User`s ManUal - Ness Corporation
Contents
1. DELUXE D8x D16x Deluxe USER S MANUAL Hardware amp Firmware v8 0 f amp S LCD K Document 890 016 or KPX amp Saturn eypads Raw O Refer to document 890 402 Navigator Manual for operation by Ness Navigator Touch Screen keypad EG CORPORATION Innovative Electronic Solutions www ness com au MADE LN AUSTRALIA National Customer Service Centre Ph 1300 551 991 customerservice ness com au D8X D16X DELUXE USER S MANUAL FOR LCD KEYPADS Document Part No 890 016 Rev 1 0 February 2015 For use with Ness D8x D16x DELUXE control panels V8 0 and later This manual can also be used for previous versions of D8x D16x panels however some of the programming options covered are available only in V8 0 and later Refer to user manual 890 006 for D8x D16x V7 8 and earlier Refer to Navigator user manual 890 402 for touch screen keypad operation WARNINGS amp NOTICES Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been applied during manufacture to ensure the reliable operation of this product However there are various external factors that may impede or restrict the operation of this product in accordance with the product s specification These factors include but are not limited to 1 Erratic or reduced radio range if radio accessories are installed Ness radio products are sophisticated low power devices however the
2. Enter a value between 1 and 7 1 Sunday 3 New VALUE Enter the new time in The new time will be dis seconds Example enter 25 played by the keypad one seconds as 25 E digit at a time 4 OP To exit User Program Mode ue Program light will turn Set the current date and time to ensure that AutoTime events take place as expected You will need to adjust the Hours setting when Daylight Savings starts and ends Clock memory is retained on power down 24 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL MONITORING CENTRAL STATION MONITORING The Ness D8x and Ness D16x control panels the users who arm and disarm the system have an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify For further information about 24 hour monitoring contact your installer or Ness Corporation AUDIBLE VOICE MONITORING ENHANCED D8x D16x version 8 0 and later has exhanced audible monitoring features using an onboard library of voice messages to deliver clear and concise spoken word alarm messages to the recipient s mobile phone or landline Audible message
3. To control OUTPUTS press 2 To exclude or include a zone press 3 To listen to reports press 4 To hang up press STAR then press HASH The user presses STAR then HASH then to hangup NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 27 NESS ACCESSORIES mm kd CL mange THT AUD uf f TT Guu an mE NESS DETECTORS The Ness Quantum range of high tech motion detectors includes passive infrared detectors dual technology microwave and infrared as well as ceiling mounted 360 detectors All Ness detectors are designed and manufactured using the most modern technology and techniques to ensure superior reliability and performance The Ness Quantum Pet Aware PIR and Pet Aware Dual have a superior ability to discriminate between household pets and unwanted human intruders Ness Pet Aware detectors make it possible to protect your premises with your pets indoors Up to 25kg animal Pon AUSTRALIA Le v CCTV Products NESS CCTV PRODUCTS The wide range of Ness CCTV equipment allows your installer to design a professional state of the art system for your home office shop or factory Ness cameras include analogue or IP based dome cameras Infra red illuminated cameras miniature hidden cameras and professional digital cameras Ness DVRs are available in 4 8 or 16 channel models in standard definition or full 1080p HD for high definition surveillance and recordin
4. Zones As an extra feature the user can easily enable or disable Day Mode which includes both Temporary and Permanent Day Zones Day Zones can be programmed by your installer to beep the keypad or briefly sound the siren s or flash the strobe light or to sound an optional buzzer Although the keypad beeper provides sufficient warning in most situations TYPICAL APPLICATIONS Day Zones are useful for a variety of applications such as a shop door beeper triggered by a reed switch on the door For example in a shop you could enable Day Mode to alert you when a customer enters the front door You can also enable additional Temporary Day Zones to monitor switches on for example the rear door or the fridge doors TEMPORARY DAY ZONES COMMANDS Accessed from normal operating mode Enter Selection Mode P E Press P followed by E when in operating mode to enter Temporary Day Zone selection mode Zone Selection Zone No To select or deselect zones to be Temporary Day Zones The selected zones are indicated by the corresponding zone number Permanent Day Zones installer option P53E are not displayed in selection mode Permanent Day Zones can be selected as Temporary Day Zones but this has no effect as those zones are already day zones Exit Selection Mode Saves changes and returns to normal operating mode Enable Day Mode ORG This enables disables both Temporary and Permanent Day
5. 1 Master Cove E DESCRIPTION Enters User Program Mode COMMENT The Program light will turn on 2 P OPton No Enter the 3 digit option number for the user code being pro grammed The existing user code if any will be displayed by the keypad one digit at a time 3 New Cope HE New Cove E Enter the new user code twice for verification Keypad codes can be 3 6 digits long User codes must NOT start with zero The new user code will be displayed by the keypad one digit at a time ORO To exit User Program Mode The Program light will turn off A keypad code can be deleted by pressing E at STEP 3 above Q A keypad code only needs to be deleted if you re not replacing it with a new code EXAMPLES The panel must be in program mode e To program User Code 1 to be 1234 Press P201E 1234 E 1234 E e To delete User Code 2 without programming a new code P202E MEMORY E USER CODE PROGRAMMING RULES Up to 56 Keypad Codes can be used at up to 3 wired keypads for controlling all panel functions including Arming Disarming Home Mode Panic memory recall and much more e Keypad Codes can be 3 to 6 digits in length and can be individually programmed and deleted e User Code 1 is also the Master Code which is used to enter Client Program mode e All 56 User Codes are Keypad Codes by default User Codes can be programmed to be Radio Codes or A
