VCL-SafeComm 16 E1 Links (48 E1 Ports)

image

Contents

1. 10W Operations and Maintenance OAM Interfaces e RS232 serial interface for local terminal access e USB serial interfaces for local terminal access e 10 100BaseT Ethernet Interface for remote access over an IP network Command Language e Command Line Interface English text commands Orion Telecom Networks Inc 2012 14 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Compliance Regulatory e EMC FCC Part 15 Class 2 e Safety UL 1459 Issue 2 e Operation ETS 300 019 Class 3 2 e Storage ETS 300 019 Class 1 2 e Transportation ETS 300 019 Class 2 3 Management and Monitoring e RS232 serial USB serial interfaces for local terminal access e 10 100BaseT Ethernet Interface for remote access over an IP network e Telnet Remote access over IP links e SNMP Traps and NMS for real time remote monitoring and management over an IP network e Automatic Link Test feature link testing at user programmable periodical intervals e Visual I O status LED Display NMS with Telnet XPort Specification Network interface RJ 45 Ethernet 10BaseT or 100BaseT TX auto sensing Compatibility Ethernet Version 2 0 IEEE802 3 Protocols supported ARP UDP IP TCP IP Telnet ICMP SNMP LEDs 10Base T and 100Base TX Activity Full half duplex Management SNMP Serial login Telnet login EMI Compliance Radiated and conducted emissions complies with Class B limits of E
2. Technical specifications are subject to changes without notice Windows is the registered Trademark of Microsoft Corporation USA Revision 10 January 24 2014 Headquarters Phoenix Arizona Regional Office Miami Florida Orion Telecom Networks Inc Orion Telecom Networks Inc 20100 N51st Ave Suite B240 4000 Ponce de Leon Blvd Suite 470 Glendale AZ 85308 Coral Gables FL 33146 U S A Phone 1 480 816 8672 Phone 1 305 777 0419 Fax 1 480 816 0115 Fax 1 305 777 0201 E mail sales Qoriontelecom com E mail sales oriontelecom com Website http www oriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2012 14 12
3. Telecom Networks Inc 2012 14 8 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Technical Specifications Network Interface Number of Interfaces 16 Equipment E1 Links E1s 16 Telco Main E Links for Equipment A 16 Telco Standby E1 Links for Equipment B Line Rate E1 2 048 Mbps Line Code HDB3 Frame Structure G 704 Jitter Tolerance As per ITU T G 823 Output Jitter lt 0 05 Ul in the frequency range of 20 Hz to 100 KHz Nominal Line Impedance 120 Ohms Balanced RJ 45 Pulse Mask As per ITU CCITT Rec G 703 Loss and recovery of frame alignment As per clause 3 of ITU CCITT G 732 Loss and recovery of multiframe alignment As per clause 5 2 of ITU CCITT G 732 AC Power Supply Specifications Output voltage of AC Adapter 100 240 Volt AC Range of input AC voltage 100 V to 240 V AC 50Hz 60Hz System Input voltage 7 5 V DC to 9 0 V DC DC input polarity protection Maximum full load output current 2 5 at 7 5 V DC 9 0 V DC Input voltage reversal protection Provided in the Card Efficiency at full load gt 86 DC Power Supply Specifications Input DC voltage Dual Input 48V DC nominal Range of input voltage 18V to 72V DC System voltage 3 3V Input voltage reversal protection Provided in the Card Short circuit protection Provided Power Consumption lt
4. e Windows based GUI Graphical User Interface for easy configuration management and access Ability to monitor multiple units from a single NMS OAM Operation and Management Ports e RS232 Serial Port e USB COM Port e 10 100BaseT Ethernet for remote access Orion Telecom Networks Inc 2012 14 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Mode of Operation There are three modes in which the VCL SafeComm E1 1 1 Automatic Protection Switch can be configured to operate in 1 AUTOMATIC SWITCHING MODE 2 EXTERNAL TRIGGER SWITCHING MODE 3 MANUAL SWITCHING MODE AUTOMATIC SWITCHING MODE The VCL SafeComm can be configured to operate in an AUTOMATIC SWITCHING MODE In the automatic mode the switch shall automatically switch and re route the E1 circuits from the MAIN route to the STANDBY route if there is an AIS or a LOS LOSS OF SIGNAL alarm on the MAIN E1 link route Similarly in the automatic mode the switch shall automatically switch back and re route the E1 circuits from the STANDBY route to the MAIN route upon the restoration of the service on the MAIN E1 link route All switching parameters and link restoration parameters are user programmable EXTERNAL TRIGGER SWITCHING MODE Sometimes the user wants to switch the E1 circuits between the MAIN route and the STANDBY route when some external event occurs In the EXTERNAL TRIGGER MODE the user can switch between the MAIN E1 route and the STANDBY E1 rou
5. 00 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 3 VCL 1431 APS 16 48E1 2DC024 VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 24V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 4 VCL 1431 APS 16 48E1 2DC048 VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 48V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 5 VCL 1430 APS 16 48E1 EXT 1AC220 VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 1 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set Orion Telecom Networks In
