Home
LB DVR User`s manual
Contents
1. Cancel Figure 7 41 Please refer to the following sheet for detailed information Parameter Function Event It includes local alarm network alarm Type Local alarm Device detects alarm from input port Network Device detects alarm from network You need to draw a circle here so that system can detect the alarm signal Type There are two options normal open and normal close NO becomes activated in low voltage NC becomes activated in high voltage Period Alarm record function becomes activated in the specified periods There are six periods in one day Please draw a circle to enable corresponding period Select date If you do not select current setup applies to today only You can select all week column to apply to the whole week Click OK button system goes back to alarm setup interface please click save button to exit Anti dither System only memorizes one event during the anti dither period The value ranges from 3 to 600s Normal Enable alarm activation function You need to select alarm output port Out so that system can activate corresponding alarm device when alarm occurred Alarm System can delay the alarm output for specified time after alarm message occurred Alarm System can upload the alarm signal to the centre Including alarm upload centre Record System auto activates current channel to record once alarm occurs working with alarm activation function Please note current
2. Figure 5 6 Cancel Figure 5 7 5 3 3 Schedule Please refer to chapter 4 4 schedule 5 3 4 RS232 RS232 interface is shown as below There are five items See Figure 5 8 Function There are various devices for you to select Console is for you to use the COM or mini end software to upgrade or debug the program The control keyboard is for you to control the device via the special keyboard Transparent COM adapter is to connect to the PC to transfer data directly Protocol COM is for card overlay function Network keyboard is for you to use the special keyboard to control the device PTZ matrix is to connect to the peripheral matrix control Baud rate You can select proper baud rate Data bit You can select proper data bit The value ranges from 5 to 8 Stop bit There are three values 1 1 5 2 Parity there are five choices none odd even space mark System default setup is Function Console Baud rate 115200 Data bit 8 Stop bit 1 Parity None After completing all the setups please click save button system goes back to the previous menu 86 3 RS232 X Function Console Baudrate 115200 Data Bits Stop Bits Parity Default Cancel Figure 5 8 5 3 5 Network Here is for you to input network information P Version There are two options IPv4 and IPv6 Right now system supports these two IP address format and you can access via them e MAC address The host in the LAN can get a uni
3. Figure 7 58 Mobile Setup 7 3 4 6 WIFI Config The WIFI interface is shown as in Figure 7 59 Configuration Control Panel H B QUERY SYSTEM INFO WIFI CONFIG Bf VERSION WIFI Enable Sire sN ssb Tveiptype Encyptpe Sic B LOG gt PE SYSTEM CONFIG mee ADVANCED ADDTIONAL FUNCTION CARD OVERLAY AUTO REGISTER 3G CONFIG M WIFI Working Current Hotspot IP Address Subnet Mask Default Gateway save Figure 7 59 WIFI Setup 7 4 Search Click search button you can see an interface is shown as in Figure 7 60 Please set record type record date window display mode and channel name 161 You can click the date on the right pane to select the date The green highlighted date is system current date and the blue highlighted date means it has record files 201212 A e 14 36 29 9 11 12 14 El S SS ms SS es A PE Xu gra gu y are gis m Figure 7 60 Then please click search button you can see the corresponding files in the list See Figure 7 61 A 2 soso 14 36 23 ul 10 11 12 22 23 24 fon ie ea gt E Ee ES Ee Ss A Es a E Eidos gire PES Figure 7 61 Select the file s you want to download and then click download button system pops up a dialogue box shown as in _ Figure 7 62 then you can specify file name and path to download the file s to your local pc 162 Save jn Ej Desktop My Computer My Documents l My Network Places Filename Save
4. Setto Read Write 7 Execute Type Read Write Status Normal Capacity 232 87 GB Record time 10 09 26 17 30 36 11 03 02 09 36 00 10 09 23 12 20 10 10 09 26 17 30 37 Figure 5 33 Please highlight icon O to select the corresponding function 101 B ABNORM OOOO O Disk Error gt w Cancel Figure 5 34 For the HDD group setup operation please note e Each channel s records can be stored into the specified HDD Group e Each HDD Group is corresponding to several hard disks while one hard disk is only included in one HDD Group e Each channel is only corresponding with one HDD Group while one HDD Group can store records from several channels e HDD Group is only available for read write HDD and self defined disks other types of hard disks cannot be set as HDD Group Important e e SATA also supports this function you can manage e SATA hard disk as local hard disk e Current series software version can only set the HDD group operation of the read write HDDs It is not for the redundancy HDD HDD Setting Click the button HDD Settings at the top right corner of the Figure 5 33 system will pop up an interface as below See Figure 5 35 The number of hard disk from 1 to 12 is shown in the HDD No column If there is a mark E in the front of the number it means this interface have access to the hard disk otherwise it does not have access to the hard disk The HDD Group column list
5. 54 4 Overview of Navigation and Controls Note All the operations listed below are based on the 2U series product Before operation please make sure e You have properly installed HDD and all the cable connections e The provided input power and the device power are matched e The external power shall be DC 12V e Always use the stable current if necessary UPS is a best alternative measure 4 1 Login Logout amp Main Menu 4 1 1 Login After system booted up system pops up the startup wizard Click the Cancel button you can go to the system login interface Click the Next Step button you can go to the startup wizard interface Here you can set the system basic information See Figure 4 1 Startup Wizard startup Wizard General Display Encode schedule Record Control NetWork k Startup Next Step Cancel Figure 4 1 The system login interface is shown as in Figure 4 2 System consists of four accounts Username admin Password admin administrator local and network Username 888888 Password 888888 administrator local only Username 666666 Passwords 666666 Lower authority user who can only monitor playback backup and etc e Username default Password default hidden user You can use USB mouse front panel remote control or keyboard to input About input method Click 123 to switch between numeral English character small capitalized and denotation Note For
6. Download Speed Oks There are max 100 files in one page Click here to view more Figure 4 20 68 4 6 Detect 4 5 1 Go to Detect Menu In the main menu from Setting to Detect you can see motion detect interface See Figure 4 21 There is three detection types motion detection video loss camera masking 4 5 2 Motion Detect Detection menu is shown as below See Figure 4 21 Event type from the dropdown list you can select motion detection type Chamnel select the channel to activate recording function once alarm occurred Please make sure you have set MD record in encode interface Main Menu gt Setting gt Schedule and schedule record in manual record interface Main Menu gt Advanced gt Manual Record Latch when motion detection complete system auto delays detecting for a specified time The value ranges from 10 300 Unit second Region Click select button the interface is shown as in Figure 4 22 Here you can set motion detection zone There are 396 PAL 330 NTSC small zones The green zone is current cursor position Grey zone is the motion detection zone Black zone is the disarmed zone You can click Fn button to switch between the arm mode and disarm mode In arm mode you can click the direction buttons to move the green rectangle to set the motion detection zone After you completed the setup please click ENTER button to exit current setup Do remember click save button to save current setup If you click ESC button
7. Function Pattern 1 Preset Patrol No l0 Patrol Pattern Left Border Right Figure 6 10 6 2 8 Activate Border Function In Figure 6 6 click auto scan button the system begins auto scan Correspondingly the auto scan button changes to stop button Click stop button to terminate scan operation 6 2 9 Flip In Figure 6 6 click page switch button you can see an interface is shown as below See _ Figure 6 11 Here you can set auxiliary function Click page switch button again system goes back to Figure 6 2 119 Direct Aux Oper Light Aux Num Oper 1 Page Switch Figure 6 11 120 7 WEB CLIENT OPERATION There might be slightly difference in the interface due to different series 7 1 Network Connection Before web client operation please check the following items e Network connection is right e DVR and PC network setup is right Please refer to network setup main menu gt setting gt network Use order ping DVR IP address to check connection is OK or not Usually the return TTL value should be less than 255 e Open the IE and then input DVR IP address e System can automatically download latest web control and the new version can overwrite the previous one e f you want to un install the web control please run uninstall webrec2 0 bat Or you can go to C Program Files webrec to remove single folder Please note before you un install please close all web pages otherwise
8. PPPoE name and PPPoE password you get from your ISP Internet service provider Click save button you need to restart to activate your configuration After rebooting DVR will connect to internet automatically The IP in the PPPoE is the DVR dynamic value You can access this IP to visit the unit a PPPOE User Name Password IP Address Cancel Figure 5 15 5 3 5 6 DDNS Setup DDNS setup interface is shown as in Figure 5 16 You need a PC of fixed IP in the internet and there is the DDNS software running in this PC In other words this PC is a DNS domain name server 91 In network DDNS please select DDNS type and highlight enable item Them please input your PPPoE name you get from you IPS and server IP PC with DDNS Click save button and then reboot system Click save button system prompts for rebooting to get all setup activated After rebooting open IE and input as below htto DDNS server IP virtual directory name webtest htm e g http 10 6 2 85 DVR _DDNS webtest htm Now you can open DDNSServer web search page Y DDNS DDNS Type Private DDNS MY Enable Server IP Port 30 Domain Name User Name Password Update Period 300 Default Cancel Figure 5 16 Please note NNDS type includes CN99 DDNS NO IP DDNS Private DDNS Dyndns DDNS and sysdns DDNS All the DDNS can be valid at the same time you can select as you requirement Private DDNS functio
9. 1024x768 Pa br Y Y 8 8 8 O Y Bl El E iE E E E E L tu Y El E3 4 800850100 L iE E E EELE He Ep View 1 rd _ i A Tin vt ha dl POUR ER BET erro 4 Vill ve Y er Y r HS VIC YY Y A fig O WI ite vik Yy 1 fi Wata Fait i sis PIMPLE I 27 NA Default Cancel r Ype Figure 5 28 In Figure 5 28 click modify button after channel You can see an interface is shown as in Figure 5 29 Please note all your modification here applies to local end only You need to refresh web or client end to get the latest channel name System max support 25 digital character Channel Name Default CAM 1 CAM 3 CAM 5 CAM 7 CAM 9 CAM 11 CAM 13 CAM 15 Figure 5 29 CAM 2 CAM 4 CAM 6 CAM 8 CAM 10 CAM 12 CAM 14 CAM 16 Cancel In tour mode you can see the following interface On the right corner right click mouse or click shift button you can control the tour There are two icons stands for enabling window switch and kc stands for disabling window function See ae 5 3 10 Default Figure 5 30 99 Click default icon system pops up a dialogue box You can highlight O to restore default factory setup See _ Figure 5 26 Select all General Encode Schedule RS232 Network Alarm Detect Pan tilt zoom Display Channel name Please highlight icon O to select the corresponding function After all the setups please click save button system goes back to the previous
10. 5 UNDERSTANDING OF MENU OPERATIONS AND CONTROLS 82 5 1 Menu TOS versidad ans 82 5 2 Mal Moni iia 82 5 3 A O A 83 Fk E A A Ia 83 A o A A O A 85 Doo DONA e re ey es O o te 86 DA Oe ea AEA E AE EA AE 86 ELE AN WOR aa a a E AOR a a a OE ST ER 87 BSGO E A II E O A NR 97 Sor A RIN E 98 5399 A Gorontalo bet ceria wes et sen nahin sata cata saeco road gal Saas a a NO 98 A aoaaa aa ea a ae 98 5 3 10 PEN Sse O east aoa Gace meat a oa tae EEEE E eae decane 99 1V 5 4 Seale A 100 5 5 NE A A A 100 SST DE O A A eer 101 Oe O A O A E E 104 ES O A O EO EOE Ne PT EN 105 5D Manual SC ONC AAA A abeeestete eae 105 O AG OMe sagen redeate cotinenc tes ecu e eas eens 105 550 a A EEA 108 Oe AS A A O A 108 o WICC O O A A A ele bwin elon eee ear teed 109 OD HAV SHAY cre AAA 109 5 5 10 So oe AAA Ay sala sesoa E EEA E 111 5 6 Nomad eaea aE R ii 112 A A SA 112 A gave IN A A CN 113 SGo o A E ee re an ee ee 113 504A A AE 114 SO OE T E aa a a NR a PONE Re PS 114 5 7 SOMO A o NO E eee rye eee 115 6 ABOUT AUXILIARY MENU cccccccccncoconcncncancnnnnoncnnnnoncnnanoncnnanannnnanannnnazanananzano 116 6 1 Goto Pan Till ZOOMUIM CN Ue hovedcccartecscceceldockaverescceccedeccevscwesecaed AS 116 61 14 3D Inteligent Positioning KV A TOA 116 6 2 Preset Patrol Pattern Border FUNCION iia 117 A 0 AAA e E O A In E TH 118 S2 ACA A a A SA 118 629 O En en 118 624 ACTIV ATS MO O ao add 118 6020 o A ts OEA E TER 118 626 ZACI
11. 960H series Main High performance industrial embedded micro controller System Processor Embedded LINUX System Multiplex operations Multiple channel record multiple channel Resources playback and network operation simultaneously User friendly graphical user interface Input Devices Front panel USB mouse remote control optional Function click USB mouse to switch screen Compression Video Standard H 264 Compression Compression 4 CH composite 8 CH composite video 16 CH composite video input input NTSC PAL video input NTSC PAL BNC BNC 1 0Vp p 750 NTSC PAL BNC 1 0Vp p 750 1 0Vp p 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output Video monitor 1 ch VGA output Video Output 1 ch HDMI output 1 ch matrix output Support TV VGA HDMI video output at the same time Video PAL 625 line 50f s NTSC 525 line 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s Record Speed per channel A lada dais Video Partition l windows Optional Video Input 19 Adjust TV output zone suitable to anamorphic video Channel Lock Cover secret channel with black screen though system is encoding normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection status are shown on the bottom left of display screen Hue brightness
12. Ea ADDTIONAL FUNCTION Figure 7 50 7 3 3 6 Snapshot Snapshot interface is shown as in Figure 7 51 155 E Control Panel no SNAPSHOT af Query System Info Channel Channel 0 Ef VERSION Ef HDD INFO Ef LOG 44 System Config Fame Bele 1F S GENERAL ENCODE Resolution CIF k SCHEDULE Rs232 Quality 60 NETWORK ALARM DETECT PANITILT ZOOM DEFAULT B4CKUP ADVANCED HOO MANAGEMENT ABHORMITY Alarm 110 Config Record ACCOUNT Snapshot mode Snapshot_Timing Enable AUTO MAINTENANCE ADDTIONAL FUNCTION DNS Save Refresh Figure 7 51 Please refer to the following sheet for detailed information Parameter Function Channel It is the monitor channel Snapshot mode There are two modes Timing and activation Frame rate You can select from the dropdown list The value ranges from 1f s to 7f s You can select from the dropdown list The 1 Channel 1 and the 9 channel support D1 HD1 BCIF CIF QCIF Channel 2 to channel 8 channel 10 to channel 16 supports CIF QCIF Note 960H series supports 960H D1 HD1 BCIF CIF QCIF Resolution You can select from the dropdown list Here is for you to set video quality There are six options 10 30 50 60 80 100 100 is the best quality Quality 7 3 3 7 Abnormity The abnormity interface is shown as below See Figure 7 52 156 Configuration ll Control Panel Bf Query System Info ABNORMITY df VERSION
13. English character P Q R S Play previous 0 In playback mode playback the previous video In text mode input number 0 In normal playback or pause mode click this button to reverse playback In reverse playback click this button to pause playback In text mode input number 6 English character M N O In playback mode playback the next video In menu setup go to down ward of the dropdown list In text mode input number 9 English character W X Y Z Reverse Pau se 6 Play Next 9 Play Pause 5 USB port Network abnormal indication light In normal playback click this button to pause playback In pause mode click this button to resume playback In text mode input number 5 English character J K L To connect USB storage device USB mouse Network error occurs or there is no network connection the light becomes red to alert you HDD HDD error occurs or HDD capacity is below specified threshold value the light becomes red to alert you System is recording or not It becomes on when system is recording It is to receive the signal from the remote control Alarm Here you can view there is external alarm input or not The indication Alarm light becomes on when there is an external alarm The light light become off when the external alarm stops abnormal Indication light Record light I Z z a4 O 2 1 2 1 5U series The front panel is shown as below See Figure 2 2 c650606050065006060600
14. _ lie v 7 3 2 6 Alarm a Status External Addr Internal Addr Port mapping list Searching 0 0 0 0 0 0 0 0 UPNP V UPNP Enable ServerName Protocol_ Intemalport Extemalport HTTP TCP UDP Add Mapping Delete TCP 80 TCP 37777 UDP 37778 Save Refresh Figure 7 39 UNPN Alarm setup interface is shown as in Figure 7 40 Please make sure you have connected the corresponding alarm output device such as the light buzzer and etc Configuration ll Control Panel Bf Query System Info Bf VERSION Ef HDD INFO Ef LOG F System Config GENERAL a ENCODE SCHEDULE R5232 NETWORK E3 ALARM DETECT PAN TILT ZOOM DEFAULT BACKUP ADVANCED HDD MANAGEMENT ABNORMALITY Ez Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE Matrix config ADDTIONAL FUNCTION ALARM Local larm Y Input v Y Normal Open Type Period V Alarm Out Latch iv Record Channel Record Latch V Send Email MV Tour Y PTZ Activation Y Capture lv MatrixEnable Set Anti dither 7 12 3 14 5 fO sec 17300 Y Alarm Upload T 2 3 4 5 6 7 0 0 10 10 12 19 19 151 fo sec 107300 F Show Message 1 2 3 4 5 6 7 e 9 10 19 12 13 14 15 16 72 3 4 5 6 7 9 9 10 5121 1415 18 m o sec 0600 Copy Save Refresh Figure 7 40 145 Channel Event Type 01 02 Never 03 Never 0 O4 Never
15. f HDD INFO Bf LOG Event Type No Disk viN 44 System Config Da GENERAL La ENCODE La SCHEDULE Da R5232 Da NETWORK ALARM DETECT PAN TILT ZOOM DEFAULT BACKUP w Normal Out 1 2 3 10 sec 107300 W Alarm Upload amp ADVANCED HDD MANAGEMENT Y Send Email Y Show Message E ABNORMITY Alarm I O Config Record ACCOUNT SNAPSHOT La AUTO MAINTENANCE 3 ADDTIONAL FUNCTION Refresh Figure 7 52 Please refer to the following sheet for detailed information Parameter Function Event Type Normal Out Send email Alarm upload Show message e The abnormal events include disk error no disk disconnection IP conflict MAC conflict and etc e You need to draw a circle to enable this function The corresponding alarm activation output channel when alarm occurs There are six channels The alarm output can delay for the specified time after alarm stops Then system disables alarm and corresponding activation output The value ranges from 10s to 300s If you enable this function system can send out email to alarm the specified user System can upload the alarm signal to the network includes the alarm centre System pops up the alarm messages in the monitor interface Once you check the box here the buzzer beeps when an alarm occurred 7 3 3 8 Preview Control Here you can set preview mode 1 4 8 9 16 window The preview channel ranges from channel 1
16. you can click ESC to exit current interface for other operation The system will not terminate backup process Note 75 When you click stop button during the burning process the stop function becomes activated immediately For example if there are ten files when you click stop system just backup five files system only save the previous 5 files in the device But you can view ten file names 4 9 PTZ Control and Color Setup Note All the operations here are based on PELCOD protocol For other protocols there might be a little difference 4 8 1 Cable Connection Please follow the procedures below to go on cable connection e Connect the dome RS485 port to DVR 485 port e Connect dome video output cable to DVR video input port e Connect power adapter to the dome 4 8 2 PTZ Setup Note The camera video should be in the current screen Before setup please check the following connections are right e PTZ and decoder connection is right Decoder address setup Is right e Decoder A B line connects with DVR A B line Boot up the DVR input user name and password In the main menu click setting and then click Pan Tilt Control button The interface is shown as in Figure 4 35 Here you can set the following items Channel select the current camera channel Protocol select corresponding PTZ protocol such as PELCOD Address default address is 1 Baud rate select corresponding baud rate Default value is 9600 Data bits select co
17. 18 Alarm signal can not been disarmed There are following possibilities e Alarm setup is not correct e Alarm output has been open manually e Input device error or connection is not correct e Some program versions may have this problem Please upgrade your system 19 Alarm function is null There are following possibilities e Alarm setup is not correct e Alarm cable connection is not correct e Alarm input signal is not correct e There are two loops connect to one alarm device 20 Remote control does not work There are following possibilities e Remote control address is not correct Distance is too far or control angle is too small e Remote control battery power is low e Remote control is damaged or DVR front panel is damaged 21 Record storage period is not enough There are following possibilities e Camera quality is too low Lens is dirty Camera is installed against the light Camera aperture setup is not correct e HDD capacity is not enough e HDD is damaged 22 Can not playback the downloaded file There are following possibilities There is no media player e No DXB8 1 or higher graphic acceleration software 171 e There is no DivX503Bundle exe control when you play the file transformed to AVI via media player e No DivX503Bundle exe or ffdshow 2004 1012 exe in Windows XP OS 23 Forget local menu operation password or network password Please contact your local service engineer or our sales person
18. 2 3 3 2U series Please refer to Figure 2 14 for connection sample 35 APTO 1 1 711 46 RS485 ss i i PTZ Control i ideo Input Alarm Input Alarm Output aena e 4 Audio Output Bidirectional Talk Input Bidirectional i P seca a Talk Output Loop Output Power Switch E gt E MS SENS Power Input 2 VGA Output HDMI Output eSATA USB Port Network Switch Online User Online User Online User Network Keyboard Online User Figure 2 14 36 2 3 4 2U series HD SDI series Please refer to the following figure for detailed information See Figure 2 15 E Bidirectional Bidirectional 7 p3 output talkinput talk output Matrix input KS232 Power input n o MA Video input a VGA output HOM output Netwprk switch n B e Online User Online User Online User Figure 2 15 2 3 4 2U series 960H series Please refer to the following figure for detailed information See Figure 2 16 37 PE 201MUA PX DE w O y Ge F w Audio Input Video Input Audio Output Alarm Input Alarm Output RS485 PTZ control Talk Input Talk Output Video Output Loop out Matrix Output Power Button Power Input HDET Network Swither Online User Online User Online User Network Keyboard Figure 2 16 2 4 Remote Control The remote control interface is shown as in Figure 2 17 Please note remote control is not our standard accessory and it is not i
19. 200 Macon 10KQ BNC 10KQ BNC 2000mv 10KO p BNC 1 ch audio output 200 1 ch audio output 200 1 ch audio output Audio 3000mv 5KQ BNC 3000mv 5KQ BNC 200 3000mv Output 5KO RCA 1 ch audio talk output 1 ch audio talk output 1 ch audio talk Bidirectional 200 3000mv 5KQ BNC 200 3000mv 5KQ BNC output 200 Audio 3000mv 5K0 RCA Hard Disk 2 built in SATA port Support 2 HDDs Hard Disk Audio PCM 28 8MByte h pak Occupation Video 56 900MByte h Manual recording motion detection recording schedule recording and alarm recording Recording Mode Priority Manual recording gt alarm recording gt motion detection recording gt schedule recording playback 1 to 120 minutes single record duration Default setup is 60 minutes Length Record and Playback Repeat When hard disk is full system can overwrite previous video file Way Various search engines such as time type and channel search Playback Various fast play slow play speeds manual frame by frame playback Mode and reverse play mode Various File Can switch to previous or next file or any file in current play list Switch Can switch to file on other channel of the same time If there is a file Ways Support file continuous play when a file is end system auto plays the next file in the current channel Multi There is 1 4 9 16 channel playback mode channel It may vary due to different series Playback Zoom Partial When in one
20. 43 Please go to Figure 4 35 use direction arrows to select camera left limit Then please go to Figure 4 43 and click left limit button Repeat the above procedures to set right limit PAN TILT ZOOM x Function Pattern 1 Preset Patrol No 0 Patrol Pattern Left Border Right Figure 4 45 4 9 8 Activate Auto Scan In Figure 4 41 click Auto Scan button the system begins auto scan Correspondingly the auto scan button becomes Stop button Click stop button to terminate scan operation 4 11 Flip In Figure 4 41 click page switch button you can see an interface is shown as below See Figure 4 46 Here you can set auxiliary function The aux value has relation ship with the Aux button of the decoder Click page switch button again system goes back to Figure 4 37 80 A PANTILT ZOOM y Direct Aux Oper Light Aux Num Oper 1 Page Switch Figure 4 46 81 5 Understanding of Menu Operations and Controls 5 1 Menu Tree This series DVR menu tree is shown as below Backup Information Setting E Search Advanced Shutdown 5 2 Main Menu HDD Info BPS Log Version Online Users General Encode Schedule RS232 Network Alarm Detect Pan Tilt Zoom Display Default HDD Management Alarm Output Abnormity Manual Record Account Auto Maintain TV Adjust Video Matrix Title Overlay Config Backup After you logged in the system main menu is shown a
21. 87 GB Record time 10 09 26 17 30 36 11 03 02 09 36 00 10 09 23 12 20 10 10 09 26 17 30 37 Figure 4 15 Playback or search in the redundant disk There are two ways for you to playback or search in the redundant disk e Set redundant disk s as read only disk or read write disk Main menu gt Advanced gt HDD management See Figure 4 15 System needs to reboot to get setup activated Now you can search or playback file in redundant disk e Dismantle the disk and play it in another PC 4 5 2 Snapshot 65 4 5 2 1 Schedule Snapshot In Encode interface click snapshot button to input snapshot mode size quality and frequency Note for 960H series 960H is added to image size In General interface please input upload interval In Schedule interface please enable snapshot function Please refer to the following figure for detailed information See Figure 4 16 GENERAL System Time 2011 04 15 11 52 38 Save Date Format YYYY MM DD Snapshot Date Separator DST Time Format 24 HOUR Language ENGLISH HDD Full Overwrite Pack Duration 60 Device No 8 Video Standard NTSC Auto Logout 10 Device ID DVR M Startup Wizard Paste Default Cancel Default Cancel ig SCHEDULE PreRecord 4 sec Redundancy Snapshot Record Type Regular MD Alaro MAD Alarm 24 00 a A 24 00 24 00 24 00 24 24 VU Default Figure 4 16 4 5 2 2 Activation Snapshot Please fo
22. Audio output Bidirectional talk input port Bidirectional talk output port Alarm input Alarm output RS485 port 15 Video VGA output HDMI port RS 232 eSATA port USB port Network port Video input straight cable to connect to the switcher or router 2 3 Connection Sample 2 3 1 1U series Please refer to Figure 2 12 for connection sample The following figure is based on the 8 channel series product 33 ail ga aa e z sa w RS485 PTZ Control mn 190 Video Input Audio Input Alarm Input Alarm Output Video Output Audio Output e Power Switch Power Input V DEO IN AUDIO IN Video Spot Output Bidirectional Talk Input HDMI Output VGA Output Network Switch Online User Online User Online User Network Keyboard Online User Figure 2 12 2 3 2 1 5U series Please refer to Figure 2 13 for connection sample 34 QE il x RS485 PTZ Control YU Video Input Alarm Output Alarm Input Ll Bidirectional Talk Output Video Output Power Switch Do A fo0000000000007 LOOP 4 1 00po00000000 AUDIO Power Input Matrix Output Loop Output Audio Input Audio Output Bidirectional Talk Input VGA Output HDMI Output eSATA USB Port Network Switch Online User Online User Online User Network Keyboard Online User Figure 2 13 Note There are slight differences for simple 1 5U connection
23. Click copy interface the interface is shown as in Figure 7 28 If you have completed the setup for channel 1 you can click 3 to copy current setup to channel 3 Or you can click 2 3 and 4 to copy current setup to channel 2 channel 3 and channel 4 All Channel Pale aj ojo ojo ejeje Figure 7 28 7 3 2 3 Schedule Here you can set different periods for various days There are max six periods in one day See Figure 7 29 Configuration ll Control Panel O O O O lt KXK K K SCHEDULE T go loon une Channel Channel 01 Prerecord 4 sec Period Info HDD INFO LOG E Regular E MD E Alarm M MDia larm 7 System Config 0 4 8 12 16 20 24 ES su S aml ALARM PAN TILTIZOOM DEFAULT BACKUP amp ADVANCED HDD MANAGEMENT ABNORMALITY Ez Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE Ga Matrix config Copy Save Refresh Figure 7 29 136 Default Current Record Snapshot Regular MD Alarm Regular MD Alarm Periodi 00 00 23 59 59 z Period2 0 00 00 23 59 59 Period3 0 00 00 23 59 59 Period 4 0 00 00 23 59 59 Period 5 0 00 00 23 59 59 Period 0 00 00 lt 23 59 59 T Al Mon Fri Cea Figure 7 30 Please refer to the following sheet for detailed information Parameter Please select a channel first Pre record Please input pre record value here System can recor
