1. closing with operator present 1 6 with DIP2B OFF N B any safety devices automatic closing and plug in cards in the AUX housing are disabled With DIP3B OFF permanent closing of the contact ena bles automatic closing Opening of the contact stops the closing operation With DIP6A ON connecting terminal 41 enables a safety edge test cycle before every operation If the test fails the SA LED flashes and the test is repeated 32 IP1851EN 2015 11 24 IP1851EN 2015 11 24 Command Function Description TRANSMITTER STORAGE AND CANCELLATION nm me Transmitter storage press the PRG key the SIG LED turns on proceed with transmission from the transmitter to be stored the SIG LED flashes wait 10 s for storage to be completed the SIG LED turns off Transmitter cancellation press the PRG key for 3 s the SIG LED flashes press the PRG key again for 3 s the SIG LED flashes faster an an 4 1 SOFAI SOFA2 or GOPAVRS self controlled safety edge SOFA1 SOFA2 GOPAV SAFETY STOP Connect the output contact of the device to termi nals 1 4 on the control panel in series with the photocell output contact if installed WARNING if not used make a jumper for ter minals 41 6 33 5 Sliding gates outputs and accessories Output Value Accessories Descrip
2. Set DIPAB OFF and DIP6B OFF Manually move the barrier bar and make sure it is correctly balanced Switch on and check the automation is operating correctly with the subsequent opening and closing commands Check that the limit switches are activated if used Connect the safety devices removing the relative jumpers and check they function correctly If desired adjust the automatic closing time with the TC trimmer WARNING the automatic closing time after a safety device has triggered depends on the DIP3A setting Set the desired opening and closing speed with the VA and VC trimmers WARNING with QIK automations for correct operation with a bar longer than 4 5 m adjust the VA and VC trimmers to no more than 5096 10 Connect any other accessories and check they are functioning Urn eminente 43 11 Troubleshooting The external safety devices are not activated Short circuited accessories POWER ALARM LED off Safety contacts are open SA LED on Safety contacts not correctly con nected or self controlled safety edge not functioning correctly flashing SA LED No storage module or incorrect storage module SA and POWER ALARM LEDs flashing alternatively Photocells activated SA LED on Incorrect connections between the photocells and the control panel There is a presence of friction Disconnect all accessories from terminals 0 1 a voltage of 24V must be present and reconnect them
3. ooog VA VC TC RI C NO 14 0 EGER 47 Closing limit switch Opening limit switch Closing limit switch Opening limit switch 15 Example of parallel automations S JRI 282 8 x 36513651 2 m 1 1421 2 4 In 5445544 JR1 JR1 LE A 1 5 9 1320 0 1 6 8 41 1 1 5 9 1320 016 8 41 A a E LL It is possible to command two automations A and B in parallel with the connections and settings indicated in the figure Step by step commands 1 5 and radio controls are like an opening command To manage both automations with a single remote control do not use the radio receivers on the control panels JRT OFF but insert a BIXLR22 radio receiver Adjust TC VA and VC trimmers in the same position on both control panels E opening and closing movements may not be synchronised 48 IP1851EN 2015 11 24 IP1851EN 2015 11 24 All the rights concerning this material are the exclusive proper
4. one at a time Check that the safety contacts are closed correctly NC Check connections to terminals 6 8 on control panel and connections to the self controlled safety edge Switch the automation off and plug in the correct storage module Check that the photocells are clean and operating correctly Connect NC safety contacts to gether in series and remove any jumpers on the control panel terminal board Check the DIP5B setting Manually check that the automa tion moves freely and check the R1 adjustment 44 IP1851EN 2015 11 24 IP1851EN 2015 11 24 45 Substitute the transmitter batter ies 12 Application example for sliding gates When using the control panel for sliding automation applica tions Select the correct opening direction with DIP2A Example 1 When using the control panel for sliding gate ap plications connect the opening and clos ing limit switch NC contacts to terminals 0 11 12 if required With this configuration the wing stops when the limit switches are B 1 am DIPIA ON Menang A1 Wara US VC TC RI Closing limit switch 1 Opening limit switch 01 1 5 9 1320 0 1 6 8 41 activated TT Example 2 The remote control B can be used w
