Home

Manual - Hearth & Home Technologies

image

Contents

1. Existings Combustible Framing Ceiling support Metal studs support 7 16 Durock or equivalent ceiling Fig 23 Reflected ceiling plan E Nid iF 7 16 Durock or equivalent spaced 1 off wood studs on noncombustible spacers package extends 2 below Du rock or equiva lent ceiling _ 1 air gap top bottom on both sides and back wall NOTE From 62 to 65 must be covered by a noncombusti ble material Fig 26 Front section 65 minimum clearance to combustibles on front face Combustible facing may overlap metal studs by only Fig 24 Floor plan Sheetrock on front face butts to Durock 1 It should not extend below the height of the noncombustible or equivalent alcove lining ceiling 16 2000893 Smoke and CO Detectors The use of smoke and carbon monoxide CO detectors throughout the home is strongly advised even if not re quired by building codes or insurance regulations It is a good idea to install a smoke detector in the living ar eas and each bedroom Follow the smoke CO detector manufacture s placement and installation instructions and maintain regularly You may not however wish to install a detector in the im mediate vicinity of the stove Depending on the sensitivity of the unit the alarm can be
2. F Resolute Acclaim Woodburning Stove Minimum Wall Shield Requirements for Common Installations A 26 660 mm A 48 1220 mm Bee oe 1118 mm B 36 914 mm C 36 914 mm D 48 1220 mm E 1 25 mm Fig 16 Arear exit stove with reduced rear wall clearance only Fig 19 A top exit stove with a wall shield only no pipe or stove heat shields A 26 wide section of rear wall shield must be cen tered behind the connector A 26 660 mm A 26 660 mm B 44 1118 mm B 49 1245 mm gt T ah mm 44 1118 mm 36 oid a E 43 1092 mm 1 25 mm F 49 1245 mm 23 584 mm Ta G 1 25mm nmo Hou Wot Fig 17 A top exit stove with 90 elbow and no stove or connec Fig 20 A top exit stove with reduced rear and side wall clear tor heat shields Note clearance between chimney connector ances Note that rear wall shield must extend completely to and ceiling corner 6 660 mm 3 584 mm 4 1118 mm 6 914 mm 1 279 mm 3 1092 mm 1194 mm 25 mm 26 660 mm 44 1118 mm 36 914 mm 36 91 4mm RAWBRNMDND 5 127 mm 1 25 mm m mmMoUQOQWDYD TATTMVIODWS 47 1 Fig 21 Atop exit stove with reduced rear and side w
3. 3 Apply a thin 1 8 unbroken bead of stove cement to the newly cleaned groove 4 Starting at one end pack a new gasket into the groove Where the two ends of the gasket meet ensure a good joint before trimming any excess Do not overlap or leave ragged edges Fig 38 Other gaskets form seals between non moving parts but these are not subject to the same wear and deterioration as gaskets on moving parts It is unlikely that you will ever need to replace these gaskets unless the involved parts are disassembled and then put back together In any event this is a job that should be done only by qualified service personnel Fig 38 Lay a bead of gasket cement then press gasket in place 27 Resolute Acclaim Woodburning Stove Gaskets on Resolute Acclaim Stationary Parts 5 16 Between the flue collar and flue collar extension and the stove s top and back 5 16 The seal between the upper fireback corners and the lower fireback 5 16 The seal between the underside of the top plate and the upper edge of the upper fireback 5 16 The damper plate to the reverse side of upper fireback 5 16 The seal between the sealing plates and the vertical ribs of the stove back NOTE When replacing this last gasket after removing the upper fireback place two 2 cap screws into the upper fireback mounting holes before you cement the channels and replace t
4. In Canada this type of installation must conform to CAN CSA B365 Installation Code for Solid Fuel Burning Appli ances and Equipment NOTE Do not vent your Resolute Acclaim into a factory built zero clearance fireplace under any circumstances The Resolute Acclaim has not been specifically tested and listed for this type of installa tion These appliances and their chimneys are specifically designed as a unit for use as fireplaces It may void the listing or be hazardous to adapt them for any other use DO NOT CONNECT THE RESOLUTE ACCLAIM TO ANY AIR DISTRIBUTION DUCT OR SYSTEM 18 457 mm clearance all around the pipe ST494a Fig 10 An approved wall pass through for Canada Floor Protection A tremendous amount of heat radiates from the bottom plate of your Resolute Acclaim The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox Heat protection is provided through the use of a Vermont Castings Bottom Heat Shield 0246 Spark and ember protection must be provided by a floor protector constructed with noncombustible material as specified Most installations will require that the bottom heat shield be attached Only when the stove is placed on a completely noncombustible surface such as unpainted concrete over earth may it be used without the heat shield Even when the bottom heat shield is instal
5. 8 Vermont Castings Group shall have no obligation to enhance or update any unit once manufactured INNO EVENT SHALL Vermont Castings Group BE LIABLE FOR INCIDEN TAL AND CONSEQUENTIAL DAMAGES ALL IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY THIS WARRANTY SUPERCEDES ALL OTHER ORAL OR WRITTEN WARRANTIES Some states do not allow the exclusion or limitations of incidential and consequential damages or limitations on how long an implied warranty lasts so the above limitations may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state How to Obtain Service If a defect is noted within the warranty period the customer should contact a Vermont Castings Authorized Dealer or Vermont Castings Group if the purchase was direct with the following information Name address and telephone number of the purchaser Date of purchase Serial number from the label on the back Nature of the defect or damage Any relevant information or circumstances e g installation mode of operation when defect was noted A warranty claim will then start in process Vermont Castings Group reserves the right to withhold final approval of a warranty claim pending a visual inspection of the defect by authorized representatives Orin gt 149 Cleveland Drive Paris Kentucky 40361 www vermontcastin
6. VERMONT CASTINGS Resolute Acclaim Wood Burning Stove Installation and Operating Manual Model 2490 SAFETY NOTICE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND IN STALLATION INSPECTION REQUIREMENTS IN YOUR AREA NATIONAL We recommend that our woodburning ATA hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Woodburning Specialists or who are certified in Canada by CERTIFIED Wood Energy Technical Wood Energ y wwwaticertiiedorg Haining WETT Technical Training For use in the United States and Canada The French language version of this manual is available online www vermontcastings com La version fran aise de ce manuel est disponible en ligne www vermontcastings com Do Not Discard This Manual Retain for Future Use 2000893 0515 Rev 31 Resolute Acclaim Woodburning Stove Introduction Thank you for choosing a Vermont Castings Resolute Acclaim Your stove is one of the finest available It features high efficiency non catalytic performance using space age refractory materia
7. close the door and damper and reset the primary air within 5 minutes A Surface Thermometer is a Guide to Performance Until you are familiar with how your stove works monitor the griddle surface temperature frequently Use these temperature ranges as general indicators of heat output 350 500 F 177 260 C 500 600 F 260 318 C 600 650 F 318 340 C Low to medium Medium High Stovetop Thermometer Fig 31 A thermometer gives temperature readings that help you to operate your stove safely and effectively Continuous operation at griddle temperatures higher than 650 F 340 C may damage the cast iron parts or the por celain enamel finish of your Resolute Acclaim A surface thermometer can also tell you when to adjust the controls and when to refuel the stove Fig 31 During start up and after re loading for example a ther mometer reading of at least 500 F 260 C signals the stove is hot enough to close the damper and shift into the high efficiency mode Readings lower than 350 F 177 C announce the stove needs loading or it is time to increase the air supply for a higher burn rate At the other extreme a temperature over 650 F 340 C is a warning to slow the burn rate 2000893 Resolute Acclaim Woodburning Stove Rules for Open Fire Viewing WARNING FOR SAFETY AND GREATEST EFFICIENCY OPERATE YOUR STOVE ONLY WITH ALL DOORS GRIDDLES FULLY CLOSED THE TEST STANDARD FOR Y
8. i double wall connec 380 mm 432 mm 380 mm tor Chimney Connector Clearance No Heat Shields Chimney connector heat shields Double wall connector Front Clearance to Combustibles All Installations 48 1220 mm ener with double wall connectors and protected surfaces have not been tested for the Resolute Ac claim A distance of 48 must be maintained between the stove and moveable combustible items such as drying clothes furniture firewood etc When a rear heat shield is installed on a top exit stove the shield insert must be attached to the shield so the area behind the flue collar on the stove is protected 2 Chimney connector heat shields must extend exactly 28 710 mm above the flue collar of the stove No shielding can be used on the connector above 28 710 mm The unshielded chimney connector above the 28 710 mm point will be 14 360mm from an unprotected wall or 8 203 mm from a protected wall 3In top exit installations this clearance requires the use of the rear stove heat shield with the shield insert installed 12 2000893 Unprotected Surfaces Rear Exit Rear Heat Shield Only va uE ie i Y One fe lt 2000893 Resolute Acclaim Woodburning Stove Protected Surfaces
9. material The customer must pay for any in home travel fees service charges or transportation costs for returning the stove to the Authorized Dealer Amount of Time Since Purchase Credit Towards Replacement Cost 0 24 months 100 25 36 months 50 37 48 months 30 49 60 months 20 61 72 months 10 Any replacement catalyst will be warranted under the terms of the catalyst warranty for the remaining term of the original warranty The purchaser must provide the following information in order to receive a replacement catalyst under the terms of this limited warranty 1 Name address and telephone number 2 Proof of original purchase date 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determination of failure 5 In addition the owner must return the failed catalyst VERMONT CASTINGS GROUP Exclusions amp Limitations 1 This warranty is transferable however proof of original retail purchase is required 2 This warranty does not cover misuse of the stove Misuse includes overfiring which will result if the stove is used in such a manner as to cause one or more of the plates to glow red Overfiring can be identified later by warped plates and areas where the paint pigment has burned off Overfiring in enamel fireplaces is identified by bubbling cracking chipping and discoloration of the porcelain enamel finish Vermont Castings Group offers no warranty on chipping of