24. Compression Main Stream Video Audio Resolution Frame Rate FPS Bit Rate Type Bit Rate Kb s Reference Bit Rate Color Setting Overlay Cover 4rea lv Time Display Copy Channel 01 H264 hd Main Stream v Audio CIF v 25 v CBR l 640 bi 19271024Kbps Figure 7 26 ENCODE CHANNEL NAME CAM 1 Estra Stream Assistant v Video Audio Resolution W Video Audio QCIF v Frame Rate FPS 25 z Bit Rate Type CBR y Bit Rate Kb s 160 hs Reference Bit Rate 45 256Kbps iv Watermark E iv Channel Display Refresh Color Setting Brightness Contrast Saturation 50 0100 Figure 7 27 Please refer to the following sheet for detailed information Parameter Function Channel Here is for you to select a monitor channel Channel Name Here is to display current channel name You can modify it Main Stream It includes main stream motion stream and alarm stream You can select different encode frame rates form different recorded events System supports active control frame function ACF It allows you to record in different frame rates For example you can use high frame rate to record important events record scheduled event in lower frame rate and it allows you to set different frame rates for motion detection record and alarm record Extra Stream Select extra stream if you enabled the extension stream to monitor 134 Parameter
25. E IP Access 4 UL DL Rati 4 gt 9 License P Settings Activity AD E pS Domains Jv Write zhonghy Y Append 2 Settings Vv Delete Activity Directories Jv List 4 Create V Remove IT irectories fv Inherit a Add Delete Edit y Apply wy Restore lt lt Local Server gt gt System Administrator Down 0 000 kBps Up 0 000 kBps 3 of 32767 Sockets 0 0 Users DXfers y Figure 5 21 You can use a PC or FTP login tool to test setup is right or not For example you can login user ZHY to FTP 10 10 7 7 and then test it can modify or delete folder or not See Figure 5 22 Internet Explorer E J To log on to this FTP server type a user name and password FTP server 10 10 7 7 User name Password After you log on you can add this server to your Favorites and return to it easily C Log on anonymously Figure 5 22 System also supports upload multiple DVRs to one FTP server You can create multiple folders under this FTP In Figure 5 179 select FTP and then double click mouse You can see the following interface See Figure 5 23 o Please highlight the icon O in front of Enable to activate FTP function Here you can input FTP server address port and remote directory When remote directory is null system automatically create folders according to the IP time and channel e Username and password is the account information for you to logi
26. ES ce t J 3 0O J f AAA e LJ 0 AB cable connection A CIRL 12V NO C NC UV en Figure 3 3 You can refer to the following sheet and Figure 3 3 for alarm input and output information In the first line from ALARM 1 to ALARM 16 The alarm becomes active in low voltage the left to the right 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 In the second line The first four are four groups of normal open activation output from the left to the on off button right NO5 C5 NC5 is a group of NO NC activation output on off button NO1 C1 NO2 C2 NO3 C3 NO4 C4 NO5 C5 NC5 CTRL 12V Control power output You need to close the device power to cancel the alarm 12V It is external power input Need the peripheral equipment to provide 12V power below 1A Earth cable 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders 3 8 1 3 2U Series The 2U series product interface is shown as in Figure 3 4 123 4 5 678 9 10 1112 13 14 15 16 NO1 C1 NO2C2 NO3 C3 NO4C4 dr NO5C5NC5 SR HN b AB AB cable Figure 3 4 connection You can refer to the following sheet and 49 Figure 3 4 for alarm input and output information In the first line from ALARM
27. El deb ey Page gt G Tools Done E Internet E 100 Figure 7 66 7 8 Un install Web Control You can use web un install tool uninstall web bat to un install web control Please note before you un installation please close all web pages otherwise the un Installation might result in error 166 8 Professional Surveillance System Besides Web you can use our Professional Surveillance Software PSS to login the device For detailed information please refer to PSS user s manual 167 9 FAQ 1 DVR can not boot up properly There are following possibilities Input power is not correct Power connection is not correct Power switch button is damaged Program upgrade is wrong HDD malfunction or something wrong with HDD ribbon Seagate DB35 1 DB35 2 SV35 or Maxtor 17 g has compatibility problem Please upgrade to the latest version to solve this problem Front panel error Main board is damaged 2 DVR often automatically shuts down or stops running There are following possibilities Input voltage is not stable or it is too low HDD malfunction or something wrong wit the ribbon Button power is not enough Front video signal is not stable Working environment is too harsh too much dust Hardware malfunction 3 System can not detect hard disk There are following possibilities HDD is broken HDD ribbon is damaged HDD cable connection is loose Main board SA
28. Function Audio Video For the main stream recorded file only contains video by default You need to draw a circle here to enable audio function For extra stream you need to draw a circle to select the video first and then select the audio if necessary System supports various resolutions you can select from the dropdown list The main stream supports D1 HD1 BCIF CIF QCIF and the extra stream supports CIF QCIF Please note the option may vary Resolution due to different series Note For HD SDI series main code stream resolution types are 1080P 720P D1 HD BCIF CIF QCI Extra code stream supports resolution types as follows 1080P 720P D1 HD BCIF CIF QCI For 960H series main code stream resolution types are 960H D1 HD BCIF CIF QCIF Extra code stream supports resolution types as follows 960H D1 HD BCIF CIF QCIF Frame Rate PAL 1 25f s NTSC 1 30f s Bit Rate Type There are two options VBR and CBR Please note you can set video quality in VBR mode only Quality The value ranges from 1 to 6 The level 6 is the best video quality Bit Rate e In CBR the bit rate here is the max value In dynamic video system needs to low frame rate or video quality to guarantee the value e The value is null in VBR mode e Please refer to recommend bit rate for the detailed information ecommended Recommended bit rate value according to the resolution and frame rate you have set Here you can set video brightness contras
29. IP addresses Please note after you enabled this function only the IP listed below can access current DVR If you disable this function all IP addresses can access current DVR The system supports IPv4 and IPv6 address format 88 Please note e f you input the IPv4 address format system can change it to the IPv6 address format For example it can switch the IP 10 6 2 230 to ffff 10 6 2 230 e lf you input the IPv6 address format system needs to check its validity and optimize its format For example it can optimize IP fe80 0054 0cff fefa 1682 to fe80 54 cff fefa 1682 D IP FILTER Restricted Type Trusted Sites v IP Version IPv4 gt IP Address 1 orb mens ffff 10 6 2 230 Delete IP Delete All Default Cancel Figure 5 11 D IP FILTER Restricted Type Trusted Sites 7 IP Version IPv6 z IP Address 2001 255 258 bc52 12 2 4 7 2001 255 258 bc52 Delete IP Delete All Default Cancel Figure 5 12 5 3 5 3 NTP Setup You need to install SNTP server Such as Absolute Time Server in your PC first In Windows XP OS you can use command net start w32time to boot up NTP service NTP setup interface is shown as in Figure 5 13 e Host IP Input your PC address e Port This series DVR supports TCP transmission only Port default value is 123 e Update interval minimum value is 1 Max value is 65535 Unit minute Time zone select your corresponding time zone her
30. Note You need to have proper rights to implement the following operations Please make sure the HDD has been properly installed 4 3 1 1 Manual record menu There are two ways for you to go to manual record menu e Right click mouse or in the main menu Advanced gt Manual Record e In live viewing mode click record button in the front panel or record button in the remote control Manual record menu is shown as in Figure 4 7 4 3 1 2 Basic operation There are three statuses schedule manual stop Please highlight icon O to select corresponding channel 58 e Manual The highest priority After manual setup all selected channels will begin ordinary recording e Schedule Channel records as you have set in recording setup Main Menu gt Setting gt Schedule e Stop All channels stop recording Cancel Figure 4 7 4 3 1 3 Enable disable record Please check current channel status o means it is not in recording status e means it is in recording status You can use mouse or direction key to highlight channel number See Figure 4 8 Cancel Figure 4 8 4 3 1 4 Enable all channel recording Highlight o below All you can enable all channel recording e All channel schedule record Please highlight ALL after Schedule See Figure 4 9 When system is in schedule recording all channels will record as you have previously set Main menu gt Setting gt Schedule The corresponding indicati
31. Out Mode Schedule Manual Stop Status Figure 7 47 Save The alarm output port should not be connected to high power load directly It shall be less than 1A to avoid high current which may result in relay damage Please use the co contactor to realize the connection between the alarm output port and the load Please refer to the following sheet for detailed information Parameter Function Alarm output There are three output channels Multiple choices Please note the displayed alarm output channel amount here may vary due to the different series Activate Enable disable alarm output device After the Web activated the alarm you need to cancel the channel and then click the activation button to cancel the alarm or you need to cancel the alarm in the pop up dialogue box in local end Refresh Search alarm output status 7 3 3 3 Record Record control interface is shown as in Figure 7 48 The bit stream type includes main stream and extra stream 153 Configuration ll Control Panel RECORD Ef QUERY SYSTEM INFO RECORPO E VERSION ES HDD INFO l Ef LOG Main Stream Main Stream 44 SYSTEM CONFIG GENERAL ENCODE Made SCHEDULE Schedule Rs23z NETWORK ALARM DETECT PAMITILT IZOOM DEFAULT B4CeUP ADVANCED HOD MANAGEMENT ABNORMALITY Manual Stop AUTO PAIN TENANCE PREVIEW CONTROL ADOTIONAL FUNCTION Figure 7 48 Please refer to the following sheet for detailed information P
32. PTZ control menu in PTZ control interface In motion detection interface working with direction keys to complete setup switch channel input method 2 5 Mouse Control Left click System pops up password input dialogue box if you have not logged in mouse In real time monitor mode you can go to the main menu When you have selected one menu item left click mouse to view menu content Implement the control operation Modify checkbox or motion detection status Click combo box to pop up drop down list 40 In input box you can select input methods Left click the corresponding button on the panel you can input numeral English character small capitalized Here stands for backspace button __ stands for space button In English input mode _stands for input a backspace icon and stands for deleting the previous character In numeral input mode _ stands for clear and lt stands for deleting the previous numeral When input special sign you can click corresponding numeral in the front panel to input For example click numeral 1 you can input or you can click the numeral in the on screen keyboard directly 1 32 68 O 7 E FO Of ww Double left Implement special control operation such as double click one item in the file click mouse list to playback the video In multiple window mode double left click one channel to view in full window Double left click current video again to go back to p
33. Password Anonymous Remote Directory File Length 0 Channel Please input the Weekday i Alarm Motion General SER corresponding information oea here if you just upload the image FTP 67 Figure 4 18 4 5 4 Snapshot Disk For special series only Set one disk as snapshot Main menu gt Advanced gt HDD management and then click execute button See Figure 4 19 System needs to reboot to get current setup activated al HDD MANAGE i Alarm Set HDD Setting Alarm Release Channels Setting HDD No v Setto Read Write 7 Execute Type Read Write Status Normal Capacity 232 87 GB Record time 10 09 26 17 30 36 11 03 02 09 36 00 10 09 23 12 20 10 10 09 26 17 30 37 Figure 4 19 All scheduled snapshot files or activated snapshot files will be memorized in the snapshot disk You can search the corresponding images via Web See Figure 4 20 Select a file and then MM Search click here to view Type Parameter Operation C Record Search Begin Time 2005 9 3 13 48 25 ZEA End Time 2005 9 15 13 48 25 Download Type File v Motion z Bd Channel All Picture Open Local Record _Eatiest Hec Multiple channel Playback Bi 2 afl 4i 5I El ho File Size KB image content Select search engine here File Path You can see result here Double click file name you can view the image content
34. System can delay the record for specified time after alarm ended The latch value ranges from 10s to 300s Email If you enabled this function System can send out email to alert you when alarm occurs and ends Tour e Display the selected video in local monitor window e Tour interval and tour mode are set in DVR local menu chapter 5 3 9 Display PTZ e Here you can set PTZ movement when alarm occurs Such as go to Activation preset x when there is an alarm Capture You need to input capture channel number so that system can backup motion detection snapshot file Matrix Please note this function is valid in motion detect mode Enable Check the box here to enable video matrix function Right now system supports one channel tour function System takes first come and first serve principle to deal with the activated tour System will process the new tour when a new alarm occurs after previous alarm ended Otherwise it restores the previous output status before the alarm activation Copy It is a shortcut menu button You can copy current channel setup to one or more all channels Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Refresh Click this button to get device latest configuration information 7 3 2 8 PTZ PTZ interface is shown as in Figure 7 44 Please note before operation please make sure you have set soeed dome address And D
35. accessories recommended by manufacturer Before installation please open the package and check all the components are included Contact your local retailer ASAP if something is broken in your package 7 Lithium battery Improper battery use may result in fire explosion or personal injury When replace the battery please make sure you are using the same model 1X 1 FEATURES AND SPECIFICATIONS 1 1 Overview This series product is an excellent digital monitor product designed for security field It adopts embedded Linux OS to maintain reliable operation Popular H 264 compression algorithm and G 711 audio compression technology realize high quality low bit stream Unique frame by frame play function is suitable for detail analysis lt has various functions such as record playback monitor at the same time and can guarantee audio video synchronization This series product has advanced technology and strong network data transmission function This series device adopts embedded design to achieve high security and reliability lt can work in the local end and at the same time when connecting it to the professional surveillance software PSS it can connect to security network to realize strong network and remote monitor function This series product can be widely used in various areas such as banking telecommunication electric power interrogation transportation intelligent resident zone factory warehouse resources and water cons
36. and Connections Note All the installation and operations here should conform to your local electric safety rules 3 1 Check Unpacked DVR When you receive the DVR from the forwarding agent please check whether there is any visible damage The protective materials used for the package of the DVR can protect most accidental clashes during transportation Then you can open the box to check the accessories Please check the items in accordance with the list on the warranty card Remote control is optional Finally you can remove the protective film of the DVR Note Remote control is not a standard accessory and it is not included in the accessory bag 3 2 About Front Panel and Real Panel The model label in the front panel is very important please check according to your purchase order The label in the rear panel is very important too Usually we need you to represent the serial number when we provide the service after sales 3 3 HDD Installation You can refer to the Appendix for recommended HDD brand Please follow the instructions below to install hard disk 3 3 1 1U series This series DVR has two SATA HDDs Please use HDD of 7200rpm or higher a lt A a A z 4 1 Loosen the screws of the 2 Fix four screws in the HDD 3 Place the HDD in accordance with upper cover and side panel Turn just three rounds the four holes in the bottom 4 Turn the device upside down 5 Fix the HDD firmly 6 Connect the HDD cabl
37. check the corresponding item here See Figure 7 46 151 Configuration Control Panel HDD MANAGEMENT Ef Query System Info HDD MANAGEMENT VERSION z HDD HDD INFO 2 A LOG Local 01 Format 7 System Config id C Read Write GENERAL ENCODE C Read Only SCHEDULE R5232 NETWORK ALARM DETECT PAN TILT ZOOM rc DEFAULT BACKUP ADVANCED E HDD MANAGEMENT ABNORMITY Alarm I O Config Record ACCOUNT 3 SNAPSHOT AUTO MAINTENANCE ADDTIONAL FUNCTION DNS C Recover Figure 7 46 Please refer to the following sheet for detailed information Parameter Function Format Clear data in the disk Read write Set current disk as read write Read only Set current disk as read Redundant Set current disk as redundant disk Recover Recover dada after error occurs Use as Set current disk as snapshot disk snapshot Please note system needs to reboot to activate current setup 7 3 3 2 Alarm I O Here you can search alarm output status See Figure 7 47 152 Configuration Control Panel Bf Query System Info B VERSION E HDD INFO B LOG 4 System Config GENERAL 3 ENCODE SCHEDULE a R5232 NETWORK Ea ALARM 3 DETECT Ez PAN TILT ZOOM Ea DEFAULT BACKUP ADVANCED a ABNORMALITY SE Ez Record Ea ACCOUNT La SNAPSHOT La MATRIX SPOT Important Ea HDD MANAGEMENT AUTO MAINTENANCE ADDTIONAL FUNCTION Alarm 1 0 Contig Alarm
38. contrast saturation and gain setup for each channel Configuration Audio 4 ch 200 2000mv 8 ch 200 2000mv 16 ch 200 10KQ BNC 10KQ BNC 2000mv 10KQ BNC 1 ch audio output 200 3000mv 5KQ BNC Audio Output Monitor Support monitor tour functions such as alarm motion detection and Touring schedule auto control PAL 625TVL 50f s NTSC 525TVL 60f s Real time monitor 960H 960 x576 960x480 Playback channel 1 16 960 x576 960x480 Resolution 176x144 176x120 Support dual streams Extra stream resolution CIF 352X 288 352x240 QCIF 176x144 176x120 Image Quality 6 level image quality Adjustable Privacy mask Support one privacy mask of user defined size in full screen Support max 4 zones Image ne Channel information time information and privacy mask zone Bidirectional 1 ch audio talk input 200 3000mv 10KQ BNC Audio 1 ch audio talk output 200 3000mv 5K 2 BNC 8 built in SATA port Support 8 HDDs Hard Disk Audio PCM 28 8MByte h Manual recording motion detection recording schedule recording and Recording alarm recording Mode Priority Manual recording gt alarm recording gt motion detection recording gt schedule recording playback 1 to 120 minutes single record duration Default setup is 60 minutes Length Playback Repeat Way When hard disk is full system can overwrite previous video file Record Search Various search engines such as time type and channel Playback Various fast play slow play speeds
39. donation and etc Activate current control modify setup and then move up and down Up 1 A Increase decrease numeral Down 4 Assistant function such as PTZ menu In text mode input number 1 4 English character G H Shift current activated control Left 2 Right 3 When playback click these buttons to control playback bar In text mode input number 2 English character A B C 3 English character D E F Confirm current operation Enter ENTER Go to default button Go to menu Manually stop start recording working with direction keys Record or numeral keys to select the recording channel Slow play 8 CS Multiple slow play speeds or normal playback In text mode input number 8 English character T U V est F One window monitor mode click this button to display assistant function PTZ control and image color 23 Go to previous menu or cancel current operation When playback click it to restore real time monitor mode D ESC REC n Backspace function in numeral control or text control press it for 1 5seconds to delete the previous character before the cursor In motion detection setup working with Fn and direction keys to realize setup In text mode click it to switch between numeral English character small capitalized and etc Fast play 7 Realize other special functions other Realize other special functions functions Various fast speeds and normal playback In text mode input number 7
40. for help We can guide you to solve this problem 172 Appendix A HDD Capacity Calculation Calculate total capacity needed by each DVR according to video recording video recording type and video file storage time Step 1 According to Formula 1 to calculate storage capacity q that is the capacity of each channel needed for each hour unit Mbyte q d 8 x 3600 1024 1 In the formula d means the bit rate unit Kbit s Step 2 After video time requirement is confirmed according to Formula 2 to calculate the storage capacity m which is storage of each channel needed unit Mbyte m q x h x D 2 l In the formula h means the recording time for each day hour D means number of days for which the video shall be kept Step 3 According to Formula 3 to calculate total capacity accumulation q that is needed for all channels in the DVR during scheduled video recording dr 2M 3 i In the formula c means total number of channels in one DVR Step 4 According to Formula 4 to calculate total capacity accumulation q that is needed for all channels in DVR during alarm video recording including motion detection dr Dm xa 4 i In the formula a means alarm occurrence rate 173 Appendix B Compatible Backup Device List Compatible USB drive list NOTE Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below If you use the USB drive please confir
41. for you to select local play file See _ Figure 7 10 125 Open Look in 2 Desktop e a ex EX 6 My Documents Qe Norton Antivirus E nioc 0 My Computer ES ThinkVantage Technologies Secu O Network Places ai wireless Manager B access IBM 2008_04_08 AE AOL Double Click to Start B EarthLink Internet 30 Days Free E CCF09042008_00000 Se mM EA Files of type Record files y Cancel Figure 7 10 7 2 2 PTZ Before PTZ operation please make sure you have properly set PTZ protocol Please refer to chapter 7 3 2 Setting gt Pan Tilt Zoom Click PTZ button the interface is shown as in Figure 7 11 3D Intelligent Positioning speedil 81 5 F Zoom Focus Iris r Mo 1 127 1 Preset Auto Tour You can click this icon to Auto Pan Auto Scan display or hide the PTZ Pattern AUX Open control platform ALA Close PTZ Set S Figure 7 11 7 2 2 1 Direction key and 3D positioning key In Figure 7 10 there are eight direction keys In the middle of the eight direction keys there is a 3D intelligent positioning key 126 Click 3D intelligent positioning key system goes back to the single screen mode Drag the mouse in the screen to adjust section size lt can realize PTZ automatically 7 2 2 2 Speed System supports eight level speed You can select from the dropdown list Speed 2 is faster than speed 1 7 2 2 3 Zoom Focus Iris Here is a sheet for you ref
42. information Please make sure current device can upload the alarm Alarm System alarms when video loss occurs Type Motion detection System alarms when motion detection alarm occurs Disk full System alarms when disk is full System alarms when disk error occurs Camera System alarms when camera is viciously masking masking Encode alarm System alarms when peripheral device alarms External alarm Alarm input device sends out alarm Operation Listen alarm System notifies web when alarm occurs you select from the above event type and then web can notify user Video When alarm occurs system auto enables video monitor This function only applies to video detection alarm motion detection video loss and camera masking Automatically pops up alarm dialogue box Sound pop up System sends out alarm sound when alarm occurs You can specify as you wish Here you can specify alarm sound file 7 6 About Click about button you can view current web client information See Figure 7 65 165 Webrec Control Version 2 1 7 15 NETSOR Version 3 3 4 1 PLAYS Ok Version 3 26 0 114 Copyright C 2008 Figure 7 65 7 7 Log out Click log out button system goes back to log in interface See Figure 7 66 You need to input user name and password to login again gt WEBservice Windows Internet Explorer EE http 10 10 3 16 elo lio 1228 Px Hry y 7 A w e Gwesservice A
43. is not compatible with Windows VISTA control ActiveX control has been disabled No dx8 1 or higher Please upgrade display card driver Network connection error Network setup error Password or user name is invalid Client end is not compatible with DVR program 14 There is only mosaic no video when preview or playback video file remotely There are following possibilities Network fluency is not good Client end resources are limit There is multiple cast group setup in DVR This mode can result in mosaic Usually we do not recommend this mode There is privacy mask or channel protection setup Current user has no right to monitor DVR local video output quality is not good 15 Network connection is not stable There are following possibilities Network is not stable IP address conflict MAC address conflict PC or DVR network card is not good 16 Burn error USB back error There are following possibilities Burner and DVR are in the same data cable 170 System uses too much CPU resources Please stop record first and then begin backup Data amount exceeds backup device capacity lt may result in burner error Backup device is not compatible Backup device is damaged 17 Keyboard can not control DVR There are following possibilities e DVR serial port setup is not correct e Address is not correct When there are several switchers power supply is not enough Transmission distance is too far
44. light change the system can alert you to guarantee video continuity Camera masking interface is shown as in Figure 4 27 Tips You can enable preset tour pattern activation operation when video loss occurs Please refer to chapter 4 5 2 motion detection for detailed information Note In Detect interface copy paste function is only valid for the same type which means you can not copy a channel setup in video loss mode to camera masking mode Camera Maski Channe Set Message Ml Alarm upload Ml Send Email hannel ij Select Default Figure 4 27 4 7 Alarm Setup and Alarm Activation Before operation please make sure you have properly connected alarm devices such as buzzer 4 7 1 Go to alarm setup interface In the main menu from Setting to Alarm you can see alarm setup interface See Figure 4 28 4 7 2 Alarm setup Alarm interface is shown as below See Figure 4 28 e Alarm in Here is for you to select channel number e Event type There are two types One is local input and the other is network input e Type normal open or normal close e PTZ activation Here you can set PTZ movement when alarm occurs Such as go to preset tour pattern when there is an alarm Click select button you can see an interface is shown as in Figure 4 29 e Period Click set button you can see an interface is shown as in Figure 4 30 Here you can set for business day and non business day In Figure 4 30 click set button y
45. o ATA 176 HATOTUUICE SATA 177 APPENDIX C Compatible CD DVD Device List NOTE Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below And you can use the USB cable with the model recommended to set USB burner Manufacturer Model PomType Tye Sony Sony er Sony BenQ 178 Appendix D Compatible Displayer List Please refer to the following sheet for the compatible device brand Brand Moda Dimension Unit inch Q7T3 LXB L17C Samsung LCD 2243EW 179 Appendix E Compatible Switcher List Please refer to the following sheet form compatible switcher list Brand Mod Network Working Mode DES 1016D 10 100M self adaptive DES 1008D 10 100M self adaptive There are five network modes 1 AUTO RG 519265 2 HALF 10M 3 FULL 10M 4 HALF 100M 5 FULL 100M H3C S1024 10 100M self adaptive TP LINK TL SF1016 10 100M self adaptive TP LINK TL SF1008 10 100M self adaptive 180 Appendix F Compatible Wireless Mouse List Please refer to the following sheet for compatible SD card brand Band IMA 3500 Logitech M215 Shuangfeiyan Tianyao G7 630 181 Appendix G Earthing 1 What is the surge Surge is a short current or voltage change during a very short time In the circuit it lasts for microsecond In a 220V circuit the 5KV or 10KV voltage change during a very short time about microseconds can be called a surge The surge comes from two way
46. please save the system setup otherwise you may lose the data completely 4 2 Live Viewing After you logged in the system is in live viewing mode You can see system date time and channel name If you want to change system date and time you can refer to general settings Main Menu gt Setting gt General If you want to modify the channel name please refer to the display settings Main Menu gt Setting gt Display DI MEA mem 2 E monon a Preview Control The preview control function has the following features e Support preview playback lt gt Inthe preview desktop system can playback max previous 5 minute record of current channel lt gt Support drag and play function You can use your mouse to select any playback start time within the previous 5 minutes lt gt Support playback pause and exit function lt gt Right now system does not support slow playback and backward playback function e Support digital zoom function e Support real time backup function You can follow the contents listed below for the operation instruction Preview control interface Move you mouse to the centre of the video of current channel 1 4 3 4 area you can see system pops up the preview control interface See Figure 4 6 Left click the icon you can see a hook icon Now you have enabled the preview zoom function You can drag the mouse to zoom in the image Figure 4 6 57 You can refer to the following sheet for detailed i