6. Ask your install to check the installer level programming settings and reprogram the system to suit your needs 18 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPERATION AUTO TIME OPERATION WARNING PERIOD Optional function must be enabled by your installer When an AutoTime event is about to begin your keypad or keypads will begin a constant slow beep as a warning that the automatic event is about to happen The warning beeps can be programmed to start up to 99 minutes prior to the AutoTime event Press any key on the keypad to stop the beeps during the warning period The beeps will start again for the final minute at a faster rate FINAL MINUTE BEEPS In the last minute prior to the AutoTime event the keypad will beep at a faster rate to warn that the event is about to start TO DELAY THE AUTOTIME EVENT Optional function must be enabled by your installer To delay the AutoTime event enter a valid user code on its own The user code must be assigned to an Area to work This will suspend the warning beeps and the AutoTime event for 1 hour when the warning process will start again Example Your panel is programmed to Auto Arm at 6pm every weekday and the Warning Period is programmed for 5 minutes You are working back late and at 5 55pm your keypad begins to beep Since you re not ready to arm the system yet enter your user code without pressing E at the keypad The warning beeps will stop and arming will be
7. LCD KEYPAD The Ness LCD keypad uses a large illuminated LCD display to Sa show system and zone status The large easy to read buttons mae are backlit for and a hinged flap covers the keys 2 e The LCD icon display provides information on zone condition armed state mains and battery condition and other information NESS SATURN KEYPAD Proving that alarm keypads can be beautiful as well as functional Saturn s elegant design adds a distinctive look and feel of luxury to your alarm system Available in White Black and Ocean Mist Saturn keypads are fully compatible with Ness D8x D16x control panels version 6 and later NESS RADIO KEYS The optional Ness Radio Keys give you the convenience of remote control operation Multi button operation allows you to Arm Disarm and activate PANIC and AUX outputs RK4 radio key The RK4P model also has a proximity fob built in providing radio remote and access control in the one radio key NESS ACCESS CONTROL D8x and D16x also have an access control option for arming disarming and controlling electric door locks The panels have built in software and hardware support for up to 3 Ness Weigand proximity card readers and up to 55 proximity cards or fobs NESS iCOMMS and aCOMMS app for mobile control of your D8x D16x control panel from home office anywhere in the world using your iPhone iPad or Android device Arm Disarm e View zone status e Emergency alarms e Control the panel
8. Zones When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone Q The MONITOR icon flashes continuously when Temporary Day Mode is enabled NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL Ed OPERATION AUTO TIME FEATURES D8x D16x V6 onwards features sophisticated new automation features making full use of the onboard Real Time Clock and a set of powerful yet simple to program options I AUTO TIME amp ARMED A ARMED Ti HOME ARM or DISARM AUTOMATICALLY at pre programmed times of day or day of the week This feature can save a site manager many headaches and hours of travel time There is no need to rely on staff remembering to arm or disarm the system TURN AUX OUTPUTS ON or OFF at pre programmed times every day once a week anytime Automate doors sprinkler systems lights and more CJAUTO Cur ENABLE DISABLE USER CODES depending on the time of day or day Y of the week Allows managers to grant users access to the system at N selected times and deny after hours entry This applies to keypad codes only not radio keys or prox fobs If you find that the panel sometimes does not respond to user codes or the panel arms N or disarms itself or auxiliary outputs turn on automatically then your panel may have been programmed for AutoTime events
9. again if needed Using the optional Radio Keys you can enter Home Mode by pressing either the OFF button or the ON button twice within 4 seconds or by pressing the AUX button RK4 radio key only These options must be enabled by your installer vee OP GYS Press either the OFF button or the ON button twice within 4 seconds Or press the AUX button once If enabled RK4 radio key only The strobe light will flash briefly If required your installer can program the external siren to chirp twice when arming Home mode Note Home Mode and Area arming Home Mode can be used if the panel is fully disarmed or if only Area2 is armed Home Mode is not available when Area 1 is armed The panel can be armed in Home mode if Area2 is already armed on these conditions e Area 1 must be OFF e Area 2 must be armed first and then Home Mode armed not the reverse e Zones assigned to both Home mode and to Area 2 will act as Home Mode zones when both Area 2 and Home Mode are armed Note Home Mode arming when Area2 is armed cannot be done by Radio Key or by keyswitch mm NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPERATION PANIC alarm by KEYPAD Press QD CD star keys together or press C User Cone E or press D E If KEyPAD Panic SHORTCUT is enabled The keypad PANIC function may have been programmed to be either AUDIBLE to activate the sirens or SILENT
10. delayed by one hour At 6 55pm the warning beeps will start again followed by automatic arming if you don t delay the event again Any AutoTime event can be postponed not just arming You can also delay the automatic turn or off of one of the AUX outputs in the same manner MANUAL OPERATION OF THE AUX OUTPUTS Optional function must be enabled by your installer As well as automatic operation by Auto Time the four auxiliary outputs can also be operated manually by keypad Use the keypad commands below to turn outputs on or off or pulse on To turn ON or PULSE To turn OFF AUX1 OOD DOS AUX2 oIoKa D WOK E AUX3 VOC OJOK E2 AUX4 OOK Y WS AUX5 6 7 amp 8 operate as described above ie Press 55 66 etc N Manual operation of outputs works in conjunction with AutoTime schedules if programmed For example if AutoTime has turned an output on as scheduled say a light you can manually turn it off and back on again any time you wish At the scheduled turn OFF time if the output is still on it will be turned off 1 Whether an output Pulses or Turns On depends on the how that output has been programmed by your installer NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 19 PROGRAMMING Programming your Ness D8x or D16x is a simple process using the keypad To enter program mode you need to know your Master Code which is user code number 1 see the table on the next page