10. prepare the stove for high efficiency operation Load it with fuel first with smaller splits of wood and then larger ones Close the damper and set the primary air control lever to the HIGH position Operate the stove for 15 20 minutes at this maximum air setting to guarantee the new load of fuel has fully ignited Once the fuel is burn ing steadily you may adjust the primary air supply to provide the desired heat output 20 Damper Control Closed lt Open Fig 30 With the damper closed secondary combustion takes place and the Acclaim operates most efficiently NOTE Effectiveness of a top down method to start a fire Smoke emissions when starting a fire can be difficult to control because the stove is not yet heated to its opti mum temperature One method of reducing emissions during a cold start up is the use of a top down kindling procedure In this place larger pieces of kindling on the bottom of the kindling pile followed by smaller and smaller pieces as the pile is added to Very finely split pieces should be on the top Light the kindling pile with a match at the top and allow the kindling to burn downward into the larger pieces This reduces smoke by slowly increasing the fire size without creating an air starved condition You ll soon find this stove is HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS DO NOT OVERFIRE THIS HEATER Overfirin
11. Whatever kind you use the chimney and chimney connector must be in good condition and kept clean If you use an existing masonry chimney it must be inspect ed to ensure safe condition before the stove is installed Your local professional chimney sweep building inspector or fire department official will be able to make the inspection or to direct you to someone who can The chimney should extend at least 3 914 mm above the highest point where it passes through a roof and at least 2 610 mm higher than any portion of a building within 10 3m Fig 2 0To10 2 Min r 3 a 0T010 Min I 2 Min at Reference Point Fig 2 The 2 3 10 rule for chimneys For proper draft and good performance any chimney used with a Resolute Acclaim should extend at least 16 5m above the flue collar of the stove Masonry Chimneys An inspection of the chimney must confirm that it has a lining Do not use an unlined chimney The chimney also should be examined for cracks loose mortar other signs of deterioration and blockage Repair any defects before the chimney is used with your stove A prefabricated doube wall insulated chimney A tile lined masonry chimney Fig 3 Standard chimney types 2000893 Unused openings in an existing masonry c
12. burn brightly for a short time then let it die out NOTE Some chimneys need to be primed or warmed up before they will draw sufficiently to start a fire To cor rect this situation roll a couple of pieces of newspaper place them on top of the kindling and toward the back of the stove light them and close the doors This should get the smoke moving in the right direction Once the draft is established open the front door and light the rest of the fuel from the bottom Do not light the main bed of fuel until the chimney begins drawing and repeat the procedure as often as necessary if the initial attempt is unsuccessful NOTE Continuous operation with the air control in the start up fully open position may shorten the life of the internal castings 4 Once the fire is burning steadily continue adding fuel until a thick ember bed has been established on the grate The bed must be about 4 102 mm deep at the back of the grate and about 1 25 mm deep at the front and should cover the throat opening into the secondary combustion chamber that is located in the center of the lower fireback If your wood is well seasoned the damper may be closed when the griddle temperature reaches 500 F 260 C Depending on the type of wood being burned and its moisture content it may take several hours to establish and then maintain the ember base that is required for high efficiency operation 5 Once the ember bed is formed
13. chemicals coatings and hardware that may be present can cause damage to the refractory material The best hardwood fuels include oak maple beech ash and hickory that has been split stacked and air dried outside under cover for at least one year Avoid burning cordwood that is over 2 years old as such fuel can contribute to short burn times backpuffing and over firing For areas that do not have a supply of hardwood some of the better softwoods that are commonly burned include tamarack yellow pine white pine Eastern red cedar fir and redwood They too should be properly dried The length 2000893 of the wood should be 16 406 mm Use of wood shorter than 16 may result in decreased burn times Wood should be stored under cover to maintain dryness Even for short term storage keep wood a safe distance from the heater and keep it out of the areas around the heater used for refueling and ash removal Use the Air Control Settings That Work Best for You No single control setting will fit every situation Each op eration will differ depending on the quality of the fuel the amount of heat desired and how long you wish the fire to burn Control settings also depend on your particular installation s draft or the force that moves air through the stove and up through the chimney Draft is affected by such things as the length type and location of the chimney local geography nearby obstructions and other fa
14. e Remove the left and right side firebrick by lifting them approximately 1 2 and swinging the front edge in toward the firebox center Inserting a flat screwdriver blade underneath the brick and lifting will make the removal easier WARNING Handle firebrick with care Protruding steel reinforcement wires could cause injury Rough handling could break firebricks e Remove the two rear firebricks by leaning them forward removing the retainer clip and lifting them out through the griddle opening e Remove both grate sections e Remove the sealing plates by removing the 7 16 hex head bolts and pulling the plate forward Rear Firebricks Retainer Clip Right Fire brick Fig 33 Remove left and right sealing plates e Vacuum debris from both sides of the exposed refrac tory combustion package being careful not to impact the fragile refractory material e Check the gasket which the sealing plates seal against Replace if necessary following the directions for gasket replacement that follow e Replace the grate sections e Replace the sealing plates rear firebricks retainer clip and the side firebricks in that order 25 Resolute Acclaim Woodburning Stove Repair Air Leaks to Prevent Overheating and Excessive Fuel Consumption Adjust the Door Latch The door gasket will compress after use To restore a tight seal adjust the tension on the latch e Remove the Allen hea
15. enamel surfaces Inspect your woodburning stove prior to accepting it for any damage to the enamel 3 This warranty does not cover misuse of the stove as described in the Owner s Guide nor does it cover an stove which has been modified unless authorized by a Vermont Castings Group representative in writing This warranty does not cover damage to the stove caused by burning salt saturated wood chemically treated wood or any fuel not recommended in the Owner s Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to the unit while in transit is not covered by this warranty but is subject to a claim against the common carrier Contact Vermont CastingsAuthorized Dealer from whom you purchased your stove or Vermont Castings Group if the purchase was direct Do not operate the stove as this may negate the ability to process the claim with the carrier 6 Claims are not valid where the installation does not conform to local building and fire codes or in their absence to the recommendations in our Owner s Guide 7 The salt air environment of coastal areas or a high humidity environ ment can be corrosive to the porcelain enamel finish These conditions can cause rusting of the cast iron beneath the porcelain enamel finish which will cause the porcelain enamel finish to flake off This warranty does not cover damage caused by a salt air or high humidity environment
16. floor or on the ground well away from lt all combustible materials lt z pending final disposal Ifthe lt lt ash is disposed of by burial in soil or otherwise locally dispersed it should be retained in the closed container until all cinders have thoroughly cooled Wood ash may be used as a garden fertilizer CAUTION NEVER USE A VACUUM CLEANER TO REMOVE ASH FROM THE STOVE ALWAYS REMOVE AND DISPOSE OF THE ASHES PROPERLY J 22 2000893 Draft Management A stove is part of a system which includes the chimney the operator the fuel and the home The other parts of the system will affect how well the stove works When there is a good match between all the parts the system works well Wood stove operation depends on natural unforced draft Natural draft occurs when the smoke is hotter and therefore lighter than the outdoor air at the top of the chimney The bigger the temperature difference the stronger the draft As the smoke rises from the chimney it provides suction or draw that pulls air into the stove for combustion A slow lazy fire with the stove s air inlet fully open indicates a weak draft A brisk fire supported only by air entering the stove through the normal inlet indicates a good draft The stove s air inlet is passive it regulates how much air can enter the stove but it doesn t move air into it Depending on the features of your installation
17. is also printed on the label Local authorities generally will ac cept the label as evidence that when the stove is installed according to the information on the label and in this manual the installation meets codes and can be approved Codes vary in different areas however Before starting the installation review your plans with the local building authority Your local dealer can provide any additional information needed For any unresolved questions about installation refer to the National Fire Protection Association s publication ANSI NFPA 211 1988 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances In Canada the equivalent publication is CSA CAN B365 Installation Code for Solid Fuel Burning Appliances and Equipment These standards are the basis for many national codes They are nationally recognized and are accepted by most local authorities Your local dealer or your local building official may have a copy of these regulations IMPORTANT FAILURE TO FOLLOW THESE INSTALLA TION INSTRUCTIONS MAY RESULT INA DANGEROUS SITUATION INCLUDING A CHIMNEY OR HOUSE FIRE FOLLOW ALL INSTRUCTIONS EXACTLY AND DO NOT ALLOW MAKESHIFT COMPROMISES TO ENDANGER PROPERTY AND PERSONAL SAFETY What Kind of Chimney to Use Your Resolute Acclaim may be connected either to a sound masonry chimney that meets local codes to a relined ma sonry chimney that meets local codes or to an approved prefabricated metal chimney
18. set off while you are tending the fire or emptying the ashes If you install a detector in the same room locate it as far away from the stove as possible Resolute Acclaim Woodburning Stove Safety Tips Conveniently locate a Class A fire extinguisher to con tend with small fires Be sure the fire extinguisher works and is clearly visible All occupants of the house should know where it is and how it operates Have heavy stove gloves available near the stove Have special safety accessories e g Child Guard Screen available for use if small children will be in the home In the event of a stove pipe or chimney fire Evacuate the house immediately Notify the fire department If the fire isn t too threatening closing down the stove tight damper primary air all doors will help to smoth er the fire Inspect your stove stove pipe and chimney for any damage caused by the fire and correct any damage before using your stove again e e e e You will need the following tools to assemble the Ac claim e 9 16 open end wrench safety glasses amp gloves e flat head screwdriver e power drill w 1 8 3 mm bit e stub handle phillips screwdriver Unpack the Stove 1 Remove the shipping straps and plastic wrap Inspect the stove and contents for shipping damage or missing parts Immediately notify your dealer of any damage Do not install this stove if any damage is evi dent or any parts are missing
