RCN-T-36W-E Infra Red Kit for 4 Way Cassettes Installation
Contents
1. s manual attached on the air conditioner Auto mode operation setting backup button Backup button A Backup button is provided on the receiver Even when the operation from the wireless remote controller is not possible due to flat batteries controller lost or controller failure still it possible to operate as temporary means Press the button directly when operating it 1 The air conditioner starts the operation with the condition of Auto mode 23 C of set point High fan speed and horizontal louver position 2 The air conditioner stops the operation when the button is pressed when in operation Cooling test run operation After safety confirmation turn on the power Transmit a cooling operation command with wireless remote controller while the backup button on the receiver is pressed i the backup button on the receiver is pressed during a test run it will end the test run i you cannot operate the unit properly during a test run please check by consulting with inspection guides on the wiring diagram of outdoor units How to read the two digit display On the receiver of a wireless kit a two digit 7 segment display is provided 1 An indication will be displayed for one hour after power on 2 An indication will be displayed for 3 5 seconds after transmitting a STOP command from the wireless remote controller or the operation of the backup button to s
2. the package Accessories Please make sure that you have all of the following accessories Remote controller Receiver holder Wireless remote controller Wood screw for holder Parts set AAA dry cell battery RO3 How to install the receiver The receiver can be installed by replacing with a corner panel on the applicable decorative panel Preparation before installation Attach the decorative panel onto the air conditioner according to the installation manual for the panel Remove the air return grille Remove a corner panel located on the refrigerant pipes side Remove three screws and detach the cover indicated as shadowed area from the control box of the air conditioner Refrigerant pipes Drain pipe Setting on site 10 e PAC DB 142 PJF012D010 lt To change the settings gt Remove the cover by unscrewing two screws from the back of receiver Change the setting by the switch on PCB Au OFF 3 4 settings Screws Receiver Backside l J Lx Cover packside O When SW1 is turned to OFF position change the corresponding remote controller setting as follows How to change th
3. 3 1 2 FDT Series RCN T 36W E A WARNING Fasten the wiring to the terminal securely and hold the cable securely so as not to apply unexpected stress on the terminal 6 Loose connection or hold will cause abnormal heat generation or fire Make sure the power supply is turned off when electric wiring work Otherwise electric shock malfunction and improper running may occur A CAUTION DO NOT install the wireless kit at the following places in order to avoid malfunction 1 Places exposed to direct sunlight 2 Places near heat devices 3 High humidity places 4 Hot surface or cold surface enough to generate condensation 5 Places exposed to oil mist or steam directly 6 Uneven surface 7 Places affected by the direct airflow of the 8 Places where the receiver is influenced by the fluorescent lamp especially inverter type or sunlight 9 Places where the receiver is affected by infrared rays of any other communication devices 10 Places where some object may obstruct the communication with the remote controller AC unit DO NOT leave the wireless kit without the cover In case the cover needs to be detached protect the receiver with a packaging box or bag in order to keep it away from water and dust 9S Instruct the customer how to operate it correctly referring to the instruction manual For the installation method of the air conditioner itself refer to the installation manual enclosed in
4. As for the size refer to the following note For Packaged air conditioner series set the indoor unit address with SW2 on the indoor unit PCB from 0 to F so as not to duplicate Restrictions on the thickness and length of wire Maximun total extension 600m Standard Within 100m x 0 3 mm Within 200m x 0 5 mm Within 300m x 0 75mm Within 400m x 1 25mm Within 600m x 2 0 mm Terminal block OO gy Indoor unit 16 Address 1 Address F Indoor unit 1 Indoor unit 2 Address 0 Receiver f Remote controller For VRF series set the indoor unit address with SW1 SW2 and SW5 2 on the indoor unit PCB from 000 to 127 so as not to duplicate Master Slave setting when using plural remote controllers Up to two receivers can be installed in one indoor unit group When two receivers are used it is necessary for a receiver to turn OFF SW2 on the receiver PCB to set it as slave For the method of switching please see Setting on site in the section of Oe ACR CRUCE in this manual 10 e PAC DB 142 Wireless remote controller s operable area Standard reachable area of the signal condition Illuminance at the receiver 300lux when no lighting is installed within 1m of the receiver in an ordinary office Ceiling surface Reachable area tp 0 Im 2m 3m 4m Correlation betwe
