1. 1 Product Introduction 1 1 Summary This device is a digital monitoring and recording product specially designed for the security field It adopts standalone processor and standalone Linux operating system The device combines with the latest technologies in the IT field such as video and audio compression decompression large capacity HDD record TCP IP network etc The code is embedded in the FLASH chip which makes the system running more steadily This device has both features of digital video and audio recording DVR and digital video and audio server DVS It can not only work locally and independently but also compose of a powerful security monitoring net with networking With the use of professional network video surveillance platform network software it can fully reflect its strong networking and remote monitoring capability It can be used for the security protection in the fields of banking telecommunications electronic power justice traffic residential factory warehouse water conservancy facilities and other areas and departments 1 2 Main Functions gt Real time Monitoring It is with analog video output port VGA port and HDMI port It can realize the monitoring function through the monitor or display It supports simultaneous TV VGA and HDMI output gt Storage Function It adopts special format to save data which cannot be tampered with and will be secured gt Compression Method It supports multi chann
2. Advance interface click track Setting button to pop up a dialog box as below Track 00m ce vA 3 r a Recor a m gt Fac s lart Record he marli Track Speed 5 t Pic 2 40 Track setting User can control the dome rotates up up left down right down left left down right and up right and stop rotating adjust the rotate speed and the value of zoom focus and iris of the dome click Start Record button to record the move track of PTZ and click this button again can stop record click Start track button to play recorded track and click this button again can stop play The user can drag the slider to adjust the rate of P T Z movement Click icon to hide the tool bar right key can remerge it click icon to exit the current interface In the Advance interface click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 27 2 4 9 Advance configuration Advanced settings include three sub menu factory settings andimport export and exit 1 Factory settings all settings back to factory settings 2 Import Export Users can export data files to be backed up onremovable storage devices you can also import the specified data file from a removable storage device to a DVR 3 Exit exit current interface Advanced Y System Reset To imporUExport wn Maintain y Pic 2 41 Advance configuration Return
3. Click Default button to resort default setting Click Apply button to save the setting click Exit button to exit current interface 2 4 5 3 Video loss Pic 2 24 Video loss 20 A Click Alarm handling button turn to window as below Alarm Handling c Alarm Buzzer Show Full S ee To Alarm Out Email Pic 2 25 Video loss alarm handling The setup steps of video loss trigger are familiar with alarm handling User can also setup all channels with same parameters click Apply button to save the setting click Exit button to exit current interface Click Default button to resort default setting Disconnected from the network when the network connection is disconnected the system will automatically sent E mail to the user specified mailbox about the network disconnected 2 4 5 4 Alarm out Alarm out includes two sub menus alarm out and buzzer 1 gt Alarm out ALARM OUT q A RO Aterm Ow Schedule CH Relay Name Delayis 1 Alarmout 1 Default Pic 2 26 Alarm out In this interface set relay alarm out name select hold time which means the interval time between the two adjacent alarms User can setup all channels with same parameters Tick off All to do relevant setup click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 gt Buzzer At buzzer interface tic
4. Equipment start POWER indicator light is red 2 1 2 Power off User can power off the device by using remote controller keyboard and mouse 2 1 3 By remote controller Press Power button the Shut down window will appear click OK the unit will power off after a while 2 1 4 Disconnect the power by keyboard and mouse Step1 enter into Menu then select System Shut Down icon the Shut down window will appear Step2 click OK the unit will power off after a while Step3 disconnect the power 2 2 Login Equipment start POWER indicator light bright initial password is blank After equipment start press MENU key on panel or press right key on mouse trun to login interface as below User Login User Hamme admin Password Login Pic2 1 User login After Input matching user name and password you can enter system to setup and operation Live preview interface o A o A gt ten B a A i Motion Timing an tion Recording il detectio recording i n state state gt Live playback Click Playbutton to playback the record Enter fast record playback as lelow picture User can do concrete operation by click the buttons on screen 2 3 Main menu setup guide Menu bar Click right mouse or press ESC button on the front panel the control bar will display on the bottom of the screen refer to pic2 2 switch Colour prz playback N Mm eats den gt Screen mode E zoom volume