19. 005 Removable ash pan Glass panel High temperature ceramic VN AUCcl c a Leeper peerere creer epee terrrer erent prreees 425 lbs 192 kg Width leg to leQ eeeeeeeeeteeeeeeeteteeeeeees 26 660 mm Depth leg to leg o n 19 480 mm Height to top of flue collar w Regular legs 27 699 mm top exit iga riae aged savas aT ai 25 635 mm rear exit W Short legs aaeeea 25 648 mm top exit EA E 23 584 mm rear exit 1294 lt 324 mm A o 1912 495 mm 23 584 mm 25 648 mm 272 LHN 699 mm Cd 26 660 mm Fig 1 Resolute Acclaim dimensions 2000893 Under specific conditions used during EPA emissions testing Efficiency determined by CSA B415 10 This value can vary depending on how the unit is oper ated and the type and moisture content of the fuel used Figure shown is based on maximum fuel consumption obtained under laboratory conditions and on average efficiencies These values are based on operation in building code conforming homes under typical winter climate con ditions in New England If your home is of non standard construction e g unusually well insulated not insulated built underground etc or if you live in a more severe or more temperate climate these figures may not apply Since so many variables af
20. 120 30003121 30003122 30003117 30003123 30003116 30006778 30006779 30006780 30006781 30006782 30006777 30006783 30006776 Brown 30004887 30004888 30004889 30004890 30004891 30004886 30004892 30004885 2000893 31 Warranty Limited 3 Year Warranty Vermont Castings Group warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it except that the catalyst thermostat assembly handles glass door panels cement and gasketing shall be warranted as described below Vermont Castings Group will repair or replace at its option any part found to be defective upon inspection by a Vermont Castings Authorized Dealer The customer must return the defective part or the stove with shipping prepaid to the Authorized Dealer or pay for any Authorized Dealer in home travel fees or service charges for in home repair work It is the dealer s option whether the repair work will be done in the customer s home or in the dealer s shop If upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer for parts and or labor Any woodburning stove or part thereof that is repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to exceed the remaining term of the original limited warranty or
21. 6 Bottom Heat Shield Replacement Parts 0133 Sparkscreen Warranty 3255 Outside Air Adapter for 3 ducting 3249 Mobile Home Kit includes Rear and Bottom Heat Shields Outside Air Adapter Ducting and Leg Clips 0574 Stove Surface Thermometer 3421 Gasket Kit 4360 Griddle Handle Kit Proposition 65 Warning Fuels used in gas woodburning or oil fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm California Health amp Safety Code Sec 25249 6 2 2000893 Resolute Acclaim Woodburning Stove Specifications Resolute Acclaim Model 2490 Range of heat output 9 500 33 900 BTU hr EPA Emissions Rating 3 4g hr Efficiency HHV ccceceeeeeeeeeceeeeeeeeeeeteeeeenaees 12 Maximum heat output ccce 40 000 BTU hr Area heated Up to 1600 sq ft 148 sq m Fuel size type aaccess 16 410 mm wood splits Fuel capacity c s cccesussnececetnenstecteenarecee 30 Ibs 13 6 kg EsTe n1 PEERAERTS Front or top Chimney Connector 6 152 mm diameter Chimney flue size Min 6 152 mm or 8 203 mm Flue exit position cccccccee Reversible top or rear PHUIMANy Alle e6e itelaestc aa a andotceteweaadtes Manual Secondary A 2 ceesshlstceeyaseateaesenttecnavasbdadep ed ssaeteegs Preset Ash handling system
22. Hardware Bag contents e Stove Legs 4 e 3 8 16 x 1 hex head Leg Bolts with washers 4 e Owner s Registration Card e Touch up Paint Porcelain enamel stoves Install Stove Legs Remove and discard the four large slot head screws from the stove bottom Install the stove legs using the hex head bolts from the parts bag Fig 26a Use 3 8 washers with all four legs Tighten the bolts firmly CAUTION Overtightening can strip tapped threads N WARNING This wood heater has a manufactured set minimum low burn rate that must not be altered Itis against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual 2000893 Leg Bolt and Washer Fig 26a Attach stove legs and leg levellers Stove Controls Two Controls Operate the Stove The primary air control lever located beneath the ashlip regulates how much heat the stove produces by control ling the amount of air received by the fire The more air supplied the hotter the fire Fig 27 With a travel range of about 6 159 mm the air control is closed when the lever is fully left Maximum heat is produced when the lever is fully right It may also be set anywhere between a start up position and the high and low extremes to achieve a desired heat output A directional arrow cast into the Acclaim s ash lip serves as a reminder of the correct open and
23. Inner Side Left Side Firebrick Right Side Firebrick Left Shoulder Plate Leg 4 Package Support Plate Bottom Right Shoulder Plate Ashlip Part Number 1201308 See Chart Pg 1602497 1301859 30006590 30006588 30006589 1301851 1301852 1301804 1301806 1601640 See Chart Pg 5005775 1301855 1600153 30004689 1301863 See Chart Pg 1301809 1301854 1301864 See Chart Pg 30 30 30 30 39 40 41 51 52 53 54 55 56 57 58 59 61 62 63 64 65 66 67 68 69 70 Item Description Air Valve Air Valve Shaft Air Valve Handle Door Handle Right Inner Side Right End Damper Handle Stub w Set Screw Damper Handle Damper Handle Screw Air Manifold Front Glass Retainer 2 Glass Door Door Hook Door Handle Shaft Latch Retainer Compression Spring Upper Door Pin C Clip Pin Hinge Bottom Nut Hex 5 16 18 Bracket Side Brick 2 Part Number 1301814 1600621 1600663 1301856 See Chart Pg 30002720 1600664 1201310 1301803 1301861 1601399 1401120 See Chart Pg 1600155 1600623 1201843 1600551 1600550 1600553 1600419 1203279 30006591 30 NOTE For stoves built before May 2013 order Brick Re placement Kit 30006595 Shell Enamel Parts Resolute Acclaim Enamel Left Right Flue Flue Color Top Side Side Collar Cover Leg 1301862 1301857 1301858 1301816 1301817 1301819 1301865 1301833 30003118 30003119 30003
24. OUR STOVE WHEN IT IS OPERATED IN THIS MODE IS UL 1482 YOUR STOVE MAY BE USED AS A FIREPLACE WITH THE FRONT DOOR OPEN OR REMOVED ONLY WHEN THE SPARK SCREEN IS PLACED CORRECTLY IN THE OPENING TO PROTECT AGAINST THE POSSIBILITY OF SPARKS AND EMBERS LEAVING YOUR STOVE THE TEST STANDARD FOR YOUR STOVE WHEN IT IS OPERATED IN THIS MODE IS UL 737 USE ONLY THE RESOLUTE ACCLAIM SPARK SCREEN PART 0133 WITH YOUR ACCLAIM RESOLUTE ACCLAIM SPARK SCREENS ARE AVAIL ABLE FROM YOUR VERMONT CASTINGS AUTHO RIZED DEALER Top Bail Side Clip Fig 32 Angle the screen to seat the top first then push the bottom straight in until the clips snap into place The damper must be open as well whenever you oper ate the Resolute Acclaim in the open fire mode This will prevent smoke and combustion gases from entering the room The spark screen fits inside the arch of the inner stove front and is held in place by a top bail and two side clips Fig 32 To insert the screen place the top bail between the inner front and the air manifold Push with an even pressure on the sides until the clips snap into place The front door may be left on or taken off To remove it open it and retract the spring loaded upper hinge pin Tilt the door slightly and lift it off the lower hinge pin 21 Resolute Acclaim Woodburning Stove Clear the Ash Frequently The slanted grate is designed to shape the charcoal bed to promote high te
25. afe clearances for Resolute Acclaim fireplace installations on Page 11 Floor protection requirements also apply to fireplace instal lations Floor protection is discussed on Page 9 2000893 Resolute Acclaim Woodburning Stove Flexible Con nector Mantel Shield 7 Fireplace Adpator Kit eal AARE i a a ST245 Fig 8 Chimney connector enters chimney through the fire place opening Wall Pass Throughs Whenever possible design your installation so the con nector does not pass through a combustible wall If you are considering a wall pass through in your installation check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Accessories are available for use as wall pass throughs If using one of these make sure it has been tested and listed for use as a wall pass through U S In the United States the National Fire Protection Association NFPA has established guidelines for passing chimney connectors through combustible walls Many building code inspectors follow these guidelines when approving installations The following illustration shows one NFPA recommended method All combustible material in the wall is cut away a sufficient distance from the single wall connector to provide the required 12 305 mm clearance for t
26. aim 2000893 Resolute Acclaim Woodburning Stove Mantel Spacer K 1 25mm C Shield j ja 1 4 6mm Fireplace Mantel and Trim Clearances Measured from the stove top and sides Fig 14 Acustom formed mantel shield Protected Unprotected A Mantel 30 762 mm 36 914 mm B Top Trim 28 711mm 28 711 mm C Side Trim 8 203 mm 8 203 Mmm sT253b Fig 15 Maintain clearances to combustible components of the mantelpiece 2000893 11 Resolute Acclaim Woodburning Stove Resolute Acclaim Clearance Chart Unprotected Surface Protected Surface Parallel Installation Parallel Installation Corner Installation Installation Stove Clearance Corner A 15 B 24 C 15 D 8 E 13 No beat sills 380 mm 610 mm 380 mm 203mm 330mm Top exit roar heat G 15 H 24 I 15 J 8 K 13 shield only 380 mm 610 mm 380mm 203mm 330mm Rear exit rear heat M 15 N 10 N A O 8 P 7 shield only 38 mm 254 mm 203 mm 180 mm Top exit rear h s Q 15 R 15 S 15 T 8 U 9 single wall connector 380 mm 380 mm 380 mm 203 mm 23 mm connector shields 1 Top exit rear h s Q 15 R 17 S 15
27. all clearance Wall shields must meet at corner Fig 18 Atop exit stove with heat shields on both the stove and chimney connector Reduced rear and side wall clearances The chimney connector heat shield must be exactly 28 Note that rear and side wall shields meet at corner 14 2000893 Resolute Acclaim Woodburning Stove Distance from the Center of the Flue Collar to the Wall in Top Exit Installations The information on this page is helpful in planning stove placement for top exiting installations particularly those instal lations with chimneys that pass through the ceiling However this is not a clearance chart Final stove clearances must adhere to the guidelines stated in the Clearance Chart on Page 12 Resolute Acclaim WITHOUT Stove and Chimney Connector Heat Shields Unprotected Surfaces Protected Surfaces Corner Corner Parallel Installations Installations Parallel Installations Installations Rear B Corner C Side D Corner F 26 25 20 15 648 mm 521 mm 381 mm This distance from the center of the flue collar to the front edge of the hearth is the same for all installations on this page 35 in the United States and 37 940mm in Canada Resolute Acclaim WITH Stove and Chimney Connector Heat Shields Unprotected Surfaces Protected Surfaces Corner Corner Parallel Installations Installations Parallel Installations Installa