11. flashing Cannot arm and the EXCLUDE light is on steady A zone s has been Excluded You are in Exclude mode This is to indicate that one or more zones have been Excluded Press E to exit Exclude mode TAMPER light flashing The 24 hour Tamper input has alarmed Siren tamper or box tamper Call your installer ALARM MEMORY light is flashing There are alarms in memory To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you arm the panel Cannot enter Program Mode The panel is armed Or you may be attempting to enter program mode using one of the user codes Disarm the panel before attempting to enter Program Mode Try again using the Master Code When arm by radio key the Armed light on the keypad does not turn on immediately The panel is waiting 5 seconds for a second press of the ON button to enter Monitor mode This is normal operation when arm ing of Monitor mode by radio key is enabled The keypad is making a continuous slow beep This is the AutoTime warning beep which can be programmed to start from 1 to 99 minutes before an AutoTime event is due to begin The beeps will continue during the AutoTime warning period changing to faster beep in the final minute prior to the AutoTime event The panel re arms itself a short time after disarming Auto Re Arm is enabled Enter the premises after disarm
12. of an alarm When you delete the Follow Me Telephone Number alarm calls will again be made to the Primary and secondary telephone numbers If your Ness panel is monitored by a Central Station the Follow Me number is ignored For all other programming changes talk to your installer 20 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL PROGRAMMING OPTIONS TABLE USER CODE OPTION NO KEYPAD PIN USER CODE OPTION NO KEYPAD PIN 1 Master Code P201E 123 29 P229E 2 P202E 30 P230E 3 P203E 31 P231E 4 P204E 32 P232E 5 P205E 33 P233E 6 P206E 34 P234E 7 P207E 35 P235E 8 P208E 36 P236E 9 P209E 37 P237E 10 P210E 38 P238E 11 P211E 39 P239E 12 P212E 40 P240E 13 P213E 41 P241E 14 P214E 42 P242E 15 P215E 43 P243E 16 P216E 44 P244E 17 P217E 45 P245E 18 P218E 46 P246E 19 P219E 47 P247E 20 P220E 48 P248E 21 P221E 49 P249E 22 P222E 50 P250E 23 P223E 51 P251E 24 P224E 52 P252E 25 P225E 53 P253E 26 P226E 54 P254E 27 P227E 55 P255E 28 P228E 56 P256E OPTION NO DESCRIPTION DEFAULT COMMENT P26E Entry Delay Time 1 20 20 sec P27E Entry Delay Time 2 6 60 sec This option works in multiples of 10 6 60 sec P28E Exit Delay Time 60 60 sec POOE Follow Me Phone No blank NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL BI PROGRAMMING Programming USER CODES STEP KEYSTROKES
13. panel during an alarm message METHOD 2 The connection is initiated by the user phoning the panel HOW TO INITIATE TELEPHONE REMOTE CONTROL 1 Phone the panel telephone number and listen for the required number of rings the normal double ring is counted as one ring and then hang up 2 Wait 10 seconds and then call the number again within 50 seconds 3 The panel will answer the second call immediately and respond with an audible tone similar to a fax tone 4 Press the 2 button on your telephone to start the session 5 Listen to the voice prompts for instructions 6 When you re done press to hang up TELEPHONE REMOTE CONTROL for V8 0 and later Remote operation allows 1 Control of Arming Disarming AUX 1 to AUX 8 and Zone Excludes 2 Voice updates on Arming state Zone alarm and excluded state warning states Prompts would be issued when one of these is changed OPERATION Example When the user calls the panel using the accepted methods and after the panel stops sending the answer tone sequence The user first presses key 3 and the panel starts the voice prompt This is your SECURITY SYSTEM To control the security system press STAR then enter your USER code then press HASH If the user does this correctly then the voice prompt continues d To arm or disarm the system press 1 To control OUTPUTS press 2 To exclude or include a zone press 3 To listen to reports pre
14. 01E 20 P220E 2 P202E 21 P221E 3 P203E 22 P222E 4 P204E 23 P223E 5 P205E 24 P224E 6 P206E 25 P225E 7 P207E 26 P226E 8 P208E 27 P227E 9 P209E 28 P228E 10 P210E 29 P229E 11 P211E 30 P230E 12 P212E 31 P231E 13 P213E 32 P232E 14 P214E 33 P233E 15 P215E 34 P234E 16 P216E 35 P235E 17 P217E 36 P236E 18 P218E 37 P237E 19 P219E 38 P238E NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL El KEYPAD OPERATION SUMMARY Operation by KEYPAD to ARM The panel must initially be disarmed to DISARM To disarm and or reset alarms to arm HOME MODE The panel must initially be disarmed See page 12 for more information on arming Home Mode PANIC alarm KEYPAD DURESS Keypad Duress allows the user to send a silent duress report while disarming if the system is being monitored by a central station EXCLUDE ZONES EXCLUDE 4 be used wh disarmed EXCLUDE CODE E can be used any time E can only en the panel is Press If the Arming Shortcut is enabled or press User Cope or press User Cope If Code Only Arming has been enabled for that user code Press User Cope Press If the Home MODE SHortcut is enabled or press User Code Press both C Panic keys together Press 5 6 8 on 9 User Cope Add one these digits in front of a user code when disarming This sequence will disarm the panel a
15. GRAMMED TO SOUND THE INTERNAL SIREN RESET OUTPUT THIS OPTION IS OFF BY DEFAULT NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL EES OPERATION Keypad MEDICAL alarm by KEYPAD Press 2 Sends a Medical Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station The Medical Alarm does not sound the sirens Keypad FIRE alarm by KEYPAD Press 3 Sounds the siren using the Fire Alarm sound If Keypad Fire Alarm has been enabled by your installer And sends a Fire Alarm report by dialler If this option has been enabled by your installer and the system is monitored by a central station 14 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPERATION How to EXCLUDE zones by KEYPAD Press If the EXCLUDE SHORTCUT is enabled or press Give User Cone E The Exclude light will turn on then press Zone No Zone No Enter the zone number s to be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed If there is a problem with a detection device and the zone cannot be sealed when arming the panel then that zone can be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously
