1. Data sheet Software product Server Management PRIMERGY RemoteView V3 0 www fujitsu siemens com Remote maintenance and diagnosis for PRIMERGY Servers Reliable efficient server management re quires components both for normal operation and for the eventuality of disruptions The integrated server management solutions of Fujitsu Siemens support smooth local and re mote operation of the IT infrastructure They help to increase availability and to cut ad ministrative costs considerably RemoteView supplements the server man agement for PRIMERGY servers and storage extensions with a solution for efficient reliable and low cost remote control diagnostics and maintenance Remote management is possi ble in all system states and at any time via LAN or modem with central Windows or Web based management stations In conjunction with the RemoteView Service Board RSB RemoteView 3 0 is an autonomous system within a system The RemoteView Service Board has its own operating system SNMP agents user and alarm management Web server and optionally an independent power supply Remote error diagnosis and error correction reduces time consuming and costly on site assignments to a minimum and helps select the spare parts specifically needed Highlights RemoteView supports the high availabil ity and security functions of the PRIMERGY servers Windows or web based user interface as a stand alone version or integrated into
2. Further Features and Technical Data Functions with RSB LAN or WAN access Web access to management information in all system states SNMP access in all system states Integration in ServerView Front end Console redirection text mode amp recording not available for PRIMERGY B120 Console redirection N200 C150 and L100 witha COM connection between system and RSB only BIOS set up NOS boot control Screen capturing of last two screens e g NT blue screens Remote power on off and reset capabilities Error and event log Own alarm management Notification via SMS mail or pager Optional external power support or battery board RSB in a PRIMERGY S60 Remote access for configuring the S60 RAID controller Power management remote power on off Access to sensor status information about Hard disks O modules FC PBC Hub loop node DAC Error and event log Configuration via HTTP user interface Security SSL MD5 RC4 Firmware update via LAN TFTP Direct alarm forwarding RTDS Remote Test and Diagnosis System Readout error and event log of the server Readout of system information identification number system board incl memory HW configuration operating times non volatile error memory temperatures fan speed Generating and displaying of the hardware inven tory list List of all PCI devices Configuration of hard disks and RAID systems Administering storage subsystems
3. ServerView Automatic Server Reconfiguration amp Restart function ASR amp R restarts auto matically when detecting certain errors with the operating system or the hard ware Configurable automatically start of RemoteView Efficient alarm management for quick and reliable information of administrators or service providers FU ITSU COMPUTERS SIEMENS Can be controlled locally at the server or remote administration via Modem or LAN via SNMP or HTTP protocol Remote restart of the system reset power on off Console redirection text with Telnet Security functions such as password protection and logging of remote activities are integrated Callback can be used during modem operation In LAN opera tion automatic encryption of the data transmission and the authentication takes place Product structure of RemoteView 3 0 RemoteView 3 0 software is the soft ware part including license on CD for administration setting up of a remote connection remote test and diagnostics RTDS and a BIOS update Supplements are DOS RomPilot the RemoteView online user manual and an online help system RemoteView Service Board see separate data sheet is a PCI board which can optionally be preinstalled at factory or can be ordered separately to gether with connection cables RSB to system board RemoteView Diagnostics comes with chipDISK an internal storage medium IDE flash disk with preinstalled DOS and the Remote
4. Test and Diagnosis Software in English installation material and a online manual RemoteView external power supply External power supply unit for the RSB RemoteView battery board autonomous power supply unit provides the RSB with power for several hours Functions without RSB Via LAN Connection between server and management station Will be established during power on self test POST Decision at the management console to Boot the normal operating system Start DOS with Remote Test and Diagnosis System RTDS Stop the boot process s available for PRIMERGY H N K400 H200 470 670 20 and 670 40 F L P200 C200 C150 L100 with remote console manager RCM and H250 Monitoring diagnosis of POST power on self test Remote operating of the BIOS set up Authentication and data encryption Remote connection of a floppy disk image Via modem Automatic start of DOS and RTDS via Automatic Server Reconfiguration and Restart ASR amp R The server can be dialled from the management console Only for PRIMERGY N800 Switchover of BIOS and console via Emergency Management Port EMP Automatic call back by the server not N800 Null modem support for on side test and demon stration Data transfer between server and remote adminis trator Via LAN or modem Automatic restart in case of a mal function Logging remote administrator activities Password protection Operating of RTDS Page 2 of 3
