Home
iDRAC7 Networking and Improved Remote Access
Contents
1. feature for Rack and Tower systems and it is available by default on blade servers This feature allows an administrator to mount a virtual drive to a remotely located server from a CD DVD USB drive or an ISO image file on his local machine Together with the iDRAC7 virtual console for remote desktop the administrator can copy files install drivers applications or operating systems to a server in a different location 4 iDRAC7 Networking and Virtual Media Performance Introduction In the Dell PowerEdge 12th generation servers the iDRAC7 processor is significantly faster than previous generations The CPU clock speed is more than double the 11 generation speed 576MHz vs 220 MHz and the SoC System on a Chip also features a dual execution pipeline giving further gains in processing capacity as a result throughput of a networking intensive application such as Virtual Media running on iDRAC7 is much greater than before In some cases networking devices and protocols have a more noticeable impact on the performance than the core CPU speed on iDRAC7 Virtual Media is the example used in this paper as a networking intensive application because its data rate is important to the user and it could be affected by the network and iDRAC7 configuration To implement virtual media the iDRAC7 emulates a USB mass storage device interfacing with the server s main processor Over the management network the server s iDRAC7 i
2. 620 blade Windows7 64 bit Disabled N A 39 24 Java plug in Note Table 1 Sample of results from Virtual Media testing Note1 This number demonstrates a gain achieved by configuring the client to 100Mbps speed 13 iDRAC7 Networking and Virtual Media Performance Conclusion Network performance can vary drastically and it has been the subject of many years of intense research and development By understanding some fundamental characteristics of your network environment performance can be optimized Dell PowerEdge 12 Generation servers offer compelling opportunities for performance improvements in the IT professional s management network The iDRAC7 in particular has been upgraded to improve the systems management experience for those charged with that task About the authors Andy Butcher is a Principal Software Engineer and Tim Lambert is a Senior Systems Engineer who work together on the management subsystem solution for PowerEdge servers The authors would like to particularly acknowledge and credit Doug Roberts software engineer for the tireless collection of data and insight provided for this paper A great deal of credit is deserved also to Florin Dragan software engineer and our colleagues in our Bangalore Design Center Shine K A Anshul Simlote and Tharakarama Raju for their attention to performance improvements in iDRAC7 Thanks also to Chip Webb and Rich Hernandez for their technical expertise and to Phil Webster for c
3. anagement Use of Virtual LANs is supported to logically partition management traffic from host server traffic Due to the use of VLANs less physical switch ports are required to support and manage Management link redundancy reduces the chance for loss of remote server management communication Automatic link failover can be configured where any LOM port can be assigned to be the primary shared network port The failover network can be designated to any specific LOM port or to all LOM ports in a round robin fashion for systems supporting more than 2 LOM ports such as the R620 and R720 These options provide flexibility in failover control especially in configurations where LOMs can be of different network types such as 2 gigabit ports and 2 10 gigabit ports More fabric flexibility Since flexible LOMs provide options that include 1 gigabit 10 gigabit copper and SFP interfaces the management network interface can utilize any of these or future interfaces or fabrics Shared network port functionality is available with or without iDRAC7 Enterprise license If iDRAC7 Enterprise license is enabled then the shared network ports are still available for use The shared network ports support auto negotiation forced speed and duplex static IP and DHCP Shared network ports support IPv4 IPv6 auto negotiation forced speed and duplex static IP and DHCP The same iDRAC7 MAC address is used if the server is configured to use dedicated or shared netwo
4. ave extreme effects on network performance If a half duplex port is talking to a link partner whose setting is for full duplex erroneous collision detection can occur and invoke legacy recovery mechanisms used when CSMA CD was necessary on local area networks Duplex mismatch can occur if network ports are intentionally configured for a certain duplex setting but it can also occur if auto negotiating ports fall back to half duplex to talk to a full duplex partner be aware of this phenomenon and ideally configure all network ports to 1Gbps auto negotiate 100Mbps configuration If duplex mismatch can be avoided and the illustrations in Figure 2 apply to your environment and management workstations are used exclusively for that activity consider configuring the NIC card and the accompanying managed switch port to 100Mbps speed full duplex By doing this the traffic from the potential Virtual Media data sender is matched to the speed that it is sent to its destination Flow control becomes less of an issue and dropped packets become unlikely because the devices routing to the iDRAC7 are sending as fast as they are receiving Disabling large send offload If this setting is available in your client machine management station network interface card settings it can be disabled to decrease the chances of dropped packets Large send offload is a feature of network cards that allows a software application to send data of sizes larger than the MTU