5. and highest Support CBR and VBR Select range 16kb 32kb 64kb 128kb Macbitale 256kb 512kb 640kb 768kb 1024kb 1536kb 2048kb 3072kb 15 A As Stamp User can overlap the channel name and time stamp on video Alarm RectTime Stamp Loop Record limeStamp osition Default Apply Pic 2 13 Character overlay Tick off camera name time stamp click Setting button and then user can use cursor to drag the camera name and time stamp in random positions Please refer to below Figures User can also setup all channels with same parameters Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 3 4 Recycle record Tick off recycle record to enable the recycle record function It will cover the earlier recorded files and keep recoding when HDD is full if disenabled it will stop recording when HDD is full Note general the image quality frame rate and resolution parameters setting higher the more take up disk space Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 4 Schedule configuration Schedule configuration includes two sub menus schedule motion and sensor 2 4 4 1 Schedule The volume means the seven days of a week from Monday to Sunday the row means 24 hours of a day Click the grid to do relevant setup Blue mea
6. button will save the above settings Click the Exit button to exit the current interface 2 4 2 Live configuration Click Live configuration enter window as pic2 8 Live configuration includes two submenus live and mask 2 4 2 1 Live configuration Show Hame Y Display recording status Setup Default Apply Exit Pic 2 8 Live configuration Note Click Camera Name to see a soft keyboard User can choose different character format to input 12 A es Tick off camera name and click Setup button to display a window as below Pic 2 9 Live color adjustment In this interface user can adjust brightness hue saturation and contrast in live click Default button to resort default setting click OK button to save the setting user can setup all channels with same parameters please tick off all and then do relevant setup 2 4 2 2 Mask Private mask User can setup private mask area on the live image picture Default Apply Pic 2 10Mask Setup mask area click Setting button enter into live image to press left mouse and drag mouse to set mask area refer to below picture Click Apply button to save the setting Delete mask area select a certain mask area click left mouse to delete that mask area Click Apply button to save the setting A Live image mask area 13 A 2 4 3 Record configuration Click Record configuration enter window as pic2 11 Record configuratio
7. devices Network information Enter menu gt view information gt Network configuration in the interface Users can view the relevant parameters of the network information 30 SS 2 8 Disk management Enter menu gt Disk management In the interface the user can view disk storage state also can choose to formatting the hard disk Please format the hard disk before record Specific operation as below Step1 enter into disk management interface The system will pop up the Disk Management window Step2 select a hard disk and click Format button to star format set the property of the disk then click Apply button to save the setting Note all recorded files in the hard disk will be lost after formatted 31 A 2 9 Upgrade Once have the new version the user can choose to upgrade the panel and the mianboard can get upgraded software from the buyers to upgrade the system Upgrade step user needs to copy the upgrade software which get from vendor into the USB storage device and then connect to the USB port Enter Menu Upgrade refresh list the upgrade software name is displayed in the upgrade list box select that software and click Upgrade button to start upgrading System will automatically restart on the upgrade process Please wait for a while when the system is rebooted Please don t cut off power during upgrading This system supports the upgrade of the USB device but it must be compatible with the USB d
8. include mouse power lines and data lines 1 3 Front panel buttons description Statement the front panel interface button layout and type real product shall prevail The front panel buttons Description Buttons on Front Panel 1 IR Sensor Red Color IR receiver for the remote control 2 LED Indicators Shows status of alarm rec power link HDD 3 Playback During playback press the following 44 Increase reverse playback speed 1X 2X 4X 8X Press to start playback Hil Press to freeze playback to one frame then press again to advance frame by frame WPI Press to slow playback speed by 1 2 1 4 1 8 bb Press to increase forward playback speed 1X 2X 4X 8X 4 MENU OK Press to open close the main menu or confirm 5 Navigation Press the Navigation buttons to perform the following e In menus press to confirm selections in PTZ mode press to change the navigation buttons to control the connected PTZ camera not included e A Press to move cursor up in PTZ mode press to pan camera up e Y Press to move cursor down in PTZ mode press to pan camera down q Press to move cursor left in PTZ mode press to pan camera left p Press to move cursor right in PTZ mode press to pan camera right 6 USB Connect a USB flash drive to the top port for data backup and firmware upgrades connect a USB mouse to the bottom port O uaua 1 4 Rear panel diagram Statement pic the rear p
