D24 Installers Manual

image

Contents

1. 350W x 270H x 120D mm Plug Pack we 240V AC output 17V AC 1 4A Power Supply 13 8V DC 800mA Quiescent Current 80mA with 1 Keypad Operating Voltage 9 5V 14V DC Rechargeable Battery 12V 7 0 Amp hour lead acid Battery Charging current 350mA maximum current limited Dynamic Battery Test Every Hour and on arming 10 75V with a 5 amp load 222 tes Eds 2 Amp resettable sirens amp reset 500mA resettable 12 volt auxiliary outputs 200 mA resettable strobe output INPUTS ZONES 24 physical zone inputs 2 physical 24hr Tamper inputs End of line resistor 1 x 2200 Ohm 2 2K Remote Keypad input Proprietary Maximum Keypads 3 Header Multi pin connector for the Ness Radio Interface 100 200 OUTPUTS BU Open Collector output sink current 50mA Bele ec ettet tf Changeover relay contacts rated 2A 24V DIOL AY uy On board siren driver Timed output DING B ip c On board siren driver Timed output Maximum 3 x 8 Ohm horn speakers over both outputs DIODE hed lial 12V DC latching output Maximum 2 x 1 Watt strobe lights tne 12V DC timed output Maximum 3 x 12V piezo screamers Equipment power output 13 8V DC output for powering detectors and other equipment Maximum 500mA PACKING LIST 100 660 Ness D
2. rogram the keypad icons display the PROGRAM E soon m history of Arming Disarming D and alarm events z TEST Pon ELS Press E to cancel the NESS D24 CONTROL PANEL INSTALLER MANUAL Memory display at any time PROGRAMMING QUICK START PROGRAMMING FROM POWER UP The D24 comes programmed with factory default values that should suit most average installations The steps below will show you how to program the Master Code User Code 1 and the Client Code and telephone number for central station monitoring The installation must be complete all Zones wired and sealed tampers connected keypad wired PROGRAMMING SEQUENCE To enter Installer Program Mode Power up the panel with the J1 link removed or with the box lid open if using the Tamper Lead Assembly See Main Board Wiring Diagram page 6 The PROGRAM light will be flashing PROGRAM To program the Master Code Example Master Code is 1234 Press WOB VOOM 444 1 isthe option for Enter the new Master Code Enter the new Master Code again the Master Code followed by E followed by E To program the dialler Client Code Example Client Code is 9876 Press WOWO S CD CCS CO P50E is the option for Enter the new Client Code the Client Code The keypad display will flash out the new code To program the central station telephone number Example telephone number is 1234 7890 Press HOVE COGD GU CO 8 S CO CE
3. XOS XU IE IE Ir SJ9A09 U8JIS 559 YIM cr n009 c00 19 HOLIMS H3dlAVL OL L ION 3 3 NYOH 8 N3UIS 8 NYS NHS SaUse ue suo 0LL ION H3MV3dS NYOH V N3UIS MS Q q31 1V381HV3H 380815 00 10N 1 9 1 390918 139081 13539 LVH dOL 10 9 13598 221 001 3 SS3N D ON 83 8 Asayyeg dnyoeq IH UV 1990007 G o WOO NOIL23NNO2 Gb ON AV T3H QD ved jeuondo u3aNvexa 41 0 ved OL o paiddns 2 901 QV31AH3LLV8 SLONGOYWd ALIYNOAS SSAN xnv 3 peu 9v ALL E be ov ALI EBE MNISLVSAH UUM Pa 8 peiddng Ajuo enensny ie e el 620 078 MOWd 919 9v ALL A Bullle sui ueuw SIHL 607 GGZ 007 614 814 912 SIZ VIZ 614 012 HZ 014 62 84 LZ 9Z GZ rZ Z LZ amp SUS SI S SUS 2 9E SUS SIE SUS S 169 SO sS 2 sN N N N gt IN x Nj OI M x N N N N NE IN N N N N x N N IN N ZONE INPUTS 1 zM one 24 NESS D24 CONTROL PANEL INSTALLER MANUAL D 4
4. Factory default settings shown ASSIGNING ZONES TO AREAS P310E Assign zones to Administrator area When a zone is assigned to the Admin area it is automatically removed from all other areas P310E is used only to add zones to the Admin area When a zone is assigned to any other area it is automatically removed from the Admin area P311E Assign or remove zones from Area 1 P312E Assign or remove zones from Area 2 P313E Assign or remove zones from Area 3 ASSIGNING MONITOR ZONES Monitor mode allows partial arming of the system eg for night time perimeter protection If also using Area Partitioning assign Area 1 zones to Monitor 1 and Area 2 zones to Monitor 2 P321E Assign zones to Monitor 1 P322E Assign zones to Monitor 2 EU 55 5 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT shortcut Arming amp shortcut Exclude ON TO PROGRAM P 33 E Option E Toggles the option ON and OFF NOTES PROGRAMMING OPTION No DESCRIPTION DEFAULT KEYPAD SHORTCUTS 1E Two button keypad operation 2 Shortcut ARMING Shortcut EXCLUDE KEYPAD SHORTCUTS These options will determine the keystrokes required to Arm Monitor Exclude Panic View P33E 1E Two button keypad operation If this option is on the ENTER button is also required for the above operations E g Press ARM ENTER to Arm MONITOR ENTER to Monitor etc Otherwise the keypad operation is single button
5. POE Code retry limit 4i Map Tamper Alarms to Contact ID Various see page 31 Owespefk 18 Map System Alarms to Contact ID PME Map Power Alarms to Contact ID Enable multiple zone alarm reports O N o 32 Disable multiple zone alarm reports P66E 1 Send Restorals after Siren Time 32 2E Send Restorals on Disarm Send Restorals immediately ON OPE Program Installer Code 4E Do not send Restorals Exit Program Mode P67E Mains Fail reporting delay These options are available in User Program Mode P68E Abort Delay 38 P981E Default panel options Except Dialler Codes amp delays 41 P982E Default User Codes Installer code amp Entry Exit delays P983E Default dialler options P984E Clear Alarm Memory P985E Clear dialler buffer ALL options are available in Installer Program Mode dL NESS D24 CONTROL PANEL INSTALLER MANUAL D 24 DIALLER SECURITY ALARM PANEL INSTALLATION RECORD Zone mapping gt gt o T P20E Instant P21E Entry Delay P22E Handover P17E Entry Delay Time Seconds P170E Entry Delay Time multiple areas Seconds P171E Entry Delay Time for AREA 1 Seconds P172E Entry Delay Time for AREA 2 Seconds P173E Entry Delay Time for AREA 3 Seconds P18E Exit Delay Time Seconds P181E Exit Delay Time for AREA 1 Seconds P182E Exit Delay Time for AREA 2 Seconds P183E Exit Delay Time for AREA
6. Tamper Alarm mapping Pesta Tamper te 2 Radio Tamper se _ P292E Siren Lockout P302E Excludable P39xxE Map to Output Group P62E Contact ID channel System Alarm mapping Keyswitch Panic Dialler line fault 2E Keypad connection fault 3E Control Panel fault 4E Duress alarm 5E Panic alarm eE Medical alarm User Code alarm 8E Access to Installer Program mode 9E Power Alarm mapping Tick Sl i POWER ALARMS 3 P293E Siren Lockout P303E Excludable P40xxE Map to Output Group P63E Contact ID channel P294E Siren Lockout P304E Excludable P41xxE Map to Output Group P64E Contact ID channel Backup Battery low DC supply failed Zone reference supply failed Radio Device battery low Radio Key battery low E O O CONTACT ID REPORTING CODES Contact ID Event Code XYZ Alarm number CCC 130 Burglary Zone 001 to 024 120 Keyswitch Panic 025 137 External tamper 026 301 Mains fail 027 309 Panel Low Battery 028 307 13 8 Volt Supply fail 029 307 Zone Reference Voltage fail 030 350 Telephone Line fail 031 307 Keypad Buss fail 032 137 Control Panel tamper 033 307 Control panel fault diagnostic 034 121 Duress alarm 035 120 24 Hour alarm PANIC 036 100 Medical alarm 037 137 Code alarm retry limit exceeded 038 144 Keyswitch tamper 047
7. to Contact ID channels OPTION No DESCRIPTION Map TAMPER ALARMS DEFAULT CHANNEL External Tamper to Contact ID channels Control Panel Tamper Zone input Tamper Map SYSTEM ALARMS Radio Interface Tamper Keyswitch Panic to Contact ID channels Dialler line fault Keypad connection fault Control Panel fault Duress alarm Panic alarm Medical alarm User Code alarm Map POWER ALARMS Access to Installer Program mode Mains power failure to Contact ID channels Backup Battery low DC supply failed Zone reference supply failed Radio Device battery low Radio Key battery low MAPPING CONTACT ID CHANNELS All alarm types report a preset Contact ID code to the central station These codes do not normally need to be changed EXAMPLE To program zone 12 to report it s alarms on Contact ID channel 120 P61E 12E 120E To disable a zone or other alarm from reporting enter zero as the reporting channel alarm zone number E See page 58 for the full list of Contact ID reporting codes PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Multiple reporting disabled TO PROGRAM P65E 1E to disable multiple alarm reporting P65E 2E to enable multiple alarm reporting PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 3E on Restorals sent immediately TO PROGRAM P
8. Enter 3 beeps new value NESS D24 CONTROL PANEL INSTALLER MANUAL EE P1E P030E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT blank TO PROGRAM P Option No E new code E new code E NOTES User Codes can be 3 to 6 digits in length User codes cannot start with 0 All codes must be unique to each other The panel is supplied with NO user codes programmed To delete a code re program the code as 000 e g To Delete User Code 2 P2E 000E 000E To clear all codes enter P982E in Installer Program mode See Page 41 Codes are rejected if already used Some codes that are similar to existing codes may also be rejected Open Close reports are identified by user number when the control panel is central station monitored RELATED OPTIONS Program Installer Code page 40 Ws coup me mt UO mE mt UO mt Tueros mE mt wes mt wes m wecen mm mmt mut ser code mme UO mmt mmt Wecen mex mmt me usere mmt me mm eoe mmt Wecwem PROGRAMMING USER CODES 1 30 User codes are the PI N codes used to operate various panel functions espec
9. INEZ D 24 NESS D24 CONTROL PANEL AND DIALLER INSTALLATION amp PROGRAMMING MANUAL NESS D24 CONTROL PANEL INSTALLATION MANUAL A 15 00 INC GST 1 1 Australia s largest designer and manufacturer of high quality security products 55 NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company 1509001 LIC No QEC2074 NSW Head Office only Ness Security Products Pty Ltd 2 D gt n gt T 3 s WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ACN 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 ADELAIDE Aquavia Controls 08 8277 7255 PERTH 08 9328 2511 NEW ZEALAND NFS NZ 64 9 573 0401 REVISION 1 1 JULY 2002 D24 INSTALLER MANUAL Document Part No 890 253 Product Part No 100 660 Product description D24 Control Panel 2002 Ness Security Products Pty Ltd ABN 28 069 984 372 D24installer_rev1 1 pmo050702 Specifications may change without notice D24 features D24 Specifications Installation amp Power up procedures D24 MAIN BOARD WIRING DIAGRAM Wiring examples Inputs Outputs D24 LCD KEYPAD QUICK START PROGRAMMING Program MODE levels HOW TO ENTER PROGRAM MODE How to EXIT Program Mode Master Code
10. Monitor mode P3720E All zones selected on Output Group 20 24hr zones P380E All zones selected on Output Group 0 disabled P35xxE P38xxE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P Option No E Output Group E Zone E Maps zones to the selected output group NOTES e Zones can be disabled by mapping them to Output Group 0 e Zones are removed from an output group by mapping them to a different output group Output Groups list see page 24 EXAMPLE 1 To make zones 23 amp 24 into 24hr zones by mapping them to output group 17 P3817E 23E 24E EXAMPLE 2 To map zones 1 2 3 amp 4 to output group 20 when Armed P3520E 1E 2E 3E 4E MAP ZONES TO OUTPUT GROUPS These options set the output groups which any zone will trigger when alarmed Zones can be setup to trigger a different output in each panel state P35xxE ARMED Map zones to output groups to be triggered when the panel is Armed P35 Output Group 0 31 E Zone number E Zone number E etc Factory default setting is all zones mapped to output group 17 P3517E will show all 24 zones on P36xxE DISARMED Map zones to output groups to be triggered when the panel is Disarmed P36 Output Group 0 31 E Zone number E Zone number E etc Factory default setting is all zones mapped to output group P360E will show all 24 zones on This means that all zones are disabled when the panel
11. P51E is the option for Enter the new telephone number followed by E Telephone Number 1 The keypad display will flash out the new telephone number To exit Installer Program Mode Press P followed by E The PROGRAM light will turn off THE PANEL IS NOW PROGRAMMED AS FOLLOWS Master Code 0e Example only Dialler Client Code 9876 Example only Telephone number 1234 7890 Example only Dialler reporting format Contact ID Factory default Delay Dialler Sirens Factory default ZONE 2 Handover Dialler Sirens Factory default Zones 9 24 Instant Dialler Sirens Factory default Entry Delay Time 20 seconds Factory default Exit Delay Time 60 seconds Factory default Siren Reset Time 10 minutes Factory default The client code and telephone numbers are normally allocated by the central station 12 NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAMMING PROGRAM MODE LEVELS FACTORY DEFAULT Master Code blank Power up with J1 Link OFF Installer Code 000000 Usually on first time installation 8 PROGRAM light INSTALLER PROGRAM MODE is FLASHING Installer Program Mode allows PROG
12. 144 Zone Circuit tamper 048 306 Access to Installer Program mode 056 384 Radio Low battery 070 602 Automatic Test call 056 383 Radio Tamper Device By Device ID 380 Auto Exclude By Device ID 573 Manual Exclude By Device ID 401 Open Close with user ID By User ID 120 Radio Key panic By User ID 406 Cancel of Alarm report By User ID Notes This map represents the default settings If using area partition Admin area Group 1 Area 1 Group 2 Area 2 Group 3 and Area 3 Group4 Some central stations do not accept Group 0 NESS 024 CONTROL PANEL INSTALLER MANUAL Se NOTES NESS D24 CONTROL PANEL INSTALLER MANUAL EJ This page is intentionally blank