16. Panel Battery is low or A Radio Device has sent a low battery signal or Telephone Line Fail has been detected dy df Jy a An AutoTime action is due to begin Constant SLOW beeps ai A A S An AutoTime action will begin in one minute Constant FAST beeps DISPLAY TEST To display all the keypad icons press and hold the button for at least 2 seconds All the icons will be on while the button is held down Display Test can be activated at any time either in operating mode or any program mode 6 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL KEYPAD INDICATORS KEYPAD DISPLAY INDICATORS IN OPERATING MODE KEYPAD ICON ZONES gt 7 1 8 or 1 16 Zone is sealed Zone is unsealed Zone is in alarm OK READY TO ARM Zone s are unsealed or Power fault or Panel is armed or phone line fault Ready to Arm Panel is disarmed Panel is armed a ARMED or Area 1 is disarmed if or Area 1 is armed if using Areas using Areas Area 2 is disarmed Area 2 is armed if using A ARMED Areas TY HOME Home Mode is Panel is armed in Home Day Mode enabled see disarmed Mode page 20 S Normal Memory mode selected New alarm s in memory MEMORY Normal Receiving a radio signal A Radio Key or other If radio fitted radio device has low battery Normal Internal Tamper Double Flash with long pause TAMPER External Tamper Steady flash Gt Normal Zone s a
17. Re Re ee ee 30 Installation Record ee ee Re Re 31 OPERATION SUMMARY ee eee eee ee ee ee 32 WHAT S NEW IN D8X D16X DELUXE V8 e New PCB layout e Now with 8 AUX outputs 1 4 on relay board or 1 8 on output expander s e Added modem chip for programming via NessComms use any modem in 300baud mode e Voice alarms and voice prompts using a preset voice message library e Real time clock onboard e New connector for the Serial port e New connector for the Listen in header e Required power supply is now 15VDC for efficiency Do not use 17VAC e Tamper Prog link moved to corner of pcb for better accessibility e Many new program options to cater for expanded AUX outputs ALL D8X D16X FEATURES e 8or 16 alarm zones e Supports up to 3 keypads Navigator Saturn or LCD e 56 user codes can be programmed to operate by keypad PIN radio key or access card e Optional Ness Radio Interface for fully integrated wireless security e Programmable Two Area partitioning can split the panel into two independent areas plus a common area e Real Time Clock with AutoTime features auto arm disarm auto aux outputs time based user control e 3 Door Access Controller onboard with support for Weigand prox or fingerprint readers e Control via internet using Ness iComms aComms iOS and Android apps and optional ethernet adapter e Voice alarm reports amp Voice prompts for remote telephone operation e Home Mode allows partial arming eg perimeter s
18. TO ENTER PROGRAM MODE press P Master Cove EE The factory default Master Code is 123 TO EXIT PROGRAM MODE press P E The panel will automatically exit Program Mode if the keypad is inactive for 4 minutes USER CODES The panel has 56 user codes which can be operated by keypad code 3 6 digit PIN by optional radio key or by optional access cards To add change or delete a keypad code follow the steps on page 22 The factory default Master Code is 123 You should re program this code with a new code of your own choice TIMERS You can also re program the Entry Delay Time and Exit Delay Time if you need more or less time to exit and enter the premises REAL TIME CLOCK Some features such as AutoTime rely on the onboard Real Time Clock Set the current date and time to ensure events take place as expected You will need to adjust the Hours setting when Daylight Savings starts and ends TELEPHONE NUMBER If your panel is programmed for Audible Monitoring the panel s dialler will make alarm calls to the Primary and Secondary telephone numbers programmed by your installer If a Follow Me Telephone Number is programmed the Primary and Secondary telephone numbers will be ignored All Audible Alarm calls will be sent to the Follow Me telephone Number This is handy if you for example stay at a relative s house overnight and you want the panel to call you there in the event
19. ccess Cards as required Ask your installer NOTES di A User codes must NOT start with zero The panel will allow codes beginning with zero to be programmed but they will not operate the panel This is an alternative method for disabling user codes 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected 3 When re programming a Keypad Code the old code does not need to be deleted first The new code will overwrite the old code 22 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL PROGRAMMING Programming TIMERS STEP KEYSTROKES DESCRIPTION COMMENT 1 P MasteR Cope HE Enters User Program Mode The Program light will turn on 2 Enter the option number for The existing time if any will Vo E Entry Delay Time 1 be displayed by the keypad one digit at a time or PROE Or enter the option number for Entry Delay Time 2 or PARE Or enter the option number for Exit Delay Time 3 New Time E Enter the new time in seconds The new time will be dis Example enter 25 seconds as played by the keypad one 25 E digit at a time 4 P ae To exit User Program Mode ig Program light will turn Factory default timer settings are listed on page 21 Programming the FOLLOW ME TELEPHONE NUMBER STEP KEYSTROKES DESCRIPTION COMMENT 1 P Master Cope HE Ente
20. e alarm is activated requiring the correct code E to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA PARTITIONING Area Partitioning allows the zones to be split into two partitions Area1 and Area2 The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Area1 and Area2 are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Area1 or Area2 Disarms AREA OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the Armed state This means that Day 24hr and Home zones are independent of the area operations Note Area partitioning is in addition to Home Mode Any zone may be allocated to any area 8 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPTIONS KEYPAD OPTIONS NESS KPX
