Home
JURAGON Pro USER MANUAL - Poultry Supplies from
Contents
1. 5 ounces of water in each corner of the egg tray Fig 1 which equates to 20 ounces oz total of water as shown in Fig 2 Also fill the lower inside bottom tray with 16 ounces of water Fig 3le Do not get water on eggs when adding water 1 Before installing the main top body 1 and starting incubation fill water oreferably distilled water although not required into the water tanks and of the main lower body 2 as shown in Fig 4 shown to the right Use room temperature water not warm or hot water A Always remove water from the incubator before moving it Otherwise the incubator electronics can be destroyed and void the warranty 2 Be sure the humidification heater part Fig 6 of the main body 1 is fitted down into the water tank of main body 2 when assembling rP Tinj Do not apply force or bend the humidification heater part on the upper part of the body as shown in Fig 6 It may cause failure and would void the warranty 3 After placing your hatching substrate as described above place the egg tray inside the incubator and operate it for 3 hours Then check for proper temperature and humidity and place your hatching eggs into the tray as shown and described Be sure to carefully bury your hatching eggs only leaving about 10 of the egg showing Remember to mark the top of the eggs before moving them from where they were laid and move them carefully being sure you do not shake them 4 B
2. inlet vent For inlet of air Top View Window from outside For a clear view of inside Double pane construction to reduce humidity condensation Rubber Water Cap Open to fill water for humidity control Digital Control Center See instructions for all control operation functions Locking Buttons Total of three Main Upper Body 1 two more on rear side Lower Body 2 3 Basic Components Lower Body 2 Main Upper Body 1 Power Cord 120 Volt for USA Water Cap AENT E E aes dee TES igri yamai aan ata Sa eae Clear View Window 4 How to Assemble Insert the power cord in the power receptacle on the rear of the main upper body T Main Body 2 V7 F Lock the three locking Un E i buttons One on the front and two on the rear of the incubator 5 How to Replace Fuse gt If the incubator fails to power up and you are sure that power is present perform the following FIRST UNPLUG THE POWER CORD FROM THE WALL OUTLET Remove the internal plastic cover as shown A small phillios screwdriver is required gt Once the cover is opened you will find the electronics board as shown Remove faulty fuse with screwdriver gt Replace with new fuse per image at right and specifications below DO NOT USE ANY OTHER SIZE OR RATING FUSE 250V 2 0Amp 5 20mm 6 Before Operating Your New Reptile Incubator Please Read Carefully Only Top 10 sf EJJA Exceed Room temperature s
3. may be mineral buildup on the humidification heating part It doesn t affect operation and you just need to clean it with a very soft brush when cleaning the unit Do not scrape it with a knife razor blade or any sharp object as you may damage the rubber membrane A Do not use sharp objects on the humidification heating part or it can be damaged and not covered under warranty A Am X A Do not clean the product with solvents Such as benzene paint thinner etc 16 How to Calibrate Temperature and Humidity A Remember that calibration is not a normal function that you It is also not used to set the operating temperature amp humidity conditions for incubation DO NOT PEFORM THESE CALIBRATION FUNCTIONS OR YOUR HUMIDITY AND TEMPERATURE CALIBRATION WILL BE CHANGED AND YOUR UNIT WILL NOT WORK PROPERLY Only perform this is you are a qualified repair center or know what you are doing Recalibration is not covered under warranty but can be made by any competent person with a very accurate thermometer and accurate humidity meter The unit we use at the factory is a 1500 temperature humidity meter that is very accurate A The calibration function is used to properly match the temperature and humidity inside the incubator to correct values measured inside the incubator using a very accurate thermometer and hygrometer Do not calibrate the incubator as normal thermometers and hygrometers are not more reliable than the factory incubator calibra
4. Display Temperature Abnormal Display Daily Temperature Gap Off Daily Temperature Gap On Current Humidity Display Humidification function OFF 9 SET UP Menu Functions All Reset ALL RESET DO NOT RESET The Factory uses an expensive calibrator to perform very accurate calibration f Basic information of Incubator NTO ane Software Version Indication T CAL Temperature Calibration H CAL Humidity Calibration Do Not Calibrate unless you have an expensive high accuracy thermometer Do Not Calibrate unless you have an expensive high accuracy humidity meter Select between Centigrade C and Fahrenheit F LCD Backlight management setting Always On Always Backlight On Event On 20 Sec ON with Key input Always Off Always Backlight Off Default Value Always On ON OFF Setting for Melody low water amp other alarms Default Value ON Button Sound still remains 10 Easy Function Main Menu Operation REFER TO HOW TO START INCUBATION FOR MORE INFORMATION Automatic Mode l Select ncubation the Species of Reptile 2 Sec Other Manual Mode Incubation Select the Species of Reptile Temp Setting Humid Setting Daily Temp Gap Setting Fh la How to change Settings During Incubation QUICK SET Once Temp Setting Twice Humidity Setting Three times Daily Temp Gap setting Incubation Screen ria System finish Termination on Incubation Are you sure Incubator Ini
