TYC02017v2.1 Design Output---Hyrax PCP-100

image

Contents

1. pins Note that the earth connection is optional and may be left disconnected if the application doesn t require UNCONTROLLED IF PRINTED TEM0109 V1 12 07 05 USER MANUAL n te i design TITLE HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 4of8 electronic design and engineering 7 2 RS232 Serial ONOoORWDY z 2 Description Not connected Not connected Not connected Signal Ground Receive Transmit Clear To Send Request To Send COIN OD a AION gt 8 INSTALLATION 8 1 DIN rail mounting The Hyrax PCP 100 Field Processor includes a spring loaded DIN rail mounting bracket on the rear of the device Press the bottom edge of the bracket under the bottom edge of the rail push the device up and press the top edge back until it clicks into place 9 SERVICE HATCH The service hatch provides access to the micro USB console port the SIM card slot the micro SD card slot and the bootloader mode button Access is via a hatch on the top face A 2mm hex key can be used to remove the single screw after which the hatch can be lifted 9 1 USB console port A dedicated console port is available via the micro USB port See section 10 6 for details on connecting through this port UNCONTROLLED IF PRINTED TEMO109 V1 12 07 05 electronic design and engineering 9 2 9 3 USER MANUAL n te i design TITLE H
2. electronic design and engineering 5 INCLUDED EQUIPMENT The Hyrax PCP 100 development kit includes the following items e Hyrax PCP 100 DIN Field Processor e Terminal block power connector e EIA 561 RJ45 to DBO9 serial cable 6 PRODUCT OVERVIEW RA PCP 100 1E2S Option 1 Ethernet 2 Serial lO No Description 2G 3G antenna connection Bluetooth antenna connection GPS antenna connection WiFi antenna connection Power terminal block RS232 serial port 0 RS232 serial port 1 10 100bT Ethernet port 0 USB host port O dOINI DO a Cc n UNCONTROLLED IF PRINTED TEM0109 V1 12 07 05 USER MANUAL n te i design TITLE HYRAX PCP 100 electronic design and engineering QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 3of8 HYRAX w e Power Input 6 60VDC On intellidesign 2E1S Option 2 Ethernet 1 Serial IO No Description 2G 3G antenna connection Bluetooth antenna connection GPS antenna connection WiFi antenna connection Power terminal block RS232 serial port 0 10 100bT Ethernet port 1 10 100bT Ethernet port 0 USB host port O dOINI ODO a ico n 7 PINOUTS AND WIRING 7 1 Power Power connections should be made as per the front panel markings 6 to 60 VDC should be provided between the and
3. YRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 5of8 SIM card and micro SD card slots The SIM card slot sits underneath the micro SD card slot To insert the SIM simply push the card into the slot To eject the SIM again push on the card and release To insert the micro SD card simply push the card into the slot To eject the micro SD card again push on the card and release Figure 1 Hyrax PCP 100 service hatch Bootloader button A recessed button is accessible under the service hatch for putting the unit into bootload mode Power off the unit and then using an appropriate tool hold the button in as the unit is switch on Once the unit is in bootload mode the NAND flash can be written using a tool such as SAM BA When writing images to the NAND memory the following locations should be observed Address File 0x000000 nf boot bin 0x040000 u boot bin 0x180000 dtb 0x200000 ulmage 0x800000 rootfs UNCONTROLLED IF PRINTED TEM0109 V1 12 07 05 electronic design and engineering 10 10 1 10 2 10 3 10 4 10 5 USER MANUAL n te l design TITLE HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 6of8 SETUP AND CONFIGURATION Applying power The Hyrax PCP 100 Field Processor accepts a wide DC input voltage range Wire the terminal block power plug to a DC power supply rated to at le
4. ary 2014 Removed irrelevant unimplemented sections LEF 15 October 2014 Updated sections to document OpenWRT build UNCONTROLLED IF PRINTED TEMO109 V1 12 07 05
5. ast 3W and outputting between 6V and 60V When power is applied the green power LED should illuminate and the unit will begin to boot Accessing the Hyrax PCP 100 via the Ethernet interface Connect one end of an Ethernet cable into the ETH O0 port on the Hyrax PCP 100 Field Processor Connect the other end into a network switch or hub By default the unit is assigned a static LAN IP address of 192 168 1 1 The unit must be connected to a test 192 168 1 0 network and the IP address 192 168 1 1 must be available for use Accessing the Hyrax PCP 100 via the WiFi interface The Hyrax PCP 100 Field Processor is configured as a WiFi access point by default The access point details are as follows SSID Intellidesign FP2 Password MyPASSWORD The default IP address of the WiFi interface is set to 192 168 2 1 OpenWRT web configuration Ul pages can be accessed using any web browser Use the following login details Username root Password openwrt OpenWRT web configuration UI Web configuration Ul pages are accessed over the WiFi access point network Using any web browser goto the 192 168 2 1 address and login using the details shown in section 10 3 LAN WLAN and WAN settings and connections can be managed from these pages along with a range of other features Remote console via SSH By default you will have access via remote console on the wired and wireless network interfaces Connecting via remote console requires a
