Home
porta-rapida-beloxi_..
Contents
1. Wiring diagram of limit switches J3 If the aceleration or desaceleration wasn t correct please change the motor connections 9 Common breakdown phenomenon and solution Breakdown phenomenon Electrical machinery two directions cannot rotate The electrical machinery opens the door normally closes cannot move The electrical machinery changes opposite Reason Frequency changer or control panel radio Electrical machinery hot protection swith movement Problem in the infrared According to the scene request Electrical machinery revolution direction needs adjustment Solution The replacement insurance inspects the power source Connect the line After waiting the temperature reduces the electrical machinery to move again According to above explanation correct connection Electrical machinery output terminal the U V W random two lines exchange and pays attention decelerates limits the position switch s direction is whether normal The electrical machinery revolves stops the frequency changer display monitor demonstrates wrong harms code OC OU OH OL Olt OCR The load is overweight surpasses the frequency changer peak power output Brakes the resistance not to connect Choice power big frequency changer Brakes the resistance connection to be correct The electrical machinery
2. Fast Door BELOXI English Fast Door BELOXI Installation Manual WLLL Please read carefully before any assembly or installation VER 1 02 REV 12 2011 Fast Door BELOXI English A Warning to installer and user 1 WARNING It s very important to your safety that this instructions are followed The bad installation or wrong appliance can damage people or materials 2 Keep these instructions in a safe place for future reference 3 This product was designed and produced strictly for the use indicated in this manual Any other use then expressly mentioned may damage the product and or be a hazard to people and void the warranty 4 ELECTROCELOS S A is not responsible for the incorrect use of the product or by using other than that for which it was designed 5 Do not install the product in an area where there is danger of explosion gases or flammable fumes are a serious security threat 6 ELECTROCELOS S A is not responsible if the safety standards weren t taken into account in the manufacture of the element to be automated or any deformation that may occur at the same 7 Before the installation turn off the power 8 The devices ex photocells should be used for prevent injury in people or materials 9 ELECTROCELOS S A is not responsible for safety and proper operation of the product when isn t used components sold by itself 10 Do not make any changes to the components of the engine and their ac
3. Page 17
4. will lock in this is unable to open 8 3 Wiring for external control Bele pelelele AC1 AC2 COM PHOTO OPEN STOP CLOSE GND DTOP LOCK PUSH NC CO NO Push switch Open Stop Close Wall switch 8 4 Wiring for external receiver Dele E E E N E AC1 AC2 COM PHOTO OPEN STOP CLOSE GND DTOP LOCK PUSH NC CO NO RECEPTOR CH Page 08 Fast Door BELOXI English C Central Schematic 8 5 Wiring diagram of limit switches Meets to the door opener interior micro active switch micromove switch sensitive switch cae I L 1 l l 1 1 1 I F 1 1 l I 1 1 1 1 I I 1 1 I I 1 l 1 I 1 1 1 l I I 1 1 1 l l L 1 l uol 99 010 uol 99 010 uone1aj299p uole19 29aP AU SASO D e lt y JOOP ay su do y JOOP ay su do Aisulyoeuw jeo ea Aisulyoeuw jeong
5. has not decelerated the stop On electrical machinery s deceleration switch is away from improper with the limit switch According to requests to readjust deceleration limit switch Page 9 Fast Door BELOXI English 10 Inverter parameter setting CAOS OY vor Press the button MODE and the display shows P 000 Next press button SET and then with the help of buttons A e Y choose the parameters to modify Whenever you want to save the chosen value press button SET for more than 0 5 seconds See page 5 Setting inverter parameters won D A RUNO l a ss ExT The first bit flashs The second bit flashs The third bit flashs Lo u D WA pu e E Pru at ae ae HZ pu o HZ o UE 3718 o P00 joc pers PISO eo a Lr a g we Z l2 Z lO mel z222 z O ve zaz O nz e FU EDU A e E ie ru T D ru 10 a ru Ow MONO H O v monO l O v e mono l Ory RUNO EXT RUNO le O ext v RUNO O ExT Enter the next Read iat a setting mode ead previous setting value Setting value write n and flashes Read new se