28. and the decorative side trim on the fireplace face and the top of the stove and the mantel Ventilated shields noncombustible installed on noncom bustible spacers 1 25 mm away from the combustible surface may be used to reduce clearances Fig 14 A mantel shield for the Resolute Acclaim must be at least 48 1219 mm long centered over the stove Side trim shields must extend the full length of the trim Fig 15 An unprotected mantel A Fig 15 must have a minimum clearance of 36 914mm measured from the stove s top plate With a ventilated shield the clearance may safely be reduced to 30 762 mm Maximum depth of the mantel is 9 229 mm Unprotected top trim B protruding 11 2 38 mm or less from the face of the fireplace must be a minimum of 28 711 mm from the stove s top surface This clearance may not be reduced by shielding If top trim protrudes more than 1 38 mm the mantel clearances of 36 915 mm unshielded and 30 762 mm shielded must be used Side trim must have a minimum clearance of 8 203 mm measured from the stove s top side edge In this case venti lated shielding will not provide protection to allow clearance reduction In addition a fireplace installation must observe the floor protection guidelines discussed previously The charts and sample installations on the following pages list the clearances required for various installation configu rations of the Resolute Accl
29. arge self cleaning glass panel The front door may be opened or even removed and the optional spark screen clipped in place for open fire viewing as well 18 Removable Andirons For Greater Front Loading Convenience The andirons slip into pockets cast into the front of the bottom grate and can be removed when loading through the front door Most Acclaim owners however prefer the convenience of smokeless top loading IMPORTANT The andirons must be in place during opera tion Fig 28 They notonly help keepthe glass door panel clear for fireviewing but they assure proper placement of the fuel load for efficient clean burning operation Firebricks Secondary Air Ports Ash Pan Removable Andirons ST612 Bottom Crates Fig 28 A look inside the firebox of the Resolute Acclaim Two Rules For Success Burning wood is said to be more of an art than a science You ll easily master the art if you start by using good dry fuel and understand how the stove s air supply system operates Burn Only High Quality Fuel This heater is designed to burn natural wood only do not burn fuels other than those for which this heater was designed Higher efficiencies and lower emissions generally result when burning air dried seasoned woods as compared to softwoods or freshly cut hardwoods Avoid burning green wood that has not been properly seasoned Also do not use construction materials or trash as fuel the
30. bles but the fit must be O snug and the joint between the thimble and the chimney wall must be cemented firmly Fig 5 A special piece called the thimble sleeve slightly smaller in diameter than standard connector and most thimbles will facilitate the removal of the chimney connector system for inspection and cleaning Thimble sleeves should be available from your local dealer Thimble Sleeve Flue Chimney Connector Keep sleeve end flush with flue tile Fig 5 The thimble made of either ceramic or metal must be cemented securely in place To install a thimble sleeve slide it into the breech until it is flush with the inner flue wall Do not extend it into the actual flue passage as this could interfere with the draft The thimble sleeve should protrude 1 2 25 50 mm into the room Use furnace cement and thin gasketing to seal the sleeve in place in the thimble Secure the chimney connector to the outer end of the sleeve with sheet metal screws naai i 7 0 5 2 5 Flue Liner WAI Slip Pipe Thimble Standard Connector aS Flue Collar Fig 6 Chimney connection is a freestanding installation 2000893 Above A Fireplace In this installation the chimney connector rises from the stove turns ninety degrees and goes back into the fireplace chimney Fig 7 The liner of the fireplace chimney should extend at least to the point at which the chimney connec
31. chimney manufac turer exactly as you install the chimney The manufacturer of the chimney will supply the accessories to support the chimney either from the roof of the house at the ceiling of the room where the stove is installed or from an exterior wall Special adapters are available from your local dealer to make the connection between the prefabricated chimney and the chimney connector The top of such adapters attach directly to the chimney or to the chimney s ceiling support package while the bottom of the adapter is screwed to the chimney connector These adapters are designed so the top end will fit outside the inner wall of the chimney and the bottom end will fit inside the first section of chimney connector When as sembled in this way any soot or creosote falling from the inner walls of the chimney will stay inside the chimney connector Securing the Single wall Connector to a Masonry Chimney Both freestanding masonry chimneys and fireplace masonry chimneys may be used for installation of your Resolute Acclaim Freestanding Installations If the chimney connector must pass through a combustible wall to reach the chimney follow the recommendations in the Wall Pass Through section that follows The opening through the chimney wall to the flue the breech must be lined with either a ceramic or metal cylinder called the thimble which is securely cemented in place Most chimney breeches incorporate thim
32. closed positions Resolute Acclaim Woodburning Stove The damper handle is located on the right side of the stove and controls air flow within the stove Fig 27 The damper is open when the handle is toward the rear of the stove and the combustion gases exit directly out the flue collar When the handle is pulled forward and locked the damper is closed secondary combustion occurs and the stove operates most efficiently The damper must be fully open or fully closed There are no intermediate positions for the damper handle Flue Collar aa O Top Load Door Griddle Damper Handle not shown Griddle Handle Glass Panel Front Door DS Primary Air Control Front Door Handle Fig 27 The Resolute Acclaim controls are conveniently lo cated and easy to use Two Ways to Add Logs and a Choice of Fire Views Convenient top loading of wood through the Acclaim s stovetop griddle supplements traditonal fireplace style loading through the front door The griddle simply lifts to open The front door employs a rotating cam and a door latch tab to secure it The handle points down when the door is closed To open the front door pull on the handle to release the cam To close it push the door until the latch engages Double check the latch by pushing lightly on the handle When the latch is properly secured the door will remain closed For clear fire viewing the front door features a l
33. consid ered to be combustible Keep the Stove a Safe Distance From Surrounding Materials Both a stove and its chimney connector radiate heat in all directions when operating A safe installation requires that adequate clearance be maintained between the stove and nearby combustible materials to ensure that such materials do not overheat Clearance is the distance between either your stove or chimney connector and nearby walls floors the ceiling and any other fixed combustible surface Keep furnishings and other combustible materials away from the stove as well In general a distance of 48 1220 mm must be maintained between the stove and moveable combustible items such as drying clothes furniture newspapers fire wood etc Keeping those clearance areas empty assures that nearby surfaces and objects will not overheat Safe Ways to Reduce Clearances Your stove has special clearance requirements that have been established after careful research and testing to UL and ULC standards Clearance requirements have been established to meet most installation possibilities and they involve the combi nation of four basic variables When the stove has no listed heat shield mounted on it When the stove has a listed heat shield mounted on it e When the wall has no listed heat shield mounted on it e When the wall has a listed heat shield mounted on it In general the greatest clearance is required when you are plac
34. cooling of smoke and reduction in draft especially if they are located outside the home These large chimneys may need to be insulated or to have their flues relined for proper stove performance Accessories to help make the connection between stain less steel chimney liners and your Resolute Acclaim are available through your local dealer Chimney Connector Guidelines Achimney connector is the double wall or single wall pipe that connects the stove to the chimney The chimney it self is a masonry or prefabricated structure that encloses the flue Chimney connectors are used only to make the connection from the stove to the chimney They are for interior use only Double wall connectors must be tested and listed for use with solid fuel burning appliances Single wall connectors should be made of 24 gauge or heavier steel and should be 6 152 mm in diameter Do not use galvanized chimney connector it cannot withstand the high temperatures that can be reached by smoke and exhaust gases and may release toxic fumes under high heat 2000893 Resolute Acclaim Woodburning Stove If possible do not pass the chimney connector through a combustible wall or ceiling If passage through a combus tible wall is unavoidable refer to the recommendations in the section following on Wall Pass Throughs Do not pass the connector through an attic a closet or any similar concealed space The whole chimney connector should be exposed and acces
35. ctors Too much draft may cause excessive temperatures in the stove On the other hand too little draft can cause back puffing into the room and or insufficient heat How do you know if your draft is excessively high or low Symptoms of too much draft include an uncontrollable burn or a part of the stove or chimney connector glowing red Inadequate draft is indicated by smoke leaking into the room through the stove or chimney connector joints In some newer homes that are well insulated and weather tight poor draft may result from insufficient air in the house In such cases it may be necessary to duct combustion air to the stove directly from outside In fact in some areas outside combustion air is required for stove installations in all new construction Your Resolute Acclaim is designed to easily incorporate outside combustion air with a Vermont Castings Outside Air Duct Adapter 3255 available from your local dealer When first using the stove keep track of the air control settings You will quickly find that a specific setting will give you a fixed amount of heat It may take a week or two to determine the amount of heat and the length of burn you should expect from various settings Most installations do not require a large amount of combus tion air especisally if adequate draft is available Do not for any reason attempt to increase the firing rate of your heater by altering the air control adjustment range outlined in th