9. off All and then to do relevant setup Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 5 2 Motion Motion includes one sub menus motion 1 gt Motion Motion CH Enable Detay s Motion Handlin Area Setup Setup Setup Setup Setup Setup Setup Setup Pic 2 21 Motion Click start motion alarm and set alarm hold time It refers to after close motion alarm it delay to the preset setting time Click alarm Settings button show below window 19 otion Handling c Alarm OK Pic 2 22 Alarm handling Alarm configuration trigger video alarm handling linkage alarm handling and sensor alarm handling trigger settings is same Click on Area Settings button at Motion detection interface trun to the following window A Pic 2 23 Motion detection Regional Settings At area Setting interface users can drag the slider to adjust the sensitivity value 1 5 the default value is 4 1 5 sensitivity progressive increase Sensitivity influenced by the color of time day or night the users should adjust according to actual situation click icon Fale set All locales for the detection region click icon will clear setting detection region click icon save setting click button exit from current interface User can setup all channels with same parameters please tick off All and then to do relevant setup
10. H 264 NETWORK Embedded DVR User Manual 960H DVR Thank you for purchase our product Please read this user manual carefully to ensure that you can use the device correctly and safely Attentions The DVR should be installed in a well ventilated place keep suitable space from ground benefit for machine cooling Be sure not to block its air vent keep away from heat sources and high temperaturea environment 0 Please keep the level installation of this product should be avoid install at violently shaking place such as the back of car motor above high and rough luggage rake For avoid short circuit cause fire or other damage when wash the car please prevent DVR include camera and other parts touch water and wet the machine don t have waterproof The equipment consists of Precision Parts please do not try to disassemble or adjust any parts if need maintenance please contact the distributer or customer service 0 Please select the hard disk which commended by the manufacturers suit the DVR work requirement to meet a long time largeamount of data read and write requests please purchase from the formal channels to ensure the hard disk quality This product can t bear heavy weight please do not place heavy object or multi layer laminated on the product Disclaimer The Company is do the best to make the contect correct and complete during the preparation of this manual if has any errors or omissions without an
11. and stop rotating can adjust the rotation speed of the PTZ focus and aperture choose preset arrange NO Click Save button to save the settings click E icon to hide the tool bar right key can remerge it click icon to exit the current interface In the preset interface click OK button to save the setting click Exit button to exit current interface In the Advance interface click cruise Setting button a dialog box will pop up as below Pic 2 38 Advance cruise Setting 26 EE es Click Add button to add cruise line max 32 cruise line can be added select a cruise line and click Setup button to see a window as below Cruise Preset Pic 2 39 Cruise set preset pointsetting Click Add icon to set the speed and time of preset point select a preset point and click Delete A icon to delete that preset poin click Modify icon El to modify the setting of a preset point User can click those icons to adjust the position of preset point top kii upi down land bottom Click Preview button to preview the cruise line and then click OK button to save the setting Next click Exit button to exit current interface Select a preset point in the cruise line list box and click Delete button to delete that cruise line click Clear all button to clear all cruise line from the list box click OK button to save the setting click Exit button to exit current interface In the
