Home
DCM310-A2 .pub
Contents
1. from hazardous live conductors is permitted X Do not discard this product or a throw away Maintenance Do not attempt to repair this Clamp Meter It contains no user serviceable parts Repair or serving should only be performed by qualified personal Cleaning Periodically wipe the case with a dry cloth and detergent do not use abrasives or solvents ACA 200A A CAT II 600V with respect to earth for the jaw Tactile barrier for Hand Guard lt _ A Do not hold the meter in front of 1 I 0 Current Cancel Battery Replacement the Tactile Barrier ACA 400A A CAT II 600V with respect to earth for the jaw Tactile barrier for Hand Guard A Do not hold the meter in front of 1 I 0 Current Cancel Specifications 1 1 General Specifications LCD display digits 2000 digit large scale LCD readout Measuring rate 2 5 times sec Overrange display OL is displayed for 20A and 200A range shows the real value when bigger than 400A range Low battery indicator ex is displayed Replace the battery when the indicator es appears in the display Power requirement 9V PP3 6LR61 battery Battery type and life ALKALINE 580 hours Rechargeable batteries are not suitable for use with this instrument the Tactile Barrier 1 2 Environmental Conditions Indoor Use Calibration One year calibration cycle Operating tempe
2. Megger DCM310 Clampmeter User Guide DCM310 CLAMPMETER DATA HOLD Power On Off ACA 20A N A Read First A Safety Information To ensure safe operation and service of the Meter follow these instructions Failure to observe warnings can result in severe injury or death Avoid working alone so assistance can be rendered To enhance safety test leads should be disconnected from instrument when not in use Do not use test leads or the Clamp Meter if they look damaged Do not use the Meter if the Clamp __ Meter is not operating properly or if it is wet Use the Clamp Meter only as specified in the Instruction card or the protection provided by the Clamp Meter might be impaired Special precautions are necessary when operating in situations where ee live parts at dangerous voltages may be encountered Personal protective equipment not supplied with this instrument should be used Symbols as marked on the A CAT III 600V with respect to earth for the jaw Tactile barrier for Hand Guard q A Do not hold the meter in front of the Tactile Barrier ci WEN Tester and Instruction card 10y 1 I 0 a Current Cancel Risk of electric shock See instruction card Equipment protected by double or El reinforced ifsulaton r Data Hold MAX Hold Battery 100A T CE Conforms to EU directives Application around and removal
3. rature 0 C 30 C lt 80 RH 30 C 40 C lt 75 RH 40 C 50 C lt 45 RH Storage temperature 20 to 60 C 0 to 80 RH batteries not fitted Operating altitude 2000m 6562 ft Overvoltage category IEC 61010 1 600V CAT II CAT III equipment is designed to protect against the transients in the equipment in fixed installations such as distribution panels feeders and short branch circuits and lighting systems in large buildings Conductor Size 27mm diameter Pollution degree 2 EMC EN 61326 1 Shock vibration Sinusoidal vibration per MIL T 28800E 5 55 Hz 3g maximum Dimensions W x H x D 56mm x 180mm x 32mm Weight 250g including battery Accessories Battery installed Carrying case and User manual 1 3 Electrical Specifications Accuracy is reading number of digits at 23 C 5 C lt 80 RH Temperature coefficient 0 2 x Specified accuracy C lt 18 gt 28 C AC Current Function Range Accuracy 0 19 99A 3 0 0 05 A An 20 00 199 9A 2 0 0 5 A 50 60Hz 20T 03 a 200 400A 2 0 5 A Limited Warranty This Meter is warranted to the original purchaser against defects in material and workmanship for 1 year from the date of purchase During this warranty period manufacturer will at its option replace or repair the defective unit subject to verification of the defect or malfunction This warran
4. ty does not cover disposable batteries or damage from abuse neglect accident unauthorized repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expense or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you Megger Limited Archcliffe Road Dover CT17 9EN United Kingdom Tel 44 0 1304 502100 Valley Forge Corporate Centre 2621 Van Buren Avenue Norristown PA 19403 USA Tel 1 979 690 7925 Email sales megger com Web www megger com
Download Pdf Manuals
Related Search
Related Contents
SDHC memory card with embedded wireless ダウンロード(PDF 632 KB) KS-AR8004D / KS Zanussi ZBC 748 User's Manual Le site - mode d`emploi Xtreme 17910 Samsung WF-R1056R 用户手册 Digitus DA-70577 storage enclosure Kit Manual LiBRA Control System USER MANUAL Copyright © All rights reserved.
Failed to retrieve file