13. Medical Alarm button 2 If the Medical Alarm Delay s being used an instant Medical Alarm can be sent by pressing the button twice within 12 seconds On the first press the keypad s will beep once per second during the 12 second period On the second press the keypad s will beep fast to indicate that the Medical Alarm has been reported INACTIVITY MEDICAL ALARM NOTE OPERATION If Inactivity Medical Alarm is The Inactivity Medical Alarm can be used to summon assistance if a person has enabled the client should become incapacitated and is not able to press their Medical Alarm button give notice to their monitoring station if they plan to be For example if the Medical Alarm Delay is set for 24 hours the Medical Alarm will absent from the premises for be triggered if the button is not pressed every 24 hours Effectively it is an I m extended periods holidays button visits etc When 20 minutes of the Medical Alarm Delay time remains and the Medical Alarm button has not been pressed the keypad s will beep for 10 seconds as a reminder As a final warning that the Medical Alarm delay is due to expire the keypad s will beep continuously during the final 10 minutes MEDICAL ALARM BUTTON The Medical Alarm button can be setup to take the place of the keypad Panic button or it may be a separate button This must be determined by your installer Medical alarm is number 7 in the A view FIRE ALARM Your system m
14. P1E User Codes 1 30 2 ENTRY DELAY TIMERS P17E EXIT DELAY TIME P18E Siren Reset Time P28E ZONE ASSIGNMENT 19 23 Zone Input response time P252E P258E Vibration Sensitivity P261E P268E Siren Lockout P291E P294E Excludable Alarms P301E PS304E AREA PARTITIONING Assigning Zones to Areas P310E P313E Assigning Monitor Zones P321E P322E Keypad Shortcuts P33E Misc System Options P34E Map zones to output groups P35xxE P38xxE Map Alarms to output groups 9 42 OUTPUT GROUPS amp OUTPUTS DEFINED Creating Installer defined output groups Zones with no Exit Delay P441E Test Options P45E CLIENT CODE P50E TELEPHONE NUMBER 1 P51E Telephone Number 2 P52E Telephone Number 3 Callback P53E REPORTING FORMAT P54E Dialling Format P55E Alternate Dialling P57E Remote Access Options P58E Required rings to Auto Answer P59E Open Close Reporting Options P60E 10 12 13 13 13 14 14 15 15 15 16 17 17 18 18 19 19 19 20 21 22 23 24 25 26 26 27 27 27 27 28 29 29 30 30 30 5 Mapping Contact ID Channels P61E P64E Multiple Alarm Reporting P65E Restorals Reporting P66E Mains Fail Reporting Delay P67E Zone reporting Abort Delay P68E P69E Test calls P70E P71E Easycall dialling P72E P74E Area Client codes P750E P753E Enable Options P82E NESS RADIO
15. P33E 2E Shortcut ARMING If this option is on a user code is not required to Arm Shortcut EXCLUDE If this option is on a user code is not required to Exclude P33E SUMMARY 1E OFF 2E ON 3E ON Single button Arm Monitor Exclude 1E ON 2E OFF ON Arm Monitor via code 1E ON 2E ON 3E OFF Arm Monitor Exclude via code or 2 button Arm Monitor Exclude E 20 NESS D24 CONTROL PANEL INSTALLER MANUAL P34E 1E 8E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P 34 E Option E Toggles the option ON and OFF NOTES SIREN CHIRP By default the KEY input is a Panic input To use the KEY input as a keyswitch input program P400E 1E this maps the input to Output Group zero which disables it as a zone RELATED OPTIONS P40xxE 1E Mapping Keyswitch Panic KEY input to Output Groups page 23 NESS D24 CONTROL PANEL INSTALLER MANUAL 21 PROGRAMMING OPTION No DESCRIPTION DEFAULT MISC SYSTEM OPTIONS 1E Keyswitch unrestricted operation 2E Chirp siren on K S Arm Disarm 3E Disable Auto exclude 4E Entry beeps 5E 6E Auxi Armed output 8E Zone unsealed warning on Arming MISC SYSTEM OPTIONS P34E 1E KEYSWITCH UNRESTRICTED OPERATION OFF A delay zone must be activated before operating the keyswitch otherwise an alarm will occur ON The keyswitch operates at all times P34E 2E CHIRP SIREN ON K
16. SYSTEM NUMBER E ete The selected System numbers will turn on TO EXCLUDE POWER ALARMS Press 4 E S and CD will be on POWER NUMBER E ete The selected Power numbers will turn on TO EXIT EXCLUDE MODE Press E D will flash while Disarmed and Armed 48 NESS D24 CONTROL PANEL INSTALLER MANUAL This section is repeated on page 26 NESS D24 CONTROL PANEL INSTALLER MANUAL E OPERATION TEST MODE Test Mode allows the user to manually test all audible and visual outputs without alarming the panel In normal operating mode Press CODE E The icon will turn on Press the keys below to operate each output Press the same key to turn the output off Pressing any other key will test that output and cancel the current output Press E To exit Siren test mode KEY INDICATOR OUTPUT KEYPAD BEEPS SIREN A Tone 2 SIREN B Tone 2 1 1 SIREN A Tone 1 2 2 SIREN B Tone 1 3 3 RESET internal screamer 4 4 STROBE 5 5 AUX 1 6 6 AUX 2 7 7 8 1 9 2 TEST OPTIONS P45E 1E INSTALLATION WALK TEST MODE This test runs in installer program mode while P45E 1E is selected Outside of installer program mode the test is supended but the zone selection remains ON Installation Walk Test Mode is enabled To enter test mode press P45E 1E The icon will fast flash zone number E zone number E select or de select the zones to test As each zone is selected the corresponding zone i
17. can be included in the dialling sequence by using the keys in the table below SPECIAL CHARACTER PAUSE 1 6sec Star Hash KEY ENTRY AREA Key ARM Key MONITOR Key INDICATION ON LCD DISPLAY 6 Flashing 2 Flashing 3 Flashing NESS 524 CONTROL PANEL INSTALLER MANUAL P750E P753E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0000 TO PROGRAM P 75x E Client Code E RELATED OPTIONS P6OE Send Open Close with Client Codes as per P75xE P80E P81E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2E on Dialler enabled 3E off Radio Interface disabled 4E off Output Expander disabled TO PROGRAM P82E Select option E NESS D24 CONTROL PANEL INSTALLER MANUAL D PROG DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT ADMIN Area client code AREA 1client code AREA 2client code AREA 3client code AREA CLIENT CODES These options are for programming individual client codes for each Area Option P6OE 3E must also be on P750E Admin Area client code P751E Area 1 client code P752E Area 2 client code P753E Area 3 client code CREATE INSTALLER DEFINED OUTPUT GROUPS METHOD 2 See page 25 OPTION No DESCRIPTION DEFAULT ENABLE OPTIONS not used Enable Dialler Enable Radio Interface Enable Output Expander ENABLE OPTIONS P82E 1E Not used P82E 2E ENABLE THE DIALLER On by default This option
18. connected for correct panel operation Observe correct polarity when connecting the battery Ness Part No BAT210 12V 7Ah battery J1 TAMPER Internal Tamper Input amp Program Link The J1 link has two purposes 1 To enter Installer Program Mode on initial power up Power up with the J1 link OFF The J1 link must be ON in operating mode Or if using J1 for housing tamper the tamper switch es must be sealed 2 Housing Tamper When used with the Internal Tamper Lead supplied J1 serves as the 24hr tamper input for the panel s internal tamper switch Replace the J1 link with the Internal Tamper Lead and tamper switches An EOL resistor is NOT required on this input When J1 is used for internal tamper powering up with the panel s lid open will enter Installer Program Mode 8 NESS D24 CONTROL PANEL INSTALLER MANUAL OUTPUT FUSING The 12V ouputs Siren Reset and Strobe Outputs are protected by Automatic Reset electronic fuses These outputs will automatically reset once the overload is removed BACKUP BATTERY A properly charged battery MUST be installed to ensure the Siren Strobe and Reset outputs Operate correctly SIREN LOAD A maximum output of 2 0A continuous is available from the SIREN and RESET outputs and 200mA from the STR output Recommended maximum power load 3 X Horn speakers total SRN A and SRN B 2 x Strobe lights STR output 2 X Ness Internal Sirens 100 172 RESET output Note T
19. prefix any valid User Code with the Duress Digit when Disarming The factory default Duress Digit is 9 It can be any number from 0 9 e DURESS ALARM CAN ONLY BE USED IF THE SYSTEM IS CENTRAL STATION MONITORED By default DURESS alarms do not sound any audible alarms P40xxE Duress alarm is number 5 in the A view Disarm by pressing DURESS DIGIT User Code E The panel Disarms as normal and the Duress report is sent to the Central Monitoring Station 44 NESS D24 CONTROL PANEL INSTALLER MANUAL OPERATION MEDICAL ALARM This page is an extract from the Your system may have been setup with a Medical Alarm This type of alarm can be D24 User Manual used to summon assistance for the elderly or infirm who are living alone A Medical See Page 39 for Medical Delay Alarm is most effective if the system is monitored by a Central Monitoring Station programming Medical Alarms can be used in two ways 1 INSTANT MEDICAL ALARM Immediately sound the sirens and send a Medical Alarm report to the Central Monitoring Station In this case the Medical Alarm Delay is set at zero hours 2 INACTIVITY MEDICAL ALARM The Medical Alarm is reported if the Medical Alarm button is NOT pressed within the pre programmed Medical Alarm Delay In this case the Medical Alarm Delay is set between 1 and 24 hours INSTANT MEDICAL ALARM OPERATION 1 If the Medical Alarm Delay is not being used simply press the designated
20. 29 D PROG DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT DIALLING FORMAT Auto dialling PULSE or DTMF PULSE dialling always DTMF dialling always Alternate dialling Pri Sec numbers ALTERNATE DIALLING Dial each phone number 5 times Repeat to phone No 2 DIALLING FORMAT The D24 will dial in either DTMF or Pulse depending on the type of dial tone sensed Insome instances it may be necessary to dial in a particular format regardless of the dial tone P55E 1E AUTO DIALLING Dials in DTMF or Pulse depending on the type of dial tone sensed When this option is selected the panel will make the first dialling attempt in DTMF and the remaining attempts in Pulse dialling This is to prevent false DTMF dial tones from disabling the dialler P55E 2E PULSE DIALLING ALWAYS Always dials in Pulse Decadic format P55E DTMF DIALLING ALWAYS Always dials in DTMF Tone format ALTERNATE DIALLING P57E 1E ALTERNATE DIALLING PRI SEC NUMBERS Alternate dialling between the Primary and Secondary telephone numbers until successful Alternate dialling between the Primary and Secondary telephone numbers until successful occurs for the maximum number of 20 dial out attempts This consists of 2 rounds of 10 calls 5 per number including a sleep time of 5 minutes between attempts P57E 2E DIAL EACH PHONE NUMBER 5 TIMES Dial the Primary telephone number 5 times If unsuccessful dial the Secondary tel
21. ALARM Sonalert 12 DIALLER 13 TIMER 14 ALARM STATE 15 SIREN TONE 1 16 SIREN TONE 2 1 2 3 4 5 6 7 8 9 OUTPUTS WHAT ARE OUTPUT GROUPS Output Groups are different combinations of the 16 available outputs Any type of alarm can be mapped to an Output Group The use of Output Groups simplifies the mapping of outputs to inputs For example by mapping a zone to Output Group 17 the zone will trigger these outputs SIREN A amp SIREN B Siren Tone 1 RESET STROBE AND DIALLER Output Groups 1 15 are blank by default and can be defined by the installer Output Groups 16 91 are factory defined with commonly used combinations of outputs Any zone or alarm can be disabled by mapping it to Output Group 0 WHAT ARE OUTPUTS Outputs are physical or virtual outputs such as Siren outputs the Strobe output the Dialler etc Zones or alarms mapped to Output Group 0 will be T OUTPUT GROUPS INSTALLER DEFINED FACTORY DEFINED meas et ft r NNN s Pism 1515 1 _ LLL SEES RECA CORRES _ _ e eT tT es j 1111111 1515 fel 1515 lies _ Lg I ees I _ OUTPUTS DEFINED The D24 has 16 individual outputs which can be mapped through Output Groups to various alarms SIREN A Siren driver output for co
22. INTERFACE RADIO PROGRAMMING Clear Radio Keys P83E Program Radio Keys P831E Clear Radio Devices P84E Program Radio Devices P841E Medical Delay P93E General Purpose Timer P94E P95E INSTALLER CODE PROGRAMMING P99E Code Retry Limit P96E Duress Prefix P97E FACTORY DEFAULTS P981E P985E OPERATING THE SYSTEM Arming Disarming Arming Disarming Areas Monitor Mode Arming Panic Alarm Duress Alarm Medical Alarm Fire Alarm VIEW MENU View Memory Excluding Zones Test Mode Test Options MONITORING Central Station Monitoring Audible Monitoring REMOTE OPERATION BY TELEPHONE D24 OUTPUT EXPANDER OPTIONS SUMMARY INSTALLATION RECORD CONTACT ID CODES TABLE 31 32 32 32 33 33 34 35 35 36 37 37 37 37 37 39 40 40 41 41 41 42 43 44 44 45 46 47 48 49 49 50 90 51 52 94 55 56 57 58 D24 FEATURES Powerful multizone commercial security 24 fully programmable zones 30 User Codes Up to 8 Radio Zones Contact ID Dialler Format Ness Audible Dialler Format Separate 24 Hour Tamper input Single or Double Trigger Zones Remote LCD Keypads Max 3 Programmable Inputs to activate selectable Outputs Output Mapping Inbuilt Vibration Sensor Analyser All programming data is permanently stored in a non volatile EEprom memory True Dynamic Battery Test every time the Panel is Armed Disarmed and every hour Area Partitionable 3 Areas Any Zone can
