1.     ITEM 5 When    TESTING    Light goes out  remove Test Gold   Read LED Display of Karat Value  Clean Test Gold thoroughly with  soft paper towel  Thoroughly wipe the Test Solution from the Test  Well using a paper towel followed by a Q Tip  If re testing is  desired  see    DO   S  amp  DON    TS     items    8    and    11        ITEM 6 Check to be sure that there is not excessive air in the bottle  and that the cap is tightened firmly     PRECAUTIONS   e After testing Gold item  it should be cleaned with a buffing wheel   However  it must be cleaned with the gray eraser before any new  test because of the residue left on the Gold from the previous test    e Improper of insufficient cleaning of the test Gold before testing can  increase the karat value readings    e Your unit is operating correctly if occasionally you do get a  reading in the next range  This can happen when the karat value of  the Gold you are testing is very close to the odd karat value  1 e   17K  19K  etc  Your unit is operating correctly when this occurs  and indicates the Gold you are testing is very near the in between  value    e The excess air must be squeezed out of the test solution bottle  between tests or when stored  Squeezing out the excess air keeps  the solution fresh  When all of the air cannot be squeezed out it  needs to be replaced  In any case  the bottle must be replaced 6  months after first opening     Un fresh    test solution can cause the  karat readings to go lower by one rang
2.   DON   TS     item 5   Attach Alligator Clip to Test Gold away from immersible  area     ITEM 2 Loosen the cap of the Test Solution and have a soft paper towel and some Q   TIPS handy     ITEM3 Press    TEST YELLOW GOLD    or    TEST WHITE GOLD     to match the type  of Gold that you are testing  and within two seconds  put three or more drops of Test  Solution into the Test Well  Quickly squeeze all of the air out of the Test Solution Bottle  and tighten cap firmly   See    item 6        ITEM 4 Observe that one of the Karat Value Lights is on  Any Karat Light may be lit   this is determined by a previous test or length of time that the unit has been off  After the  Light goes out   within one second   carefully immerse enough of the Test Gold into the  liquid to start the    Testing    Light being careful not to touch the reference Gold at the  bottom of the Test Well and being careful not to touch the Alligator Clip to the liquid   Hold the Test Gold without moving it until    TESTING    Light goes off  This will take 2  to 15 seconds  depending on the Karat value of the Test Gold  User should brace the     heel    of his hand on the unit or on the same surface as the unit rests on  When possible   brace the Test Gold on the inside of the Test Well just under the surface of the liquid and  be very careful not to touch the Reference Gold at the bottom of the Test Well    It is important that the Test Gold not be moved about in the Test Solution until a reading  is obtained 
3.  when the test is  complete or changing chemical solution use one end of the Q Tip to absorb the chemical   then use the other end to remove any remaining residue  Dispose of the Q Tip when  complete  Never leave any chemical solution in the well when not testing  If any chemical  happens to come in contact with the clip  clean immediately with a clean paper towel        10       When the    Low Battery    indicator flashes  it is necessary to replace the battery before  operating the unit  Simply remove the 4 small screws located under the rubber feet on the  rear of the Gold Tester  Carefully remove the rear cover  Locate the 9 Volt Battery and  replace with a new one  Replace the rear cover  being very careful not to pinch the wire  leads with the cover  Replace 4 rubber feet     TROUBLE SHOOTING GUIDE    PROBLEM CAUSE SOLUTION    e    Yellow Gold    or    White Gold    light    Replace Battery  does not light     e Low battery light is flashing     e The testing light does not flash e Clean test Gold in area to be tested   e Alligator clip not connected to test Gold     e Reference Gold coated  See note at end of  document     e 24 Karat indication for all tests  e Test Gold removed before testing light  goes out   e Test Gold or clip being shorted to  Reference Gold at bottom of Well     e Misread on high Karats  e Temperature not within 65  F to 90  F     NOT GOLD reading for all tests  e Alligator clip in liquid during test           SERVICE    Before returning unit fo
