Home
User Manual BS 15 [ASL]
Contents
1. PAGE 4 User Manual TS 120 November 2013 ASL Intercom BV 8 0 OPERATING A CUE LIGHT SYSTEM Described below is how to operate a cue light system consisting of one TS 120 master station and a number max 12 of TS 10 cue light receivers For a description of how to operate a cue light system with the TS 99 preset control unit see section The TS 99 a On the TS 120 push the ATTN button of those channels you want to send an attention signal to The LEDs of the selected channels now flash red indicating that they are in attention mode A channel which does not have a TS 10 cue light receiver connected cannot be put in attention mode the LED of that channel does not switch on The ATTENTION lights of the chosen TS 10 s are now flashing The reception of an attention signal can be acknowledged by pushing the ACKN button on the TS 10 s The large red ATTN lights are now continuously lit The LEDs of the corresponding channels of the TS 120 are now lit continuously red indicating that the receivers have acknowledged the reception of the attention signal Push the GO button s of these channels on the TS 120 Their LEDs are now lit continuously green and the GO signal is sent to the TS 10 s One can also push the All selected channels GO button by which the GO signal is sent to all selected channels simultaneously The GO signal can also be sent to channels which have not received an acknow
2. TS 120 CUE LIGHT MASTER STATION TS 10 CUE LIGHT RECEIVER TS 99 PRESET CONTROL USER MANUAL November 2013 This product is designed and manufactured by ASL Intercom B V Zonnebaan 42 3542 EG Utrecht The Netherlands Phone 31 0 30 2411901 Fax 31 0 30 2667373 E mail info asl inter com Web www asl inter com CONTENT OF THIS USER MANUAL 1 0 INTRODUCTION sisssscascsnassacdeasscniscsswersisedtiensndseiacstesttdanedadsassaghocsasdendsassonieeus 3 20 UNPACKING ene en ee eee een ee 3 30 INSTALLATION isa cst cecesctcasantcesdecndsenenspenconcesaceocensctancatedantaiciedeascaateesteceue iste 3 4 0 WARRANTY idudsestennticcsuenencncennedeneccsss Fout Bladwijzer niet gedefinieerd 5 0 TS 120 FRONT PANEL GONTROLS eeen eenen eneeneneneneneenen 3 6 0 TS 120 REAR PANEL CONNECTORS onee neen ene nen ern ennnen 4 7 0 TS 10 CUE LIGHT RECEIVER oaeen eeen eenenennervenen eenen 4 8 0 OPERATING A CUE LIGHT SYSTEM assistentieteam 5 9 0 TS 120 INTERNAL CONTROLS aaneen ennen neen en ennen venenvenen 4 10 0 TS 120 TECHNICAL SPECIFICATIONS aaneen eneenenren eneen 5 11 0 THE TS 99 PRESET CONTROL an eneen eneen eneen en eenen vennen 6 12 0 USING THE TS 99 PRESET CONTROL aaneen eeen 6 PAGE 2 User Manual TS 120 November 2013 ASL Intercom BV 1 0 INTRODUCTION A cue light system consist of TS 120 master stations and TS 10 cue light receivers A TS 120 master station has 12 cue ligh
3. go from ATTN to GO the corresponding LED s go from red to green and the GO signal is sent to the to the referring TS 10 s User Manual TS 120 November 2013 ASL Intercom BV e Push the GO button on the TS 99 again All channels are now cleared the LED s on the TS 120 s and the GO lights on the TS 99 s extinguish f One may select another preset and start the next attention and go sequence Between step c and d there might be an acknowledgement phase from the TS 10 s an acknowledgement signal has been sent to the corresponding TS 120 channels Whether an acknowledgement signal has been received is not shown on the TS 99 only on the TS 120 s the LED s of the referring channels go from flashing red to continuously red PAGE 8 User Manual TS 120 November 2013 ASL Intercom BV
