOutTm Definition 119 Network config input SNVT_time_sec nciVsmdMinOutTm Explanation
61. riable should be set to 0 to enable the next reset fault Default value No action state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time Network variables 51 nviRunEnable Definition Network input SNVT_switch nviRunEnable Explanation Sets the run enable for the host Valid range State Value Command 0 0 Run disabled 1 100 Run enabled Default value Run disabled state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time nviSavePars Definition Network input SNVT_switch nviSavePars Explanation Indicates that the LONWorks network requests parameters be saved to non volatile memory Valid range State Value Command 0 0 Do nothing 1 100 Save parameters Default value Do nothing state 0 value 0 This value will be adopted at power up Network variables 52 nviStartEnable1 Definition Network input SNVT_switch nviStartEnable1 Explanation Sets start enable 1 for the host Valid range State Value Command 0 0 Start 1 disabled 1 100 Start 1 enabled Default value Start 1 disabled state 0 value 0 This value will be adopted at power up and in case of not receiving an update within the specified Receive Heartbeat time
62. riable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 70 nvoDrvCurnt Definition Network output SNVT_amp nvoDrvCurnt Explanation Drive current in amperes Valid Range Value Current 0 0 0A 32766 3276 6 A Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 71 nvoDrvDCBus Definition Network output SNVT_volt nvoDrvDCBus Explanation Drive DC bus voltage Valid range Value Voltage 0 0 0V 3276 6 3276 6 V Ox7FFF Invalid When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be upd
63. rom external control circuits even when the drive mains power is shut off Exercise appropriate care when working on the unit Neglecting these instructions can cause physical injury or death Safety instructions Safety instructions Table of contents Safety instructions oooooocccorornerraa E ds GEU i5 A 5 A A A a E A Nas aee BEE Gace Rte seh thle ao E A 5 General safety instructions oooococcccocor 5 Table of contents ii a a eon md es E 7 Introduction Lita A Ad he 13 Intended audience oooocccocccc tee etee 13 Before you Starte ae biases nae kel Gti ida dees 13 What this manual contains o ooooococccccc eee ee 13 Further informations e aeaii at aa nae E dela ia ala 14 Ove rvieW eass iae onn n PATE o EE Rothe a a aia Ha 15 OVEINVIEW cta a tt a daa FREER es 15 The Lon WorksO system oooccccocccoo eee 15 The FLON 01 LonWorks Adapter module o oococccccoo o o 16 Compatibility ua rt A AA tas 17 Delivery check ios nd 18 Mechanical installation ooooooooccrrnrrmomommmooooo 19 Mounting sta e a ee oe 19 Electrical installation 00 0 cece cece ene ene 21 Overview cintia ae lia end dal a ah AS 21 General cabling instructions s an 00 cece eet eee 21 NetWork CONNECT Da 22 Bus termination a e E eh eed het eae Weel dd whe 22 Earthing the LonWorks cable screens 000 eee eee eee 23 Table of contents 8 Drive bypass configuration
64. s 110 SCPTmaxRcvTime nciAnlgRcvHrtBt Definition Network config input SNVT_time_sec nciAnlgRcvHrtBt Explanation Controls the maximum time that elapses after the last update of nviAnlgCmd1 nviAnlgCma8 before the default values are used Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no failure detect Network variables SCPTmaxRcvTime nciDigRcvHrtBt Definition 111 Network config input SNVT_time_sec nciDigRcvHrtBt Explanation Controls the maximum time that elapses after the last update of nviDigCma 1 nviDigCmd12 before the default values are used Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no failure detect Network variables 112 SCPTmaxRevTime nciVsmdRevHrtBt Definition Network config input SNVT_time_sec nciVsmdRcvHrtBt Explanation Controls the maximum time that elapses after the last update of the network variables before the VSMD object starts to use its default values Valid range Value Time 0 Disabled 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no failure detect Network variables SCPTmaxSendTime nciAnlgSndHrtBt Definition 113 Network config input SNVT_time_sec nciAnlgSndHrtBt Explanation Defines the maximum period of time that e