6. is 7 except white sheet following the BS 3424 norm The form to achive the termic isolantion is K A L 67 Wm2 K Page 03 Fast Door BELOXI English C Central Schematic 4 Central Schematic Ae Z 1 Air switch 5 Display 9 Close button 2 Brake Resistance 6 Central switch 10 Pause button 3 Frequency changers 7 Emergency stop switch 11 Opne button 4 Control circuit 8 Control box lock Figure 1 Control box scheme Alernating current supply input O O Air Switch Frequency changer Control Panel Figure 2 Control box wiring diagram Page 04 Matkavline Fast Door BELOXI viy S English C Central Schematic pg AC220V N MAGNET cs os pT cL oL com STF STR M2 M1 MO SD SO SE 7 r lele T lel YW WBQHKH DIII Q 3 S F1 LED2 LED3 LED4 LED5 LED6 LED11LED10 LED9 LED8 LED7 a S O e OO Wel m g S SI Mi MCU Q z Ti 6 LED2 LED q a
7. ase of abrupt acceleration deceleration 2 Avoid abrupt load increasing 3 Check wether there is short circuit among U v and W 1 Check the capacity of the external thermal relay and the motor for matching 2 Reduce the load ory Peripheral devides are abnormal 1 Abnormal communication The maximum communication retry number is violated 2 Interrupted communication The maximum communication check time is violated Correctly set the communication parameters EEP Memory is abnormal CPU CPU error The memory ROM fails External electromagnetic disturbance is too strong Send it back to the factory Improve external disturbance OLS Stall prevention protection The load of the motor is too heavy 1 Reduce the load of the motor 2 Increase the value of Pr22 weer tok IGBT module is too hot The temperature of IGBT module is too high 1 Reduce the environment temperature and improve air condition 2 Check wether the fan of the inverter is damaged Page 12 Fast Door BELOXI English 1 Drum 11 Scooter slider 2 Electronic table 12 Photocell with support 3 Nylon 13 NOT applied 4 Ear muff Support 14 Axis covers 5 Axle bushing 15 Reducer 6 Separator medium reducer 16 Motor 7 Aluminum Guide 17 Limit switch box 8 PVC tarpaulin 18 Axle short 9 Photocell mirror with stand 19 Photocell support 10 Counterweight with security sy
8. cessories 11 The installer should inform the customer of how to operate the product in an emergency case and provide the manual of it 12 Do not let the children closer to the door of the moving parts automatically when they are in motion 13 Keep controls out of reach of children to prevent any accident 14 You shouldn t in any circumstances attempt to repair or tune the automatic and must call an end to this Technical qualified 15 The automation should be installed to be protected from elements Exposure to water rain humidity or excessive dust may void the warranty of the product 16 Connect the automatic taking of a protected 230 V with ground wire 17 Automation for use inside Page 02 Fast Door BELOXI English B Thechnical Specifications 1 Motor Specifications Model Supply Voltage Electrical power Insulation grade Hot protection Operation temperature Rotational speed Outup torque Frequency power Diameter Biggest height of lift 2 Central Specifications Work power source Relative humidity 3 Sheet Specifications 230V 220V 50Hz 750W 130 C 20 C a 40 C 1440RPM 15Nm 750W 25mm 7m AC 230V 50Hz 1500W 20Hz 120Hz 10 C a 55 C The fabric weight is 5000 x 5000 mm with a thickness of 0 8 mm The resistence is 3500 N 5cm following the BS 3424 norm The tear resistence is 600 N The working temperature is 30 C 70 C The light resistence
9. inverter long timely perating under overload condition THA Motor overheating The electronic thermal relay operates 1 Check wether the setting value of the Pr9 is correct or not the setting should comply the actual motor 2 Reduce the load bE The brake transistor is abnormal The brake transistor is abnormal Please send it back to the factory Page 11 Fast Door BELOXI English DD AE lat ivelamiazrelec varenmuir lalerel mu LIL I OLI Current stall When the output current is larger than the set value it will display ZL to indicate that the inverter is in current stall mode In this case the motor may not run smoothly Solution 1 Check if the values of Pr22 Pr23 Pr66 are proper 2 Check if the values of Pr7 and Pr8 are too small ry LILLI OLV Voltage stall When the voltage between P and N is too high the inverter will display Ulu The motor may not run smoothly 1 Add a brake resistor between P and Pr 2 Check with the specified voltage Lu LV Low voltage Input voltage is low 1 Supply with the specified voltage i Litt OLT LT motion mL LTI The external thermal relay operates When the output current is more than twice the rated current but ir doen s reach the stall level the inverter will display ULI The motor may not run smoothly The external thermal relay operates 1 Please increase the acceleration deceleration time in c