23. PROGRAM P43 Output Group 1 15 E Output 1 16 E Maps alarms to the selected output group NOTES e This method does not provide visual feedback when programming P80xxE P81xxE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P80 Output Group 1 15 E Output 1 10 E P81 Output Group 1 15 E Output 9 16 E Maps alarms to the selected output group NOTES e This method provides visual feedback when programming NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAMMING OUTPUT GROUPS Method 2 1E Gss 2 pg F Ee 4 4 STROBE j auxi L TT s e AUX2 Relay f l 1 7 sonaleaT 1 1 1111 11 1 FRE PT TT l 9 9 SIRENABurst il 0E 10 RESET Burst 11 PREALARMSondet 2 12 DIALLER pt tt tT O j O l 3E 13 TIMER aE 14 ALARMSTATE j ll sE 15 SIRENTONE1 L L 6 16 SIRENTONE2 1 iii ililiiii CREATING INSTALLER DEFINED OUTPUT GROUPS METHOD 1 There are two methods for building your own Output Groups Method 1 uses the option P43uuE yyE yyE etc to add outputs when building Output Groups 1 15 uu Output Group 1 15 yy Output 1 16 select 1E 16E This method should only be used by experienced installers as it provides no visual f
24. S ARM DISARM Selects Siren Chirp when Arming Disarming by Keyswitch or Radio Key They KEY input must first be enabled as a keyswitch input OFF No siren chirp ON Siren chirp on Arm Disarm enabled SIREN CHIRPS ARMING One chirp from Siren B DISARM Two chirps from Siren B P34E 3E DISABLE AUTO EXCLUDE OFF Auto exclude is enabled Zones unsealed at time of Arming are automatically excluded at the end of exit delay ON Auto exclude is disabled Zones unsealed at time of Arming will activate the alarm at the end of exit delay P34E 4E ENTRY BEEPS OFF No Entry Beeps ON Keypad beeps during entry delay time P34E 5E not used P34E 6E not used P34E 7E AUX1 ARMED OUTPUT OFF Aux1 not affected by Arming ON Aux1 follows panel Arm Disarm state P34E 8E ZONE UNSEALED WARNING ON ARMING OFF No zone unsealed warning ON The RESET output will sound a 2 second alarm immediately on Arming if Arming with a zone unsealed OPTION No PANEL STATE Posee wap T P3 k MonToRMODE I L Choose an Output Group 0 31 FACTORY DEFAULTS PROGRAMMING Zones 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Turn ON the zones required to be in the selected Output Group Armed P3517E All zones selected on Output Group 17 Disarmed P360E All zones selected on Output Group 0 disabled
25. Successful Arming or Disarming An Auxiliary output has been turned ON a LONG BEEP e The panel is already Armed e Invalid code Try again 1 SHORT BEEP An Auxiliary output has been turned OFF TELEPHONE COMMANDS Prepare to receive commands Arm the panel Arm Area 1 Arm Area 2 Arm Area 3 Turn Aux 1 Output ON or OFF Turn Aux 2 Output ON or OFF 9 9 Disarm all Areas s Finished hang up The OE command arms the Admin Area This means if there are no areas programmed it arms the whole panel If areas have been programmed OE arms any zones that remain in the Admin area i e zones that have not been allocated to any area RELATED OPTIONS P58E 3E Enable remote ADMIN Arm P58E 4E Enable remote AREA 1 Arm P58E 5E Enable remote AREA 2 Arm P58E 6E Enable remote AREA 3 Arm P58E 7E Enable remote AUX1 AUX2 P58E 8E Enable remote Disarm all Areas NESS D24 CONTROL PANEL INSTALLER MANUAL REMOTE OPERATION BY TELEPHONE OPERATING THE D24 BY TELEPHONE The D24 control panel will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To maintain panel security remote operations can only be carried out after entering a valid user code To operate the panel by telephone you need a DTMF capable telephone a valid User Code and you must know the Telephone number of the line to which the panel
26. WIRING EXAMPLES DETECTORS 4 WIRE CONNECTION NO TAMPER DETECTORS 6 WIRE CONNECTION WITH TAMPER score wen ME OV 0V 12V H12V Any zone Z N C of ALARM No TAMPER SIREN WIRING EXTERNAL INTERNAL ALTERNATIVE 12V SIRENS 100 172 Ness 12V Internal Siren ind NOI240 8100 12V Piezo Screamer 2 761 002 Colour BLACK 100 238 Top Hat 12V Piezo Screamer Ness Panel amp Noise KITS are supplied with the Ness Internal RESET Horn Speaker 100 171 This must RESET be connected to the SIREN output in parallel with the Horn Speaker s SIREN IDENTIFICATION WHITE ENSE The terminal block should STROBE LIGHT be mounted inside the NOI300 WHITE siren cover 100 171 Ness Internal Horn Speaker WHITE wires ALTERNATIVE TAMPER SWITCH WIRING N C TAMPER SWITCH For N C Tamper Switches SWI920 Colour WHITE RED BLACK 100 172 TAMP Ness 12V Internal Siren RED amp BLACK wires T Pe eee ee eee ee te eee Connects to RESET output NESS D24 CONTROL PANEL INSTALLER MANUAL 1 w INPUTS TESTING ZONE INPUTS ZONE INPUTS 1 24 Installers note When The Ness D24 has 24 End Of Line monitored zone inputs Each zone input must troubleshooting your zone wiring be terminated with a 2K2 2200 ohm End Of Line EOL resistor as supplied the voltages across the z
27. Zones have an entry delay time eqivalent to the Exit Delay Time P18E P271E Single Trigger is the default for all zones The zone alarms on each single trigger P272E Zones programmed to Double Trigger will recognise an alarm condition if The Double Trigger zone has been triggered twice within a 4 minute period f any 2 Double Trigger zones each trigger once A Double Trigger zone is left unsealed for longer than 15 seconds Double Trigger is suitable for zones with devices such as PIRs which self reset NESS 524 CONTROL PANEL INSTALLER MANUAL OPTION No TIME milliseconds 1 2 3 4 5 6 7 PROGRAMMING 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 SELECTION GROUP 440 Normal ON ON ON ON Only one 480 option is selectable 520 per zone 560 600 P251E 258 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT P254E All zones Normal Sensitivity TO PROGRAM P Option No E Zone No E Turns the option ON for each zone selected OPTION No SELECTION GROUP PULSES within600ms 1 2 3 4 5 6 7 Factory default settings shown ZONE INPUT RESPONSE TIME P251E P258E The input response time can be adjusted for each zone The factory default is 440ms This option does NOT normally need to be adjusted This option is NOT related to Vibration Sensitivity Zones are allocated to one sensitivity level at any one time Tur
28. be programmed to any area as well as common areas Two separate Monitor Modes Home Mode Outputs are separately fused with Automatic Reset Fuses Day Mode feature 30 Event Memory Supports 8 Radio Devices Radio PIRs Radio Reeds etc Supports 8 Radio Keys All inputs and outputs are heavily protected against lightning and high voltage supply transients An earth terminal is provided for extra protection Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain system security under all power supply conditions Manufactured with the latest SMD Technology Ultra Modern and Impact resistant housing INTRODUCTION The D24 alarm control panel is wholly Australian designed and manufactured by Ness Security Products Australia s largest manufacturer of quality electronic security products Ness Security Products is a Quality Accredited Company to ISO 9001 The Ness D24 alarm control panel has been designed to provide you the security professional with a 24 zone hardwired including 8 wireless zones control panel featuring ease of installation ease of programming and user friendly operation in a package which is functional and attractive The design and build of this product is based on the Ness philosophy of excellence without compromise Supplied with the D24 LCD Keypad D24 SPECIFICATIONS Construction 3mm Polycarbonate equiv 1 2mm mild steel Dimensions
29. device POWER 0 Radio Key battery low Zone indicators 1 8 will show which Radio Key NESS D24 CONTROL PANEL INSTALLER MANUAL m MEMORY EVENTS INDICATED BY KEYPAD ICONS ICON MEMORY and 1 24 ZONE flashing and 1 5 TAMPER and 1 8 SYSTEM D and 1 0 POWER A and 1 24 FIRE flashing ARM ZONE MONITOR slow flash AREA 1 slow flash AREA 2 slow flash NESS D24 CONTROL PANEL INSTALLER MANUAL EVENT Events are from memory Zone alarms Tamper alarms System alarms Power alarms Fire Zone alarm Arm Disarm Monitor Mode Area 1 Arm Area 2 Arm Area 3 Arm Area 1 Monitor Mode Area 2 Monitor Mode OPERATION HOW TO VIEW MEMORY 1 When the JU icon is flashing to indicate there is a new alarm in memory pressing C viEW2 will display an icon for example Zone Tamper System etc and a number to indicate the type of alarm 2 In normal idle mode system is disarmed with the icon displayed the memory history can be displayed in sequence To view the Memory History Press CVIEW2 E the icon will turn on Then press Cvigw2 Repeat presses At each step the keypad icons will display past events The Zone Tamper System and Power icons will indicate what type of events are being displayed Memory is displayed backwards from most recent event to the end of memory The past 50 events are stored Press
30. is connected NOTES 1 If the D24 does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up 2 You can keep the panel on line by regularly pressing the o button on the telephone 3 If an alarm occurs which requires the D24 to dial out the D24 will treat the alarm as a priority give a constant tone as a warning and then hang up It will then pick up the line again to report the alarm as programmed 4 When all remote control commands are finished press x st to force the D24 to hang up OPERATION 1 Phone the D24 telephone number and listen for the required number of rings ring ring ring ring and then hang up Default is 1 ring 2 Call the number again within 60 seconds 3 The D24 will answer the second call immediately sound a beep for 2 seconds then after a pause it will sound a lower frequency tone The panel is now ready to receive telephone commands 4 Press the 0 button on the telephone This tells the D24 that telephone commands will follow The D24 will respond with either 3 beeps if all OK or one long beep to try again 5 Now enter a valid User Code followed by the 8 button Use a code that is normally used for Arming or Disarming the D24 The D24 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again 6 Enter the required command See Summary O
31. of Exit Delay Time 1 beep will sound J TO DISARM YOUR AREA To Disarm the Area assigned to your code simply enter your code followed by E Press CODE E Three beeps will sound 44 and the respective AREA icon will turn OFF Q or 2 or EA 1 AREA 2 AREA 3 TO ARM AREAS USING AN ADMINISTRATOR CODE Using an Administrator Code to Arm selected Areas Press 2 cong E 0r to Arm multiple Areas at once 1 E and or 2 E and or 3 E CODE E Three beeps will sound see and the selected AREA icon s will turn ON AREA 1 AREA 2 AREA 3 Leave the Area within the Exit Delay Time At the end of Exit Delay Time 1 beep will sound J TO DISARM AREAS USING AN ADMINISTRATOR CODE Using an Administrator Code to Disarm selected Areas Press 1 2or3 CE cove E 0r to Disarm multiple Areas at once C1 CE anior 2 E andlor 3 CE cone E Three beeps will sound see and the selected AREA icon s will turn OFF Q 2 AREA 3 0r a shortcut to Disarm all Areas Press CODE E Three beeps will sound and all AREA icons will turn OFF Q or 2 or EA 1 AREA 2 AREA 3 NESS D24 CONTROL PANEL INSTALLER MANUAL 48 OPERATION ZONES MUST BE SEALED MONITOR MODE ARMING Make sure that all zones in the Monitor area U Monitor mode allows you to Arm selected zones while others are ignored are sealed before Arming Monitor mode Typically used t
32. press the keypad s will beep once per second during the 12 second period On the second press the keypad s will beep fast to indicate that the Medical Alarm has been reported INACTIVITY MEDICAL ALARM OPERATION The Inactivity Medical Alarm can be used to summon assistance if a person has become incapacitated and is not able to press their Medical Alarm button For example if the Medical Alarm Delay is set for 24 hours the Medical Alarm will be triggered if the button is not pressed every 24 hours When 20 minutes of the Medical Alarm Delay time remains and the Medical Alarm button has not been pressed the keypad s will beep for 10 seconds as a reminder As a final warning that the Medical Alarm delay is due to expire the keypad s will beep continuously during the final 10 minutes NESS D24 CONTROL PANEL INSTALLER MANUAL Ey P94E 95 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 94 0 sec disabled P95E 0 sec disabled TO PROGRAM P94E time E P95E time E Enter 0 100 seconds or 101 220 for 1 120 minutes RELATED OPTIONS P42xxE 1E To map the GPT to an Output Group See page 23 NOTE If you program the timer to control an output the timer will take priority over any other function For example if you program the timer to pulse the Siren for 10 seconds and the siren has been triggered by a zone to run for the Reset time i e 10 minutes the Siren will turn off aft
33. pressing VIEW from the normal zone display mode will display the last event TO VIEW THE STATUS OF ALL ALARMS Press view Repeat presses Repeated presses of the VIEW button will cycle viewing of Zone Tamper System Power and Memory sub menus Or each sub menu can be directly viewed by pressing 1 6 CE TO VIEW ZONES PRESS VIEW 1 E The zone indicators 1 24 will show the state of the 24 zones and possibly one or more other icons flashing to indicate other alarms T TO VIEW TAMPERS PRESS CuEw 2 Zone indicators will show the state of the four Tamper inputs TAMPER 1 External Tamper alarm TAMPER 2 Control Panel Tamper alarm TAMPER 3 Zone Input Tamper alarm TAMPER 5 Radio Interface Tamper alarm TO VIEW SYSTEM A PRESS View 3 Zone indicators will show the state of the eight System inputs SYSTEM 1 Keyswitch Panic SYSTEM 2 Dialler line fault SYSTEM 3 Keypad connection fault SYSTEM 4 Control panel fault SYSTEM 5 Duress Alarm SYSTEM 6 Panic Alarm SYSTEM 7 Medical Alarm SYSTEM 8 User Code Alarm SYSTEM 9 Access to Installer Program mode TO VIEW POWER CD PRESS VIEW 4 E Zone indicators will show the state of the six Power alarms POWER 1 Mains power failure POWER 2 Control panel backup battery is low POWER 3 DC supply failure POWER 4 Zone reference power failure POWER 9 Radio device battery low Zone indicators 1 8 will show which
