User`s Manual of Sperm Collector SW-3701
Contents
1. P SWE Jiangsu Sanwe Medical Science and Technology Co ltd User s ua User s Manual of Sperm Collector SW 3701 Wise Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Introduction Dear consumers Welcome to use Sanwe Series Sperm Collector and Analyzer It is our great honor that our Sanwe Series Sperm Collector and Analyzer can get your trust The specification is to help you use this product rightly including the characteristics structural characteristics technical features keypad operation function use help simple troubleshooting maintenance attentions and something else of this equipment Before the installation and use of this product please make sure to read all of the information distributed with the equipment carefully especially the safety information and attentions referred by other terms This will help you make better use of this product In addition if you have any questions in the process of using please call us email us or visit the Sanwe web site we will serve you wholeheartedly Disclaimer Note The description of this specification does not stand for anything of the product specifications and software and hardware configuration As to the product specifications and configuration information please refer to the relevant agreements of the products packing notes or consult the distributor In the preparation process of this manual we have sought to correct and comp
2. advised of the possibility of such damages which is the same 4 The failure that 1s made by installing the software or hardware not attached with this equipment and not caused by Sanwe product itself 5 The failures made by using in the environment not provided in this specification or by wrong operation methods 6 The cases that force majeure factors leading to product damage You can call the service hotline or visit the website of Sanwe for the related information about this product Service Hotline 0516 82308605 82308606 Sanwe Website http www vvvmc com Symbol explanations label important information when using our products attention they stand for the prompt message which may lead to product failure property damage or personal injury 5 Danger high voltage A Attention Check the attachment a Can not be dropped in dustbin 1 BF type equipment j j Up 5 Fragile objects i i Defending rain KK Defending Sunshine Stacking Wim Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Content latodun Aae aoe alc l COME I a a eee E E CHapier I o Unna ye are E oes ee R Chapter 2 Mechanical Features and Operating Principles 5 ta Mechanical Cavulcs asasi eee ees Se oS ee 5 24 Operating Principles se a Se SS eee Chapter gt Technical Feature ses or Srata a aries ere ieesene ree eee sane G Chapter 4 operational 1low Charlot e sess ne esse ee ede ees Chapter 5 Ins
3. related wasters in the process should be handled according to the local laws 1 7 Products Features and Classification Safety category I Subordinate type protection type B part Service voltage 220V 22V SOHz 1Hz Wim Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Chapter Two Operating Principles and Mechanical Features Structure Features 1 Basic Configuration Sperm Collector 1set including DVD 2 Accessories Power line 1 pc Packing information 1 set Operating Principles It can simulate vaginal environment through massage stimulation reciprocating motion stimulation multimedia video stimulation and achieve the good effect Whole Map SW 370 1 HEM Wie Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Chapter Three Technical Features Power supply 220V 22V 50Hz 1Hz Basic Parameter 1 Massage No 70 90 Minute 2 Reciprocating motion No 0 150 minute can adjustable 3 Reciprocating motion journey 45mm 4 Going up and down range 50mm Input power SW 3701Type lt 50 VA Chapter Four operational flowchart Explainthe process of sperm collecting and eliminate their psychological barriers Interrogation and input information Prepare all the accessories and help patient collect sperm Guide the patient Help patient sit after finishing Input data and clear up the things 1 2 3 4 5 6 Wie Jiangsu Sanwe Medical
4. Science and Technology Co ltd User s manual Chapter Five Installation After opening the box in accordance with the packing list check devices the host and accessories should be in line with the packing list and read the instructions carefully to familiarize the method of application Take out of the host and accessories Inspect power supply of the apparatus to ensure one of the ends of the power cord be inserted the back panel of the host marked 220V 50Hz and the other one connect with special power wiring board within the scope of prescriptive power Inspect the connection of the apparatus among the various parts and then switch on the power after ensuring right connection When the installation personnel installs the equipment it should be placed on a clean and ventilated room dry and clean environment avoiding together with chemicals and electromagnetic and strong electrical field and the equipment installation location should be convenient for operating Chapter Six Instructions Adjusting the sperm barrel height into a appropriate position Watch DVD disc before using it DVD discs are on the rear LCD screen In the shutdown case just gently push up to replace the LCD screen discs Users stand wearing a condom on the penis before using with a little human lubricant on the condom Put the penis into sperm tube turn on the switch of the master power supply and adjust the pressure regulator knob to the appropriate massag
5. ation We should prevent sleeting make the device wet and mechanical collision extrusion It is forbidden delivering with corrosive goods Storage The packaged instruments should be stored in dry ventilation no corrosive substances interior 1 5 Required Safety Regulations 1 System safety requirements accord with GB9706 1 2007 Medical Electric Equipment the First Part general requirements for safety 2 The environmental test of system is in accordance with the requirements of environment for climate test Group II and environment for mechanical test Group II of Environmental Requirements and Test Methods for Medical Electrical Equipment GB T14710 93 3 Indoor power supply system in system studio should be standard three core power outlet whose protection ground junction terminal is connected with protective ground conductor of the power supply system If there is no protection ground junction terminal connecting with the protective ground conductor of the power supply system in the power outlet the consumer should use a metal wire with the cross sectional area of no less than 1 0 mm one end connected with a protective earthing termination column the other end with the land Note The consumer should operate the suppression of ground wire in accordance with related standard or under the guidance of the experienced electrician 1 6 Requirements for Environment Protection Equipment and accessories in its life end and the
