Master Channel Generator Type G 3890 0014 Modbus RTU Version

image

Contents

1. current lt 100 pA Short circuit protection None Built in protective diodes None Dielectric voltage Output Dupline Output Input Inductive loads gt 4 kVAC rms gt 4 KVAC rms External noise suppression required G 3890 0014 Input Output Specifications cont Back up supply Real time clock Input Function Dupline General Specifications Real time clock Accuracy Better than 1 minute month Isolated in groups of 1x1 Internal back up time Typ 120 hours Input voltage range 45to9V Unit parameter back up time gt 1 year Reverse polarity protection Yes Power ON delay lt 258 Rated operational current 10 to 100 pA indication f Input resistance gt 47 KQ nee noe Supply ON LED green Cable length lt 0 5m ON Line IED yelow Dielectric voltage Busy LED eee Input Dupline 230 V Version gt 4 kVAC rms Fault LED red Input Dupline 800 V Version 500 V Adjustment 4 tactile pushbuttons Time Date Year Day Time date etc 4 digit LCD display red background light Environment Mode Up Down Enter P i Degree of protection IP 20 Pollution degree 3 IEC 60664 Operating temperature 0 to 50 C 32 to 122 F Storage temperature 20 to 85 C 4 to 185 F Humidity non condensing 20 to 80 RH Mechanical resistance Shock 15 G 11 ms Vibration 2 G 6
2. Master Channel Generator Type G 3890 0014 Product Description Programmable channel gen erator with built in intelligent functions for light control alarm monitoring AnaLink set point control rollerblind control etc Programming is easily performed through Type Selection Supply 115 230 VAC 10 to 30 VDC windows based configuration software A specific function with associated parameters can be assigned to each address and logic operations can be used to link the func tions together Ordering no G 3890 0014 230 G 3890 0014 800 Supply Specifications Power supply AC Types Rated operational voltage through term 21 amp 24 jumper term 22 amp 23 jumper term 21 amp 23 and term 24 amp 22 Frequency Rated operational power Rated impulse withstand voltage 115 230 V Dielectric voltage Supply Dupline Supply Output Supply Input Supply Com ports Overvoltage cat Ill IEC 60664 230 VAC 15 IEC 60038 115 VAC 15 IEC 60038 45 to 65 Hz Typ 7 VA 3 W 4kV gt 4 kVAC rms gt 4 kVAC rms gt 4 kVAC rms gt 4 KVAC rms Power supply DC Types Rated operational voltage through term 21 amp 22 Reverse polarity protection Rated operational power Inrush current Rated impulse withstand volt Dielectric voltage Supply Dupline Supply Output Overvoltage cat Ill IEC 60664 10 30 VDC Yes Specifications are subject to change without noti
3. based configuration software the unit can be con figured to perform real time control logic and timer func tions ISA water smoke and Intruder alarm monitoring and Code Door lock armouring Print outs of time tagged user defined text in case of channel output changes Keys In the display mode the four front keys are used to change the display showing time date day of the week year or soft ware revision of the master generator Press lt enter gt The keys are also used to set the time date day of the Pin Assignment week year and definition of operation and parameters of the parallel ports Display The back lighted 4 digit LCD display is used to show all the relevant information that can be changed by using the keys If no key is pressed for 2 min utes the display automatically shows the actual time In case of an Error the display shows an Error code Back up Terminals In case of missing power the internal calendar and clock are supported by a super capaci tor Under normal ambient temperature this back up will maintain the correct date and time for typically 5 days If longer power shutdowns can happen an external battery of 4 5 to 9 VDC may be connect ed between terminal 35 and terminal 36 Alarm Output Terminals An open collector NPN transis tor output with NC function signals alarms and faults in the system Attention by the local personnel is requested when ever this