4. RS MIZAR  INC     THE GOLD TEST EXPERTS  M24 OWNERS MANUAL    IMPORTANT WARNING     BEFORE USING  PROFESSIONAL MODEL M24  READ ALL INSTRUCTIONS  AND SAFETY DATA AT THE END OF THE DOCUMENT     This manual covers the operation of the M24 Electronic  Gold Tester    RS MIZAR  INC  has been issued two Patents for its  development on the M24 full range Gold Tester  This new process  gives accurate and non destructive test results all the way to 24K  gold  It can help determine Gold Karat value in as little as 2 seconds     This process can distinguish non gold and gold plate from true    Karat  Gold    without the destructive Fire Assay testing  which would change  the value of the jewelry     RS Mizar now brings you the fastest and easiest Gold Analyzer for all  the trades where jewelry and    Karat Gold    have to be quickly and  accurately evaluated     The M24 Gold Tester  U S  PATENTS 5080766  5128016    OTHER U S  AND INTERNATIONAL PATENT RIGHTS PENDING    Nov 1999    SPECIFICATIONS    M24 GOLD TESTER  M24 Range  9  10  12  14  16  18  20  22  and 24 Karat    Automatic Shutoff after each test  Approximately 14 seconds    Test times  2 seconds from 9 14 Karats  2 15 seconds from 16 24 Karats    Delay before beginning test  12 seconds   Display time  12 seconds   Gold colors  Yellow  White  Red  Green  see    Gold Composition      Non destructive testing   Distinguishes Gold Wash and Flash from Solid Gold     Can be used    to distinguish Gold Plate from Solid Gold  see    Test
5. ck Gold plate     GENERAL DESCRIPTION OF PROCEDURE    To determine that an item is Gold plated    non Gold     the user of the M24  Gold Tester must take at least two different readings  one reading of a surface   which has not been erased or filed  The reading of the erased or filed surface will  be lower if the metal underneath is not gold   To be sure the metal underneath is  not Palladium  see the section on    TESTING FOR PALLADIUM       The M24 Gold  Tester will read as    NOT GOLD    if a sufficient area of non Gold is exposed to the  liquid but the un erased or un filed Gold plate exposed to the liquid does have some  effect on the reading  this is why point 2 of the following section under     PRECAUTIONS    is important     When testing for heavy Gold plate  it may be necessary to use a fast drying lacquer  or material such as a clear fingernail polish  The area to be tested must be coated  with the lacquer and allowed to dry  Next  make a file mark in the center of the  coating deep enough to expose the base metal  Then test the exposed base metal  with the M24 Gold Tester  Do not allow the Testing Solution to touch any part of  the Gold that has not been coated     PRECAUTIONS    1  When testing the un erased or un filed portion  be sure that the test area has  been relatively unaffected by wear  Flat or thin Gold plated items will tend to  be worn at the edges  If it is difficult not to expose a worn area when testing  an un erased or un filed area  the user may 
6. clip lead  simply hold the clip  lead lightly against the Test Gold during test    8  Do always clean the Test Gold with the Gray Eraser before retesting in the same  location  Pink eraser can be used but it requires considerably more pressure and effort  for accurate readings    9  Do replace the Testing Solution every 6 months after opening    10 Do use only within Operating Temperature 65  F 90  F     NOTES  1  In the event the Alligator Clip contacts the testing solution  the Alligator  Clip must be rinsed thoroughly with water and dried before using again   2  WARNING  Eye Hazard    Read warning label on bottle of Test Solution   3  IMPORTANT  The Testing solution is sensitive to exposure to air  Minimize the time  cap is loose on bottle     TESTING FOR GOLD PLATE    INTRODUCTION   Probably most of the Gold plated items referred to as    costume jewelry    or     fashion jewelry    contain Gold at the surface  which is no thicker than eight  millionths of an inch  Such a Gold plate is referred to as Gold flash  A large  percentage of Gold flash is sufficiently thin and or porous  microscopically  that the  M24 Gold Tester will    read through    the plate and indicate    NOT GOLD     A  thicker plate will read as Karat Gold unless a portion of the surface being tested is  erased with the eraser pencil or filed to expose the metal underneath  The eraser  should be used as first choice since it is easier to use and non destructive  However   the eraser will not work on thi