47. setup You can select corresponding items Backup Export current configuration to local PC or import configuration from current PC Please refer to Figure 7 45 Please note system can not restore some information such as network IP address 150 ll Control Panel DEFAULT BACKUP 2 Query System Info Please select setting entries that you want to default Ef VERSION qe ee Mess Default 44 System Contig GENERAL mw GENERAL w ENCODE ENCODE SCHEDULE m SCHEDULE AS232 R5232 NETWORK ALARM W DETECT w PAN TILT ZOOM DETECT PAN TILT ZOOM 5 DEFAULT BACKUP ADVANCED HDD MANAGEMENT ABNORMITY Alarm IO Config Record Default Path C Documents and Settings 10887 Desktop ACCOUNT Export Config Import Config SHAaPSHOT AUTO MAINTENANCE ADDTIONAL FUNCTION DNS w NETWORK Ww ALARM Ww DISPLAY mw CHANNEL NAME Config Backup Figure 7 45 Please refer to the following sheet for detailed information Select All Restore factory default setup Export Export system configuration to local PC Configuration Import Import configuration from PC to the system Configuration 7 3 3 Advanced 7 3 3 1 HDD Management HDD management includes net storage management and local storage management Please note if you want to use local storage function your storage device need to support current function Please select the storage device first and then you can see the items on your right become valid You can
48. supports two types CBR and VBR In VBR mode you can set video quality Quality There are six levels ranging from 1 to 6 The sixth level has the highest image quality Video audio You can enable or disable the video audio Overlay Click overlay button you can see an interface is shown in Figure 5 7 Cover area Privacy mask Here is for you to set privacy mask section You can drag you mouse to set proper section size In one channel video system max supports 4 zones in one channel Preview monitor privacy mask has two types Preview and Monitor Preview means the privacy mask zone can not be viewed by user when system is in preview status Monitor means the privacy mask zone can not be view by the user when system is in monitor status Time display You can select system displays time or not when you playback Please click set button and then drag the title to the corresponding position in the screen Channel display You can select system displays channel number or not when you playback Please click set button and then drag the title to the corresponding position in the screen Please highlight icon O to select the corresponding function 85 a ENCODE Channel 1 Type Regular Compression H 264 Extra Stream1 y Resolution CIF QCIF gt Frame Rate FPS 25 25 Bit Rate Type CBR CBR Bit Rate Kb S 640 y 160 y Reference Bit Rate 160 896Kb S 40 224Kb S Audio Video a OVERLAY SNAPSHOT Default Pre Step Next Step Cancel
49. to channel 16 See Figure 7 53 157 Configuration ll Control Panel MPT Tz gt wIl z PREVIEW CONTROL Bf QUERY SYSTEM INFO BP VERSION my HDD INFO Preview Mode spit el Ef LOG SYSTEM CONFIG y ADVANCED Ea HDD MANAGEMENT Preview Channel 01 y La ABNORMALITY Ea ALARM I O CONFIG Da RECORD Ea ACCOUNT Ca SNAPSHOT AUTO MAINTENANCE A J ADDTIONAL FUNCTION Figure 7 53 7 3 4 Additional Function 7 3 4 1 Preferred DNS Here you can set server or local operator DNS address See Figure 7 54 Configuration ll Control Panel BF Query System Info B VERSION B HDD INFO Ef LOG 41 System Config GENERAL ENCODE Preferred DNS 3 SCHEDULE R5232 Ea NETWORK Alternate DNS ALARM Da DETECT PAN TILT ZOOM DEFAULT BACKUP y ADVANCED Ea HDD MANAGEMENT ABNORMALITY Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE MATRIX CONFIG MATRIX SPOT ADDTIONAL FUNCTION CARD OVERLAY Auto Register al Preferred DNS Refresh Figure 7 54 7 3 4 2 Card Overlay Tit is the same with the card overlay function chapter 5 5 9 It is mainly for financial areas to Sniffer information parse and character overlay The ATM POS interface is shown as in Figure 7 595 158 Source IP refers to host IP address that sends out information usually it is the device host connected to the DVR Destination IP refers to other systems that receive information There are total four groups IP The record channel applie
50. to exit the region setup interface system will not save your zone setup Sensitivity System supports 6 levels The sixth level has the highest sensitivity Show message System can pop up a message to alarm you in the local host screen if you enabled this function Alarm upload System can upload the alarm signal to the network including alarm centre if you enabled current function Send email System can send out email to alert you when alarm occurs PTZ activation Here you can set PTZ movement when alarm occurs Such as go to preset tour amp pattern when there is an alarm Click select button you can see an interface is shown as in Figure 4 23 Period Click set button you can see an interface is shown as in Figure 4 24 Here you can set for business day and non business day In Figure 4 24 click set button you can see an interface is shown as in Figure 4 25 Here you can set your own setup for business day and non business day Anti dither Here you can set anti dither time Alarm output when alarm occurred system enables peripheral alarm devices Tour Here you can enable tour function when alarm occurs System one window tour Please go to chapter 5 3 9 Display for tour interval setup Snapshot You can enable this function to snapshoot image when alarm occurs Please highlight icon m to select the corresponding function After all the setups please click save button system goes back to the previous menu Note 6
51. window full screen playback mode you can select any zone Enlargemen to activate partial enlargement function t Backup HDD backup function Backup Support peripheral USB backup device Flash disk portable disk and etc Merete Support peripheral USB burner Support network download and backup View monitor channel remotely DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance View alarm information such as external alarm motion detection and video loss via client Support network PTZ lens control File download backup and playback Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Motion Detection Various sensitivity levels Detection and Alarm can activate record or external alarm or screen message prompt Alarm Video Loss Alarm can activate external alarm or screen message prompt External Support record activation function or activate external alarm or screen Alarm message in specified period Network Function Network control Manual Enable or disable alarm input channel Control 4 ch alarm input You 8 ch alarm input You 16 ch alarm input can set normal open or can set normal open or You can set normal close type to normal
52. 06006060666060606060060 0606006066060 A 0000000000000 0000050000000000000000000000000000000005000000 ta pa O 000000000 OOOO O a p0000000000000500090000000000000000000000000000500000000000000 a GEC EASTER RESO ERARC MERE RRR ERE ERH REHAB e eee eaeneeae Figure 2 2 Please refer to the following sheet for front panel button information i Power button press this button for three seconds to boot up Power button O or shut down DVR USB port To connect USB storage device USB mouse Activate current control modify setup and then move up and down Up Increase decrease numeral pow Assistant function such as PTZ menu Input number 1 4 Left Shift current activated control and then move left and right e Right When playback click these buttons to control playback bar Input number 2 3 Confirm current operation Enter ENTER Go to default button Go to menu In normal playback or pause mode click this button to reverse Playback Input number 5 In normal playback click this button to pause playback In pause mode click this button to resume playback Input number 6 Multiple slow play speeds or normal playback Input number 8 Various fast soeeds and normal playback mast play oa Input number 7 j lt Reverse Pau Play Pause Slow play Play previous In playback mode playback the previous video Input number 9 In playback mode playback the next video Play Next Inp
53. 1 0Vp p 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output Video monitor Video 1 ch VGA output Output 1 ch HDMI output 1 ch matrix output Support TV VGA HDMI video output at the same time Video PAL 625 line 50f s NTSC 525 line 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s per channel Record Speed Partition Touring schedule auto control PAL NTSC Real time monitor D1 704x576 704x480 Resolution PAL NTSC Playback 1 16 ch D1 704x576 704x480 HD1 704x288 704x240 BCIF 352x576 352x480 CIF 352x288 392x240 QCIF 176x144 176x120 Support dual streams extra stream resolution CIF 352x288 352x240 QCIF 176x144 176x120 6 level image quality Adjustable Quality Support one privacy mask of user defined size in full screen mask Support max 4 zones Im ae ue Channel information time information and privacy mask zone Information Adjust TV output zone suitable to anamorphic video Channel Cover secret channel with black screen though system is encoding Lock normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection status are shown on the bottom left of display screen Color Hue brightness contrast saturation and gain setup for each channel Configuratio n Audio 4 ch 200 2000mv 8 ch 200 2000mv 4 ch
54. 1 to ALARM 16 The alarm becomes active in low voltage the left to the right 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 In the first line after The first four are four groups of normal open activation output the number 1 16 on off button from the left to the NO5 C5 NC5 is a group of NO NC activation output on off button right NO1 C1 NO2 C2 NO3 C3 NO4 C4 NO5 C5 NC5 the alarm 12V It is external power input Need the peripheral equipment to provide 12V power below 1A Earth cable 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders 2U Series HD SDI series gt F OK y LL TTT 1 2 3 L I fie wiev i L 4 T T R R A 86 7 11 17 TT Ll efell Fbi Je In the first line from ALARM 1 to ALARM 4 The alarm becomes active in low voltage the left to the right 1 gt 2 r 4 In the first line after The first four are four groups of normal open activation output the number 1 4 on off button from the left to the NO5 C5 NC5 is a group of NO NC activation output on off button right NO1 C1 NO2 C2 NO3 C3 NO4 C4 NO5 C5 NC5 Earth cable T T R R RS485 port 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders 2U Series
55. 2 2 color chapter 7 2 3 button and you can also select picture path and record path e Section 4 real time monitor window Please note current preview window is circled by a green rectangle zone e Section 5 Here you can view window switch button You can also select video priority between fluency or real time lt gt System monitor window switch supports full screen 1 window 4 window 6 window 8 window 9 window 13 window 16 window 20 window 25 window 36 window See Figure 7 4 Bo 2 0 80 86 6 BA E E 5 ss Figure 7 4 lt gt Preview window switch System support 1 4 8 9 16 window real time preview Please you need to have the proper rights to implement preview operation You can not preview if you have no right to preview the either channel See Figure 7 5 Please note this series device does not support this function Qs FH GH GE Ed Figure 7 5 gt Section 4 Zoom Figure 7 6 123 7 2 1 Real time Monitor In section 2 left click the channel name you want to view you can see the corresponding video in current window On the top left corner you can view device IP channel number network monitor bit stream 3 78 4 499Kbps Figure 7 7 On the top right corer there are six unction buttons See Figure 7 8 ie o 12 34 5 6 Figure 7 8 eo 1 Digital zoom Click this button and then left drag the mouse in the zone to zoom in right click mouse system restores original s
56. 2 gt SEARCH 2011 04 14 13 27 24 User logged out lt admin gt lt Video Loss lt Video Loss lt Video Loss lt Video Loss lt Video Loss lt Video Loss User logged in lt 888888 gt lt Video Loss 4 gt lt Video Loss 3 gt User logged out lt admin gt User logged out lt admin gt lt Video Loss 3 gt CaarnbCr etH9N11 04 14 16 99 9441 Backup Clear e Figure 7 21 Click backup button the interface is shown as in Figure 7 22 Save jn Ej Desktop e My Computer my Documents dry Network Places File name 2009 07 10 11_ 24 32 41 Save Save as type Log File log Cancel Figure 7 22 Please refer to the following sheet for log parameter information Parameter Function Log types include system operation configuration operation data management alarm event record operation user management log clear and file operation You can select log type from the drop down list and then click search button to view the list Start time Please input start time here Please input the end time here Clear You can click this button to delete all displayed log files Please note system does not support clear by type 131 Parameter Function More Select one item and click this button you can view the detailed log details information You can click this button to backup log files to current PC 7 3 2 System Configuration Please click save button to
57. 3 to avoid conflict For the TCP and UDP please make sure the internal port and external port are the same to guarantee the proper data transmission UPNP Status unknow RouterLANIP O 0 WAN IP 0 0 _ 3 Service Name 1 MI HITP 207 Cr 3 Ivy UDP Default Add to the List UPNP Protocol Delete Int Port 80 31771 37778 Cancel Figure 5 17 PORT INFO Service Name O Protocol Int Port Ext Port 9 3 0 8 Email ice 37777 31171 Cancel Figure 5 18 The email interface is shown as below See Figure 5 19 e SMTP server Please input your email SMTP server IP here Port Please input corresponding port value here User name Please input the user name to login the sender email box Password Please input the corresponding password here Sender Please input sender email box here 93 e Title Please input email subject here System support English character and Arabic number Max 32 digit Receiver Please input receiver email address here System max supports 3 email boxes SSL enable System supports SSL encryption box Interval The send interval ranges from 0 to 3600 seconds 0 means there is no interval Health email enable Please check the box here to enable this function This function allows the system to send out the test email to check the connection is OK or not Interval Please check the above box to enable this function and then set the corresponding interval System c
58. 80P 1920 1080 Recording playback channel1 4 1080P 1920 1080 720P 1280 720 Resolution D1 704x576 704x480 CIF 352x288 352x240 PAL NTSC QCIF 176x144 176x120 Dual stream supported Extra stream resolution1080P 1920 1080 720P 1280 720 D1 704x576 704x480 CIF 352x288 352x240 QCIF 176x144 176x120 6 level image quality Adjustable Quality 16 Hard disk Record and playback Backup function Privacy Support one privacy mask of user defined size in full screen mask Support max 4 zones Im saat aCe Channel information time information and privacy mask zone Information TV Adjust Adjust TV output zone suitable to anamorphic video Channel Cover secret channel with black screen though system is encoding Lock normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection status are shown on the bottom left of display screen Color Hue brightness contrast saturation and gain setup for each channel Configuratio n Audio Input 4 ch 200 2000mv 10KQ BNC Audio 1 ch audio output 200 3000mv 5KO BNC Output Bidirectional 1 ch audio talk output 200 3000mv 5K 2 BNC Audio Hard Disk 8 built in SATA port Support 8 HDDs Occupation Video 56 3600MByte h Manual recording motion detection recording schedule recording and Recording alarm rec
59. 9 In motion detection mode you can not use copy paste to set channel setup since the video in each channel may not be the same In Figure 4 22 you can left click mouse and then drag it to set a region for motion detection Click Fn to switch between arm withdraw motion detection After setting click enter button to exit DETECT Motion Detect Select Set EN MW Alarm upivcad Select Paste Default Cancel Figure 4 21 Figure 4 22 P Paman XA CAM 1 CAM 2 CAM 3 CAM 4 CAM 5 CAM 6 CAM 7 CAM 8 CAM 9 CAM 10 CAM 11 CAM 12 CAM 13 CAM 14 CAM 15 CAM 16 Sj Oo Oo 9 19 19 9 Cancel Figure 4 23 70 Work Day x 00 00 24 00 00 00 24 00 00 00 24 00 Default Cancel Figure 4 25 4 5 3 Video Loss In Figure 4 21 select video loss from the type list You can see the interface is shown as in Figure 4 26 This function allows you to be informed when video loss phenomenon occurred You can enable alarm output channel and then enable show message function Tips You can enable preset activation operation when video loss occurs Please refer to chapter 4 5 2 motion detection for detailed information Video Loss m Set Eg ssage MY Alarm upload Select El ll NE BR BPT Buz y e Paste Default Cancel Figure 4 26 4 5 4 Camera Masking 71 When someone viciously masks the lens or the output video is in one color due to the environments
60. 960H series 50 3 P e TTI TTT TTS STITT TT TTT iste ET 12 34 L 5678 9 10 11 12 4 13 14 15 16 NOT CI NO2 C2 NO3 C3 NO4 C4 NOS CS NCS T Fa T T R R AB f In the first line from ALARM 1 to ALARM 16 The alarm becomes active in low voltage the left to the right 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 In the first line after The first four are four groups of normal open activation output the number 1 4 on off button from the left to the NO5 C5 NC5 is a group of NO NC activation output on off button right NO1 C1 NO2 C2 NO3 C3 NO4 C4 NO5 C5 NC5 the alarm It is external power input Need the peripheral equipment to provide 12V power below 1A Earth cable T T R R RS485 port 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders 8 2 Alarm Input Port lease refer to the following sheet for more information Normal open or Normal close type Please parallel connect COM end and GND end of the alarm detector Provide external power to the alarm detector Please parallel connect the Ground of the DVR and the ground of the alarm detector Please connect the NC port of the alarm sensor to the DVR alarm input ALARM Use the same ground with that of DVR if you use external power to the alarm device Alarm input public end should jump out
61. ACCOUNT SNAPSHOT AUTO MAINTENANCE ADDTIONAL FUNCTION Save Refresh Figure 7 36 You can refer to the following sheet for time zone information City Region Name Middle Atlantic Time GMT 2 Alarm Centre Alarm centre interface is shown as below See Figure 7 37 This interface is for you to develop The alarm signal can be uploaded to the alarm centre when there is local alarm Please set the corresponding parameters such as server IP port and etc The system can send out the data as the protocol defined to the client end 143 Configuration Control Panel _E ALARM CENTER Bf Query System Info teats Bf VERSION Ef LOG R F System Config Port 0 0765535 GENERAL ENCODE Everyday vl SCHEDULE R5232 NETWORK EMAIL La DONS NAS NTP E ALARM CENTER ALARM DETECT La PAN TILT ZOOM DEFAULT BACKUP amp ADVANCED HDD MANAGEMENT ABNORMITY Alarm I O Config Record ACCOUNT SNAPSHOT La AUTO MAINTENANCE ADDTIONAL FUNCTION Save Refresh Figure 7 37 Advanced The advanced interface is shown as in Figure 7 38 e Multiple cast Please refer to chapter 5 3 5 3 for detailed multiple cast setup information e PPPoE Please input the PPPoE user name and password you get from the IPS internet service provider and enable PPPoE function Please save current setup and then reboot the device to get the setup activated Device connects to the internet via PPPoE after reboot You can get the IP a
62. ANITILT ZOOM gt lt Function Preset 1 Preset Patrol No i0 Patrol R Pattern Set Border Del Preset Figure 6 7 6 2 2 Activate Preset In _ Figure 6 6 please input preset number in the No blank and click preset button 6 2 3 Patrol Setup In Figure 6 5 click patrol button The interface is shown as in Figure 6 8 Input preset number and then add this preset to one patrol PAN TILT ZOOM __ Function Preset 1 Preset Patrol No Patrol Pattern Add Preset Border Del Preset Figure 6 8 6 2 4 Activate Patrol In _ Figure 6 6 input patrol number in the No blank and click patrol button 6 2 5 Pattern Setup In _ Figure 6 5 click pattern button and then click begin button The interface shows like Figure 6 9 118 Please go to Figure 6 2 to modify zoom focus and iris Go back to _ Figure 6 9 and click end button You can memorize all these setups as pattern 1 PY PAN TILT ZOOM Function Pattern 1 Preset Patrol No 10 Patrol Pattern Begin Border End Figure 6 9 6 2 6 Activate Pattern Function In Figure 6 6 input mode value in the No blank and click pattern button 6 2 7 Border Setup In Figure 6 5 click border button The interface is shown as in Figure 6 10 Please go to Figure 6 2 use direction arrows to select camera left limit and then please go to Figure 6 10 and click left limit button Repeat the above procedures to set right limit WD PAN TILTIZOOM X
63. Alarm i X Select hai A gt iB w Vid Default Cancel Figure 4 28 PTZ Activation None None None None None None None oe 19 9 9 O e 19 19 19 19 19 oe o None OK Figure 4 29 73 NS Work Day gt 00 00 24 00 00 00 24 00 00 00 24 00 Cancel Cancel Figure 4 31 4 8 Backup DVR support USB device backup and network download Here we introduce USB backup You can refer to Chapter 7 Web Client Operation for network download backup operation 4 7 1 Detect Device Click backup button you can see an interface is shown as in Figure 4 32 Here is for you to view devices information You can view backup device name and its total space and free space The device includes USB burner flash disk SD card and portable HDD T BACKUP Type ace Total Space Device Status v sdb1 USB DISK 3 71 GB 3 71 GB 14 Page Up Page Down Fn Select Cancel backup device or file Detect Backup Erase Stop Figure 4 32 4 8 1 Backup Select backup device and then set channel file start time and end time 74 Click add button system begins search All matched files are listed below System automatically calculates the capacity needed and remained See Figure 4 33 system only backup files with a Y before channel name You can use Fn or cancel button to delete y after file serial number Click backup button you can backup selected files There is a p
64. Auto Register 159 Please refer to the following sheet for detailed information Parameter Function Enable Enable auto register function No Device management server number IP Device management server IP address Port Server port number Device ID Device ID in the device management server 7 3 4 4 3G The 3G setup interface is shown as in Figure 7 57 Co nfiguration Control Panel BF QUERY SYSTEM INFO Wireless Type Edf VERSION APN Ef HDD INFO Ef LOG Dial up Serial 7 SYSTEM CONFIG By ADVANCED ADDTIONAL FUNCTION Username La CARD OVERLAY AUTO REGISTER Password lt lt 3G CONFIG Alive Period MOBILE CONFIG Da WIFI CONFIG Authentication Mode Wireless Setting SIM UIM Status PPP Dial Status IP Address Subnet Mask Gateway Wireless Signal Sais Inexistence Refresh Figure 7 57 3G Setup 7 3 4 5 Mobile Config The mobile setup interface is shown as in Figure 7 58 160 Configuration Control Panel Message Sent SMS Activate Phone Activate E EJ QUERY SYSTEM INFO EJ VERSION Ef HDD INFO Receiver Sender Caller Ef LOG PE SYSTEM CONFIG Au _Detete __ Add _ Delete Add Delete y ADVANCED Receiver SMS Activate ADDTIONAL FUNCTION CARD OVERLAY AUTO REGISTER 3G CONFIG Phone Activate Message SMS v Title DVR Message Save Received Messages Save Sent Messages Refresh Save Dialed Phone
65. C 12V DC 12V output port output port output port output port output port Alarm Relay 30V DC 2A 125VAC 1A activation alarm USB Interface 3 USB 2 0 ports Interface RJ45 10M 100M 1000M self adaptable Ethernet port connection 4 ch alarm 8 ch alarm 16 ch alarm 16 ch alarm 16 ch alarm input You input You input You input You input You can set can set can set can set can set normal normal normal normal normal Alarm Input open or open or open or open or open or normal normal normal normal normal close type close type close type close type close type to select the to select the to select the to select the to select the alarm alarm alarm alarm alarm type type type type type PTZ control port Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network System Hard Disk Display HDD current status Statistics upport various search engines such as time and type ver ersion amount system version and release date On line user Multi lever user management various management modes Integrated management for local user serial port user and network User Management User Management user Configurable user power No limit to the user or group amount Password Administrator can modify other user s password Five times login failure in thirty minutes may result in account lock Upgrade Web browser client end and update tool Password l
66. Double click shutdown button system pops up a dialogue box for you to select See Figure 5 60 e Logout menu user log out menu You need to input password when you login the next time o Restart application reboot DVR e Shutdown system shuts down and turns off power eo Restart system system begins rebooting e Switch user you can use another account to log in Restart application Shutdown Restart system Switch user Figure 5 60 115 6 About Auxiliary Menu 6 1 Goto Pan Tilt Zoom Menu In the one window surveillance mode right click mouse click fn Button in the front panel or click AUX key in the remote control The interface is shown as below See _ Figure 6 1 View 1 View 4 View 9 View 16 r aun j Color Setting Search Record Alarm Output Alarm Input Main Menu Figure 6 1 Click Pan Tilt Zoom the interface is shown as in Figure 6 2 Here you can set the following items o Zoom e Focus Oo jris Please click icon l and kl to adjust zoom focus and Iris D PAN TILT ZOOM gt S Zoom P Focus Iris P Set Page Switch Figure 6 2 In _ Figure 6 2 please click direction arrows See _ Figure 6 3 to adjust PTZ position There are totally eight direction arrows Please note there are only four direction arrows in DVR front panel Figure 6 3 6 1 1 3D Intelligent Positioning Key 116 In the middle of the eight direction arrows there is a 3D intelligent p
67. E a 1115 3 4 5 6 Da R5232 La NETWORK CE ALARM Latch 10 sec 17300 Alarm Upload SER oom IV Record Channel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DEFAULT BACKUP Record Latch 15 sec 10 300 amp ADVANCED HDD MANAGEMENT Send Email Show Message EE ONORMALT Y Tour 1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 a Alarm I O Config La Record PTZ Activation Set men al M Capture Pi 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Da AUTO MAINTENANCE MatisEnable u Matrix config ADDTIONAL FUNCTION Anti dither 0 sec 0600 Copy Refresh Figure 7 42 147 Motion Detect Cancel Figure 7 43 Please refer to the following sheet for detailed information Parameter Function There are three types Motion detection video loss Camera Masking Type Select channel name from the dropdown list You need to draw a circle to enable motion detection function Sensitivity There are six levels The sixth level has the highest sensitivity Region e There are six levels The sixth level has the highest sensitivity e Region If you select motion detection type you can click this button to set motion detection zone The interface is shown as in Figure 7 43 There are PAL 22X18 NTSC 22X15 zones Right click mouse you can go to full screen display mode Do remember clicking OK button to save your motion detection zone setup please click save butt
68. Figure 7 33 Please refer to the following sheet for detailed information Parameter Function SMTP Server User Name Password Sender Health mail enable Input server address and then enable this function Input port value here The sender email account user name The sender email account password Sender email address Subject Input email subject here Max 32 digit Address Input receiver email address here Max input three addresses Support SSL encryption mailbox Please check the box here to enable this function This function allows the system to send out the test email to check the connection is OK or not Health mail interval Please check the above box to enable this function and then set the corresponding interval System can send out the email regularly as you set here DDNS The DDNS interface is shown as in _ Figure 7 34 Please make sure your DVR support this function 140 ll Control Panel E Query System Info Ef VERSION Ef HDD INFO E LOG fp System Config GENERAL EN ODE SCHEDULE Reese NETWORK EMAIL 3 DONS MAS MTP ALARM CENTER ALARM DETECT PAN I TILT 200M DEFAULT B4CKUP ADVANCED HOD MANAGEMENT ABNORMITY Alarm 1 0 Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE 4ADOTIONAL FUNCTION DONS Type Server IP Port Domain Marne User Name Password Alive Interval sec DONS Y Enable CH99 DONS 1 1765535 i 130000 Figure 7 34 Please refer to th
69. Japanese French Spanish All languages listed here are optional Slight difference maybe found in various series e HDD full Here is for you to select working mode when hard disk is full There are two options stop recording or rewrite If current working HDD is overwritten or the current HDD is full 83 while the next HDD is no empty then system stops recording If the current HDD is full and then next HDD is not empty then system overwrites the previous files e Pack duration Here is for you to specify record duration The value ranges from 60 to 120 minutes Default value is 60 minutes e DVR No When you are using one remote control not included in the accessory bag to control several DVRs you can give a name to each DVR for your management e Video standard There are two formats NTSC and PAL e Auto logout Here is for you to set auto logout interval once login user remains inactive for a specified time Value ranges from 0 to 60 minutes eo Startup wizard Once you check the box here system will go to the startup wizard directly when the system restarts the next time Otherwise it will go to the login interface e Device ID Please input a corresponding device name here Note Since system time is very important do not modify time casually unless there is a must Before your time modification please stop record operation first After completing all the setups please click save button system goes back to the previous me