10. ion Infrared connected in a contact NO normally open Fig 7 PHOTO OFF infrared protection Infrared connected in a contact NC normally closed Fig 8 ON ON 1 2 1 2 Figure 7 Figure 8 Note Must use always infrared protection 8 Connections 8 1 Infrared protector COM PHOTO OPEN STOP CLOSE GND DTOP LOCK PUSH RECEPTOR TRANSMISSOR 12VAC Note If in the gate body downward movement process this signal is effective time the gate body stops and returns to the upward movement immediately Page 07 e Fast Door BELOXI sre English C Central Schematic 8 2 Interlocking system S a AD He AC1 AC2 COM PHOTO OPEN STOP CLOSE GND DTOP LOCK PUSH NC CO NO Interlocking system between two doors Will need chain like another hanger on spacing condition switch turning on may realize the double gate chain like Function when another gate body is at opens the door the condition
11. llelele elelelelielele o AC1 AC2 COM PHOTO OPEN STOP CLOSE GND DTOP LOCK PUSH G co 0 O J1 AC 220V Input J6 Open Close Stop Buttons J2 Electromagnetic brake output socket S1 DIP switch selector J3 Spacing input post F1 2A fuse box J4 Frequency changer output terminal T1 Transformer J5 External connection control signal Vri Automatic closing time adjustment potentiometer Figure 3 Control circuit schematic drawing 5 Setting inverter parameters Base frequency Opening speed Closing speed Page 05 Fast Door BELOXI English C Central Schematic 6 LED indicating lamp function explanation LED 7 Opening door LED 8 Closing door LED 9 Electrical machinery protection LED 10 Opening door with deceleration LED 11 Closing door with deceleration 7 Control panel establishment 1 DIP switch establishment Figure 4 DIP 1 ON Closes automatically when we adjust the pause time in Vri Causes the delay time to meet the requirement the time regulation band is 1 30 seconds Fig 5 OFF Closes automatically invalid closes not automatically the function Fig 6 ON ON 1 2 1 2 Figure 5 Figure 6 Page 06 Fast Door BELOXI English C Central Schematic DIP 2 PHOTO ON infrared protect
12. stem Page 13 Mataviine Fast Door BELOXI SR EUVCUE FELIS English F Montagem da Porta Rapida 2 After setting the medium it can be level the sheet through the screw that 1 The door is placed vertically you see in the image 3 Place fixing screws to the floor in the support 4 Use the handle to unlock the door Page 14 Fast Door BELOXI English You should be careful to place 1 cm off the bottom of the door as a safety measure Must be sure that the sheet enter 5 cm in each side the tab Don t forget to link the earth wire to the screw Page 15 Fast Door BELOXI English Don t forget to set the end stop when you finish the assembly Before put the door working please put the sheet in the mid term To don t force too much the sheet in the first use Put the function selector in JOG position and start to rise the door and fall the same until you reack the limit When you achive that point please screw the selector Page 16 Fast Door BELOXI English G Sistema Anti Choque Warning anti shock system System created to save people from the collision between them and the door when the door is on motion 1 After the assembly please note if the safety system is like in the foto 2 After the assembly put the screw in the linker and tighten him 3 After assembly the safety system must be as in Figure NOTE The user must verify the battery at least one time a year
13. tting value pu T Hz Mon pa l O x RUN f l im O ExT Page 10 Fast Door BELOXI English DACE EA AE ULE U 11 Errors Inverter 1 Under voltage for power supply 2 RES terminal is connecter 3 Bad connection between the manipulator and the main machine 4 Internal circuit malfunction 5 Wrong operation of CPU Solution 1 Provide a normal power supply 2 Shut off RES 3 Ensure firm connection between the manipulator and the main machine 4 Replace the inverter 5 Restart the inverter ac Over current during acceleration ole Over current at constant Speed HIE Over current during deceleration The output current is two times larger than the rated current of the inverter 1 In case the time for acceleration or deceleration is too short prolong it 2 Avoid abrupt increase of load 3 Check terminals U V and W for short circuit Gul Over voltage during acceleration lug Over voltage at constant speed Gud Over voltage during deceleration Over voltage between Terminal P and Terminal N 1 In case the time for acceleration or deceleration is too short prolong it 2 Check the brake resistor between terminal and PR for loose connection 3 Check wether the values of Pr30 and Pr70 are right or not THF The IGBT moule is overheating The IGBT module thermal accumulating relay acts Avoid the
Download Pdf Manuals
Related Search
porta rapida beloxi_..
Related Contents
ペツル 取扱説明書 ナバホコンプレ Tube Expansion Torque Control Guía de instalación del soporte de lectura para la fiche de vente fond plat PDF-Beschreibung EuroLink Pro (Plus) - KOMETEC, Online Reflex Instruction card Prism Mini Centrifuge - Labnet International LG MF-PD330 User's Manual PASCO Specialty & Mfg. ME-8987 User's Manual Copyright © All rights reserved.