5. JURAGON Pro USER MANUAL PX 20RD USA Pro Model Ver 2 2 09k 1 Safety Precautions Electrical hazards ACAUTION Read all details below before use SO ES Do not use damaged power Do not pull on the cord Never pull the plug out of the Do not twist pinch or Do not insert multiple cord or damaged power when and keep your hands outlet during the incubation crush the electric cord connecting plugs in outlet away from plug connectors period Risk of electric shock outlet Risk of electric shock or Risk of electric shock or Incubation operation will or fire Risk of fire or electrical fire fire stop until power is restored overload edk Cautions Merael Read all details below before use Do not operate in a Do not operate in Do not operate in moist Do not operate in Do not use other parts dusty or dirty location with direct or humid environment excessively cold or hot except those provided environment sunlight Risk of fire or Risk of fire or electric conditions smoke etc Risk of damage or Risk of damage or fire improper incubation shock Risk of improper improper incubation within the incubator results incubation results results Do not cover the ee os Install away from heat Be sure the incubator is Do not turn incubator Do not install where ae A sources Risk of damage to operated on a stable upside down Water will anyone can easily m ove ee the incubator and improper surface away from edge pour out of the incuba
6. Setting Incubation Temp Setting Humidity Setting Incubation Humidity Setting Temp Gap Time Setting Daily Temp Gap Temperature Settina ETF Temperature ch ame leon h f 85F Pas EXT Temperature setting screen SEZ Humidity Chameleon 88 fF SN Humidity setting screen U Hi Tems Chameleon he Fi SHR ees Hi Temp Cycle Gap Time Setting Screen Shiai Hi Temp Set Ch am ele on OOF f Hi Temp Cycle Gap Hour Setting Screen LHi Temp Set QUICK SET Screen STEP1 Temperature setting example The reptile incubation temp on the menu screen is memorized in the microchips User can optionally change the incubation temperatures Initial setting depends on type of reptile selected STEP2 Humidity setting example The reptile incubation Humidity on the menu screen is memorized in the microchips User can optionally change the incubation Humidity Initial setting depends on type of reptile selected STEP3 Daily Temp Gap Time Setting example Daily Temperature Gap time function simulates the warmest period during the day that would normally be found in nature for the species User can input the amount of hours to set the optimum conditions Initial setting three hours STEP4 Daily Temp Gap Temperature Setting example This sets the warmer temperature amount in degrees by the amount of hours in the abov
7. bating Other species of reptiles that are not included in the incubator oreset menu You can set the Incubation condition according to your needs Press MENU button and select Others with UP DOWN button and then press the ENTER button Set your desired temperature humidity and daily temperature gap to meet your requirements and press the ENTER button after each input gt What is Daily Temperature Gap Function This function allows for incubation conditions very similar as found in nature It creates the highest temperature time period that would be produced by the sun as in nature This function helos increase hatching rates with optimum incubation conditions 12 How to turn the Humidification Function OFF not normally used gt You can turn off the humidification function when you don t require higher humidities gt Press QUICK SET button twice and press DOWN button until OFF indicated at humidity setting Then press the ENTER button OFF will show when the humidity is under 40 13 How to Terminate End Incubation after your eggs hatch gt Press the MENU button until it says System finish Are you sure gt Select YES with the UP DOWN button and then press the ENTER button Do not turn your incubator off and then leave it closed without cleaning amp drying it out Otherwise humidity will build up on the internal circuits since the heaters are not functioning This can damage your incubator which would n
