Home
USER`S MANUAL - DAVI Y CIA, S.L.
Contents
1. oplite USER S MANUAL MA12 02 A 09 12 2010 DAVIS CIA www davicia com INDEX EN NOR 09 10 DESCRIPTION PART LIST STARTING UP LOCATION AND ENVIRONMENT OPERATION POLARIZATION OF THE CAMERA MAINTENANCE AND CLEANING 7 1 Equipment disposal TECHNICAL SPECIFICATIONS 8 1 Camera GUARANTEE CE DECLARATION OF CONFORMITY Q O MD HS OOWONAAAMN NH HW 1 DESCRIPTION 1 Sebum stick 2 Camera 3 Power supli connection 4 On Off switch 5 Camera connection 6 USB connection to the PC 2 PART LIST Camera x1 Sebum stick x1 MN IN Power adaptor 12VDC x1 USB cable x1 Software and User s manual de 01 ie Sebum sponges x100 User s manual 3 STARTING UP o Connect the equipment to the power supply 3 Connect the camera to the equipment 5 o Connect the equipment to the PC 6 Remember to connect always the equipment to the same USB port of the PC If you change the port the camera may not work o Incase that the dplite equipment has the touchscreen PC accessory connect the equipment s USB in the PC port indicated as CAMARA o Switch on the equipment 4 O 4 LOCATION AND ENVIRONMENT The appliance should be kept well away from vibrations and sources of intense heat such as heaters Stand the appliance on a flat level surface where it is firmly supported 5 OPERATION o Please refer to the software manual 6 POLARIZATION OF
2. THE CAMERA The dermoprime system uses a single device of integrated lenses that can explore 3 different skin layers thanks to the X60 Triple mode lens with automatic polarization These three images of the same area have been captured with the three modes of the X60 lens A e i LE A a Len a me TA ji ay ee aa Th O F jrs 4 LA FAA ae AA ral ate NORMAL 1 NORMAL 2 POLARIZED Analyzes Analyzes Analyzes e PORES e WRINKLES e SPOTS e UNIFORMITY e ELASTICITY 7 MAINTENANCE AND CLEANING Never attempt to carry out any repairs yourself In the event of a fault contact the Technical Assistance Service If the power cord is damaged it must be replaced by the Technical Assistance Service or qualified personnel in order to prevent any malfunction and make sure that the appliance is not dangerous Use only a soft slightly damp cloth to clean the appliance Never use petrol thinner or any other similar solvent product To prevent any damage never clean the camera lens 7 1 EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out w
3. heeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment 8 TECHNICAL SPECIFICATIONS DPLITE Manufacturer DAVI amp CIA C Murcia 35 nave G E08830 Sant Boi de Llobregat Barcelona SPAIN EC applicable Directives Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC 8 1 CAMERA 470 000 1 0Vp p Composite 75ohm USB 2 0 X1 Lens X60 triple Lens X10 Lens Disinfection with UV Lamp 9 GUARANTEE We provide a 1 year guarantee from the date of purchase The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation It excludes all removable parts such as batteries wires power supply devices etc Faults falling within the guarantee period shall be rectified free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recommended to keep the or
4. iginal packaging Following expiry of the guarantee period all services requested will be dealt with by our specialist technicians at the user s expense 10 CE DECLARATION OF CONFORMITY CE DECLARATION OF CONFORMITY FABRICANTE PRODUCTO DAVI amp CIA S L PRODUCT MANUFACTURER DIRECCI N C Murcia 35 Nave G ADDRESS Pol gono Industrial Can Calder n E08830 Sant Boi de Llobregat BARCELONA ESPANA DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Marca DERMOPRIME Brand Nombre dplite Name Tipo EQUIPO ELECTRONICO Type Electronic equipment Finalidad Prevista Equipo analizador de piel Intended Use Skin analyzer equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagn tica Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tensi n Low Voltaje Directive FECHA 04 de Septiembre de 2010 DATE 04 September 2010 Nombre J Masana Name Firmado Cargo Function DAVI amp CIA 10 DAVIS CIA C Murcia 35 Nave G Pol industrial Can Calder n E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 34 93 654 16 62 info davicia com www davicia com 11
Download Pdf Manuals
Related Search
Related Contents
SolaSpot Pro CMY User Manual [554 861] Tube à rayons X, Mo 閲覧する(PDF 8.75MB) - 桧家オーナーズクラブ CoMET 5.14 User Guide fx-82_85_350EX - Support - SkyLark 全文 - 裁判所 Formularios telemáticos Manual de usuario Trabajo Especial Copyright © All rights reserved.