34. 24 Control Panel 12V 7Ah battery optional User manual optional Lead assembly Dialler 1 D24 main board 1 Installer manual optional 1 D24 Power Board 30 2 2K End Of Line resistors 1 D24 housing 54 4 7K End Of Line resistors 1 Ness D24 LCD keypad Lead assembly Battery 1 17VAC plug pack Lead assembly Internal Tamper 1 1 Zone list label 4 NESS D24 CONTROL PANEL INSTALLER MANUAL POWERING UP After wiring power up as follows 1 Make sure the J1 pins are open remove the link or unseal the lid tamper switch This condition forces the panel to enter installer program mode on power up 2 Connect the battery observe correct polarity and connect the plug pack 3 The keypad will give 3 beeps and the panel will be in Installer Program mode Program icon is flashing 4 Replace the 1 link or seal the lid tamper 5 Program the panel as required Note 1 The panel will not exit program mode unless User Code 1 P1E is programmed all other programming options are optional Note 2 If the J1 link is open or lid tamper unsealed when you exit program mode the tamper alarm will trigger Top mounting hole x2 Keyhole Board Clip Retainers x2 adjustable position side cable entry Square duct knockout HEATSINK INSTALLATION amp POWER UP PROCEDURES The control panel housing should be mounted in a location that is within a protected zone of
35. 3 Seconds P28E Siren Time Minutes P271E Single Trigger P272E Double Trigger P291E Siren Lockout P301E Excludable P310E ADMIN Area P311E AREA 1 P312E AREA 2 P313E AREA 3 P321E MONITOR 1 P50E Client Code P51E Telephone Number 1 P52E Telephone Number 2 P59E Required rings for auto answer P70E Time before first Test Call P71E Test Call interval P97E Duress prefix digit Mapping zones to OUTPUT GROUP P322E MONITOR 2 P35xxE Armed state P36xxE Disarmed state P37xxE Monitor Mode P38xxE 24hr NESS D24 CONTROL PANEL INSTALLER MANUAL INSTALLATION RECORD User Codes PIE Usercode 1 master P Usercoee _ PF Usercodes PE Usercoes P Usercodes PoE pre usercode7 PBE _ PE Pi Usercodeto PE Umen PigE Usercodet2 Pie Uere L PME Usercodets 1 PE usco PIE usercodete ws PME POE Uere POE usercodezo PME usercodezt sss POPE usercode2e PME PE usercode2s POE usercode26 Poze usercodea7 POE usercode2s POE usercode2a Liv LILLL MASTER CODE RADIO KEY NESS D24 CONTROL PANEL INSTALLER MANUAL
36. 66E Select option E P67E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 60 minutes TO PROGRAM P67E time E Select 0 255 minutes RELATED OPTIONS P41E Mapping power alarms page 23 DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT MULTIPLE ALARM REPORTING RESTORALS REPORTING Disable reporting multiple zone alarms Enable reporting multiple zone alarms Send Restorals after Siren Time Send Restorals on Disarm Send Restorals immediately Do not send Restorals MULTIPLE ALARM REPORTING By default the panel will report zone alarms once per arming cycle P65E 1E and 2E will toggle the selection of single hit and multibreak reporting RESTORALS REPORTING These options apply only to zone alarms All other alarm types send Restorals when they happen except for Duress Panic Access Code and Medical for which a Restoral is never sent P66E 1E SEND RESTORALS AFTER SIREN TIME The Restoral is sent when Siren Time P28E has expired and the input has resealed P66E 2E SEND RESTORALS ON DISARM The Restoral is sent when the panel is next Disarmed provided the input has resealed P66E 3E SEND RESTORALS IMMEDIATELY The Restoral is sent immediately the input has resealed P66E 4E DO NOT SEND RESTORALS This option disables the reporting of zone Restorals OPTION No DESCRIPTION DEFAULT P67E Mains Fail reporting delay MAINS FAIL REPORTING DEL
37. AY This option sets the time in minutes for reporting of Mains power failure to be delayed This prevents the unecessary reporting of brief power interruptions The delay time can be programmed from 0 255 minutes Mains Power Failure is enabled and configured as an alarm by the related option P41xxE 1E 32 NESS D24 CONTROL PANEL INSTALLER MANUAL OPTION No DESCRIPTION D PROG DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT P68E Zone reporting Abort Delay 23 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Lee IIIILILLLLLLLLLLLLILLLLLLL P68E P69E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT P68E 30 seconds P69E no zones TO PROGRAM P68E time E Enter 0 100 seconds or 101 220 for 1 120 minutes P69E zone E zone E etc P70E P71E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Time before first test call 168 hours Test call interval 0 disabled TO PROGRAM P70E time E 0 255 hours P71E time E 0 255 hours NESS D24 CONTROL PANEL INSTALLER MANUAL ZONE REPORTING ABORT DELAY Any zone can be programmed for abort operation which means the zone must remain unsealed for the specified time before it is recognised as an alarm P68E ABORT DELAY TIME There are two time ranges Enter a value of 0 100 for 0 100 seconds Enter a value of 101 220 for 1 to 120 minutes P69E ABORT DELAY ZON
38. CE Press P84E Lights 1 8 will show which Radio Devices are currently programmed Press 1E 8E Press the Radio Device number followed by E NESS D24 CONTROL PANEL INSTALLER MANUAL This page is intentionally blank 38 NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0 hours disabled TO PROGRAM P86E 0 48 hours E RELATED OPTIONS P40xxE 7E To map the Medical Alarm to an Output Group Default is Output Group 30 Sonalert dialler See page 23 Medical Alarm Operation page 45 NESS RADIO OPTION No DESCRIPTION DEFAULT Pe3E Medical Delay MEDICAL DELAY Any 24 hour zone or Key switch input or Panic input may be used to control Medical alarm by assigning the chosen input to Output Group 16 A Instant Medical Alarm Immediately sound the sirens and send a Medical Alarm report to the Central Monitoring Station The Medical Alarm Delay must be set at zero hours B Inactivity Medical Alarm The Medical Alarm is reported if the Medical Alarm button is NOT pressed within the pre programmed Medical Alarm Delay The Medical Alarm Delay can be set between 1 and 48 hours INSTANT MEDICAL ALARM OPERATION 1 If the Medical Alarm Delay is not being used simply press the designated Medical Alarm button 2 f the Medical Alarm Delay is being used an instant Medical Alarm can be sent by pressing the button twice within 12 seconds On the first
39. DEFAULT OPTION DESCRIPTION DEFAULT E War PE s AUDIBLE Pulse reporting format 28 ALTERNATE CLIENT CODES Used when P60E is ON AUDIBLE DIMF reporting format P750E ADMIN Area Client Code 0000 35 CONTACT ID reporting format ON P751E AREA Client Code 0000 Auto Dialling Pulse amp DTMF ON 29 P752E AREA 1 Client Code 0000 Pulse dialling always P753E AREA 1 Client Code 0000 DTMF dialling always CREATE INSTALLER DEFINED OUTPUT GROUPS METHOD 2 i dc O N e P80 uuE yyE Installer defined Output Groups 1 15 Outputs 1 10 25 P81 uuE yyE Installer defined Output Groups 1 15 Outputs 11 16 3E Repeat to Telephone number 2 5E Enable remote Arm AREA 2 P831E PROGRAM Radio Keys Select Radio Key 1E 8E 37 6E Enable remote Arm AREA PB3E CLEAR Radio Keys Select Radio Key 1E 8E PE ENG OE eee P841E PROGRAM Radio Devices Select Radio Device 1E 8E Enable remote Disarm ALL AREAS P84E CLEAR Radio Devices Select Radio Device 1E 8E PE Required Rings for auto answer PB5E not used asss 1 Enable Open Close reports 30 P86E not used 2 Send ADMIN Area O C reports only P93E Medical Delay 0 hrs disabled 3E PME General Purpose Timer delay 0 sec disabled 40 Disable Open Close reports General Purpose Timer duration 0 sec disabled PEE Map Zones to Contact ID channels
40. E to exit the Memory menu Example How to view Memory and the types of events that might be shown Panel is Disarmed All zones are sealed Most recent event Zone 2 alarm Next most recent event Panel was Armed Next most recent event Mains power failure Press CVIEW2 moe etc Up to 50 events in memory Press E to exit Memory mode OPERATION EXCLUDING ZONES Zones and other inputs can be Excluded so that it does not generate alarms EXCLUDE is a method of temporarily disabling an input When zones have been Excluded the EXCLUDE icon flashes continuously while the panel is Disarmed and also when Armed Zones can only be Excluded when the panel is Disarmed Zone Exclude is not permanent Excluded zones are automatically INCLUDED next time the panel is Disarmed Zones can be manually included by the same method as Excluding In Exclude mode simply use the NUMBER E sequence to turn OFF the zone lights to be Included TO ENTER EXCLUDE MODE Press CODE E 0r CE If Shortcut Exclude is enabled TO EXCLUDE ZONES and will be on Press ZONE NUMBER E ZONE NUMBER E ete EXCLUDE ZONE The selected Zone numbers will turn on TO EXCLUDE TAMPER ALARMS Press T will be on TAMPER NUMBER elc EXCLUDE TAMPER The selected Tamper numbers will turn on TO EXCLUDE SYSTEM ALARMS Press 3 E and LS will be on
41. EAR Radio Devices 1 8 Select 1E 8E Select 1E 8E The optional 100 200 Ness Radio Interface is required for radio operation Program Radio Devices 1 8 RADIO KEY PROGRAMMING P83E P831E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No Radio Keys programmed NOTES The 8 Radio Codes operate independently they do not replace any keypad codes Radio Key programming is done by learning the code by radio If a Radio Key is lost or misplaced its use can be prevented by clearing that Radio Code using the keypad Radio Keys are allocated to User Codes 1 8 so that Open Close reports are identified by user number when the control panel is central Station monitored If Open Close reports are enabled RELATED OPTIONS P82E 3E Enable Radio Interface P34E 2E Enable Siren Chirps P84E P841E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No Radio Devices programmed NOTES Radio Device programming is done by learning the code by radio If a Radio Device is lost or misplaced it s use can be prevented by clearing that Radio Code using the keypad The device s ENCR link if fitted must be off This applies to the 100 663 Radio PIR and the 100 662 Radio Reed Sw RELATED OPTIONS P82E 3E Enable Radio Interface A total of eight Ness 100 664 Radio Keys can be programmed The Radio Keys operate in conjunction with D24 User Codes 1 to 8 and if monitored
42. ES Selects the zones which will have Abort Delay Time Press P69E zone number E zone number E etc up to 24 zones OPTION No DESCRIPTION DEFAULT P70E Time before first test call 168 hours P71E Test call interval 0 disabled TEST CALLS The D24 can be programmed to send periodic test calls to the Central Station P70E TIME BEFORE FIRST TEST CALL This option is used to set the preferred time for Test Calls Programmable from 0 255 hours Enter a value between and 255 Examples A New Installation Set the time before the first test call E g If you are programming the panel at 5pm and you want test calls to be sent at 1am Enter P70E 8E 5pm 8hrs 1am B Existing Installation To reset the time that test calls are sent E g Our example panel is sending test calls at 1am and you want to change it to 2am If you are programming the panel at 3pm enter 7 11E 8pm 11hrs 2am P71E TEST CALL INTERVAL Sets the time between test calls Commonly set for 168 hours 7 days ask your central station Programmable from 0 255 hours Enter a value between 0 and 255 A value of 0 zero disables test calls factory default Test Call times commence on exit from installer program mode P72E P73E P74E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Easycall disabled TO PROGRAM P72E 1E toggles the option ON and OFF P73E digits E Up to 15 digits to dial P74E digits E
43. Handover zones P23E Secondary delay zones P271E Single trigger zones Security delay zones N ON ON ON ON ON ON ON ON ON Entry Delay zones TE ss ON BENE _ ON ON ON Ty EMEN ON ON ON s ON ON ON ON ON ON ON ON ON ON on fon fonon ON ON PzmE pwnesgerzs ll Factory default settings shown ZONE ASSIGNMENT Each zone can be assigned with attributes which determine how the zone will be used P19E Security Delay can be assigned to zones already assigned to more than one Area Common Area Zones When a Common Area Zone is assigned as a Security Delay Zone the zone is Armed as soon as any Area it belongs to is Armed Unlike normal Common Area Zones which are Armed only when all assigned Areas are Armed P20E Instant zones do not have Entry Delay P21E Entry Delay Zones operate only in the Armed state These zones will activate the Entry Delay Timer P17E when they are triggered If the panel is not Disarmed before the expiry of the Entry Delay Timer the programmed alarm outputs will be activated P22E Handover zones are delayed only if entry is made through an Entry Delay zone first If a Handover zone is triggered first the zone behaves as an instant zone Normally the point of entry zone should be Delay zone with any other zones in the entry path programmed as Handover zones P23E Secondary Delay
44. NOWN N O rN N O rN N O rN N NONNOWN NON NONI 12V 7Ah Battery TAMPER Battery cradle Document holder Rear Tamper Switch Housing lid bolts x2 T Bottom mounting hole x2 Slotted Power Board Screwed to bottom of base Lid Tamper Switch Bolt Circlip Speed nut Bolt post Lid Tamper switch Lid Base Rear Tamper Switch NESS D24 CONTROL PANEL INSTALLER MANUAL lt T z Q lt O m lt lt D 24 DIALLER SECURITY ALARM PANEL eg eDed youmMsAey eui se 1ndui A3M e qeue oi 3L 300rvg nejep Aq 1ndur Jupz eui s 3ndui AJM x AHS LIVE d MOVva8 JHL OL 1995010 SIHL jueujdinbe jeujo pue sJoi2ejep JO sindino Oq AZL eidainiw eui pjeoq eui Buijejsur 15015 GNA SIHI yoq puey dp pij xog qe 1691 pal ddns peiddns SQV31 4 AO Yea OL S3H91IMS H3dNV1 191208 9 0 1290007 payddns qv313NOHd3131 er 201 sped ay e uinulel m tI3dINV 1 5 8 payjddns NALSI1 199 001 GVdAIy 491 Sen w 0 U91SI 0 Jayeads 19 19 0 YM dn J A0d 39vJu31NI 0I VH SS3N WYO 8 199000 6 5 aduwe 55 u0123NNO2 ef SOILSONSVIC 9 5 jeuou paeas 6 WWH90Hd 9