8. e step In nature it is often found that the temperature is about 1 degree F to 2 degrees F higher than the incubation temperature for the remainder of the day Desert reptiles often experience an even higher daily temperature rise Initial setting depends on type of reptile selected gt QUICK SET button This button is used to quickly change the incubation environment conditions IE temperature humidity daytime temperature gap If QUICK SET button is pressed the temperature window blinks in the incubation progressing screen When changing temperature set the temperature with up down button and then press enter button to move to next step It will be then stored and after all steps are reviewed it will return to normal operation If you do not want to change any certain step of the incubation environment press the QUICK SET button to move to the next sten gt You change to next mode by pressing the QUICK SET button 1 to 4 times You can also use it when you want to double check incubation settings while incubation is in progress gt Auto Incubation Optimum incubation conditions for the species of reptiles are memorized in the microchip With this function you can easily set up this incubator Select the species of reptile after pressing the MENU screen with the QUICK SET button and then press ENTER button for about 2 seconds to start incubation gt Other Manual Incubation Other Manual incubation is for incu
9. hould always be en bout 4F than the incubat 7 SBOOHOCOCHOGOBEO000 abou ower than the incubator a E era E operating temperature and room ar Varmiculite OO humidity should always be at least Dome ey oc 4 lower than the incubator m AUSUS Tata operating humidity Place eggs in Egg Hatching Tray Egg Hatehing Tray Side View Figure 1 Figure 2 tray last The incubation room should be between 62 F 77 F The incubator does not cool the air and the room humidity be between 35 70 Note The room temperatures provided are for incubator operation at least 4 F higher than room temperature gt For low humidity operation 60 80 Fill the HatchRite or vermiculite incubation sand purchased separately into the small incubating tray as shown above in Fig 2 No extra water is required in the bottom of the egg tray Fig 2 Be sure your HatchRite or Vermiculite is pre wet to a consistency of slight moisture BUT NOT TOO WET Use a total of about 3 ounces of water for a 2 pound bag of HatchRite Vermiculite may be very dry so use your judgment on how much water to add The consistency should not allow for the substrate to stick together when pressed between your fingers gt For high humidity operation 80 95 Fill the HatchRite or vermiculite incubation sand purchased separately into the small incubating tray as shown above in Fig 2 Now fill the small incubating tray with
10. ming settings Size 19 7 X L 16 1 x H 6 3 Fuse Standard 2 0Amp 250V 5X20mm Visit our web site www Reptilelncubator com for more information on all Juragon Reptile Incubators Warranty or non warranty service is provided by sending an email to us by visiting www Reptilelncubator com Juragon Digital Reptile Incubators are designed for easy and convenient use Incubator design how to use etc can be changed without advance notice Manufactured by we AUTO ELEX CO LTD Exclusive USA Canada Distributor Kemp s Reptire Incusators EUGENE OREGON USA ToL Free 888 901 2473 Www REPTILEINCUBATOR COM 11
11. ot covered under warranty To prevent this problem disassemble main body 1 and 2 and dry completely before storing You can dry the incubator by operating the incubator for at least 2 hours after removing all water 14 Incubator Reset Warning DO NOT PEFORM THIS FUNCTION OR YOUR HUMIDITY AND TEMPERATURE CALIBRATION WILL BE RESET TO FACTORY SETTINGS THAT ARE NOT VERY ACCURATE Your incubator requires recalibration if you reset it Recalibration is not covered under warranty but can be made by any competent person with a very accurate thermometer and accurate humidity meter The unit we use at the factory is a 1500 temperature humidity meter that is very accurate ALL RESET For returning to the factory setting gt If you want to return to the initial setting values by resetting the incubator follow this sequence 1 Select All Reset with SET UP mode button 2 Press Enter 3 Press OK 15 How to Clean after Hatching e Unplug the electric cord from the rear incubator receptacle and remove the electric cord plug from the wall outlet e Unlock the three locking buttons at the front and rear of incubator and disassemble the incubator e Disassemble the incubator The bottom part shall be thoroughly cleaned with water and dried The upper parts shall be naturally dried in order to remove moisture inside the incubator Allow to dry for 24 hours Assemble the parts in the reverse order of disassembly e There
12. tialization DO NOT RESET Service Center Only i A F How to change How to turn off Humidification Function Screen If you want to operate with low humidity on Incubation UNDER 40 11 How to start incubation Auto or Manual Modes Yvig amp 3 Others ye i 8 ay vs 6 87 F a 3H G 0 0 91 cil te B amp gt Chamaelaen E SRL Alligaigi Gecko Turtle Tortoise Olhers k MANUAL screen 5 85 F t 88 85 F 88 mm Ki HE Screen showing incubation for Chameleons is IN progress HOME screen before Starting incubation progress QUICK SET button Selection of Reptiles Auto incubation ENTER button Auto incubation starts after two seconds Temperature setting MENU button Humidity setting OTHER MANUAL incubation UP DOWN button Selection of Reptiles Daily Temp Gap Setting i ENTER button ks 4 Incubation starts MENU button UP DOWN button Incubation completion yes selection terminate incubation ENTER button incubation termination gt Incubation environments such as temperature humidity etc are preset in automatic mode User only needs to select the type of reptile User can make changes to incubation environment at any time if necessary Screen showing incubation of Other Reptiles is in System finish Are you sure Screen showing termination of incubation Temperature