21. ecurity overnight e Day Mode feature allows daytime monitoring of fire doors coolrooms etc e Temporary Day Zone feature allows easy enabling disabling of Day Mode e Keypad Panic and Duress feature e Two button arming feature e Fire Alarm feature with different siren tones e Highly flexible zone to output mapping e Onboard Vibration Sensor Analyser with programmable sensitivity Use with Nessensor vibration sensors e Multiple programmable EOL resistor values from Ok to 22k 2k2 resistors supplied e Siren chirp and strobe flash on arming with radio key e Quiet chirps option on arm disarm by radio key e True Dynamic Battery Test tests the battery under load every hour and when a keypad code is entered e 8 programmable auxiliary outputs e Enhanced serial data input output via RS232 e Automatic reset fuses e Programmable Reset Output lockout e 30 event memory from KPX and Saturn keypads 80 event memory via Navigator keypad or NessComms e Standard defaults to suit most applications e Easy programming by keypad or NessComms software e New modem chip allows common modems to be used for upload download in 300baud mode All programming data is permanently stored in a non volatile memory e All inputs and outputs are heavily protected against lightning and high voltage supply transients e High efficiency DC power supply e Optional output expander DIALLER e Full remote upload download by PC and modem us
22. g Ness DVRs are available in 4 6 9 and 16 channel models to suit all applications and all budgets even mobile models for use in vehicles such as buses and trucks Most DVR models are Internet Ready for instant connection to a LAN and broadband internet connection for remote viewing 28 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPTIONAL RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door Ness Radio Keys provide the benefits of separate ON OFF and PANIC buttons as well as optional control of auxiliary outputs all in a slim waterproof remote control Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel RK4 Radio Key RADIO KEYS Fully waterproof ultra slim 3 1 or 4 button Radio Keys for remote control of the control panel With separate buttons for ON Arm OFF Disarm PANIC and AUX functions RK4 only Including long life lithium battery RADIO KEY PENDANT ry Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal RK1 Radio for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for med
23. hanical photocopying recording or otherwise without the prior written permission of Ness Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2015 Ness Corporation Pty Ltd ABN 28 069 984 372 CONTENTS UM EE 4 INthOGUCTION iiss fet he Dated a Alene Abed 5 Key Dad seis EE EN 6 Visual ndicatOrS Es hii eternal 7 OPERATION EE ER IE 8 9 AMING RR EE ededeedestapadeiigescipvaeectpuecets 10 DIsaFMING EA SE EE Ge Re GE EN otters 11 Home Monitor Mode sesse see ee ee ee 12 Keypad PaniG ss sii iia eles 13 Keypad DureSS saiisine iiiaae 13 Keypad Fire Alarm ees see ee ee ee ee Re 14 Keypad Medical Alarm scere 14 Excluding ZONOS ie LEER NEER SE aee Be dee Fee 15 View Memory EE N 16 Temporary Day ZONES ese ee ee ee Re ee 17 AutoTime Features ees ee Re ee ee Re ee 18 AutoTime Operation ee ke ke ke ee Re ee 19 PROGRAMMING ririn otin n ee ee Re Re ke 20 Programming Options Table ees 21 User Code programming ee 22 Entry Exit Timer programming iese esse esse ee ees 23 Telephone Number programmiNg esse sesse 23 Real Time Clock programming 24 Monitoring Central station Audible 06 25 Remote operation by telephone ee 26 27 Ness ACCESSOTSICS ccccccccecceeeeeeceeeeeeeseeeeeeteeeeeees 28 29 Troubleshooting iese ee ee ee
24. ical alarm purposes Includes long life lithium battery Key Pendant RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery Top RR2 Mini Radio Reed Switch Bottom RR3 Micro Radio Reed Switch WIRELESS PRODUCTS NESS RADIO KEYPAD A unique fully portable radio keypad The Ness Radio Keypad provides totally wireless Arming Disarming of the control panel Also operates Home Mode and provides a Panic alarm The Ness Radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires G PET AWARE JI Pd AUSTRALIA a LUX Radio PIR RADIO MOTION DETECTORS Ness LUX Radio PIR a unique wireless motion detector with a white LED night light With all the features and benefits of Ness premium radio detectors LUX features 15m x 15m detection coverage look down creep zone high RF immunity white light immunity adjustable range adjustable pulse count and extremely long battery life The Ness LUX PET Pet Aware model detects humans but is immune to household pets Allows you to protect your home with your pets inside RADIO SMOKE DETECTOR F The Ness Radio Smoke Detector s provides a fully wireless smoke l eds detection option which can trigger the panel s siren s and dialler if required or as programmed by your installer The Ness Radio Smoke Detector uses Photo elect
25. ing Auto Re Arm is designed to re arm the panel if you don t enter the premises after disarming ET NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL INSTALLATION RECORD D S De 16 DIALER SECURITY ALARM PANEL NESS D8 ALARM CONTROL PANEL NESS D16 ALARM CONTROL PANEL TIMERS User programming options P26E ENTRY DELAY TIME 1 P27E ENTRY DELAY TIME 2 P28E EXIT DELAY TIME P29E SIREN RESET TIME DEVICE TYPE DIALER SECURITY ALARM PANEL DATE PURCHASED DATE INSTALLED PIR Reed switch etc DESCRIPTION Entrance bedroom etc INSTALLATION COMPANY TELEPHONE MONITORING COMPANY TELEPHONE ZONE ASSIGNMENT Installer programming options Seconds Seconds Seconds Minutes P41E ENTRY DELAY 1 P43E ENTRY DELAY 2 P42E HANDOVER P40E INSTANT P45E AREA 1 P46E AREA 2 P54E RESET OUTPUT P51E MONITOR P52E 24 HOUR P55E STROBE OUTPUT P56E SONALERT OUTPUT P57E SIREN OUTPUT P74E Report dialler D8 amp D16 oinioja ajwjn Extra Options Assigned Extra Options Assigned Extra Options Assigned USER OPTION No E 9 Radio Code OPTION No E 9 Radio Code OPTION No E g Radio Code CODE Arm Only etc Arm Only etc Arm Only etc 1 Meester P2
26. ing NessComms software e View system status and arm disarm using NessComms e Remote control of outputs via telephone with voice prompts e Contact ID Format Two 14 digit phone numbers plus one follow me number e Voice alarm reporting feature e Phone line monitoring activates output e Dialler Listen in option for installers e Auto Test calls e Hex programmable client codes as required by some central stations al NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL The Ness D8x and D16x microcomputer based 8 or 16 zone control panel is the heart of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be wired to the panel or you can use optional wireless detectors Passive Infra Red motion detectors PIRs are used to detect motion of people or animals Pet Aware motion detectors can ignore pets and still detect people Reed Switches are fitted to windows and doors to detect opening Vibration sensors such as the Nessensor can be used to detect glass breakage or forcing of windows or doors Normally a zone is considered Sealed Activation of a detection device will cause the zone to be Unsealed and may cause an alarm Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setti