4. S 485 negative signal PAGE 5 User Manual TS 120 November 2013 ASL Intercom BV 10 0 THE TS 99 PRESET CONTROL 1 PROGRAM button To put the unit into program mode 2 STORE button To store a preset 3 3 DISPLAY 4 Showing the preset number 4 SELECT PRESET buttons To select a preset number max 99 numbers 5 5 PRESET VIEW button 6 To show the selected preset on the TS 120 6 ATTENTION button To send an attention signal from all linked TS 120 s to all in the preset stored channels 7 GO button To send an go signal from all linked TS 120 s to all channels stored in the preset The TS 99 connects to the TS 120 via a cable of 1 5m which is fixed to the TS 99 One may lengthen this cable to max 10 m The TS 99 is powered by the TS 120 via this cable 5V DC 11 0 USING THE TS 99 PRESET CONTROL With the TS 99 one may operate a cue light system consisting of one TS 120 and a number of connected TS 10 s One can store up to 99 Cue presets and control the ATTN GO and CLEAR button of the TS 120 s using the ATTN and GO buttons of the TS 99 When several TS 120 s are linked one has to operate such a system with the TS 99 to make it a one multi channel max 144 cue light system Programming amp storing a preset a Select the requested preset number with the left and right SELECT PRESET buttons b Push the PROGRAM button The TS 120 s are now in program mode and show
5. ledgement of the sent attention signal It is not possible to send a GO signal to channels which are not in attention mode On the connected TS 10 s the large ATTN light extinguishes and the large GO light illuminates This is the take action sign After the cue is executed push the CLEAR button of the TS 120 The LEDs on the TS 120 which are lit green the corresponding channels are in go mode extinguish as well as the GO lights on the TS 10 s The LEDs on the TS 120 which are flashing or continuously lit red the corresponding channels are in attention mode remain illuminated and stay available for a GO procedure The TS 120 can be programmed in such a way that by pushing the CLEAR button all LED s extinguish so the ones of the channels which are in go mode and the ones of the channels which are in attention mode For programming see section Internal Controls The cue light system is now ready for the next Cue an Attention Acknowledge and Go sequence 9 0 TS 120 TECHNICAL SPECIFICATIONS Dimensions amp Weight Mains voltage 100 240 V AC 50 60 Hz Width 480 mm Power Consumption max 60 Watts Height 88 mm Power to TS 10 s 30V DC Depth 126 mm weight 1200 grams Pin configuration Sub D9 connectors Pin 4 RS 485 positive signal ASL reserves the right to alter specifications Pin 5 5V DC to TS 99 without prior notice Pin 7 GND Pin 8 R
6. low blow type The total cable length between all linked 8 MAINS entrance TS 120 s should not be more than 100 m Accepts any voltage from 100 240 VAC 50 60 Hz 11 XLR connectors These twelve XLR 3 connectors are for 9 LINK IN connector connecting the TS 10 s Pin assignments To this Sub D9 connector the TS 99 preset 1 0 V ground shield control is connected This connector is also for A 30 V power wire linking two TS 120 s the TS Link Cable coming 3 signalling line from another TS 120 goes to this LINK IN connector 6 0 TS 120 INTERNAL CONTROLS On the far left of the bottom PCB are a number of small slide switches Slide Switch Ne 7 Slide Switch Ne 8 By moving this slide from the OFF to the ON By moving this slide from the ON to the OFF position one puts the TS 120 into demonstration position the TS 120 is programmed in such a mode All its functions may be demonstrated way that when pushing the CLEAR button all without necessarily having any TS 10 connected LED s extinguish so the ones of the channels which are in go mode and the ones of the channels which are in attention mode 7 0 TS 10 CUE LIGHT RECEIVER The TS 10 cue light receiver has a large ATTENTION light a large GO light and an acknowledge ACKN button The unit is powered by a TS 120 via the microphone cable which is connected to the XLR 3 on the TS 10 rear panel The maximum cable length between a TS 120 and a TS 10 is 100 m