12. anel interface button layout and type real product shall prevail below rear panel picture may be different with the actual panel Connectors on Rear Panel a a om Force HOM mo 4 1 0 alarm input 5 1 1 O output for alarm RS 485 RS 485 for connecting PTZ PU Audio output For connection audio output LINE IN For connecting Intercom equipment UN Audio Input For eee reper audio signal input po Video outpu video output for connecting TV or monitor video output for connecting TV or monitor BNC Video input For connecting digtial video signal input BNC 1 5 Remote control In device operation the enter key on remote control has the_sa left click of the mouse O Do A A A The remote control is the secondary input device a u For navigating the system s interface To use the remote control 1 STANDBY When DVR on constantly press the RED button on the top for 3 seconds the DVR will be in standby status Under standby mode press one time for immediate start 2 LOGIN LOCK If Security has been enabled in the Setup menu press to open the user password login screen 3 Number Channel buttons While in menus press buttons 0 9 to enter values during live viewing press to view channels in full screen 4 Press to switch between quad and split screen displays 5 MENU Opens the main menu 6 PTZ Press to open the PTZ control window 7 EXIT Close menu windows 8 Navigation OK e dl Move cur
13. arm type according to triggered alarm type Two option low level and high level User can setup all channels with same parameters please tick off All and then to do relevant setup Click Default button to resort default setting click apply button to save the setting click Exit button to exit current interface 2 gt Alarm handling Schedule Setup Default Apply Pic 2 18 alarm handling alarm configuration sensor Select hold time and click setting button Then a dialog box will pop up as below Alarm Handling Alarm Pic 2 19 alarm handling alarm configuration 18 A Alarm configuration in the alarm configuration interface can check the alarm way audible alarm trigger alarm and e mail alarm Trigger recording check the trigger channel at trigger video interface Click OK to save the above settings click Exit to exit the current interface channel Alarm linkage set the alarm type and linkage type at linkage alarm interface such as preset positions cruise line or track Note these three is already applicable in before PTZ configuration click OK to save above settings when the corresponding channel alarm input PTZ start a preset point cruise lines and trajectories Click Exit to exit the current interface Alarm Handling Alarm Type Null Null Null Null Pic 2 20 Alarm handling alarm linkage User can setup all channels with same parameters please tick
14. cludes two submenus serial port and advance 2 4 8 1 serial port Sertal Enable Baud Rate Protocol Y 2400 PelcoD 2400 PalcoD Y Y 2400 PeicoD Y 2400 PelcoD 2400 PeicoD R Defaun Apply Pic 2 34 Serial port Click Start base on P T Z support Protocol to set Address Baud rate and Protocol User can setup all channels with same serial port parameters please tick off All and then to do relevant setup click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface Definitions and descriptions of serial port Parameter ee The address of the PTZ device Baud rate Baud rate of the PTZ device Range form 110 300 600 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 921600 Protocol Communication protocol of the PTZ device Range from PELCOP PELCOP1 PELCOP5 PELCOD PELCOD1 HY PHILIPS SAMSUNG SHARP SONY SAMSUNG PANASMIC CONTROLI etc 2 4 8 2 Advance configuration Pic 2 35 Advance 25 SS ayla In the Advance interface after clicking preset Setting button a dialog box will pop up as below j J ng J 1 J Pic 2 36 Preset point setting In the preset set interface click Setting button to see a window as below Pic 2 37 Preset setting User can control the P T Z up up left down right down left left down right and up right
15. ed to the main menu enter the data retrieval interface 2 5 Data retrieval Search configuration includes two submenus Time Search Event Search 2 5 1 Time search Step1 enter into Search configuration gt Time Search refer to below pic Data Search May timo By type Start Time 2013 01 09 00 00 00 End Time 2013 01 09 Channels 1 13 4 15 16 17 20 21 22 23 24 25 Start Play 27 28 29 30 31 Pic 2 42 Time search 28 Step 2 Select the channel the calendar date the start time and end time Step 3 click Play lbutton Playback will start from the set time bucket click the corresponding button on the screen to start concrete operations play pause Next section Colour control Volume exit StOR FF amp rewind E zoom Hide Last section Play process Pic 2 43 Playback buttons 2 5 2 Event search Step1 enter into Search configuration gt event search refer to below pic Dala Search as By Timo By Type Start Play H l 2 Start Time i y Start Time2013 Timer 2013 07 29 578 1120 48 00 OO Timer 2013 29 1 01 1120 48 Timer 2013 29 20 y 112048 End Time 2012 Timer 2013 29 29 1120 48 Timer 2013 29 lt 29 1114 48 Timer 2013 29 lt ox 29 1448 Timer 2013 29 201 29 1114 48 Timer 2013 29 14 32 2013 07 29 11 M4 48 Vit Click to pilay id ry P ce Y Timer Y Move Y Sensor Y Manual Pic 2 44 Event search Step2 After clicking Search button the searched event information