5. 6A F2A F1 6A Motor output 24 V 8A 24 V 9 5 24 14A 24 V 7 24 V 0 3 24 V 0 3 A 24 V 0 3 A 24 V 03 A power supply Temperature min 20 C min 20 C min 20 C min 20 C P max 55 C max 55 C max 55 C max 55 C 240 IP24D IP24D IP24D protection Radiofrequency 433 92 MHz 433 92 MHz 433 92 MHz 433 92 MHz Storable trans 100 100 100 mitters 200 BIXMR2 200 BIXMR2 200 BIXMR2 ol in NE IP1851EN 2015 11 24 31 4 Commands Function Description STEP BY STEP WITH AUTOMATIC CLOSING OPENING WITH AUTOMATIC CLOSING CLOSING REVERSAL SAFETY CONTACT OPERATOR PRESENT CONTROL AUTOMATIC CLOSING CLOSING LIMIT SWITCH SAFETY TEST With DIP1A OFF and TC lt MAX closing of the contact activates an opening or closing operation in the following sequence opening stop closing opening N B the stop is not permanent but has the duration set with the TC trimmer With DIPTA ON and TC MAX closing of the contact activates an opening operation With DIP2B OFF closing of the contact activates a clos ing operation Opening the safety contact triggers a reversal of the movement reopening during the closing operation Opening of contact 1 9 enables the operator present function opening with operator present 1 5 with DIP1A ON and
6. ENTREMATIC Ditec EL31R 1851 IN 11 mm BATK3 SA power 12 EB D Safety switch Transformer VA VC TC RI Limit switch Limit switch 69 4 4 lt 56 501228 2431 Power supply L 5 88 ngog Oo 5 Ei S959 2 0 PE 2 E L 9 EF 8 ca o oO 8 A 5 lt 2 oO www ditecentrematic com C LL SLO 3188141 28 IP1851EN 2015 11 24 Index LX EC declaration of conformity 31 3 1 Applications 31 Self controlled safety edge 33 Barriers outputs and accessories 35 Trimmers 36 Barriers dip switches 38 7 5 Signals 39 9 Working modes for sliding gates 41 0304 Sliding gates start up 42 Troubleshooting 44 13 Application example for barriers 47 048 Application example for parallel automations 29 1 General safety precautions Failure to observe the information in this manual may result in minor personal injury or damage to eguipment Save these instructions for future reference This installation manual is intended for qualified personnel only Installation electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance
7. automatic detection point of the opening and closing o The current stored profile shows into consideration 5 by selecting DIP6B ON the control panel activates system for the current necessary to move the automation at any peration he forces necessary for correct movement taking the frictions The current profile is automatically updated every time an operation is completed opening closing and it gradually adapts to the fric ions resulting from progressive and natural ageing of the gate frame reducing the need to service N B The current profile is kept s ored even in the event of a power failure 41 10 Start up 101 Starting the sliding gates 1 Make a jumper for NC safety contacts 2 Check that the storage module corresponding to the type of application selected is correctly plugged in 3 Adjust the opening and closing stop limit switches if any N B limit switches must be kept pressed until the operation has been completed 4 Set TC MAX and R1 50 Select the desired opening direction with DIP2A Set DIPAB OFF and DIP6B OFF 5 Manually move the sliding gate and make sure the entire stroke slides evenly and without friction 6 Switch on and check the automation is operating correctly with the subsequent opening and closing commands Check that the limit switches are activated if used 7 Connect the safety devices removing the relative jumpers and check they function cor
8. ct electric block DIP6A Safety test terminal 41 Disabled Enabled Reversal safety contact opera With automation stopped and With automation stopped and tion contact 1 8 open opening op 1 8 open all operations are erations are permitted disabled Preflashing for 3 seconds be Disabled Enabled fore closing after intervention of safety switch 1 8 DIP8B Electronic antifreeze system Enabled Disabled Maintains motor efficiency even at low ambient temperatures 38 IP1851EN 2015 11 24 IP1851EN 2015 11 24 74 Jumper Disabled Enabled 75 Signals Power supply on Encoder not working or DIP5B se lection is not consistent with the encoder actu ally being or not being there eee c 5e e e C Shortcircuiting of flashing light driver At least one of the safety contacts is open e e e e Safety test failure terminal 41 1 9 contact is open DIP6A selection is not consistent with the con nection of terminals 6 8 0 11 limit switch contact is open Transmitter enabling storage phase Radio transmission of a stored remote control received Radio transmission of an unstored remote control received Damaged storage 39 8 Radio ANT The control panel is eguipped with a radio receiver with a freguency of 433 92 MHz dai The antenna consists of a rigid wire 173 mm ong connected to the ANT cla