65. s and some as network configuration variables The difference in the network management tools only affects the presentation of the variables but not their functionality Name Description More info on page SCPTdefScale Default value for nviDrvSpeedScale 109 nciDrvSpeedScale SCPTlocation Location label 109 nciLocation SCPTmaxRcvTime Defines the maximum time after the last 110 nciAnlgRcvHrtBt update of nviAnigCmd7 nviAnigCmd8 SCPTmaxRcvTime Defines the maximum time after the last 111 nciDigRcvHrtBt update of nviDigCma 1 nviDigCmd12 SCPTmaxRevTime Defines the maximum allowed update 112 nciVsmdRevHrtBt interval for input network variables nviDrvSpeedStpt and nviDrvSpeedScale SCPTmaxSendTime Maximum time that expires before network tis nciAnlgSndHrtBt variables nvoAnlgSts1 nvoAnlgSts8 nvoAnlginput nvoAniginput8 nvoAnlgOutput1 nvoAnlgOutput8 will automatically be updated SCPTmaxSendTime Maximum time that expires before network 114 nciDigSndHrtBt variables nvoDigSts1 nvoDigSts12 nvoDigInput1 nvoDigInput12 nvoDigOutput1 nvoDigOutput12 will automatically be updated SCPTmaxSendTime Maximum send time for the variable 115 nciVsmaSndHrtBt nvoDrvSpeed SCPTmaxSetpoint Defines the maximum motor speed 116 nciMaxSpeed Network variables 107 Name Description More info on page SCPTminSen
66. ter 5 213 D5h Drive bypass configuration 28 Parameter 6 244 F4h Parameter 7 1 01h Parameter 8 0 00h These decimal parameter values yield a Neuron ID of 0476D5F40100h NODE ADRESS 1 Indicates the ID of the node within the subnet Range 1 127 0 node address 1 not assigned NODE SUBNET 1 Explanation Indicates to which subnet the node belongs Range 1 255 0 node subnet 1 not assigned DOMAIN ID 1 Explanation Indicates the ID of the domain within this subnet Each domain in a LonWorks network has a unique ID of 0 1 3 or 6 bytes in length If the ID is shorter than 6 bytes it is left justified in this field DOMAIN ID 1 5 byte 6 of the domain ID MSB DOMAIN ID 1 4 byte 5 of the domain ID DOMAIN ID 1 3 byte 4 of the domain ID DOMAIN ID 1 2 byte 3 of the domain ID DOMAIN ID 1 1 byte 2 of the domain ID DOMAIN ID 1 0 byte 1 of the domain ID LSB NODE ADRESS 2 Explanation Indicates the ID of the node within this subnet Drive bypass configuration 29 Range 1 127 0 node address 2 not assigned NODE SUBNET 2 Explanation Indicates to which subnet the node belongs Range 1 255 0 node subnet 2 not assigned DOMAIN ID 2 Explanation Indicates the ID of the domain within this subnet Each domain in a LonWorks network has a unique ID of 0 1 3 or 6 bytes in length If the ID is shorter than 6 bytes it is left justified in this field DOMAIN
67. transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 100 nvoReverse Definition Network output SNVT_switch nvoReverse Explanation Indicates the drive is running in the reverse direction Valid range State Value Status 0 0 0 Not reverse 1 100 0 Reverse When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 101 nvoRunning Definition Network output SNVT_switch nvoRunning Explanation Indicates the motor running state Valid range State Value Status 0 0 0 Not running 1 100 0 Running When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable
68. tual capacitance 58 nF km 74 nF km 56 nF km 100 nF km of a pair Max pair to ground 3 28 nF km capacitance unbalance Nominal 102 Q 15 at impedance 950 at 100 Qat 772 kHz 1 0 MHz 1 0 MHz 100 2 15 at 1 4 8 10 16 and 20 MHz Max attenuation 15 dB km at 772 kHz at 20 C 18 dB km at 1 0 MHz 36 dB km at 4 0 MHz 49 dB km at 8 0 MHz 56 dB km at 10 0 MHz 72 dB km at 16 0 MHz 79 dB km at 20 0 MHz Pair twists 20 20 5 per metre nominal minimum minimum Technical data 142 LONWORKs network cable specifications Control General Data grade JY St Y signalling purpose level 4 2x2x0 8 grade grade 22 AWG 20 4 AWG 16 AWG 16 AWG 0 65 mm 0 8 mm 1 3 mm 1 3 mm Cable parameters single single twisted pair single or wire pair twisted pair twisted pair multiple typically solid red black stranded stranded and unshielded per DIN 19 29 19 29 VDE 0815 unshielded unshielded 4 wire Tefzel PVC helical Insulation amp Insulation twist solid Jacket High amp Jacket shielded 150 C max Medium 80 C max LONWORKS network maximum bus lengths Control General Data JY St Y signalling purpose grade 2x2x0 8 grade grade level 4 16 AWG 16 AWG 22 AWG 20 4 AWG 1 3 mm 1 3 mm 0 65 mm 0 8 mm Bus Doubly length 2200 m 2200 m 1150 m 750 m terminated bus topology Stub 3m 3m 3m 3m length Node to Singly node 500 m 400 m 400 m 320 m