70. LEMENTS 187 Vil Welcome Thank you for purchasing our DVR This user s manual is designed to be a reference tool for the installation and operation of your system Here you can find information about this series DVR features and functions as well as a detailed menu tree Before installation and operation please read the following safeguards and warnings carefully Vill Important Safeguards and Warnings 1 Electrical safety All installation and operation here should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation 2 Transportation security Heavy stress violent vibration or water splash are not allowed during transportation storage and installation 3 Installation Keep upwards Handle with care Do not apply power to the DVR before completing installation Do not place objects on the DVR 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair 5 Environment The DVR should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc This series product shall be transported storage and used in the environment ranging from 0 C to 55 C 6 Accessories Be sure to use all the
71. M 1 to ALARM 8 The alarm becomes active in low voltage from the left to the right 1 2 3 4 5 6 7 8 In the first line from There are three groups of normal open activation output on off the left to the right button 1 NO C 2 NO C 3 NO C t m 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders The 16 channel interface is shown as in Figure 3 2 4 3 9 101112 13141516 52 AB OE LTA ai a es a ODODOODO OUD Figure 3 2 AB cable connection Please refer to the following sheet and Figure 3 2 for detailed information In the second line ALARM 1 to ALARM 16 The alarm becomes active in low voltage from the left to the right 1 2 3 4 5 6 7 8 and the first line from the left to the right 9 10 11 12 13 14 15 16 In the first line from There are three groups of normal open activation output on off the left to the right button 3 NO C and the second line from the left to the right 1 NOC 2 NO C o m 48 485 A B 485 communication port They are used to control devices such as PTZ Please parallel connect 120TQ between A B cables if there are too many PTZ decoders 3 8 1 2 1 5U Series Simple 1 5U The 1 5U series product interface is shown as in Figure 3 3 3 E cs E cos 1 ca OF YE A RN ES 25
72. N6 Series Standalone DVR User s Manual Version 4 5 0 Table of Contents 1 FEATURES AND SPECIFICATIONS oococococoncncnnncncncanannnnnnnnncnnannnnnnnnnnnnannnnnanannnas 1 1 1 ONO AA E A IET E 1 1 2 ELO AA 1 1 3 SPECINCAUONS sesidir aar E E tates 2 kor A A A 2 ES to O meee Tene Ra et ac 6 gc Peo IMPI aa 9 ESA A SI PP re MER Pe Ae RW tre nr etn AR ere 12 35 ZW Series CHD SDISEreS cann a A a aiii 16 135 2USeres IDA senes oda 19 2 OVERVIEW AND CONTROLS cccccccccccccncecececececenencececseeeneneucececeeeeeneneueseeaees 23 2 1 Front Fanale a a a a a a a a a 23 2 ISO a neto 23 Ale O O O A eee 24 2 1 3 2U series HD SDI series 960H included ooocooooccnooononooancnonnncnonnnonoononononononononononononoss 26 2 2 A e A A O aaa 29 Zest MUSAS e e e de de 29 A OS A le 29 ae eG IMPI DU ia A E R A es 30 a E NR 31 22 0 2 Series HD SDIS ie 31 2250 ense es IDA SCMeS aaa 32 2 3 COMMEGCION SAM Ia 33 2d HUSOS o o o ode nd bool es nia o in a 33 PEE A O a a A Nee Oe ene ace wee ON Nt a eae 34 Bee SOIC S oc toca saeco sects sacs a Aaa aa dale voatnet va beala aera 35 2304 2U senes AD SUI SEMES ii A td 37 234 2WESEMES 900 SEMES idolo ii ira 37 2 4 Remote Control canes 38 2 5 MOUSe CONTO taa 40 2 6 VIMUal Keyboard Front Panelen ii iio 42 20 1 WARE ODO dada ardid 42 202 IP GON RAM ii iaa 42 3 INSTALLATION AND CONNECTIONS oonccncccocccononcnccconoconononannnnnconanenanenanronanenas 43 3 1 Check Unpack
73. Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Backup 1 11 Curent Page Total Page Figure 5 56 JumpTo 1 113 Click the Details button or double click the log item you can view the detailed information See Figure 5 57 Detailed Information Log Time 2011 03 09 16 03 12 Log Type File operation gt Record Playback Type Record Playback IP Address 10 15 2 187 User admin Channel 10 File Name 2011 03 08 15 00 14 2011 03 08 15 00 14 R Previous Figure 5 57 5 6 4 Version Here is for you to view some version information See Figure 5 58 Channel Alarm in Alarm out System version Build Date 16 16 6 2 606 0000 0 2009 06 18 Figure 5 58 5 6 5 Online Users Here is for you manage online users See Figure 5 59 You can disconnect one user or block one user if you have proper system right Max disconnection setup is 65535 seconds 114 es ONLINE USERS S User Name IP 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 10 6 2 37 Disconnect Block for Figure 5 59 5 7 Shutdown
74. RCA Touring schedule auto control PAL NTSC Real time monitor D1 704x576 704x480 Playback channel 1 16 D1 704x576 704x480 Resolution HD1 704x288 704x240 PAL NTSG BCIF 352x576 352x480 CIF 352x288 352x240 QCIF 176x144 176x120 Support dual streams Extra stream resolution CIF 352X 288 352 X 240 QCIF 176x144 176x120 Quality Audo 1 ch audio output 200 3000mv 5KO BNC 1 ch mi output Output 200 3000mv 5KQ RCA B direcional 1 ch audio talk output 200 3000mv 5KQ BNC 1 ch audio output Audio 200 3000mv 5KQ RCA 2 built in SATA port Support 2 HDDs Hard Disk Audio PCM 28 8MByte h Manual recording motion detection recording schedule recording and Recording alarm recording Mode Priority Manual recording gt alarm recording gt motion detection Record and recording gt schedule recording playback 1 to 120 minutes single record duration Default setup is 60 minutes Length Playback Repeat When hard disk is full system can overwrite previous video file Way Various search engines such as time type and channel Search Playback Various fast play slow play speeds manual frame by frame playback Mode and reverse play mode 10 Various File Can switch to previous or next file or any file in current play list Switch Can switch to file on other channel of the same time If there is a file Ways Support file continuous play when a file is end system auto plays the next file in the curren
75. TA port is broken 4 There is no video output whether it is one channel multiple channel or all channel output There are following possibilities Program is not compatible Please upgrade to the latest version Brightness is 0 Please restore factory default setup There is no video input signal or it is too weak Check privacy mask setup or your screen saver DVR hardware malfunctions 5 Real time video color is distorted There are following possibilities When using BNC output NTSC and PAL setup is not correct The real time video becomes black and white DVR and monitor resistance is not compatible Video transmission is too long or degrading is too huge 168 e DVR color or brightness setup is not correct 6 Can not search local records There are following possibilities HDD ribbon is damaged e HDD is broken e Upgraded program is not compatible The recorded file has been overwritten e Record function has been disabled 7 Video is distorted when searching local records There are following possibilities Video quality setup is too low e Program read error bit data is too small There is mosaic in the full screen Please restart the DVR to solve this problem e HDD data ribbon error HDD malfunction e DVR hardware malfunctions 8 There is no audio when monitor There are following possibilities e It is not a power picker e Itis not a power acoustics e Audio cable is damaged DVR har
76. The dragged zone supports 4X to 16X speeds lt can realize PTZ automatically The smaller zone you dragged the higher the speed a IT Figure 4 39 Here is a sheet for you reference Name Function function Shortcut Function function Shortcut key e key CN Zoom a Near Far Focus ej Near i Je Iris f close m4 Eg Open n_ 4 10Preset Patrol Pattern Scan In Figure 4 37 please click the set button The interface is shown as below See Figure 4 40 Here you can set the following items o Preset e Tour o Pattern e Border PAN TILT ZOOM Function Preset Preset Patrol No 0 Tour Pattern Set Border Del Preset Figure 4 40 In Figure 4 37 click page switch button the interface is shown as in Figure 4 41 Here you can activate the following functions Preset Tour Pattern Auto scan Auto pan Flip Reset Page switch 78 W PAN TILT ZOOM x No 0 Preset Pattern Tour AutoScan AutoPan Flip Reset Page Switch Figure 4 41 Note Preset tour and pattern all need the value to be the control parameter You can define it as you require e You need to refer to your speed dome user s manual for Aux definition In some cases it can be used for special process The following setups are usually operated in the _ Figure 4 37 Figure 4 40 and Figure 4 41 4 9 1Preset Setup In Figure 4 37 use eight direction arrows to adjust camera to the proper position In Fi
77. User user Management Configurable user power No limit to the user or group amount Password Administrator can modify other user s password Five times login failure in thirty minutes may result in account lock Upgrade Web browser client end and update tool Password login protection to guarantee safety User friendly interface when login Provide the following options people can turn off DVR Coon 250 Excuse O General Consumption 25W Exclude HDD Parameter Temperature Humidity 86kpa 106kpa 2U standard industrial case 440 W x460 D x89mm H Weight 6 5 7 5KG Exclude HDD Installation Desktop rack installation Mode 22 2 Overview and Controls This section provides information about front panel and rear panel When you install this series DVR for the first time please refer to this part first 2 1 Front Panel 2 1 1 1U series The front panel is shown as in Figure 2 1 E 000000000000000000000000000000000000000000000000000000000 A O 0000000000000000000000000000000000000000000000000000000_ O Or ooooooooo O0 0 0 00 0 if o 4 a T gt O O41 Os Or Ou OrQuQuOu 20000000000000000000000000000000000000000000000000000000 ZF 000000000000000000000000000000000000000000000000000000000 h Figure 2 1 Please refer to the following sheet for front panel button information Name Icon Power button q Shift Shift In textbox click this button to switch between numeral English Small Capitalized
78. VATS allem AU eee ee eet 119 62 7 BOLE SCD iS 119 6 2 8 Activate Border Function cccccccccccccscecccccecccccccccccecccccacccccueccccuscececaccecuececeeuucececseseecuessenaes 119 029 o a a Sonshine S 119 l WEB GCLIENT OPERATION comandadas 121 7 1 NetWork CONNECTION nin A A Ai aii ida 121 7 2 o A 121 esk FAC AI LINC MONTON anidar idad 124 VEN cll E TAR POS E TN 126 AS GOON cases cde ese Seta ae eek eee ae neo ee 128 tee 4 Pict re Path ana R cord A a eta 128 7 3 A re E O re Pp E EO ener O Deen 129 O TeV SEG Mel MANO Nel ION 130 ae System GOMIQUA IO My A NE 132 E A A A Noe 151 a A A A A vila A 158 7 4 SOAK A A RN 161 LO AMA A A A a 164 7 6 A A A A 165 7 1 LO OU a aa 166 7 8 Un install Web Control ninia aid 166 8 PROFESSIONAL SURVEILLANCE SYSTEM ooccocococnnoncnconanonononononcorananananons 167 9 EAN a 168 APPENDIX A HDD CAPACITY CALCULATION c cccscsececssnececnscececneeeecaeeees 173 APPENDIX B COMPATIBLE BACKUP DEVICE LIST cece eeeeeeeeeeeceeeeees 174 V1 APPENDIX C COMPATIBLE CD DVD DEVICE LIST c ccccccceeeeseeeeeeeeseeeeeeeeees 178 APPENDIX D COMPATIBLE DISPLAYER LIST cccscceeeeeeeeeeeeeseeeeeeeeeeeeeeeees 179 APPENDIX E COMPATIBLE SWITCHER LIST cc eceeeeeceeeeeeeeeeeeeeeeeeeeeenneeeeees 180 APPENDIX F COMPATIBLE WIRELESS MOUSE LIST eeeeeeseeeeeeeeeeeeeees 181 APPENDIX G a 212 ol fe p SS narrar rana 182 APPENDIX H TOXIC OR HAZARDOUS MATERIALS OR E
79. VR and speed dome connection is OK 149 ll Control Panel MIINH dd PO IL ZOOM a Charnel Charne y mien Protocol PELCOD r iy System Config Ades 1 07255 GENERAL ENCODE Baudrate 115200 SCHEDULE R5232 Data Bits MET WORE ALARM DETECT E PANITILT ZOOM DEFAULT BACKLUP ADVANCED HDD MAR AGEMENT ABRNORMITY Alarm IjO Config Record ACCOUNT SHAPSHOT ALTO MAINTENANCE ADOTIORIAL FUNCTION Stop Bits Parity cave Refresh Figure 7 44 Please refer to the following sheet for detailed information Parameter Function You can select monitor channel from the dropdown list Protocol Select the corresponding dome protocol such as PELCOD Address set corresponding dome address Default value is 1 Please note your setup here shall comply with your dome address otherwise you can not control the speed dome Select the dome baud rate Default setup is 9600 Rate Data Bit Default setup is 8 Please set according to the speed dome dial switch setup Stop bit Default setup is 1 Please set according to the speed dome dial switch setup Parity Default setup is none Please set according to the speed dome dial switch setup Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Click this button to get device latest configuration information 7 3 2 9 Default amp Backup Default Restore factory default
80. alog alarm signal to specific alarm output channel Control 4 ch alarm input You 8 ch alarm input You 16 ch alarm input can set normal open or can set normal open or You can set Alarm Input normal close type to normal close type to normal open or select the alarm type select the alarm type normal close type to select the alarm type 3 channel relay output The upper limit for rated current is 800mA Output Alarm Relay 30VDC 2A 125V AC 1A activation alarm USB 2 USB 2 0 ports Interface Interface Network RJ45 10M 100M 1000M self adaptable Ethernet port connection PTZ control port AERC Support various PTZ control protocols RS232 Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network System Hard Disk Display HDD current status Information Information 11 Log Backup to 1024 log files statistics Support various search engines such as time and type Were Display version information channel amount alarm input and output ersion amount system version and release date Display current on line user User Multi lever user management various management modes Management User Integrated management for local user serial port user and network user Manageme Configurable user power i No limit to the user or group amount Administrator can modify other user s password Data Data stream statistics for each channel in wave mode Stream Statistics Authenti
81. an send out the email regularly as you set here Click the Test button you can see the corresponding dialogue box to see the email connection is OK or not See Figure 5 20 Please note system will not send out the email immediately when the alarm occurs When the alarm motion detection or the abnormity event activates the email system sends out the email according to the interval you specified here This function is very useful when there are too many emails activated by the abnormity events which may result in heavy load for the email server EMAIL SMTP Server MailServer Port Anonymous User Name 0 Password Receiver sender Title DVR ALERT Attachment a SSL Enable Event Interval 120 HealthEnable Interval 60 Cancel Figure 5 19 Message Mail Test Error Figure 5 20 5 3 5 9 FIP You need to download or buy FTP service tool such as Ser U FTP SERVER to establish FTP service 94 Please install Ser U FTP SERVER first From start gt program gt Serv U FTP Server gt Serv U Administator Now you can set user password and FTP folder Please note you need to grant write right to FTP upload user See Figure 5 21 Serv U Administrator lt lt Local Server gt gt if lol x File Edit User view Window Help Wx Bolae ts se oe x x FL Serv U Servers E B lt lt Local Server gt gt amp Account 4 General amp Dir Access
82. anagement User Integrated management for local user serial port user and network user Manageme Configurable user power nt Support user group and its corresponding rights modification No limit to the user or group amount ala Password modification Administrator can modify other user s password Authenticati ae Account lock strategy Five times login failure in thirty minutes may result in account lock Upgrade Web browser client end and update tool Password login protection to guarantee safety User friendly interface when login Provide the following options Logout shutdown restart Login Logout and Shutdown General Parameter Right authentication when shut down to make sure only those proper people can turn off DVR Power AC90 264V 50 2 Hz Max 75W Power Consumptio 25W Exclude HDD n Working O a 55 C Temperatur Working 10 90 Humidity Air 86kpa 106kpa Pressure Dimension 1 5U standard industrial case 440 W x410 D x70mm H Weight 4 5 5 5KG Exclude HDD Installation Desktop rack installation Mode 1 3 3 Simple 1 5 U System Compression Standard Main High performance industrial embedded micro controller Processor OS Embedded LINUX System Multiplex operations Multiple channel record multiple channel playback Resources and network operation simultaneously Interface User friendly graphical user interface Devices Method optional Function USB mous
83. arameter System enables auto record function as you set in record schedule setup Manual Enable corresponding channel to record no matter what period applied in the record setup Stop stop current channel record no matter what period applied in the record setup Operation here is the same to chapter 4 2 Manual Record Please refer to chapter 4 2 for detailed information 7 3 3 4 Account Here you can add remove user or modify password See Figure 7 49 154 Configuration Control Panel ES E H B Query System Info aed EA o 7 B VERSION in Ef HDD INFO rallado Add User 888888 Ef LOG pea System Config admin Reuseable GENERAL Modify User ENCODE SCHEDULE R5232 Delete User 23 NETWORK ALARM DETECT Modify Password PAN TILT ZOOM DEFAULT BACKUP ADVANCED HDD MANAGEMENT Add Group ABNORMITY Alarm I O Config Record l amp ACCOUNT Modify Group SNAPSHOT AUTO MAINTENANCE E ADDTIONAL FUNCTION elete Group DNS Refresh Figure 7 49 7 3 3 5 Auto Maintenance Here you can select auto reboot and auto delete old files interval from the dropdown list See Figure 7 50 Co nfiguration Control Panel AUTO MAINTENANCE E E Query System Info E VERSION Auto Reboot System Every Tuesday 02 00 GENERAL ENCODE Auto Delete Old Files SCHEDULE NEWER R5232 NETWORK ALARM DETECT PAN TILT ZOOM ye DEFAULT BACKUP ADVANCED MJ AUTO MAINTENANCE
84. as a A o o a o A Stop Playing Synch Player All Record Y Normal Y Alarm Y Motion Figure 4 12 zz refer to the ao sheet for more information CAE A window 2 type Playback mode and channel selection pane Here is to display the searched picture or file Support 1 4 9 16 window playback Here you can select to search the picture or the recorded file When there is displayed picture on the left pane you can set the corresponding setup Play from the RAW HDI REC PIC eThe blue highlighted date means there is picture or file Otherwise there is no picture or file e n any play mode click the date you want to see you can see the corresponding record file trace in the time bar Playback mode 1 4 9 16 It may vary due to different series In 1 window playback mode you can select 1 16 channels In 4 window playback mode you can select 4 channels according to your requirement In 9 window playback mode you can switch between 1 9 and 10 16 channels In 16 window playback mode you can switch between1 16 and 17 32 channels The time bar will change once you modify the playback mode or the channel option 61 Double click it you can view the picture record file list of current day O The file list is to display the first channel of the record file The system can display max 128 files in one time Use the A V or the mouse to File list view the file Select one item and then double click
85. as type day Files dav Figure 7 62 Now you can see system begins download and the download button becomes stop button You can click it to terminate current operation At the bottom of the interface there is a process bar for your reference Please refer to the following sheet for detailed information Type Function Type Search general record alarm record and motion detection record Search alarm record Search motion detection record Detection Search local record Snapshot Search snapshot file Search card file Item Begin Set the file start time You can select from the dropdown time list Set the file end time You can select from the dropdown list Select the channel from the dropdown list Operation Search Click this button you can view the recorded file matched your requirements There are 100 files in one screen You can use pg up down button to view more files Select the file first and then click playback button to view the video Download Download by file Select the file s and then click type download button Download by time Download the recorded file s within your specified period Download Select the file you need multiple choices and then click download button you can see system pops up a dialogue box See Figure 7 55 Input the downloaded file name specify the path and then click OK button You can see system begins download and the download becomes stop button There is a progre
86. axial cable to the PTZ device RS485 is a single direction protocol the PTZ device can t return any data to the unit To enable the operation connect the PTZ device to the RS485 A B input on the DVR See Figure 3 8 Since RS485 is disabled by default for each camera you must enable the PTZ settings first This series DVRs support multiple protocols such as Pelco D Pelco P To connect PTZ devices to the DVR 52 1 Connect RS485 A B on the DVR rear panel 2 Connect the other end of the cable to the proper pins in the connector on the camera 3 Please follow the instructions to configure a camera to enable each PTZ device on the DVR 3 11 Other Interfaces There are still other interfaces on the DVR such as USB ports You can refer to the Figure 3 6 for more information USB Port RS232 RS485 PTZ Control Power Switch z 2 E 2 lt z o e gt Network Switch Power Input Online User Online User Online User Network Keyboard Online User 1U series 53 Gr RS485 PTZ Control Power Switch Power Input USB Port Network Switch Online User Online User Online User Network Keyboard Online User 1 5U Series a oP RS485 PTZ Control Power Switch gt gt fe 0 Power Input ddr 4 mec iw AS 1114450704 FMM S Ms eSATA USB Port Network Switch Online User Online User Online User Network Keyboard Online User 2U Series Figure 3 6
87. ay result in relay damage Please use the co contactor to realize the connection between the alarm output port and the load 3 How to connect PTZ decoder a Ensure the decoder has the same grounding with DVR otherwise you may not control the PTZ Shielded twisted wire is recommended and the shielded layer is used to connect to the grounding b Avoid high voltage Ensure proper wiring and some thunder protection measures c For too long signal wires 1200 should be parallel connected between A B lines on the far end to reduce reflection and guarantee the signal quality d 485 A B of DVR cannot parallel connect with 485 port of other device e The voltage between of A B lines of the decoder should be less than 5v 4 Please make sure the front end device has soundly earthed Improper grounding may result in chip damage 3 8 1 Alarm Input and Output Details You can refer to the following sheet for alarm input and output information Important Please refer to the specifications for the alarm input and output channel amount Do not merely count the alarm input and out channel amount according to the ports on the rear panel 3 8 1 1 1U Series The 4 8 channel series product interface is shown as below See Figure 3 1 47 AB cable connection Figure 3 1 Please refer to the following sheet and Figure 3 1 for detailed information In the second line ALAR
88. back mode you can select any Enlargement zone to activate partial enlargement function Backup HDD backup function Support peripheral USB backup device Flash disk portable disk Backup Mode USB burner and etc Support peripheral eSATA backup device Support network download and backup View monitor channel remotely DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance Pala View alarm information such as external alarm motion detection and video loss via client Network Support network PTZ lens control control File download backup and playback Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Detection Various sensitivity levels Motion Detection and Alarm Alarm can activate record or external alarm or screen message prompt message in specified period Control Support analog alarm signal to specific alarm output channel 14 6 channel 6 channel 6 channel 5 channel 5 channel relay relay relay relay relay output output output output output including including including includin includin Alarm Output ere ane ane Bae 9 ene 9 controllable controllable controllable controllable controllable DC 12V DC 12V DC 12V D
89. cati ae Account lock strategy Five times login failure in thirty minutes may result in account lock Upgrade Web browser client end and update tool Password login protection to guarantee safety User friendly interface when login Provide the following options Logout shutdown restart Right authentication when shut down to make sure only those proper people can turn off DVR DC 12V Power General Consumptio Parameter Login Logout and Shutdown lt 25W Include adapter Exclude HDD n Working OC 1096 Temperatur e Working 10 90 Humidity Air 86kpa 106kpa Pressure 1 5U standard industrial case 440 W x410 D x70mm H Weight 3 9 4 5KG Exclude HDD Installation Desktop Mode 1 3 4 2U Series MA High performance industrial embedded micro controller System Processor Embedded LINUX system Multiplex operations Multiple channel record multiple channel Resources playback and network operation simultaneously User friendly graphical user interface Input Devices Front panel USB mouse remote control Arabic number English character donation and extension Chinese Input Method optional Shortcut Copy paste operation USB mouse right key shortcut menu double Function click USB mouse to switch screen 12 Compression MIOS Compression i 4 CH 8 CH 16 CH 24H 32H composite composite composite composite composite video input video input video input video input video input V
90. ce soft cable and its section shall be more than 4mm2 184 e The monitor system usually can adopt the one point ground Please connect the ground end of 3 pin socket in the monitor system to the ground port of the system protection ground cable 4 The shortcut way to check the electric system using the digital multimeter For 220V AC socket from the top to the bottom E ground cable N neutral cable L live cable Please refer to the following figure A ES E There is a shortcut way to check these thee cables connection are standard or not not the accurate check Importance In the following operations the multimeter range shall be at 750V For E earth cable Turn the digital multimeter to 750V AC use your one hand to hold the metal end and then the other hand insert the pen to the E port of the socket See the following figure If the multimeter shows 0 then you can see current earth cable connection is standard If the value is more than 10 then you can see there is inductive current and the earth cable connection is not proper 185 For L live cable Turn the digital multimeter to 750V AC use your one hand to hold the metal end and then the other hand insert the pen to the L port of the socket See the following figure If the multimeter shows 120 then you can see current live cable connection is standard If the value is less than 60 then you can see current live cable connection is not proper or it is n
91. ck Click the snapshot button in the full screen mode the system can snapshot 1 picture per second Olt is to display the record type and its period in current search criteria ein 4 window playback mode there are corresponding four time bars In other playback mode there is only one time bar Use the mouse to click one point of the color zone in the time bar system begins Time bar piayoack A O The time bar is beginning with O o clock when you are setting the configuration The time bar zooms in the period of the current playback time when you are playing the file eThe green color stands for the regular record file The red color stands for the 9 external alarm record file The yellow stands for the motion detect record file eThe option includes 24H 12H 1H and 30M The smaller the unit the larger the 62 unit zoom rate You can accurately set the time in the time bar to playback the record O The time bar is beginning with O o clock when you are setting the configuration The time bar zooms in the period of the current playback time when you are playing the file Select the file s you want to backup from the file list System max supports files from four channels Then click the backup button now you can see the backup 10 Backup menu Click the start button to begin the backup operation Check the file again you can cancel current selection System max supports to display 32 files from one channel lt is t
92. close type to normal open or select the alarm type select the alarm type normal close type to select the alarm type Alarm 3 channel relay output Output Alarm Relay 30V DC 2A 125VAC 1A activation alarm USB 2 USB 2 0 ports Interface Interface Alarm Input Network RJ45 10M 100M 1000M self adaptable Ethernet port connection PTZ control port EROS Support various PTZ control protocols RS230 Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network Hard Disk Display HDD current status Information Stream Statistics statistics Support various search engines such as time and type ersion amount system version and release date On line user User Multi lever user management various management modes Management User Integrated management for local user serial port user and network user Manageme Configurable user power i No limit to the user or group amount Administrator can modify other user s password Authenticati Five times login failure in thirty minutes may result in account lock User friendly interface when login Provide the following options Logout shutdown restart Right authentication when shut down to make sure only those proper people can turn off DVR DC 12V System Information Login Logout and Shutdown a Power enera i Parameter po Pt lt 2sw With adapter exclude HDD Working OCL Temperat