6. 1 1 Automatic Protection Switching Equipment the product may be used to improve network reliability and control Traffic Protection Alternate Facility Advantages Service Differentiation Agreements Increased Network Reliability Resilience Media and Path Diversity Remote Management Alarm logging and monitoring Benefits Competitive Service Level Back haul Network Technology Migration User Programmable 1 1 Protection Parameters Loss Of Signal LOS Alarm Indication Signal AIS External open close dry contact signal User programmable criterion for switching between Active and Standby E1 Links at the customers premises Loss of E1 Signal LOS The Loss of Signal condition in a E1 may occur due to e The failure of the E1 Port of the customer premises equipment e Or due to loss of power to the customer premises equipment e Or due to the disconnection of the E1 Cable between the protection e Switch and the E1 Port of the customer premises equipment Alarm Indication Signal This Alarm indicates that a E1 link error has occured AIS External Dry Contacts This indicates the External Dry Contacts open close state Signal Orion Telecom Networks Inc 2012 14 5 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Security and Password Features System Access Control and Management Options e Telnet e CLI Control Interface HyperTerminal or Vt100 e SNMP V2 Traps MIB File provided
7. N55022 1998 Direct and Indirect ESD complies with EN55024 1998 RF Electromagnetic Field Immunity complies with EN55024 1998 Electrical Fast Transient Burst Immunity complies with EN55024 1998 Power Frequency Magnetic Field Immunity complies with EN55024 1998 RF Common Mode Conducted Susceptibility complies with EN55024 1998 Mechanical Specifications Rack mounting Standard 19 Inch DIN Rack Height 44 00 mm Depth 260 00 mm Width 477 00 mm Weight 4 3 Kg Temperature Operating 0 C to 50 C Humidity 5 to 95 Non Condensing Orion Telecom Networks Inc 2012 14 10 VCL SafeComm 16 E1 Links 48 Et Ports 1 1 APS Ordering Information S No PartNo ProductDescription 1 VCL 1430 APS 16 48E1 1AC220 VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 1 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 2 VCL 1430 APS 16 48E1 2AC220 VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic Protection Switching APS Equipment 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 1
8. TELECOM NETWORKS ORION TELECOM NETWORKS INC VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 Automatic Protection Switch Product Brochure amp Data Sheet Headquarters Phoenix Arizona Orion Telecom Networks Inc 20100 N51stAve Suite B240 Glendale AZ 85308 Phone 1 480 816 8672 Fax 1 480 816 0115 E mail sales oriontelecom com Website http www oriontelecom com Regional Office Miami Florida Orion Telecom Networks Inc 4000 Ponce de Leon Blvd Suite 470 Coral Gables FL 33146 U S A Phone 1 305 777 0419 Fax 1 305 777 0201 E mail sales Qoriontelecom com Website http www oriontelecom com Orion Telecom Networks Inc 2012 14 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Product Description The VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 Automatic Protection Switching Equipment may be used to protect upto 16 E1 Links 48 E1 Ports point to point links and provide an alternate communication route to each E1 Link between any two E1 points In the event of the failure of the primary Main E1 communication VCL SafeComm 16 E1 Links 48 E1 Ports route the VCL SafeComm 16 Et Links 1 1 1 1 Automatic Protection Switching APS Automatic Protection Switching Equipment automatically switches the E1 traffic to a secondary standby E1 route The VCL SafeComm 16 E1 1 1 Automatic Protection Switching equipment is available in a 2U high chassis which may be mounted in any DIN
9. c 2012 14 11 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Ordering Information S No PartNo ProductDescription 6 VCL 1430 APS 16 48E1 EXT VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic 2AC220 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 100 240V AC Power Supply Input Adapter Option 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 7 VCL 1430 APS 16 48E1 EXT VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic 2DC024 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 48 x E1 Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 24V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set 8 VCL 1430 APS 16 48E1 EXT VCL SafeComm 16E1 Links 48E1 Ports 1 1 Automatic 2DC048 Protection Switching APS Equipment with External Trigger 19 Shelf 2U High Rack Mount Version Supports upto 48 x E Port 120 RJ45F 16 for Main E1 16 for Primary E1 16 for Secondary E1 2 x 48V DC Power Supply Input 1 x System Core Cables Installation Documentation System User Manual System User Manual Disk etc Set