6. detect this device as a USB gadget serial port and a COM port number will be assigned The COM port number can be found by looking in Windows device manager Expand COM ports from the device tree and look for the serial gadget device The COM number should be shown in brackets beside the device In Linux the device will appear as a CDC ACM device and a Linux kernel with CDC ACM support will create a net serial device dev ttyACMx where x is the next unassigned port number Using a terminal program such as PuTTY connect to the serial COM port using 115200bps baud 8 bit data 1 bit stop no parity and no flow control ES C R PuTTY Reconfiguration i Category Session Options controlling local serial lines Logging Configure the serial line J Terminal Keyboard Speed baud 115200 E Data bits 8 Features Window Stop bits 1 Appearance Parity eos xi Behaviour L Translation Flow control None Selection Colours Connection Apy e Cancel A The terminal window will appear blank Press the enter key to see the prompt No login details are required when connecting via the USB console port TEM0109 V1 12 07 05 USER MANUAL n te l design TITLE HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 8of8 electronic design and engineering 11 REVISION RECORD VERSION INITIALS DATE CHANGES 18 November 2013 19 Febru
7. electronic design and engineering USER MANUAL n te j design TITLE HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 1of8 CONTENTS PURPOSE rninn nV e YN NENE r r N E N EET E EiS 1 PM ized M 1 3 REFERENCED DOCUMENTS trottoir tkt oup o eoa Ca el e coa oe ELE UR b Yea y eo ced Co E RR YR e pa eia dag eund 1 45 ABEFINITIONS mro ERRORI EURO 1 5 INCLUDED EQUIPMENT EE 2 6 PROBUGT OVERVIEW enin ettet eoe eti tete te E HEC E LH ie eie de itid tete een tee eee ees 2 f PINOUTS AND WIRING iit irri cu eer pi tuor to cei to Ea eue eoe eave eben Feed oven E RU V ER sure ua e eR PL eben i taa 3 3 sA POWER Ges sr SINN Ntc 3 2 RS292 SERIAL os cie inan tn rr re m TRE c re d ti cedat ar eai a aeiaai 4 8 INSTALLATION seek ierit eee lee eee ee ie e Se ei de ire v IH NE 4 X DIN RAIL MOUNTING iz secs c cee 4 9 SSERVIGE FA GEL s Eie a gue ed aS GI IOI EB EU CRUCE CH RII 4 9 1 USB CONSOLE POR iae te tee eter ree e rt a RE T ted E e dE ou cbe eA E e a EFE vedi Y Pret ena a 4 9 2 SIM CARD AND MICRO SD CARD SLOTS s ee eee ete ee tease tenes cane seaeeseaeeseaeeseeeseaeeseaeeseaeesueseseeseeeseneenaes 5 9 3 BOOTLOADER BUT TON 4 rre ii eoi ca sca ru snes to od o nca e e E SEE DR os REL ER oda eo Led a ER o ve e ka e
8. n SSH enabled terminal program such as PuTTY To connect through PuTTY select SSH as the connection type and enter in appropriate IP address as the Host Name Click Open to begin the session eth 192 168 1 1 wlan0 192 168 2 1 UNCONTROLLED IF PRINTED TEMO109 V1 12 07 05 electronic design and engineering 10 6 UNCONTROLLED IF PRINTED USER MANUAL intellidesign m HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 70f8 You will be prompted to accept an authentication key from the remote address Answer yes to continue In the terminal window a login prompt should appear Enter the following credentials to log in Username root Password openwrt Note Any subsequent changes to the network settings may result in a loss of connection and a loss of console access Please keep this in mind when updating wired network settings via command line or the web configuration UI Connecting via the console A dedicated console connection is available through the micro USB console port Insert the type A end of the USB cable into a USB port on your PC Plug the micro USB end into the console port connector on the Hyrax PCP 100 Field Processor As the unit boots the PC will detect a new USB device In Windows you will be asked to provide a valid driver The Windows driver file inux cdc acm inf is included with the development software pack in the folder drivers Windows Windows will
9. od eoe RR Eua 5 10 SETUPZAND GONEIGUEGATIGN 2 ree tere mee e e ER OR RR 6 10 1 APPLYING POWER itte e tee tbe Ru sie Ite eta Li E SEE doen E EEUU ERREUR ERE a cove Ue Ee EHE vu rb eei vee 6 10 2 ACCESSING THE HYRAX PCP 100 VIA THE ETHERNET INTERFACE sscssssssssssessessessessesessecseeseassascseeseeseeneaes 6 10 3 ACCESSING THE HYRAX PCP 100 VIA THE WIFI INTERFACE c scsscsssssesssssescesesseeseessssesesecsecsecseareseseeseeseeseans 6 10 4 OPENWRT CONFIGURATION 1 ier ees eee ere er ter e RE EHE EE EE REO HR DUE EIS 6 10 5 REMOTE CONSOLE VIA SSH rettet e etta tee t teet nde eU E LL a eb RE Y UL dE eee ees 6 10 6 CONNECTING VIA THE GONGSQOLE 5 2 otro tritt eet tede oleo oleae II eripe t Le e e Ede de idek 7 11 REVISION RECORD bis sce 1 8 1 PURPOSE 4 1 The purpose of this document is to provide a basic guide to setting up the Hyrax PCP 100 Field Processor RESPONSIBILITY The Hyrax PCP 100 Field Processor project design engineer shall be responsible for the generation and maintenance of this document REFERENCED DOCUMENTS None DEFINITIONS FP Field processor SIO Serial input output Ul User Interface USB Universal Serial Bus UNCONTROLLED IF PRINTED TEM0109 V1 12 07 05 USER MANUAL n te i design TITLE HYRAX PCP 100 QUICK START GUIDE DOC TYC02017 VERSION 2 1 DATE 15 October 2014 PAGE 2of8