5. e remote controller setting Pressing ACL and AIR FLOW button at the same time or inserting the batteries with pressing AIR FLOW button will customize the signal X When the batteries are removed the setting will return to the default setting Please make sure to reset it when the batteries are replaced Oon orr s FAN SPEED AIRFLOW IMER 6 J 6 Caution Instruct the customer to set the mentioned above when replacing the batteries How to set is also mentioned in the users manual attached on the air conditioner Radio interference prevention mode Installation of the receiver Loosen the bolts which fix the panel and make a gap between the panel and the indoor unit Put the wiring of the receiver through the opening Put the wiring on the notch on the control box so as not to be pinched by the control box and lid as shown below Connect the wiring to the terminal block provided in the control box Non polarized Attach the receiver to the panel according to the panel installation manual Fix the wiring with the clamp so that the wiring do not contact the edge of control box s metal sheet Reattach the control box lid with 3 screws removed X Note Make sure the wires not to be pinched by any other parts like panel control box and indoor unit PCB on the receiver has the following switches to set the functions Default setting is shown Termi
6. en illuminance at the receiver and reachable area of the signal in a plain view The drawing in the right shows the The receivable area of the signal when the illuminance at the receiver is 300lux correlation between the reachable area of the signal and illuminance at the receiver when the remote controller is operated at 1 1m high under the condition of ceiling height of 2 5m When the illuminance becomes double the area is narrowed down to two thirds The receivable area of the signal when the illuminance at the receiver is 600lux Installation tips when several receivers are installed close Minimum distance between the indoor units which can avoid cross communication is 5m under the condition of 300lux of illuminance at the receiver When no lighting is installed within 1m of the receiver in an ordinary office VRF system except heat recovery 3 pipe systems cannot be operated in Auto mode Make sure to set the remote controller for the models so as not to be able to choose Auto mode Pushing ACL and MODE button at the same time or inserting the PA spero NOP un row batteries with pressing MODE button will make auto mode operation X When the batteries are removed the setting will return to the default setting Auto mode is valid FILTER MODE Instruct the customer to set the mentioned above when replacing the batteries How to set is also mentioned in the user
7. nal block in the indoor with mark swi Customized signal setting to avoid mixed communication ON Normal OFF Remote Receiver master slave setting ON Master OFF Slave Buzzer valid Invalid ON Valid OFF Invalid Auto restart ON Valid OFF Invalid unit control box HEI i xX Y A ut 276 3 Remote controller Installation of the controller holder Caution DO NOT install it on the following places 4 Hot surface or cold surface enough to generate 1 Places exposed to direct sunlight condensation 2 Places near heat devices 5 Places exposed to oil mist or steam directly 3 High humidity places 6 Uneven surface Wood screw ieee Installation tips for the remote controller holder Adjust and keep the holder upright Tighten the screw to the end to avoid scratching the remote controller DO NOT attach the holder on plaster wall Holder for remote controller How to insert batteries Detach the back lid Insert the batteries two AAA batteries Reattach the back lid Ensure the correct polarity when inserting Control plural indoor units with one remote controller Up to 16 indoor units can be connected Connect the XY terminal with 2 core wire
8. top the unit 3 An indication appearing in 1 or 2 above will go off as soon as the unit starts operation 4 When there are no error records to indicate addresses of all the connected units are displayed 5 When there are some error records remaining the error records are displayed 6 Error records can be cleared by transmitting a STOP command from the wireless remote controller while the backup button is pressed a2 Po
Download Pdf Manuals
Related Search
Related Contents
Harbor Freight Tools 18 Volt 3/8 in. Cordless Drill/Driver With Keyless Chuck, 21 Clutch Settings Product manual システムバス『広ろ美ろ浴室』〔MR工法〕 User Manual 20111021 Lochinvar INS7141 Water System User Manual Manual de Instruções Máquinas de Costura 457A105 eMPPT30 series - YSmart Technology Co.,Ltd NOUVELLES HOSP` User Manual PAX2D – 1/8 DIN Digital Input Copyright © All rights reserved.