5. ictions The adminis trator software works under Windows NT and Windows 2000 respectively with standard Web browsers Approvals There is general compliance with the safety require ments of all European countries and North America National approvals required in order to satisfy statutory regulations or for other reasons e g for Canada and USA eastern European countries Norway on request Compliance with standards for IDE storage medium Product safety IEC950 EN 60950 UL 1950 CSA 22 2 No 950 EN 55 022 B and EN 50 082 1 FCC class B Acc to EU Directives 89 336 EEC EMC and 73 23 EEC product safety Service support training RemoteView is already successfully used in PRIMERGY servers as a standard component in mission critical projects RemoteView is a prerequisite for the PRIMERGY Service Pack Premium with guaranteed restore times Detailed information on training courses for service staff and administrators is available in the Fujitsu Siemens Computers Extranet internal and for partners http extranet fujitsu siemens com primergy Topic Training and Events How and where can RemoteView be obtained RemoteView and the RemoteView Service Board can be installed at factory or can be ordered separately Fujitsu Siemens Computers recommends the factory installation For more information about RemoteView and PRIMERGY products please visit us in the Internet http www primergy com The Internet address of the man
6. incl readout of the non volatile error memory Diagnosis of IDE and SCSI devices Cache and memory test Update of system BIOS and firmware for storage extensions and service processor DOS Shell for other applications Further Features and Technical Data Content of package Optional RemoteView Service Board see separate data sheet Storage medium IDE flash disk with preinstalled test and diagnostic software English Optional external power supply for the RSB Optional battery board for RSB CD for installation of the remote administrator soft ware and new installation of the IDE devices BIOS extension RomPilot for PRIMERGY 470 670 H N K400 H200 F L P C200 C150 and H250 RCM for L100 BIOS for B210 E N200 Online User Manual German English Options Modem 56kps V 90 internal and external SNP SY F1652E3 or SNP SY F1652L3 Hardware requirements PRIMERGY 470 670 20 670 40 H200 H K N400 F L P200 C200 C150 L100 H250 LAN or Modem PRIMERGY B210 E200 N800 N200 B120 only modem LAN with RSB Remote Service Board available for the following ome see separate data sheet F L P200 with BIOS V4 06 R1 01 H N K400 with BIOS V4 06 R1 12 FW 2 1 x 137 H200 with BIOS V4 06 R1 11 FW2 1 9 134 N800 with BIOS Rel 21 UB 1 03 B120 with BIOS V6 0 Rev 1014 B210 E200 and N200 with BIOS V6 0 Rev 1009 N200 or 1011 a system board with equipment revision level GS4 is
7. required for the B210 and E200 in order to be able to connect the RSB 470 with BIOS V4 06 R1 08 CFW 1 3 1 101 RSB can only be used with external power sup ply 670 20 with BIOS V4 06 R1 08 CFW 1 3 2 103 RSB can only be used with external power sup ply 670 40 with BIOS V4 06 R1 09 CFW 1 3 2 122 RSB can only be used with external power sup ply C200 with BIOS V4 06 R 1 01 L100 with BIOS V4 06 R 1 01 R01 B3F4 C150 with BIOS V4 06 R 1 00 Remote View Service Board in S60 RSB C with hardware rev 2 incl Installation kit ServerView front end 3 02 NT agent 2 54 Alarm service 1 02 RVLAN 3 02 The RSB solution can only be supplied with new orders for an S60 or as a special release LAN functionality without RSB only for the following LAN cards PRIMERGY on board Ether Express Pro 10 Combo PCI 26361 F1561 E501 L501 Fast Ether Express Pro 100 Server PCI SNP SY F2071E1 Fast EtherLink XL 3C905B TX WOL 3COM Fast EtherLink XL 3C980B TX WOL 3COM F L P200 C200 C150 PRIMERGY on board only Software requirements RemoteView runs on the server side on its own oper ating system and is therefore independent of the server operating system For communication between RSB and the system board the following ServerView agents are necessary Windows NT Windows 2000 from version 2 54 and for LINUX from version 2 50 without S60 This agents are necessary to avoid functional restr
8. ual server is http manuals fujitsu siemens com Note Depending on the server or operating system used some functions of RemoteView ServerView may differ or not be implemented For many functions of ServerView e g temperature display fan monitoring an ASIC or a service processor in the server or storage subsystem is required On systems without this hardware these func tions are not supported Electromagnetic compatibility CE certification Published by Fujitsu Siemens Computers Product Marketing PRIMERGY Enterprise Products PRIMERGY Servers All rights including rights created by patent grant or registration of a utility model or design are reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trade names or trademarks of their respective manufacturers Company stamp World Wide Web http www primergy com http extranet fujitsu siemens com primergy Copyright Fujitsu Siemens Computers GmbH V2 9 April 2002