93. cords of channels 17 to 32 are stored into the hard disk s which belong to HDD Group NO 2 Important Once you change the HDD Group settings system will pack the records and snapshots and then reboot A Channels Setting Channel MABE OUEL ik iE E LELE HDD Group NO 1 Cancel Figure 5 37 g gt Channels Setting Channel E E E T A E E EE E EE HDD Group NO 2 7 Figure 5 38 5 5 2 Abnormity Abnormity interface is shown as in Figure 5 39 Event type There are several options for you such as disk error no disk disconnection IP conflict MAC conflict and etc e Alarm output Please select alarm activation output port multiple choices e Latch Here you can set corresponding delaying time The value ranges from 10s 300s System automatically delays specified seconds in turning off alarm and activated output after external alarm cancelled e Show message system can pop up the message in the local screen to alert you when alarm occurs e Alarm upload System can upload the alarm signal to the network including alarm centre if you enabled current function e Send email System can send out email to alert you when alarm occurs e Buzzer Highlight the icon to enable this function The buzzer beeps when alarm occurs 104 Event Type No Disk Enable A BM Alarm Out ka Latch Show Message Alarm upload Send Bhail Cancel Figure 5 39 5 5 3 Alarm Output Here is for you to set proper alarm o
94. ctivate external alarm or screen message prompt External Support record activation function or activate external alarm or screen Alarm message in specified period Manual Enable or disable alarm input channel Alarm Support analog alarm signal to specific alarm output channel Control type to select the alarm type 6 channel relay output including one controllable DC 12V output port Output Alarm Relay 30V DC 2A 125V AC 1A activation alarm USB 2 USB 2 0 ports Interface Interface Network RJ45 10M 100M 1000M self adaptable Ethernet port connection PTZ control port iad Support various PTZ control protocols 4 ch alarm input You 8 ch alarm input You 16 ch alarm input can set normal open or can set normal open or You can set Alarm Input normal close type to normal close type to normal open or select the alarm type select the alarm type normal close RS232 Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network System Hard Disk Display HDD current status Information Information Data Data stream statistics for each channel in wave mode Stream Statistics Log Backup to 1024 log files statistics Support various search engines such as time and type Versi Display version information channel amount alarm input and output ersion amount system version and release date Display current on line user User Multi lever user management various management modes M
95. d the three to five seconds video before activating the record operation into the file Depends on data size Setup e In _ Figure 7 29 click set button you can go to the corresponding setup interface e Please set schedule period and then select corresponding record or snapshot type schedule snapshot motion detection snapshot and alarm snapshot e Please select date Current setup applies to current day by default You can draw a circle before the week to apply the setup to the whole week e After complete setup please go back to Figure 7 29 and then click save to save current time period setup Copy It is a shortcut menu button You can copy current channel setup to one or more all channels The interface is shown as in Figure 7 28 Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Click this button to get device latest configuration information 7 3 2 4 RS232 The RS232 interface is shown as in _ Figure 7 31 137 ll Control Panel Query System Info Ef VERSION AS232 COM COM 01 x EJ a Function Console Ef Los E System Config Data Bits Bs GENERAL ENCODE Stop Bits tw SCHEDULE e Baudrate 115200 Saas Paw None DETECT PAN TILT 200M DEFAULT BACKLUP ADVANCED HOD MANAGEMENT ABNORMITY Alarm 1 6 Config Record ACCOUNT SMAPSHOT AUTO MAINTENANCE 400TICNAL FUNCTION DNS Save Refresh Figur
96. d then click save button or you can finish all setup and then click save button to memorize all the settings 4 5 1 2 Redundancy Redundancy function allows you to memorize record file in several disks When there is file damage occurred in one disk there is a spare one in the other disk You can use this function to maintain data reliability and safety In the main menu from Setting to Schedule you can highlight redundancy button to enable this function See Figure 4 14 In the main menu from Advanced to HDD management you can set one or more disk s as redundant You can select from the dropdown list See Figure 4 15 System auto overwrites old files once hard disk is full Please note only read write disk or read only disk can backup file and support file search function so you need to set at least one read write disk otherwise you can not record video Note About redundancy setup e lf current channel is not recording current setup gets activated when the channel begin recording the next time e f current channel is recording now current setup will get activated right away the current file will be packet and form a file then system begins recording as you have just set After all the setups please click save button system goes back to the previous menu al HDD MANAGE Alarm Set HDD Setting Alarm Release Channels Setting HDD No 1 v Setto Read Write 7 Execute Type Read Write Status Normal Capacity 232
97. ddress in the WAN from the IP address column Note After PPPoE successful dial you need to go to the device local end to get device current IP address and then use the client end to access this IP address Configuration Control Panel gt Advance Bf Query System Info B VERSION Service MULTICAST Ef HDD INFO EY LOG User IP Address 239 255 42 42 aI System Config Password So Port 36666 1 65500 GENERAL ENCODE SCHEDULE R5232 NETWORK advance EMAIL DDNS NAS NTP ALARM CENTER UPNP ALARM DETECT La PAN TILT ZOOM La DEFAULT BACKUP amp ADVANCED La HDD MANAGEMENT ag ABNORMALITY Ez Alarm I O Config La Record fa ACCOUNT SNAPSHOT Save Refresh La AUTO MAINTENANCI 3 ADDTIONAL FUNCTION CARD OVERLAY Ll v la lt Figure 7 38 144 UNPN Go to the UPnP interface you can see an image is shown as in Figure 3 39 It allows you to establish the mapping relationship between the LAN and the public network Here you can also add modify or remove UPnP item Configuration ll Control Panel BF Query System Info af VERSION E HDD INFO EY LOG 4 System Config a GENERAL La ENCODE SCHEDULE R5232 Ea NETWORK Advance EMAIL DDNS NAS NTP ALARM CENTER lt UPNP Ea ALARM 3 DETECT PAN TILT ZOOM DEFAULT BACKUP amp ADVANCED a HDD MANAGEMENT ABNORMALITY Alarm I O Config Ez Record ACCOUNT SNAPSHOT AUTO MAINTENANCI ADDTIONAL FUNCTION Ea CARD OVERLAY lt
98. device shall be in auto record mode Chapter 4 4 Schedule Record System can delay the record for specified time after alarm ended The Latch value ranges from 10s to 300s Email Please draw a circle to enable email function System can send out email to alert you when alarm occurs and ends 146 Tour Display the selected video in local monitor window nil Tour interval and tour mode are set in DVR local menu chapter 5 3 9 Display PTZ Here you can set PTZ movement when alarm occurs Such as go to activation preset x when there is an alarm The PTZ configuration events include preset tour and pattern You need to input capture channel number so that system can backup snapshot file when alarm occurs Copy It is a shortcut menu button You can copy current channel setup to one or more all channels Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Click this button to get device latest configuration information 7 3 2 Detect Analysis the video system enable motion detection alarm when it detects the motion signal reached the specified sensitivity The detection interface is shown as in Figure 7 42 Configuration Control Panel DETECT E Query System Info Event Type Motion Detect BP VERSION f HDD INFO Channel Channel 01 DA Y Sensitivity 3 y Bf LOG F System Config Region Select GENERAL ENCODE Period Set SCHEDUL
99. dware malfunctions 9 There is audio when monitor but there is no audio when system playback There are following possibilities e Setup is not correct Please enable audio function e Corresponding channel has no video input Playback is not continuous when the screen is blue 10 Time display is not correct There are following possibilities e Setup is not correct e Battery contact is not correct or voltage is too low e Crystal is broken 11 DVR can not control PTZ There are following possibilities e Front panel PTZ error PTZ decoder setup connection or installation is not correct e Cable connection is not correct e PTZ setup is not correct e PTZ decoder and DVR protocol is not compatible 169 PTZ decoder and DVR address is not compatible When there are several decoders please add 120 Ohm between the PTZ decoder A B cables furthest end to delete the reverberation or impedance matching Otherwise the PTZ control is not stable The distance is too far 12 Motion detection function does not work There are following possibilities Period setup is not correct Motion detection zone setup is not correct Sensitivity is too low For some versions there is hardware limit 13 Can not log in client end or web There are following possibilities For Windows 98 or Windows ME user please update your system to Windows 2000 sp4 Or you can install client end software of lower version Please note right now our DVR
100. e 89 Here is a sheet for your time zone setup Brazil Brazil NTPServer 123 GMT 08 00 v 10 Cancel Figure 5 13 5 3 5 4 Multiple Cast Setup Multiple cast setup interface is shown as in Figure 5 14 X Cancel Figure 5 14 Here you can set a multiple cast group Please refer to the following sheet for detailed information e P multiple cast group address 224 0 0 0 239 255 255 255 D address space 90 e The higher four bit of the first byte 1110 e Reserved local multiple cast group address 224 0 0 0 224 0 0 255 TTL 1 When sending out telegraph For example 224 0 0 1 All systems in the sub net 224 0 0 2 All routers in the sub net 224 0 0 4 DVMRP router 224 0 0 5 OSPF router 224 0 0 13 PIMv2 router e Administrative scoped addressees 239 0 0 0 239 255 255 255 Private address space Like the single broadcast address of RFC1918 e Can not be used in Internet transmission Used for multiple cast broadcast in limited space Except the above mentioned addresses of special meaning you can use other addresses For example Multiple cast IP 235 8 8 36 Multiple cast PORT 3666 After you logged in the Web the Web can automatically get multiple cast address and add it to the multiple cast groups You can enable real time monitor function to view the view Please note multiple cast function applies to special series only 5 3 0 0 PPPOE PPPoE interface is shown as in Figure 5 15 Input
101. e 7 31 Please refer to the following sheet for detailed information Parameter Function RS232 There are two options COM 01 and keyboard Function Console is to upgrade the program or debug via COM or mini terminal software Keyboard COM control protocol You can use keyboard to control DVR via COM Data Bit The value ranges from 5 to 8 Stop Bit There are three options 1 2 Baud Bit You can select corresponding baud bit here Parity There are five options none odd even space mark System default setup is Function Console Data bit 8 Stop bit 1 Baud bit 115200 Parity None 7 3 2 5 Network Network interface is shown as in _ Figure 7 32 138 Configuration xX E Control Panel A SYSTEM CONFIGS A d Subnet Mask 2558 255 0 0 hu ADVANCE pu ALARM i ve DETECT E e ADVANCED z ABNORMALITY fun ALARM I O CONFIG i ve Record ACCOUNT SNAPSHOT me AUTO MAINTENANCE Figure 7 32 Please refer to the following sheet for detailed information Network Mode Includes multiple access fault tolerance and load balancing Default Network Please select ethO eth1 bondO optional after enable multiple Card access function Ethernet Please select eth0 eth1 optional after enable multiple access function Note 960H series support the above three configurations and supports functions as multiple access fault tolerance and load balancing TCP Port Default value
102. e and and then turn the screws in power cable firmly 7 Put the cover in accordance 8 Secure the screws in the with the clip and then place the rear panel and the side panel upper cover back 3 3 2 1 5U series This series DVR has four SATA HDDs Please use HDD of 7200rpm or higher 1 Loosen the screws of the 2 Line up the HDD to the four upper cover holes of the HDD bracket 4 Unfasten the HDD power 5 Use the special data cable to 6 Insert the HDD power cable cable connect the HDD and the SATA Close the chassis and fix the port screws to secure firmly 3 3 3 2U series HD SDI series 960H gt This series DVR max supports 8 SATA HDDs Please use HDD of 7200rpm or higher 1 Loosen the screws of the 2 Remove the HDD upper 3 Now you can see the bottom upper cover bracket bracket 5 Use screws to fix HDD 4 Line up the HDD to the the HDD 6 Install the upper bracket and then Use screws to fix HDD in the of holes four bracket bracket 7 Unfasten the HDD power 8 Insert the HDD power 9 Use the special data cable to cable cable connect the HDD and the SATA port Close the chassis and fix the screws to secure firmly Important lf the HDD amount is less than four you do not need to install the HDD bracket When there is a bracket please make sure the installation direction of HDDs is the same 3 4 Rack Installation Please note this installatio
103. e connected at the same port Since there is only one common port there is no circuit and so there is no interference Sub system Sub system Sub system Or device 1 Or device 2 Or device 3 cd Ea A System or sub system Shielded earthing point 4 _ __ Cable 7 Sub system Sub system Main power Or device 4 P Or device N Multiple point ground In the following figure you can see the internal circuit uses the chassis as the common point While at the same time all devices chassis use the earthing as the common port In this connection the ground structure can provide the lower ground resistance because when there are multiple point grounds each ground cable is as short as possible And the parallel cable connection can reduce the total conductance of the ground conductor In the high frequency circuit you need to use the multiple point ground mode and each cable needs to connect to the ground The length shall be less than the 1 20 of the signal wavelength 183 Device Safety Earthing SIA LILI AP APTA Device Earthing Mixed ground The mix ground consists of the feature of the one point ground and multiple point ground For example the power in the system needs to use the one point ground mode while the radio frequency signal requires the multiple point ground So you can use the following figure to earth For the direct current DC the capacitance is open circuit and the circuit is one poi
104. e following sheet for detailed information NAS Parameter Your self defined domain name The user name you input to log in the server The password you input to log in the server Interval e Device sends out alive signal to the server regularly e You can set interval value between the device and DDNS server here NAS interface is shown as in Figure 7 35 Please make sure your DVR support this function Save Refresh Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function The private DDNS protocol means you use your self defined private protocol to realize DDNS function DDNS server IP address DDNS server port 141 ll Control Panel NAS an Query Systemn Info Y NAS Enable FTP Mode B VERSION 5 Server IP 0 0 0 0 Port 0 65535 Sef HDD INFO ES LOG User Name File Size KB MB 7 System Config GENERAL ENCODE Remote Path SCHEDULE Period Info ay Channel Channel01 Ml Regular ES MD Bilam EMAIL Ve DDNS E NAS Ca ALARM CENTER ALARM DETECT Tue Set PAN TILT ZOOM DEFAULT BACKUP ADVANCED Da HDD MANAGEMENT Thu Set ABNORMITY Alarm IjO Config Fri Set Record SNAPSHOT AUTO MAINTENANCE E ADDTIONAL FUNCTION En Save Refresh Password Figure 7 35 Please refer to the following sheet for detailed information Parameter Function NAS enable Please select network storage protocol and then enable NAS
105. e to switch screen Video Compressio H 264 n Audio Compressio G 711A n 4 CH composite video 8 CH composite video 16 CH composite input NTSC PAL input NTSC PAL video input BNC 1 0Vp p 750 BNC 1 0Vp p 750 NTSC PAL BNC 1 0Vp p 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output 1 ch VGA output 1 ch HDMI output 1 ch matrix output Support TV VGA HDMI video output at the same time Video erandara PAL 625 line 50f s NTSC 525 line 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s Record per channel Speed Video 1 4 wndows Optional 1 4 8 9 windows 1 4 8 9 16 windows Partition Video Input Video Output Privacy Support one privacy mask of user defined size in full screen mask Support max 4 zones mae Channel information time information and privacy mask zone Information TV Adjust TV Adjust Adjust TV output zone suitable to anamorphic video Cover secret channel with black screen though system is encoding Lock normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection status are shown on the bottom left of display screen Color Hue brightness contrast saturation and gain setup for each channel a Audio Adoni 4 ch 200 2000mv 8 ch 200 2000mv 4 ch 200 2000mv PUT 10KQ BNC 10KQ BNC 10KQ
106. ed DVRs 43 3 2 About Front Panel and Real Panel seeesseccsssocessoccsssoceesoccessocessoccescocessoccesoocessoccessocesssocsssocessseseso 43 3 3 HDD Instalati oNsnssrn a aa a aa 43 SS OS 43 oe WED ONES so 44 3 3 3 2U series HD SDI series 960H ooo A E E AE EA 44 3 4 Rack TNS teal UO css ii 45 3 5 GOMMECUING POWE SUD DIY rsispas tbs tii cacas 45 3 6 Connecting Video Input and Output Devices oooccconoccconoccconoccconoccconacononaconinaconinaconinaconinaconinacaness 45 361 GONMECHnO VASO NP a es Bush eo od 46 30 2 CONNECIING VIGO OU oca 46 3 7 Connecting Audio Input amp Output Bidirectional Audio ooooooooooomoss 46 Safa A o O ween aaaatt 46 Ole AU OUND UE sacs esecia cee ccc cits E ai 46 3 8 Alarm Inputand Output CONOCIO Mais aeaea aasia 47 Sock Alarm mp tand Quiput De Sia a 47 30 2 Alarm MOUT PO arae sl cneaseedvantusta apne cbeele st shige tases bacntort ateealasl me ntes tse esta mpases 51 38683 Alam CUTOUT PO diiniita 52 11 3 9 ROZOZ aaa ecc 52 O A reat E EEA E ATESA EEA N EES 52 STi Other Menas n AAE ASEE EET EAS AEE 53 4 OVERVIEW OF NAVIGATION AND CONTROLS ooccnccconcccnnncnnnnccnnancnnancnnanonnanos 55 4 1 LONI SOG OUT es MaN Men s eces rete eet aceeetec tact eet eee etaecest 55 Adel A E A E A 55 e A MaMe ances ntti ener Selec A EE nerd tatestion E i seaa Bannan eaeacne neces 56 ATS A all ncaa lites Pade Seth lao ial Sl toa Ted eats alt Nan Let ast asd 56 4 1 4 Auto Resume after Pow
107. ed to set the source IP destination IP sometimes you need to input corresponding port number CARD OVERLAY Sniffer Mode NET y Protocols ATM POS bd Setting ATM POS Overlay Mode Preview MEncode Overlay Channel LeftTop Cancel Figure 5 49 Without the protocol For the ATM POS without the protocol the interface is shown as in Figure 5 50 Source IP refers to host IP address that sends out information usually it is the device host Destination IP refers to other systems that receive information Usually you do not need to set source port and target port There are total four groups IP The record channel applies to one group optional only Six frame ID groups verification can guarantee information validity and legal 110 A o ATM POS Data Group Data Group1 Source IP 10 O E eS Port 0 Destination IP 0 6 Ec 25 Port 0 Record Channel startPosition Length Key Frame ID1 1 1 bank Frame ID2 Frame ID3 Frame ID4 Frame ID5 Frame ID6 Cancel Figure 5 50 Click Data button you can see an interface is shown as in Figure 5 51 Here you can set offset value length title according to your communication protocol and data package StanPosition Length Title Field1 5 10 card Field2 1 0 Field3 1 0 Field4 1 0 Cancel Figure 5 51 5 5 10 Config File Backup The configuration file backup interface is shown as below See Figure 5 52 This function allows you to copy current system c
108. em Config GENERAL ENCODE SCHEDULE R5232 NETWORK ALARM DETECT La PAN TILT ZOOM DEFAULT BACKUP amp ADVANCED HDD MANAGEMENT ABNORMALITY Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE ADDTIONAL FUNCTION CARD OVERLAY Auto Register Preferred DNS Tice All Start Time End Time User Logout User Logout User Logout User Logout User Logout User Login User Logout User Login Record Sea User Logout Video Loss Video Loss Video Loss Video Loss Video Loss Wideo Loss User Login Video Loss Video Loss User Logout User Logout Video Loss Desert Can 2011 414 2011 415 k a 2011 04 14 12 16 09 2011 04 14 12 24 19 2011 04 14 12 24 34 2011 04 14 13 24 49 2011 04 14 13 24 49 2011 04 14 13 25 54 2011 04 14 13 25 54 2011 04 14 13 26 09 2011 04 14 13 27 24 2011 04 14 13 27 49 2011 04 14 13 28 29 2011 04 14 14 04 29 2011 04 14 14 04 29 2011 04 14 14 04 29 2011 04 14 14 04 44 2011 04 14 14 12 09 2011 04 14 14 12 34 2011 04 14 14 12 49 2011 04 14 14 25 59 2011 04 14 14 34 24 2011 04 14 14 44 34 2011 04 14 15 14 14 2011 NA 14 15 99 94 Page Down LOG 12 16 12 16 More Detail Search User logged out lt 888888 gt User logged out lt admin gt User logged out lt admin gt User logged out lt 111 gt User logged out lt admin gt User logged in 10 15 2 42 gt User logged out lt admin gt User logged in 10 15 2 4
109. eo transmission Try to avoid interference dry joint loose contact and it shall be away from high tension current 3 7 2 Audio Output The audio output signal parameter is usually over 200mv 1KQ BNC It can directly connect to low impedance earphone active sound box or amplifier drive audio output device 46 lf the sound box and the pick up cannot be separated spatially it is easy to arouse squeaking In this case you can adopt the following measures Use better sound pick up with better directing property e Reduce the volume of the sound box Using more sound absorbing materials in decoration can reduce voice echo and improve acoustics environment e Adjust the layout to reduce happening of the squeaking 3 8 Alarm Input and Output Connection Please refer to the following sheet for alarm input and output connection There are two alarm input types for you to select normal open NO and normal close NC 1 Alarm input a Please make sure alarm input mode is grounding alarm input b Grounding signal is needed for alarm input c Alarm input needs the low level voltage signal d Alarm input mode can be either NC normal Open or NO Normal Close e When you are connecting two DVRs or you are connecting one DVR and one other device please use a relay to separate them 2 Alarm output The alarm output port should not be connected to high power load directly It shall be less than 1A to avoid high current which m
110. er Failure ocooooncconocnnonooncnonaonnncnnonnnnnnnononcnnononccnnnnnncnnnnncnnonannos 57 AAs Replace BUON Bate asar cs ir ic El oa 57 4 2 UNE VIEWING race ia illa 57 4 3 Manta rocoso lo io tit Il AE 58 4 4 SEWON A Pla Dact a a e ees seh eae cceat tvaeua aed cetea cet 60 4 5 e A mE er Pen ee Ore nN eran tee 64 iPr Ba Merve gf CAS MM A ee ene eer es 64 45 2 SOS ON assess ee ake gal A 65 Mo MAGS FIE coon AN 67 4 5 4 Snapshot Disk For special series only ooooooccnoonoccnonocncononanccononancconnnncconnnnccnnnncnnnnnnnos 68 4 6 PS arna E N ER E E EE E A 69 toor 16 1 0 ei EM Miane E E E E E E E 69 AS MONON DES T aiaieeeadens 69 De Oe AOC ONO LL PRA ROA UU E o o O 71 AD AS A EAEE 71 4 7 Alarm Setup and AlarmiAclivatlO anita iles 72 A GOTO laa SUMMA aos ess T2 A A 172 111 4 8 BACKUP a RR a ERE mR RYO 74 Fee peas SS A RO 74 ROT BACKUS ena nn re CEES re eee 74 4 9 PTZ CONTO ana Color SOU aos 76 Ae Toae Coneco Uae Ree RoR Ree eeIU O 76 A ASS O a ere a 76 4 8 3 3D IMeligent POSITIONING Ke Visas TA ACTO Preset Patrol Patern SON a teks Saeed a SOA NTT 78 ESMAS ES QU aa E E ARA AAA A 79 A 8X BW AVES HK Son OS Re Me en ee TC A PR 79 49 3 Patrol setup Tour A A 79 Ae TAC ALS IH AION MOE onere N E into 80 4 95 A scas aaa Sait banshee a ance Sew TAA SA se 80 4 96 ACIIVale Pattern UNC OM nar esi th ese e aos ao e e ina Sid eee 80 AA AUO O NS de e Tn ee 80 ADS Activate Auto oC ri 80 4 11 Pl SS Ss 80
111. erence Name Function Function Function Function key key Right Limit Preset 1 Add Delete Auto T our p Add Delete Delete Group Pattern 1 Start Record Stop Record Delete Assistant ELC Figure 7 12 7 2 2 4 Auto Scan In Figure 7 12 move the camera to you desired location and then click left limit button Then move the camera again and then click right limit button to set a right limit 7 2 2 5 Pattern In Figure 7 12 you can input pattern value and then click start record button to begin PTZ movement Please go back to Figure 7 11 to implement camera operation Then you can click stop record button Now you have set one pattern 7 2 2 6 Preset In Figure 7 12 move the camera to your desired location and then input preset value Click add button you have set one preset 7 2 2 7 Auto tour In Figure 7 12 input auto tour value and preset value Click add button you have added one preset in the tour Repeat the above procedures you can add more presets in one tour 7 2 2 8 Assistant 127 You can select the assistant item from the dropdown list See Figure 7 13 7 2 2 9 Matrix This series product supports matrix extension function You can control the video input and output switch 7 2 2 10 Light and wiper If your PTZ protocol supports the light and wiper control function You can enable disable the light or the wiper set PTZ Auto Scan Left Limit Right Limit Preset p Add De
112. eries does not support this function 960H series only supports single window spot tour Ga VIDEO MATRIX Enable Tour Interval 5 All E View 1 1213441516171819 0A 1A114116 R Default Cancel Figure 5 47 5 5 9 Card Overlay The card overlay function is for financial areas It includes Sniffer information analysis and title overlay function The Sniffer mode includes COM and network 5 5 9 1 COM Type The COM interface is shown as below See Figure 5 48 Protocol Please select from the dropdown list e Setting Click COM setting button the interface is shown as in RS232 interface Please refer to Chapter 5 3 4 RS232 e Overlay channel Please select the channel you want to overlay the card number 109 e Overlay mode There are two options preview and encode Preview means overlay the card number in the local monitor video Encode means overlay the card number in the record file e Overlay Position Here you can select the proper overlay position from the dropdown list CARD OVERLAY Sniffer Mode COM Protocols NONE Setting Com Setting Overlay Channel Overlay Mode Preview Encode Overlay Position LeftTop v Cancel Figure 5 48 5 5 9 2 Network Type The network type interface is shown as below See Figure 5 49 Here we take the ATM POS protocol to continue There are two types with or without the protocol according to clients requirements With the protocol For ATM POS with the protocol you just ne
113. ervancy 1 2 Features This series product has the following features eo Real time monitor It has analog output port VGA port and HDMI port You can use monitor or displayer to realize surveillance function System supports TV VGA HDMI output at the same time e Storage function Special data format to guarantee data security and can avoid vicious data modification e Compression format Support multiple channel audio and video An independent hardware decodes the audio and video signal from each channel to maintain video and audio synchronization eo Backup function Support backup operation via USB port such as flash disk portable HDD burner Client end user can download the file to local HDD to backup via network e Record playback function Support each channel real time record independently and at the same time it can support search forward play network monitor record search download and etc Support various playback modes slow play fast play backward play and frame by frame play Support time title overlay so that you can view event accurate occurred time Support specified zone enlargement eo Network operation Support network remote real time monitor remote record search and remote PTZ control eo Alarm activation function Several relay alarm outputs to realize alarm activation and on site light control The alarm input port and output has the protection circuit to guarantee device safety e Communication po
114. fore the cursor m WY One window monitor mode click this button to display assistant function PTZ control and image color Assistant F Backspace function in numeral control or text control press it 27 In motion detection setup working with Fn and direction keys to realize setup In text mode click it to switch between numeral English character small capitalized and etc In HDD management interface you can click it to switch HDD record information and other information Menu prompt Realize other special functions Various fast soeeds and normal playback In playback mode playback the previous video In normal playback or pause mode click this button to reverse playback In reverse playback click this button to pause playback Fast play Play previous Reverse Pause In playback mode playback the next video In menu setup go to down ward of the dropdown list Play Next Play Pause Window switch In normal playback click this button to pause playback In pause mode click this button to resume playback Click it to switch one window multiple window In real time monitor mode it works as left right direction key Playback mode counter clockwise to forward and clock wise to backward Up down direction key Playback mode turn the inner dial to realized frame by frame playback Only applies to some special versions To connect USB storage device USB mouse Remote control indication ligh
115. function Input remote storage server IP address Input Remote storage server port number pelle File length The file length you upload to the FTP When setup is larger than the actual file length system will upload the whole file When setup here is smaller than the actual file length system only uploads the set length and auto ignore the left section When interval value is 0 system uploads all corresponding files The password you need to log in the server Remote Path Remote storage file path Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Refresh Click this button to get device latest configuration information NTP The NTP interface is shown as in _ Figure 7 36 Here you can realize network time synchronization Please enable current function and then input server IP port number time zone and update interval Please note the SNTP supports TCP 142 transmission only and its port shall be 123 The update interval ranges from 1 to 65535 Default value is 10 minutes ll Control Panel AA A a 4 Query System Info W Enable VERSION HDD INFO Server F NTPServer Ef LOG ae 123 44 System Config 2 GENERAL eE GMT 08 00 ENCODE SCHEDULE Update Period i Minute Rose NETWORK EMAIL DDNS NAS 3 NTF ALARM CENTER ALARM DETECT PAMITILT ZOM DEFAULT BACKUP ADVANCED HOD MANAGEMENT ABWORMITY Alarm I O Config Record