13. tion 10 aS Tinj How to Calibrate Place your very accurate thermometer and hygrometer in the top of the egg tray filled with your egg hatching substrate Operate it for two hours before starting the calibration Z Be sure to check ALL CAUTIONS mentioned earlier in this instruction book before you ever calibrate the temperature or humidity gt Temperature is calibrated 3 times over a 90 minute period once every 30 minutes After the temperature is calibrated and matches your thermometer you can then calibrate the humidity After operating the incubator press the SET UP button and select T CAL on incubation screen Then adjust the temperature with the UP DOWN button to match what your thermometer reads and press the ENTER button to save the new setting gt Humidity is then calibrated 4 times over the next 2 hour period once every 30 minutes After operating the incubator press the SET UP button and select H CAL on incubation screen Then adjust the humidity with the UP DOWN button to match what your humidity meter reads and press the ENTER button to save the new setting After the humidity is calibrated and matches your humidity meter you are finished 17 Juragon Pro Incubator Specifications AC 100V 120V 50 60Hz Special Order in AC 220V 240V 50 60Hz Room Temperature Ideal 66 F 73 62 F 78 F for 66 F 82 F Operation 79 F 88 F for 83 F 92 F Operation Humidity Limits 40 95 Can be changed according to program
14. tor Risk of knocking he incubator atan TS incubation results Risk of damage to the and view window can fall over or risk of fire or incubator and eggs off electric shock Do not disassemble or Please be sure that If you hear strange Clean the incubator If the incubator modify the incubator in small objects do not sounds or see smoke thoroughly before requires repair unplug any manner get into Incubator immediately unplug it storing see power cord and Risk if electric shock or Risk of electric shock and contact your service cleaning section contact the service fire or fire center Risk of electric Unplug power center located on the shock or fire before cleaning last page Cleaning Cautions Do not spray cleanser Clean the incubator Do not use chemicals For a very dirty unit directly on the with a soft cotton After cleaning brush like wax benzene that requires cleaning incubator surface cloth and warm water away dust on the plug alcohol paint thinner of inner parts please mixed with 5 with a dry cloth Aromatic cleansers or contact the service bleach Do not oil lubricants etc center located on the exceed 5 bleach last page 2 Part Identification Chart Power Receptacle Vents for low volume air rear of incubator circulation Power cord plugs in Internal circulation of warm air Egg Hatching Tray Tray for HatchRite substrate or vermiculite incubation sand and your reptile eggs Air
15. ury the lower 90 of the eggs into the HatchRite or Vermiculite as shown in Fig 2 above Check the conditions of the eggs once a week Remove unfertilized eggs or eggs covered with mold 5 Check the water level for humidification everyday and fill it up as shown in Fig 5 Stop filling water when the Styrofoam ball floats near the top Suggested use of distilled water to orevent mineral buildup on heating unit although not required a 5 Humidification Figure 5 Heater Part Do not reuse hatching substrate Figure 6 7 Control Panel Operation Menu Button UP Button Select Reptile Species or Terminate Incubation eeo ce Quick Set Button rset ci aa DOWN Button hae OF Select Auto Manual _ er 3 Gr 20 90 0 Proceed to next orogramming stage Fb orites incubator Auforrete Tinpan and Humidity Control 4 Dely Temperaire Gap Funden Input Button Enter input value Proceed to next stage Set Up Button Special features such as reset and calibrate DO NOT RESET OR CALIBRATE WITHOUT READING WARNINGS 8 Display Explanation on fo y Chameleon Reptile Icon b Torlolge Selection Display Species of Reptile Selected Heater Off Display Heater On Display Humidification Off Display Low Circulation Fan Humidification On Display Active Display Daily Temp Gap Hours Window Closed Setting Value Display Window Opened Current Temperature
Download Pdf Manuals
Related Search
Related Contents
Proiettore digitale Manual del usuario San Jose Navigation GM-158-USB User's Manual Les subventions - DRJSCS des Pays de la Loire 取付 ・ 取扱呂元明書 ・ User Manual (Detecting device UDMN-100) y descarga el manual de usuario パーソナルコンピュータの 環境設計アセスメントガイドライン 第 1.2 版 Copyright © All rights reserved.
Failed to retrieve file