1. 7 ENJOY CLAIRE cosmetic device for the treatment of cellulite model 3 0 user manual ENJOY CLAIRE Contents Msingore STo dol 2 Properties of the AeVICC ccccceeeeeeeee eee ee ee eee ee ences eens sees ea eseseeaeeesasaesaseeasseseeaeseeeeors 3 DEVICE components 22 eis lake nan cede NMT aii Eliade ne dine gene e gela LERRA 4 Description of control panel rere nnne ne nene ve vedi nino venne seen ine ove dive ve va 5 Description of rear panel eere nnde n evanida ei nuda roarai er na 6 Instruction VON gui 7 Maintenance se RR REOR ED REED eee nhau uh e dle vele ella te vet 10 IMPORTANT INSTRUCTION LLL e nemen hehe e eremi e eese e nene nnns 10 Technical data failures sess memes messe senes sen nnn nnn 12 ENJOY CLAIRE Introduction ENJOY Claire is a magnetotherapeutic device that offers ladies a comfortable way of getting rid of the unpleasant orange peel appearance Its therapeutically acting components are planar pulsed magnetic field and heat which accelerate the metabolism of fatty cells and remove waste products and toxins via the lymphatic system The two types of energy are generated by a planar applicator and penetrate into the body only to a depth of a few millimeters It is sufficient to remain in sitting or lying position and let the pleasant heat of the applicator act for at least an hour a day regularly for a period of 20 days To facilitate the lymph draining through the lymp
2. Signal lamp of IMF degree 3 ENJOY CLAIRE Description of rear panel Main switch Power supply connector Program facility connector oom Applicator output ENJOY CLAIRE Instruction on use CONNECTING AND PUTTING INTO OPERATION 1 Place the control unit 1 on a firm base Put the textile cover 4 on the applicator and close the zippers the inscription APPLICATION SIDE being on the outside The textile cover does not protect the applicator against dampness sweat apply therefore a disposable absorbent pad 5 which is placed between the textile cover and the body 4 Place the applicator on the therapy site a chair armchair bed etc Take care that during application the inscription APPLICATION SIDE is towards the body Connect the power supply 2 to the connector B of the control unit 1 Do not cover the power supply lest it should be damaged Connect the supply cable 3 to the power supply 2 and then to a mains socket technical data To speed up the healing effect we recommend switching on and preheating the device some 30 minutes prior to application Cover the applicator with a blanket to prevent its cooling After the above period switch the device off and proceed as given under 2 and 3 below 7 ENJOY CLAIRE PREPARATION FOR THERAPY 1 Sit down on the applicator and tighten the belts with Velcro fasteners around the thighs Be aware that an
3. hatic system it is recommended to have the legs slightly raised during application A pronounced change can only be expected after a fortnight For a prolonged preservation of the result achieved it is recommended to repeat the treatment in shorter or longer intervals as may be necessary The same as in skin cosmetics in the case of cellulite too it is necessary to avoid blemishes by preventive stimulation of metabolism which this device does ENJOY CLAIRE Properties of the device adjustable magnetic field intensity MFI on the applicator surface control of 43 C max temp as a protection against skin overheating automatic switching off after 60 minutes operation or in case of failure using a very low voltage in order to increase user safety high effectiveness which reduces operating costs and environmental damage possibility of washing the applicator cover in current detergents ENJOY CLAIRE Device components 1 ENJOY Claire control unit inclusive of the applicator 2 Power supply 24 V 2 7A SYS 1183 6524 3 Supply cable 4 Textile cover of applicator 5 Disposable absorbent pad 4 6 User manual 6 7 Carrier bag ENJOY CLAIRE Description of control panel MFI degree 1 on off applicator surface temperature ca 39 C MFI degree 2 on off applicator surface temperature ca 41 C MFI degree 3 on off applicator surface temperature ca 43 C Signal lamp of IMF degree 1 Signal lamp of IMF degree 2
4. l before using the device for the first time Keep the user manual for later reference The device does not substitute any therapeutic facility designed for medical application in hospitals If you are in doubt as to your health condition contact your doctor before using the device Do not use the device during pregnancy Do not use the device in your sleep and do not apply it to people while they are unconscious 10 Do not use the device for longer than 2 hours without a break of several hours Do not apply the applicator to skins that are oversensitive diseased or under treatment Terminate the application immediately you notice any unpleasant sensation During application check occasionally the condition of the skin exposed to treatment Do not open or modify any part of the device Do not disconnect the device by pulling the mains cable ENJOY CLAIRE 9 Use only original accessories supplied 10 Do not expose the device to direct by the manufacturers the power sunshine high temperatures or supply in particular chemicals CAUTION The device is not designed for use by persons children included whose physical and mental disabilities or lack of experience and knowledge prevents them from using the device safely unless they are supervised or have been advised about the functioning of the device by a person responsible for their safety The device should be kept out of the reach of children The device is no
5. t designed for playing with z ie ENJOY CLAIRE Technical data failures ENJOY CLAIRE POWER SUPPLY UNIT Model Char MO5N V3 Input voltage AC 110 240 V 50 60 Hz Power supply DC 24 V 2 7 A Output voltage DC 24 V Power input 65 W Output current 2 7 A Therapy duration setting 60 min Output power 65 W Maximum applicator temperature 43 C Protection class II double insulation Trans dimensions l w h 450 450 110 mm Output connector 2 1 x 5 5 mm Failures If after switching on the device the three signal lamps d e and f are not blinking or if the chosen required MFI degree cannot be obtained and a continuous sound signal is heard or if the device gets disconnected prematurely switch the device off by the main switch A and disconnect it from the mains After five seconds connect the device and switch it on again If the problem persists contact the vendor 12 ENJOY spol s r o Loosova 355 12 638 00 Brno ID 46968270 Czech Republic www enjoy cz info enjoy cz
6. y layer of clothes reduces the healing effect During application lift your legs to a slightly higher position SWITCHING THE DEVICE ON AND THERAPY PROPER 1 Turn the main switch A to position I on the rear panel of the control unit 1 and check whether all the free control signal lamps lights d e f on the control panel are blinking Choose one of the MFI degrees by pushing the respective button a b c on the control panel 1 From now on the device is in operation and the signal lamp of the 8 chosen MFI degree must give continuous light After an hour the therapy will automatically be terminated you will be warned by a sound signal You can terminate the therapy before due time by repeatedly pushing the same button During the therapy you can change the MFI degree to your liking ENJOY CLAIRE SWITCHING THE DEVICE OFF 1 When the therapy is over turn the switch A to position O and check whether all the three signal lamps d e and f go out Withdraw the supply cable 3 from the mains socket Maintenance Before cleaning or washing the textile cover take it off the applicator Set the washing temperature to 30 C at the most After cleaning or washing dry the cover thoroughly but do not iron it Do not wash the applicator or the control unit Do not use aggressive chemicals when cleaning or washing the cover ENJOY CLAIRE IMPORTANT INSTRUCTIONS Read the user manua
Download Pdf Manuals
Related Search
Related Contents
MA16x und MA17x 取扱説明書 電気カーペット HC-20B2D-T、HC-30B2D-T The jOOQ™ User Manual USER MANUAL - Beacon Innovation International Inc. Manuale Utente - Kawai Musical Instruments Manufacturing Co., Ltd. 製品安全データシート - 大日本スクリーン製造 USER'S MANUAL Of VIA CX700M Chipset Based ACCIDENT 1er août 2008 - ULM identifié EC-ZIX Evénement V7 CAT5e UTP Network Cable 0,5 (RJ45 m/m) blue 0,5m Copyright © All rights reserved.