5. ffic can be incoming to the machine at 1Gbps rates while being routed to the iDRAC7 at the slower 100Mbps This section describes this and other phenomenon that will impact performance which apply to these two cases but are not a factor when using the dedicated management port on rack and tower servers 1Gb auto 1Gb auto iDRAC7 client Switch blad Full duplex blade Virtual media data Figure 2 Speed difference on blades and in rack tower server shared mode Insight into TCP protocol TCP transmission control protocol provides different mechanisms for acknowledgement and retries of network packets Fundamentally using Virtual Media as an example packets sent from the management station client in Figure 2 are acknowledged by the receiver iDRAC7 with a network packet that reflects the next sequence number expected TCP specifies the retransmission of lost packets by one of two mechanisms fast retransmissions or retransmissions after a timeout The former occurs when the sender detects duplicate ACKs in which the next sequence number expected is the same as a previous acknowledgement This can only happen if the receiver observes a packet arriving out of order the acknowledgements will continue to contain the sequence number expected in the packet that was missed or dropped In this case the sender resends lost data without delay and throughput is not severely impacted However in case the sender is waiting on an ackno
6. h other NICs in the system such as those in general PCI Express slots this is because inbound traffic on teamed NICs can arrive on any port including the NICs to which the iDRAC7 does not have network controller side band connectivity Failover for iDRAC7 is supported with the LOM device ports Dedicated and shared network ports cannot be used simultaneously and dynamic failover between the dedicated NIC port and LOM ports is not supported A user can manually modify the active port setting locally using the F2 System Setup menu or remotely using RACADM or the Web interface Remote server management sessions such as virtual KVM virtual media telnet and SSH accessed using shared network ports are robust during normal server operations however momentary loss of remote connectivity is possible during particular server events that affect the external link Non session based server management traffic such as IPMI commands could be affected during momentary link losses Examples of the server events that can cause link loss include server power on and off warm reboot link failover UEFI network driver load and operating system network card device driver load or unload o In a network configuration with a single network switch the number of times the session is lost due to system events is small this number increases with more complex network topologies or when using 10 gigabit Ethernet ports that may exhibit longer link negotiation times O
7. iDRAC7 Networking and Improved Remote Access Performance This paper describes how TCP throughput impacts the performance of virtual media and other remote access features in various iDRAC7 networking configurations Andy Butcher and Tim Lambert Enterprise Solutions Group This document is for informational purposes only and may contain typographical errors and technical inaccuracies The content is provided as is without express or implied warranties of any kind 2012 Dell Inc All rights reserved Dell and its affiliates cannot be responsible for errors or omissions in typography or photography Dell the Dell logo and PowerEdge are trademarks of Dell Inc Intel and Xeon are registered trademarks of Intel Corporation in the U S and other countries Microsoft Windows and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell disclaims proprietary interest in the marks and names of others March 2012 Rev 2 0 2 iDRAC7 Networking and Virtual Media Performance Contents HAOGUC EOIN AEA AA caters NAA N AE AAN ENE AANA AEA A A AA A E sees 5 IBRA C7 NGEW OPI ING aaar A E 5 OVEN IOW ease E E E ENE EE E T 5 Dedicated Network Interface ssessesceesceeseesceescreccesceesoreceesoeesceeceeeoe 6 Shared Netwo