45. RAM eda access to ALL program options Note The panel will remain in Installer P INSTALLER CODE E Program Mode indefinitely Factory default Installer Code 000000 USER PROGRAM MODE EE USER PROGRAM Mode User Program Mode allows the PROGRAM PROGRAM LIGHT IS ON owner to program All User Codes Entry and Exit times P MASTER CODE Note The panel will automatically drop out of User Program Mode to Operating Mode if no keypad buttons are pressed for 1 minute NORMAL OPERATING Mode PROGRAM LIGHT IS OFF HOW TO ENTER PROGRAM MODE FROM POWER UP 1 Power up with the J1 link OFF The J1 link must be ON in operating mode Or if using J1 for housing tamper the tamper switch es must be sealed 3 USING THE KEYPAD NC 8 69 The panel must Disarmed 959 1 Press P MASTER CODE The keypad will respond with 3 beeps J This is User Program Mode PROGRAM light is ON 2 Then press INSTALLER CODE E The keypad will respond with 3 beeps J This is Installer Program Mode PROGRAM light is FLASHING HOW TO EXIT PROGRAM MODE THE PANEL WILL NOT EXIT PROGRAM MODE UNLESS USER CODE 1 P1E IS This is Operating Mode PROGRAM light is OFF PROGRAMMED KEY SEQUENCE IN PROGRAM MODE Selects a program The current value Enter new option address is displayed data C GXOOQOOO JJ mores ddd 2 4 digit Option No 3beeps Current value
46. Up to 15 digits to dial NOTES The digits programmed P73E and P74E are not dependant on Open Close reports If Open Close reports are disabled the digits will be dialled after Arming Disarming DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT Enable Easycall feature OFF Digits to dial after Opening 0 disabled Digits to dial after Closing 0 disabled EASYCALL DIALLING The D24 can dial pre programmed digits after opening and closing reports This can be used to automatically enable and disable Easycall telephone diversion of the premises telephone every time the panel is Armed and Disarmed P72E ENABLE EASYCALL FEATURE Press P72E 1E to enable disable the option The option is off by default P73E DIGITS TO DIAL AFTER OPENING Press P73E digits E Normally you would want to disable Easycall diversion after opening ie the client is now at home Example P Z 3 E ronron 2 1 Cromor E The digits 21 will be dialled after the panel has sent the Opening Report if enabled P74E DIGITS TO DIAL AFTER CLOSING Press P74E digits E Program the telephone number to divert to Example P 7 4 E 2 1 telephone number E The digits 21 telephone number will be dialled after the panel has sent the Closing Report if enabled SPECIAL CHARACTERS FOR TELEPHONE NUMBERS SPECIAL CHARACTERS Applies to all telephone Numbers Pauses star or hash VF digits
47. an send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone s which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system Central Station Monitoring is highly recommended and is the most effective method of monitoring your alarm system Installers are welcome to contact Ness for further information about monitoring AUDIBLE MONITORING P54E 1E enabled While Central Station Monitoring is recommended the D24 can also send audible alarm reports to any DIMF capable telephone REPORTING SEQUENCE When triggered by an alarm event the D24 will call the Primary Telephone Number P51E and then commence the audible message the audible message will continue to repeat for 45 seconds or until it is kissed off by a DIMF tone If there is more than one alarm message to transmit then after it has received the Kiss off Acknowledge tone it will commence transmission of the next message The D24 should continue to do this until all alarm messages are transmitted and Kissed off ACKNOWLEDGE TONE The person receiving the call can then acknowledge the alarm by pressing the 4 key on their telephone Press the 4 key for at least 2 seconds during pauses in the audible message 50 NESS D24 CONTROL PANEL INSTALLER MANUAL AUDIBLE FEEDBACK J J 3 BEEPS e The User Code is valid
48. are reported as User Codes 1 8 to the central station O TO PROGRAM Press P831E then select a Radio Key to program 1E 8E On the Radio Key to be programmed press and hold the PANIC button for 8 seconds The MEMORY light will flash during the 8 second Learn transmission If the Radio Key is accepted the MEMORY light will turn on steady and 3 beeps will sound f the MEMORY light does not flash the Radio Key is already programmed and must be cleared before it can be programmed again TO CLEAR DELETE A RADIO KEY Press P83E Lights 1 8 will show which Radio Keys are currently programmed Press 1E 8E Press the Radio Key number followed by E RADIO DEVICE PROGRAMMING A total of eight Ness Radio Devices can be programmed A Radio Device is any type of Ness transmitter including Radio PIR Radio Reed Switches Radio Smoke Detector TO PROGRAM Press P841E then select a Radio Device to program 1E 8E Trigger the Radio Device f the Radio Device is accepted the MEMORY light will turn on steady and 3 beeps will sound f the MEMORY light does not flash the Radio Device is already programmed and must be cleared before it can be programmed again e When the device has been programmed remove its battery to prevent it from transmitting while you program the next device Remember to replace all the batteries when finished programming TO CLEAR DELETE A RADIO DEVI
49. ation to 60 minutes P 95 E 160 E 3 Build up an Output Group which includes the Relay for the Timer to turn on We will create Output Group 1 for the example P 801 4 Program the timer to drive this output P 421 1 Assign your zone inputs to trigger a monitor output which includes the timer selected to do this you will need to build another Output Group for this example we will create Output Group 2 Build the Output Group P802E1E2bESGEA4EP812E1EGEA4E Assign Monitor Zones 1 6 to output 2 P372bE1E2ESEA4ESEGE OPTION No DESCRIPTION DEFAULT P99E Program Installer Code 000000 PROGRAMMING THE INSTALLER CODE This option programs the Installer Code Factory default is 000000 NESS 024 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 2 retries TO PROGRAM P96E retries E 0 9 RELATED OPTIONS P40xxE 8E To map User Code Alarm to an Output Group See page 23 P97E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 9 TO PROGRAM P97E duress prefix digit E 0 9 RELATED OPTIONS P40xxE 5E To map the Duress Alarm to an Output Group See page 23 P98xE PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT as per Options Summary TO PROGRAM P 98x E PROGRAM OPTIONS SUMMARY Pages 54 55 NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAMMING OPTION No DESCRIPTION DEFAULT CODE RETRY LIMIT The n
50. ay have smoke detectors connected to 24 hour Fire inputs Fire inputs if enabled are indicated by the Fire icon on the keypad Any zone can be become a Fire input by mapping it to Output Group 26 NESS D24 CONTROL PANEL INSTALLER MANUAL 48 DEFAULT VIEW The display always shows the zone menu by default It will automatically revert back to the ZONE menu after eight seconds if left in any other view menu ZONE This is the normal display while disarmed with no outstanding alarms The ZONE icon is on as well as any number 1 to 24 if zones are being unsealed 12 3 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ZONE Zone numbers will be on only if there are unsealed zones or alarmed zones to view TAMPER Tamper numbers will be on only if there are Tamper alarms to view N SYSTEM System numbers will be on only if there are System alarms to view POWER Power numbers will be on only if there are Power alarms to view OPERATION VIEW MENU The VIEW menu can be used at any time to display the status of Zone Tamper System and Power inputs The status of these inputs can be displayed live as it happens or as a previous event in Memory mode TO VIEW A CURRENT ALARM Press CviEw2 the MEMORY icon will be on and one of the system icons N D along with a number to ZONE TAMPER SYSTEM POWER indicate which alarm is present If there is no current outstanding alarm
51. can be used to disable the dialler while retaining all dialler programming P82E 3E ENABLE RADIO INTERFACE Off by default Enables the optional 100 200 Radio Interface if used P82E 4E ENABLE OUTPUT EXPANDER Off by default Enables the optional 100 011 Output Expander if used The optional D24 Output Expander connects to the D24 control panel and provides 35 open collector outputs and 1 relay output The outputs can be used to drive mimic displays provide additional outputs on alarm and various other custom purposes The Output Expander board interfaces with the D24 by three wire serial connection The board is designed to fit inside the D24 control panel housing For full details of Output Expander operation see page 52 NESS RADIO NESS RADIO INTERFACE NOTES The Ness Radio Interface 100 200 is the optional radio receiver required to e The Ness Radio Interface is normally installed enable all radio functions inside the control panel box In cases where radio reception needs to be Connection to the control panel is via a 4 wire loom and plug supplied with the improved the Radio Interface can be Ness Radio Interface installed up to 50 metres away from the control panel Use 14 0 20 cable If the Radio Interface must be installed inside a metal enclosure the antenna wire should NESS D24 NESS RADIO INTERFACE protrude outside the enclosure CONTROL PANEL Part No 100 200 For best p
52. con will turn on Each test zone will now on going unsealed cause its zone indicator to fast flash and the Reset output to give a 2 second burst To cancel the walk test press the E button To restart the walk test press 1E The icon will resume flashing The TEST previously selected test zones will be on P45E 2E AUTOMATIC ZONE TEST This test can identify potentially faulty detection devices by alerting the user to zones which have not unsealed during the past 20 Arm and Disarm cycles If selected the test runs during the normal operation of the panel If any non 24hr zone s does not unseal during 20 Arming cycles the D24 will alert the user by turning on the icon You can view the offending Zone s by pressing VIEW 7 The offending zone s icons will be ON To clear the Zone Test label unseal the offending zone s while still in the VIEW 7 mode This will result in the steady zone icon changing to a fast flash This will verify whether the zone is functioning correctly or not To cancel the display press the E button If the icon remains on press VIEW 7 then E lt CENTRAL STATION MONITORING MONITORING STATION MONITORED PREMISES TELEPHONE LINE AUDIBLE MONITORING MONITORED PREMISES TELEPHONE LINE AUDIBLE MONITORING REPORTING FORMAT TABLE MONITORING CENTRAL STATION MONITORING P54E 3E enabled Default The Ness D24 control panel has an on board digital dialler which c
53. d to drive mimic displays provide additional outputs on alarm and various other custom purposes The Output Expander board interfaces with the D24 by three wire serial connection The board is designed to fit inside the D24 control panel housing PROGRAMMING To become active the Output Expander must be enabled by the D24 programming option P82E 4E P82E 4E toggles the option ON and OFF P82E 4E OFF Output Expander is DISABLED P82E 4E ON Output Expander is ENABLED CONNECTION TO THE D24 N C 5 ADMIN ARM MEDIC AM 12V FUSED SAT RADIO LOW BAT D24 OUTPUT EXPANDER N N N N N N N N N N N N N N N N N N N N N N N ON 52 NESS D24 CONTROL PANEL INSTALLER MANUAL Se NOTES NESS D24 CONTROL PANEL INSTALLER MANUAL INEZ D 24 OPTION DESCRIPTION DEFAULT PAGE User Code tae Coa _ usercoes p baro Um Uets usar ueten ecu SEMIS TES S EMIT INE uem _ Usercoie20 Umen uecen _ etn C EI TN User Code 30 15 P170E Entry Delay Time 17201891 P171E Entry Delay Time for AREA 1 PIBE _ Exit Delay Time 60 Sec PIBIE Ext Delay Time for AREA1 60 Sec P182E Ext Delay Time fo
54. dable ON ON Control Panel Tamper ON ON Zone input Tamper ON ON Radio Interface Tamper ON SYSTEM ALARMS Keyswitch Panic P293E Lockout P303E Excludable Dialler line fault Keypad connection fault Control Panel fault Duress alarm Panic alarm Medical alarm User Code alarm Access to Installer Program mode POWER ALARMS Mains power failure P294E Lockout P304E Excludable ON Backup Battery low DC supply failed Zone reference supply failed Radio Device battery low Radio Key battery low SIREN LOCKOUT Select the zones or alarms which will have Siren Lockout Siren Lockout zones alarms will sound the Siren output once only during any Armed period but further alarms will trigger the Reset and Strobe output if programmed P291E Siren Lockout Zones P292E Siren Lockout Tamper Alarms P293E Siren Lockout System Alarms P294E Siren Lockout Power Alarms EXCLUDABLE ALARMS Select the zones or alarms which can be Excluded P301E Excludable Zones P302E Excludable Tamper Alarms P303E Excludable System Alarms P304E Excludable Power Alarms 18 NESS D24 CONTROL PANEL INSTALLER MANUAL OPTION No P310E DESCRIPTION Assign zones to ADMIN AREA PROGRAMMING AREA PARTITIONING DEFINITION Area Partitioning allows the 24 zones to be split into 4 partitions Areas 1 2 3 and Administrator Admin area By default all zone