27. l by KEYPAD Enter the premises through a Delay Zone Press User Cope GE The ARMED light will turn off When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to disarm the panel If the panel is not disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may disarm your system from within your premises or from outside your entrance door There is also the option to Chirp the outside siren three times and briefly flash the strobe light to indicate that you have disarmed your system If you make a mistake when entering your keypad code then you must press E or Enter and start again Five incorrect entries will cause an alarm The panel can be reset and the siren s silenced by disarming the panel If you arrive at your premises and find the strobe light flashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode by RADIO KEY Press the OFF button once The strobe light will flash briefly If required your installer can program the external siren to chirp 3 times when disarming by ACCESS CARD or FOB Bs Present a Card or Fob once if the installer has enabled disarming by access card ARM ONLY CODES User codes can optionally be progra
28. mmed to be Arm Only codes An Arm Only code can Arm the system but it cannot Disarm See page 22 for User Codes programming However if an Arm Only code is assigned to a radio key the radio key OFF button will arm and disarm AUTO RE ARM Your panel may optionally be programmed for Auto Re Arm to help prevent accidental disarming Auto Re Arm checks that you have entered the premises after disarming If all zones remain sealed for a period as set by the entry delay time then the panel will re arm This is most useful when used with radio keys where the OFF button might be accidentally pressed after you have armed and are leaving the premises If Entry Beeps are enabled 2 In the event of an alarm the strobe light will flash for 72 hours or until the panel is reset NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 11 OPERATION to arm HOME Mode by KEYPAD Press If the Home Monitor SHORTCuT is enabled by RADIO KEY Home Monitor arming by radio key must be enabled by your installer or press User Cove E Home mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones will be active in Home mode If an alarm occurs while in Home mode entering User Code will silence the alarm This will also Disarm the panel so remember to re arm Home mode
29. nd send a Duress report by dialler to the central station REPORT KEypAD Duress must be enabled Press E lf the ExcLUDE SHORTCUT is enabled then Zone No Zone No Enter the zone number s to be excluded then press to exit Exclude mode The Exclude light flashes constantly while zones are excluded Excluded zones are automatically Included next time the panel is disarmed If a user code is assigned to a radio key and has Extra Option 4E enabled Cope ONLY ARMING then pressing OFF toggles the panel arm disarm state
30. ng A zone with this assignment is called a 24 hour zone Some detection devices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a Day zone Before leaving the premises you must Arm turn on the panel After arming the panel will ignore detectors during the Exit Delay Time to allow you to exit without triggering an alarm The system can be armed and disarmed using the keypad supplied or by optional Radio Keys or Access Cards or Fobs When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm unless you disarm the panel during this allowed time INTRODUCTION When an alarm occurs it can be reset with a User Code or by optional Radio Key or Access Card Fob otherwise it will reset at the end of Alarm Reset Time Resetting an alarm stops the sirens and strobe light If an alarm is not reset the sirens will stop after the programmed time default is 5 minutes and the strobe light will stop after 72 hours Home Mode also called Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is used Radio Keys can also Arm and Disarm Areas The control panel housing and the covers ove
31. outputs D8x D16x V7 8 and later REQUIREMENTS D8x D16x V5 6 or later V7 8 or later to operate panel outputs Optional 101 244 Ethernet adapter 450 185 RS232 cable Order code K 6002 iPhone iPad Smartphone not included iComms is a third party product which is endorsed by Ness without tech support Emergency alarms must be enabled in the control panel to be available in iComms Note Radio Keys and Access cards and readers are optional and are not supplied with any Ness control panel as standard Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel RK4P requires an optional access control reader to be installed NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 9 OPERATION TO ARM the panel by KEYPAD Press GE If the ARMING SHoRTCuT is enabled or press User Cone E or press User Cope If Cope OnLy ArminG has been enabled by your installer by RADIO KEY Press the ON button once The strobe light will flash briefly If programmed the external siren will chirp once If Home Arming by Radio Key is enabled the chirp will be delayed by 5 seconds by ACCESS CARD or FOB Present a Card or Fob twice Or present a Card or Fob once press button Depending on which option has been enabled The Arme light will turn on by your installer Leave the premises within the Exit Delay Time 3 beeps will sound a
32. presence of in band radio signals high power transmissions or interference caused by electrical appliances such as Mains Inverters Wireless Routers Cordless Phones Computers TVs and other electronic devices may reduce radio range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices 2 Unauthorised tampering physical damage electrical interruptions such as mains failure electrical spikes or lightning 3 Solar power inverters are a known source of electrical interference Please ensure that this product and all associated cabling is installed at least 3 metres away from a solar power inverter and its cabling WARNING Installation and maintenance to be performed only by qualified service personnel CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries in accordance with local regulations ADSL NOTICE ADSL broadband data can interfere with the operation of your alarm dialler It is recommended that a quality ADSL filter be installed as per the filter manufacturer s guidelines in premises with an alarm dialler installed COPYRIGHT NOTICE All rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mec