4. ce 18 09 00 Dupline is a registered trademark A product of the CARLO GAVAZZI Group Dupline e Programmable channel generator e Configuration based on Windows 95 98 NT software e Light control functions e Alarm monitoring e AnaLink set point control e Rollerblind control e Real time timer and logic functions e Print out of events with date and time tags e H8 housing e For DIN rail mounting EN 50022 e AC or DC power supply e Modbus RTU interface RS 232 only version gt 2 02 e Option for connecting two Dupline Master Channel Generator Networks only version gt 2 02 e Multiplex or normal mode Ordering Key G 3890 0014 230 Type Dupline H8 housing Master channel generator Supply Input Output Specifications Serial Port RS 232 9 pole female SUB D Pin assignment T D Pin2 R D Pin3 GND Pin5 Dielectric voltage Com port Dupline gt 2 kVAC rms Parallel Port Centronic 25 pole female SUB D Pin assigment Strobe Pin 1 Data D0 D7 Pins 2 9 Busy Pin 11 Paper out Pin 12 GND Pins 18 25 Dielectric voltage Com port Dupline gt 2 kVAC rms Dupline Output Dupline carrier Output voltage 8 2 V Current lt 100 mA Short circuit protection Yes Sequence time 32 channels 38 6 ms 128 channels 132 3 ms Watchdog Output 1 NPN transistor Function Watchdog Output voltage Vov lt 35 VDC Output current lt 100 mA Output voltage drop lt 2V Off state leakage
5. ntroller 1 to Controller 2 20 O2 5 OQ 05 70O O7 80 O8 W Dupline Networks Cable 9 pin male 9 pin female to controller to PC 2O O2 30 O3 70O O5 80 O7 50 C 8 Configuration Cable Specifications are subject to change without notice 18 09 00 Dupline is a registered trademark A product of the CARLO GAVAZZI Group Modbus RTU Memory Mapping Dupline Function Code 03 Data Word Function Code Dupline Read Register 01 02 05 Channel Word address MSB HB LB LSB Address 0000 B8 B1 A8 A1 0000 A1 0001 D8 D1 C8 C1 0001 A2 0007 P8 P1 08 01 007F P8 100 AnaLink A1 101 AnaLink A2 17F AnaLink A8 Function Code 06 16 Write Register Word Address MSB HB LB LSB 0000 B8 B1 A8 A1 0001 D8 D1 C8 C1 0007 P8 P1 08 01 Scope of Supply Accessories 1 x Master Channel Generator G 3890 0014 User manual MAN G3890 0014 ENG 1 x User manual MAN G 3890 0014 ENG RS 232 9 M 9 F 1 x RS 232 cable 1 x Configuration software RS 232 9 M 9 F SW G 389XX14 version 2 00 For further information refer to Accessories Specifications are subject to change without notice 18 09 00 Dupline is a registered trademark A product of the CARLO GAVAZZI Group
6. output switches off The display and or the LED s gives an indication of the cause of problem Master Generator Configura tion The master generator is as factory default configured to operate as a standard chan nel generator without intelli gent functions To obtain full utilisation of the advanced fea tures the generator has to be configured For configuration the delivered software SW G 3890 0014 has to be installed on a Win 95 98 NT based PC This software handles all con figuration of the G 3890 0014 master generator Configuration is done entirely RS 232 Cables on the PC and when complet ed the set up is downloaded into the generator via the serial port COM1 or COM2 Two Dupline networks Two channel generators can be connected via communica tion cable Thereby addresses i e master commands can be transferred from one network to the other Modbus RTU Modbus RTU is implemented as a function of a slave The following Modbus function is supported 01 02 03 05 06 and 16 All 128 Dupline Digital channels are placed from Word no O to 7 All 128 Dupline AnaLink signals are placed in Word 100 to 17F Rev 2 02 or higher required Gea 6 9 Pin Signal 2 TxD 3 RxD 5 Signal Ground 7 RTS 8 CTS GRRE 25 14 Pin Signal 1 Strobe 2 9 Do D7 11 Busy 12 Paper out 18 25 GND 9 pin male 9 pin male to co
7. to 55 Hz Dimensions Material see Technical Information H8 housing Weight 540 g Wiring Diagrams G 3890 0014 230 G 3890 0014 800 Dupline 0 1A Dupline O1A a rS 35v pS 35 V f oa tte st4 ste 7 a 9 ro m 12 13 14 15 16 i 27 sf 47 5 6 7 8 97 10 11 12 13 14 15 16 We Centronic If f EJ Centronic J Noise red Watchdog NPN Noise red Watchdog NPN Rs 232 I ra RS 232 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Backup Backup 4 5 9 V 7 45 9V Supply 10 30 VDC 7W Supply Power supply 230 VAC Power supply 115 VAC Key Operation Diagram Display Show Show day Show Time of day date p gt pi gt yea Main Setting Mode Set U Set Time Set Date Set Set SEH Time Format Date gt Format p gt Day p Year HrS FOr dAtE FOr dAY YEAr 2 Specifications are subject to change without notice 18 09 00 Dupline is a registered trademark A product of the CARLO GAVAZZI Group G 3890 0014 Mode of Operation Dupline The G 3890 0014 master gen erator is a programmable channel generator which is particularly well suited for building automation applica tions like light control roller blind control temperature con trol and alarm monitoring Through an easy to use win dows

Download Pdf Manuals

image

Related Search

Related Contents

Prima Games Haze, EN  SINGER is sewing made easy.™  Balança Pesadora Manual do Usuário - w w w . u p x s o l u t i o n  Duplex Pressure Powered Pump Packaged Unit  Instruction Manual  VRF DX Interfaz Manual de Instalación  sicherheitshinweise bitte bewahren sie diese auf  Maxell UR-90 5pk  Philips DTM3155/12 docking speaker  USER`S MANUAL - Mitsubishi Heavy Industries  