Home
Cosmo & Mido - Adina Heating Products
Contents
1. 56700020 55015140 56700058 44300120 55000100 GB 6
2. 1 Introduction Congratulations on your new wood burning stove By now you have probably installed the stove already and maybe lit the stove for the first time as well To most people operating instructions are something you consult when everything else fail especially if you have had a wood burning stove in your home for several years In spite of this we still hope that you will take a little time to read these operating instructions since the use of a wood burning stove is an individual matter depending on which model you have Before you can fully enjoy being the owner of a wood burning stove you need to get to know it well This is not difficult however it does take a little bit of patience For further infor mation on heat stoking combustion problems and maintenance please refer to Jydepejsen s Manual for installation and stoking Please also refer to the illustrations in the back 2 Installation Jydepejsen stoves are tested by specialist institutions and approved according to applicable legislative requirements Before final approval is granted stoves have to successfully complete a variety of combustion tests The stove tested featured a top outlet The wood used for the tests was birch with a moisture content of 15 21 Jydepejsen s professional distributors will be able to advise you on the requirements for this type of wood burning stove and provide further instruction regarding correct installation Your distributor chi
3. and depends on the stove usage The wearing parts are Vermiculite panels baffle plates sealing band Furthermore Glass and soapstone are not covered by the warranty If any of the above mentioned need replacing new parts can be ordered from your dealer 4 Stoking instructions It is very important to ensure that your chimney has a decent draught The Alpha and Omega is the cooperation between the chimney and the stove Your dealer or your chimney sweep will be able to guide and advice you on your chimney conditions When this is settled the next step is that you make the stove and the chimney cooperate This is done by following the operating instructions and using fuel which inflames easily in the combustion chamber until a decent draught is obtained For further information on correct lighting and stoking please refer to Jydepejsen s Manual for installation and stoking GB 3 4 Please note that the stove paint will harden during the first few initial lightings This means that the stove will generate smoke and an odour of paint which will dissipate after about 1 hours s operation It is a good idea to ensure effective ventilation during this phase Also touching the stove should be avoided since this may cause the paint to scale The stove will expand and contract during the lighting and cooling phase possibly resulting in creaking noises This phenomenon is completely normal for sheet iron stoves and cannot be regarded as a fa
4. dy and calm flames nu hh YN 5 Maintenance Sealing band and vermiculite panels are wearing parts which need to be renewed How often this is needed depends on how much you use your stove In some cases every year others every second or third year A principal rule is that the sealing band needs renewal when it is flattened and the door no longer fits tightly against the front of the stove A new set of sealing band with glue can be purchased from your local dealer Vermiculite panels must be renewed when they are worn thin or when possible cracks are so wide that you can actu ally see steel through them If the panels are not renewed on such occations they lose their power of insulation and heat reflection Movable and mechanical parts should be greased once a year with a heat resisting lubricant closing mechanisms hinges etc GB 4 5 Renewal of the sealing band at the door 1 Remove the sealing band from the inner frame and clean the band mark it is not necessary to remove the door from the stove Add a band of heat resistant glue on the band mark Push new sealing band down into the mark Close the door and let the glue harden for about 24 hours before you open the door again If you do not let the glue harden sufficiently before you open the door the band may fall out Renewal of the sealing band between the Glass and the door of the stove NEN DD It is not nescessary to remove the door Dismount bolts Glas
5. mney sweep will also be able to tell you exactly which chimney you need Below you can see illustrations of mounted stoves with and without isolated firetubes Distance to combustible with insulated flues Distance to combustible with insulated flues 350 Distance to combustible without Distance to combustible without insulated flues insulated flues AM 200 All local regulations including those which refer to national and European standards must be observed when installing a wood burning stove You must ensure that there is sufficient intake of combustion air also when used with other heating and extraction devices Houses today are often so well insulated that it may be necessary to take in fresh air from outside via fresh air vents Fresh air vents should not be blocked GB 1 2 You should also check that the vermiculite plates are correctly fitted inside the combustion chamber The position of these is shown in the illustration in this instruction manual You must install your stove according to the required minimum distance to combustible materials See also the boiler plate on the stove for details In addition it is important to check that the Vermiculite panels are correctly fitted in the combustion chamber The wood holder in the combustion chamber is not to be removed Floor foundation wall The stove must be installed hanged on a non combustible fou