33. r external sirens are protected by tamper switches to detect someone attempting to disable the security system Activation of these switches will cause an instant tamper alarm If there is a problem with a detector you can Exclude the associated zone so that it is totally ign ored and cannot generate an alarm Including the zone will enable it to generate an alarm again The control panel is fitted with a rechargeable backup battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery Test All alarms are stored in memory and can be viewed at any time in Memory Mode 1 Keypad codes programmed as Arm Onvy will not reset the panel 2 Access Cards Fobs can reset the panel if the Disarm By Access Carp option has been enabled by your installer NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 5 KEYPAD The instructions in this manual relate to Ness KPX and Saturn keypads The KPX keypad is used in examples throughout this manual Saturn keypad operation is identical Refer to the Ness Navigator user s manual for operating instructions specific to the Navigator Touch Screen keypad Pet OTC TO TC KEYPAD BEEPS BEEPS MEANING d 1 BEEP Any key press deed 3 BEEPS Valid Command e 1 LONG BEEP Error d d 10 BEEPS Mains Power is off or
34. re Excluded EXCLUDE Normal The backup battery LOW is low BATTERY Normal Mains power is off MAINS OFF Normal User Program Mode Installer Program Mode PROG Normal Dialler is on line Phone line fault or failure to communicate See page 16 for keypad indicators in Memory Mode NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL eal OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the keypad You may also have optional Radio Keys or Access Control equipment installed OPERATING RULES Generally the panel will be Disarmed Armed and Home modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any codes press the Enter or E button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt th
35. ric smoke detection technology On board sounder and test button for the sounder and radio transmitter A single battery powers the smoke detector and the transmitter Includes 9V lithium battery NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL TROUBLESHOOTING SYMPTOM When arming a zone light is on or the keypad gives a long beep POSSIBLE CAUSE One or more detection device a PIR or reed switch may be unsealed REMEDY Find the cause of movement or close the door or window e 10 beeps from keypad e MAINS light is flashing e BATTERY light is flashing The mains power may be off or the panel s backup battery may be low or a Radio Device battery may be low Make sure the plug pack is plugged in and the power point is turned on The backup battery may need replac ing call your installer 1 long beep from the keypad Invalid keypad entry Press the E button and try again 2 second siren at the end of Exit Delay time A zone was unsealed at the end of exit delay time Disarm the panel and check all zones The strobe light is flashing There has been an alarm within the last 72 hours Reset the alarm by disarming the panel and check the Alarm Memory Siren sounds while the panel is disarmed A 24 hour zone has been alarmed Siren Tamper Box Tamper Panic Button Reset the alarm by disarming the panel and call your installer EXCLUDE light is
36. rs User Program Mode The Program light will turn on 2 Enter the option number for Fol The existing telephone OW low Me Telephone Number number if any will be dis played by the keypad one digit at a time 3 New TELEPHONE Numeer HE Enter the new telephone The new telephone number number if any will be displayed by the keypad one digit at a time 4 To exit User Program Mode The Program light will turn O 6 us The Follow Me telephone number is only used in Audible Dialling mode If the Follow Me number is programmed then the primary amp secondary numbers are ignored Ask your installer for further information NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL a PROGRAMMING Programming REAL TIME CLOCK STEP KEYSTROKES DESCRIPTION COMMENT 1 E Master Cove HE Enters User Program Mode The Program light will turn on 2 Enter the option number for The existing value if any g OUD one of the real Time Clock will be displayed by the P340E MINUTES Enter a value options keypad one digit at a time between 00 and 59 P341E HOURS Enter a value between 00 and 23 P342E DAY OF THE MONTH Enter a value between 01 and 31 Ensure that the setting does not exceed the days in the current month The panel does not cross check this setting P343E MONTH Enter a value between 01 and 12 P344E YEAR Enter a value between 00 and 63 2000 2063 P345E DAY OF THE WEEK
37. s are detailed and interactive with spoken word messages clearly stating the alarm condition being reported The user can then acknowledge the alarm and hang up or enter a remote control menu which gives options to arm and disarm the system control auxiliary outputs and even exclude zones all over the phone ALARM MESSAGE TRANSMISSION Alarm reports are sent to the Primary P70E and Secondary P71E telephone numbers or only to the Follow Me phone number POOE if programmed ALARM MESSAGE FORMAT The alarm message starts with the introduction d This is a security system message To start the report press 1 The recipient must press 1 on their phone If not the message repeats d System Name security system reports the following System Name is programmed by option P198E d Alarm or Message See the Voice Messages table d Wait to hear the report again or to continue press 1 Press 1 on your phone More alarm reports if any are heard Once all alarms have been acknowledged d End of messages To control the security system press 2 then after the tone press 2 again To acknowledge and end press STAR then press HASH and then hang up the phone Press STAR then HASH to hang up Press 2 then 2 to continue to the telephone remote control menu NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 25 REMOTE OPERATION TO CONNECT TO THE PANEL BY TELEPHONE METHOD 1 The connection is initiated by the