9. e CH2 partial opening command it causes the automation to open for about 1 m e CH3 command to switch on off the courtesy light e CH4 stop command equivalent impulsive command 1 9 Transmitter cancellation Hold down the PRG key for 3 s the SIG LED starts to flash To cancel all the remote controls from the memory press the PRG key again keeping it pressed for 3 s To cancel single remote control press any one of the previously memorised keys of the remote control to be cancelled The cancellation is confirmed by the guick flashing of the SIG LED For further information see the user manual for GOL series remote controls If the control panel is replaced the storage module being used can be inserted in the new control panel For tutter information see the user manual or GOL series remote conois 77 B 40 IP1851EN 2015 11 24 IP1851EN 2015 11 24 9 Working modes for sliding gates The control panel can work in the following 3 modes e automations with encoder DIP5B ONJ and without stop limit switches the automation stops on the mechanical stops e automations with encoder DIP5B ON and with stop limit switches the automation stops after the stop limit switches have tripped e automations without encoder DIP5B OFF and with stop limit switches the automation stops after the stop limit switches have tripped In the automations with encoder an innovative
10. e motorisation declines all responsibility in the event of component A parts being fitted that are not compatible with the safe and correct operation Use original spare parts only for repairs or replacements of products 11 Installation precautions Fix the control panel permanently Pass the cables along the lower side of the container If they are accessible block the cables with cable glands not supplied Keep the line and motor conductors separated from the command conductors by at least 8mm in the terminal boards connection points e g using straps Connect together the protection conductors yellow green of the line and the motors using the clamp supplied At the end of the installation close the container 30 IP1851EN 2015 11 24 2 EC Declaration of Conformity The manufacturer skrona Sweden declares that the directives Entrematic Group AB with headguarters in Lodjursgatan 10 SE 261 44 Land EL31R type control panel complies with the conditions of the following EC Directive 2004 108 EC Low Voltage Directive 2006 95 EC R amp TTE Directive 1 Landskrona 29 01 999 5 2013 Marco Pi 7 Pos Vee 3 Technical specifications ALTA5EH ALTA7EH CROSS3E 555 557 555 1 CROSS7EH1 3M1CR5 3M1CR7 3M1QK AR 3M1CR5C5 3M1CR7C5 3M1QKC7 Power supply 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz F1 fuse F1 6A F1
11. e must be inserted and removed with he power supply disconnected Barrier operation The batteries are kept charged when the power supply is on If the power supply is off the panel is powered by the batteries until the HA BATK3 power is re establish or until the ba ery voltage drops below the BAT 2x12 V 2Ah safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries B the operating temperature of the rechargeable batteries is approximately 5 40 Automation status lamp proportiona The light goes off when the autornation is closed 24V 3 W The light comes on when the automation is open The light flashes with variable freguency while the automation is operating Flashing light WITH DIP5A OFF it is activated during the opening and closing LAMPH operations 24 N 25 W External courtesy light With DIPSA OFF a courtesy light can be connected in series to the NO contact which activates for 180 s on each opening total or partial 230 V 400 W step by step and closing command lt gt LN WARNING use a double insulated cable Flashing light WITH DIPSA ON it is activated during the opening and closing LAMPH operations 24 25 W P1851EN 2015 11 24 35 Output Accessories Description o lt o lt Electric block With DIP5A 0N it is activated wit