8. maximum transmission unit 1500 bytes to the network stack For example the application can send 64Kbytes and without intervention from the CPU the NIC will break this up into MTU packets for transmission on the wire While having the intended advantage of CPU offload when used in environments as illustrated in Figure 2 this can create fast bursts of data filling the switch or network device buffers en route to iDRAC7 By disabling this setting there is artificial throttling on the client machine that brings the data rate down to a level that can be handled without packet loss by the 100Mbps pipe at the end of the network to the iDRAC7 endpoint Note that this does not work in every case and is highly dependent on the client machine and its CPU load Minimize bandwidth consumed by Virtual Console The typical usage of Virtual Media includes concurrent usage of the iDRAC7 Virtual Console vVKVM virtual keyboard video and mouse There are two ways to minimize the network bandwidth consumed by the Virtual Console session and in turn leave more bandwidth available for the Virtual Media TCP stream First virtual media can be launched without the virtual console For example in the iDRAC7 Web interface if the Virtual Console is disabled and the user elects to launch the console he will be prompted to invoke only the Virtual Media application There is also a command line utility VMCLI documented in the iDRAC7 User Manual that allows you to use Vi
9. n network switches when spanning tree protocol is enabled and portfast disabled link down times will be significantly increased on shared network ports o Most of these specific server events result in a momentary interruption in service that may be noticeable to the remote user such as a pause in the virtual KVM video In rare cases where a session loss occurs re launching that feature may be required If session loss is observed and precludes intended server management operations then it is recommended to use the dedicated NIC or perform functions locally on the server To help mitigate the effect of a pause in the virtual KVM video features are available such as Video Boot Capture under the troubleshooting tab of the iDRAC7 Web interface o Further resilience to reduce or eliminate the effects of shared network port link interruptions following specific server events may be achieved by not iDRAC7 Networking and Virtual Media Performance explicitly interacting with the console mouse or keyboard during the interruption If possible on the client s OS modifying the client system registry to increase the number of TCP data retransmissions can help Influence of Networking Environment on Throughput The iDRAC7 SoC and firmware are not solely responsible for determining the achievable throughput instead it is the endpoint in a larger network with a number of devices in between it and the management station Figure 2 illustrates that tra
10. operates at 100Mbps for compatibility with the previous generation chassis 5 iDRAC7 Networking and Virtual Media Performance Dell PowerEdge 12 Generation X86 CPU Host Server Server In band Traffic lt _ n Band Trattic gt lt Server Management Traffic N U _ oO x LLI O A Network Controller IDRAC7 sideband Interface Shared Dedicated l Network Gigabit NIC Portis always Blade Servers The dedicated Failover and Teaming present on rack NIC is accessed via the Chassis Supported on Multiple Ports tower 600 900 Management Controller and uses series Enabled a 100Mbps full duplex port on LAN on motherboard can with iDRAC7 iIDRAC7 The 1GbE interface is l l Enterprise only available on Towers and Rack consist of multiple vendors License mount servers devices and I O fabric types Figure 1 Server Management Network Options Dedicated Network Interface Dell PowerEdge servers offer a dedicated management Ethernet port for communicating with iDRAC7 to provide various server management functions The dedicated NIC is useful to customers who commonly provide physical network isolation between their management network and other networks such as those utilizing the main system LOMs LAN on motherboard The 12 generation server 600 models and above such as the R620 and R720 always include the iDRAC7 dedicated management port hardware In previous generations
11. r iDRAC7 As a result the management network is relying on TCP to control the flow of data to iDRAC7 There are two built in mechanisms help with this first the receiver defines a window size that signifies to the sender the amount of data it is prepared to receive This size is communicated in the acknowledgment packets and the sender will not attempt to send more data than the endpoint receiver can handle Second the transmitter tracks a transmission window size that is determined by computing the minimum of the observed receiver window and its own varying size based on its congestion avoidance algorithm the latter is affected by whether or not it is observing missing acknowledgements However neither of these mechanisms alone will protect against possible dropped packets in the network switches Effect of dropped packets Dropped packets alone do not necessarily make performance slow however there is an impact when the client is doing retransmissions due to packet timeouts As illustrated in Figure 3 retransmission timeouts can cause brief interruptions in data streams and therefore slow down overall throughput The timeouts occurred in this example when the network switch in the blade chassis dropped packets because it could not keep up with the incoming data rate The throughput kept up but it was not ideal because of the breaks in the transmission while the sender was waiting for an acknowledgement that never came for a packet that wa