6. ndation at a non combustible wall i e where a tile or brick floor is non existing the stove must meet the demands for the distance to combustible material under above beside the stove according to applicable legislative requirements Consult you dealer before installing the stove 3 Warranty Brand new wood burning stoves from Jydepejsen A S come with a 5 year warranty The warranty includes defects and burn through with correct operation Any claims during the warranty period should be directed to the dealer who sold the stove All stoves from Jydepejsen come with their own individual serial number on the type plate on the back of the stove Please quote stove model and serial number to your dealer in connection with service tasks In the event of warranty repairs a signed and dated invoice must also be produced showing the dealer s name The warranty does not cover dismantling transport and reassembly of your stove No compensation will be granted for Damage during transport Damage to other articles resulting from use of the stove Damage arising from misoperation or incorrect usage such as overheating avoid this by reading the operating instructions carefully The directions in the operating instructions have not been followed The stove is supplied with wearing parts which are to be replaced due to usage of the stove These parts are not covered by the warranty how often they are to be replaced is individual
7. sholders from the door Dismount the bolt and the ratchet that hold the handle Remove the glass Remove the old sealingband from the door Add new sealing band to the door Insert the glass and tighten the bolts and the glassholders Change of the vermiculite panels Be Le we re Take out the front smoke deflector plate Push the rear edge of the baffle plate upwards to take out the rear panel in the combustion chamber Remove the two small bevelled side panels Remove thae two side panels in front Now you can remove the lower baffle plate Then lastly remove the top smoke deflector plate GB 5 6 Spare parts list Type Vermicul Vermicul Vermicul Vermicul Vermicul Vermicul Vermicul Vermicul Vermicul We are only able to deliver a complete vermiculiteset and not single parts Glass iteset lower baffle plates incl ite side panel right ite side panel left ite side panel left bevelled ite side panel right bevelled ite rear panel ite baffle plate upper ite baffle plate rear ite baffle plate front Cast iron bottom T Ash pan Gasket with glue Shaking grate Description 400 x 148 3 x 25 mm 400 x 148 3 x 25 mm 395 254 4 x 140 9 x 29 mm 395 254 4 x 140 9 x 29 mm 271 6 x 237 1 x 29 mm 378 258 x 220 x 15 mm 390 268 9 x 180 3 x 20 mm 385 x 155 x 20 mm 485 x 340 x 4mm hickness 9 mm Capacity 4 2 12mm Article no 44101000 0
8. ult All Jydepejsen wood burning stoves are intermittent which means that new wood should be added when there is a layer of embers in the burning chamber Once there is a good bed of embers in the stove you can add wood It is important not to open the door while there are flames in the stove as this may cause smoke to flow out into the room Add wood on the basis of your heating require ments The amount of wood you need to add will depend on the season However never add more than 2 kg of wood every 1 5 2 hours Please remember that the exterior surfaces of the stove in particular will become very hot during firing Initial lighting Turn the air intake to the maximum Add firelighters and billets to the bottom of the fire box combustion chamber The billets about 1 5 kg are to be built up crosswise Light the fire The door should be ajar for a couple of minutes during the lighting phase The air intake must be adjusted down after approx 10 minutes how much depends on the chimney draught howe ver the air supply must be diminished to the point where you obtain steady and calm flames A a aati ero Stoking Turn the air intake to the maximum To minimize the underpressure the door should be ajar for about one minute before you open it completely Open the door slowly Add 2 3 pieces of firewood to the combustion chamber Close the door Turn down the air supply when the fire has caught the wood to obtain stea
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL: JCI 247 Faraday Pail DVD 楽ナビマップ Getting started Section I - Perfectpass.com Wentronic 67172 television antenna Compex 各部のなまえ 取付手順 仕様 設置上のお願い Imprimer le mode d`emploi Copyright © All rights reserved.
Failed to retrieve file