12. h the barrier closed QIKAFE 24 V 300 mA max 7 Settings 71 Trimmers VA Opening speed adjustment Adjusts the opening speed VC Closing speed adjustment Adjusts the closing speed TC With DIP3B OFF permanent closing of contact 1 20 enables automatic clos ing MIN 0 s MAX 120 s Adjustment of power and stop distance It adjusts the power of the automation With DIP7B OFF it adjusts the closing bar stop distance 36 IP1851EN 2015 11 24 IP1851EN 2015 11 24 7 2 Sliding gates dip switches Command functions 1 5 Step by step Opening N B it also sets operating on the AUX plug in card DIPSA Automatic closing time restore 508 100 Preflashing for 3 seconds Disabled during opening Enabled for both opening and Enabled only with automatic closing closing with TC 3 s DIP1B Reversal safety contact opera With automation stopped and With automation stopped and contact 1 8 open opening op 1 8 open all operations are erations are permitted disabled DIP3B Command functions 1 20 Partial opening command DIP5B Encoder selection Automation without encoder Automation with encoder N B stop limit switches must be installed 37 73 Barrier dip switches Command functions 1 5 Step by step Opening N B it also sets operating on the AUX plug in card DIP5A Operating of output 0 14 and Flashing light and courtesy light Flashing light lighting kit and C NO conta
13. ing Flashing light The flashing light activates simultaneously with the opening and LAMPH closing operation 24 25 W Internal courtesy light A courtesy light that turns on for 180 seconds with every opening total LUXK3E n LUXK7 or partial step by step and closing command can be connected in 230 V 60 W series to the NO contact External courtesy light An external courtesy light that turns on for 180 seconds with every LN 230 V 400 W opening total or partial step by step and closing command can be connected AN WARNING use a double insulated cable 34 IP1851EN 2015 11 24 6 Barrier outputs and accessories Output Value Accessories Description Accessories power supply 0 1 24 03 Power supply output for external accessories including automa H H H H F tion status lamps The control panel is fitted with a housing for a plug in card such as radio receivers magnetic loops etc AUX Operating of the plug in card is selected by DIP1A WARNING the plug in cards must be inserted and removed with he power supply disconnected The storage module allows remote controls to be stored and the ype of control panel application to be defined see TECHNICAL ai STORAGE SPECIFICATIONS on page 4 MODULE the control panel is replaced the storage module being used can be inserted in the new control panel WARNING the storage modul
14. ith step by step 01522204 ON JA functioning and at the same time DIPTASOFF J Ge les terminal 5 with opening function by 1211 0 making the connections indicated and setting DIPTA OFF gt lt Closing limit switch 1 Opening limit switch o po poang 0 1 6 841 Opening Partial opening as IP1851EN 2015 11 24 46 IP1851EN 2015 11 24 13 Application example for barriers When using the control panel for barrier applications Select the correct opening direc tion with DIP2A Connect the opening and closing limit switch NC contacts to termi nals 0 11 12 With this configuration the barrier stops when the limit switches are activated 7 DIPIA ON Luc mel Uwe VA VC TC RI 12111 alee panig 01684 2 1 14 Operator present function modes Quando il quadro elettronico viene usato in modalit uomo presente scollegare il morsetto 9 impostare il senso di marcia mediante DIP2A OFF In questa condizione i comandi di apertura 1 5 e di chiusura 1 6 funzionano solo se mantenuti pre muti al loro rilascio l automazione si ferma La chiusura automatica e i comandi radio sono disabilitati B alli AETEI el 50 50 lt MAX
15. mp pond t is possible to increase the range of the radio by connecting the antenna of the D lashing lights or by installing the tuned 10s BIXAL antenna To connect the external antenna to he control panel use a coaxial cable type RG58 max 10 m Check that the storage module is inserted in the COM connector Up to 100 remote controls can be stored in the storage module WARNING if the radio receiver on the control panel is not used set JR1 0FF and remove the storage module Transmitter storage Press the key on the radio receiver or on the control panel the SIG indicator LED lights up Proceed with transmission by pressing the CH keys on the remote control that you want to store within the range of the radio receiver The remote control is now stored During this phase the SIG indicator LED flashes When the SIG LED comes on again you can validate another remote control Validate all the new remote controls by making a transmission as indicated You automatically exit the procedure 10 seconds after the last transmission or you can press the PRG key again the SIG LED goes off Up to four CH keys of a single remote control can be stored If only one any CH key of the remote control is stored command 1 5 step by step opening is carried out If 2 4 CH keys of a single remote control are stored the functions matched with the CH keys are as follows e CH1 command 1 5 step by step opening