7. e  You should always have a  fresh bottle of test solution available  Record here the date the  bottle was opened     DO   S  amp  DON   TS    1  Don   t use Testing Solution for more than one test  errors will result    2  Don   t touch Test Gold or Alligator Clip lead to Reference Gold at bottom of Test Well   If this happens remove liquid and re do test procedure    3  Don   t let Alligator Clip touch liquid    4  Don   t leave liquid in test well  This will void your warranty    5  Do clean Test Gold before testing if it isn   t bright and shiny  Unclean Gold may result  in inaccurate readings    6  Do keep Gold chains very tight  link to link  during testing  Use the fewest number of  links  one if possible  between the Alligator Clip lead and the Gold link to be  immersed in to the liquid  Three problems can exist with testing chains    a  There may be dirt or contamination between links that would require intensive  cleaning  i e  ultrasonic  before testing    b  Some chains  especially certain European manufactured chains have a thin non   metallic coating that must be removed from an area before testing  The eraser pencil  may be used to remove this coating    c  When testing chains  remember that the solder often used at the link s  is of a  lower Karat than the rest of the chain  Therefore  avoid testing in that area    7  Do make sure good contact is achieved between the Test Gold and the Alligator Clip  lead  If the object to be tested is too large to fit in the 
8. edure    will impart confidence to the point  that the user will find testing for Gold plate to be fast and easy     GOLD COMPOSITION    There are four basic colors of Gold     IB      ON COW erties em oes at tera Ne ose ot ate most common  Daye  NV IEG ste ns ge basnsek stacey otek es este NEA second most  common   3  Red Pink ROSE aeea apni nonce bes uncommon   2 EE 0 ea Re a RR ori er eet oe we emeetre Mente very uncommon    The colors are obtained by the use of two or more varied quantities of base  metals  These base metals are Silver  Copper  Zinc  and Nickel     Not only are there four basic colors but each color can and does vary the  percentages of the base metals  As such  there is no specific formula for each  color of Gold  This makes for a range of readings in each color plus a  variation of each color at any specific Karat mixture     The M24 Gold Tester can distinguish between Karats of the two popular  colors  Yellow and White  by means of color selector buttons  Most red color  Gold can be determined by using the White range selector button  Most green  color Gold can be determined by using the Yellow range selector button   There are no ranges that are compatible for use on dental Gold alloys     CAUTION  The M24 Gold Tester is a highly accurate  precision instrument  for determining Gold Karat values  However  should any disagreement arise  with its use  it is recommended that confirmation be obtained with a Fire Assay  examination process  This devise  alt
9. hough highly accurate  should be used as  a guide to Gold Karat values  The exactness of the device depends on  adherence to the instructions provided in this manual and the knowledge of the  base metal alloys which are involved     TESTING FOR PLATINUM    Platinum is indicated when the test item reads 22K or higher  That is because white Gold  above 18K is virtually non existent     TESTING FOR PALLADIUM    Both Palladium and Platinum will indicate Karat Gold if tested  Platinum jewelry is  usually traded at a higher price than Gold jewelry  so Platinum is seldom marked as Gold   Palladium  however  is one quarter to one third the price of pure Gold  so it should be  noted that pure Palladium may read as medium Karat Gold  Palladium prong settings are  sometimes soldered into diamond solitaire White Gold rings  If Palladium is suspected  it  is easily distinguished from Gold as nitric acid will quickly turn Palladium dark  Gold is  not affected in this way     TABLE OF STANDARDS    Karat Decimal Gold Gold   Part Per 1000  24K 1 000 100 0 1000  22K 917 91 7 917  20K 833 83 3 833  18K  750 75 0 750  16K  667 66 7 667  14K  583 58 3 583  12K  500 50 0 500  10K 417 41 7 417  9K 375 37 5 375    MAINTENANCE OF THE M24    The most important step to consistently have accurate results using your gold tester  is the  cleaning of the     Well  amp  Clip     Also included with your unit is a standard    Q Tip      which is to be used for the cleaning of the well  Do your test as normal 