116. gh system is encoding Lock normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection status are shown on the bottom left of display screen Color Hue brightness contrast saturation and gain setup for each channel Configuratio n Audio Audio inout 4 ch 200 2000mv 4 ch 200 2000mv 4 ch 200 2000mv p 10KQ BNC 10KQ BNC 10KQ BNC Privacy Support one privacy mask of user defined size in full screen mask Support max 4 zones MERE Channel information time information and privacy mask zone Information Audio 1 ch audio output 200 3000mv 5KO BNC Bidirectional 1 ch audio talk input 200 3000mv 10K 2 BNC 1 ch audio talk output 200 3000mv 5K Q BNC Hard Disk 4 built in SATA port Support 4 HDDs Hard Disk Audio PCM 28 8MByte h gees Occupation Video 56 900MByte h Manual recording motion detection recording schedule recording and Recording alarm recording Mode Priority Manual recording gt alarm recording gt motion detection recording gt schedule recording playback Recording 1 to 120 minutes single record duration Default setup is 60 minutes Length Record and Playback Repeat When hard disk is full system can overwrite previous video file Way Record Various search engines such as time type and channel search Playback Various fast play slow play speeds manual frame b
117. gure 4 40 click preset button and input preset number The interface is shown as in Figure 4 42 Now you can add this preset to one tour B PANTILTIZOOM X Function Preset Preset Tour Pattern Set Border Del Preset Patrol No 0 Figure 4 42 4 9 2 Activate Preset In Figure 4 41 please input preset number in the No blank and click preset button 4 9 3 Patrol setup Tour Setup In Figure 4 38 click patrol button The interface is shown as in Figure 4 43 Input preset number and add this preset to a patrol tour For each patrol tour you can input max 80 presets Function Preset Patrol Pattern Add Preset Border Del Preset Figure 4 43 79 4 9 4 Activate Patrol tour In Figure 4 40 input patrol tour number in the No blank and click patrol button 4 9 5 Pattern Setup In Figure 4 40 click pattern button and then click begin button The interface is shown as in Figure 4 44 Then you can go to Figure 4 37 X to modify zoom focus and iris Go back to Figure 4 44 and click end button You can memorize all these operations as pattern 1 lt 2 PAN TILT ZOOM xX Function Pattern 1 Preset Patrol Pattern Begin Border End Patrol No 0 Figure 4 44 4 9 6 Activate Pattern Function In Figure 4 39 input mode value in the No blank and click pattern button 4 9 7 Auto Scan Setup In _ Figure 4 38 click border button The interface is shown as in Figure 4
118. he WIFI interface is shown as below See Figure 5 26 WIFI SETTING WIFI Enable 0 SSID_ Signalintensity TP LINK_5D64F6 dl Current Hotspot mdvr y IP Address 10 7 0 22 AndroidAP Subnet Mask 255 255 0 0 TPLINK OM Gateway 10 7 0 1 Refresh Connect Disconnect Cancel Apply Figure 5 26 Refresh You can click it to search the hotspot list again It can automatically add the information such as the password if you have set it before Disconnect Here you can click it to turn off the connection Connect Here you can click it to connect to the hotspot System needs to turn off current connection and then connect to a new hotspot if there is connection of you selected one WIFI working status Here you can view current connection status 5 3 5 11 Alarm Centre This interface is reserved for you to develop 5 3 6 Alarm Please refer to chapter 4 6 Alarm Setup and Activation 97 5 3 7 Detect Please refer to chapter 4 5 Detect 5 3 8 Pan Tilt Zoom The pan tilt zoom setup includes the following items Please select channel first See Figure 5 27 Protocol Select corresponding PTZ protocol such as PELCOD Address input corresponding PTZ address Baud rate Select baud rate Data bit Select data bit Stop bit Select stop bit Parity There are three choices none odd even After completed all the setups please click save button system goes back to the previous menu For detailed setup please refe
119. htning arrester has many specifications and widely used in many devices such as telephone network analog communication digital communication cable TV and satellite antenna For all the input port especially those from the outdoor you need to install the signal lightning arrester e Antenna feed cable lightning arrester It is suitable for antenna system of the transmitter or the device system to receive the wireless signal It uses the serial connection too Please note when you select the lighting arrester please pay attention to the port type and the earthing reliability In some important environment you need to use special shielded cable Do not parallel connect the thunder proof ground cable with the ground cable of the lightning rod Please make sure they are far enough and grounded respectively 2 The earthing modes We all Know the earthing is the most complicated technology in the electromagnetism compatibility design since there is no systematic theory or module The earthing has many modes but the selection depends on the system structure and performance The following are some successfully experience from our past work One point ground In the following figure you can see there is a one point ground This connection provides common port to allow signal to be transmitted in many circuits If there is no common port the error signal transmission occurred In the one point ground mode each circuit is just grounded only and they ar
120. ideo Input NTSC PAL NTSC PAL NTSC PAL NTSC PAL NTSC PAL BNC BNC BNC BNC BNC Video monitor 1 OV p P 1 OV p P 1 OV p P 1 OV p P 1 OV p P 750 750 750 750 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output 1 ch VGA output Video Output 1 ch HDMI output 1 ch matrix output Support TV VGA HDMI video output at the same time Video 0 PAL 625 line 50f s NTSC 525 line 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s Record Speed per channel Video Partition windows O windows windows 116 25 16 25 36 optional windows windows Touring schedule auto control PAL NTSC Real time monitor D1 704x576 704x480 Playback channel 1 16 On D1 704 x 576 704 xXx 480 PAL NTSC CIF 352 X 288 352 X 240 QCIF 176X 144 176 x 120 Support dual streams Extra stream resolution CIF 352X 288 352 X 240 QCIF 176x144 176x120 Image Quality 6 level image quality Adjustable Support one privacy mask of user defined size in full screen Support max 4 zones Channel information time information and privacy mask zone Information TV Adjust Adjust TV output zone suitable to anamorphic video Channel Lock Cover secret channel with black screen though system is encoding normally Screen lock function to prevent unauthorized user seeing secret video Channel Channel name recording status screen lock status video loss status Information and motion detection sta
121. ind of substances or elements please return to the corresponding local authorities to process according to your local government statutes Note e This manual is for reference only Slight difference may be found in the user interface All the designs and software here are subject to change without prior written notice If there is any uncertainty or controversy please refer to the final explanation of us o Please visit our website or contact your local retailer for more information 187
122. is 37777 HTTP Port Default value is 554 UDP Port Default value is 37778 Max Connection Network user max amount The value ranges from 0 to 20 O means there is no user can access current device Email The email interface is shown as in _ Figure 7 33 Hetwork Mode Met Multiple Hetwork Card Ethernet Fort etno DHCP IF Address 10 Bb 3 JZ Mac Address Da GENERAL a ENCODE Gateway 10 6 O ig SCHEDULE po pe R5232 EE NETWORK TCP Port 37717 HITP Port feo UDF Port STTTS Maz Connection 20 Transfer Latency LAW Download ethO 20 11 04 07 19 12 Save Refresh 139 Configuration ll Control Panel Bf Query System Info Edf VERSION a HDD INFO Bf LOG F System Config a GENERAL ENCODE SCHEDULE RS232 La NETWORK Advance EMAIL DDNS NAS NTP ALARM CENTER UPNP Da ALARM 3 DETECT PAN TILT ZOOM DEFAULT BACKUP amp ADVANCED HDD MANAGEMENT ABNORMALITY Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCI 9 ADDTIONAL FUNCTION CARD OVERLAY Gan C EMAIL SMTP Server Port User Name Password Sender Subject Receiver 1 Receiver 2 Receiver 3 Send Interval Health ail Enable HealtyMail Interval Y Enable SSL Enable 0765500 gt Anonymous M Attachment guo_linglong dahuatech com DVR ALERT guo_linglong dahuatech com Minutes Refresh
123. ive thundering the International Electrotechnical Committee IEC standard on the energy absorbing step by step theory and magnitude classification in the protection zone you need to prepare multiple precaution levels You can use the lightning rod lightning strap or the lightning net to reduce the damage to the building personal injury or the property e The lightning protection device can be divided into three types Power lightning arrester There are 220V single phrase lightning arrester and 380V three phrase lightening arrester mainly in parallel connection sometimes use series connection You can parallel connect the power lightning arrester in the electric cable to reduce the short time voltage change and release the surge current From the BUS to the device there are usually three levels so that system can reduce the voltage and release the current step by step to remove the thunderstorm energy and guarantee the device safety You can select the replaceable module type the terminal connection type and portable socket according to your requirement e Signal lightning arrester This device is mainly used in the PC network communication system The connection type is serial connection Once you connected the signal lightning arrestor with the signal port it can cut the channel of the thunderstorm to the device and on the other hand it can discharge the current to the ground to guarantee the device proper 182 work The signal lig
124. lete Auto T our p Add Delete Delete Group Pattern p Start Record Stop Record Delete Assistant Camera rig Freset Titl Figure 7 13 7 2 3 Color Click color button in section 3 the interface is shown as Figure 7 14 Here you can select one channel and then adjust its brightness contrast hue and saturation Current channel border becomes green Or you can click default button to use system default setup Color More D G al A A _ _ Reset Figure 7 14 7 2 4 Picture Path and Record Path Click more button in Figure 7 14 you can see an interface is shown as in Figure 7 15 128 Color More FIC Path REC Path Reboot Record DAY oF At Figure 7 15 Click the record item you can see there are two options DAV ASF Click picture path button you can see an interface is shown as in Figure 7 16 Please click choose button to modify path Set Path Path C PictureDownload Choose Figure 7 16 Click record path button you can see an interface is shown as in _ Figure 7 17 Please click choose button to modify path 5et Path Path C Recor download Choose Set Figure 7 17 Click reboot button system pops up the following dialogue box See Figure 7 18 Please click OK to reboot Figure 7 18 lf there is local use logged in the system menu or the Web logged in user has no right to reboot the device system pops up a dialogue box to alert y
125. llow the steps listed below to enable the activation snapshot function After you enabled this function system can snapshot when the corresponding alarm occurred e In Encode interface click snapshot button to input snapshot mode size quality and frequency e In General interface please input upload interval e In Detect interface please enable snapshot function for specified channels Or in alarm interface please enable snapshot function for specified channels Please refer to the following figure for detailed information See Figure 4 17 66 Motion Detect gt f a elect Extra Straam1 v gt Cancel 4 5 2 3 Priority Set El l MW Alarm upload E EJ Select Cancel Cancel Local Alarm Select Default Save Cancel Figure 4 17 Please note the activation snapshot has the higher priority than schedule snapshot If you have enabled these two types at the same time system can activate the activation snapshot when alarm occurs and otherwise system just operates the schedule snapshot 4 5 3 Image FTP In Network interface you can set FTP server information Please enable FTP function and then click save button See Figure 4 18 Please boot up corresponding FTP server Please enable schedule snapshot Chapter 4 4 2 1 or activation snapshot Chapter 4 4 2 2 first now system can upload the image file to the FTP server Pp FTP Type Record FTP 7 Server IP os 2 i Port 21 User Name
126. m the format FAT or FAT32 Manufacturer Model C Capacity _ Cruzer Micro SanDisk cruzer mirco 2G SanDisk cruzer mirco 8G SanDisk Ti Cool 2G SanDisk Hongjiao 4G p NN Compatible SD Card List Please refer to the following sheet for compatible SD card brand SDHC2 Compatible Portable HDD List Please refer to the following sheet for compatible portable HDD brand Brand Model Capacity YDStar YDstar HDD box lomega RPHD CG Compatible USB DVD Burner List NOTE Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below And you can use the USB cable with the model recommended to set USB burner Manufacturer Mo _ ____ S DRX S70U TW200D Compatible SATA DVD Burner List NOTE Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below Manufacturer Me Compatible SATA HDD List NOTE Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below And SATA HDD should be used for the DVR with SATA port insecure sores ua ooo Judo Barracuda 10 ST3750640AS 750G SATA 175 Seagate Barracuda 10 ST3500630AS 500G SATA Seagate Seagate Seagate Seagate Seagate Seagate 206 Seagate Barracuda sTaeostiasa 80 satra 1606 3200 7506 5006 SATA SATA SATA Western Digital Cariar SE16 WD2500KS2 250G SATA Western Digital WD5000ABYS 500G ATA Western Digital Caviar Green series WD20EADS
127. manual frame by frame playback Mode and reverse play mode Various File Switch Ways Record and Can switch to previous or next file or any file in current play list Can switch to file on other channel of the same time If there is a file Support file continuous play when a file is end system auto plays the next file in the current channel 20 Multi channel There is 1 4 9 16 channel playback mode Playback It may vary due to different series Switch between self adaptive screen full screen when playback When in one window full screen playback mode you can select any Enlargement zone to activate partial enlargement function Backup HDD backup function Support peripheral USB backup device Flash disk portable disk Backup Mode USB burner and etc Support peripheral eSATA backup device Support network download and backup View monitor channel remotely DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance View alarm information such as external alarm motion detection and video loss via client Network Support network PTZ lens control control File download backup and playback Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Detection Vari
128. menu Warning System menu color language time display mode video format IP address user account will not maintain previous setup after default operation ae DEFAULT Cancel Figure 5 31 5 4 Search Please refer to chapter 4 3 Search 5 5 Advanced Double click advanced icon in the main window the interface is shown as below See Figure 5 32 There are total eight function keys HDD management alarm output abnormity manual record account auto maintenance TV adjust and video matrix 100 del ADVANCED p E error ABNORMALITY ALARM OUTPUT a e RECORD ACCOUNT AUTO MAINTAIN E ft TY ADJUST TEXT OVERLAY CONFIG BACKUP VIDEO MATRIX Figure 5 32 5 5 1 HDD Management Here is for you to view and implement hard disk management See Figure 5 33 You can see current HDD type status capacity and record time When HDD is working properly system is shown as O When HDD error occurred system is shown as X Alarm set Click alarm set button the interface is shown as below See Figure 5 34 This interface is just like the abnormity setup Please refer to chapter 5 5 2 for detailed information e HDD operation You can select HDD mode from the dropdown list such as read only or you can erase all data in the HDD Please note system needs to reboot to get all the modification activated HDD MANAGE Alarm Set HDD Setting Alarm Release Channels Setting HDD No 1
129. n mode is for 1 5U 2U series product Please follow the steps listed below Use twelve screws to fix the unit Please make sure the indoor temperature is below 35 C 95 Please make sure there is 15cm 6 inches space around the device to guarantee sound ventilation Please install from the bottom to the top lf there are more accessories connected in the rack please take precaution measures in case the rack power is overload 3 5 Connecting Power Supply Please check input voltage and device power button match or not We recommend you use UPS to guarantee steady operation DVR life span and other peripheral equipments operation such as cameras 3 6 Connecting Video Input and Output Devices 45 3 6 1 Connecting Video Input The video input interface is BNC The input video format includes PAL NTSC BNC 1 0Vp p 750 HD S series BNC 0 8VP P 750 The video signal should comply with your national standards The input video signal shall have high SNR low distortion low interference natural color and suitable lightness Guarantee the stability and reliability of the camera signal The camera shall be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc The camera and the DVR should have the same grounding to ensure the normal operation of the camera Guarantee stability and reliability of the transmission line Please use high quality sound shielded BNC Please
130. n shall work with special DDNS server and special Professional Surveillance Software PSS 5 3 5 7 UPNP The UPNP protocol is to establish a mapping relationship between the LAN and the WAN Please input the router IP address in the LAN in Figure 5 9 Double click the UPNP item in Figure 5 10 you can see the following interface See Figure 5 17 eo UPNP on off Turn on or off the UPNP function of the device eo Status When the UPNP is offline it shows as Unknown When the UPNP works it shows Success e Router LAN IP It is the router IP in the LAN WAN IP It is the router IP in the WAN e Port Mapping list The port mapping list here is the one to one relationship with the router s port mapping setting e Enable Switch It shows that the function of port mapping is enabled in this port o List lt gt Service name Defined by user lt gt Protocol Protocol type lt gt Internal port Port that has been mapped in the router 92 lt gt External port Port that has been mapped locally e Default UPNP default port setting is the HTTP TCP and UDP of the DVR e Add io the list Click it to add the mapping relationship Delete Click it to remove one mapping item Double click one item you can change the corresponding mapping information See Figure 5 18 Important When you are setting the router external port please use 1024 5000 port Do not use well known port 1 255 and the system port 256 102
131. n the FTP e Now you can set upload file length picture upload interval upload file channel time and type lt File length is upload file length When setup is larger than the actual file length system will upload the whole file When setup here is smaller than the actual file length system 95 only uploads the set length and auto ignore the left section When interval value is 0 system uploads all corresponding files lt gt Atthe same time you can set two periods three record files for different channels e Click the Test button you can see the corresponding dialogue box to see the FTP connection is OK or not See Figure 5 24 FTP Type Record FTP v Server IP Woo Wo WW sde Port 21 User Name Password Anonymous Remote Directory File Length 0 Channel 1 Weekday Fri Alarm Motion General Time Period 1 00 00 Time Period 2 00 00 R Cancel Figure 5 23 Message FTP Test Connect Failed Figure 5 24 5 3 5 10 WIFI Setting You can view the WIFI connection status in the Network Setting interface See Figure 5 25 You can view current connection status and IP address if there is a connection 96 Y NETWORK SETTING eer Trusted Sites 41 NTP time windows com 60 MULTICAST 239 255 42 42 FEROE DDNS No Available DDNS Setup UPNP Port Forwarding 3G SETTING EMAIL MailServer 25 R FTP Record FTP 0 0 0 0 ALARM SERVER Private 10 1 0 2 SNMP Default Cancel Figure 5 25 T
132. ncluded in the accessory bag 38 h 3 7 5 4 8 6 9 10 11 12 13 14 15 Figure 2 17 Please refer to the following sheet for detailed information Serial Number__ Name 1 Power button Click it to boot up or shut down the device 2 Address Click it to input device number so that you can control it normal speed playback normal playback Next record In playback mode playback the 5 next video previous video to realize normal playback button to pause playback In real time monitor mode click this button to enter video search menu Reverse pause Reverse playback pause mode click this button to realize normal playback In reverse playback click this button to pause playback 39 Cancel Go back to previous menu or cancel current operation close upper interface or control Record Start or stop record manually In record interface working with the direction buttons to select the record channel Click this button for at least 1 5 seconds system can go to the Manual Record interface Direction keys Switch current activated control go to left or right In playback mode it is to control the playback process bar Aux function such as switch the PTZ menu 12 Confirm menu key go to default button go to the menu 13 Multiple window switch Switch between multiple window and one window 14 Auxiliary key In 1 ch monitor mode pop up assistant function PTZ control and Video color Switch the
133. nformation 5 minute real time It is to playback the previous 5 minite record of playback current channel System may pop up a dialogue box if there is no 5 minute record in current channel Digital zoom It is to zoom in specified zone of current channel It supports zoom in function of multiple channel The selected area has an icon as and the free area is shown as an icon asia Real time backup It is to backup the video of current channel to function the USB device System can not backup the video of multiple channel at the same time Current selected backup channel has an icon as and the free channel is shown as an icon as Once the backup started you can see the free channel is shown as an icon as L Playback control The playback control has the following features e Support play pause and exit and drag function During the preview playback process you can not see the channel title and record status of current channel It will display the channel title and the record status once you exit the preview playback During the preview playback you can not switch the displayed channel or change current window display mode Please note the tour function has the higher priority than the preview playback System automatically exits the preview playback function and its corresponding interface when the tour function started You can not control the preview playback until the tour function ended 4 3 Manual Record
134. not exceed group right About reusable function this function allows multiple users use the same account to login After all the setups please click save button system goes back to the previous menu ACCOUNT 888888 Login Local 666666 Normal admin Normal default Default User Add User Modify User Add Group Modify Group Modify Password Figure 5 41 5 5 5 1 Modify Password Click password button the interface is shown as in Figure 5 42 Here you can modify account password Please select the account from the dropdown list input the old password and then input the new password twice Click the Save button to confirm current modification For the users of user account right it can modify password of other users 106 888888 Cancel Figure 5 42 5 5 5 2 Add Modify Group Click add group button the interface is shown as below See Figure 5 43 Here you can input group name and then input some memo information if necessary There are total 60 rights such as control panel shut down real time monitor playback record record file backup PTZ user account system information view alarm input output setup system setup log view clear log upgrade system control device and etc The modify group interface is similar to the Figure 5 43 2 Add Group v Control Panel v Shutdown the device v Monitor Y Monitor_CHO1 TO y 10 Monitor _CH03 Monitor CH04 Monitor CH05 Monitor CH06 Monit
135. nt ground For the radio frequency signal the capacitance is conducive and the circuit adopts multiple point ground When connecting devices of huge size the device physical dimension and connection cable is big comparing with the wave path of existed interference then there are possibility of interference when the current goes through the chassis and cable In this situation the interference circuit path usually lies in the system ground circuit When considering the earthing you need to think about two aspects The first is the system compatibility and the other is the external interference coupling into the earth circuit which results in system error For the external interference is not regular it is not easy to resolve 3 Thunder proof ground method in the monitor system e The monitor system shall have sound thunder proof earthing to guarantee personnel safety and device safety e The monitor system working ground resistance shall be less than 10 e The thunder proof ground shall adopt the special ground cable from the monitor control room to the ground object The ground cable adopts copper insulation cable or wire and its ground section shall be more than 20mm2 e The ground cable of the monitor system can not short circuit or mixed connected with the strong alternative current cable e For all the ground cables from the control room to the monitor system or ground cable of other monitor devices please use the copper resistan
136. nu GENERAL System Time 2011 04 15 11 52 38 Save Date Format YYYY MM DD Snapshot Date Separator v Time Format 24 HOUR Z Language ENGLISH is HDD Full Overwrite af Pack Duration 60 min Device No 3 Video Standard NTSC Auto Logout 10 Device ID DVR Startup Wizard Default Cancel Figure 5 3 00 00 Cancel 2008 06 01 00 00 2008 09 01 00 00 OK Cance Figure 5 5 84 5 3 2 Encode Encode setting includes the following items See Figure 5 6 Please note some series do not support extra stream Channel Select the channel you want Type Please select from the dropdown list There are three options regular motion detect alarm You can set the various encode parameters for different record types Compression System supports H 264 Resolution System supports various resolutions you can select from the dropdown list The main stream supports D1 HD1 BCIF CIF QCIF and the extra stream supports CIF QCIF Please note the option may vary due to different series Note a for HD SDI series the main code stream types are 1080P 720P D1 HD BCIF CIF QCIF Extra code stream resolution supports 1080P 720P D1 HD BCIF CIF QCIF b for 960H series the main code stream types are 960H D1 HD BCIF CIF QCIF Extra code stream resolution supports 960H D1 HD BCIF CIF QCIF Frame rate It ranges from 1f s to 25f s in NTSC mode and 1f s to 30f s in PAL mode Bit rate tyoe System
137. o edit the file ePlease play the file you want to edit and then click this button when you want to 11 Clip edit You can see the corresponding slide bar in the time bar of the corresponding channel You can adjust the slide bar or input the accurate time to set the file end time Click this button again and then save current contents in a new file de cod In any play mode the time bar will change once you modify the search type Click the R button system begins smart search System supports 396 22 18 PAL and 330 22 15 NTSC zones See Figure 4 13 00 00 00 On Pe O A O NA o tt O fl StartTime Type 00 00 00 R 00 10 00 R 00 20 00 R 00 30 00 R 00 40 00 R 00 50 00 R 01 00 00 R 01 10 00 R 01 20 00 R 01 30 00 R 01 40 00 R 01 50 00 R n E Smart search Synch All Record 4 Normal wv Alarm Y Motion STATE Quau Qahr Chiar Figure 4 13 13 Click no you can go to the smart search playback Click it again system stops smart search playback Please note When system is playing you can select a zone in the window to begin motion detect Click the motion detect button to begin play Current button is null once the motion detect play has begun The system will take the whole play zone as the motion detect region by default The motion detect play stopped once you switch the play file Operations such as set time bar click the play button or any file list operation will stop current motion detec
138. ogin protection to guarantee safety User friendly interface when login Provide the following options people can turn off DVR O E General Consumption 25W Exclude HDD Parameter Temperature 15 Working 10 90 Humidity 86kpa 106kpa 2U standard industrial case 440 W x460 D x89mm H Weight 6 5 7 5KG Exclude HDD Installation Desktop rack installation Mode 1 3 5 2U Series HD SDI series Main High performance industrial embedded micro controller System Processor Embedded LINUX System Multiplex operations Multiple channel record multiple channel playback Resources and network operation simultaneously User friendly graphical user interface Input Front panel USB mouse remote control Devices Method optional Function USB mouse to switch screen Compression Video Standard Compressio H 264 n Audio Compressio G 711A n Video Input 4 CH composite video input NTSC PAL BNC 1 0Vp p 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output Video 1 ch VGA output Output 1 ch HDMI output Support TV VGA HDMI video output at the same time Video monitor Video PAL 50f s NTSC 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s Record per channel Speed Video 1 4 windows Partition Monitor Support monitor tour functions such as alarm motion detection and Touring schedule auto control PAL 50f s NTSC 60f s Real time 10