6. e efforts and then begin to massage the penis After the penile erection turn on the speed adjustment knob which can change motion speed For some time after the completion of successfully fetching sperm please turn off the speed adjustment knob and the master switch Note 1 Avoid overlapping infection each user has a set of tube and tube cover when they are inspected The tube and tube cover are disposable consumables we can t throw them into the dustbin directly we should cast away them after destroing them Please purchase the consumers from our company 2 Because the improper forcibly of the user the Instruments with power off protection The device can recovery by itself about 2 minutes Please don t operate or touch the machine in the period of power off protection If the device can t recovery in 2 minutes please restart it Wise Jiangsu Sanwe Medical Science and Technology Co ltd User s manual The Note of the Equipment Application o There are strong electricity in the equipment do not open it by yourself elf power fails suddenly during operation start up power again and the interval should be no less than three minutes or no response Apparatus should be placed on clean and ventilated room needing dry and clean environment avoiding putting chemicals electrical electromagnetic and strong electricity with the equipment together Do not move or shake the equipment when it on position e Avoid fre
7. lete the content but still can not guarantee that there are no errors and omissions in the manual constantly optimize and improve their products and services for which we reserves the right to modify the description of the products described in this manual and the content at any time without notice If you find any inconsistencies between the manual description and the actual situation in the course of using this specification please call us or visit our Sanwe web site for information in the case of you needing up to date information or having any questions and ideas Limited guarantee The product attaches standard service commitment guarantee content so we will offer you service according to guarantee content Sanwe Company doesn t offer service beyond the standard service commitment In such condition you should ask the organization or individuals offer you service support according to their commitment 44 SME Jiangsu Sanwe Medical Science and Technology Co ltd User s manual In the fullest extent permitted by law we will have no need to be responsible for any of the following under any circumstances 1 The third party claim against you except physical death injury real estate and related compensation for tangible property damage 2 The losing or damage of your record or data 3 Special consequential or indirect damages or any sequential economic losses including profit and loss of savings even if our company has been
8. nd specialized staff for maintenance in 12 months once If necessary the company can provide circuit diagrams and component list In the warranty period failures caused by product quality maintenance 1s free of charge Beyond the guarantee repair is for all of the life The following causes of failure are not in the scope of guarantee a Unauthorized disassembly and modification b Inadvertently tempering or falling c Lack of reasonable maintenance or environmental requirements d The operation not in accordance with the requirements of this manual e Without the permission of the company to repair f Force majeure No guarantee for consumption and fragile goods No guarantee if unable to offer quality books of the company Please directly contact the agents if purchasing equipment from the agents of the company 4 SME Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Jiangsu Sanwe Medical Science and Technology Co ltd Address Sanwe Science and Technology Park Zhujiang Road Tongshan Economic amp Technology Development Zone Xuzhou City Jiangsu Province Of China Tel 0516 82308605 Fax 0516 82308606 Mobile 18652257753 Postal Code 221116 After sales service Tel 0516 82308605 After sales service Fax 0516 82308606 E mail salesOS sanwegroup com Website http www vvvmc com
9. quent switches or easily damaged When equipment is not in use shut down the power unplug the outside power and cover cloth cover A long time out of use clean it put it on the box and regularly open the electricity to run Generally once a month Equipment packaged by paper wooden box should be placed THN avoid the r atc Sa F g 3 l c l EJ l l damp T collision extrusion m and sunshine in transportation It can be transported by air road rail and ship eln the failure of equipment do not open the case by yourself and get in touch with the maintenance company for repairs Note Chapter Seven Maintenance eCheck power supply frequently if the voltage exceeds the adaptation scope of equipment AC 198V 242V no using the boot otherwise regulating power supply eCheck power line the equipment regularly if damaged or fractured it should be replaced immediately e Unplug the power cord before cleaning the outer surface of equipment Wipe it with cotton wool and toothpaste but not alcohol cleaners and fungicides eAfter moving equipment check whether there is loose connections among components If loosening it should be well connected eWhen the equipment fails invite the specialized personnel or contact the company Wim Jiangsu Sanwe Medical Science and Technology Co ltd User s manual Chapter Eight After service eProducts sold by the company is guaranteed for 18 months The company will se
10. tructions of the devico 4 Se Sr eee see imam er nee sien ernie aes Chapter CAnnouncemenist eee ne ie sissies ears eae esos Seen Napter Vidi dane S 9 sas Sie Sea eee 9 Chapter S Alter sery 1CG Ss s9 4568 ii ests en ee een aes Chapter One Summary 1 1 Product Features SW 3700 Series Sperm Collector and Analyzer combines with modern computer technology automatic control technology acting upon the human penis through massage twitching and other ways and collecting sperm fast Then we take advantage of biological microscope computer imaging technology and the data processing of software we can analysis sperm scientifically which make it a perfect sperm collect equipment SW 3701 has the function of sperm collection but no the function of analyzing and printing the report of the results 1 2 Main Application and Applicable Scope The device is used for the sperm sample collecting 1 3 Normal Work Conditions 1 temperature 22 40 C 2 relative humidity lt 80 3 atmospheric pressure 86Kpa 106 Kpa 4 service voltage AC 220V 22V 50Hz 1Hz 5 Instruments should be far away from the strong magnetic field Wie Jiangsu Sanwe Medical Science and Technology Co ltd User s manual 1 4 Transportation and Storage Conditions 1 temperature 22 40 C 2 relative humidity lt 80 3 atmospheric pressure 86Kpa 106 Kpa Transportation Packed device can be delivered by generally traffic tools or by contrast transport