12. reating experimental firmware images 14 iDRAC7 Networking and Virtual Media Performance DELL
13. rk ports In either configuration the iDRAC7 MAC address is available by default on the front external server pullout tag or internally on a motherboard label or using the front LCD if equipped and the F2 System Setup Menu gt iDRAC7 Settings gt Network Menu The shared network port NIC can be configured locally using the Boot F2 Setup gt iDRAC7 Settings gt Network Menu or using RACADM or the Web GUI In addition the LOM or integrated network card can be disabled from the host server while still usable for only server management purposes this is configured using the Boot F2 Setup gt Integrated Devices menu If the LOMs are set to disabled and 7 iDRAC7 Networking and Virtual Media Performance the dedicated NIC is used by the iDRAC7 then the LOMs are put into their lowest possible power state Limitations of Shared Network Ports 8 When the server has AC input power applied but is powered off LOMs typically negotiate down the external link speed for reduced power consumption while still supporting Wake on LAN and or shared network ports These re negotiations can create a momentary external link loss which may or may not interrupt any active remote management connectivity If a connected switch is configured in a way to not allow for this dynamic speed negotiation then remote management connectivity may not be available when the server is powered down Shared network port use does not support teaming or failover of LOMs wit
14. rk Ports cesccsccesceccceccescevccescesceeccesceecceccesceeceescesceess 7 Benefits of Shared Network Ports cescecccesceccceccescenccescescceccesceeces 7 Limitations of Shared Network Ports cccceccccccecceccecccecceeceeceecceeces 8 Influence of Networking Environment on Throughput cceccecceccceccecceecees 9 Moigne nto TOP Drol OCO earranan ETET 9 Effectof dropped packets cacscacesneccnsunnsncessouacehcebarenesannnsersetanseaseseuenes as 10 UIS O a a a E E E E A EE EEE 11 Avoid Duplex mismatch sssessesseesoescessocesoesceesoreseesceesoeeceeeceesereoe 12 TO0MDps configuration cesrsrerrresikirreritinr irinn NEA 12 Disabling large send offload sssessesssesossseesceesoreceesceesoreceesoeeseseee 12 Minimize bandwidth consumed by Virtual Console cceeceeccecceecees 12 12G Speeds and RESUS gancoccssacceecosestesasonseuedsssCedessesGenuecwesedeesusecencceseeus 13 COM TUTON erana E EEE EE NETO EAR ORE TER EONA 14 3 iDRAC7 Networking and Virtual Media Performance Executive summary There are variables that can affect the performance of iDRAC7 remote management features This paper will explore some of those variables and help Dell customers achieve optimal performance from their iDRAC7 Understanding networking protocols such as TCP and the iDRAC7 s position in the network aids customers in this process As an example of a systems management application Virtual Media is a licensed
15. rtual Media without the remote desktop Second in the Virtual Console session there is a pull down menu titled Performance that allows the user to select a tradeoff between video quality determined by color depth and frame rate vs speed selecting a preference for maximum speed will reduce the 12 iDRAC7 Networking and Virtual Media Performance necessary bandwidth for the desktop display leaving more available for the Virtual Media TCP stream 12G Speeds and Results Dell tested a wide variety of client machines management stations and operating systems with the PowerEdge product line Table 1 represents a small sample of the results it is not intended to be exhaustive but rather demonstrate the achievable speeds The baseline CD speed for reference is 150Kbytes per second or 1 2 Mbps so 10X would represent 12Mbps Note that although the iDRAC7 CPU processing efficiency is not the subject of this paper decryption can have a significant impact on the throughput Therefore the user of Virtual Media should make an informed decision whether encryption is necessary in their application or if significantly increased throughput is more advantageous Managed Server Management Client Encryption Dedicated Shared Speed X CD a es a oe R720 Rack Windows 7 64 bit Disabled Dedicated 52 6X a a a R720 Rack Windows7 64 bit Enabled Dedicated 20 5X A pagaen O O R620 Rack Windows7 64 bit Enabled Shared 17 1X Java plug in M
16. s dropped 10 iDRAC7 Networking and Virtual Media Performance Sequence number E Time Sequence Graph 60000000 50000000 40000000 30000000 20000000 10000000 Time s Figure 3 Illustration of retransmission timeouts during a TCP stream Suggestions There are several things that can be done to maximize network throughput to iDRAC7 on rack and tower servers First using the dedicated 1Gbps port that comes with the iDRAC7 Enterprise license will provide an uninterrupted 1Gbps Ethernet pipe for management traffic Second as is documented in previous and current iDRAC7 user manuals either disable spanning tree protocol STP on the managed switch connected to the server or enable the portfast setting to avoid unnecessarily long interruptions in network traffic for ports that are connected to endpoints rather than other switches In the past it has been possible to modify windows registry settings to affect TCP stack parameters such as retransmission timeouts these are not included in these suggestions because they are not available on all operating system versions When not possible to use a dedicated management network with the 1GbE port there are some additional recommendations offered here for use if applicable in the IT environment 11 iDRAC7 Networking and Virtual Media Performance Avoid Duplex mismatch The need for half duplex during the advent of computer networks has created a present day phenomenon that can h
