1. 6 Cabling 12 Wiring the Power Inputs 12 Wiring the Fault Alarm Contact 13 3 Mounting Installation 14 DIN Rail Mounting 14 Wall Mount Plate Mounting 16 4 Hardware Installation 17 Installation Steps 17 5 Network Application 18 6 Troubles shooting 19 7 Technical Specification
2. Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD 7 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Description Straight Through Cable Schematic Cross Over Cable Schematic 2 Gigabit Copper SFP Mini GBIC combo port The EIR418 2SFP T has two auto detect Giga ports copper Fiber combo ports The Gigabit Copper 10 100 1000T ports should use Category 5e or above UTP STP cable for connection The SFP slots support dual mode which can switch the connection speed between 100 and 1000Mbps These SFP slots can be used to connect the network segment with single or multi mode fiber You must choose appropriate mini GBIC module to plug into the slots Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard With the SFP module fiber optic connection the switch can transmits speed up to 1000 Mbps and you can prevent noise interference from the system and get extended transmission distance depending on the SFP module used Note The SFP Copper Combo port can t both be used at the same time The SFP module has the highest priority If a 1000M SFP transceiver is inserted into the SFP cage and a remote device is connected to the SFP port the copper combo Hardware Description 8 Manual Documentation Number EIR418 2S
3. 20 Introduction 1 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Introduction The EIR418 2SFP T is an industrial DIN mount unmanaged 18 port Ethernet switch with Gigabit capability It has 16 10 100 copper Ethernet ports and 2 Gigabit Combo ports that support copper or SFP module connections Features System Interface Performance o RJ 45 ports support Auto MDI MDI X Function o SFP mini GBIC supports 100 1000 Dual Mode o Store and Forward Switching Architecture o Back plane Switching Fabric 7 2Gbps o 1Mbits Packet Buffer o 8K MAC Address Table o Supports Wide Operating Temperature 40oC to 75oC Case Installation o IP30 Protection o DIN Rail and Wall Mount Design Power Supply o Wide Range Redundant Power Design o Power Reverse Polarity Protected o Overload Current Protection Provides EFT protection 3 000 VDC for power line Supports 6 000 VDC Ethernet ESD protection Introduction 2 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Package Contents 1 EIR418 2SFP T 18 Port Gigabit Industrial Ethernet Switch 1 Quick Start Guide 1 CD ROM with User Manual 2 Wall Mounting Bracket and Screws 3 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Description Hardware Descr
4. 3 amp 4 Note The wire gauge for the terminal block should be 12 to 24 AWG 14 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Mounting Installation Mounting Installation DIN Rail Mounting The DIN rail clip comes screwed on to the switch from the factory If the DIN rail clip is not screwed on the switch please see the following figure to re attach the DIN Rail clip Then follow the steps below to hang the switch onto a DIN rail 1 Use the screws to screw the DIN rail clip onto the switch 2 To remove the DIN rail clip reverse step 1 15 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Mounting Installation 3 First insert the top of DIN rail clip onto the piece of the DIN rail track 4 Then lightly push the bottom of the switch so it can snap the rest of the way onto the DIN rail track 5 Check that the switch is held tightly to the DIN rail track 6 To remove the switch from the track reverse the steps above First pushing down lightly on the switch will give enough room for the bottom of the switch to clear the bottom of the DIN rail track 16 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Mounting Installation Pulling slowly at the bottom of the switch will bring the switch out so that the switch can now be carefully lifte
5. Color standard EIAfTIA T568B Ethernet Patch Cable TX I Z72J T gt lt c J R RJ45 Pin Pin RJ45 Orange White Tracer 1 1 Orange White Tracer Orange 2 2 Orange Green White Tracer J J Green White Tracer Blue 4 4 Blue Green 6 6 Green PR2 PRJ1l PRJ Blue White Tracer 5 5 Blue White Tracer Brown White Tracer 7 7 Brown White Tracer Brown 8 8 Brown riii J PR4 Color standard EIAfTIA T568B Ethernet Crossover Cable RJ45 Pin Green White Tracer J l7llZl Orange White Tracer 1 Orange 2 Blue 4 Blue White Tracer 5 Green 6 Brown White Tracer 7 Brown 8 Blue White Tracer B is most recent Common Ethernet Crossover Cables may only cross connect the Orange amp Green pairs Hardware Description 10 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com To connect the transceiver and fiber cable follow the steps shown below Note SFP modules typically terminate with an LC fiber connector First insert the SFP transceiver into the SFP module cage Notice that the triangle mark is at the bottom of the module Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard Transceiver Inserted Hardware Description 11 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europ