7. t channels each having an ATTN attention push button and a GO push button accompanied by a bi color LED indicator Furthermore the TS 120 has an All selected channels GO button and CLEAR button Up to twelve TS 120 units can be linked to each other resulting in 144 cue light channels The units are linked via the D connectors on the rear panels using the TS Link Cable Linked TS 120 s are operated by a TS 99 control unit The TS 120 may be connected to mains voltages from 100 240 V AC 50 60 Hz 2 0 UNPACKING A TS 10 cue light receiver has a large red ATTENTION light an ACKN acknowledge push button and a large green GO light TS 120 master stations and TS 10 cue light receivers are interconnected by standard microphone cable two conductors and one shield with XLR 3 connectors Use high quality microphone cable only Cue light receivers are powered 30V DC bya TS 120 via the microphone cable The TS 120 is designed to have only one TS 10 on each output XLR More than one TS 10 connected to an output would disturb the proper functioning of both the TS 120 and the TS 10 After unpacking the unit please inspect for any physical damage to the unit and retain the shipping carton and relevant packing materials for use should the unit need returning 3 0 INSTALLATION If any damage has occurred please notify your dealer immediately so that a written claim can be initia
8. ted The TS 120 requires a vertical rack size of 2U 2 5 89 mm It is not necessary to provide rear support by extra bracing or shelving Adequate ventilation must be provided by allowing sufficient soace around the sides and rear of the unit to ensure free circulation of air After a period of time the internal power supply will feel hot to the touch This is quite normal and should be no cause for alarm 4 0 TS 120 FRONT PANEL CONTROLS 1 ATTENTION button To activate ATTENTION for that channel 2 GO button To activate the GO for that channel 3 Indicator LED This LED indicates the status of the channel Off ATTN Acknowledged or GO 4 All selected channels GO button This push button activates the GO function for all channels which are in Attention mode 5 CLEAR button With this button all channels which are in GO mode can be switched off simultaneously it clears the channels for the next action See also section internal Controls User Manual TS 120 November 2013 ASL Intercom BV 5 0 TS 120 REAR PANEL CONNECTORS WARMING THES UMET MILIST BE EARTHED E Ni HESH VER PAGE INSIDE De SONNECT MAINS INPUT BEFORE REMOVING COMER 6 8 F 10 1 6 MAINS power switch 10 LINK OUT connector To switch the unit On and Off This connector is used for linking two TS 120 s From this LINK OUT connector the TS Link Cable 7 FUSE holder goes to another TS 120 The fuse needs to be a 1 25 A s
9. the content of the chosen preset number the LED s of the channels in this preset are flashing green c Push the GO buttons of the channels you want to add to this preset Push the GO buttons of the channels you want to remove from this preset d To store the just re configured preset push and hold the STORE button until the TS 120 s go out of their program mode and return to normal operation PAGE 6 User Manual TS 120 November 2013 ASL Intercom BV Previewing a preset a Select the requested preset number with the left and right SELECT PRESET Activating a preset attention and go a Have a look at the display In case there buttons Push and hold the PREVIEW button The content if any of the selected preset is shown on the TS 120 s The LED s of the in this preset stored channels are flashing green PAGE 7 is a preset presently active in an Attention and Go sequence this is indicated by a blinking dot next to the preset number Before another preset can be selected the Attention and Go sequence of this active preset must first be completed Select the requested preset number with the left and right SELECT PRESET buttons Push the ATTN button on the TS 99 All channels stored in the selected preset go into attention mode and the attention signal is sent to the corresponding TS 10 s Push the GO button on the TS 99 All channels stored in the selected preset
Download Pdf Manuals
Related Search
Related Contents
Manuel d`utilisation Sony UP-CR10L Photo Printer User Manual AUTORISATION PARTICULIERE N° A/1692 Bedienungsanleitung RadioCom 4.5 製品組立・取扱説明書 P214KWT (MPM)取扱説明書 Ithaca 9000 Programmer`s Guide Samsung MM-ZJ5Q Инструкция по использованию Copyright © All rights reserved.
Failed to retrieve file