36. d button screw that attaches the door latch tab to the stove front Fig 34 Remove one of the washers that separates the tab from the front save it for future use Replace the remaining washers and the door latch tab Remove another washer if necessary Test the seal by closing the door on a slip of paper and attempting to pull the paper free If the paper is freed without tearing the gasket isn t snug enough at that spot Washers Door Latch Tab Rotating Cam L Button Screw Allen Head Fig 34 The front door seal can be adjusted simply by adding or removing washers Ifthe paperindicates alow spotina specific area try adjust ing the gasket in that area Pack more cement ora smaller diameter gasket into the channel beneath the gasket so that the main gasket is raised and makes contact with the door frame This procedure should solve the problem If it doesn t replace the gasket following these steps e Wearing safety goggles and a dust mask remove the original gasket by grasping an end and pulling firmly e Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gasket e Apply a thin bead of stove cement in the newly cleaned groove e Pack the gasket into the groove Wait until you are a couple inches from the end before you cut it e Test the gasket by closing the door on a slip of paper such as described above Adjust the gask
37. dering ones You can never be too safe Contact your local fire author ity for information on what to do in the event of a chimney fire and have a clearly understood plan on how to handle one Inspect the Chimney Connector and Chimney Twice Monthly and Clean as Required Let the stove cool completely before you inspect the chim ney Then use a strong light and sight up through the flue collar into the chimney flue If it is not possible to inspect the flue system this way the stove must be disconnected to provide adequate viewing Clean the chimney using a specially designed chimney cleaning brush the same size and shape as the flue liner attached to flexible fiberglass rods designed for this purpose Run the brush up and down the liner so that any deposits fall to the bottom of the chimney where they can be removed through the clean out door The chimney con nector should be cleaned by disconnecting the sections taking them outside and removing any deposits with a stiff wire brush Reinstall the connector sections after cleaning being sure to secure the individual sections with three sheet metal screws per section If you are unable to inspect and or clean the chimney sys tem yourself contact your local dealer or hire a qualified chimney sweep in your area to do the job Resolute Acclaim Maintenance Schedule Stove Daily e Ashes should be removed before they reach the top of the ash pan Check at least onc
38. down The ideal pipe and chimney layoutis straight up from the stove toa completely straight chimney If you re starting from scratch use this layout if possible If the stovepipe must elbow to enter a chimney locate the thimble about midway between the stove top and the ceiling This achieves several goals it lets the smoke speed up before it must turn it leaves some pipe in the room for heat transfer and it gives you long term flexibility for installing a taller stove without relocating the thimble There should be no more than eight feet of single wall stove pipe between the stove and a chimney longer runs can cool the smoke enough to cause draft and creosote problems Use double wall stove pipe for long runs Single Venting Each airtight stove requires its own flue If an airtight stove is vented to a flue that also serves an open fireplace or a leakier stove its easier for the chimney draft to pull air in through those channels than it is to pull air through the airtight and performance suffers Imagine a vacuum cleaner with a hole in the hose to see the effect here In some cases the other appliance can even cause a nega tive draft through the airtight and result in a dangerous draft reversal 23 Resolute Acclaim Woodburning Stove Creosote Creosote is a by product of slow wood burning It s an organic tar that can condense in the flue if its dense in the smoke and slow moving and cools off to less tha
39. e Reversing the Flue Collar Your Resolute Acclaim is shipped with the flue collar in the top exit position Depending on your requirements you may wish to reverse the flue collar and extension plate to the rear exit position The only tool necessary is a 7 16 wrench To reverse the flue collar position 1 Remove the four 4 fasteners that hold the collar and extension plate The fasteners are accessible by reach ing through the flue collar of the stove 10 2 Remove the flue collar and extension plate 3 Examine the exposed gasket contact your Vermont Castings Authorized Dealer if the gasket needs to be replaced 4 Position the extension plate and flue collar in the ap propriate orientation making sure the gasket remains in place The notched edge of the extension plate should be next to the griddle 5 Secure the extension plate and flue collar with the fas teners removed in the first step Run the bolts in only finger tight Adjust the fit of the extension plate and or flue collar if necessary Tighten all four 4 fasteners but do not overtighten them Test the action of the griddle make any needed adjustments by loosening the hardware repositioning the flue collar and extension plate retesting the griddle action and retightening the hardware Fireplace Installations A fireplace installation requires special clearance between the side of the stove and the right and left walls the side of the stove
40. e to creosote buildup in the chimney Draft Testing An easy way to test your chimney draft is to close the stove s damper wait a few minutes to let the airflow stabilize then see whether you can vary the strength of the fire by swinging the air control open and closed Results are not always instant you may need to wait a few minutes for a change in the air control setting to have an effect on the fire If there s no change then the draft isn t strong enough yet to let you close the damper and you ll need to open it for a while longer and manage the fire with the air inlet until the draft strengthens If you keep track of your burn ing habits and relate them to their effects on the stove s operation you ll be rewarded with good performance and a safe system Negative Pressure Good draft also depends on a supply of air to the stove a chimney can t pullin more air than is available to it Sluggish draft results when a house is tight enough to prevent the ready flow of air to the stove or by competition between the stove and other equipment that sends indoor air out side especially power driven equipmentlike range hoods clothes dryers etc If the chimney draws well with all other equipment turned off or sealed in the case of fireplaces and or other stoves then you simply need to be careful with timing the use of the other equipment If you need to crack a nearby window or door to enable the chimney to draw well tha
41. e a day e Keep the area around the stove clear of any combustible material Two Months e Check door handle to be sure it is working properly Gasketing becomes compressed after a period of time e Check leg bolts and heat shield screws tighten if nec essary e Vacuum exhaust area on either side of secondary com bustion package 2000893 Resolute Acclaim Woodburning Stove Yearly Spring Cleaning e Check gasketing for wear and replace if necessary e Vacuum exhaust area on either side of secondary com bustion package e Remove ashes from the ash pan and replace with a moisture absorbing material such as kitty litter to keep the interior of the stove dry e Clean the dust from the inner sides of bottom rear or pipe heat shields if your stove is equipped with them Clean surfaces are better heat reflectors than dirty surfaces e Touch up the black paint Chimney Connector Two Weeks e Inspect the chimney connector and chimney Clean if necessary Two Months e Inspect the chimney and chimney connector Pay particular attention to the horizontal runs of chimney connector and the elbows Clean the system if neces sary Yearly Spring Cleaning e Disassemble the chimney connector and take it outdoors for inspection and cleaning Replace weak sections of connector e Inspect the chimney for signs of deterioration Repairs toa masonry chimney should be made by a professional mason Replace damaged s
42. ections of prefabricated chimney Your local dealer or a chimney sweep can help determine when replacement is necessary e Thoroughly clean the chimney 29 Resolute Acclaim Woodburning Stove Vermont Castings Group reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice Resolute Acclaim Woodburning Stove Model 2490 Item Description Part Number 1 Flue Collar See Chart Pg 30 10 2 Back 1301860 11 3 Damper Rod 1600853 11a 4 Spacer 1201780 12 5 Washer 3 8 1202488 13 6 Damper Ramp 1301811 13a 7 Damper Tab 1601488 14 8 Damper 1301829 15 9 Upper Fireback 1301805 16 30 Item Description Flue Cover Left Griddle Quad Pre 2010 Left Griddle Quad Griddle Right Griddle Quad Pre 2010 Right Griddle Quad Griddle Handle Stub Griddle Knob Bushing Part Number See Chart Pg 30 1301807 30005118 1306356 1301832 30005119 1600881 1600661 1201900 2000893 Resolute Acclaim Woodburning Stove Resolute Acclaim Woodburning Stove Model 2490 continued 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32a 32b 33 34 35 36 37 38 Item Description Griddle Handle Screw Top Combustion Package Sealing Plates 2 Arch Brick Retainer Left Arch Brick Right Arch Brick Rear Grate Front Grate Pit Plate Andiron 2 Tie Rod 4 Left End Ash Pan Left
43. ese directions Use the following air control settings as a starting point to determine the best settings for your needs 2000893 Resolute Acclaim Woodburning Stove Primary Air Settings Air Setting Air Control Position CLOSED Fully Left LOW Approximately 1 25 mm to the right of CLOSED HIGH Approximately 3 80 mm to the right of CLOSED where the lever hits the stop START UP Fully Right High Start up Low Normal Operation O lt lt T Move handle down and to the right for start up position Fig 29 Variable settings for the primary air control between the open and closed positions provide a range of heat output How to Build and Sustain a Wood Fire You can load wood into your Resolute Acclaim through either the top or front loading door Front loading is useful for kindling a new fire but we recommend top loading as the most convenient way of regularly adding several logs at a time Your Resolute Acclaim may be operated with the front door open for fireplace style viewing as well as closed Always be certain the stove damper is open when the door is open and always use the optional firescreen for fire viewing Starting and Maintaining A Wood Fire A new stove needs to be broken in Since cast iron plates expand and contract in response to temperature change let them adjust gradually to heating and cooling To properly break in your stove follow Steps 1 3 below only for your fi
44. et in any areas where an inadequate seal is evident 26 Adjust the Door Although itis unlikely that adjusting it will be necessary the height of the Resolute Acclaim s front load door is adjust able The lower door hinge pin has a shoulder that lifts or lowers the door as you screw the pin up or down Repair Missing Cement in Seams The cement in the stove seams may deteriorate over time and fall out in places Just as with the stove doors it is necessary to keep the seam seals in good condition Spot fix with furnace cement available from your local dealer any areas where the cement seal is visibly deteriorated Allow 24 hours for the new cement to dry Adjust the Damper as Needed The tension of the Resolute Acclaim s torsion bar is adjust able to compensate for compression of the gasket that seals the damper to the damper frame To adjust the damper e Loosen the lock nut on the set screw in the center of the damper Fig 35 e Turn the set screw approximately one half turn clock wise e Re tighten the lock nut and test the damper mecha nism Lock Nut Damper Set Screw Fig 35 When the damper s gasket becomes compressed after prolonged use the damper should be adjusted to regain a tight seal Avoid Damaging the Glass Do not abuse the glass in the front door by slamming the door shut or by striking the glass with a piece of wood and never operate your s