6. ED The port is disconnected or operates at speed of 10 100M P17 P18 Link Active 100 1000 SFP Green SFP port is connected to network Blinking Networking is active Off Not connected to network 6 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Description Ports RJ 45 ports Eight RJ 45 ports auto sense for 10 100 Mbps while two ports auto sense for 10 100 or 1000 Mbps device connections The auto MDI MDIX feature allows connections to switches workstation and other equipment without changing straight through or crossover cabling The charts below show the cable pin assignments for straight through and crossover cables RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of wire pair All copper ports on the EIR418 2SFP T support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cables pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD
7. FP T 0912m fVININ bb elec com fVININ bb europe com RJ45 Pin Pin RJ45 Green White Tracer Green Orange White Tracer Blue 1 2 3 4 1 2 3 4 Green White Tracer Green Orange White Tracer Blue Blue White Tracer Orange Brown White Tracer Brown 5 6 7 8 5 6 7 8 Blue White Tracer Orange Brown White Tracer Brown port will link down If a 1OOM SFP transceiver is inserted into the SFP cage the copper combo port will link down regardless of the connection status of the remote device RJ 45 Male Plug 8765432 1 12345678 12345678 RJ 45 Female Color standard EIAfTIA T568A Ethernet Patch Cable TX r ill ii TX RX lt Zl2 r ill ii RX J r ill ii Color standard Ethernet Crossover Cable EIAfTIA T568A r ill ii Green White Tracer 1 1 Orange White Tracer RJ45 Pin Pin RJ45 Green 2 2 Orange t272 Orange White Tracer 3 3 Green White Tracer Blue 4 4 Brown White Tracer r ill ii Blue White Tracer 5 5 Brown J Orange 6 6 Green r ill ii Brown White Tracer 7 7 Blue Brown 8 8 Blue White Tracer A is earlier Hardware Description 9 Manual Documentation Number EIR418 2SFP T 0912m fVININ bb elec com fVININ bb europe com Pin RJ45 1 Green White Tracer 2 Green J Orange White Tracer 4 Brown White Tracer 5 Brown 6 Orange 7 Blue 8 R gt lt c J
8. Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com EEIIR R441188 22SSFFPP TT U Usseerr M Maannuuaall i Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com UUssiinngg ddoommeessttiicc aanndd iimmppoorrtteedd ppaarrttss bbyy EEIIR R441188 22SSFFPP TT DDooccuum meennttaattiioonn NNuum mbbeerr EEIIRR441188 22SSFFPP TT 00991122m m IInntteerrnnaattiioonnaall HHeeaaddqquuaarrtteerrss B amp B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com European Headquarters B amp B Electronics Ltd Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 Website www bb europe com 2008 B amp B Electronics Mfg Co Inc No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitment on the part of B amp B Electronics Mfg Co Inc B amp B Electronics Mfg Co Inc shall not be liable for incidental or consequential damages resulting from the furnishing performance or use of this manual All Brand names used in this manual
9. are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder Table of Contents ii Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Table of Contents 1 Introduction 1 Features 1 Package Contents 2 2 Hardware Description 3 Physical Dimension 3 Front Panel 3 Top View 4 LED Indicators 4 Ports
10. d off the DIN rail track Wall or Panel Mount Plate Mounting Follow the steps below to mount the switch with the wall mount plate 1 Remove the DIN rail clip from the switch loose the screws to remove the DIN rail clip 2 Place the wall mount plate on the rear panel of the switch 3 Use the screws to screw the wall mount plate onto the switch 4 Use the hook holes at the corners of the wall mount plates to hang the industrial switch on the wall 5 To remove the wall mount plate reverse the above steps 17 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Installation Hardware Installation Installation Steps 1 Unpack the switch 2 Check if the DIN rail clip is screwed on the Industrial switch or not If the DIN rail clip is not screwed onto switch please refer to DIN Rail Mounting section for DIN Rail installation If the user wants to wall mount or panel mount the switch then please refer to Wall or Panel Mount Plate Mounting section for wall plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer to the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED
11. e com Second insert the fiber cable into the transceiver LC connector to the transceiver To remove the LC connector and SFP transceiver follow the steps below First press the upper side of the LC connector down and pull it out before releasing Remove LC connector Hardware Description 12 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Second swivel the metal latch away from the switch and pull the transceiver out Pull out from the SFP module Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable 10Mbps Use category 3 4 5 or greater cable 100Mbps Use category 5 or greater 1000Mbps Use category 5e or greater cable Cable distances should be less than 100 meters 328 ft long Wiring the Power Inputs Follow the steps below to insert the power wire 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector Hardware Description 13 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com 2 Tighten the wire clamp screws for prevent the wires from becoming loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as shown below If one of the power sources fails a fault will be detected causing the circuit to open Insert the wires into the fault alarm contact No