55. e read back P17E P173E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P Option No E New time E EXAMPLE To program 30 sec Global Entry Delay P17E 30E NOTES All timers are programmable from 1 99 seconds P18E P183E PROGRAM MODE LEVEL User Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P Option No E New time E EXAMPLE To program 55 sec Global Exit Delay P18E 55E NOTES All timers are programmable from 1 99 seconds PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 10 Minutes TO PROGRAM P Option No E New time E EXAMPLE To program 5 minute Siren Time P28E 5E NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAMMING OPTION No DESCRIPTION DEFAULT Entry Delay Time 20 Seconds 20 Seconds 20 Seconds Entry Delay Time for zones in multiple areas Entry Delay Time for AREA 1 Entry Delay Time for AREA 2 Entry Delay Time for AREA 3 Exit Delay Time Exit Delay Time for AREA 1 Exit Delay Time for AREA 2 Exit Delay Time for AREA 3 Siren Reset Time 20 Seconds 20 Seconds 60 Seconds 60 Seconds 60 Seconds 60 Seconds 10 Minutes ENTRY DELAY TIMERS The Entry Delay Time is the time given to Disarm the panel after an Entry Delay zone is unsecured P17E This is the Global Entry Delay Time Any value programmed at this option also changes all other Entry Delay Ti
56. eedback when programming TO PROGRAM P43 Select an Output Group 1 15 E Select outputs 1 16 E EXAMPLE To build Output Group 1 to include the outputs Output 1 Siren A Output 3 Reset Output 12 Dialler P43 1E 1E 12E METHOD 2 Method 2 provides a visual display of the outputs added to the selected Output Group but uses 2 separate program options to add the 16 possible outputs to an Output Group P80 uuE yyE uu Output Group 1 15 yy Output 1 10 select 1E 10E P81 uuE yyE uu Output Group 1 15 yy Output 9 16 select 1E 6E TO PROGRAM P80 Select an Output Group 1 15 E Select outputs 1 10 E P81 Select an Output Group 1 15 E Select outputs 9 16 E EXAMPLE To build Output Group 1 to include the outputs Siren A Output 1 Reset Output 3 Dialler Output 12 P80 1E 1E 3E P81 1E 2E D PROG OPTION No DESCRIPTION DIALLER PROGRAMMING 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT no zones selected TO PROGRAM P441E Zone No E Turns the option ON or OFF for each zone RELATED OPTIONS P19E Security Delay page 16 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P45E Select option E NOTES e Zone icons during P45E 1E test OFF zone not selected for test ON zone not triggered FAST FLASH zone triggered CAUTION Automatic Z
57. ephone number 5 times P57E 3E REPEAT TO PHONE NO2 Report to the Primary telephone number and repeat to the Secondary telephone number DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT REMOTE ACCESS Remote command call back upload 1 OPTIONS Remote command call back upload 2 Enable remote ADMIN Arming Enable remote AREA 1 Arming Enable remote AREA 2 Arming Enable remote AREA 3 Arming Enable remote toggle AUX1 amp AUX2 Enable remote Disarm all Areas Required Rings to Auto answer OPEN CLOSE Enable Open Close reports REPORTING OPTIONS Send only ADMIN AREA O C reports Send O C reports with Client codes as per P75xxE Disable Open Close reports PROGRAM MODE LEVEL These options will enable the D24 to auto answer an incoming call and carry out Installer Remote by PC the functions as described FACTORY DEFAULT See REMOTE OPERATION BY TELEPHONE page 51 none TO PROGRAM REMOTE ACCESS OPTIONS P58E Select option E 2 59 REQUIRED RINGS AUTO ANSWER PROGRAM MODE LEVEL This option sets the number of double rings before the D24 enables auto Installer Remote by PC answering of the next call FACTORY DEFAULT The number of rings can be set from 0 to 20 rings 1 ring is recommended for fax 1 ring defeat to work correctly TO PROGRAM FAX DEFEAT P59E required rings E Select 0 to 20 rings Fax Defeat works as follows 1 Phone the D24 telephone
58. er 10 seconds The Timer should only be used to operate on unused outputs wherever possible to save confusion PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 000000 TO PROGRAM P99E new code E new code E 3 6 digits PROGRAMMING OPTION No DESCRIPTION DEFAULT P94E General Purpose Timer Delay 0 sec P95E General Purpose Timer Duration 0 sec GENERAL PURPOSE TIMER The General Purpose Timer GPT is a versatile extra timer which can be used along with all the other standard features of the D24 to turn on an extra output for a pre determined period of time with an optional pre alarm delay The GPT can be programmed to trigger from any alarm input of the D24 whether that input is used for other functions or not and can turn on for a maximum 120 minutes with a maximum pre alarm delay of 120 minutes P94E TIMER DELAY This is the time from the input on to the start of the output pulse time E There are two time ranges Enter a value of 0 100 for 0 100 seconds Enter a value of 101 220 for 1 to 120 minutes P95E TIMER DURATION Duration the Timer stays on P95E time E There are two time ranges Enter a value of 0 100 for 0 100 seconds Enter a value of 101 220 for 1 to 120 minutes EXAMPLE To set up the timer to turn on the Relay for 1 hour with a pre delay of 30 seconds when a Monitor Zone triggers 1 Program the timer delay to 30 seconds P 94 E 30 E 2 Program the timer dur
59. erformance the antenna wire J3 CONNECTOR should be kept straight and not coiled shortened or extended RADIO Je m EE E RED DEN WHITE DATA 5 5 BLUE RSSI 34 2 8 BLACK LE zog E J3 4 RADIO DEVICES Signal types transmitted g SIGNAL RADIO KEY RADIOKEY RADIO KEYPAD RADIO RADIO SMOKE TYPE PENDANT 3 BUTTON REED SWITCH DETECTOR Arming ALARM ON button by User ID RESTORAL OFF button Disarming by User ID PANIC PANIC button PANIC button PANIC button LOW BATT yes yes SUPERVISION RADIO DEVICES OPERATION ALARM Any Ness Radio Device can operate on any zone 1 8 as programmed by P841E The hardwired zones 1 8 continue to operate in parallel TAMPER Radio Device Tamper is transmitted by the 100 662 Radio Reed Switch This appears as Tamper Alarm number 5 RELATED OPTIONS LOW BATTERY REPORT Low battery alarms from radio devices are displayed P41xxE 9E amp OE to map low battery alarms to by the keypad as Power Alarm 9 and Power Alarm 0 Output Groups Page 23 VIEW 9 Displays low battery alarms from Radio Devices 1 8 P64E 9E amp OE to map low battery alarms to VIEW 0 Displays low battery alarms from Radio Keys 1 8 Contact ID channels Page 31 NESS D24 CONTROL PANEL INSTALLER MANUAL NESS RADIO OPTION No DESCRIPTION OPTION CLEAR Radio Keys 1 8 Select 1E 8E Program Radio Keys 1 8 Select 1E 8E CL
60. f Telephone Commands 7 Press x st to finish This tells the D24 to hang up Also hang up your telephone CONNECTION The Output Expander is wired to the D24 using only 3 wires as shown below AUX on the D24 is the serial data connection to the Output Expander When the Output Expander is connected and enabled the function of the D24 AUX output is provided by the AUX1 output on the Output Expander CONNECTION TABLE OUTPUT EXPANDER 12V AUX IN OUTPUTS The open collector outputs can sink 100mA each and can be safely connected together for OR operation The relay output has changeover N O amp N C contacts rated at 2A The maximum current load available from the fused 12V DC output is 1 5 Amp OUTPUTS OPERATION All zone and emergency outputs latch on alarm and are cleared by Arming Disarming or a Code entry All other outputs follow their input states See the Outputs Operation Table OUTPUTS OPERATION TABLE OPERATION OUTPUTS Zone alarms 1 24 Latching outputs Duress Keypad Panic Cleared on Arming Disarming or Code Entry Panic Medical Tamper Radio Low Battery Admin Area Armed Areas 1 3 Armed Follow input state Mains Fail Low Battery RELAY Follows trigger state D24 OUTPUT EXPANDER The optional D24 Output Expander connects to the D24 control panel to provide 35 open collector outputs and 1 relay output The outputs can be use
61. her codes can be programmed as Master Codes if needed TO PROGRAM CE CODE E CODE The 1 2 3 icons will be FLASHING ARM AREA1 AREA2 AREA3 EXAMPLES Program User Code 1 the permanent Master Code to be 1234 P1E 1234E 1234E Program User Code 2 to be 789 and an Ordinary Code P2E 789E 789E Program User Code 3 to be 5678 and an Area 1 Code P3E 1E 5678E 5678E Program User Code 4 to be 222 and an Area 2 Code P4E 2E 222E 222E Program User Code 5 to be 8990 and an Area 3 Code P5E 3E 8990E 8990E PROGRAMMING FEEDBACK When programming user codes the existing code and then the new code is read back by flashing the numeric keypad icons 0 0 1 Press P Option No E the existing code is displayed by the keypad 2 Enter the new code 3 to 6 digits New code E 3 Enter the new code again New code E the new code will be displayed NOTE After step 1 the new code can be entered immediately without waiting for the display to finish the read back 14 NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAMMING FEEDBACK When programming timers the existing time and then the new time is read back by flashing the numeric keypad icons 0 9 1 Press P Option No E the existing time is displayed by the keypad 2 Enter the new time New time E the new time will be displayed NOTE The new time can be entered immediately without waiting for the display to finish th
62. his assumes no more than 500 is being drawn from the 12V device output NESS D24 CONTROL PANEL INSTALLER MANUAL Em OUTPUTS AUX The AUX output is a programmable Open Collector output suitable for LEDs Relays etc This output can sink a total of 50mA 12V 0V OUTPUT x3 A regulated 13 8 VDC output is available to power detectors and other equipment This output is available from three sets of terminals marked 12V and OV The output is protected by an Automatic Reset fuse The three sets of 12V outputs can be used to power 1 The Output Expander board optional 2 The D24 Power Board supplied and all equipment off the Power Board 3 The D24 keypad supplied A maximum load 500mA in total can be connected to these terminals RELAY The relay is a programmable output providing a set a dry changeover contacts N C COM N O with a contact rating of 2A 24V RESET A 12V DC output for connecting Ness Sirens piezo sirens or relays etc This output will reset at the end of Siren Reset Time P28E or whenever the panel is reset A maximum of 3 x 12V piezo Sirens Ness Part No NOI240 NOI 230 100 238 or 2 X Ness Piezo Part No 100 172 can be connected to this output The output is protected by an Automatic Reset fuse STROBE A latched 12VDC output for connecting strobe lights This output will latch on in the event of an alarm condition and stay on until the panel is reset A maximum of 2 x 1 Watt S
63. ially Arming and Disarming There are 30 User Codes and each can be 3 to 6 digits long User Code 1 is always a MASTER CODE User Codes 2 to 30 can be programmed as one of the types ORDINARY ADMINISTRATOR AREA or MASTER When programming codes the User Code type is indicated by the icons ARM AREA1 AREA2 lf User Code 1 was used to enter Program Mode the digits of any existing codes will be displayed when programming a User Code ORDINARY CODE An Ordinary Code is for systems configured without Areas Allows full access to the panel except for entry to Program Mode TO PROGRAM NN E CODE CODE The 1 2 3 icons will be ON ARM AREA1 AREA2 AREA3 ADMINISTRATOR CODE An Administrator Code is able to Arm and Disarm all Areas of a Partitioned system but it is not allowed entry to Program Mode Programming is the same as an ordinary code TO PROGRAM NN CODE CODE The 1 2 3 icons will be ON ARM AREA1 AREA2 AREA3 AREA CODE An Area Code is a code which only has access to the Area assigned to it TO PROGRAM NN AREA No CODE CODE 2 or 3 will be ON depending on Area No entered AREA 2 AREA 3 One of the icons Q or MASTER CODE A Master Code is able to Arm and Disarm all Areas of a Partitioned system and is allowed entry to Program Mode User Code 1 is always a Master Code but all ot
64. is disarmed P37xxE MONITOR MODE Assign zones to output groups to be triggered when the panel is in Monitor mode P37 Output Group 0 31 E Zone number E Zone number E etc Factory default setting is all zones mapped to output group 20 P3720E will show all 24 zones on P38xxE 24HR ZONES Create 24hr zones by mapping zones to output groups in this option P38 Output Group 0 31 E Zone number E Zone number E etc Factory default setting is all zones mapped to output group 0 P380E will show all 24 zones on This means that no zones are 24hr zones Note xx refers to the Output Group number see the Output Groups table on page 24 NESS 524 CONTROL PANEL INSTALLER MANUAL a PROGRAMMING DEFAULT OPTION No DESCRIPTION GROUP Map TAMPER ALARMS External Tamper 27 to output groups Control Panel Tamper 27 Zone input Tamper 27 Radio Interface Tamper 27 Map SYSTEM ALARMS Keyswitch Panic KEY input 22 to output groups Dialler line fault 24 Keypad connection fault 24 Control Panel fault 24 Duress alarm 29 Panic alarm 27 Medical alarm 30 User Code alarm 27 Access to Installer Program Mode 24 Map POWER ALARMS Mains power failure 30 to output groups Backup Battery low 30 DC supply failed 23 Zone reference supply failed 23 Radio Device battery low 30 Radio Key battery low 30 Map General Purpose Timer 0 GENERAL PURPOSE TIMER to output g