16. rectly 8 If desired adjust the automatic closing time with the TC trimmer WARNING the automatic closing time after a safety device has triggered depends on the DIP3A setting 9 Setthe desired opening and closing speed with the VA and VC trimmers 10 Connect any other accessories and check they are functioning 11 Set the obstacle thrust with the R1 trimmer To enable the current profile see chapter 9 proceed as indicated set DIP6B ON any previously stored current profile is reset e perform 2 complete operations opening closing 12 For correct operating of the sliding gate with the correct operating forces we recommend using the following settings gate without rubber edges DIP4B ON and DIP7B ON gate with rubber edges DIPAB ON and DIP7B OFF gate with self controlled safety edges DIPAB OFF and DIP7B OFF WARNING After adjusting check that the working forces exerted by the door wings comply with standards EN12453 EN12445 i vmm eminentes 42 IP1851EN 2015 11 24 IP1851EN 2015 11 24 10 2 Starting the barriers A 25 2 5 6 7 8 Make a jumper for NC safety contacts Check that the storage module corresponding to the type of application selected is correctly plugged in Adjust the opening and closing stop limit switches if any N B limit switches must be kept pressed until the operation has been completed Set TC MAX and R1 50 Select the desired opening direction with DIP2A
17. tion Accessories power supply 0 1 24 Vz03A Power supply output for external accessories including automa H H H H E tion status lamps The control panel is fitted with a housing for a plug in card such as radio receivers magnetic loops etc AUX eT Operating of the plug in card is selected by DIP1A WARNING the plug in cards must be inserted and removed with the power supply disconnected The storage module allows remote controls to be stored and the type of control panel application to be defined see TECHNICAL ORADE the storage module being used can MODULE be inserted in the new control panel WARNING the storage module must be inserted and removed with the power supply disconnected Barrier operation The batteries are kept charged when the power supply is on If the power supply is off the panel is powered by the batteries until the HH BATK3 power is re establish or until the battery voltage drops below the BAT 2x12 V 2Ah safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries N B the operating temperature of the rechargeable batteries is approximately 5 40 Automation status light proportional The light goes off when the automation is closed 24 V3 W The light comes on when the automation is open The light flashes with a variable freguency while the automation is operat
18. ty of Entrematic Group AB Although the contents of this publication have been drawn upwith the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publica tion We reserve the right to make changes without prior notice Copying scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB 49 P1851EN 2015 11 24 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com ENTREMATIC
19. with the present standards Read the instructions carefully before installing the product Bad installation could be dangerous 425 The packaging materials plastic polystyrene etc should not be discarded in the environ ce ment or left within reach of children as these are a potential source of danger Before installing the product make sure it is in perfect condition Do not install the product in explosive areas and atmospheres the presence of inflammable gas or fumes represents a Serious Safety hazard The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the automation Before connecting the power supply make sure the plate data correspond to that of the mains power supply An omnipolar disconnection switch with minimum contact gaps of 3mm must be included in the mains supply Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a Suitable overcurrent cutout When requested connect the automation to an effective earthing system that complies with current safety standards During installation maintenance and repair operations cut off the power supply before opening the cover to access the electrical parts The electronic parts must be handled using earthed antistatic conductive arms The manufacturer of th