16. el audio and video signal Each channel of audio and video signal is compressed in real time by independent hardware The sound and image keep stabilized synchronization gt Backup Function It backups through USB port such as common U disk mobile hard disk SATA Combo etc The client computer can download and backup the files on the hard disk via the internet gt Video Playback Function Each channel can realize independent and real time recording while retrieval reverse play network monitoring video search and download etc can realize simultaneously Multiple playback modes slow forward fast forward reverse play and frame by frame play When playing back the video the exact time of the event can be displayed gt Network Operation Function Through the internet you can realize remote and real time monitoring remote video search and playback and remote PTZ control gt Communication Port With RS485 port and PTZ control With standard Ethernet port realizing network remote control function gt PTZ Control Support the PTZ decorder which communicates through RS485 Can expand multiple decoding protocols facilitating the realization of PTZ and dome camera control gt Intelligent Operation Mouse operation function For the same settings on the menu you can copy and paste quickly check equipment and accessories When you receive the product please check the accessories are complete or not DVR accessories generally
17. erface network configuration network Parameter Meaning OOO FPS Range from 1 30 NTSC 1 25 PAL Support D1 CIF Quality The higher the value is the clearer the record image Six options lowest lower low medium higher and highest 22 A 2 4 6 3 Email Network Network stream Tema Other Send Address Password Receive Address Receive Address Receive Address Load default OK Default Apply Exit Pic 2 29 Email SMTP Server Port the name and port number of SMTP server Send address password sender s email address password Receive address receiver s email address Here user can add at least three mail addresses Click Test button to test the validity of the mailbox Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 6 4 Other settings Network Network Sub stream Y IONS Server no ip User Name Password Host Domain Update interval Minutes DONS regist domain failed Defaull Apply Exit Pic 2 30 Other settings Enable DDNS server user needs to input user name password and host domain name of the registered website click TEST to test the effectiveness of the relevant information click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface Note the user select a domain name is bound by
18. evice need to reboot the system after the upgrade completed to take effect Note If the upgraded software does not appeared in USB usually the USB devices are not compatible Mainboard 2 10 Logoff Enter Menu gt Logoff Click Log off icon The system will exit the current user login If saa wants to log in again click mian menu icon to enter into user name and password to re login 2 11 System shut down Click system shut down icon shut down system 32
19. k off Buzzer set buzzer alarm hold time 2 4 6 Network configuration Network configuration includes four submenus network sub stream Email and other settings 21 A As 2 4 6 1 Network Pic 2 27 Network configuration HTTP port the default value is 80 If the value changed user needs to add the port number when typing IP address in IE address blank IE set HTTP port to 82 IP address http 192 168 0 25 user needs to input that address http 192 168 0 25 82 into IE browser Server port data and image communication port NO After selecting the Obtain an IP address automatically the device will distribute IP address subnet mask and gateway IP and DNS server Enable PPPoE to directly connect the DVR to internet via ADSL and then input the user name and password click TEST button to test the effectiveness of the relevant information Click Default button to resort default setting click Apply button to save the setting Click Exit button to exit current interface 2 4 6 2 Network Sub stream Network p Network Sub stream Email Other Resolution Fps Encode Quality Max Uitrate 3 Fps CBR ALS hd 3 Fps v CBR 64Kb 3 Fps CBR 54Kb v y CBR 54K b v 54K b X Load default OK Defaull Apply Exit Pic 2 28 Network Sub strea select fps resolution quality user can also setup all channels with same parameters click Apply button to save the setting click Exit button to exit current int
20. n includes four sub menus start record bit rate Character overlay recycle record 2 4 3 1 Start Enable Stream Alarm RecTime Stamp Loop Record Enable Audio Y Y Y Y Default Apply Exit Pic 2 11 Start Tick off record channel channel audio User can setup all channels with same parameters tick off All then to do relevant setup Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface Video parameters instruction Parameter Meaning Every channel video record switch Start use the channel record audio 14 o es 2 4 3 2 Record bit rate a 2043403 19 15 34 17 Enable Stream Alarm RecTime Stamp Loop Record esolution Fos Encode Quality Max Bitrate gt 5 ps VBR rst 4096Kb v 25 Fps VBR st 6144Kb 25 Fps VBR jest 6144Kb v 75 ps VBR st 544K b Default Apply Exit Pic 2 12 Record bit rate Setup rate resolution quality encode and max bit stream User can setup all channels with same parameters tick off All then to do relevant setup Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 3 3 Record stream introduce Parameter Meaning Support 1080P 720P D1 CIF The higher the value is the clearer the Quality Recorded image is Six options lowest lower low medium higher