65. least sensitive setting Avoid using highest and lowest sensitivity they are provided as a guide to the upper and lower limits Ness NESSENSOR Vibration sensor ADJUSTMENT Part No VIB100 In addition to zone sensitivity adjustment the overall sensitivity of the Nesssensor C J can be adjusted by rotating the body of the Nesssensor within its bracket 51mm a ri The bracket must always be mounted horizontally and the arrow must point up for the required setting RED N C Vibration BLUE contacts YELLOW Tamper GREEN loop 350mm cable 4 36mm 2x 3mm holes 7 at 27mm spacing For efficient operation Nessensors must be attached to fixtures using screws not adhesive tape or silicone PROGRAMMING ra OPTION DESCRIPTION 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ten Loko ZONES on ono ooo oon on ov ow ow c eo onf onf ononon on on on ov P3O1E ExcludableZONES ON ON ON ON ON ON on ON PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P 29x E Zone No E Toggles the option ON and OFF PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P 30x E Alarm No E Toggles the option ON and OFF TAMPER ALARMS External Tamper P292E Lockout P302E Exclu
66. ler buffer SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded For maximum security you should return Disarm check the premises and then Arm again Continual warnings could mean that a detector is faulty and may have to be manually excluded AUTO EXCLUDE If the auto exclude option is disabled the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time ERROR BEEP WHEN DISARMING An error beep when attempting to Disarm may indicate Incorrect Code or the panel is already Disarmed or the panel is in Exclude mode OPERATION OPERATING MODES The Ness D24 will operate in one of the following modes ARMED The system is On and ready to detect intrusion 24 Hour Zones if configured are still active Area Partitioning means the panel can be split into three separate Areas which can be Armed and Disarmed independently of each other DISARMED The system is This is the normal mode when the premises are occupied Day Zones and 24 Hour Zones if configured are still active DAY Mode The system is Disarmed and a zone or zones have been setup to create an alarm when activated Often used as a doorway alert in a shop MONITOR Mode Allows the system to be partially Armed For example in a hou
67. mers P170E This is the Entry Delay timer for zones assigned to more than one area Any value programmed at this option also changes P17E P171E P172E P173E are not affected P171E P172E P173E Area 1 2 and 3 Entry Delay times can be individually programmed with different values EXIT DELAY TIME The Exit Delay Time is the time given to vacate the premises after the panel is Armed All zones except 24 hour zones are disabled during the Exit Delay Time P18E This is the Global Exit Delay Time Any value programmed at this option also changes all other Exit Delay Timers If different exit delays are required for each Area use P181E P183E P181E P182E P183E Area 1 2 and 3 Exit Delay Times can be individually programmed with different values SIREN RESET TIME The Siren Reset Time sets the duration of the Siren and Reset outputs Programmable from 1 99 minutes OPTION No DESCRIPTION PROGRAMMING n 4 5 6 7 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Instant zones selectable per zone SELECTION SELECTION GROUP Only one option is GROUP P19E P272E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO PROGRAM P Option No E Zone No E Turns the option ON for each zone selected NOTES Selecting a zone attribute will turn off any other attribute within the same Selection Group RELATED OPTIONS P441E Zones With No Exit Delay page 26 P22E
68. ning a zone ON in a sensitivity level turns the zone OFF in any other sensitivity level 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Only one option is selectable per zone 25 LOWEST SENSITIVITY P261E P268E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT no zones selected TO PROGRAM P 26x E Zone No E Turns the option ON for each zone selected NOTES e Zones are allocated to one sensitivity level at any one time Turning a zone ON ina sensitivity level turns the zone OFF in any other sensitivity level USING NESSENSORS Nessensors are sensitive to high frequencies and insensitive to low frequencies Therefore it is not necessary to apply much force to the protected Structure rather a very rapid succession of blows The sensitivity has been correctly adjusted when a single blow applied with a soft object e g by hand does not cause an alarm whereas a rapid series of blows using a metal object such as a screwdriver blade will cause an alarm NESS D24 CONTROL PANEL INSTALLER MANUAL Factory default settings shown VIBRATION SENSITIVITY P261E P268E Each zone has individually adjustable sensitivity for connection of Nessensor Vibration Sensors Vibration Sensitivity counts pulses at 20ms intervals for a time window of 600ms There are 8 levels of vibration sensitivity P261E is the most sensitive setting P268E is the
69. nnecting a maximum of 3 x 8 ohm horn speakers SIREN B Second siren output with the same specifications as SIREN A RESET 12V DC output for connecting Ness Sirens piezo sirens etc STROBE Latched 12VDC output for connecting strobe lights AUX 1 The AUX output is a programmable Open Collector output suitable for LEDs Relays etc 6 AUX 2 RELAY Dry changeover contacts N C COM N O with a contact rating of 2A 24V 7 SONALERT Beeps all keypads when activated 8 FIRE Fire indicator icon on all keypads 9 SIREN A BURST Siren A output burst for 2 seconds 10 RESET BURST Reset output burst for 1 second 11 Pre Alarm Sonalert e Sonalert beeps on all keypads when an input turns on Pre alarm time is equal to entry delay Siren A bursts at the end of Pre Alarm if panel reset has not cancelled it The sonalert is turned off upon panel reset 12 Reports alarms by dialler when the mapped input alarms 13 TIMER Programmable general purpose timer 14 ALARM STATE If selected alarm indicators fast flash when any input assigned to the output turns on The alarm clears only when the panel is reset by entering a code f not selected outputs follow the inputs and alarm indicators turn on steady when the input is on 15 SIREN TONE 1 16 SIREN TONE 2 E NESS D24 CONTROL PANEL INSTALLER MANUAL Method 1 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see table TO
70. nt code is a 4 digit number which identifies the panel to the central station P51E TELEPHONE NUMBER 1 The primary telephone number for reporting alarms to the central station P52E TELEPHONE NUMBER 2 The secondary telephone number for reporting alarms to the central station P53E TELEPHONE NUMBER 3 CALLBACK The callback telephone number is used by the panel when doing an upload download callback SPECIAL CHARACTERS FOR TELEPHONE NUMBERS SPECIAL CHARACTERS Applies to all telephone Numbers Pauses star or hash VF digits can be included in the dialling sequence by using the keys in the table below SPECIAL CHARACTER PAUSE 1 6sec Star Hash KEY ENTRY AREA Key ARM Key MONITOR Key INDICATION ON LCD DISPLAY 6 Flashing 2 Flashing 3 Flashing PROGRAMMING FEEDBACK When programming client codes and telephone numbers the existing digits and then the new digits are read back by flashing the numeric keypad icons 0 0 1 Press P Option No E the existing client code or phone number is displayed by the keypad 2 Enter the new client code or phone number New number E the new number will be displayed NOTE After step 1 the new number can be entered immediately without waiting for the display to finish the read back NESS D24 CONTROL PANEL INSTALLER MANUAL 27 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Contact ID format TO PROGRAM P54E Selec
71. number and listen for the required number of rings ring ring ring ring and then hang up 2 Call the number again within 60 seconds 3 The dialler will answer the very next incoming call on the first ring detected this may require one or two rings in practice If 60 seconds has expired before the next call the dialler will revert back to the count ring mode as above 60 OPEN CLOSE REPORTING OPTIONS PROGRAM MODE LEVEL P60E 1 ENABLE OPEN CLOSE REPORTS Installer Remote by PC P60E 2E SEND ONLY ADMIN AREA OPEN CLOSE REPORTS P60E 3E SEND O C REPORTS WITH CLIENT CODES AS PER P75XXE FACTORY DEFAULT I U i I 1 on Open Close reports enabled This option enables the reporting of Area open close reports using the Client numbers as programmed at options P751E P752E P753E TO PROGRAM P60E Select option E P60E 4E DISABLE OPEN CLOSE REPORTS When this option is enabled 1E automatically disables and vice versa NESS 024 CONTROL PANEL INSTALLER MANUAL P61E P64E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT see tables TO PROGRAM P61E Select zone E Select code E P62E Select alarm no E Select code E P63E Select alarm no E Select code E P64E Select alarm no E Select code E NESS D24 CONTROL PANEL INSTALLER MANUAL El D PROG DIALLER PROGRAMMING OPTION No DESCRIPTION ZONE Map ZONE ALARMS DEFAULT CHANNEL DEFAULT DEFAULT ZONE CHANNEL ZONE CHANNEL
72. o monitor perimeter zones doors and windows while you are at EXIT DELAY home The Exit Delay time applies to Monitor Your system may be programmed to give the choice of Arming two different mode Monitor areas Dual Monitor mode otherwise there is one Monitor area Single Monitor mode ARMING SINGLE MONITOR MODE Press Or E or icone Three beeps will sound and the MONITOR icon will flash constantly MONITOR ARMING DUAL MONITOR MODE Press 1 OF 2 OF 1 E or CuonrroR 2 E MONITOR 1 armed is indicated by the 1 icon flashing constantly AREA 1 MONITOR 2 armed is indicated by the 2 icon flashing constantly AREA 2 PANIC ALARM The keypad panic function may have been programmed to be either Audible Activates siren or buzzers or Silent If Central Station monitored sends a Panic report by dialler Panic reports are enabled P40xxE 6E Panic cannot be used while the panel is in Program Memory or Exclude mode Keypad Panic alarm is number 6 in the A view Press C D Press and hold for at least 1 second C 2 E If Two Button Keypad Operation is enabled D DURESS ALARM A DURESS alarm can be triggered to alert the Central Monitoring Station that IF DURESS ALARM IS USED the user is being forced to Disarm the panel against their will AVOID USER CODES THAT BEGIN WITH THE SAME NUMBER AS A DURESS DIGIT To Disarm and simultaneously send a DURESS alarm
73. one Test is often used to identify inactive zones on a system where regular zone activity is expected Automatic Zone Test will obviously alert you to zones which remain sealed for extended periods For example manhole cover reed switch Factory default settings shown ZONES WITH NO EXIT DELAY Select the zones which will not have exit delay Normally all zones are delayed during exit delay allowing the user to leave the premies through any zone s TO PROGRAM P 441 E Select zone E EXAMPLE To program zones 8 9 amp 10 to have no exit delay P441E 8E 9E 10E OPTION No DESCRIPTION DEFAULT TEST OPTIONS 1E Installation walk test mode 2E Enable Auto Zone Test TEST OPTIONS P45E 1E INSTALLATION WALK TEST MODE This test runs in installer program mode while P45E 1E is selected Outside of installer program mode the test is supended but the zone selection remains ON Installation Walk Test Mode is enabled To enter test mode press P45E 1E The icon will fast flash then press zone TEST number E zone number E etc Select or de select the zones to test As each zone is selected the corresponding zone icon will turn on Each test zone will now on going unsealed cause it s zone indicator to fast flash and the Reset output to give a 2 second burst To cancel the walk test press the E button To restart the walk test press 1E The icon will resume flashing The TEST previously selected test z
74. one input can help determine the wiring fault The zone input can be individually programmed for various alarm types including Instant Delayed 24hr Area Monitor Fire All inputs must be sealed with an EOL resistor even if unused For wiring details of Keypads Keyswitches Panic Buttons and Warning devices ZONE IS SEALED 4 0 4V see the wiring diagrams in the wiring section of this manual ZONE IS SHORT CIRCUIT OV TAMP Tamper Input ZONE IS OPEN CIRCUIT 8V 0 4V The TAMP input must also be sealed with a 2K2 end of line resistor This input is always a 24hr input KEY Keyswitch Input This a 24hr Panic input or an optional keyswitch input for Arming Disarming NOTE By default the KEY input is a Panic input To use the KEY input as a keyswitch input program P400E 1E this maps the input to Output Group zero which disables it as a zone 17 V AC TERMINALS These terminals are for the connection of the Ness plug pack The Ness D24 requires an AC transformer rating of 1 4 Amps 17V AC minimum Ness Part No POW215 EARTH For maximum protection against damage caused by lightning strikes connect a good earth to this terminal Alternatively use the Earth lead from the plug pack BATTERY These terminals are for the connection of a sealed lead acid rechargeable 12Volt battery Charge current is limited to 350mA The charge voltage is factory preset at 13 8V A 12 Volt sealed lead acid rechargeable battery must be
75. ones will be on P45E 2E AUTOMATIC ZONE TEST This test can identify potentially faulty detection devices by alerting the user to zones which have not unsealed during the past 20 Arm and Disarm cycles If selected the test runs during the normal operation of the panel If any non 24hr zone s does not unseal during 20 Arming cycles the D24 will alert the user by turning on the icon You can view the offending Zone s by pressing VIEW 7 The offending zone s icons will be ON To clear the Zone Test label unseal the offending zone s while still in the VIEW 7 mode This will result in the steady zone icon changing to a fast flash This will verify whether the zone is functioning correctly or not To cancel the display press the E button If the icon remains on press VIEW 7 then E 26 NESS 024 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT 0000 TO PROGRAM P 50E Client Code E RELATED OPTIONS P75xE Client Codes for Areas P51E P52E P53E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT none TO PROGRAM P 5xE Telephone number E NOTES The telephone numbers including special characters can be up to 18 digits long D PROG DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT Client Code Telephone Number 1 Primary Telephone Number 2 Secondary Telephone Number 3 Callback CLIENT CODE The clie