69. twork variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 66 nvoDecelerating Definition Network output SNVT_switch nvoDecelerating Explanation Indicates the drive is decelerating Valid range State Value Status 0 0 0 Not decelerating 1 100 0 Decelerating When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables nvoDigInput1 nvoDigInput12 Definition Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInput7 Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_switch nvoDigInpu Network output SNVT_swi Net
70. ue has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 83 nvoFaultCode Definition Network output SNVT_switch nvoFaultCode Explanation Provides the current fault DRIVECOMM reported by host Valid range Value Fault code 0 65535 DRIVECOMM fault code When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 84 nvoFaulted Definition Network output SNVT_switch nvoFaulted Explanation Provides information on the fault status of the host Valid range State Value Status 0 0 0 Not faulted 1 100 0 Faulted When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as
71. vel Explanation Stop level value in ramp stop mode When the speed of the drive reaches this level a coast stop is performed The value is relative to nvoDrvSpeed i e the value of 5 corresponds to nvoDrvSpeed value 5 Valid range Value Stop level 32768 163 84 32766 163 83 32767 Invalid Default value 5 Network variables 132 UCPTstopMode nciStopMode Definition Network config input SNVT_switch nciStopMode Explanation s used to select between coast and ramp stop Valid range State Value Stop mode 0 0 0 Coast 1 100 Ramp Default value Coast state 0 value 0 0 Network variables Diagnostics 133 LED indications The FLON 01 module is equipped with three bicolour diagnostic LEDs The LEDs are described below DU HOST IRK MODULEC NETWORK C r Name Colour Function Green Connection to host OK HOST y Establishing communication to host Flashing red i n or communication to host lost Off Off Initializing Invalid Unconfigured with or without Red Teh application Configured offline hard soft or Yellow MODULE bypass Flashing yellow Con igured online with receive timeout Flashing green Wink Green Configured online Yellow Transmitting NETWORK Green Receiving Off Inactive Dia
72. work output SNVT_switch nvoDigInpu Explanation 67 DOIORAON 8 9 10 ch nvoDiginput11 12 Each variable indicates the status of the corresponding digital input 1 12 of the host Valid range State Value Digital input status 0 0 Inactive 1 100 Active When transmitted This value is transmitted immediately when its value has changed significantly Additionally this network variable will also be transmitted as a heartbeat output on a regular basis as specified by the Maximum Sent Time nciVsmdSndHrtBt configuration value Update rate This value will be updated no faster than the Minimum Send Time nciVsmdMinOutTm configuration value if used Network variables 68 nvoDigOutput1 nvoDigOutput12 Definition Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne work ou work ou work ou work ou work ou work ou work ou work ou work ou work ou work ou work ou Explanation put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi put SNVT_swi ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutput4 ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutput8 ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutpu ch nvoDigOutpu Wh 5 6 7 9 10 11 12 Each variable indicates the status of the corresponding digital output 1 12
73. xpires before network variables nvoAnlgSts1 nvoAnlgSts8 nvoAnlginput nvoAnlginput8 nvoAnlgOutput 1 nvoAnlgOutput8 will automatically be updated Valid range Value Time 0 No automatic update 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no automatic update Network variables 114 SCPTmaxSendTime nciDigSndHrtBt Definition Network config input SNVT_time_sec nciDigSndHrtBt Explanation Defines the maximum period of time that expires before network variables nvoDigSts1 nvoDigSts12 nvoDigInput nvoDiginput12 nvoDigOutput1 nvoDigOutput12 will automatically be updated Valid range Value Time 0 No automatic update 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no automatic update Network variables 115 SCPTmaxSendTime nciVsmdSndHrtBt Definition Network config input SNVT_time_sec nciVsmdSndHrtBt Explanation Defines the maximum period of network variables will automatically be updated Valid range Value Time 0 No automatic update 1 0 1s 65534 6553 4 s 65535 Invalid Default value 0 no automatic update ime that expires before the Network variables 116 SCPTmaxSetpoint nciMaxSpeed Definition Network config input SNVT_lev_percent nciMaxSpeed Explanation Used to define the maximum motor speed The value is entered as a pe