21. ns checked area gray means unchecked area 116 00 120 00 Sunday Monday Tuesday Wednesday Thursday Friday Saturday Apply lo Pic 2 14 Schedule Copy User can apply the schedule setting of certain channel to other or all channels Just only select channel and click Copy button 16 Click Default button to resort default setting click Apply button to save the setting click Exit button to exit current interface 2 4 4 2 Motion Schedule Timor 100 00 104 00 108 00 112 00 116 00 120 00 Default Apply Pic 2 15 Motion The setup steps of motion are familiar with schedule Note the default schedule of motion detection is full selected that is the color of schedule setting interface is blue 2 4 4 3 Sensor 100 00 104 00 108 00 112 00 116 00 120 00 Pic 2 16 Sensor The setup steps of alarm are familiar with schedule Note the default schedule of sensor is full selected that is the color of schedule setting interface is blue 2 4 5 Alarm configuration Alarm configuration includes five sub menus sensor motion video loss and alarm out H 264 DVR 17 A 2 4 5 1 Sensor Sensor includes two sub menus basic alarm 1 gt Basic SENSOR Alarm Handling Schedule rm o CH Ly Type Name High Level Sensor High Level Sensor High Level Sensor High Level High Level Default Apply Pic 2 17 Sensor Basic Enable sensor alarm and set the al
22. r and so on The definitions for every parameters display as below Device name It may display on the client end or CMS that help user to recognize the device remotely Device number Corresponding with the remote control number Video format two modes PAL and NTSC User can select the video format according to that of camera Password check Enable this option user needs to input user name and password can do corresponding operations with the relevant right in system configuration Show system time choose display time in liveor not Video output the resolution of live display interface range from VGA800 600 VGA1024 768 VGA1280 1024 HDMI 1080P Language setup the menu language English Italian Greek Russian Polish Portuguese Turkish Hungrain Spanish French German Japanese Slonakia Vietnam Simple Chinese Traditional Chinese Click the Default button the system restore the default things Click the Apply button will save the above settings click the Exit button to exit the current interface Tip to change the menu language and video output the device will restart 11 A 2 Time 8 date Basic System Date amp Time Date Format YY YY MM DD Time Format R 24H System Date 2013 o7 29 System Time 1 12 08 Default Apply Pic 2 7 Time amp date Set the date format time format time zone at the date and time interface Note Click the Default button the system restore the default settings Click the Apply
23. record Main menu Pic2 2 Menu bar Click the Mm icon near Screen mode appear channel choose frame as below Pic2 3 Channel choose user could choose 1 channels from 1 4 to show live video click to save Click function menu Will show dialogue frame as Pic 2 4 Main Menu y gt N S lllo Contig Dala Search Data Backup Information SG kk 0 Hard Disk Upgrade Logon Shut Down Pic 2 4 Mian function Click Config display syswindows as pic2 5 amp E Record Schedule Setup ane H 264 DVR Pic 2 5 Configuration management Press MENU button on the front panel or the same button on remote control also cuold display the same window 10 2 4 Configuration management Configuration Management contains nine sub menu basic configuration on site configuration video configuration recording plan alarm configuration network configuration user management PTZ configuration and advanced configuration 2 4 1 Basic configuration Click Basic configuration show window as pic2 6 The basic configuration contains two sub menu system date and time 1 system Basit System Date A Time Device Name Device ID Video Format Password Check Y Show System Time Y Video Output HDMI 1080P Language English Proviow patrol interval Show Guido Default Apply Exit Pic 2 6 System In this interface user can setup the device name device ID video format Video Output and language Screensave
24. sor in menus up F Move cursor in menus right d Move cursor in menus left e Y Move cursor in menus down e OK In menus press to confirm selections during playback and preview press to view system information 9 In menus press to adjust values 10 RECORD Press to start manual recording 11 STOP Press to stop manual recording 12 EXTRA For the future use 13 Playback controls TIP When using the remote control to enter password and camera titles select the field using the navigation buttons press ENTER and then press the number buttons e 4 Increase reverse playback speed 2X 4X 8X e F Press to start playback e bl Press to increase forward playback speed 2X 4X 8X e FH Press to slow playback speed by 1 2 1 4 1 8 HIF Press to freeze playback to one frame then press again to advance frame by frame Check whether there is fluorescent light being used in the nearby For the convenience of readers read and quick queries the following sections with a example of 4 channel digital hard disk recorders to introduce the details and pictures are base on this model other model s operation interface are the same except channel and frame rate Corresponding parameter to the same settings individual parameters can be directly and so on 2 Basic function operation 2 1 On off Switching navigation 2 1 1 Start Before start Please ensure all parts connected well Power on