76. ovided 3 Bring the 4 connecting wires to the terminal block on the PCB on the rear of the keypad hous ing 4 Connect the wires to the screw terminals as per the wiring diagram shown in this manual 5 Clip the top half onto the base by first engaging the bottom clips and swinging the top closed Push hard to ensure the clips engage 6 Attach the Zone list label on the inside of the lid 91 KEYPAD D24 LCD KEYPAD The Ness D24 LCD keypad provides important visual and audible indication of the system status and is the main interface for controlling the many powerful features of the D24 system Information is displayed on a large LCD icon display which is backlit for easy night viewing NUMBER OF KEYPADS Up to 3 LCD keypads can be connected to the D24 BACKLIT LCD ICON DISPLAY VIEW BUTTON PANIC BUTTON ARM BUTTON MONITOR BUTTON AREA BUTTON EXCLUDE BUTTON PROGRAM BUTTON CABLE LENGTH The maximum allowable cable length is 100m total cable length to all keypads DISPLAY TEST To display all the keypad icons press and hold the E button for at least 2 seconds All the icons will be on whilst the E button is held down Display Test can be activated at any time either in operating mode or any program mode ENTER BUTTON 10 NESS D24 CONTROL PANEL INSTALLER MANUAL KEYPAD DISPLAY Table VIEW Menu Operation Flashing Flashing TAMPER ALARMS To view 1 E
77. r AREA2 60 Sec 7 8 Exit Delay Time for AREA 3 S isma THE PROGRAMMING OPTIONS SUMMARY 1 of 2 OPTION DESCRIPTION DEFAULT PAGE 261 268 Vibration sensitivity Wr rm shen octoutSysemlams al reese sien Looto over dams al Uu rss Boude Syt ams _ Powerd _ AREA 19 rome m none Two button keypad operation 20 Shortcut ARMING ON Shortcut EXCLUDE ON No Auto Exclude TT RN NN m 6E used AUX1 Armed E esci of MAPPING ZONES ALARMS TO OUTPUT GROUPS xx Output Group 0 31 Pin Map Zones when ARMED al Vap Zones when DISARMED al zones PDE rat me Mapoiows Map Tamper Alarms 28 PAO xxE Map System Alarms Pma vep CREATE INSTALLER DEFINED OUTPUT GROUPS METHOD 1 yyE Create installer defined Output Groups 1 15 Installation WALK TEST Select zones to test 26 Enable Auto Zone Test 54 NESS D24 CONTROL PANEL INSTALLER MANUAL INEZ D 4 PROGRAMMING OPTIONS SUMMARY Page 2 of 2 DESCRIPTION
78. roups Choose an Output Group 0 31 Turn ON the alarms required to be in the selected Output Group P39xxE P42xxE MAP ALARMS TO OUTPUT GROUPS These options set the output groups which various system alarms will trigger PROGRAM MODE LEVEL Installer Remote by PC when alarmed FACTORY DEFAULT P39xxE MAP TAMPER ALARMS see table P39 Output Group 0 31 E Tamper Alarm number E TO PROGRAM P Option No E Output Group E Alarm No E P40xxE MAP SYSTEM ALARMS Maps alarms to the selected output group P40 Output Group 0 31 E System Alarm number E NOTES Alarms can be disabled by mapping them to Output Group 0 P41xxE MAP POWER ALARMS P41 Output Group 0 31 E Power Alarm number E Alarms are removed from an output group by mapping them to a different output group To use the KEY input as a keyswitch input P42xxE MAP GENERAL PURPOSE TIMER program P400E 1E this maps the input to P42 Output Group 0 31 E 1E Output Group zero which disables it as a zone EXAMPLE To make zones 23 amp 24 into 24hr zones by mapping them to output group 17 P3817E 23E 24 Note xx refers to the Output Group number See the Output Groups table on page 24 NESS D24 CONTROL PANEL INSTALLER MANUAL 28 PROGRAMMING OUTPUT GROUPS Table Any combination of OUTPUTS can be GROUF to make an SIREN A SIREN B RESET STROBE AUX 1 AUX 2 Relay SONALERT FIRE SIREN A Burst 10 RESET Burst PRE
79. s are assigned to the Admin area When there are no zones assigned to areas a full Arm or Disarm turns the Admin area on and off COMMON AREA ZONES Zones assigned to more than one area are armed only when all the assigned areas are armed Common Area Zones will automatically Arm only when a the assigned areas are Armed Common Area Zones will automatically Disarm when any of the assigned areas Disarms OPERATION Operation depends on the type of user code being used Area operation only applies to zones when they are in the armed state This means that Day 24hr and Monitor zones are independent of the area operations Note Area partitioning is in addition and separate to Monitor Mode Zones 1 2 3 4 5 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 P311E Assign zones to AREA 1 P312E Assign zones to AREA 2 P313E Assign zones to AREA 3 P321E Assign zones to MONITOR 1 P322E Assign zones to MONITOR 2 6 7 10 PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT All zones assigned to Admin area TO PROGRAM P 31x E Zone No E Toggles the option ON and OFF NOTES e f no Area operation is required assign all zones to the Admin area P310E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT No monitor zones TO PROGRAM P 32x E Zone No E Toggles the option ON and OFF NOTES NESS D24 CONTROL PANEL INSTALLER MANUAL E
80. se to allow all perimeter zones doors and windows to be Monitored armed at night 24HR Zones Zones that have been setup to be active in any mode Usually used for Tamper switches and Panic buttons ARMING THE SYSTEM If the D24 has not been programmed for Area operation this method will Arm the entire system Press If Two Button Keypad Operation is disabled This is the factory default 0r E If Two Button Keypad Operation is enabled Or CODE E If Shortcut Arming is disabled Three beeps will sound 221 the ARM icon will turn ON Leave the premises within the Exit Delay Time At the end of Exit Delay Time 1 beep will sound J DISARMING THE SYSTEM If the D24 has not been programmed for Area operation this method will Disarm the entire system Press CODE E Three beeps will sound J J J and the ARM icon will turn OFF Disarm the panel during the Entry Delay Time to prevent unwanted Alarm entry 42 NESS D24 CONTROL PANEL INSTALLER MANUAL a OPERATION Most users of the panel should be assigned Area Codes An Area Code allows you to Arm and Disarm only the Area which has been assigned to that code This makes Area operation as simple as possible with the least number of keystrokes TO ARM YOUR AREA Press CODE E Three beeps will sound J J and your AREA icon will turn ON 1 om AREA 1 AREA 2 AREA 3 Leave the Area within the Exit Delay Time At the end
81. t option E DIALLER PROGRAMMING OPTION No DESCRIPTION DEFAULT REPORTING FORMAT 1E Audible PULSE format 2E Audible format Contact ID REPORTING FORMAT P54E 1E AUDIBLE PULSE FORMAT Audible Pulse format for reporting alarms to any telephone or mobile phone Reports the last digit of the client code and the zone number The call can be acknowledged the alarm by pressing the key on their telephone Press the key for at least 2 seconds during pauses in the audible message The basic audible message takes the form of N pause A pause B pause N The first digit of the Account Number P72E can be the digits 1 9 If P50E starts with 0 is not sent A First digit of the Alarm identifier B Second digit of the Alarm identifier P54E 2E AUDIBLE DTMF FORMAT The Audible DTMF message cannot be recognised unless decoded Audible Pulse format is the recommended audible reporting format P54E 3E CONTACT ID FORMAT Contact ID format is used for reporting alarms to the central station See page 58 for the full list of Contact ID reporting codes 28 NESS D24 CONTROL PANEL INSTALLER MANUAL PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Auto dialling TO PROGRAM P55E Select option E P57E PROGRAM MODE LEVEL Installer Remote by PC FACTORY DEFAULT Alternate dialling TO PROGRAM P57E Select option E NESS D24 CONTROL PANEL INSTALLER MANUAL
82. the premises Install the D24 panel as follows INSTALLATION 1 Insert the Rear Tamper Switch in the mounting hole in the base 2 Screw the base to the wall using at least 4 fasteners If mounting on an uneven surface make sure the rear tamper switch is correctly pushing in Insert the adjustable Board Clip Retainers in the positions as shown Insert the D24 Board Fit the Slots first followed by slots B The board should be mounted in the second highest position Attach the supplied Speed Nuts to both Bolt Posts Fit the removable terminal strips on the two rows of pins on the D24 Board Fit the Housing Lid Tamper Switch behind the right hand bolt post e i o p Connect both tamper switches using the tamper leads supplied and plug the tamper lead assembly into the J1 header on the D24 board 9 Fit the backup battery in the battery cradle The battery terminals should be at top 10 Complete the wiring of detection devices sirens telephone lead etc 11 Power up and program the control panel 13 Before exiting program mode fit the housing lid Clip the lid at the top first then swing it down Fasten the lid with the 2 bolts supplied The bolts can be made captive to the lid using the supplied circlips Top cable entry Square duct knockout Rear cable entry NESS SECURITY PRODUCTS 105 232 N m o uL 2 Sp CB S N a 2 e Cu N O N N O rN NON
83. trobes Ness Part No NOI300 can be connected to this output The output is protected by an Automatic Reset fuse SIREN A SRN A Siren driver output for connecting horn speakers Ness Part No NOI110 or 100 171 Internal Siren The output will reset at the end of siren time P28E or whenever the panel is reset whichever comes first This output has an internal Resettable fuse SIREN B SRN B Second siren driver output Same specifications as Siren A When by operating the D24 by optional Radio Key or optional Keyswitch Siren will chirp to provide Arming Disarming feedback if 34 2Eis enabled Siren Chirps ARMING 1 Chirp from Siren B DISARM 2 Chirps from Siren B MAXIMUM NUMBER OF HORN SPEAKERS The D24 supports a maximum of 3 x 8 Ohm horn speakers across SRN A and SRN B E g SRN A 2 horn speakers SRN B 1 horn speaker J6 LISTEN LINK Installer s diagnostic output Connect an 8 ohm horn speaker to listen in to dialler tones KEYPAD 12V OV CLK DATA for connecting up to 3 Ness D24 LCD keypads connected in parallel The maximum recommended cable run is 100m for 1 keypad using 14 0 20 cable Each additional keypad will reduce the maximum cable distance accordingly KEYPAD INSTALLATION 1 Unclip the top half of the keypad housing by pushing the top clips down with a small screw driver and pulling the housing forward 2 Screw the base of the keypad housing to the wall using the 4 mounting holes pr
84. umber of retries to enter a valid code may be set from 1 to 9 A value of 0 disables the alarm Factory default is 2 retries alarms on the second retry DURESS PREFIX To Disarm and simultaneously send a DURESS alarm prefix a user code with the Duress Digit when Disarming The Duress Digit can be any number from 0 9 Factory default is 9 Important if the Duress Prefix is to be changed be careful that you do not get an access code of Duress Prefix another access code This can only happen if access codes of mixed length are used and the Duress Prefix is changed after programming access codes OPTION No DESCRIPTION Default panel options Except Dialler User Codes Installer code and Entry Exit delays Default User Codes Installer code amp Entry Exit delays Default dialler options Clear Alarm Memory Clear dialler buffer FACTORY DEFAULTS Reset various programming options to factory default P981E DEFAULT PANEL OPTIONS Resets to factory default all options except Dialler options User and Installer Codes and Entry Exit delays P982bE DEFAULT USER CODES INSTALLER CODE amp ENTRY EXIT DELAYS Resets to factory default all User Codes Installer Code and Entry Exit delays P983E DEFAULT DIALLER OPTIONS Resets to factory default all Dialler options P984E CLEAR ALARM MEMORY Clears all events from the alarm memory P985E CLEAR DIALLER BUFFER Clears all outstanding alarm messages queue in the dial
85. xternal Tamper OFF ON FAST SLOW TAMPER 2 Control Panel Tamper Zone sealed Zone unsealed h eal present in Armed 5 Radio Interface Tamper or Monitor Mode Qe 2 Panel is Panel is Q _ To view 1 Keyswitch Panic Displaying SYSTEM 2 Dialler line fault ZONE Zone Status alarms 3 Keypad connection fault 4 Control Panel fault Displaying Tamper Alarms ow 3 E 9 Duress alarm TAMPER Normal individual present 6 Panic alarm Tamper Alarms 7 Medical alarm Displaying System Alarms 8 User Code alarm SYSTEM Normal individual present 9 Access to Installer Program mode System Alarms Displaying Power Alarms POWER ALARMS D POWER Normal individual present To view 1 Mains power failure Power Alarms POWER 2 Backup Battery low N Ei Fire al alarms 3 DC supply failed re monn e ean Ga 4 Zone reference supply failed mE a iie NEN eU 9 Radio Device battery low Normal Memory Mode New alarm in 0 Radio Key battery low pressed Panel is in Tii MEMORY DISPLAY MONITOR Monitor Mode MEMORY icon flashes to indicate MEMORY that Memory contains new events 1 AREA 1 MEN Area 1 Armed Wa Area 1 Monitor iew 2 Memory be viewed at any time 1 Press E 2 AREA 2 NEN Area 2 Armed 5 Area 2 Monitor 2 Memory icon f rs of Keypad icons will display the Area 3 Armed most recent event as per the Omens mmm _ eno Ona Zone or other 3 Step through the Memory N Cvew button At each step