45. fect performance consult your Vermont Castings Authorized Dealer to determine realistic expectations for your home DRAWINGS NOT TO SCALE 25 eget 635 mm 211 546 mm RESOLUTE Acclaim 2112 546 mm Reg Legs 19 495 mm Short Leg 19 483 mm Resolute Acclaim Woodburning Stove Installation SAFETY NOTICE IF YOUR RESOLUTE ACCLAIM IS NOT PROPERLY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT FOR SAFETY FOLLOW ALL INSTALLATION OPERATION AND MAIN TENANCE DIRECTIONS CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLA TION INSPECTION REQUIREMENTS IN YOUR AREA Before you begin an installation review your plans to see that e Your stove and chimney connector will be far enough from combustible material to meet all clearance requirements e The floor protector is large enough and is constructed properly to meet all requirements e You have all necessary permits from local authori ties Your local building official is the final authority for approv ing your installation as safe and determining that it meets local and state codes The metal label permanently attached to the back of every Vermont Castings stove indicates that it has been tested to current UL and ULC standards and gives the name of the testing laboratory Clearance and installation information
46. g can result in permanent damage to the stove If an exterior part of the stove or the chimney connector glows you are overfiring Reloading and Reviving a Wood Fire Reload your stove while it is still hot and there are plenty of embers to re kindle the fire quickly Include some smaller pieces of wood in the new load of fuel to help the stove regain high temperatures quickly Follow this procedure when you reload your stove e Open the damper and move the primary air lever to the HIGH position e Open the front door and check the ash level on the grates and in the ash pan Clear excess ash from the grates particularly at the rear area Level the ember bed Empty the ash pan if necessary e Replace the ash pan and close the front door e Load wood smaller pieces first and close the loading door 2000893 NOTE If the ember bed has burned down to the extent the fire cannot be revived easily it may be necessary to set the air control to the Start up position until the fire has been re established e Allow the stove to regain its thermal momentum before closing the damper This may take 15 20 minutes and will be confirmed by a temperature on the griddle of at least 500 F 260 C e Close the damper and set the primary air lever for the desired heat output NOTE If the remaining charcoal bed is relatively thick and if your fuel is well seasoned it is possible to add fresh fuel smaller pieces first
47. gsgroup com
48. he con nector Any material used to close up the opening must be noncombustible Three other methods are also approved by the NFPA These are e Using a section of double wall chimney with a 9 229 mm clearance to combustibles Resolute Acclaim Woodburning Stove e Placing a chimney connector pipe inside a ventilated thimble which is then separated from combustibles by 6 152 mm of fiberglass insulating material e Placing a chimney connector pipe inside a section of 9 229 mm diameter solid insulated factory built chim ney with 2 51 mm of air space between the chimney section and combustibles Wall Stud Chimney Con nector 12 305mm of Noncombustible Material Floor Pro tection ST493a Fig 9 An approved wall pass through for the United States Canada The Canadian Standards Association has established different guidelines The illustration below shows one method in which all combustible material in the wall is cut away to provide the required 18 457 mm clearance for the connector The resulting space must remain empty A flush mounted sheet metal cover may be used on one side only If covers must be used onbothsides each cover must be mounted on noncom bustible spacers at least 1 25 mm clear of the wall Your local dealer or your local building inspector can provide details of other approved methods of passing a chimney connector through a combustible wall
49. he gasket The new gasket will run inside the cap screws Remove the screws after the gasket cement dries Replacing the Door Gaskets e Lift off the door as described previously Lay it face down on a padded surface e Follow steps 1 4 on gasket replacement as described previously Replacing the Griddle Gasket e Toreplace eitherthe damper orthe griddle gasket follow Steps 1 4 on replacing gaskets described previously Stove front to door 1 2 gasket Grate to stove front 1 2 gasket Glass to door frame 3 16 gasket ST626 Fig 39 Two different gasekt sizes are used to seal the front door 28 5 16 Wire Mesh Gasket 5 16 Fiberglass Gasket ST627 Fig 40 A 5 16 wire mesh gasket seals the griddle to the stove top The flue collar is sealed with a 5 16 fiberglass gasket Replace Broken Firebricks If a firebrick breaks replace only with Vermont Castings custom firebricks available from your local dealer Vermont Castings Group custom firebricks contain metal reinforcements that maintain the brick s integrity if it cracks A brick that is cracked but still intact does not need to be replaced A Clean Chimney System is Safer and Works Better Learn to Recognize Creosote and Soot When you first begin using the stove check daily for creosote a substance that can look like either t
50. heat to the outdoors so it takes less heat from the stove to get it warm and keep it warm 2000893 Resolute Acclaim Woodburning Stove The inside size of a chimney for an airtight stove should match the size of the stove s flue outlet When a chimney serves an airtight more is not better in fact it can be a disadvantage Hot gases cool off through expansion if we venta stove with a six inch flue collar 28 square inch area into a 10 x 10 flue the gases expand to over three times their original size This cools the gases which weakens draft strength If an oversized flue is also outside the house the heat it absorbs gets transferred to the outdoor air and the flue usually stays cool It s common for a masonry flue especially one built for a fireplace to be oversized for an airtight stove It can take quite a while to warm up such a flue and the results can be disappointing The best solution to an oversized flue is an insulated steel chimney liner the same diameter as the stove or insert s flue outlet the liner keeps the smoke at its original volume and the result is a stronger draft An uninsulated liner is a second choice the liner keeps the smoke restricted to its original size but the smoke still must warm up the air around the liner This makes the warm up process take longer Pipe amp Chimney Layout Every turn the smoke must take in its travel from the stove to the chimney top will slow it
51. hick tar or black crisp flakes Experience will show how often you need to clean to be safe The frequency may even vary during the year In the colder months when the hottest fires producing the least creosote are burned you may need to clean less frequently During the warmer months when creosote is more likely to result from cooler burning fires and weaker draft more frequent cleaning may be necessary At the very least inspect the chimney and chimney con nector twice monthly Clean if necessary Let the stove cool to check if a buildup of creosote or soot has occurred If a significant layer of creosote has accumulated 1 8 3mm or more it should be removed to reduce the risk of a chimney fire Failure to keep the chimney and connector system clean can result in a serious chimney fire The conditions for a chimney fire develop like this When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creo sote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire within the flue system which can damage the chimney and overheat adjacent combustible material 2000893 To reduce the amount of creosote that may form remember to provide adequate air for combustion and to strive for small intense fires rather than large smol
52. himney must be sealed with masonry to the thickness of the chimney wall and the chimney liner should be repaired Openings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement In the event of a chimney fire flames and smoke may be forced out of these unused thimbles The chimney should be thoroughly cleaned before use Anewly built masonry chimney must conform to the stan dards of your local building code or in the absence of a local code to a recognized national code Masonry chim neys must be lined either with code approved masonry or precast refractory tiles stainless steel pipe or a code ap proved poured in place liner The chimney s clean out door must seal tightly to help ensure a good draft Prefabricated Chimneys A prefabricated metal chimney must be one tested and listed for use with solid fuel burning appliances to the High Temperature H T Chimney Standard UL 103 1985 2100 F for the United States and High Temperature 650 C Standard ULC S 629 for Canada DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE Chimney Size AResolute Acclaim is approved for venting into a masonry chimney with a flue size of 8 x 8 203 x 203 mm and into a round flue size of 8 203 mm or 6 152 mm It may be vented into larger chimneys as well However chimneys with liners larger than 8 x 12 203 x 305 mm may experience rapid
53. ing a stove with no heat shield near a wall with no heat shield The least clearance is required when both the stove and the wall have heat shields Reducing a stove clearance may require a listed heat shield on the chimney connector as well Resolute Acclaim Woodburning Stove Clearances may be reduced only by means approved by the regulatory authority or in accordance with the clear ances listed in this manual Wall shields should be constructed of 24 gauge or heavier sheet metal or another noncombustible material such as 1 2 13 mm insulation board or common brick laid on flat with the 3 89 mm side down Fig 13 Shields must be spaced out from the combustible surface 1 25 mm on noncombustible spacers The spacers should not be directly behind the stove or chimney connector oa Flow Je Wall Shield Screen Stud Wall Framing Noncombustible spacers and fasteners Ae Shield L Metal Spacer Drywall Ko Air Flow Fig 13 Approved wall shield construction Air must be able to flow between the wall and the shield At least 50 of the bottom 1 25 mm of the shield should be open and the shield must be open at the top When calculating clearance always measure from the top plate of the stove or from the chimney connector itself to the adjacent combustible surface Do not measure from the heat shields of the stove or connector to the combustible surfac