139. on light in front panel will turn on L 4 s J i i 4 J 1 i Cancel Figure 4 9 59 e All channel manual record Please highlight ALL after Manual See Figure 4 10 When system is in manual recording all scheduled set up you have set in will be null Main menu gt Setting gt Schedule You can see indication light in front panel turns on system begins manual record now Cancel Figure 4 10 4 3 1 5 Stop all channel recording Please highlight ALL after Stop See Figure 4 11 System stops all channel recording no matter what mode you have set in the menu Main menu gt Setting gt Schedule 7 ppr OK Cancel Figure 4 11 4 4 Search amp Playback Click search button in the main menu search interface is shown as below See Figure 4 12 Usually there are three file types e R Regular recording file A External alarm recording file e M Motion detection recording file 60 Play from the RAN HDI y REC PIC lt Mar v 12011 gt Su Mo Tu We Th Fr Sa 1123 BLS 11 12 17 18 5 E Y 13 14 19 16 20 21 22 23 27 28 29 30 19 24 25 26 31 3 v 4 v 245 A a 00 00 00 de n 1 2 2 A 5 7 R q 1n 11 12 13 14 15 1A 17 18 19 an 21 22 23 24 a a a BS a o a aes a a a AA A a ps o Q2 gt qe 502 a a A AA gt A po o ee e ps LS eS ESSE o BS os BS LS O A e Bs e Sa SA SS ESS ESS ESS EE es ES
140. on to exit Anti dither System only memorizes one event during the anti dither period The value ranges from 3s to 600s Normal e There is 2 channel alarm output out e Corresponding to motion detection alarm output port multiple choices e Enable alarm activation function You need to select alarm output port so that system can activate corresponding alarm device when Period e Motion detection function becomes activated in the specified periods e There are six periods in one day Please draw a circle to enable corresponding period e Select date If you do not select current setup applies to today only You can select all week column to apply to the whole week e Click OK button system goes back to motion detection interface alarm occurs 148 Parameter Alarm System can delay the alarm output for specified time after alarm end latch The value ranges from 1s to 300s Show System pops up the alarm messages in the monitor interface message Buzzer Once you check the box here the buzzer beeps when an alarm occurred Alarm System can upload the alarm signal to the centre Including alarm upload centre Record System auto activates motion detection channel multiple choices to channel record once alarm occurs working with motion detection function Please note you need to go to Chapter 4 4 Schedule to set motion detection record period and go to chapter 4 2 Manual Record to set current period as auto record Record
141. onfiguration to other devices fA CONFIG BACKUP Device List Name Type Left space Total space sdb5 USB DISK 15 00 GB 15 00GB EXPORT IMPORT Figure 5 52 111 5 6 Information Here is for you to view system information There are total five items HDD hard disk information BPS data stream statistics Log and version and online user See Figure 5 53 E INFO X 8 VERSION ONLINE USERS Figure 5 53 5 6 1 HDD Information Here is to list hard disk type total space free space video start time and status See See Figure 5 54 0 means current HDD is normal X means there is error means there is no HDD If disk is damaged system shows as Please remove the broken hard disk before you add a new one Once there is a hard disk confliction please check hard disk time and system time is the same or not Please go to setting then general to modify system time At last reboot the system to solve this problem After system booted up if there is any confliction system goes to HDD information interface directly Please note system does not ask you to deal with it forcedly When HDD confliction occurs you can check system time and HDD time are identical or not If they are not identical please go to General Chapter 5 3 1 to adjust system time or go to HDD Management Chapter 5 5 1 to format HDD and then reboot the DVR ER HDD INFO ESATA 2 3 4 5 lie IR pe eal Space Free Space Stat
142. or CHO 1 2 3 4 5 6 8 9 O Cancel Figure 5 43 5 5 5 3 Add Modify User Click add user button the interface is shown as in Figure 5 44 Please input the user name password select the group it belongs to from the dropdown list Then you can check the corresponding rights for current user For convenient user management usually we recommend the general user right is lower than the admin account The modify user interface is similar to Figure 5 44 107 Add User admin v Control Panel Shutdown the device Monitor Monitor CH01 Monitor CH02 Monitor CHO03 Monitor CH04 Figure 5 44 5 5 6 Auto Maintain Here you can set auto reboot time and auto delete old files setup You can set to delete the files for the specified days See Figure 5 45 You can select proper setup from dropdown list After all the setups please click save button system goes back to the previous menu AUTO MAINTENANCE Every Tuesda 7 at 02 00 Custom Day s Ago Cancel Figure 5 45 5 5 7 TV Adjust Here is for you to adjust TV output setup See Figure 5 46 Please drag slide bar to adjust each item After all the setups please click OK button system goes back to the previous menu 108 Cancel Figure 5 46 5 5 8 Video Matrix Here you can set matrix output channel and its interval See Figure 5 47 lt can support the 1 4 9 16 window sport tour and you can specify the interval Note HD SDI s
143. ording Mode Priority Manual recording gt alarm recording gt motion detection recording gt schedule recording 1 to 120 minutes single record duration Default setup is 60 minutes Length Playback Repeat Way When hard disk is full system can overwrite previous video file Record Various search engines such as time type and channel search Playback Various fast play slow play speeds manual frame by frame playback Mode and reverse play mode Can switch to previous or next file or any file in current play list Can switch to file on other channel of the same time If there is a file Various File Switch Ways Support file continuous play when a file is end system auto plays the next file in the current channel Multi There is 1 4 channel playback mode channel Playback Switch between self adaptive screen full screen when playback Zoom Partial When in one window full screen playback mode you can select any zone Enlargemen to activate partial enlargement function t HDD backup Backup Support peripheral USB backup device Flash disk portable disk USB Moda burner and etc Support peripheral eSATA backup device Support network download and backup View monitor channel remotely deco DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance 17 Function video loss via client Multiple devices share information via corresponding
144. ositioning key See _ Figure 6 4 Please make sure your protocol supports this function and you need to use mouse to control Click this button system goes back to the single screen mode Drag the mouse in the screen to adjust section size Figure 6 4 Here is a sheet for you reference Name Function function Shortcut Function function Shortcut key key key key Zoom H Near p gt i Far gt gt Focus H Near 4 A Far gt Iris close ll lt a Open gt Il 6 2 Preset Patrol Pattern Border Function In Figure 6 2 click the set button The interface is shown as below Here you can set the following items Preset Patrol Pattern Border PAN TILT ZOOM gt Function Preset 1 Preset Patrol No Patrol Q Pattern Set Border Del Preset Figure 6 5 In Figure 6 2 click page switch button you can see an interface as in _ Figure 6 6 Here you can activate the following functions Preset Tour Patrol Pattern Auto scan Auto pan Flip Page Switch 117 Y PAN TILT ZOOM X No 0 Preset Pattern Tour AutoScan AutoPan Flip Reset Page Switch Figure 6 6 6 2 1 Preset Setup Note The following setups are usually operated in the Figure 6 2 _ Figure 6 5 and Figure 6 6 In Figure 6 2 use eight direction arrows to adjust camera to the proper position In Figure 6 5 click preset button and input preset number The interface is shown as in Figure 6 7 Add this preset to one patrol number _ P
145. ot the live cable at all For N Neutral cable Turn the digital multimeter to 750V AC use your one hand to hold the metal end and then the other hand insert the pen to the N port of the socket See the following figure If the multimeter shows 0 then you can see current N cable connection is standard If the value is more than 10 then you can see there Is inductive current and the neutral cable connection is not proper If the value is 120 then you can know misconnected the neutral cable to the live cable 186 Appendix H Toxic or Hazardous Materials or Elements Component NN Metal Case Plastic Parts Panel Fastener o o o Wire and Cable Ac Adapter Packing Material Accessories o e o o o o Note O Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T1 1363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environmental friendly use period EFUP period the toxic or hazardous substance or elements contained in products will not leak or mutate so that the use of these substances or elements will not result in any severe environmental pollution any bodily injury or damage to any assets The consumer is not authorized to process such k
146. ou 7 3 Configure 129 7 3 1 System Information 7 3 1 1 Version Information Here you can view device hardware feature and software version information See _ Figure 7 19 Configuration Control Panel BB Query System info Them oms O Oo if VERSION S N PASKADB0362 gt Video In Out 1671 T i Audio In Out 1671 Beir System Config Alarm In Out 16 6 E ad GENERAL Ethernet Port 1 D ENCODE sede i SCHEDULE Bios Version 2 606 0024 0 Build 2010 6 18 bie R5232 Ea NETWORK ADVANCED Ea HDD MANAGEMENT z ABNORMALITY Alarm 1 0 Config Record ACCOUNT SNAPSHOT z AUTO MAINTENANCE Matrix config H E ADDTIONAL FUNCTION Figure 7 19 7 3 1 2 HDD information Here you can view local storage status and network status including free capacity and total capacity See Figure 7 20 Configuration ll Control Panel AAA HDD INFO Y Query System Info SINO HDD Status Free Total Space Ef VERSION decida Total 446 15GB 465 74GB T INFO LocalHD 4 Working 446 15GB 465 74GB F System Config GENERAL ENCODE SCHEDULE NETWORK ALARM DETECT PAN TILT ZOOM DEFAULT BACKUP ADVANCED HDD MANAGEMENT ABNORMALITY Alarm IjO Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE Matrix config ADDTIONAL FUNCTION Figure 7 20 130 7 3 1 3 Log Here you can view system log See _ Figure 7 21 Configuration ll Control Panel BF Query System Info EY VERSION E HDD INFO Ef LOG F Syst
147. ou can see an interface is shown as in Figure 4 31 Here you can set your own setup for business day and non business day e Anti dither Here you can set anti dither time e Show message System can pop up a message to alarm you in the local host screen if you enabled this function e Alarm upload System can upload the alarm signal to the network including alarm centre if you enabled current function 12 Send email System can send out email to alert you when alarm occurs Record channel you can select proper channel to record alarm video Multiple choices At the same time you need to set alarm record in schedule interface Main Menu gt Setting gt Schedule and select schedule record in manual record interface Main Menu gt Advance gt Manual Record Latch Here is for you to set proper delay duration Value ranges from 10 to 300 seconds System automatically delays specified seconds in turning off alarm and activated output after external alarm cancelled Tour Here you can enable tour function when alarm occurs System supports one window tour Please go to chapter 5 3 9 Display for tour interval setup Buzzer Highlight the icon to enable this function The buzzer beeps when alarm occurs For snapshot operation please refer to chapter 4 4 2 Please highlight icon O to select the corresponding function After setting all the setups please click save button system goes back to the previous menu i Local Alarm
148. ous sensitivity levels Alarm can activate record or external alarm or screen message prompt Video Loss Alarm can activate external alarm or screen message prompt External Alarm Support record activation function or activate external alarm or screen message in specified period Manual Alarm Enable or disable alarm input channel Control Support analog alarm signal to specific alarm output channel 4 ch alarm input You 8 ch alarm input You 16 ch alarm input can set normal open can set normal open or You can set Alarm Input or normal close type to normal close type to normal open or select the alarm select the alarm type gt normal close type type to select the alarm type Alarm Output a relay output including one controllable DC 12V output Alarm Relay 30V DC 2A 125V AC 1A activation alarm USB Interface 3 USB 2 0 ports connection PTZ control port Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network Information Information Statistics Support various search engines such as time and type Network Function Motion Detection and Alarm econ Display version information channel amount alarm input and output amount system version and release date On line user Display current on line user User Multi lever user management various management modes Management Integrated management for local user serial port user and network
149. pt recommended Ol Download unsigned Actives controls not secure Disable recommended Enable mot secure O Prompt Ol Initialize and script Actives controls not marked as safe For si Disable recommended Enable not secure O Prompt Ol Run Activex controls and plug ins nn rrminictes tar anne 4 ilil Takes effect after vou restart Internet Explorer Reset custom settings Reset to medium high default v Figure 7 2 After installation the interface is shown as below See Figure 7 3 Please input your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login WEBservice Windows Internet Explorer Ln SES 7 E htp 110 10 3 16 ASI X Pir we k E WEBservice gt 0 6 Eprom Grow Done WE D Servitez v vs None MN Password MS e E Internet E 100 Figure 7 3 After you logged in you can see the main window See Figure 7 6 This main window can be divided into the following sections 122 e Section 1 there are five function buttons configuration chapter 7 3 search chapter 7 4 alarm chapter 7 5 about chapter 7 6 log out chapter 7 7 e Section 2 there are channel number and three function buttons start dialog and local play refresh Oo Section3 there are PTZ chapter 7
150. que MAC address lt is for you to access in the LAN It is read only P address Here you can use up down button A V or input the corresponding number to input IP address Then you can set the corresponding subnet mask the default gateway e Subnet prefix The input value ranges from O to 128 It is to mark a specified network MAC address Usually it includes an organization of multiple level e Default gateway Here you can input the default gateway Please note system needs to check the validity of all IPv6 addresses The IP address and the default gateway shall be in the same IP section That is to say the specified length of the subnet prefix shall have the same string e DHCP It is to auto search IP When enable DHCP function you can not modify IP Subnet mask Gateway These values are from DHCP function If you have not enabled DHCP function IP Subnet mask Gateway display as zero You need to disable DHCP function to view current IP information Besides when PPPoE is operating you can not modify IP Subnet mask Gateway e TCP port Default value is 37777 e UDP port Default value is 37778 eo HTTP port Default value is 80 e RTSP port Default value is 554 e Max connection system support maximal 20 users O means there is no connection limit o Preferred DNS server DNS server IP address eo Alternate DNS server DNS server alternate address e Transfer mode Here you can select the priority between fluency video qualitie
151. r to chapter 4 9 preset patrol pattern scan PAN TILT ZOOM PELCOD 1 115200 Paste Default Cancel Figure 5 27 5 3 9 Display Display setup interface is shown as below See Figure 5 28 Transparency Here is for you to adjust transparency The value ranges from 128 to 255 Channel name Here is for you to modify channel name System max support 25 digit The value may vary due to different series Please note all your modification here only applies to DVR local end You need to open web or client end to refresh channel name Time display You can select to display time or not when system is playback Channel display You can select to channel name or not when system is playback Resolution There are four options 1280 X 1024 default 1280 X 720 1024 x 768 800 x 600 Please note the system needs to reboot to activate current setup Enable tour Activate tour function Interval System supports 1 4 8 9 16 window tour Input proper interval value here The value ranges from 5 120 seconds In tour process you can use mouse or click Shift to turn on window switch function Stands for opening switch function stands for closing switch function Monitor tour type System support 1 8 window tour Alarm tour type System support 1 8 window tour 98 Please highlight icon O to select the corresponding function After completing all the setups please click save button system goes back to the previous menu Modify lution
152. revious multiple window mode In real time monitor mode pops up shortcut menu one window four window nine window and sixteen window Pan Tilt Zoom color setting search record alarm input alarm output main menu Among which Pan Tilt Zoom and color setting applies for current selected channel If you are in multiple window mode system automatically switches to the corresponding channel Right click mouse View 1 View 4 View 9 View 16 Pan Tilt Zoom Color Setting search Record Alarm Output Alarm Input Main Menu In numeral input box Increase or decrease numeral value Switch the items in the check box Page up or page down Move Select current control or move control mouse Drag mouse Select motion detection zone Select privacy mask zone Exit current menu without saving the modification 2 6 Virtual Keyboard amp Front Panel 2 6 1 Virtual Keyboard The system supports two input methods numeral input and English character small and capitalized input Move the cursor to the text column the text is shown as blue input button pops up on the right Click that button to switch between numeral input and English input capitalized and small Use gt or lt to shift between small character and capitalized character 2 6 2 Front Panel Move the cursor to the text column Click Fn key and use direction keys to select number you wanted Please click enter button to input 42 3 Installation
153. rocess bar for you reference When the system completes backup you can see a dialogue box prompting successful backup Selected Device sdb1 USB DISK Type All v Channel 1 File Format DAV y Start Time 2011 04 27 00 00 00 Remove Add End Time 2011 05 25 14 20 50 Onekey Backup CH Type Start Time End Time Size KB r 4 Page Up Page Down Fn Select Cancel backup device or file Space Required Space Remaining 0 00 KB 3 71 GB Start Figure 4 33 Click backup button system begins burning At the same time the backup button becomes stop button You can view the remaining time and process bar at the left bottom e File format Click the file format you can see there are two options DAV ASF e Picture backup Please set the corresponding time channel and then select the type as PIC from the dropdown list See Figure 4 34 Please click the Add button and then select the pictures Click the Start button you can copy the specified pictures to the selected portable devices Figure 4 34 e One key backup It includes three steps the search select all start the backup You can skip the above three steps and then copy all the searched files directly The file name format usually is SN_CH channel number time Y M D H M S In the file name the YDM format is the same as you set in general interface Main Menu gt Setting gt General File extension name is dav Tips During backup process
154. rresponding data bits Default value is 8 Stop bits select corresponding stop bits Default value is 1 Parity there are three options odd even none Default setup is none PAN TILT ZOOM PELCOD y 115200 Paste Default Cancel Figure 4 35 After completing all the setting please click save button In one window display mode right click mouse click Fn Button in the front panel or click Fn key in the remote control The interface is shown as in Figure 4 36 76 View 1 View 4 View 9 View 16 Color Setting search Record Alarm Output Alarm Input Main Menu Figure 4 36 Click Pan Tilt Zoom the interface is shown as below See Figure 4 37 Here you can set the following items o Step value ranges fro 1 to 8 eo Zoom e Focus O jris Please click icon kel and kd to adjust zoom focus and iris PANTILT ZOOM x 5 Zoom Focus Iris a Set Page Switch His lisis Figure 4 37 In Figure 4 37 please click direction arrows See Figure 4 38 to adjust PTZ position There are total 8 direction arrows Figure 4 38 4 8 3 3D Intelligent Positioning Key In the middle of the eight direction arrows there is a 3D intelligent positioning key SeeFigure 4 39 Please make sure your protocol supports this function and you need to use mouse to control TI Click this key system goes back to the single screen mode Drag the mouse in the screen to adjust section size
155. rt RS485 port can realize alarm input and PTZ control RS232 port can connect to keyboard to realize central control and can also connect to PC COM to upgrade system and realize maintenance and matrix control Standard Ethernet port can realize network access function Dual Ethernet ports support configuration modes such as multiple access Fault tolerance and load balancing e PTZ control Support PTZ decoder via RS485 Support various decode protocols to allow the PTZ to control the soeed dome e Intelligent operation Mouse operation function In the menu support copy and paste setup function UPnP lt is to establish the mapping relationship between the LAN and the WAN via the UPnP protocol Slight function differences may be found due to different series 1 3 Specifications 1 3 1 1U Series High performance industrial embedded micro controller Main System Processor Os Embedded LINUX LINUX gt aora operations Multiple channel record multiple channel playback tesources and network operation simultaneously User friendly graphical user interface Front panel USB mouse remote control Devices Method optional Function USB mouse to switch screen Compression Video Standard Compressio H 264 n Audio Compressio G 711A n 4 CH composite video 8 CH composite video 16 CH composite Video Input input NTSC PAL input NTSC PAL video input p BNC 1 0Vp p 750 BNC 1 0Vp p 750 NTSC PAL BNC
156. s e LAN download System can process the downloaded data first if you enable this function The download speed is 1 5X or 2 0X of the normal speed Important For the IP address of IPv6 version default gateway preferred DNS and alternate DNS the input value shall be 128 digit It shall not be left in blank After completing all the setups please click save button system goes back to the previous menu 87 E NETWORK IPv6 E Subnet Prefix fe80 5054 4cft fed6 16ec 64 HTTP Por RTSP Por 554 IP Version MAC Address IP Address Gateway TCP Port UDP Port Max Connection Preferred DNS ffff 3 8 8 8 Alternate DNS 1fff 8 8 4 4 O Transfer Mode E LAN Download Latency B NETWORK SETTING _ Default _ MET Default Save Cancel Figure 5 9 5 3 5 1 Network Setting Network setting interface is shown as in Figure 5 10 Please draw a circle to enable corresponding function and then double click current item to go to setup interface Dd IP FILTER NTP MULTICAST PPPOE DDNS UPNP Y 3G SETTING Y WIFI SETTING EMAIL FTP ALARM SERVER SNMP 9 3 9 2 IP Filter Trusted Sites 41 time windows com 60 239 255 42 42 No Available DDNS Setup Port Forwarding No connection MailServer 25 Record FIP 0 0 0 0 Private 10 1 0 2 Figure 5 10 IP filter interface is shown as in Figure 5 11 IPv4 and Figure 5 12 IPv6 You can add IP in the following list The list supports max 64
157. s external surge and internal surge e The external surge The external surge mainly comes from the thunder lightning Or it comes from the voltage change during the on off operation in the electric power cable e The internal surge The research finds 88 of the surge from the low voltage comes from the internal of the building such as the air conditioning elevator electric welding air compressor water pump power button duplicating machine and other device of inductive load The lightning surge is far above the load level the PC or the micro devices can support In most cases the surge can result in electric device chip damage PC error code accelerating the part aging data loss and etc Even when a small 20 horsepower inductive engine boots up or stops the surge can reach 3000V to 50000V which can adversely affect the electronic devices that use the same distribution box To protect the device you need to evaluate its environment the lighting affection degree objectively Because surge has close relationship with the voltage amplitude frequency network structure device voltage resistance protection level ground and etc The thunder proof work shall be a systematic project emphasizing the all round protection including building transmission cable device ground and etc There shall be comprehensive management and the measures shall be scientific reliable practical and economic Considering the high voltage during the induct
158. s below See Figure 5 1 There are total six icons search Information setting backup advanced and shutdown Move the cursor to highlight the icon then double click mouse to enter the sub menu 82 MAIN MENU gt lt gt D A SEARCH SETTING ME 10 16 Y q ADVANCED BACKUP SHUTDOWN Figure 5 1 5 3 Setting In main menu highlight setting icon and double click mouse System setting interface is shown as below See Figure 5 2 DE SETTING X A GENERAL ENCODE SCHEDULE RS232 NETWORK cuwepc ALARM DETECT PAN TILT ZOOM DISPLAY DEFAULT Figure 5 2 5 3 1 General General setting includes the following items See Figure 5 3 O System time Here is for you to set system time eo Date format There are three types YY YYY MM DD MM DD YYYYY or DD MM YYYY e Date separator There are three denotations to separate date dot beeline and solidus e DST Here you can set DST time and date Please enable DST function and then click set button You can see an interface is shown as in Figure 5 4 Here you can set start time and end time by setting corresponding week setup In Figure 5 4 enable date button you can see an interface is shown as in Figure 5 5 Here you can set start time and end time by setting corresponding date setup e Time format There are two types 24 hour mode or 12 hour mode e Language System supports various languages Chinese simplified Chinese Traditional English Italian
159. s the HDD Group number of current hard disk When you are setting the HDD Group please check the box of the hard disk and then choose the corresponding HDD Group number and save the settings In Figure 5 35 you can see the system has two working hard disks at the 6th and 7th position and the 6th position hard disk belongs to HDD Group 1 the 7th position hard disk belongs to HDD Group 2 102 A HDD Setting HDD Group HDD Group NO 1 Cancel Figure 5 35 In Figure 5 36 you can see the 6th and 7th position hard disks both belong to HDD Group 2 Important Once you change the HDD Group settings system will pack the records and snapshots and then reboot a HDD Setting HDD Group 0 0 J SO Om HB WH NO 10 12 HDD Group NO 2 Figure 5 36 Channels Setting Click the button named with Channels Settings at the top right corner of the Figure 5 33 system will pop up an interface shown as in Figure 5 37 When you are setting the configurations of the channels setting please select relevant channels first such as channel 1 to 16 and then select the HDD Group NO Please click the Save button to save current setup 103 The Figure 5 37 and Figure 5 38 show that channels 1 to 16 are associated to HDD Group NO 1 and channels 17 to 32 are associated to HDD Group NO 2 Therefore the records of channels 1 to 16 are stored into the hard disk s which belong to HDD Group NO 1 and the re
160. s to one group optional only Six frame ID groups verification can guarantee information validity and legal The start position length and data can be set according to your protocol and data packet There are total four fields Configuration ll Control Panel Query System Info Ef VERSION Sniffer Mode E HDD INFO Bf LOG F System Config GENERAL NONE y Set Com 1 2 s fsfs fs 7 8 s hof fr2 13 14 15 16 Protocol ENCODE SCHEDULE R5232 NETWORK ALARM DETECT Set Overlay Channel PAN TILT ZOOM DEFAULT BACKUP By ADVANCED P P gt Overlay Mode V Preview ENCODE HDD MANAGEMENT ABNORMALITY Alarm I O Config Record ACCOUNT SNAPSHOT AUTO MAINTENANCE MATRIX CONFIG MATRIX SPOT Overlay Pos LeftTop ADDTIONAL FUNCTION Auto Register Preferred DNS Refresh Figure 7 55 7 3 4 3 Auto Register Auto register interface is shown as below See Figure 7 56 Configuration ls Control Panel Bf Query System Info Bf VERSION Bf HDD INFO Ef Loc V Enable 4 System Config Da GENERAL ENCODE La SCHEDULE Da R5232 NETWORK ALARM Ea DETECT Ea PAN TILT ZOOM DEFAULT BACKUP amp ADVANCED La HDD MANAGEMENT ABNORMALITY Alarm I O Config 3 Record ACCOUNT La SNAPSHOT Ea AUTO MAINTENANCE MATRIX CONFIG MATRIX SPOT Device ID fo ADDTIONAL FUNCTION CARD OVERLAY Auto Register Preferred DNS Save Refresh Figure 7 56
161. save your current setup 7 3 2 1 General Setup Here you can set system time record length video format and etc See _ Figure 7 23 Configuration GENERAL 2011 4 15 13 50 23 a oie Sync PC iy MM OD Control Panel SP Query System Info Ef VERSION E HOD INFO Ef Los gt System Contig System Time Date Format DST Set SRE ENCODE SCHEDULE R523 NETWORK Date Separator Time Format Language HOD Full 24 H0UR ENGLISH od Overwrite ALARM DETECT PAN TILT 200M DEFAULT BACKUP ADVANCED HDD MANAGEMENT ABNORMALITY Alarm I O Config Record ACCOUNT SMAPSHOT AUTO MAINTENANCE ADOTIORAL FUNCTION CARD OVERLAY Auto Register Preferred DNS Minute KA DWR Fack Duration 60 Device No Video Standard Device Name Save Refresh Figure 7 23 C Week day Hour Mir o zie Cancel Dap 009 E 2 2009 J 2 Figure 7 24 132 C Day Month Week Week day Hour Min s xt Ae 4 fo Io ja xt Awa 1 fo Jo Figure 7 25 Please refer to the following sheet for detailed information Parameter Function System Here is for you to modify system time Please click Save button after Time your completed modification Sync PC You can click this button to save the system time as your PC current time Data Here you can select data format from the dropdown list Format Data Please select separa