38. s flashing after the memory is viewed as shown above and the MEMORY light is automatically cleared next time the panel is Armed KEYPAD DISPLAY INDICATORS IN MEMORY MODE KEYPAD ICON Zone numbers 1 8 or 1 16 Zone alarm MEMORY EVENT no icons displayed Panel Disarmed ARMED Panel Armed or Area 1 Armed ARM2 Area 2 Armed MAINS Mains power failure BATTERY Low Battery TAMPER 1 Internal Tamper alarm TAMPER 2 External Tamper alarm EXCLUDE 1 Panic alarm EXCLUDE 2 Medical alarm EXCLUDE 3 Fire alarm LINE Telephone line fail RADIO EXCLUDE RADIO BATTERY ZONE Radio Key Panic alarm Radio Device battery low Device number is indicated by zone lights RADIO BATTERY ARM Radio Key battery low Radio Key number is NOT indicated RADIO TAMPER ZONE Radio Device tamper alarm Device number is indicated by zone lights RADIO HOME ZONE HOME ZONE Radio Supervision alarm Device number is indicated by zone lights Wired Zone Supervision alarm Zone number is indicated by zone lights mm NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL The Ness D8x and D16x have a Temporary Day Zone feature which allows easy and flexible Day Zone selection and operation Temporary Day Zones operate in addition to Permanent Day Zones which are usually setup by the installer While remaining in normal operating mode the user can add and remove Temporary Day
39. ss 4 To hang up press STAR then PRESS HASH The user presses 1 to arm or disarm the system and the voice prompt continues d To arm Press 1 To disarm Press 2 To return Press STAR The user presses 1 to arm and the voice prompt continues with either of these messages 26 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL REMOTE OPERATION EITHER assuming Area 1 was disarmed and that Area 2 is not remote armed Q Area 1 armed Area 2 disarmed To arm or disarm the security system press 1 To control OUTPUTS press 2 To exclude or include a zone press 3 To listen to reports press 4 To hang up press STAR then press HASH OR assuming Area 1 was already armed d Invalid entry To arm or disarm the security system press 1 To control OUTPUTS press 2 To exclude or include a zone press 3 To listen to reports press 4 To hang up press STAR then press HASH The user presses 2 to control outputs and the voice prompt continues with the message d Double press the selected auxiliary output 1 to 8 Then press STAR to activate or HASH to turn off the selected output Press STAR to return The user presses 33 STAR and the voice prompt continues Q Auxiliary 3 ON The user presses 33 HASH and the voice prompt continues Auxiliary 3 OFF The user presses 32 HASH Note that this is an incorrect sequence and the voice prompt continues d To arm or disarm the security system press 1
40. t the end of Exit Delay Time The control panel must be armed in order to detect intruders Before arming all zones should be Sealed by making sure there is no movement in rooms protected by motion detectors Doors or windows protected by reed switches should be closed The panel cannot be armed if in Program Home Monitor Memory or Exclude modes or if it is in alarm User codes that are programmed to be Arm OnLy codes can arm the panel either the disarmed state or from Home Mode A keypad is supplied with the panel Operation by Radio keys and access cards is optional d Jef 10 beeps when you arm means Mains Power is turned off or the backup battery is low d J L One long beep when you arm could mean the panel is already armed or the keypad code is wrong if not using Shortcut Arming SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds to indicate that those zones have been automatically excluded You should disarm the panel check the premises and then arm again Continual warnings could mean there is a problem with a detection device that zone may have to be manually excluded If a zone is Unsealed at the end of exit time and the auto exclude option is disabled the siren will sound for the duration of siren time default is 5 minutes 10 NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL OPERATION to DISARM the pane
41. to send a PANIC report by dialler if your system is monitored by a Central Station by RADIO KEY Press and hold the PANIC button for at least 4 sec NOTE Your panel may be programmed for DOUBLE PRESS RADIO PANIC To operate press and hold the Panic button until the transmit LED turns on Release the Panic button and immediately press and hold again until the transmit LED turns on a second time This requirement meets regulations in some states of Australia PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button Keypad DURESS alarm by KEYPAD Press 5 6 8 on 9 User Cove Add one these digits in front of a user code when disarming This sequence will disarm the panel and send a Duress report by dialler if the system is monitored by a central station The DURESS alarm can be used to send a silent alarm to the central station that you are being forced to disarm the panel against your will That is you are disarming under duress To disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming THE KEYPAD DURESS IS NORMALLY NOT ENABLED TO ENABLE THIS FUNCTION CONSULT YOUR INSTALLER DURESS ALARMS CAN ONLY USED BY SYSTEMS WHICH ARE MONITORED BY A CENTRAL STATION THE DURESS ALARM CAN BE PRO
42. while the panel is Disarmed and also when Armed Zones can be excluded while the panel is either Disarmed or Armed See notes below NOTES Zone Exclude is not permanent Excluded zones are automatically included next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the Zone No E sequence to turn OFF the zone lights to be Included EXCLUDE E works only when the panel is Disarmed EXCLUDE User Code E works in any state EXCLUDE User Code E can only exclude the zones in the Area assigned to that code NESS D8X D16X DELUXE CONTROL PANEL USER S MANUAL 15 OPERATION Viewing the EVENT MEMORY by KEYPAD Press E If the View MEMORY SHORTCUT is enabled or press User Cone GE The Memory light will turn on Press The most recent event will be displayed Press The next most recent event will be displayed Press and so on up to 30 events Press E to exit Memory Mode The panel stores a comprehensive event memory including Arming Disarming Low Battery Mains Fail and Alarm events The memory is constantly updated and the last 30 events are always available for viewing This memory display can only be selected while the panel is in the Disarmed state TO CLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stop
Download Pdf Manuals
Related Search
Related Contents
metalsenser-ol [更新済み].ai NordicTrack NTTL10612 Home Gym User Manual タイヤ管理の助っ人参上!! 新発売 6. Utilisation de technologies innovantes Toshiba Satellite S855D-S5256 User`s manual "VENTS VP" ( PDF 1,64Mb ) Descargar PDF... - Mantenimiento cubiertas Ecuador Progress Lighting P5015-111 Installation Guide Copyright © All rights reserved.