54. l and the precisely calibrated delivery of air to a concentrated charcoal bed to promote secondary combustion in a controlled environment If treated properly and operated according to the guidelines in this manual it will provide years of safe dependable and economical heating The Resolute Acclaim is listed by OMNI Test Laboratories of Portland Oregon The test standards are ANSI UL 1482 and 737 for the United States and ULC S627 for Canada The Resolute Acclaim is listed for burning wood Do not burn other fuels The Resolute Acclaim is listed and approved for installation in mobile homes only in the United States and only with use of Vermont Castings Mobile Home Installation Kit 3249 The Vermont Castings Resolute Acclaim is in compliance with the standards set forth by the Federal Environmental Protection Agency 40 CFR Part 60 532 b 2 as stated on the permanent label attached to each stove In addition to directions on installation and operation this manual includes directions on maintenance and assembly We recommend that you hire a professional solid fuel stove installer to install your stove or to advise you on the instal lation should you attempt to install it yourself Save These Instructions Table of Contents Accessories Specifications Warming Shelf 2 0064 Classic Black Installation 1385 Biscuit Smoke Alarm Safety Tips 1395 Brown Majolica Operation 1397 Bordeaux Maintenance 0184 Rear Heat Shield 024
55. learance chart on Page 12 Single wall Chimney Connectors e Beginning at the flue collar of the stove assemble the chimney connector Insert the first crimped end into the stove s flue collar and keep each crimped end pointing toward the stove Using the holes in the flue collaras guides drill 1 8 83mm holes in the bottom of the first section of chimney connector and secure it to the flue collar with three 3 10 x 1 2 sheet metal screws e Secure each joint between sections of chimney con nector including telescoping joints with at least three 3 sheet metal screws The predrilled holes in the top of each section of chimney connector serve as guides when you drill 1 8 3 mm holes in the bottom of the next section Resolute Acclaim Woodburning Stove e Secure the chimney con nector to the chimney In structions for various instal lations follow e Besure the installed stove and chimney connector are correct distances from nearby combustible mate rial NOTE Special slip pipes and thimble sleeves that form telescoping joints be tween sections of chimney connector are available to simplify installations They often eliminate the need to cutindividual connector sections Consult your local dealer about these special pieces Securing the Single wall Connector to a Prefabricated Chimney Fig 4 The crimped end of the connector points toward the stove Follow the installation instructions of the
56. led you must provide special protection to the floor beneath For instal lations with the heat shield attached use a noncombustible floor protector such as 1 4 non asbestos mineral board or equivalent or 24 gauge sheet metal The floor protector may be covered with a noncombustible decorative material if desired Do not obstruct the space under the heater Protection requirements vary somewhat between the United States and Canada as follows U S installations the floor protector is required under the stove and must extend at least 16 from the front of the stove C Fig 11 and at least 6 from the sides and rear D and E Fig 11 It must also extend under the chimney connector and 2 to either side F Fig 11 To meet these requirements a floor protector must be at least 38 wide and 42 deep In Canada a noncombustible floor protector is required under the heater also The floor protector must extend 18 457 mm to the front C Fig 11 and 8 203 mm from the sides and rear D and E Fig 11 2000893 TE Top Exit Rear Exit Canada 42 1067 mm 46 1168 mm 18 457 mm 3 8 10 Fig 11 Required floor protector dimensions To meet these requirements a floor protector must be at least 42 1067 mm wide and 46 1168 mm deep Floor Protection for Fireplace In
57. lose a third or more of its weight as it dries Also look at the ends of a log as it dries it shrinks and often cracks The more weathered and cracked a piece is the drier it is Dry wood burns readily with a good chimney draft But with modern stoves especially catalytic ones the wood can be too dry While extra dry wood has little creosote in it the remainder can gas out from the wood quickly and densely enough to overload the catalytic burner If you hear a rumbling or roaring noise like a propane torch from the stove that is a sign that the catalyst is seriously overfiring The catalyst is a platinum film on a ceramic base the metal can get to higher temperatures than the ceramic can take and overfiring the catalyst can break it Dry wood can also burn out faster than you want If your dry wood burns out too quickly or overloads the catalyst you can mixin greener wood to slow the fire down 24 Back puffing Back puffing results when the fire produces volatile gases faster than the chimney draft pulls them out of the firebox The gases back up in the firebox till they re dense enough and hot enough to ignite If your stove back puffs you should open up the damper to let the smoke rise to the flue more quickly let more air into the firebox and avoid big loads of firewood Run your stove with enough primary air so that you always see lively dancing flames in the firebox a lazy smoky fire is inefficient and can contribut
58. mperatures near the entrance to the secondary combustion chamber The grates must be kept free of heavy ash accumulation Clear ash manually every six to eight hours of operation or before you reload To clear the ash hoe the ash and charcoal forward with a stove shovel or similar fireplace tool so they drop through the grate CAUTION Do not put any tool up into the sec ondary combustion chamber or you will risk damaging the refractory package Remove and Store Ash Safely Check the ash pan before reloading the stove If the ash is close to the top empty the pan Before replacing the ash pan clear away any ash that has spilled over the sides and back of the pan When burning wood empty the ash drawer regularly typically every one to three days The frequency will vary depending on how hot you run your stove the hotter the fire the more wood you burn and the faster ash will ac cumulate The ash pan is located in the ash drop chamber with a handle attached to the front and one to the rear Always use stove gloves when handling the ash pan Keep it level and carry it outside for disposal Empty the ash into your ash disposal container When you are finished slide the pan back into the stove Ash may contain hot coals and must be treated with extreme care It should be removed frequently and placed outdoors in a metal container with a tight fitting lid The closed container of ash should be placed on a non combustible
59. n 290 F Condensed creosote is volatile and can generate chimney fires if it gets hot enough All the features that affect chimney draft also affect creosote condensation so use whatever combination of installation features and operational steps will encourage good draft and minimize creosote production Because letting the smoke cool off and slow down is one of the keys to creosote production it makes sense to line a chimney to match the stove s outlet size for safety reasons as well as performance Canadian law requires a matching liner to serve any stove or insert vented through a fireplace chimney in the US the National Fire Protection Association recommends one if the flue is more than three times bigger in square area than the outlet on the stove or insert Some localities enforce the NFPA guidelines as part of their building codes Even the best stove installation will not perform well with poor fuel The best fuel is hardwood that has air dried 12 18 months Softwood burns but not as long as hardwood Fairly green wood has a good amount of moisture in it it will burn but some of the heat potential is used to drive the remaining moisture off the wood This reduces the amount that reaches your home and can contribute to a creosote problem There are moisture meters available for firewood you can also judge your wood by its appearance and weight If you get it green lift a piece and get a sense of its weight it can
60. ol completely then buff with a damp soft rag Dry completely before start ing a fire so that water drops or wet streaks will not leave marks Never use abrasives or harsh chemical cleaners on the porcelain enamel finish To remove stains or spills from porcelain enamel first make sure that the stove is completely cool Use only a kitchen appliance cleaner or polish recommended for enamel surfaces Apply sparingly with a soft rag and buff away all traces of the cleaner Cleaning the Glass Most of the carbon deposits on the glass will burn off regu larly during hot fires If you wish to clean the glass more thoroughly follow this procedure e Let the stove and glass cool completely e Wash the glass with warm water and a soft paper towel or rag Rinse and dry thoroughly Never use abrasives ashes or harsh chemicals to clean your Resolute Acclaim glass For stubborn deposits use a ceramic glass cleaner avail able from your Vermont Castings Authorized Dealer Do not allow the cleaner to touch brass ornaments or porcelain finish 2000893 Resolute Acclaim Woodburning Stove Maintenance Clean the Exhaust Channels The firebricks and sealing plates should be removed and the exhaust area on either side of the secondary combus tion package should be vacuumed carefully at least once a year or after every 60 days of sustained burning Follow these steps e Remove the ashpan the griddle and the andirons
61. place Gaskets The Resolute Acclaim uses rope type fiberglass gaskets to make a tight seal between some parts With use particu larly on those parts that move gaskets can become brittle and compressed and can begin to lose their effectiveness These will need periodic replacement All of the gaskets used are made of fiberglass The three sizes of replaceable gasket are listed below along with their application 2000893 Resolute Acclaim Woodburning Stove Resolute Acclaim Gaskets on Moving Parts Gasket Size And The Parts It Seals 3 16 The glass to the load door frame 5 16 wire mesh The griddle to the stove top 1 2 The arch and bottom edge of the inner front stove panel to the front load door 1 2 The front of the grate to the front load door Should you need to change a replaceable gasket wait until the fire is out and the stove has cooled Be sure to follow the standard safety procedure for working with dusty materials wear safety goggles and a dust mask The procedure for replacing gaskets is the same regardless of the gasket location Four easy steps are involved 1 Remove the existing gasket by grasping an end and pulling firmly Fig 37 2 Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gasket Use a cold chisel for stubborn deposits ae ST560 Fig 37 Remove gasket then clean channel with wire brush
62. rst three or four fires After that you may go on to Step 4 and normal operation of the stove The stove paint and cement will emit a slight odor during the first few fires We suggest that you provide extra ventilation near the stove by partially opening a door or window when the odor is present WARNING Operate only with doors fully open or doors fully closed If doors are left partly open gas and flame may be drawn out of the fireplace stove opening creat ing risks of both fire and smoke 1 Open the stove damper and open the primary air control fully to the Start up position 19 Resolute Acclaim Woodburning Stove 2 Lay some crumpled newspapers in the stove Place six or eight pieces of dry kindling split to a finger width size on the paper and on the kindling lay two or three larger sticks of split dry wood approximately 1 2 25 50 mm Do not use chemicals or fluids to start the fire Do not burn garbage or flammable fluids such as gasoline naptha or engine oil Also never use gasoline type lantern fuel Kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use 3 Light the newspaper and close the door The fire soon will be well established and you may gradually build it up by adding a few sticks at a time of a progressively larger size For your initial three or four break in fires let the fire