25. the Domain Name Service for DVR you must first landing the website of the ISP registered user name and password and then apply for a domain name for the server online After the application is successful the user could enter the domain name to access the server in IE side 23 2 4 7 User management Enter User management as below pic Users User Name User Type MAC Address admin Administrator Ho binding guest Guest Mo binding Administrator Mo binding Pic 2 31 User management Clicking Add button a dialog box will pop up as below Oy User Name R word Password Pic 2 32 General General Input user name password select user type input the MAC address of the PC click OK button this user will be added into the user list box click Exit button to exit the current interface Authority Manual Record Playback Hard Disk File Management Two Way Audio Remote Login em Upgrade Shut Down Pic 2 33 Authority In the authority interface assign the definite operation right for that user In the user management interface click Setup button to modify user name user type and binding PC MAC address Select the user that user wants to delete in the user list box and then click Delete button to delete this user click Change password button to modify the password and then click Exit button to exit the current interface 24 SS i 2 4 8 P T Z configuration P T Z configuration in
26. will displayed in the event list box double check a certain record file to playback Step3 User can select date channel Tick off Motion Sensor or All accordingly to search 29 SS i 2 6 Backup This unit supports backup by USB device User also can make backup by IE browser via internet Step1 enter into backup configuration interface as below pic Pic 2 45 Data backup Step2 set the start amp end time select channels and click Search button to display the searched data in the data backup list box Step3 checked a data file or tick off All to select all data files click Backup button Step4 in the backup information interface user can check the relevant information of backup files storage type save file type etc click Start button to starting backup 2 7 Check information Through this option the user can check system information system journal network information System Information Enter menu gt view information gt system information in the interface user can view the equipment and version information and relevant information Log information Enter menu gt View system information gt Log information in the interface users can set the start amp end time of log you want to view select the type of log you want to view and click the search button searched the log information will be displayed in the log list box Note Users can export data files to be backed up on removable storage
27. y liability the company reserves the right to change any hardware and software mentioned inthis manual at any time and without explain beforehand Thank you for choosing our products please read this manual carefully before use Due to not according to the specified operating losses company will not assume any financial liability and legal responsibility O e CONTENT VARELA UA iio 4 SR A TSR OTE 4 AZ MaN ONC ION Si co S 4 1 3 Front panel buttons descriptiON oooocononoccnonaccnonaconancnonnnnnonananononanonnncconanoos 5 t4 Rear panel diagrames o E a ET E EEO EEA 6 To Remote COMM Ol ic iien Sie e ch ee ca ek T Z BASIC UNCION Operahan dias 8 2 1 ON OFF Switching navigati N sessie EE RREAN 8 PAA E oe A A EAE 8 2 3 Main MENUS CTU guild E ita na i A R 9 2 4 Configuration ManageMeN ccecee cece ee eee cece eeeee eset ences eeeae ena 10 241 BASICO AQUA O Md dadas 11 24 2 A EE O 12 24 3 Record coniguratioMe nanana E A 13 2 4 4 Schedule CONFIQUIATION narren NR 15 2A SAlam Configura honea a iaa 16 2 4 6 Network CONTIgUTAtiON ooooononononnnoononononnonanncnnnnonnonanonanona nono nonancnnnnono 20 24 7 User mana dementes ds loans waes 22 ZO PTZ CONQUE 24 24D AGVANCE COMMGULAUON ct 217 220 Data temeraria e 21 29 1 Time A ais 217 SN SS O Pizana ea EE seadeenceesusenuatelacuneca ee 28 2 0 BACKUP on N E E E a 29 ZII O ads 29 ZO ISK MNAE MEE 29 A A anus aes SES ERE 30 E A o nn ome 30 ZAS UA e OAR 30
Download Pdf Manuals
Related Search
Related Contents
Sea Gull Lighting 65941-962 Installation Guide 経年劣化に伴う 家電製品の事故 - 日本損害保険協会 JURAGON Pro USER MANUAL - Poultry Supplies from MelcoJet User Manual PDF XCSoar 6.8 BENUTZERHANDBUCH Researcher`s Resource Guide - MAST Laboratory, University of Manual de instrucciones Manual del sistema Equipo de Copyright © All rights reserved.