162. security reason please modify password after you first login Within 30 minutes three times login failure will result in system alarm and five times login failure will result in account lock 55 833388 Figure 4 2 4 1 2 Main Menu After you logged in the system main menu is shown as below See Figure 4 3 There are total six icons search information setting backup advanced and shutdown You can move the cursor to highlight the icon and then double click mouse to enter the sub menu MAIN MENU X SETTING os ADVANCED BACKUP SHUTDOWN Figure 4 3 4 1 3 Logout There are two ways for you to log out One is from menu option In the main menu click shutdown button you can see an interface is shown as below See Figure 4 4 SHUTDOWN Logout menu user Cancel Figure 4 4 There are several options for you See Figure 4 5 Restar application Figure 4 5 56 The other ways is to press power button on the front panel for at least 3 seconds system will stop all operations Then you can click the power button in the rear panel to turn off the DVR 4 1 4 Auto Resume after Power Failure The system can automatically backup video and resume previous working status after power failure 4 1 5 Replace Button Battery Please make sure to use the same battery model if possible We recommend replace battery regularly such as one year to guarantee system time accuracy Note Before replacement
163. select suitable BNC model according to the transmission distance If the distance is too long you should use twisted pair cable and you can add video compensation devices or use optical fiber to ensure video quality You should keep the video signal away from the strong electromagnetic interference especially the high tension current Keep connection lugs in well contact The signal line and shielded wire should be fixed firmly and in well connection Avoid dry joint lap welding and oxidation 3 6 2 Connecting Video Output Video output includes a BNC PAL NTSC1 0Vp p 750 output a VGA output and HDMI output System supports BNC VGA and HDMI output at the same time When you are using pc type monitor to replace the monitor please pay attention to the following points e To defer aging do not allow the pc monitor to run for a long time e Regular demagnetization will keep device maintain proper status eo Keep it away from strong electromagnetic interference devices Using TV as video output device is not a reliable substitution method You also need to reduce the working hour and control the interference from power supply and other devices The low quality TV may result in device damage 3 7 Connecting Audio Input amp Output Bidirectional Audio 3 1 Audio Input These series products audio input port adopt BNC port Due to high impedance of audio input please use active sound pick up Audio transmission is similar to vid
164. software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Motion Detection Various sensitivity levels Detection and Alarm can activate record or external alarm or screen message prompt Alarm Video Loss Alarm can activate external alarm or screen message prompt External Support record activation function or activate external alarm or screen Alarm message in specified period Manual Enable or disable alarm input channel Alarm Support analog alarm signal to specific alarm output channel Control type to select the alarm type 6 channel relay output including one controllable DC 12V output port Output Alarm Relay 30V DC 2A 125V AC 1A activation alarm USB 3 USB 2 0 ports Interface Interface Network RJ45 10M 100M 1000M self adaptable Ethernet port connection PTZ control port iad Support various PTZ control protocols 4 ch alarm input You 8 ch alarm input You 16 ch alarm input can set normal open or can set normal open or You can set Alarm Input normal close type to normal close type to normal open or select the alarm type select the alarm type normal close RS232 Ordinary COM Debug keyboard connection and transparent serial port COM input and output via network System Hard Disk Display HDD current status Information Information Data Data stream
165. ss bar for your reference Select local record to play 163 Earliest Select a channel first and then click the earliest record record button you can view the earliest record of the current channel in the HDD Multiple System supports playback one file in several monitor channel chamnels playback During the playback process you can see there are control buttons such as play pause stop slow play and fast play in the play process bar You can view current playback file channel name time and data statistics In the search result interface you can select one or more files to download to your local PC The playback control bar is shown as below See Figure 7 63 1 Play 2 Pause 3 Stop 4 Slow play 5 Fast play Playback device IP address and channel number r hy 2 A Oa ey LE q E we y a7 VAT 7 A Playback control bar oo iL Gs Ge ES OES ee 5 B8 gt Figure 7 63 7 5 Alarm Click alarm function you can see an interface is shown as in Figure 7 64 Here you can set device alarm type and alarm sound setup 164 Event Type Operation E sternal Alarm can not open video Video Loss M Encoder Alarm Listen Alar Video Pop up Prompt Motion Detect External Alarm Disk Full Disk Error Sound Pop up Video Mask Sound Path gt Alarm Sound Time DevicelD Event Type Alarm Port Channel Figure 7 64 Please refer to the following sheet for detailed
166. statistics for each channel in wave mode Stream Statistics Log Backup to 1024 log files statistics Support various search engines such as time and type Versi Display version information channel amount alarm input and output ersion amount system version and release date Display current on line user User Multi lever user management various management modes Management User Integrated management for local user serial port user and network user Manageme Configurable user power nt Support user group and its corresponding rights modification No limit to the user or group amount ala Password modification Administrator can modify other user s password Authenticati ae Account lock strategy Five times login failure in thirty minutes may result in account lock Upgrade Web browser client end and update tool Password login protection to guarantee safety User friendly interface when login Provide the following options Logout shutdown restart Login Logout and Shutdown 18 Right authentication when shut down to make sure only those proper people can turn off DVR AC90 264V 50 2 Hz Max 220W Power General Consumptio Snax i PHOT 50W Exclude HDD Working 060 2D5 Temperatur e Working 10 90 Humidity Air 86kpa 106kpa Pressure 2U standard industrial case 440 W x460 D x89mm H Weight 7 0 8 0KG Exclude HDD Installation Desktop rack installation Mode 1 3 5 2U Series
167. t Shuttle outer ring Jog inner dial USB port Remote control indication light gt O Status indication light Status lf there is Fn indication light current status indication light is null Power indication pwr Power indication light 1 32 It becomes on when system is recording It is to receive the signal from the remote control light Record light IR Receiver 2 2 Rear Panel 2 2 1 1U series The 4 8 channel series DVR rear panel is shown as below See Figure 2 5 Figure 2 5 The 16 channel series DVR rear panel is shown as below See Figure 2 6 4 6 8 11 15 00000000 00000000 Figure 2 6 Please refer to the following sheet for detailed information Video input Audio input Video spot output Video CVBS output Bidirectional talk input 2 2 2 1 5U series The rear panel is shown as in Figure 2 7 29 3 6 T E 9 11 Cute i 2s sts ts ee Goneeneden su ok ao eh Figure 2 7 Please refer to the following sheet for detailed information 6 Videoinput S O 8 Bidirectional talk input port 9 Bidirectional talk output port Video VGA output HDMI port RS232 port eSATA port USB port Network port 2 2 3 Simple 1 5U This series DVR rear panel is shown as below See Figure 2 8 Figure 2 8 Please refer to the following sheet for detailed information Video input Video spot output Video CVBS output Audio input Bidirectional
168. t channel Multi There is 1 4 9 16 channel playback mode channel It may vary due to different series Playback Switch between self adaptive screen full screen when playback Zoom Partial When in one window full screen playback mode you can select any zone Enlargemen to activate partial enlargement function t Backup HDD backup function Backu Support peripheral USB backup device Flash disk portable disk USB eae p burner and etc Support peripheral eSATA backup device Support network download and backup View monitor channel remotely DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance View alarm information such as external alarm motion detection and video loss via client Support network PTZ lens control File download backup and playback Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Motion Detection Various sensitivity levels Network Function Network control Detection and Alarm can activate record or external alarm or screen message prompt Alarm Video Loss Alarm can activate external alarm or screen message prompt Alarm message in specified period Manual Enable or disable alarm input channel Alarm Support an
169. t ness hue saturation and gain The value ranges from 0 to 100 Default value is 50 See Figure 7 27 Please note some series devices do not support OSD transparent setup function Color Setting Cover area e Here you can privacy mask the specified video in the monitor video privacy mask e One channel max supports 4 privacy mask zones e The privacy mask includes two options Never monitor Never It means do not enable privacy mask function Monitor the privacy mask zone can not be viewed in monitor mode Time Title e You can enable this function so that system overlays time information in video window e OSD transparent value ranges from 0 to 255 O means complete transparent Please note OSD transparent setup is form special series only e You can use the mouse to drag the time tile position Channel Title e You can enable this function so that system overlays channel information in video window e OSD transparent value ranges from 0 to 255 0 means complete transparent e You can use the mouse to drag the channel tile position 135 Parameter Function Copy It is a shortcut menu button You can copy current channel setup to one or more channels The interface is shown as in _ Figure 7 28 Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Refresh Click this button to get device latest configuration information
170. t play Important System does not support motion detect zone setup during the full screen mode Other Functions Other channel When playing the file click the number button system can 14 synchronization switch to switch to the same period of the corresponding channel to play when playback play e When the system is in full screen playback mode left click i AOE the mouse in the screen Drag your mouse in the screen to 63 select a section and then left click mouse to realize digital zoom You can right click mouse to exit Note All the operations here such as playback speed channel time and progress have relationship with hardware version Some series DVRs do not support some functions or playback speeds 4 5 Schedule After system booted up it is in default 24 hour regular mode You can set record type and time in schedule interface 4 4 1 Schedule Menu In the main menu from setting to schedule you can go to schedule menu See Figure 4 14 e Channel Please select the channel number first You can select all if you want to set for the whole channels Week day There are eight options ranges from Saturday to Sunday and all e Pre record System can pre record the video before the event occurs into the file The value ranges from 1 to 30 seconds depending on the bit stream e Redundancy System supports redundancy backup function It allows you backup recorded file in two disks You can highlight Redundanc
171. talk input Audio output Network port USB port 30 9 HDMiport S On off button GND port 2 2 4 2U series This series DVR rear panel is shown as below See Figure 1 2 4 6 d 1112 13 14 15 161718 19 20 Figure 2 9 Please refer to the following sheet for detailed information ERIN Bidirectional talk input port Bidirectional talk output port 15 Video VGA output 16 HDMI port Video CVBS output RS232 port Video matrix output eSATA port 19 USBpot S USB port Network port 2 2 5 2U series HD SDI series 31 ORES a eon 1 2 4 5 6 12 13 14 15 16 17 Figure 2 10 Please refer to the following sheet for detailed information GND port Power input port Power button Fan 6 Loopvideo output S 8 Bidirectional talk input pot 9 Bidirectional talk output port Video output ll 1 Audio output Video output Audio output S 1 Alarm input Alarm output RS485 port HDMI port 0 1 2 Network port Video VGA output HDMI port USB port eSATA port Video CVBS output RS232 port 2 2 5 2U series 960H series The rear panel is shown as in Figure 2 11 1 2 4 6 5 11 12 13 14 20 16 17 18 19 15 Figure 2 11 Please refer to the following sheet for detailed information 32 When connect the Ethernet port please use crossover cable to connect the PC and use the 6 1 4channelaudioinput 7 Loopvideooutput SSS 8 V 3 10 7 Video CVBS output 10 Matrix video output
172. tatus e 2 Change show mode resize or switch to full screen mode e 3 Local record When you click local record button the system begins recording and this button becomes highlighted You can go to system folder RecordDownload to view the recorded file e 4 Capture picture You can snapshoot important video All images are memorized in system client folder download picture default e 5 Audio Turn on or off audio lt has no relationship with system audio setup eo 6 Close video Please refer to Figure 7 9 for main stream and extra stream switch information 124 EH cam 1 Wain Stream Extra Stream ed CAM 2 ed CAM 3 ed CAM 4 ed CAMS Ed CAN 6 es CAM 7 le CAM g ed CAM o CAN 10 es CAM 11 ed CAM 12 ll CAM 13 ed CAM 14 e8 CAM 15 EK Cam 16 Open All StatDialog Y Local Play Refresh Figure 7 9 Open All You can click it to open all channels Refresh You can use button to refresh camera list Start Dialogue You can click this button to enable audio talk Click W to select bidirectional talk mode There are two options DEFAULT G711a Please note the audio input port from the device to the client end is using the first channel audio input port During the bidirectional talk process system will not encode the audio data from the 1 channel Local Play The Web can playback the saved Extension name is dav files in the PC end Click local play button system pops up the following interface
173. the mouse or click the ENTER button to playback eYou can input the period in the following interface to begin accurate search File type R regular record A external alarm record M Motion detect record 00 00 00 Qs The card number search interface is shown as below Card 3 switch button number search Play Pause There are three ways for you to begin playback e The play button e Double click the valid period of the time bar e Double click the item in the file list In slow play mode click it to switch between play pause Backward play In normal play mode left click the button the file begins backward play Click it again to pause current play In backward play mode click gt 11 to restore normal play In playback mode click it to play the next or the previous section You can click continuously when you are watching the files from the same channel In normal play mode when you pause current play you can click and gt to begin frame by frame playback Playback In frame by frame playback mode click IIl to restore normal playback control Slow play pane In playback mode click it to realize various slow play modes such as slow play 1 slow play 2 and etc Fast forward In playback mode click to realize various fast play modes such as fast play 1 fast play 2 and etc Note The actual play speed has relationship with the software version The volume of the playba
174. the un installation might result in error 7 2 Login Open IE and input DVR address in the address column For example if your DVR IP is 10 10 3 16 then please input http 10 10 3 16 in IE address column See _ Figure 7 1 Blank Page Windows Internet Explorer WI E about blank l Input your IP de a Blank Page 75 deb Page Tools gt FM address here Internet E 100 Figure 7 1 System pops up warning information to ask you whether install webrec cab control or not Please click yes button If you can t download the ActiveX file please modify your settings as follows See _ Figure 7 2 121 Internet Options General Security Privacy Content Connections Programs Advanced Select a zone to view or change security settings y a Y 5 Internet Local intranet Trusted sites lt Internet This zone is For Internet websites except those listed in trusted and restricted zones Security level For this zone Allowed levels For this zone Medium to High Medium high Appropriate For most websites Prompts before downloading potentially unsafe content Unsigned Actives controls will not be downloaded Custom level Reset all zones to default level Default level mn Security Settings Internet Zone Settings Disable Enable a Download signed Activex controls not secure Disable 2 Enable not secure Prom
175. tor such as or Separator Time There are two options 24 H and 12 H Format DST Here you can set day night save time begin time and end time See Figure 7 24 and Figure 7 25 Language You can select the language from the dropdown list Device needs to reboot to get the modification activated HDD Full There are two options stop recording or overwrite the previous files when HDD is full When current working HDD is overwriting or it is full now system stops record If current working HDD is full now system goes to overwrite the previous file Pack Here you can select file size The value ranges from 1 to 120 Default Duration setup is 60 minutes Device No When you are using one remote control not included in the accessory bag to manage multiple devices you can give a serial numbers to the device Video There are two options PAL NTSC Standard Please note for the Web user this information is for reference only You can not modify Please input the corresponding device name here 7 3 2 2 Encode Encode interface is shown as in Figure 7 26 133 Configuration Control Panel Bf Query System Info Ef VERSION E HDD INFO Ef LOG F System Config GENERAL 2 ENCODE 3 SCHEDULE RS232 La NETWORK ALARM DETECT Ea PAN TILT ZOOM DEFAULT BACKUP ADVANCED HDD MANAGEMENT ABNORMALITY Alarm I O Config Record Ca ACCOUNT SNAPSHOT AUTO MAINTENANCE Matrix config ADDTIONAL FUNCTION Channel
176. tus are shown on the bottom left of display screen Color Hue brightness contrast saturation and gain setup for each channel Configuration Audio Bidirectional 1 ch audio talk input 200 3000mv 10KQ BNC Audo 1 ch audio talk output 200 3000mv 5K 2 BNC Hard Disk 8 built in SATA port Support 8 HDDs 13 Hard Disk Audio PCM 28 8MByte h Hard disk Occupation Video 56 900MByte h Manual recording motion detection recording schedule recording and Recording alarm recording Mode Priority Manual recording gt alarm recording gt motion detection Record and recording gt schedule recording playback 1 to 120 minutes single record duration Default setup is 60 minutes Length Playback Repeat Way When hard disk is full system can overwrite previous video file Record Search Various search engines such as time type and channel Playback Various fast play slow play speeds manual frame by frame playback Mode and reverse play mode Various File Switch Ways Can switch to previous or next file or any file in current play list Can switch to file on other channel of the same time If there is a file Support file continuous play when a file is end system auto plays the next file in the current channel Multi channel There is 1 4 9 16 channel playback mode Playback It may vary due to different series Switch between self adaptive screen full screen when playback Partial When in one window full screen play
177. uded The front panel of general series is shown as in Figure 2 3 Digital Video Recorder The Front panel of HD SDI series and 960H series is shown as follows See Figure 2 4 26 Figure 2 4 Please refer to the following sheet for front panel button information Name Icon Function Power button Power button press this button for three seconds to boot up or shut down DVR Input Arabic number Number button Switch channel Input number En If you want to input a number more than 10 please click this more than 10 button and then input In textbox click this button to switch between numeral English Small Capitalized donation and etc Enable or disable tour Activate current control modify setup and then move up and down sl A i id Down ncrease decrease numeral Assistant function such as PTZ menu Shift Left Shift current activated control and then move left and right e Right When playback click these buttons to control playback bar y A Go to previous menu or cancel current operation ESC When playback click it to restore real time monitor mode REC n Confirm current operation Enter ENTER Go to default button Go to menu Record Manually stop start recording working with direction keys or numeral keys to select the recording channel Slow play Multiple slow play speeds or normal playback for 1 5seconds to delete the previous character be
178. ur e Working 10 90 Humidity Air 86kpa 106kpa Pressure 1U standard industrial case 375 W x280 D x50mm H Weight 1 5 2 5KG Exclude HDD Installation Desktop installation Mode 1 3 2 1 5U Series Main High performance industrial embedded micro controller System Processor Resources and network operation simultaneously Devices Method optional Function USB mouse to switch screen Video Compressio H 264 n Audio Compressio G 711A n Compression Standard 4 CH composite video 8 CH composite video 16 CH composite input NTSC PAL input NTSC PAL video input BNC 1 0Vp p 750 BNC 1 0Vp p 750 NTSC PAL BNC 1 0Vp p 750 1 ch PAL NTSC BNC 1 0VP P 750 composite video signal output Video Input Video monitor 1 ch VGA output ae if 1 ch HDMI output i 1 ch matrix output Support TV VGA HDMI video output at the same time Video Standard PAL 625 line 50f s NTSC 525 line 60f s Real time Mode PAL 1f s to 25f s per channel and NTSC 1f s to 30f s EGO per channel Speed Partition Touring schedule auto control PAL NTSC Real time monitor D1 704x576 704x480 Resolution PALINTSC Payback 1 16 ch D1 704x576 704x480 CIF 352x288 352x240 QCIF 176x144 176x120 QCIF 176x144 176x120 6 level image quality Adjustable Quality Adjust TV output zone suitable to anamorphic video Channel Cover secret channel with black screen thou
179. us Bad block i All 465 74 GB 455 89 GB 1 Read Write 465 74 GB 455 89 GB Normal Normal 4 Page Up Page Down F View recording times Figure 5 54 112 Tips Please click Fn button or left click mouse to view HDD record time and HDD type and time 5 6 2 BPS Here is for you to view current video data stream KB s and occupied hard disk storage MB h See Figure 5 55 Figure 5 55 5 6 3 Log Here is for you to view system log file System lists the following information See Figure 5 56 Log types include system operation configuration operation data management alarm event record operation log clear and etc Pleased select start time and end time then click search button You can view the log files System max displays 100 logs in one page It can max save 1024 log files Please page up down button to view if there are more than ten files System also supports the backup function you can click the backup button to save the log files in the USB devices LOG Type All v Start Time 2011 03 09 00 00 00 End Time 2011 03 10 00 00 00 Details Search Event 2011 03 09 16 03 12 Playback file 2011 03 09 16 03 12 Page Up 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 2011 03 09 16 03 12 4Page Up Page Down Page Down
180. ut number 0 e Go to previous menu or cancel current operation ESC ESC When playback click it to restore real time monitor mode One window monitor mode click this button to display Assistant assistant function PTZ control and image color 23 Shift In textbox click this button to switch between numeral English Small Capitalized donation and etc Manually stop start recording working with direction keys or numeral keys to select the recording channel Remote control indication light Remote control Indication light Status If there is Fn indication light current status indication light is indication Status lI light de Power indication Power Power indication light light System IS ial or not It becomes on when system is a It is to receive the signal from the remote control CD ROM Pop up or insert the CD Note the front panel of simple 1 5U also adopts the above panel model Backspace function in numeral control or text control press it for 1 5 seconds to delete the previous character before the cursor In motion detection setup working with Fn and direction keys to realize setup In text mode click it to switch between numeral English character small capitalized and etc In HDD management interface you can click it to switch HDD record information and other information Menu prompt Realize other special functions 2 1 3 2U series HD SDI series 960H incl
181. utput Please highlight icon O to select the corresponding alarm output After all the setups please click OK button system goes back to the previous menu See Figure 5 40 Cancel Figure 5 40 5 5 4 Manual Record Please refer to chapter 4 2 2 manual record 5 5 5 Account Here is for you to implement account management See Figure 5 41 Here you can Add new user Modify user Add group Modify group Modify password For account management please note 105 For the user account name and the user group the string max length is 6 byte The backspace in front of or at the back of the string is invalid There can be backspace in the middle The string includes the valid character letter number underline subtraction sign and dot System account adopts two level management group and user No limit to group or user amount For group or user management there are two levels admin and user The user name and group name can consist of eight bytes One name can only be used once There are four default users admin 888888 666666 and hidden user default Except user 6666 other users have administrator right Hidden user default is for system interior use only and can not be deleted When there is no login user hidden user default automatically login You can set some rights such as monitor for this user so that you can view some channel view without login One user should belong to one group User right can
182. with device power end Alarm device connection terminal Alarm device connection terminal O ALARM GND Figure 3 5 51 3 8 3 Alarm Output Port e Provide power to peripheral alarm device e To avoid overloading please read the following relay parameters sheet carefully e RS485 A B cable is for the A B cable of the PTZ decoder Relay Specification Model JRC 27F touch iA Insulation Between touches with same 1000VAC 1minute polarity Between touches with different 1000VAC 1minute polarity Between touch and winding 1000VAC 1minute Between touches with same Surge voltage polarity 1500V 10x160us Length of open 3ms max time Length of close 9MS Max time Electrical 200x103 times 0 5Hz 3 9 RS232 You can connect the DVR with POS or Keyboard through RS232 With POS system the DVR can communicate through RS232 and network For the POS system the DVR can integrate the text content and even search the record through the info The series DVR also support NKB operation You can operate the DVR from the keyboard controls instead of using the control pad on the front panel of the unit To connect a NKB keyboard to the DVR 1 Assemble the KBD keyboard according to the instructions in its accompanying installation manual 2 Connect the KBD keyboard into one of the RS232 ports on the DVR or through network 3 10 RS485 When the DVR receives a camera control command it transmits that command up the co
183. y button to activate this function Please note before enable this function please set at least one HDD as redundant Main menu gt Advanced gt HDD Management Please refer to chapter 4 4 1 2 for detailed information e Snapshot You can enable this function to snapshoot image when alarm occurs O Record types There are four types regular motion detection MD Alarm MD 4 alarm Please highlight icon O to select the corresponding function After completing all the setups please click save button system goes back to the previous menu At the bottom of the menu there are color bars for your reference Green color stands for regular recording yellow color stands for motion detection and red color stands for alarm recording The white means the MD and alarm record is valid Once you have set to record when the MD and alarm occurs system will not record neither motion detect occurs nor the alarm occurs jp SCHEDULE Channe PreRecord 4 sec Redundancy Snapshot Week Day Record Type Regular MD Alarm MO amp Alarm Period 1 24 00 a amp Period2 0 24 00 Period3 00 00 24 00 Period 4 24 00 Period 5 i 24 00 Period 6 DO 00 24 00 Alarm Default Save Cancel Figure 4 14 64 4 5 1 1 Quick Setup This function allows you to copy one channel setup to another After setting in channel 1 you can click paste button and turn to channel 2 and then click copy button You can finish setting for one channel an
184. y frame playback Mode and reverse play mode Can switch to previous or next file or any file in current play list Can switch to file on other channel of the same time If there is a file Various File Switch Ways Support file continuous play when a file is end system auto plays the next file in the current channel Multi There is 1 4 9 16 channel playback mode channel It may vary due to different series Playback Switch between self adaptive screen full screen when playback Zoom Partial When in one window full screen playback mode you can select any zone Enlargemen to activate partial enlargement function t Backup HDD backup function Backu Support peripheral USB backup device Flash disk portable disk USB Mode p burner and etc Support peripheral eSATA backup device Support network download and backup View monitor channel remotely i DVR configuration through client end and web browser Upgrade via client or browser to realize remote maintenance Function video loss via client Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex transparent COM Network alarm input and output Bidirectional audio Motion Zone setup support 396 PAL 22x18 NTSC 22x15 detection zones Motion Detection Various sensitivity levels Detection and Alarm can activate record or external alarm or screen message prompt Alarm Video Loss Alarm can a
Download Pdf Manuals
Related Search
Related Contents
Operator`s Manual User's Manual Dawn Care Hoist Master Node Service Manual Grizzly G0634Z Planer User Manual Mutitool Manual_GER+FRZ PREVIEW Chief FCA610B Samsung ML-4510ND manual do usuário Copyright © All rights reserved.
Failed to retrieve file