63. sible for inspection and cleaning Install the chimney connector not less than 23 584 mm from the ceiling Keep it as short and direct as possible with no more than two 2 90 turns If possible use 45 elbows Slope horizontal runs of connectors upward 1 4 per foot 20 mm per meter going from the stove toward the chimney The recommended maximum length of a hori zontal run is 3 914 mm and the total length of chimney connector should be no longer than 8 2 5 m In cathedral ceiling installations extend the prefabricated chimney downward to within 8 2 5 m of the stove SAFETY NOTE ALWAYS WEAR GLOVES AND PRO TECTIVE EYEWEAR WHEN DRILLING CUTTING OR JOINING SECTIONS OF CHIMNEY CONNECTOR Double wall Chimney Connectors The listing for the Resolute Acclaim in the U S and Canada includes use of double wall chimney connectors that have been tested and listed for use with solid fuel burning ap pliances by a recognized testing laboratory Information on assembling and installing double wall con nectors is provided by the manufacturer of the double wall pipe Follow the manufacturer s instructions exactly as you assemble the connector and attach it to the stove and chimney Using chimneys and connectors from the same manufacturer helps make the assembly and installation straightforward NOTE For installations using double wall connectors minimum clearances must conform to the listed clear ances in the c
64. six 6 months whichever is longer Limited 1 Year Warranty The following parts of the woodburning stove are warranted to be free of defects in material and workmanship for a period of one year from the date you receive it The thermostat assembly handles glass door panels cement and gasketing Any of these items found to be defective will be repaired or replaced at no charge upon the return of the part with postage prepaid to a Vermont Castings Authorized Dealer Any part repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period not to ex ceed the remaining term of the original limited warranty or six 6 months whichever is longer Limited Catalyst Warranty The catalyst will be warranted for a six year period as follows Ifthe original catalyst or a replacement catalyst proves defective or ceases to maintain 70 of its particulate emission reduction activity as measured by an approved testing procedure within 24 months from the date the stove is received the catalyst itself will be replaced free From 25 72 months a pro rated credit will be allowed against a replace ment catalyst and the cost of labor necessary for its installation at the time of replacement For stove purchases made after June 30 1990 a third year 25 36 months of no charge replacement will be made when combustor failure is due to thermal degradation of the substrate crumbling of ceramic
65. stallation Do not assume that your fireplace hearth is completely noncombustible Many fireplace hearths do not satisfy the completely non combustible requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing as in Figure 12 Because heat passes readily through brick or concrete it can easily pass through to the wood As a result such fireplace hearths can be a fire hazard and are considered a combustible floor For all fireplace installations follow the floor protection guidelines described above Keep in mind that many raised hearths will extend less than the required clearance from the front of the heater when it is installed In such cases sufficient floor protection as described above must be added in front of the hearth to satisfy the minimum floor protector requirement from the front of the stove 16 410 mm from the front in the United States and 18 457 mm from the front in Canada Hearth rugs do not satisfy the requirements for floor protec tion as they are not fire proof Fireplace installations also have special clearance require ments to the side walls side decorative trim and fireplace mantel Refer to the information on fireplace and mantel trim shields in this section 2000893 Resolute Acclaim Woodburning Stove Wood framing requires protection from radiant heat ST247a Fig 12 Supporting timbers under fireplace hearth are
66. steel or masonry chimney inside or outside the house matched to the stove s outlet or oversized your system may warm up quickly or it may take a while to warm up and operate well With an airtight stove one which restricts the amount of air getting into the firebox the chimney must keep the smoke warm all the way to the outdoors Some chimneys do this better than others Here s a list of features and their effects Masonry Chimney Masonry is a traditional material for chimneys but it can perform poorly when it serves an airtight stove Masonry is a very effective heat sink it absorbs a lot of heat It can cool the smoke enough to diminish draft The bigger the chimney the longer it takes to warm up It s often very difficult to warm up an outdoor masonry chimney especially an oversized one and keep it warm enough to maintain adequate draft Steel Chimney Most factory made steel chimneys have a layer of insula tion around the inner flue This insulation keeps the smoke warm The insulation is less dense than masonry so the inner steel liner warms up more quickly than a masonry chimney Steel doesn t have the good looks of masonry but it performs much better Indoor Outdoor Location Because the chimney must keep the smoke warm it s best to locate it inside the house This uses the house as insulation for the flue and allows a little heat release into the home An indoor chimney won t lose its
67. t s a sign that you should install an outside air intake to bring combustion air directly to the stove Vermont Castings Group dealers carry adapters to attach to the stove to connect an air duct for outdoor combustion air Conclusion Wood burningis an art rather than a science Once the stove and chimney system are in place the stove user can only vary technique mostly your timing to achieve good results If you keep track of your burning habits and relate them to their effects on the stove s operation you ll be rewarded with good performance and a safe system 2000893 Keep Your Stove Looking New and Working Its Best Care of the Cast iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Resolute Acclaim looking new A damp cloth may be used as well but only when the stove is cool Make sure no water remains on the stove surface If the paint needs retouching allow the stove to cool com pletely Wire brush areas needing to be painted Remove non painted components such as air controls or cover them with masking tape Touch up the stove with high temperature stove paint available from your local dealer Apply the paint sparingly Two light coats are better than one heavy one Care of the Porcelain Enamel Surface Use a dry rag or a soft brush Do not use water or other liquids Fingerprints usually can be buffed off with a dry soft rag If marks remain allow the stove to co
68. tions Corner C Side D Corner F 25 20 648 mm 521 mm ST608a To locate center of flue collar for corner installation add 10 270mm to the clearance distance from stove corner to wall Mark off the resulting distance from the corner along both walls Next measure the same distance from these two points out from the walls These last two measurements will meet at a point representing the center of the flue collar Refer to the dia grams above 2000893 15 Resolute Acclaim Woodburning Stove Alcove Installations Because of their restricted air flow and heat retention characteristics specific construction requirements and special clearances apply to installations into alcoves No stove or chimney connector heat shields are used in alcove installa tions Bottom heat shield requirements remain the same as for other installations ALCOVE INSTALLATION OF THE RESOLUTE ACCLAIM IS NOT PERMITTED IN CANADA Construction Requirements Joist Shield Showing noncombustible ceiling framing and maximum supplied A by chimney and minimum permitted dimensions manufac turer 1 air gap top Combustible and bottom facing may on both sides and back A metal studs wall by only 1 7 16 Durock or equivalent Fig 25 Alcove side section
69. tor enters the chimney Follow all the guidelines for installing a chimney connector into a freestanding masonry chimney and pay special attention to these additional points e Ifthere is a combustible mantel or trim check the stove and chimney connector clearances Use the necessary combination of mantel trim and connector heat shields to provide the required clearances e Double check connector clearance from the ceiling e The fireplace damper must be closed and sealed to prevent room air from being drawn up the flue reducing the draft However it must be possible to reopen the damper to inspect or clean the chimney Chimney Con nector Shields Check these clearances Seal the Damper Fig 7 Chimney connector enters chimney above the fireplace Through A Fireplace If your fireplace opening height is at least 23 584 mm you may install a Resolute Acclaim through the opening using a positive connection kit available from your local dealer These kits provide a secure connection between the stove flue collar and the chimney flue Fig 8 If it is necessary to reverse the flue collar from the top exit to the rear exit position follow the directions on Page 10 Fireplace installations whether connected to the flue above or through the fireplace opening have special clearance requirements to adjacent trim and the mantel You ll find the required s
70. tove if it has damaged or broken glass If you need to replace the glass use only glass provided by Vermont Castings Group 2000893 Replace Broken Glass Immediately Do not operate the ResoluteAcclaim ifthe glass is damaged Use the following procedure for glass replacement NOTE Replace glass with Vermont Castings Group replacement glass only available from your local dealer e Open the door and carefully remove the glass by remov ing the two 2 clips one per side that hold the glass panel against the gasket in the arched door opening Each clip is held in place with two 2 Phillips truss head machine screws Fig 36 Retainer Clip 3 16 Gasket Fig 36 Glass replacement Examine the gasket that seals the glass to the door frame Replace if necessary with gasket obtained from your local Vermont Castings Authorized Dealer e The glass used in your Resolute Acclaim is specially coated on one side with a heat reflecting material Examine the replacement glass panel and notice the markings along the edge e Center the replacement glass panel in the arched door opening with the marked side of the glass panel facing the gasket There should be a gap to allow for expansion and contraction between the edge of the glass panel and the cast iron e Replace the two retainer clips and fasten with the previ ously removed screws Tighten the screws slowly and evenly do not overtighten How to Re