10. ion to the primary optical fiber E1 Link The switching time and restoration criterion is user programmable Orion Telecom Networks Inc 2012 14 2 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Application Diagram Figure application 1 Microwave Microwave System System E1 E1 SafeComm 16 E1 Links 48 E1 Ports SafeComm 16 E1 Links 48 E1 Ports Upto 16 E1s Upto 16 E1s Fiber E Point to Point Application May be used in a point to point configuration to provide 1 1 Protected Alternate Routing Path between any two points using diverse or similar E1 transmission mediums Figure application 2 TYPICAL STAR CONFIGURATION a5 1 1 Redundant Link et 7 AX MW MW MW 4 LINK LINK LINK Co Point to Multipoint Application To provide 1 1 Redundant E1 Link s between a single BSC location and multiple BTS locations using diverse or similar E1 transmission mediums Orion Telecom Networks Inc 2012 14 3 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Figure application 3 Central Site 16 Eis 16 Els il 16 E1 APS Protection Multiplexer Application to provide resilient protected E 1 rings over PDH networks The VCL SafeComm may also be used in 1 1 redundant protected E1 rings on PDH networks using diverse or similar E1
11. standard 19 Inch rack This product allows the user to design 1 1 protected redundant E1 routes on similar fiber fiber or complementing fiber radio transmission mediums The criterion for switching between the primary main and the secondary protected standby routes is user programmable Criterion for switching between the primary main and the secondary protected standby routes may be Loss Of Signal on E1 links or AIS All Ones AIS alarm condition The criterion for switching time and recovery time between the primary main and the secondary protected standby routes is user programmable Data transported on the E1 Links is transparent and protocol independent Applications Providing 1 1 alternate paths between any two E1 Transmission mediums active standby E g e Fiber Fiber e Radio Fiber e Radio HDSL e Fiber HDSL etc Example The user may deploy the VCL SafeComm 16 E1 1 1 Automatic Protection Switching Equipment to provide an alternate communication route between an optical fiber link and a radio link between any two points In the event of the failure of the primary optical fiber link the E1 is automatically switched to the alternate route over the E1 radio thus ensuring maximum uptime on all such 1 1 protected E1 Links Once the primary optical fiber E1 Link on the optical fiber is restored the VCL SafeComm 16 E1 1 1 Automatic Protection Switching Equipment automatically restores the communicat
12. te when an external trigger such as an closed opened physical contact is applied to the switch This unique feature is used by certain radios equipment suppliers where they apply an external trigger to switch and re route the E1 circuits between their main E1 radios and standby E1 radios MANUAL SWITCHING MODE In Manual Switching Mode the user shall use manual Telnet commands to switch the E1 circuits between the MAIN route and the STANDBY route manually using Telnet commands In this mode the AUTOMATIC MODE and the EXTERNAL TRIGGER MODE are both disabled and the manual commands over ride all other modes Orion Telecom Networks Inc 2012 14 7 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Front View AC Version VCL SafeComm 16 E1 Links 48 E1 Ports Automatic Protection Switching APS EQUIPMENT TELCO TELCO MAIN LINE STANDBY LINE m 1 5 9 13 1 5 9 13 1 5 9 13 F4 CEET GE TRE Oo Di ag 4 8 12 16 4 8 12 16 4 8 B 12 16 OAM COMPORT te 7 5V DC L8 RESET DC Version VCL SafeComm 16 E1 Links 48 E1 Ports Automatic Protection Switching APS EQUIPMENT TELCO TELCO MAIN LINE STANDBY LINE Du 1 5 9 13 1 5 9 13 1 5 9 13 A i 2 6 am 10 fam 14 2 5 E 10 fam 14 2 6 IEI 10 fa 14 L sar A le ij 6 if 11 15 3 T i 15 3 T 11 15 L5 asvoc PWR asvoc PWR 4 si 8 E 12 BI 16 4 E s BI 12 BI 16 4 E 8 E 12 E 16 LES INPUT 1 INPUT 2 L8 RESET Orion
13. transmission mediums How ItWorks VCL SafeComm With Path Protection Switching During normal operation VCL SafeComm sends duplicate traffic across both the working and dedicated protection E1 facilities while continuously maintaining the performance of both links to determine which link shall be utilized Figure application 44 Working Link E1 Link Protection Link Duplicate l Mobile Switching Office l Remote Cell Site Orion Telecom Networks Inc 2012 14 4 VCL SafeComm 16 E1 Links 48 E1 Ports 1 1 APS Features amp Highlights High density protection switching equipment upto 16 E1 Links i e 48 E1 Ports To provide an independent point to point protected E1 Llink between two E1 USER PORTS on similar example fiber fiber or dissimilar fiber radio mediums To provide 1 1 E1 redundancy Remote system configuration and management interface through CLI text based commands using Telnet and GUI Graphical User Interface Provide 1 1 Protection Routing Path between BSC and BTS These ensure that mission critical voice data control and management traffic are properly supported and maintained even during E1 backhaul facility outages When the primary working link fails the E1 traffic is automatically switched to the standby secondary link to ensure maximum uptime Through the comprehensive remote configuration and alarm management capabilities of the VCL SafeComm 16 E1

Download Pdf Manuals

image

Related Search

Related Contents

Automated Immunohistochemical Staining-Bond  Mercedes-Benz 2006 SLR-Class Automobile User Manual  ILOG Solver 6.0 Release Notes  TEFAL WM753D12 Instruction Manual  2月15日号  The First Years B505C User's Manual  Digitus DB-230212  Palram 702563 Installation Guide    Dell Latitude C840 Quick Setup Guide  