10. ing for Gold  Plate        Dimensions    EnS eaa N 6 3     Wide S nested E E ENES 4 0     Depiiikessrasa e T Ls     Weisht  With  Baer ose cha Miesidestuaschetheldeeivessuand 8 0 oz     Operating Temperature  65   F to 90   F  19   C to 32   C   Battery  One  1  standard 9 Volt    CONTENTS OF PACKAGE    1  M24 ELECTRONIC GOLD TESTER  2  ERASER   3  TESTING SOLUTION  No  1995    4  OWNERS    MANUAL   5  ERASER PENCIL    OPERATING INSTRUCTIONS    OPERATING INSTRUCTIONS FOR TESTING GOLD FROM  20K TO 24K   When testing Gold from 9K tol8K  go directly to instructions below  for 9 to 18 Karat testing  When testing Gold from 20K to 24K  a  buildup of test solution on the Reference Gold will have to be  removed to obtain the proper results     STEP A   Sharpen the Pencil Eraser and then cut off the end with a sharp knife or razor  so that it is flat and round  about  160    or 5 32      Then place the eraser into the Test Well  and firmly rotate back and forth for about four seconds  Then brush debris from the Test  Well  This preparation will eliminate the excess buildup on the Reference Gold  For all  tests of 20K to 24K Gold do this step of removing excess buildup on the Reference Gold  with the sharpened and blade cut Pencil Eraser  A dirty Eraser tip will not sufficiently  clean Test Well     STEP B   Go to    item 1    below   OPERATING INSTRUCTIONS FOR TESTING GOLD FROM 9K TO 18K     ITEM 1 Thoroughly clean immersible area of Test Gold with the Gray Eraser  see     DO   S  amp
11. r service or repairs  you MUST obtain a RETURN  MATERIAL AUTHORIZATION  RMA   An RMA may be obtained by  writing     TESTING SOLUTION  No  1995   Replacement of the Testing Solution and Cleaning Solution can be obtained  from your supplier or   Oris Nelson Enterprise  Inc   511 North Indian River Drive  Suite  A  Fort Pierce  FL 34950  772 429 0045    WARRANTY    R S MIZAR provides that each M24 Gold Tester System will be free from  defects in material and workmanship for a period of 2 years from the date of  purchase  This Warranty becomes void by     1  Unauthorized repair  misuse  modification  alteration  tampering or  breaking any factory seal     2  Accidental damage  neglect or improper use     3  Leaving Testing Solution in Test Well      Battery and solutions are not included in warranty    R S MIZAR  Inc  shall not be held legally liable or responsible for any error in    determining the Gold content of any object using the M24 Gold Tester        12       
12. wish to selectively mask any area in  question with fast drying lacquer  The reason for masking a worn surface is  that if you test a worn surface first  you may obtain the lower Karat reading  before any erasing or filing has been accomplished  You  therefore  may not  get a lower Karat value on your second test and not be able to determine that  you are testing Gold plate     2  When testing the erased or filed portion  be sure that enough of the surface  area immersed in the liquid is erased or filed down to expose the suspected     base metal    underneath     MORE DATA ON TESTING FOR GOLD PLATE    The vast majority of Gold plate is 22K or better  Most Gold plated jewelry is flash Gold  plate and most flash Gold plate is less than 5 millions of an inch  1 8 micron   The M24  Gold Tester will read right through the 22K Gold plate and indicate anywhere from not  Gold to 12 K Gold  Any time you get a 12K or lower reading  Gold plating should be  suspected  To determine Gold plate simply use the gray flat eraser on the test sight and  then inspect for the presence of base metal     In addition  inspect the Gold color of items reading 9 12 K Gold  If they are really 9 12  K they would not have that    rich    color of a 22K Gold plated item     FINAL POINT    It is strongly recommended that users of the M24 Gold Tester practice testing for Gold  plate on a few items believed or known to be Gold plated  A few sets of practice runs  described under    General Description of Proc
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
MEAC WEBSITE CONTENT ADMINISTRATION USER MANUAL  SeeTool - Solutions for KNX  パソコンの安全対策 - Microsoft  Philips myLiving  Declaration of conformity 61/2012  トロージャンUVマックス  新製品案内 - ヤマト自動車    Manuel d`utilisation WinEur Portfolio (titres)  Sandberg RJ45 on COM 9F, 1,8 m    Copyright © All rights reserved. 