17. ssues commands to the administrator s client machine that are translated from the SCSI commands from the main processor and used to read the storage device in return the client machine returns data to the iDRAC7 TCP protocol is used to provide a mechanism for any lost packets to be retransmitted There are several interfaces for Virtual Media that could represent a choke point the USB link to the main processor the iDRAC7 network interface the server network interface to the external switch any switch interface along the way and the client NIC interface to its accompanying switch iIDRAC7 Networking Overview The Dell PowerEdge 12 generation server products offer several enhancements to the iDRAC7 server management networking options these enhancements provide improved connectivity flexibility performance and resilience options as well as reduced cabling and switch port management effort Figure 1 illustrates three of the possibilities for the iDRAC7 network interface they are configured with F10 during server boot or with the iDRAC7 Web interface or with the RACADM command line utility e The dedicated management port which is enabled with the iDRAC7 Enterprise license has improved to support gigabit Ethernet e A shared network port provides the capability to directly manage the server using the iDRAC7 through ports on the LAN on Motherboard LOM e A dedicated management port for the iDRAC7 is used for blade servers It
18. such as on the R610 and R710 the dedicated NIC port was an optional iDRAC6 Enterprise module On the R620 and R720 servers the iDRAC7 Enterprise software license available at the time of sale or later enables the dedicated management port functionality along with additional features such as Virtual KVM and Virtual Media 6 iDRAC7 Networking and Virtual Media Performance Additionally the dedicated NIC increases from 10Mbps or 100Mbps to gigabit capable Gigabit capability helps administrators minimize or avoid any special configuration of gigabit switches The dedicated NIC provides remote access while the server is powered on or off and also supports IPv4 IPv6 auto negotiation forced speed and duplex static IP and DHCP The network settings can be configured locally via the F2 System Setup Menu gt iDRAC7 Settings gt Network Menu or using RACADM or the iDRAC7 Web interface Shared Network Ports 12th generation servers such as the R620 and R720 continue to support shared network port functionality Shared network ports provide a network path through the LOMs to communicate with the iDRAC7 this communication is available for remote management when the server is on or off and all enabled server management features are supported Benefits of Shared Network Ports Since management traffic can be combined with host server traffic on the same physical cable s fewer physical network cables are required which helps with server cable m
19. wledgement that it never receives it will wait for a timeout period 250 ms might be typical and then try to resend the lost data either of these cases is possible if there are dropped packets 9 iDRAC7 Networking and Virtual Media Performance DeAL Turning to the switch behavior in the network packets are received on the inbound port and routed to the correct outbound port based on the address in the packet header In Figure 2 the switch or network card sending packets to iDRAC7 will sooner or later fill its internal buffers because the data on the 1GbE network is coming in faster than it can be sent out the sender does not necessarily wait for every acknowledgement before sending the next packet The network device buffer management effectiveness varies from one device to another Flow control using PAUSE packets specified by IEEE 802 3x is one obvious option for avoiding dropped packets However this is not universally enabled in network devices Also pause packets will be sent based on a watermark defined for the port s receive buffer and if used will halt all traffic coming into that port regardless of the destination if one end device is being throttled it will affect the performance of all end devices serviced by that switch Also in the case of the server LOM shared mode the cards are designed to give priority to the server networking traffic and will not halt these streams to avoid dropped packets for the management controlle
Download Pdf Manuals
Related Search
Related Contents
au通信サービスご利用にあたって Model 871 User Manual - North East Sportsplex Appendixes M68MPB16Z3 MCU PERSONALITY BOARD USER`S MANUAL Beverage Center and Wine Chiller 3. uso della gettoniera esterna 仕様書 PDF - テムテック研究所 STROKE AND BALE COUNTER - Allied Systems Company Copyright © All rights reserved.
Failed to retrieve file