12. iption Physical Dimension W x D x H is 72mm x 105mm x 152mm 2 8 x 4 1 x 6 0 inches Front Panel The front panel of the EIR418 2SFP T is shown below 4 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Description Top View The top panel view of the EIR418 2SFP T is equipped with one terminal block connector that consists of two 12 to 48 VDC power inputs and the fault alarm output LED Indicators LED Status Meaning PWR1 Green Power 1 is active Off No power at input 1 PWR2 Green Power 2 is active Off No power at input 2 Fault Red PWR1 or PWR2 has failed Off PWR1 amp PWR2 are both active or no power is applied 5 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Hardware Description Green Upper LED Connected to network Blinking Upper LED Networking is active P1 to P16 Off Upper LED Not connected to network Yellow Lower LED Ethernet port full duplex Blinking Lower LED Off Lower LED Collision of packets occurs Ethernet port half duplex or not connected to network Green Upper LED Connected to network P17 P18 10 100 1000T Blinking Upper LED Off Upper LED Networking is active Not connected to network Green Lower LED The port is operating at speed of 1000M Off Lower L
13. lights 5 Prepare the twisted pair straight through Category 5 above cable for Ethernet connection 6 Insert one end of UTP STP cable into the Industrial switch RJ 45 port and the other end to the network device s RJ 45 port e g Switch PC or Server The RJ 45 port LED on the Industrial switch will light up when the cable is connected with the network device Please refer to the LED Indicators section for LED light indication 7 When all connections are set and LED lights all show in normal the installation is complete 18 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Network Application Network Application The diagram below shows a typical switch installation for the EIR418 2SFP T 19 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Troubleshooting Troubleshooting Verify that you are using a power supply ranging from 12 to 48VDC Applying more than 48VDC could cause damage to the switch Be sure the proper cable is used in your network Refer to the Cabling section of this manual for help Diagnosing LED Indicators The switch can be monitored through the LED indicators on the front panel of the switch The LED s can help describes common problems you may encounter and where you may find possible solutions to assist in identifying problems If the power indicators do not light on whe
14. n power is applied you may have a problem with the power supply Check for loose power connections power losses or surges at the power outlet If the switch LED s represent normal operating mode and the cable connections are correct and no data is transmitted or received through the switch contact your Network Administrator for network configuration and status help Technical Specification 20 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Technical Specification Standard IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T IEEE 802 3z Gigabit fiber IEEE 802 3x Flow Control and Back pressure Protocol CSMA CD Transfer Rate 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX FX Fast Ethernet port 1 488 000 pps for Gigabit Fiber Ethernet port MAC address 8K MAC address table Packet Buffer 1Mbits LED Per unit Power 1 Green Power 2 Green Fault Red 16 10 100TX Link Activity Green Full duplex Collision Yellow Gigabit Copper Link Activity Green speed 1000M Green SFP Link Activity Green Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000Base T 2 pair UTP STP Cat 5e or 6 cable EIA TIA 568 100 ohm 100m Technical Specification 21 Manual D
15. ocumentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com Optical cable Multi mode 50 125um or 62 5 125um Single mode 9 125um Back plane 7 2Gbps Packet throughput ability 10 7Mpps at 64bytes Power Supply 12 to 48 VDC Redundant power with polarity reverse protection and removable terminal block Power Consumption 9 Watts Install DIN rail kit for DIN type cabinet and wall mount ear for wall mount install Operating Temp 40oC to 75oC Operating Humidity 5 to 95 Non condensing Storage Temperature 40oC to 85oC Case Dimension IP30 72 mm W x 105 mm D x 152mm H 2 8 x 4 1 x 6 0 inches EMI FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Technical Specification 22 Manual Documentation Number EIR418 2SFP T 0912m www bb elec com www bb europe com CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration